Upload
patricia-shugart
View
235
Download
5
Embed Size (px)
DESCRIPTION
Carolina Chemistries Catalog
Citation preview
Catalog
2012
Wake Forest Biotech Place575 N. Patterson Avenue, Winston-Salem, NC 27101 • 877-722-8910 or 336-722-8910 • fax 336-722-8915
www.carolinachemistries.com
Olympus® AU640 and AU400 Systems
When purchasing a chemistry analyzer you really only have two choices: New or Used
Call 1-877-722-8910 for more information.
www.carolinachemistries.comwww.carolinachemistries.com
Refurbished by Carolina Chemistries
New Used Barcoded Reagents √ √
Warranty 1 year 1 year
Established Peer Group √ √
Service >$15,000 <$15,000
Installation and Training √ √
Refurbished Olympus systems by Carolina Barcoded ready-to-use reagents by Carolina On-site installation and training by Carolina Established peer group by Carolina Warranty and service by Carolina
Olympus 640&400 flyer.indd 1 3/9/11 8:04:53 AM
Analytical system Fully automated, for routine, STAT, urine and homogeneous immunoassays
Analytical methods Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE
Simultaneously 48 photometric tests, 51 with ISE processed analytes
Throughput 800 photometric tests/hour; maximum of 1,200 with ISE
Sample feeder Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 150 samples; continuous loading
Sample tubes In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm
STAT samples Up to 22 positions for STAT samples, bar coded primary tubes
Sample volume 2 – 50 μl in 1 μl steps (1 – 50 μl for repeats)
Reagent supply 48 positions for R1 and R2; refrigerated (4 °C – 12 °C)
Reagent volume 1. reagent: 25 – 300 μl; 2. reagent: 25 – 300 μl; (in 1 μl steps)
Total reaction volume 150 – 550 μl
Reaction cuvette Quartz cuvettes
Reaction time Up to 8 minutes, 40 seconds
Reaction temperature 37 °C
Mixing method With rotating paddles after dispensing sample and reagent
Photometry system Direct assay through the reaction cuvette (0 – 2.5 OD) mono, bichromatic measurements possible
Wavelength 13 different wavelengths between 340 – 800 nm
Cuvette cleaning Comprehensive cleaning with detergents
Calibration Auto calibration, cooled calibrator positions
Test requisition Individual and profile test requisition via on line, mouse, functions keys or touch screen
Safety Clot detection and crash prevention for sample and reagent dispenser
Software Windows-NT®
On-line Full uni- and bidirectional communication possible
Quality control Auto QC, cooled QC positions
Dimensions (W x H x D) 74” x 50” x 32”
575 N. Patterson Avenue, Suite 430, Winston-Salem, NC 27101800-471-7272 or 336-722-8910 • fax 336-722-8915
Fully automated, for routine, STAT, urine and homogeneous Immuno Assays
Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE
Up to 38 photometric tests + 3 ISE
400 photometric tests/hour; maximum of 800 with ISE
Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 80 samples; continuous loading
In primary and secondary tubes; diameter from 11.5 to 16 mm; height from 55 to 102 mm
Up to 22 positions for STAT samples, bar-coded primary tubes
2 – 50 μl in 1 μl steps (1– 50 μl for repeats)
Refrigerated (4 °C – 12 °C); 76 positions for R1/ R2
1. reagent: 25 – 300 μl; 2. reagent: 25 – 300 μl; (in 1 μl steps)
150– 550 μl
Quartz cuvettes
Up to 8 minutes, 40 seconds
37 °C
With rotating paddles after dispensing sample and reagent
Direct assay through the reaction cuvette (0 – 2.5 OD) mono-, bichromatic measurements possible
13 different wavelengths between 340 – 800 nm
Comprehensive cleaning with detergents
Linear and non linear (linear interpolation), refrigerated calibrator positions
Individual and profile test requisition via on-line, mouse, function keys or optional touch screen
Clot detection and crash prevention for sample and reagent dispenser
Windows-NT®
Full uni- and bidirectional communication possible
57.1” x 47.6” x 29.9”
Specifications AU640 AU400
clc-olym.v1-02/12
Olympus 640&400 flyer.indd 2 3/9/11 8:04:53 AM
Carolina Liquid Chemistries reagents for use on Olympus® AU400, AU640, AU2700 & AU5400 Systems
Call 1-877-722-8910 for more information.
www.carolinachemistries.comwww.carolinachemistries.com
Barcoded liquid ready-to-use• Barcodeallowsuseofwithinlotcalibrationfeature
• Barcodetracksreagentposition,expiry,andlotnumber
• Pre-filledliquidready-to-useR1andR2cartridges
• On-boardstabilityof30days
Unique chemistries• CO2–14-daycalibrationstability
• Enzymes–don’trequiredailyblank
• Homocysteine–lowcostenzymatic
• HbA1c–singlechannel
• Lithium–lowcoststablereagent
Full line of reagent tests• Menuof60differentchemistries
• BarcodedDrugsofAbusetestsincluding:
Oxycodone,Burprenorphineand6-Acetylmorphine
• Completelineofmulti-calibratorsandcontrols
• Ferritin,Transferrin,Lp(a),CRP
• ServiceforAUSystems
clc-olymrgnt.v1-02/12
General Chemistries Item # Description
ALB AU-224 3 x 250 tests
ALP AU-206 3 x 250 tests
ALT AU-240 3 x 250 tests
AST AU-241 3 x 250 tests
Amylase AU-227 3 x 100 tests
APO A1 AU-632 3 x 200 tests
APO B AU-633 3 x 200 tests
BUN AU-252 3 x 300 tests
CA AU-251 3 x 300 tests
CHOL AU-211 3 x 200 tests
CK AU-207 3 x 250 tests
CO2 w/cal AU-313 3 x 250 tests
CREA AU-243 3 x 300 tests
CRP hs AU-645 3 x 100 tests
Cystatin-C AU-691 2 x 100 tests
DBIL AU-229 3 x 200 tests
Ferritin AU-694 3 x 100 tests
Fructosamine w/cal AU-612 3 x 80 tests
GGT AU-209 3 x 300 tests
GLU AU-208 3 x 250 tests
HbA1c w/Lyse AU-300 1 x 200 tests
HDLD w/cal AU-616 3 x 250 tests
Homocysteine w/cal AU-201 1 x 150 tests
Homocysteine w/cal Axis Shield AS-201 1 x 150 tests
Insulin AU-614 1 x 200 tests
Iron w/cal AU-618 3 x 200 tests
LDH AU-205 3 x 300 tests
LDLD w/cal AU-661 3 x 250 tests
Lipase w/cal AU-621 3 x 100 tests
Lithium w/cal AU-654 1 x 200 tests
Lp(a) AU-204 3 x 400 tests
Microalbumin AU-662 2 x 100 tests
MG AU-220 3 x 200 tests
PO4 AU-218 3 x 200 tests
Rheumatoid Factor AU-629 3 x 100 tests
TBIL AU-228 3 x 300 tests
TIBC (direct) AU-659 3 x 100 tests
TP AU-217 3 x 250 tests
Transferrin AU-641 3 x 100 tests
TG AU-213 3 x 250 tests
URIC AU-212 3 x 300 tests
Barcoded Reagents for use on Olympus Chemistry Systems
Drugs of Abuse Item # Description
Alcohol w/cal AU-421 2 x 625 tests
Amphetamine (AMPH) AU-412 2 x 625 tests
Barbiturate (BARB) AU-417 2 x 625 tests
Benzodiazepine (BENZ) AU-418 2 x 625 tests
Buprenorphine (BUP) AU-424 2 x 600 tests
Cannabinoid (THC) AU-410 2 x 625 tests
Cocaine (COCM) AU-413 2 x 625 tests
Ecstasy (XTSY) AU-423 2 x 625 tests
Methadone (METD) AU-415 2 x 625 tests
Opiate (OP) AU-411 2 x 625 tests
Oxycodone (OXY) AU-419 2 x 625 tests
Phencyclidine (PCP) AU-414 2 x 625 tests
Propoxyphene (PROX) AU-416 2 x 625 tests
6-Acetylmorphine (6AM) AU-425 2 x 600 tests
ISE Reagents Item # Description
Buffer AUH1011 4 x 2000 mL
Cleaning Solution AUH1019 4 x 100 mL
High Serum Standard AUH1015 4 x 100 mL
Low/High Urine Standard AUH1016 4 x 100 mL
Low Serum Standard AUH1014 4 x 100 mL
Mid Standard AUH1012 4 x 2000 mL
Na/K Selectivity Ck Solution AUH1018 2 x 25 mL
Reference AUH1013 4 x 1000 mL
Wash Concentrate CC160 2000 mL
InstrumentsRefurbished AU400 and AU640 chemistry analyzers with one-year warranty include installation and training.
ServiceAU400 and AU640 chemistry analyzers include one-year service agreement with annual PM, parts, labor, and hotline support
Wake Forest Biotech Place575 N. Patterson Avenue, Suite 430Winston-Salem, NC 27101800-471-7272 or 336-722-8910 • fax 336-722-8915
carol inachemistr ies .com
Routine chemistry. Special chemistry. Drugs of abuse.
BioLis 24iChemistry Analyzer
BioLis 24iChemistry Analyzer
510K Pending
carol inachemistr ies .com
3
• Discrete, random access, fully automated
• 400 tests per hour
• 100 chemistry tests available
• Requires no disposable cuvettes
• Barcoded sample tubes and reagents
• Barcoded ready-to-use reagents
• Bidirectional interface with host query
• Electrolytes by ion selection electrodes
• 30-day onboard reagent stability
• 14-day calibration stability (most analytes)
• 24-hour reagent cooling
• Less operational noise
• STAT capabilities
• Wavelength 340-800 nm
• Automatically tracks reagent stability and position
• Controls assayed for Carolina Chemistries reagents with peer group survey
BioLis 24iChemistry AnalyzerBioLis 24iChemistry Analyzer
The versatility of use in varying laboratory environments puts the BioLis 24i above all others in its class.
4
carol inachemistr ies.com
BioLis 24i Chemistry Analyzer Test MenuAcetaminophenAcid PhosAlbuminAlcoholAlk PhosALTAmikacinAmmoniaAmphetamineAmylaseAPO A1APO BASOASTBarbiturateBenzodiazepineBUNBUN, urineC3C4CalciumCalcium, urineCannabinoidCarbamazepineChlorideChloride, urineCholesterolCholinesteraseCKCK-MBCO2CocaineCotinineCreat, urineCreatinineCRP
CRP wide-rangeCystatin CD-dimerDigoxinDirect BilirubinEnzymaticFibrinogenFructosamineGentamicinGGTGlucoseGlucose, urineGlycoMark™
HaptoglobinHBDHDL-directHbA1cHomocysteinehsCRPIgAIgGIgMInsulinIronLactateLP(a)LDHLDL-directLidocaineLipaseLithiumMagnesiumMethadoneMethaqualoneMicroalbuminNAPAOpiate
OxycodonePancreatic AmyPhenobarbitalPhenytoinPhosphorusPhosphorus, urinePlac® TestPotassiumPotassium urinePrealbuminPrimidoneProcainamidePropoxypheneQuinidineRFSalicylateSodiumSodium,urineTDMsTheophyllineThyroxine (T4)TIBCTIBC DirectTobramycinTotal Bile AcidsTotal BilirubinTotal Protein, urineTransferrinTricyclicTriglyceridesT-UptakeUIBCUric AcidUric Acid, urineValproic AcidVancomycinPlac® Test is a registered trademark of diaDexus.
DRUGS OF ABUSE6-AMAlcoholAmphetamine (AMPH)Barbiturate (BARB)Benzodiazepine (BENZ)BuprenorphineCannabinoid (THC)Cocaine (COCM)Cotinine AssayEcstasy EIA Kit ETGMethadone (METD)Opiate (OP)OxycodonePhencyclidine (PCP)Propoxyphene (PROX)TCA (Tricyclics)
Adulterants Adulterant Cals & ControlsAldehydeCromate reagentHalogenNitriteOxidantpH reagent Spec GravityUrine Creatinine
The BioLis 24i has the most extensive menu of the benchtop chemistry analyzer market.
5
System function: Fully automated, discrete, random access chemistry analyzer with water system.
Analysis: Number of test items onboard: 36+3 (ISE)
Throughput: 240 photometric plus 160 ISE, 400 tests/hour
Analysis method: Endpoint, rate, ISE, Turbidimetry
Stat interruption
Calculated results
Auto dilution and rerun of out-of-range results
Sample pre-dilution (1/10)
Antigen excess detection
Sample handling: Sample type: Serum, plasma, urine, CSF
Sample container: Sample cup, primary tube (5, 7, 10 ml)
Number of samples onboard: 55 position sample tray
3 to 30µL sample size
Sample volume level detection
STAT capabilities: STAT sample priority
Reagents: Number onboard: 36 tests onboard
Liquid ready-to-use
Barcoded
Tracks test remaining
30-day onboard stability
Calibration: Chemistry – 14-day stability
ISE – 24-hour stability
Single point, multi-point
Linear, spline, logit-log
Reaction System: Optical source: Bi-chromatic
Automatic, discrete, random access
Automatic cell blank correction
Optical source: Tungsten halogen lamp
Optical measurement: Wavelengths – 340, 380, 405, 505, 546, 570, 600, 700, 750 and 800 nm
Cuvette material: 60 self-cleaning semi-permanent cuvettes
Reaction: Displays graphic reaction curve
Cuvette washing: Alkaline, acid, automatic 10-step, high temp, cuvette washing
Reagent mixing: Dual chamber cuvette reagent mixing
User interface: Software: Windows® XP based
Bidirectional LIS interface – RS-232
Automatically programs patient ID and tests
Barcodes – Code 39, Code 128, ITF, NW-7
Levy Jennings QC monitoring
Water, wash and waste alarms
Water/drain – self contained
Preventative maintenance screen
Power supply: AC 100/115/230 volt (50/60 Hz)
Dimension: 31.5” x 26.5” x 20.5” (W x D x H)
Weight: Approx. 210 lbs.
Warranty: One year
Support: 877-722-8910
Wake Forest Biotech Place , 575 N. Patterson Avenue, Suite 430, Winston-Salem, NC 27101 • 877-722-8910 or 336-722-8910 • fax 336-722-8915
BioLis 24iChemistry Analyzer
Technical Specifications
BioLis 24iChemistry Analyzer
Technical Specifications
BioLis24i.rv1dgtl.0212
6
www.carolinachemistries.comwww.carolinachemistries.com
Carolina STAT LabLab automation has real advantages, until it comes to running STATs.
www.carolinachemistries.comwww.carolinachemistries.com
ChemistryCLC 480 • 400testperhour • 30dayonboardreagent
stability • 100testmenu • Barcodedreagents • Bidirectionalinterface • Reusablecuvettes
HematologyMindray BC-3200 • Three-partdifferentialofWBC,
16parameters+3histograms • Automaticdiluting,lyzing,mixing,
rinsingandunclogging • Microsamplingof13μl • Oneminuteperanalysis • Datastorageof35,000samples
withhistograms • (Otheroptionsavailable)
ImmunoassayTosoh 360/600II • Troponin,CKMB,HcG,Myoglobin,
CystatinC • 40testmenu-anemia,markers,
thyroid,etc. • Primarytubesamplingbidirectional
interface • (Otheroptionsavailable)
LabTrak LIS • 3interfacesincludedforchemistry,hematologyandimmunoassay • LISandEMRinterface • Ensurescompliancewithallpertinentregulations • Cumulativereportofpatients’lastsixvisitsdisplayononepage
877-722-8910
STAT06.11
Carolina STAT Lab – Closer to the definition of STAT than ever before.Carolina STAT Lab – Closer to the definition of STAT than ever before.
Less than 60” of counter space
30 min 1 hr 2 hr 3 hr
Lab Automation Track
Carolina STAT Lab
The Carolina STAT Lab – the industry’s most comprehensive menu in less than 60” of counter space.
• Resultsinlessthan30minutes • Idealforurgentcare,smallhospitalsand physicianlabs • Fastertimetodiagnose • Fastertimetotreat • Improvedpatientexperience