Carparks Standards II Final as of 11292011

Embed Size (px)

Citation preview

  • 7/31/2019 Carparks Standards II Final as of 11292011

    1/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 1 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    PARKING ACCESSORIES AND TRAFFIC CONTROL DEVICES

    PARKING TICKET BOOTH DESIGN

    Specifications:1. Painted GI sheet ga. 14, spray paint finish

    2. 6mm thick tinted tempered glass for door and windows3. Aircon provision at the bottom part 0.50 HP; no-drip4. Single Ticket Booth = 1.10 (W) X 1.50 (L) meters5. Double Ticket Booth (Hybrid) = 1.50 (W) X 3.00 (L) meters6. Epoxy paint on 0.10 meters base - No ticket booth shall be installed directly on grade level.

  • 7/31/2019 Carparks Standards II Final as of 11292011

    2/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 2 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    BOOTH DESIGN

    WITH AIRCON PROVISION

  • 7/31/2019 Carparks Standards II Final as of 11292011

    3/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 3 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    ENTRANCE SIGNS

    Specifications: 60cm width by 45cm height 3M reflectorized backing sticker - BLUE 3M translucent graphical film font/graphics - WHITE Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick

    Use Informative sign Location and mounting entrance driveway mounted on movable a-frame or barrier

    Use Informative sign Location and mounting directly mounted on ticket booth

  • 7/31/2019 Carparks Standards II Final as of 11292011

    4/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 4 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    VERTICAL CLEARANCE SIGN

    Specifications: As indicated in the Road Signs and Pavement Markings Manual, DPWH, 2007 3M reflectorized backing sticker - WHITE 3M translucent graphical film font/graphics - BLACK Plain carbon steel not less than 1.6mm thick

    or Aluminum alloy not less than 2.0mm thick

    Use Height Restriction Signs (See also R6-3 for Symbolic Height Restriction Signs) Location and mounting entrance driveway mounted on ceiling or beam

  • 7/31/2019 Carparks Standards II Final as of 11292011

    5/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 5 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    CAR PARK OPERATING HOURS

    Specifications: 60cm height by 45cm width 3M reflectorized backing sticker - WHITE 3M translucent graphical film font/graphics - GREEN Plain carbon steel not less than 1.6mm thick

    or Aluminum alloy not less than 2.0mm thick

    Use Informative sign Location and mounting entrance driveway mounted on

    fixed post or wall

    RULES AND REMINDERS

    Specifications: 92cm height by 67cm width 3M reflectorized backing sticker - WHITE 3M translucent graphical film font/graphics GREEN for font/typeface; BLACK for symbols Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick

    Use Informative sign Location and mounting entrance driveway mounted on fixed post or wall. Alternative location on

    elevator lobby or main pedestrian entry to building facility

  • 7/31/2019 Carparks Standards II Final as of 11292011

    6/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 6 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    DIRECTIONAL SIGNS AND LEVEL INDICATOR

    Specifications: 3M reflectorized backing sticker - BLUE 3M translucent graphical film font/graphics WHITE; 6 min. font Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick

    Use Directional sign

    Location and mountingo Directional exit signs along driveways preferably especially at turns and intersections.

    Provide supplementary signs on driveways between turns.o Level indicator Ramp landings (for multi-level parking structures)o Mounting Directly fixed on wall or ceiling-hung

    25cm height by 113cm width

    25cm height by 135cm width

    E X I TLEVEL 8

  • 7/31/2019 Carparks Standards II Final as of 11292011

    7/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 7 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    RESERVED SLOT LABEL

    Specifications: 30cm width x 7.5cm height 3M reflectorized backing sticker - White 3M translucent graphical film font Blue Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick

    Use Slot label Location and mountingo Location Reserved parking slotso Mounting Directly fixed on wall or wheel stop

    AMENITY SIGNS

    Specifications: 22cm height by 90cm width 3M reflectorized backing sticker WHITE 3M translucent graphical film fontGREEN; 3 min. font Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick

    Use Amenity directional signs for pedestrians Location and mounting

    o Location Walls and landings along pedestrian paths and walkways

    o Mounting Directly fixed on wall or ceiling-hung

  • 7/31/2019 Carparks Standards II Final as of 11292011

    8/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 8 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    COLUMN INDICATOR

    Specifications: 30cm height by 35cm width 3M reflectorized backing sticker BLUE 3M translucent graphical film font WHITE Plain carbon steel not less than 1.6mm thick or Aluminum alloy not less than 2.0mm thick

    Use Directional sign to guide motorist in locating parked vehicle Location and mounting directly fixed on column

    STANDARD TRAFFIC SIGNS

    Specifications: As indicated in the Road Signs and Pavement Markings Manual, DPWH, 2007

  • 7/31/2019 Carparks Standards II Final as of 11292011

    9/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 9 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    BOOM GATE

    Specifications: Electromechanical barriers, 24Vdc, with adjustable speed

    and anti-crushing safety feature; fixed arm or articulated Use Entrance and exit traffic control device

    TRAFFIC CONE

    Specifications: Traffic cones shall be fluorescent red or orange plastic that is resilient to impact and will not damage

    vehicles when hit at low speed. For night time operation, the cones must be fitted with reflective tapewith a minimum bandwidth of 150mm.

    Use Delineation of tapers, merges, lane separation or similar temporary measures.

    http://www.google.com/imgres?q=TRAFFIC+CONE+DIMENSION&um=1&hl=en&sa=N&biw=1280&bih=571&tbm=isch&tbnid=dRrJ1dTCDahkpM:&imgrefurl=http://www.trafficconesandsafetycones.com/trafficcones/Hi_Spec_Traffic_Cone.html&docid=0sNCNf0TbB8A-M&w=220&h=301&ei=O0kyTu71M4jTiAKcpfjDCA
  • 7/31/2019 Carparks Standards II Final as of 11292011

    10/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 10 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    SPEED BUMP/HUMPS

    Specifications:

    Speed Ramp: 1 x Black, 1 x Yellow (0.50m) section with end caps, heavy duty recycled PVCsegments.

    Height level at 5.0cm Fixing method - bolt down or alternative fixing methods.

    Use

    Traffic calming device to avoid over speeding

    DELINEATOR POST/MOVABLE BOLLARD

    Specifications: Plastic movable bollard shall be fluorescent red or orangeplastic with heavy rubber base for extra stability.Equipped with 6 reflective tape for night visibility.

    Use Demarcating traffic flow. Can be interlinked with nylon/plastic chains

    FIXED METAL BOLLARD

    Specifications:

    Height: 950mm or 1200mm above ground Diameter 114mm Finish: Traffic yellow paint with 2 x red reflective strips

    (highways-compatible reflectivity) Base Plate: 150mm Square with 4 x 12mm bolt holes

    Use Protect facility/equipment/ticket booth for

    parking operations

  • 7/31/2019 Carparks Standards II Final as of 11292011

    11/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 11 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    PARKING MANAGEMENT SYSTEM

    PMS components: Unmanned Entrance Terminal Manned POS Exit Terminal Back-End Server Terminal Slot Display PMS Software/Application with reports

    Network Structured Cabling

    Unmanned Entrance Terminal

    UNMANNED ENTRANCE

    TERMINALSPECIFICATION / DETAILS

    Vehicle Loop Detector / Sensor With loop coil system

    Proximity Card Reader / Writer

    Long range; 60cm - 90 cm or more; 125 KHz

    frequency range; with Stand; card is readable even if

    the parker taps inside the vehicle with close window

    and door.

    Unmanned Terminal Kiosk with

    casing Overall, transaction time is 4 sec. max.

    Industrial Terminal PC

    Based Controller

    Hardware: Motherboard Processor Memory Hard Disk Power Supply Video Card LAN Card Audio Card USB

    Software: Operating System - Windows 7 (Professional) Antivirus License - Sophos / Trend Micro /

    Kaspersky / Eset Nod32

    Dual Card Dispenser

    Read and write contact less IC Card (MIFARE);

    Capable of giving alarm or notification at the

    monitoring room (eg. if there are only 30

    remaining parking cards)

  • 7/31/2019 Carparks Standards II Final as of 11292011

    12/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 12 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    Can hold minimum of 300 cards per dispenser

    Prox Card Reader/Writer

    Intercom System Clear and Audible Sound; No extra noise and delay.

    Speaker System Clear and Audible Sound; No extra noise and delay.

    Digital Greeting System Clear and Audible Sound; No extra noise and delay.

    KVM (Keyboard, Video,

    Mouse)

    Monitor - 15" industrial type with tempered

    glass; LCD or LED Keyboard USB Type Mouse - USB Type

    Automatic Parking Barrier

    (Boom) Gate

    - With Rubber; Type of barrier arm will depend on the

    structural design (eg. Articulated)

    CCTV System- 2 sets - 1 pointing to the front of vehicle seing the

    driver and 1 pointing to plate number;

    - clear capture/recording day and night.

    Vehicle Loop Detector / SensorWith loop coil system; Use of Sensor (infrared) or loop

    detector will depend on the environment of car park.

    Lane barrier Design and other details will be discuss during the

    project planning and designUninterruptible Power System

    (UPS)At least 2 KVA; On-line UPS; Liebert ; outdoor type

    Bollard2 pairs: 1 pair protecting the card reader and 1 pair

    protecting the Unmanned Terminal Kiosk

    SignageDesign and content will be discussed during the

    project planning and design.

    Traffic System (Stop and Go)Design and location will be discussed during the

    project planning and design.

    Power System & Grounding

    System

    Design and location will be discussed during the

    project planning and design.

    Parking Cards RetailParker

    Smartcard ICs - MIFARE 13.56MHz frequency range

    VIP Parker 125KHz frequency range

  • 7/31/2019 Carparks Standards II Final as of 11292011

    13/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 13 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    Manned POS Exit Terminal

    MANNED POS EXIT TERMINAL SPECIFICATION / DETAILS

    Industrial POS Controller

    POS Parking Exit Terminal (Parking management and cashier station)

    CPU Pentium Dual Core T4400

    2.16G

    PE735 All-in-one Touch screen PC - LCD 17"

    screen WXGA Memory (RAM) 1G DDR2 - 160G SATA Hard Disk

    Drive ODD DVDRW - Chipset Intel 945GC Graphic Card GMA950(integrated) Acc: KB and Mouse MS Windows XP Pro; Antivirus, Ready On

    Card readerRead/write contactless IC card (MIFARE 13.56 MHz

    frequency range)

    Electronic Cash Drawer 24V

    Alphanumeric Customer Display

    POS PrinterThermal Printer/Paper Speed and other specifications to be defined by

    the respective PM/Proponent

    Uninterruptible Power System

    (UPS)

    At least 2 KVA; outdoor type Varies if the whole equipment's power

    requirements is higher than the set

    specification.

    Automatic Parking Barrier

    Design and location will be discussed during the

    project planning and design.

    Vehicle loop detector / sensor

    with loop cable system

    Proximity reader (60cm - 90cm or

    more) - 125 KHz frequency rangeCCTV Camera System

    Intercom System

    Traffic System (Stop and Go)

  • 7/31/2019 Carparks Standards II Final as of 11292011

    14/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 14 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    Back-End Server Terminal

    BACK-END SERVER

    TERMINALSPECIFICATION / DETAILS

    Computer Set (Server -

    Industrial Type) CPU (Central

    Processing Unit)

    IBM System x3500 M3

    * 5U tower with optional rack-mount capability

    * Up to two six-core Intel Xeon X5690 3.46 GHz

    processors or four-core Intel Xeon X5687 3.60 GHz

    processors (configure to order only) with 12 MB of cache

    per processor socket

    * 1333 MHz, DDR-3 registered DIMM memory

    * Up to seven high-performance PCIe I/0 slots standard,

    additional two PCI-X slots available via configure to order

    only (requires the removal of one standard PCIe I/O slot).

    * Supports up to eight or 16 small form factor (2.5") hot-

    swap Serial Attached SCSI (SAS) or Serial ATA (SATA) hard

    disk drives (HDDs) standard; additional options available to

    support maximum 24 SFF 2.5" SAS/SATA HDDs; up to four

    3.5" simple-swap SATA HDDs or up to eight 3.5" hot-swapSAS or SATA HDDs (available via configure to order only).

    * 6 Gbps RAID and 3 Gbps adapters standard

    KVM (Keyboard, Video (Monitor, Mouse) Keyboard USB Type Monitor17 LED Mouse USB Type

    Operating System MS Windows Server 2008 - Standard w/ 5 CAL MS Windows Server CAL 2008 CAL

    Database System Microsoft SQL Server 2008 (Standard)

    UPS (Uninterruptible

    Power Supply) Online; 5KVA; Rack MountPower System with

    Grounding System

    Server Room with Cooling

    System

    DVR Controller

    Storage Server / File Server

  • 7/31/2019 Carparks Standards II Final as of 11292011

    15/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 15 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    Back-Office Terminal

    BACK-OFFICE TERMINAL SPECIFICATION / DETAILS

    Computer Set (Desktop -

    Industrial Type)ALI/APMC Desktop Standard.

    CPU (Central Processing Unit)

    Motherboard

    Processor Memory (RAM) Hard Disk Power Supply Video Card Audio Card LAN Card Modem Card

    KVM (Keyboard, Video (Monitor), Mouse) Keyboard Monitor

    MouseDVD Reader & Writer

    Speaker with Amplifier and Microphone System

    Software MS Windows 7 Standard MS Office 2007 Standard Antivirus System

    Intercom System

    Card Reader / Writer EZ Wave MiFare Reader / Writer

    Promag VIP Card Writer

    UPS (Uninterruptible Power

    Supply)

    APC Smart UPS; at least 420VA; Minimum of 5

    outletsPrinter HP Laserjet Printer

  • 7/31/2019 Carparks Standards II Final as of 11292011

    16/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 16 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    Slot Display

    SLOT DISPLAY REMARKS

    Main Entrance Slot Display

    Main Entrance Slot Display w/ Sub Level

    Summary Metal Casing w/ Cooling System 5100 Data Terminal Slot Controller w/ I/O Circuit

    Vehicle Loop Detector w/ Loop Cable or Sensor

    Per level Slot Display (Optional

    for Building Car parks)

    Per Level Slot Display Metal Casing w/ Cooling System 5100 Data Terminal Slot Controller w/ I/O Circuit Vehicle Loop Detector w/ Loop Cable or Sensor

    PMS Software/Application

    PMS SOFTWARE/APPLICATION REMARKS

    Unmanned Entrance w/ Ads display management With Reporting and analytics to bedefined by the respective

    PM/Proponent

    Back-End (Server and Back-Office)

    POS Exit System

    Network Structured Cabling

    NETWORK STRUCTURED

    CABLINGSPECIFICATION / DETAILS

    Data cabling (Cat6)with at least 25 years product warranty (ex. Siemon /

    Systemax / Belden)

    Rack and Accessories

    - Closed Data Cabinet with cooling system

    - 14RU, black color, tainted glass (front door)

    - with PDU minimum of 10 outlets

    - 110 terminal block for tel. lines

    - Cable Manager- Patch Panel

    Roughing-ins -

    Managed Cisco Catalyst

    2960 Switch

    24 port with at least 2 fiber module; 10/100; 1RU;

    Software/Drivers;

  • 7/31/2019 Carparks Standards II Final as of 11292011

    17/17

    Section: PRODUCT REALIZATION PROCESSFACILITIES MANAGEMENT

    FMD-WI-11-02.33.3B

    Subject: WORK INSTRUCTIONSCar Parks Technical

    Standards II (Parking Accessories and Traffic Control)

    Revision Code: 0 Page 17 of 17

    Effectivity: 1 December 2011Prepared By:

    PVBasaya/RCCarreon

    Reviewed By:

    SGVinoya

    Approved By:

    RTMenpin/RMIrlanda

    QUALITY, ENVIRONMENTAL, HEALTH & SAFETYMANAGEMENT SYSTEM

    WORK INSTRUCTION

    Ayala

    Property

    ManagementCorporation

    References:

    Parking Management (The Next Level), Vol. 2, Parking 101 Series, International Parking Institute Road Works Safety Manual, Department of Public Works and Highways, Jan 2004

    Road Signs and Pavement Markings Manual, Department of Public Works and Highways, Jan 2004

    Manual on Uniform Traffic Control Devices (MUTCD)

    National Building Code