Carbon Monoxide Monitoring
Presented by: Interscan Corporation
SYNONYMS
•Coal gas•Carbon oxide•Carbonic oxide•Exhaust gas•Flue gas•Monoxide
CARBON MONOXIDE
CARBON MONOXIDE IS THE MOST COMMON TOXIC GAS
As a product of combustion, it is ubiquitous
CO is one of the few toxic gases that can be encounteredat home or on the job
Colorless and odorless, CO is a silent killer
CO HEALTH EFFECTS
At 200-300 ppm, can cause fatigue in healthy individuals, and chest pain in those with heart disease.
At higher concentrations, can cause impaired vision and coordination; headaches; dizziness; confusion; nausea.
Can cause flu-like symptoms (ca. 250 ppm) that clear upwhen in clean air.
At 2000 ppm, can be rapidly fatal
TOXICOLOGY
Carbon monoxide is an asphyxiant
Inhalation of CO causes tissue hypoxia by preventing the blood from carrying sufficient oxygen
Carbon monoxide combines reversibly with hemoglobin to form carboxyhemoglobin
The reduction in oxygen-carrying capacity of the blood is proportional to the amount of carboxyhemoglobin formed
Occupational Exposure Standards
OSHA Standards (as of Feb, 2011)
The OSHA PEL ( Permissible Exposure Limit, based on an 8-hour time-weighted average) is 50 ppm
Special provision for maritime workers/longshoring [29 CFR 1918.94(a)(1)(i))]
…employees shall be removed from the enclosed space if the CO concentration exceeds a ceiling of 100 ppm.
Exception: The ceiling shall be 200 ppm instead of 100 ppm for Ro-Ro operations.
ACGIH TLV® [Threshold Limit Value]
(as of Feb, 2011)
TLV-TWA (based on an 8-hour time-weighted average) is 25 ppm
Biological Exposure Index (BEI®) is recommended for carbon monoxide ─
Based on percent carboxyhemoglobin saturation in blood, or end-expired CO concentration in alveolar air
NIOSH REL [Recommended Exposure Limits]
(as of Feb, 2011)
TLV-TWA (based on an 8-hour time-weighted average) is 35 ppm
Ceiling value of 200 ppm (should not be exceeded at any time)
NIOSH IDLH [Immediately Dangerous to Life and Health]
(as of Feb, 2011)
IDLH: The airborne concentration from which a worker could escape without injury or irreversible health effects, in the event of the failure of respiratory protection equipment.
IDLH values are based on effects that might occur as a consequence of a 30-minute exposure.
Regardless of the 30-minute basis, if equipment failure occurs,LEAVE THE AREA AT ONCE!!
1200 ppm
GRADE “D” BREATHING AIR Per ANSI / CGA G-7.1.1989
As it pertains to carbon monoxide…
No more than 10 ppm
Applications Engineering
AT A MINIMUM, CONSIDER
Portable/survey or fixed continuous monitoring requirement?
Interfering gases present?
Will unit be used/installed in electrically hazardous area?
Is data logging needed?
Some Carbon Monoxide Monitoring Products
Offered By
PORTABLE ANALYZER
CONTINUOUS MONITORING SYSTEMSINGLE POINT APPLICATION
CONTINUOUS MONITORING SYSTEMTWO POINT APPLICATION
CONTINUOUS MONITORING SYSTEMMULTI-POINT (THREE OR MORE) APPLICATION
For Survey Applications,We Recommend Our Nomad Data Logger
12-bit resolution
Models available for 0-100mV, 0-2.5Vand 4-20mA inputs
Self-contained units also available for temperature, humidity and pH
Sampling rate adjustable—1 second to 10 hours in 1 second intervals
Storage capacity—16336 readings
Excellent software included
Visualize your measurement session with an auto-scaling time history graph
Time history graph detail screen
Zoomed in on particular portion of the curve
Ability To View All Individual Data Points
ARC-MAX® DATA ACQUISITION, ARCHIVING,
AND REPORTINGPACKAGE
ARC-MAX® is designed to meet and exceed all toxic gas regulatory reporting requirements
Protect your employees…AND your company!
Only ARC-MAX® gives you
Shift reports, supporting up to four shifts/day, and the shifts can overlap
Alarm logs, updated as alarms occur
Live and historic trending
STEL and TWA tracking, continuously updated
ARC-MAX® MAIN SCREEN
ARC-MAX® SHIFT REPORT
ARC-MAX® TRENDING
ARC-MAX® ALARM LOG
For more information on how Interscan can help you solve your carbon monoxide problems,
Visit our website
http://www.gasdetection.com