TEHNIČKO UPUTSTVO / TECHNICAL MANUAL TEHNIČNA NAVODILA za montažu, upotrebu i održavanje akumulacijskog spremnika / for instalation, use and maintenance of the water accumulation tanks / za montažo, uporabo in vzdrževanje akumulacijskega rezervoarja TUCAS1-08/2017 CAS; -S; -B; -BS HEATING TECHNIQUE Centrometal d.o.o. - Glavna 12, 40306 Macinec, Croatia, tel: 040 372 600, fax: 040 372 611 HR EN SLO

CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

TEHNIČKO UPUTSTVO / TECHNICAL MANUALTEHNIČNA NAVODILA

za montažu, upotrebu i održavanje akumulacijskog spremnika /for instalation, use and maintenance of the water accumulation tanks /za montažo, uporabo in vzdrževanje akumulacijskega rezervoarja

TUCAS1-08/2017

CAS; -S; -B; -BS

HEATING TECHNIQUE

Centrometal d.o.o. - Glavna 12, 40306 Macinec, Croatia, tel: 040 372 600, fax: 040 372 611

HR EN SLO

Page 2: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

2 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Dimenzije i osnovni dijelovi akumulacijskog spremnika

CAS CAS-S

Termometar

Termometar

Toplinskaizolacija

Mjesto za temp. osjetnik

Mjesto za temp. osjetnik

F

DC

B

A

Priključak (unut.nav.) *

Termometar

Termometar

Postolje spremnika

Priključak (unut.nav.) *

Priključak (unut.nav.) *

Mjesto za temp. osjetnik

Mjesto za temp. osjetnik

Priključak (unut.nav.) *

E

Tijelo spremnika

Cijevni izmjenjivač(umutarnji navoj 5/4")

CAS CAS-S

90

°

90

°

G

H

Priključak (unut.nav.) *

Priključak (unutarnji navoj) *

Mjesto za temp. osjetnik

Cijevni izmjenjivač(umutarnji navoj 5/4")

Priključak (unutarnji navoj) *

Priključak 1/2" za termometar

Cijevni izmjenjivač(unutarnji navoj 5/4")

Cijevni izmjenjivač(unutarnji navoj 5/4")

Priključak (unutarnji navoj) *

* - Priključak 6/4" (CAS 501 - 2001), 2" (CAS 3001 - 4001) (unutarnji navoj)

HR

Page 3: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

3Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Dimenzije i osnovni dijelovi akumulacijskog spremnika

CAS-BS

90

°

90

°

Priključak 1/2" za termometar

Otvor za osjetnik

Cirkulacija (unutarnji navoj 3/4")

Topla sanitarna voda(unutarnji navoj 3/4")

Priključak 6/4’’(unut.nav.)

Hladna sanitarna voda(unutarnji navoj 3/4")

Cijevni izmjenjivač(umutarnji navoj 5/4")

Mjesto za temp. osjetnik

Hladna sanitarna voda(unutarnji navoj 3/4")

Topla sanitarna voda(unutarnji navoj 3/4")

Priključak 6/4’’(unut.nav.)

Priključak 6/4”(unutarnji navoj)

Cirkulacija(unutarnji navoj 3/4")

CAS-B

CAS-BSCAS-B

Termometar

Termometar

Termometar

Mjesto za temp. osjetnik

Mjesto za temp. osjetnik

Cijevniizmjenivač(unutarnji

navoj 5/4'')

Inox bojler PTV

Priključak 6/4” (unutarnji navoj)

Priključak 6/4’’(unut.nav.)

Toplinskaizolacija

Termometar

Priključak 6/4’’(unut.nav.)

Priključak 6/4’’(unut.nav.)

Mjesto za temp. osjetnik

Priključak 6/4’’(unut.nav.)

Mjesto za temp. osjetnik

Postolje spremnika

Cijevni izmjenjivač(unutarnji navoj 5/4")

Cijevni izmjenjivač(unutarnji navoj 5/4")

Poklopac otvora zareviziju PTV

Poklopac otvora zareviziju PTV

Tijelo spremnika

Otvor za osjetnik

HR

Page 4: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

4 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Tehnički podaci

Tip1001 2001501 801

0,8 1,0 2,0 3,0 4,0

2

3

4

5

6

8

10

20

30

40

Slika 1. Otpor protoka CAS

Količina protoka u m /h3

Otp

or

pro

tok

a u

mb

ar

CAS1001501 801

CAS-S1001501 801

CAS-BS1501

Volumen

Promjer tijela sprem. G

Vanjski promjer H

Ukupna visina F

Priključci

Max. radni tlak

Max. radna temp.

Min. visina prostorije

Masa pr. tijela spr.

Masa praznog spremnika

Volumen sprem. PTV

Max. radni tlak spr. PTV

Priključci PTV

Ogrj. površina spirale

Volumen ogrj. spirale

Toplinska izolacija

Visina A

Visina B

Visina C

Visina D

Visina E

(lit.)(mm)(mm)(mm)

(R)(bar)(°C)

(mm)(kg)(kg)(lit.)

(bar)(R)

2(m )(lit.)

(mm)(mm)(mm)(mm)(mm)(mm)

475650850

16706/4''

3100

18707584-----

100230610

-10001380

740790990

17506/4''

3100

195099112

-----

100320670

-10201370

940790990

21506/4''

3100

2350149164

-----

100320800

-12901770

21801200140021806/4''

3100

2435245265

-----

100335800

-12701735

475650850

16706/4''

3100

1870100109

---

1,910,5100230610630

10001380

940790990

21506/4''

3100

2350185201

---

3,217,5100320800970

12901770

740790990

17506/4''

3100

1950135150

---

2,614

100320670870

10201370

475650850

16706/4''

3100

1870120129125

63/4"1,9

10,5100230610630

10001380

740790990

17506/4''

3100

1950175190170

63/4"2,614

100320670870

10201370

940790990

21506/4''

3100

2350215230170

63/4"3,2

17,5100320800970

12901770

14501000120021006/4''

3100

2300185204

-----

100320785

-12551720

3001

2960125014502695

2"3

1002915321

-----

100370

1000-

16302260

4001

3820140016002790

2"3

1003015380

-----

100420

1050-

16802310

501

CAS-B

801 1001

940790990

21506/4''

3100

2350176191170

63/4"

--

100320800

-12901770

740790990

17506/4''

3100

1950137150170

63/4"

--

100320670

-10201370

475650850

16706/4''

3100

1870105114125

63/4"

--

100230610

-10001380

HR

Page 5: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

27Tehničko uputstvo CentroMini 5Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

1.0. PREDSTAVLJANJE

Predstavljanje, namjena, stanje kod isporuke

Akumulacijski spremnici CAS, CAS-B, CAS-S i CAS-BS tvrtke Centrometal d.o.o. proizvedeni su najsuvremenijom tehnologijom zavarivanja od kvalitetnog čelika. Izrađuju se u 7 volumena (475, 740, 940, 1450, 2180, 2960 i 3820 litara) i 4 izvedbe: kao akumulacijski spremnik (CAS), sa ugrađenim inox bojlerom za pripremu potrošne tople vode (CAS-B), sa ugrađenim cijevnim izmjenjivačem za spajanje solarnih kolektora (CAS-S) te sa ugrađenim inox bojlerom i cijevnim izmjenjivačem (CAS-BS). Pridržavanjem tehničkih uputa, koja pojašnjavaju konstrukciju, način rada, priključivanje i održavanje akumulacijskog spremnika, zagarantiran Vam je nesmetan i ekonomičan rad proizvoda.

Akumulacijski spremnici CAS, CAS-B, CAS-S i CAS-BS namijenjeni su akumuliranju energije (npr. u sustavima centralnog grijanja uz kotlove na kruto gorivo radi akumuliranja toplinske energije) te osiguravaju ekonomičniji i efikasniji rad samog sustava u koji su ugrađeni. Više izvedbi ovih spremnika omogućuju istodobno korištenje više obnovljivih izvora energije, što ih čini ekološki i energetski vrlo prihvatljivim.

2.0. NAMJENA

3.0. STANJE KOD ISPORUKE

Akumulacijski spremnici CAS, CAS-B, CAS-S i CAS-BS se zbog lakšeg transporta i lakšeg postavljanja ne isporučuju s montiranom toplinskom izolacijom već zasebno:- tijelo akumulacijskog spremnika na drvenoj paleti- toplinska izolacija upakirana u zaštitnu PVC foliju- termometar (4 kom.), tuljac za termometar (4 kom.), rozete (crne) upakirano u PVC vrečicu

HR

Page 6: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

6 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

4.0. POSTAVLJANJE

Akumulacijski spremnici CAS, CAS-B, CAS-S i CAS-BS dolaze isporučeni na drvenoj paleti. Prije postavljanja akumulacijskog spremnika na predviđeno mjesto u kotlovnici potrebno ga je skinuti s drvene palete. Postavljanje i sastavljanje akumulacijskog spremnika te ugradnja dodatne opreme na spremnik mora biti izvedeno od strane stučne osobe. Akumulacijski spremnik je potrebno postaviti na horizontalnu čvrstu podlogu predviđenu za opterećenje koje uzrokuje masa punog spremnika. Kotlovnica mora biti sigurna od smrzavanja. Spremnik je potrebno postaviti tako da je njegovo spajanje moguće korektno izvesti, a da ujedno bude omogućeno nadziranje u toku rada. Za montažu toplinske izolacije na akumulacijski spremnik vidi ‘’Tehničko uputstvo za montažu toplinske izolacije akumulacijskog spremnika CAS; -S; -B; -BS’’ koje se isporučuje sa spremnikom (uz jamstveni list).

6.0. PRIKLJUČENJE AKUMULACIJSKOG SPREMNIKA NA INSTALACIJU

CENTRALNOG GRIJANJA

Priključenje spremnika na instalaciju centralnog grijanja izvesti prema preporukama i shemi proizvođača kotla (izvora topline), a u skladu sa ovim tehničkim uputama i pravilima struke.

5.0. NATPISNA PLOČICA S OSNOVNIM PODACIMA O PROIZVODU

Max. radni pretlak sprem. (bar):

Volumen spremnika (lit.):

Tvornički broj:

Godina proizvodnje:

Tip sprem.: CAS

2010.

d.o.o.40306 MACINEC, GLAVNA 12 - HRVATSKA

Proizvođač: Centrometal d.o.o.

AKUMULACIJSKI SPREMNIK

Volumen spremnika PTV (lit.):

Max. radni pretl. sp. PTV (bar):

Masa spremnika (kg):

Max. radni pretlak sprem. (bar):

Volumen spremnika (lit.):

Tvornički broj:

Godina proizvodnje:

Tip sprem.: CAS

2010.

d.o.o.40306 MACINEC, GLAVNA 12 - HRVATSKA

Proizvođač: Centrometal d.o.o.

AKUMULACIJSKI SPREMNIK

Volumen spremnika PTV (lit.):

Max. radni pretl. sp. PTV (bar):

Masa spremnika (kg):

Natpisna p loč ica akumulaci jskog spremnika nalazi se pričvršćena na njegovo postolje i prekrivena je toplinskom izolacijom. Kako bi se došlo do natpisne pločice potrebno je povući patentni zatvarač toplinske izolacije prema gore (otvoriti) cca. 50 cm te je razmaknuti (vidi sliku 2.).

Slika 2. Položaj natpisne pločice na akumulacijskom spremniku

cc

a.

50

cm

Postavljanje, natpisna pločica, priključenje na instalaciju grijanjaHR

Page 7: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Shema 1. Primjer ugradnje akumulacijskog spremnika CAS-BS na vodovodnu instalaciju

1 - Akumulacijski spremnik CAS-B/CAS-BS2 - Ekspanzijska posuda za sanitarnu vodu3 - Sigurnosni ventil s tlakom otvaranja 6 bar4 - Nepovratni ventil5 - Regulator tlaka6 - Zaporni ventil7 - Topla sanitarna voda8 - Cirkulacija9 - Hladna sanitarna voda10 - 3-putni termostatski mješajući ventil za sanitarnu vodu11 - Otvor za osjetnik12 - Priključak 6/4" (unutarnji navoj)

* potrebno je ugraditi ako je tlak ulazne vode veći od 4 bar-a

*

**

** preporuka

90°

9

7

10**

Ulaz hladne sanitarne vode

2

4 *5 6

1

8

11

12 11

7 9

8

12

3

27Tehničko uputstvo CentroMini 7Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Priključenje na vodovodnu instalaciju

7.0. PRIKLJUČENJE AKUMULACIJSKOG SPREMNIKA CAS-B I CAS-BS

NA VODOVODNU INSTALACIJU

Priključenje inox bojlera u akumulacijskom spremniku CAS-B/CAS-BS na vodovodnu instalaciju mora se izvesti prema važećim tehničkim normama, od strane stručne osobe (Shema 1.). Dovod hladne sanitarne vode priključuje se na priključak (9) (Shema 1.) (kolčak 3/4''), a priključak (7) (Shema 1.) (kolčak 3/4'') služi za odvod tople sanitarne vode. Priključak cirkulacijskog voda (8) (kolčak 3/4'') nalazi se s desne strane priključka hladne vode.Na ulaz hladne sanitarne vode u bojler obavezna je ugradnja: - ekspanzijske posude za sanitarnu vodu; - sigurnosnog ventila sa tlakom otvaranja 6 bar-a; - redukcijskog ventila koji smanjuje tlak ulazne hladne sanitarne vode na 4 bar-a (ukoliko je njezin tlak veći); - nepovratnog ventila.

HR

Page 8: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Potrebno je provesti (prekontrolirati, ako su već izvedene) sve radnje u skladu sa točkama 1.0. do 7.0. ovih uputa.

Maksimalni radni tlak u spremniku spojenom na instalaciju centralnog grijanja mora biti ograničen ugrađenim sigurnosnim ventilom s tlakom otvaranja max. 3 bar-a.

8.0. PUŠTANJE U POGON

8.1. PUŠTANJE U POGON - CAS / -S 501, CAS / -S 801, CAS / -S 1001, CAS / -S 1501,

CAS / -S 2001, CAS - 3001, CAS - 4001

8.2. PUŠTANJE U POGON - CAS-B / -BS 501, CAS-B / -BS 801, CAS-B / -BS 1001,

CAS-B / -BS 1501, CAS-B / -BS 2001

Potrebno je provesti (prekontrolirati, ako su već izvedene) sve radnje u skladu sa točkama 1.0. do 7.0. ovih uputa.

Maksimalni radni tlak u spremniku spojenom na instalaciju centralnog grijanja mora biti ograničen ugrađenim sigurnosnim ventilom s tlakom otvaranja max. 3 bar-a.

Maksimalni radni tlak u inox bojleru za sanitarnu vodu spojenom na vodovodnu instalaciju mora biti ograničen ugrađenim sigurnosnim ventilom s tlakom otvaranja max. 6 bar-a.

Prije punjenja akumulacijskog spremnika izvedbe CAS-B i CAS-BS kotlovskom vodom (strana sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a.

8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Akumulacijski spremnik CAS, CAS-B, CAS-S i CAS-BS čistiti prema potrebi pražnjenjem posude. Prije svakog punjenja akumulacijskog spremnika izvedbe CAS-B i CAS-BS kotlovskom vodom (strana sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. Iznos minimalnog tlaka od 1,5 bar-a u inox bojleru PTV (sanitarna voda) održavati i tokom rada.

9.0. KORIŠTENJE, ČIŠĆENJE I ODRŽAVANJE

Puštanje u pogon, korištenje, čišćenje i održavanjeHR

Page 9: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

27Tehničko uputstvo CentroMini 9Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Karakteristike akumulacijskih spremnika

10.0. KARAKTERISTIKE AKUMULACIJSKIH SPREMNIKA CAS, CAS-B, CAS-S i CAS-BS

Izrađeni su iz atestiranog čeličnog lima u skladu s normom ISO 9001/2000.Dobra toplinska izolacija (100 mm) obložena oblogom od skaja.Moguće povezivanje više spremnika zajedno u svrhu povećanja ukupne akumulacije.Izrađuju se u 7 volumena i 4 izvedbe:- CAS 501 (475 litara), CAS 801 (740 litara), CAS 1001 (940 litara), CAS 1501 (1450 litara) i CAS 2001 (2160 litara), CAS 3001 (2960 litara) i CAS 4001 (3820 litara) - akumulacijski spremnik- CAS-S 501 (475 litara), CAS-S 801 (740 litara), CAS-S 1001 (940 litara) - akumul. spremnik sa cijevnim izmjenjivačem- CAS-B 501 (475 litara), CAS-B 801 (740 litara), CAS-B 1001 (940 litara) - akumul. spremnik sa inox bojlerom za san. vodu- CAS-BS 501 (475 litara), CAS-BS 801 (740 litara), CAS-BS 1001 (940 litara) - akumul. sprem. sa inox bojlerom i cijev. izmjenj.

HR

Page 10: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

10 Technical manual CAS, CAS-B, CAS-S i CAS-BS

F

DC

B

A

E

Dimensions and the basic parts of the accumulation tank

Connection (female thread) *

Accumulation tank body

Connection (female thread) *

Tube for temp.sensor

Connection (female thread) *

Tube exchanger(female thread 5/4'')

Connection (female thread) *

Tube exchanger(female thread 5/4'')

Connection (female thread)*

Accumulation tank foundation

Tube exchanger(female thread 5/4'')

Thermal insulation

Thermometer

Thermometer

Thermometer

Thermometer

Tube for temp.sensor

Tube for temp.sensor

Tube for temp.sensor

CAS CAS-S

CAS CAS-S

90

°

90

°

G

H

Connection 1/2'' for thermometer

Connection (female thread)*

Connection (female thread)*

Tube exchanger(female thread 5/4'')

Connection (female thread)*

Tube for temp.sensor

* Connection 6/4'' (cas 501- 2001), 2" (CAS 3001- 4001) (female thread)

EN

Page 11: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

11Technical manual CAS, CAS-B, CAS-S i CAS-BS

Dimensions and the basic parts of the accumulation tank

CAS-BSCAS-B

Thermometer

Thermal insulation

Accumulation tank body

Steinless steel DHW tank

Connection 6/4'' (female thread)

Connection 6/4'' (female thread)

Tube for temp.sensor

Connection 6/4''(female thread)

Tube exchanger(female thread 5/4'')

Connection 6/4''(female thread)

Tube exchanger(female thread 5/4'')

Connection 6/4''(female thread)

Accumulation tank foundation

Tube exchanger(female thread 5/4'')

Thermometer

Thermometer

Thermometer

Tube for temp.sensor

Tube for temp.sensor

Tube for temp.sensor

CAS-BS

90

°

90

°

CAS-B

Visual control opening cover DHW

Connection 1/2'' for thermometer

Opening for sensor Circulation(female thread 3/4'')

Connection 6/4'' (female thread)

Tube exchanger(female thread 5/4'')

Connection 6/4''(female thread)

Connection 6/4'' (female thread)Circulation(female thread 3/4'')

Visual controlopening cover DHW

Opening for sensor

Cold sanitary water(female thread 3/4'')

Hot sanitary water(female thread 3/4'')

Hot sanitary water(female thread 3/4'')

Cold sanitary water(female thread 3/4'')

Tube for temp.sensor

EN

Page 12: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

12 Technical manual CAS, CAS-B, CAS-S i CAS-BS

Technical data

0,8 1,0 2,0 3,0 4,0

2

3

4

5

6

8

10

20

30

40

Pict. 1. Flow resistance of CAS

Flo

w r

es

ista

nc

e i

n m

ba

r

3Amount of flow in m /h

Tip1001 2001501 801

CAS

1001501 801

CAS-S

1001501 801

CAS-BS

1501

Volume

Tank body diameter G

Outer diameter H

Total height F

Connections

Max. operating press.

Max. operating temp.

Min. height of the room

Empty acc. body weight

Empty acc. tank weight

DHW tank capacity

Max. oper. press. DHW tank

DHW connections

Heat exchanger surface

Heat exchanger volume

Thermal insulation

Height A

Height B

Height C

Height D

Height E

(lit.)

(mm)

(mm)

(mm)

(R)

(bar)

(°C)

(mm)

(kg)

(kg)

(lit.)

(bar)

(R)2

(m )

(lit.)

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

475650850

16706/4''

3100

18707584-----

100230610

-10001380

740790990

17506/4''

3100

195099112

-----

100320670

-10201370

940790990

21506/4''

3100

2350149164

-----

100320800

-12901770

21801200140021806/4''

3100

2435245265

-----

100335800

-12701735

475650850

16706/4''

3100

1870100109

---

1,910,5100230610630

10001380

940790990

21506/4''

3100

2350185201

---

3,217,5100320800970

12901770

740790990

17506/4''

3100

1950135150

---

2,614

100320670870

10201370

475650850

16706/4''

3100

1870120129125

63/4"1,9

10,5100230610630

10001380

740790990

17506/4''

3100

1950175190170

63/4"2,614

100320670870

10201370

940790990

21506/4''

3100

2350215230170

63/4"3,2

17,5100320800970

12901770

14501000120021006/4''

3100

2300185204

-----

100320785

-12551720

3001

2960125014502695

2"3

1002915321

-----

100370

1000-

16302260

4001

3820140016002790

2"3

1003015380

-----

100420

1050-

16802310

501

CAS-B

801 1001

940790990

21506/4''

3100

2350176191170

63/4"

--

100320800

-12901770

740790990

17506/4''

3100

1950137150170

63/4"

--

100320670

-10201370

475650850

16706/4''

3100

1870105114125

63/4"

--

100230610

-10001380

EN

Page 13: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

2713Technical manual CAS, CAS-B, CAS-S i CAS-BS

Presentation, use, status at delivery

1.0. PRESENTATION

Water accumulation tanks CAS, CAS-B, CAS,S and CAS-BS are manufactured with the most modern welding technology, made from high quality steel. They are made in seven different volumes (475, 740, 940, 1450, 2160, 2960 and 3820 litres) and four different versions: water accumulation tank (CAS), with inbuilt stainless steel domestic hot water (DHW) tank (CAS-B), with inbuilt tube heat exchanger for solar collector connection (CAS-S) and with inbuilt stainless steel DHW tank and tube heat exchanger (CAS-BS). We highly recommend You to follow our technical manual with attention which brighten the construction, operation, instalation and maintenance of the water accumulation tank in order to assure a long life and proper operation condition of the product.

2.0. USE

Accumulation tanks CAS, CAS-B, CAS-S and CAS-BS are intended for accumulation of energy (for example in the central heating systems with solid fuel boilers for accumulation of thermal energy) and provide more economical and efficient operation of the system in which they are installed. Lot of versions of the water accumulation enables simultaneously use of more renewable energy sources what makes them ecologically and energetic very acceptable.

3.0. STATUS AT DELIVERY

For easier transport and positioning into boiler room, accumulation tanks CAS, CAS-B, CAS-S i CAS-BS are not supplied with built-in thermal insulation but separately as follows:- accumulation tank body- thermal insulation packed in a protective PVC foil- thermometer (4 pcs.), rosette (4 pcs. red, 3 pcs. blue and 4 pcs. black) packed in PVC bag

EN

Page 14: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Connection of the accumulation tank to central heating system should be done by recommendation and schematic drawing from boiler (heat source) manufacturer, according to this technical manual and good technical practice.

14

Max. radni pretlak sprem. (bar):

Volumen spremnika (lit.):

Tvornički broj:

Godina proizvodnje:

Tip sprem.:

Proizvođač:

AKUMULACIJSKI SPREMNIK

Volumen spremnika PTV (lit.):

Max. radni pretl. sp. PTV (bar):

Masa spremnika (kg):

Max. radni pretlak sprem. (bar):

Volumen spremnika (lit.):

Tvornički broj:

Godina proizvodnje:

Tip sprem.: CAS

2010.

d.o.o.40306 MACINEC, GLAVNA 12 - HRVATSKA

Proizvođač: Centrometal d.o.o.

AKUMULACIJSKI SPREMNIK

Volumen spremnika PTV (lit.):

Max. radni pretl. sp. PTV (bar):

Masa spremnika (kg):

cc

a.

50

cm

Technical manual CAS, CAS-B, CAS-S i CAS-BS

Installation, plate, installation to heating system

4.0. INSTALATION

5.0. PLATE WITH BASIC INFORMATION ABOUT THE PRODUCT

Picture 2. Position of the plate on the accumulation tank

Plate of accumulation tank is attached to its foundation and covered with insulation. In order to reach the plate the zipper must pulled up (open) approx. 50 cm and separate thermal insulation (see Picture 2).

2010.

d.o.o.40306 MACINEC, GLAVNA 12 - CROATIA

Centrometal d.o.o.

WATER ACCUMULATORTANK

Weight of the tank (kg):

Volume of the DHW tank (lit.):

Max. operating pressure (bar):

Volume of the tank (lit.):

Product No.:

Year of production:

Type:

Manufacturer:

Max. operating pressure of the DHW tank (bar):

6.0. INSTALLATION OF THE ACCUMULATION TANK TO CENTRAL

HEATING SYSTEM

Accumulation tanks CAS, CAS-B, CAS-S and CAS-BS are delivered on a wooden pallet. Before placing the accumulation tank in the boiler room it needs to be removed from the wooden pallet. Installation and assembly of accumulation tank and installation of additional equipment on the tank must be performed by a qualified person. Accumulation tank need to be placed on a horizontal solid foundation for the anticipated load that causes the full weight of the accumulation tank. Boiler room must be protected from freezing. Accumulation tank has to be positioned so that it can be properly connected and simultaneously, enabling tending of accumulation tank control during operation. For mounting of thermal insulation on the accumulation tank see ''Technical instructions for installation of thermal insulation and jacket for accumulation tank CAS, S-,-B,-BS'' which are delivered with thermal insulation of the tank.

EN

Page 15: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

1 - Accumulation tank CAS-B / CAS-BS2 - Expansion vessel for sanitary water3 - Safety valve with opening pressure 6 bar4 - Non-return valve5 - Pressure reducing valve6 - Stop valve7 - Hot sanitary water8 - Circulation9 - Cold sanitary water10 - Thermal 3-way mixing valve for sanitary water11 - Sensor tube12 - Connection 6/4'' (female thread)

*

**

90°

9

7

10**

2

4 *5 6

1

8

11

1211

7 9

8

123

27Tehničko uputstvo CentroMini 15Technical manual CAS, CAS-B, CAS-S i CAS-BS

Connection to water supply installation

7.0. CONNECTION OF THE ACCUMULATION TANK CAS-B AND CAS-BS

TO WATER SUPPLY INSTALLATION

Connection of stainless steel domestic hot water (DHW) tank positioned in the accumulation tank CAS-B / CAS-BS to water supply installation has to be done by an expert professional and all installation works have to be performed in accordance with available technical standards (Scheme 1.). Cold sanitary water supply line has to be connected to connection (9) (Scheme 1) (connection 3/4'') and the connection (7) (Schema 1) (connection 3/4'') is intended for disposal of hot sanitary water. Connection for circulation line (8) (connection 3/4'') is located on the right side of the cold water connection. The following has to be installed at the entry of supply line of cold sanitary water in DHW tank:

- expansion vessel for sanitary water;

- safety valve with opening pressure of 6 bar;- reducing valve which reduces cold sanitary water pressure to 4 bar (if its pressure is higher);- non-return valve.

Inlet coldsanitary water

Scheme 1. Example of installation accumulation tank CAS-BS to water supply system

* It should be built in if inlet water pressure is over 4 bars.

** recommendation

EN

Page 16: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

16 Technical manual CAS, CAS-B, CAS-S i CAS-BS

8.0. START UP

It is necessary to perform (check, if you have already performed) all actions in accordance with points 1.0. to 7.0. these instructions.Max. working pressure in the accumulation tank connected to the installation of central heating must be limited with built in safety valve with max. openning pressure 3 bar.

9.0. USE, CLEANING AND MAINTENANCE

The water accumulation tank CAS, CAS-B, CAS-S and CAS-BS have to be cleaned as needed, by discharge the accumulation tank.Before filling the tank CAS-B and CAS-BS with boiler water (heating system side), you must fill sanitary water heater tank on pressure min. 1,5 bar. Min. pressure of 1,5 bar inside the sanitary water heater tank should be kept during the usual work.

8.1. START UP - CAS / -S 501, CAS / -S 801, CAS / -S 1001, CAS / -S 1501,

CAS / -S 2001, CAS - 3001, CAS - 4001

8.2. START UP - CAS / -S 501, CAS / -S 801, CAS / -S 1001, CAS / -S 1501,

CAS / -S 2001

It is necessary to perform (check, if you have already performed) all actions in accordance with points 1.0. to 7.0. these instructions.Max. working pressure in the accumulation tank connected to the installation of central heating must be limited with built in safety valve with max. openning pressure 3 bar.Max. working pressure in the stainless steel DHW water tank connected to water supply system must be limited with built in safety valve with max. openning pressure 6 bar.Before filling the tank CAS-B and CAS-BS with boiler water (heating system side), you must fill sanitary water heater tank DHW on pressure min. 1,5 bar.

Start up, use, cleaning and maintenanceEN

Page 17: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

10.0. CHARACTERISTICS OF ACCUMULATION TANKS CAS, CAS-B, CAS-S i CAS-BS

They are manufactured from certificated metal sheet in compliance with the ISO 9001/2000 norm.They are very good thermal insulated (100 mm), the outer cover is made of artificial leather.It is possible to connect the tanks mutually in order to increase total accumulation of the system.They are produced in six different volumes and four version:- CAS 501 (475 lit.), CAS 801 (740 lit.), CAS 1001 (940 lit.), CAS 1501 (1450 lit.) and CAS 2001 (2160 lit.), CAS 3001 (2960 lit.) i CAS 4001 (3820 lit.) - water accumulation tank- CAS-S 501 (475 lit.), CAS-S 801 (740 lit.), CAS-S 1001 (940 lit.) - wat. acc. tank with inbuilt solar tube heat exchanger- CAS-B 501 (475 lit.), CAS-B 801 (740 lit.), CAS-B 1001 (940 lit.) - wat. acc. tank with inbuilt stainless steel DHW wat. tank- CAS-BS 501 (475 lit.), CAS-BS 801 (740 lit.), CAS-BS 1001 (940 lit.) - wat. acc. tank with inbuilt DHW wat. tank and heat exch.

Characteristic of accumulation tanks

27Tehničko uputstvo CentroMini 17Technical manual CAS, CAS-B, CAS-S i CAS-BS

EN

Page 18: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

18 Tehnična navodila CAS, CAS-B, CAS-S i CAS-BS

Dimenzije in osnovni deli akumulacijskega rezervoarja

CAS CAS-S

Termometer

Termometer

Toplotnaizolacija

Prostor za temp.tipalo

Prostor za temp.tipalo

F

DC

B

A

Priključek (notranji navoj) *

Termometer

Termometer

Podnožje rezervoarja

Priključek (notranji navoj) *

Priključek (notranji navoj) *

Prostor za temp.tipalo

Mjesto za temp. osjetnik

Priključek (notranji navoj)*

E

Telo rezervoarja

Cevni izmenjevalnik(notranji navoj 5/4")

CAS CAS-S

90

°

90

°

G

H

Priključek (notranji navoj) *

Priključek (notranji navoj) *

Prostor za temp.tipalo

Cevni izmenjevalnik(notranji navoj 5/4")

Priključek (notranji navoj) *

Priključek 1/2" za termometer

Cevni izmenjevalnik(notranji navoj 5/4")

Cevni izmenjevalnik(notranji navoj 5/4")

Priključek (notranji navoj) *

* - Priključek 6/4" (CAS 501 - 2001), 2" (CAS 3001 - 4001) (notranji navoj)

SLO

Page 19: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

19

Dimenzije in osnovni deli akumulacijskega rezervoarja

CAS-BS

90

°

90

°

Priključek 1/2" za termometer

Otvor za osjetnik

Cirkulacija (notranji navoj 3/4")

Topla sanitarna voda(notranji navoj 3/4")

Priključek 6/4’’(notranji navoj)

Hladna sanitarna voda(notranji navoj 3/4")

Cevni izmenjevalnik(notranji navoj 5/4")

Prostor za temp.tipalo

Hladna sanitarna voda(notranji navoj 3/4")

Topla sanitarna voda(notranji navoj 3/4")

Priključek 6/4’’(notranji navoj)

Priključek 6/4”(notranji navoj)

Cirkulacija(unutarnji navoj 3/4")

CAS-B

CAS-BSCAS-B

Termometar

Termometar

Termometar

Prostor za temperaturnotipalo

Prostor za temp.tipalo

Cijevniizmjenivač(unutarnji

navoj 5/4'')

Inox bojler PTV

Priključek 6/4” (notranji navoj)

Priključek 6/4’’(notranji navoj)

Toplinskaizolacija

Termometar

Priključek 6/4’’(not.nav.)

Priključek 6/4’’(notranji)

Prostor za temp.tipalo

Priključak 6/4’’(unut.nav.)

Prostor za temperaturnotipalo

Podnožje rezervoarja

Cevni izmenjevalnik(notranji navoj 5/4")

Cevni izmenjevalnik(notranji navoj 5/4")

Poklopec odprtineza reviziju PTV

Poklopec odprtine za reviziju PTV

Telo rezervoarja

Odprtina za tipalo

Tehnična navodila CAS, CAS-B, CAS-S i CAS-BS

SLO

Page 20: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

20

Tehnički podatki

Tip1001 2001501 801

0,8 1,0 2,0 3,0 4,0

2

3

4

5

6

8

10

20

30

40

Slika 1. Otpor protoka CAS

Količina pretoka v m /h3

Up

or

pre

toka v

mb

ar

CAS

1001501 801

CAS-S

1001501 801

CAS-BS

1501

Prostornina

Premer telesa rezervoarja G

Zunanji premer H

Skupna višina F

Priključki

Max. delovni tlak

Max. delovna temp.

Min. višina prostora

Masa prazneg telesa rezerv.

Masa prazneg rezervoarja

Prostornina rezervoarja PTV

Max. delovni tlak PTV

Priključki PTV

Ogrevalna površina spirale

Prostornina ogrevalne spirale

Toplotna izolacija

Višina A

Višina B

Višina C

Višina D

Višina E

(lit.)(mm)(mm)(mm)

(R)(bar)(°C)

(mm)(kg)(kg)(lit.)

(bar)(R)

2(m )(lit.)

(mm)(mm)(mm)(mm)(mm)(mm)

3001 4001

Tehnična navodila CAS, CAS-B, CAS-S i CAS-BS

501

CAS-B

801 1001

475650850

16706/4''

3100

18707584-----

100230610

-10001380

740790990

17506/4''

3100

195099112

-----

100320670

-10201370

940790990

21506/4''

3100

2350149164

-----

100320800

-12901770

21801200140021806/4''

3100

2435245265

-----

100335800

-12701735

475650850

16706/4''

3100

1870100109

---

1,910,5100230610630

10001380

940790990

21506/4''

3100

2350185201

---

3,217,5100320800970

12901770

740790990

17506/4''

3100

1950135150

---

2,614

100320670870

10201370

475650850

16706/4''

3100

1870120129125

63/4"1,9

10,5100230610630

10001380

740790990

17506/4''

3100

1950175190170

63/4"2,614

100320670870

10201370

940790990

21506/4''

3100

2350215230170

63/4"3,2

17,5100320800970

12901770

14501000120021006/4''

3100

2300185204

-----

100320785

-12551720

2960125014502695

2"3

1002915321

-----

100370

1000-

16302260

3820140016002790

2"3

1003015380

-----

100420

1050-

16802310

940790990

21506/4''

3100

2350176191170

63/4"

--

100320800

-12901770

740790990

17506/4''

3100

1950137150170

63/4"

--

100320670

-10201370

475650850

16706/4''

3100

1870105114125

63/4"

--

100230610

-10001380

SLO

Page 21: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

2721

1.0. PREDSTAVITEV

Predstavljanje, namen, stanje pri dobavi

Akumulacijski rezervoarji CAS, CAS-B, CAS-S i CAS-BS podjetja Centrometal d.o.o. so izdelani s pomočjo najsodobnejše tehnologije varjenja iz kvalitetnega jekla. Izdelujejo se v 7 prostorninah (475, 740, 940, 1450, 2160, 2960 in 3820 litrov) in v 4 izvedbah: kot akumulacijski rezervoar (CAS), z vgrajenim inox bojlerjem za pripravo tople sanitarne vode (CAS-B), z vgrajenim cevnim izmenjevalnikom za priključitev sončnih kolektorjev (CAS-S) in z vgrajenim inox bojlerjem ter cevnim izmenjevalnikom (CAS-BS). Če boste upoštevali tehnična navodila, ki pojasnjujejo konstrukcijo, način dela, priključitev in vzdrževanje akumulacijskega rezervoarja, vam je zagotovljeno nemoteno in ekonomično delovanje izdelka.

Akumulacijski rezervoarji CAS, CAS-B, CAS-S i CAS-BS so namenjeni akumuliranju energije (npr. v centralnih ogrevalnih sistemih poleg kotlov na trdo gorivo z namenom akumuliranja toplotne energije) ter zagotavljajo bolj ekonomično in učinkovito delovanje samega sistema, v katerega so vgrajeni. Več izvedb teh rezervoarjev omogočajo istočasno uporabo več obnovljivih virov energije, zaradi česar so ekološko in energijsko sprejemljivejši.

2.0. NAMEN

3.0. STANJE OB DOBAVI

Akumulacijski rezervoarji CAS, CAS-B, CAS-S i CAS-BS se zaradi lažjega transporta in lažjega postavljanja ne dobavljajo z montirano toplotno izolacijo, temveč posebej:- telo akumulacijskega rezervoarja na leseni paleti- toplotna izolacija zapakirane v zaščitno PVC folijo- termometer (4 kosi), tulec za termometer (4 kosi), rozete (črne) zapakirane v PVC vrečko

Tehnična navodila CAS, CAS-B, CAS-S i CAS-BS

SLO

Page 22: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

22

4.0. POSTAVITEV

Akumulacijski rezervoarji CAS, CAS-B, CAS-S in CAS-BS se dobavljajo na leseni paleti. Pred postavljanjem akumulacijskega rezervoarja na predvideno mesto v kotlovnici ga morate sneti z lesene palete. Postavljanje in sestavljanje akumulacijskega rezervoarja in vgradnja dodatne opreme na rezervoar mora biti izpeljana s strani strokovne osebe. Akumulacijski rezervoar morate postaviti na horizontalno trdno površino, ki je predvidena za prenašanje obremenitev, ki jih povzroča masa polnega rezervoarja. Kotlovnica mora biti zaščitena pred zamrzovanjem. Rezervoar morate postaviti tako, da je njegovo priključitev možno izvesti korektno, vendar da je hkrati ob tem omogočen nadzor med delom. Za montažo toplotne izolacije na akumulacijski rezervoar glejte ''Tehnična navodila za montažo toplotne izolacije akumulacijskega rezervoarja CAS, -S; -B; -BS'', ki so priložena rezervoarju (priložen je tudi garancijski list).

6.0. PRIKLJUČITEV AKUMULACIJSKEGA REZERVOARJA NA

CENTRALNO OGREVALNO NAPELJAVO

Priključitev rezervoarja na centralno ogrevalno napeljavo morate izvesti po priporočilih in shemi proizvajalca kotla (toplotni vir) in hkrati v skladu s temi tehničnimi navodili in strokovnimi pravili.

5.0. NAPISNA PLOŠČICA Z OSNOVNIMI PODATKI O PROIZVODU

Max. radni pretlak sprem. (bar):

Volumen spremnika (lit.):

Tvornički broj:

Godina proizvodnje:

Tip sprem.: CAS

2010.

d.o.o.40306 MACINEC, GLAVNA 12 - HRVATSKA

Proizvođač: Centrometal d.o.o.

AKUMULACIJSKI SPREMNIK

Volumen spremnika PTV (lit.):

Max. radni pretl. sp. PTV (bar):

Masa spremnika (kg):

Max. radni pretlak sprem. (bar):

Volumen spremnika (lit.):

Tvornički broj:

Godina proizvodnje:

Tip sprem.: CAS

2010.

d.o.o.40306 MACINEC, GLAVNA 12 - HRVATSKA

Proizvođač: Centrometal d.o.o.

AKUMULACIJSKI SPREMNIK

Volumen spremnika PTV (lit.):

Max. radni pretl. sp. PTV (bar):

Masa spremnika (kg):

Napisna ploščica akumulacijskegarezervoarja je pritrjena na podnožju rezervoarja in prekrita s toplotno izolacijo. Če želite dostopati do napisne ploščice, morate patentno zapiralo toplotne izolacije povleči navzgor (odpreti) za cca. 50 cm in jo razmakniti (glejte sliko 2.).

Slika 2. Položaj napisne ploščice na akumulacijskem rezervoarju

cc

a.

50

cm

Postavitev, napisna ploščica, priključitev na instalacijo ogrevanja

Tehnična navodila CAS, CAS-B, CAS-S i CAS-BS

SLO

Page 23: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Shema 1. Primer vgradnje akumulacijskega rezervoarja CAS-BS na vodovodno napeljavo

1 - Akumulacijski rezervoar CAS-B/CAS-BS2 - Ekspanzijska posoda za sanitarno vodo3 - Varnostni ventil s tlakom odpiranja 6 barov4 - Nepovratni ventil5 - Regulator tlaka6 - Zaporni ventil7 - Topla sanitarna voda8 - Cirkulacija9 - Hladna sanitarna voda10 - 3-potni termostatski mešalni ventil za sanitarno vodo11 - Odprtina za tipalo12 - Priključek 6/4" (notranji navoj)

* potrebno je vgraditi, če je tlak vhodne vode večji od 4 bare

*

**

** priporočilo

90°

9

7

10**

Vhod za hladno sanitarno vodo

2

4 *5 6

1

8

11

12 11

7 9

8

12

3

2723

Priključitev na vodovodnu napeljavu

7.0. PRIKLJUČITEV AKUMULACIJSKEGA REZERVOARJA CAS- B IN

CAS- BS NA VODOVODNO NAPELJAVO

Priključitev inox bojlerja v akumulacijskem rezervoarju CAS-B/CAS-BS na vodovodno napeljavo mora v skladu z veljavnimi tehničnimi standardi izpeljatistrokovna oseba (Shema 1.). Dovod hladne sanitarne vode je potrebno priključiti na priključek 9 (Shema 1.) (objemka 3/4''), priključek 7 (Shema 1.) (objemka 3/4'') pa se uporablja za odvod tople sanitarne vode. Priključek cirkulacijskega voda 8 (objemka 3/4'') se nahaja na desni strani priključka za hladno vodo.Na vhod hladne sanitarne vode v bojler je obvezna vgradnja: - ekspanzijske posode za sanitarno vodo; - varnostnega ventila s tlakom odpiranja 6 barov; - redukcijskega ventila, ki znižuje tlak vhodne hladne sanitarne vode na 4 bare (če je njen tlak večji); - nepovratnega ventila.

Tehnična navodila CAS, CAS-B, CAS-S i CAS-BS

SLO

Page 24: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

Potrebno je izpeljati (preveriti, če so že bila izpeljana) vsa dela v skladu s točkama od 1.0. do 7.0., ki sta navedeni v teh navodilih. Maksimalni delovni tlak v rezervoarju, priključenem na centralno ogrevalno napeljavo mora biti omejen z vgrajenim varnostnim ventilom s tlakom odpiranja maks. 3 bare.

8.0. ZAGON

8.1. ZAGON - CAS / -S 501, CAS / -S 801, CAS / -S 1001, CAS / -S 1501,

CAS / -S 2001, CAS - 3001, CAS - 4001

8.2. ZAGON - CAS-B / -BS 501, CAS-B / -BS 801, CAS-B / -BS 1001,

CAS-B / -BS 1501, CAS-B / -BS 2001

Potrebno je izpeljati (preveriti, če so že bila izpeljana) vsa dela v skladu s točkama od 1.0. do 7.0., ki sta navedeni v teh navodilih. Maksimalni delovni tlak v rezervoarju, priključenem na centralno ogrevalno napeljavo mora biti omejen z vgrajenim varnostnim ventilom s tlakom odpiranja maks. 3 bare.

Maksimalni delovni tlak v inox bojlerju za sanitarno vodo, priključenem na vodovodno napeljavo omejen z vgrajenim varnostnim ventilom s tlakom odpiranja

maks. 6 barov. Pred polnjenjem akumulacijskega rezervoarja izvedbe CAS-B i CAS-BS s kotlovno vodo (stran ogrevalnega sistema), se mora najprej napolniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bara.

24

Akumulacijski rezervoar CAS, CAS-B, CAS-S in CAS-BS je treba čistiti potrebi

tako, da izpraznite posodo. Vsakič preden napolnite akumulacijski rezervoar v izvedbah CAS-B in CAS-BS s kotlovno vodo (stran ogrevalnega sistema), morate napolniti najprej inox bojler PTV (sanitarna voda) s tlakom minimalno 1,5 barov. Minimalni tlak naj znaša 1,5 barov v inox bojlerju PTV (sanitarna voda) in ga ohranjujte med delovanjem.

9.0. UPORABA, ČIŠČENJE IN VZDRŽEVANJE

Zagon, uporaba, čiščenje in vzdrževanje

Tehnična navodila CAS, CAS-B, CAS-S i CAS-BS

SLO

Page 25: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

2725

Karakteristike akumulacijskih rezervoarjev

10.0. KARAKTERISTIKE AKUMU. REZERVOARJEV CAS, CAS-B, CAS-S in CAS-BS

Izdelani so iz atestirane jeklene pločevine v skladu s standardom ISO 9001/2000.Dobra toplotna izolacija (100 mm) obložena z oblogo iz skaja.Možno je povezovanje več rezervoarjev skupaj z namenom povečanja skupne akumulacije.Izdelujejo se v 7 prostorninah in 4 izvedbah:- CAS 501 (475 litrov), CAS 801 (740 litrov), CAS 1001 (940 litrov), CAS 1501 (1450 litrov) in CAS 2001 (2160 litrov), CAS 3001 (2960 litrov) in CAS 4001 (3820 litrov) - akumulacijski rezervoar - CAS-S 501 (475 litrov), CAS-S 801 (740 litrov), CAS-S 1001 (940 litrov) - akumul. rezervoar s cevnim izmenjevalnikom- CAS-B 501 (475 litrov), CAS-B 801 (740 litrov), CAS-B 1001 (940 litrov) - akumul. rezervoar z inox bojlerjem za san. vodo- CAS-BS 501 (475 litrov), CAS-BS 801 (740 litrov), CAS-BS 1001 (940 litrov) - akumul. rezerv. z inox bojlerjem in cev . izmenj.

Tehnična navodila CAS, CAS-B, CAS-S i CAS-BS

SLO

Page 26: CAS; -S; -B; -BS - centrometal.hr · sustava grijanja), mora se napuniti inox bojler PTV (sanitarna voda) na tlak minimalno 1,5 bar-a. 8 Tehničko uputstvo CAS, CAS-B, CAS-S i CAS-BS

HEATING TECHNIQUE

www.centrometal.hre-mail: [email protected]

Centrometal d.o.o. Glavna 12, 40306 Macinec, Croatia

central tel: +385 40 372 600, fax: +385 40 372 611service tel: +385 40 372 622, fax: +385 40 372 621

Centrometal d.o.o. shall not be responsible for possible incorrect data caused by printing errors or error made in transcription and all figures and diagrams are for explanatory purposes only and relevant adjustment have to be made at the spot. In any case, it reserves the right to modify its products as deemed to be required and useful without any prior notification.

Tvrtka Centrometal d.o.o. ne preuzima odgovornost za moguće netočnosti u ovoj brošuri, nastale tiskanim greškama ili prepisivanjem, u svakom slučaju pridržava si pravo unositi vlastitim proizvodima one izmjene koje smatra potrebnim i korisnim.

Podjetje Centrometal d.o.o. ne prevzema odgovornosti za možne napake v teh tehničnih navodilih, ki bi nastale zaradi tiskarskih napak pri prepisovanju ali prevajanju. Vse slike in sheme so približne in vsako je treba prilagoditi resničnemu stanju na terenu. V vsakem primeru si podjetje pridržuje pravico, da v svoje lastne proizvode vnese spremembe, za katere meni, da so potrebne.