Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 1 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
PARKING ACCESSORIES AND TRAFFIC CONTROL DEVICES
PARKING TICKET BOOTH DESIGN
Specifications:1. Painted GI sheet ga. 14, spray paint finish
2. 6mm thick tinted tempered glass for door and windows3. Aircon provision at the bottom part 0.50 HP; no-drip4. Single Ticket Booth = 1.10 (W) X 1.50 (L) meters5. Double Ticket Booth (Hybrid) = 1.50 (W) X 3.00 (L) meters6. Epoxy paint on 0.10 meters base - No ticket booth shall be installed directly on grade level.
7/31/2019 Carparks Standards II Final as of 11292011
2/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 2 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
BOOTH DESIGN
WITH AIRCON PROVISION
7/31/2019 Carparks Standards II Final as of 11292011
3/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 3 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
ENTRANCE SIGNS
Specifications: 60cm width by 45cm height 3M reflectorized backing sticker - BLUE 3M translucent graphical film font/graphics - WHITE Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick
Use Informative sign Location and mounting entrance driveway mounted on movable a-frame or barrier
Use Informative sign Location and mounting directly mounted on ticket booth
7/31/2019 Carparks Standards II Final as of 11292011
4/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 4 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
VERTICAL CLEARANCE SIGN
Specifications: As indicated in the Road Signs and Pavement Markings Manual, DPWH, 2007 3M reflectorized backing sticker - WHITE 3M translucent graphical film font/graphics - BLACK Plain carbon steel not less than 1.6mm thick
or Aluminum alloy not less than 2.0mm thick
Use Height Restriction Signs (See also R6-3 for Symbolic Height Restriction Signs) Location and mounting entrance driveway mounted on ceiling or beam
7/31/2019 Carparks Standards II Final as of 11292011
5/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 5 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
CAR PARK OPERATING HOURS
Specifications: 60cm height by 45cm width 3M reflectorized backing sticker - WHITE 3M translucent graphical film font/graphics - GREEN Plain carbon steel not less than 1.6mm thick
or Aluminum alloy not less than 2.0mm thick
Use Informative sign Location and mounting entrance driveway mounted on
fixed post or wall
RULES AND REMINDERS
Specifications: 92cm height by 67cm width 3M reflectorized backing sticker - WHITE 3M translucent graphical film font/graphics GREEN for font/typeface; BLACK for symbols Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick
Use Informative sign Location and mounting entrance driveway mounted on fixed post or wall. Alternative location on
elevator lobby or main pedestrian entry to building facility
7/31/2019 Carparks Standards II Final as of 11292011
6/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 6 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
DIRECTIONAL SIGNS AND LEVEL INDICATOR
Specifications: 3M reflectorized backing sticker - BLUE 3M translucent graphical film font/graphics WHITE; 6 min. font Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick
Use Directional sign
Location and mountingo Directional exit signs along driveways preferably especially at turns and intersections.
Provide supplementary signs on driveways between turns.o Level indicator Ramp landings (for multi-level parking structures)o Mounting Directly fixed on wall or ceiling-hung
25cm height by 113cm width
25cm height by 135cm width
E X I TLEVEL 8
7/31/2019 Carparks Standards II Final as of 11292011
7/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 7 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
RESERVED SLOT LABEL
Specifications: 30cm width x 7.5cm height 3M reflectorized backing sticker - White 3M translucent graphical film font Blue Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick
Use Slot label Location and mountingo Location Reserved parking slotso Mounting Directly fixed on wall or wheel stop
AMENITY SIGNS
Specifications: 22cm height by 90cm width 3M reflectorized backing sticker WHITE 3M translucent graphical film fontGREEN; 3 min. font Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick
Use Amenity directional signs for pedestrians Location and mounting
o Location Walls and landings along pedestrian paths and walkways
o Mounting Directly fixed on wall or ceiling-hung
7/31/2019 Carparks Standards II Final as of 11292011
8/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 8 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
COLUMN INDICATOR
Specifications: 30cm height by 35cm width 3M reflectorized backing sticker BLUE 3M translucent graphical film font WHITE Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick
Use Directional sign to guide motorist in locating parked vehicle Location and mounting directly fixed on column
STANDARD TRAFFIC SIGNS
Specifications: As indicated in the Road Signs and Pavement Markings Manual, DPWH, 2007
7/31/2019 Carparks Standards II Final as of 11292011
9/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 9 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
BOOM GATE
Specifications: Electromechanical barriers, 24Vdc, with adjustable speed
and anti-crushing safety feature; fixed arm or articulated Use Entrance and exit traffic control device
TRAFFIC CONE
Specifications: Traffic cones shall be fluorescent red or orange plastic that is resilient to impact and will not damage
vehicles when hit at low speed. For night time operation, the cones must be fitted with reflective tapewith a minimum bandwidth of 150mm.
Use Delineation of tapers, merges, lane separation or similar temporary measures.
http://www.google.com/imgres?q=TRAFFIC+CONE+DIMENSION&um=1&hl=en&sa=N&biw=1280&bih=571&tbm=isch&tbnid=dRrJ1dTCDahkpM:&imgrefurl=http://www.trafficconesandsafetycones.com/trafficcones/Hi_Spec_Traffic_Cone.html&docid=0sNCNf0TbB8A-M&w=220&h=301&ei=O0kyTu71M4jTiAKcpfjDCA7/31/2019 Carparks Standards II Final as of 11292011
10/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 10 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
SPEED BUMP/HUMPS
Specifications:
Speed Ramp: 1 x Black, 1 x Yellow (0.50m) section with end caps, heavy duty recycled PVCsegments.
Height level at 5.0cm Fixing method - bolt down or alternative fixing methods.
Use
Traffic calming device to avoid over speeding
DELINEATOR POST/MOVABLE BOLLARD
Specifications: Plastic movable bollard shall be fluorescent red or orangeplastic with heavy rubber base for extra stability.Equipped with 6 reflective tape for night visibility.
Use Demarcating traffic flow. Can be interlinked with nylon/plastic chains
FIXED METAL BOLLARD
Specifications:
Height: 950mm or 1200mm above ground Diameter 114mm Finish: Traffic yellow paint with 2 x red reflective strips
(highways-compatible reflectivity) Base Plate: 150mm Square with 4 x 12mm bolt holes
Use Protect facility/equipment/ticket booth for
parking operations
7/31/2019 Carparks Standards II Final as of 11292011
11/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 11 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
PARKING MANAGEMENT SYSTEM
PMS components: Unmanned Entrance Terminal Manned POS Exit Terminal Back-End Server Terminal Slot Display PMS Software/Application with reports
Network Structured Cabling
Unmanned Entrance Terminal
UNMANNED ENTRANCE
TERMINALSPECIFICATION / DETAILS
Vehicle Loop Detector / Sensor With loop coil system
Proximity Card Reader / Writer
Long range; 60cm - 90 cm or more; 125 KHz
frequency range; with Stand; card is readable even if
the parker taps inside the vehicle with close window
and door.
Unmanned Terminal Kiosk with
casing Overall, transaction time is 4 sec. max.
Industrial Terminal PC
Based Controller
Hardware: Motherboard Processor Memory Hard Disk Power Supply Video Card LAN Card Audio Card USB
Software: Operating System - Windows 7 (Professional) Antivirus License - Sophos / Trend Micro /
Kaspersky / Eset Nod32
Dual Card Dispenser
Read and write contact less IC Card (MIFARE);
Capable of giving alarm or notification at the
monitoring room (eg. if there are only 30
remaining parking cards)
7/31/2019 Carparks Standards II Final as of 11292011
12/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 12 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
Can hold minimum of 300 cards per dispenser
Prox Card Reader/Writer
Intercom System Clear and Audible Sound; No extra noise and delay.
Speaker System Clear and Audible Sound; No extra noise and delay.
Digital Greeting System Clear and Audible Sound; No extra noise and delay.
KVM (Keyboard, Video,
Mouse)
Monitor - 15" industrial type with tempered
glass; LCD or LED Keyboard USB Type Mouse - USB Type
Automatic Parking Barrier
(Boom) Gate
- With Rubber; Type of barrier arm will depend on the
structural design (eg. Articulated)
CCTV System- 2 sets - 1 pointing to the front of vehicle seing the
driver and 1 pointing to plate number;
- clear capture/recording day and night.
Vehicle Loop Detector / SensorWith loop coil system; Use of Sensor (infrared) or loop
detector will depend on the environment of car park.
Lane barrier Design and other details will be discuss during the
project planning and designUninterruptible Power System
(UPS)At least 2 KVA; On-line UPS; Liebert ; outdoor type
Bollard2 pairs: 1 pair protecting the card reader and 1 pair
protecting the Unmanned Terminal Kiosk
SignageDesign and content will be discussed during the
project planning and design.
Traffic System (Stop and Go)Design and location will be discussed during the
project planning and design.
Power System & Grounding
System
Design and location will be discussed during the
project planning and design.
Parking Cards RetailParker
Smartcard ICs - MIFARE 13.56MHz frequency range
VIP Parker 125KHz frequency range
7/31/2019 Carparks Standards II Final as of 11292011
13/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 13 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
Manned POS Exit Terminal
MANNED POS EXIT TERMINAL SPECIFICATION / DETAILS
Industrial POS Controller
POS Parking Exit Terminal (Parking management and cashier station)
CPU Pentium Dual Core T4400
2.16G
PE735 All-in-one Touch screen PC - LCD 17"
screen WXGA Memory (RAM) 1G DDR2 - 160G SATA Hard Disk
Drive ODD DVDRW - Chipset Intel 945GC Graphic Card GMA950(integrated) Acc: KB and Mouse MS Windows XP Pro; Antivirus, Ready On
Card readerRead/write contactless IC card (MIFARE 13.56 MHz
frequency range)
Electronic Cash Drawer 24V
Alphanumeric Customer Display
POS PrinterThermal Printer/Paper Speed and other specifications to be defined by
the respective PM/Proponent
Uninterruptible Power System
(UPS)
At least 2 KVA; outdoor type Varies if the whole equipment's power
requirements is higher than the set
specification.
Automatic Parking Barrier
Design and location will be discussed during the
project planning and design.
Vehicle loop detector / sensor
with loop cable system
Proximity reader (60cm - 90cm or
more) - 125 KHz frequency rangeCCTV Camera System
Intercom System
Traffic System (Stop and Go)
7/31/2019 Carparks Standards II Final as of 11292011
14/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 14 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
Back-End Server Terminal
BACK-END SERVER
TERMINALSPECIFICATION / DETAILS
Computer Set (Server -
Industrial Type) CPU (Central
Processing Unit)
IBM System x3500 M3
* 5U tower with optional rack-mount capability
* Up to two six-core Intel Xeon X5690 3.46 GHz
processors or four-core Intel Xeon X5687 3.60 GHz
processors (configure to order only) with 12 MB of cache
per processor socket
* 1333 MHz, DDR-3 registered DIMM memory
* Up to seven high-performance PCIe I/0 slots standard,
additional two PCI-X slots available via configure to order
only (requires the removal of one standard PCIe I/O slot).
* Supports up to eight or 16 small form factor (2.5") hot-
swap Serial Attached SCSI (SAS) or Serial ATA (SATA) hard
disk drives (HDDs) standard; additional options available to
support maximum 24 SFF 2.5" SAS/SATA HDDs; up to four
3.5" simple-swap SATA HDDs or up to eight 3.5" hot-swapSAS or SATA HDDs (available via configure to order only).
* 6 Gbps RAID and 3 Gbps adapters standard
KVM (Keyboard, Video (Monitor, Mouse) Keyboard USB Type Monitor17 LED Mouse USB Type
Operating System MS Windows Server 2008 - Standard w/ 5 CAL MS Windows Server CAL 2008 CAL
Database System Microsoft SQL Server 2008 (Standard)
UPS (Uninterruptible
Power Supply) Online; 5KVA; Rack MountPower System with
Grounding System
Server Room with Cooling
System
DVR Controller
Storage Server / File Server
7/31/2019 Carparks Standards II Final as of 11292011
15/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 15 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
Back-Office Terminal
BACK-OFFICE TERMINAL SPECIFICATION / DETAILS
Computer Set (Desktop -
Industrial Type)ALI/APMC Desktop Standard.
CPU (Central Processing Unit)
Motherboard
Processor Memory (RAM) Hard Disk Power Supply Video Card Audio Card LAN Card Modem Card
KVM (Keyboard, Video (Monitor), Mouse) Keyboard Monitor
MouseDVD Reader & Writer
Speaker with Amplifier and Microphone System
Software MS Windows 7 Standard MS Office 2007 Standard Antivirus System
Intercom System
Card Reader / Writer EZ Wave MiFare Reader / Writer
Promag VIP Card Writer
UPS (Uninterruptible Power
Supply)
APC Smart UPS; at least 420VA; Minimum of 5
outletsPrinter HP Laserjet Printer
7/31/2019 Carparks Standards II Final as of 11292011
16/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 16 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
Slot Display
SLOT DISPLAY REMARKS
Main Entrance Slot Display
Main Entrance Slot Display w/ Sub Level
Summary Metal Casing w/ Cooling System 5100 Data Terminal Slot Controller w/ I/O Circuit
Vehicle Loop Detector w/ Loop Cable or Sensor
Per level Slot Display (Optional
for Building Car parks)
Per Level Slot Display Metal Casing w/ Cooling System 5100 Data Terminal Slot Controller w/ I/O Circuit Vehicle Loop Detector w/ Loop Cable or Sensor
PMS Software/Application
PMS SOFTWARE/APPLICATION REMARKS
Unmanned Entrance w/ Ads display management With Reporting and analytics to bedefined by the respective
PM/Proponent
Back-End (Server and Back-Office)
POS Exit System
Network Structured Cabling
NETWORK STRUCTURED
CABLINGSPECIFICATION / DETAILS
Data cabling (Cat6)with at least 25 years product warranty (ex. Siemon /
Systemax / Belden)
Rack and Accessories
- Closed Data Cabinet with cooling system
- 14RU, black color, tainted glass (front door)
- with PDU minimum of 10 outlets
- 110 terminal block for tel. lines
- Cable Manager- Patch Panel
Roughing-ins -
Managed Cisco Catalyst
2960 Switch
24 port with at least 2 fiber module; 10/100; 1RU;
Software/Drivers;
7/31/2019 Carparks Standards II Final as of 11292011
17/17
Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT
FMD-WI-11-02.33.3B
Subject: WORK INSTRUCTIONSCar Parks Technical
Standards II (Parking Accessories and Traffic Control)
Revision Code: 0 Page 17 of 17
Effectivity: 1 December 2011Prepared By:
PVBasaya/RCCarreon
Reviewed By:
SGVinoya
Approved By:
RTMenpin/RMIrlanda
QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM
WORK INSTRUCTION
Ayala
Property
ManagementCorporation
References:
Parking Management (The Next Level), Vol. 2, Parking 101 Series, International Parking Institute Road Works Safety Manual, Department of Public Works and Highways, Jan 2004
Road Signs and Pavement Markings Manual, Department of Public Works and Highways, Jan 2004
Manual on Uniform Traffic Control Devices (MUTCD)
National Building Code