4
Nihon Kohden End-Tidal CO 2 solutions span the continuum of care. cap- ONE ® Capnography Small, simple, more effective 1,2

cap-ONE Capnography - Nihon Kohden€¦ ·  · 2017-08-08stream capnography carry a substantial risk 2of CO 2breathingre ... , Anesthesiology, September 2009, 111(3): 609-15 2. Phillips

Embed Size (px)

Citation preview

Page 1: cap-ONE Capnography - Nihon Kohden€¦ ·  · 2017-08-08stream capnography carry a substantial risk 2of CO 2breathingre ... , Anesthesiology, September 2009, 111(3): 609-15 2. Phillips

Nihon Kohden End-Tidal CO2 solutions span the continuum of care.

cap-ONE®CapnographySmall, simple, more effective1,2

Page 2: cap-ONE Capnography - Nihon Kohden€¦ ·  · 2017-08-08stream capnography carry a substantial risk 2of CO 2breathingre ... , Anesthesiology, September 2009, 111(3): 609-15 2. Phillips

Small & Simple

Partnumber:

Deadspace:

Partnumber:

Deadspace:

Partnumber:

Deadspace:

YG-272TAdult

7mL

YG-282TAdultLarge

10mL

YG-242TInfant

2.5mL

YG-232TPediatric

3.5mL

YG-225TAdult

1.1mL

YG-235TPediatric

1.1mL

Non-Intubated Adapters for Patient MonitoringMaskshaveoxygen

Non-Intubated Adapters for Sleep Studies With Pressure

Intubated Adapters For Patient Monitoring

YG-214T

1.8mL

YG-213T

0.5mL

YG-211T

4mL

Sensor TG-980P Smart Cable

Verysoftmaskmaterialsandnasalpositionersforoptimalpatientcomfort

Page 3: cap-ONE Capnography - Nihon Kohden€¦ ·  · 2017-08-08stream capnography carry a substantial risk 2of CO 2breathingre ... , Anesthesiology, September 2009, 111(3): 609-15 2. Phillips

End-Tidal CO2 Measurement

Partnumber:

Deadspace:

Partnumber:

Deadspace:

Partnumber:

Deadspace:

SensorTG-920P Smart Cable

TG-921T3 Round Connector (for JE-921A & JE-120A)

YG-122TOral/Nasal

1.2mL

Non-Intubated Adapters for Patient MonitoringOral/nasaladapterhasoptionaloxygen:useHudsonRCI#1103oxygencannula

Non-Intubated Adapters for Sleep Studies With Pressure

Intubated Adapters for Patient Monitoring

YG-111T

4mL

YG-135TPediatric

1.2mL

YG-125TAdult

1.2mL

TheminiaturizedmainstreamsensorworksdirectlywithNihonKohdenmonitors,justplugintoasmartport,thetechnologyisbuiltintothemonitor—plugandmeasure!

Page 4: cap-ONE Capnography - Nihon Kohden€¦ ·  · 2017-08-08stream capnography carry a substantial risk 2of CO 2breathingre ... , Anesthesiology, September 2009, 111(3): 609-15 2. Phillips

More Effective1,2

Mainstream Performed Better than Sidestream1

• Mainstreamtechnologymeans themeasurementistakendirectlyat thelocationofexpiredCO2

1

• InastudybyKasuyaetal,Mainstream Capnographyperformedbetterthan sidestreamwhetherornotthere wasanoralguidewiththesidestream method1

Improved Oxygen Delivery 2

• cap-ONEMasksshowedimprovedoxygen deliveryvs.traditionaloxygenmaskswith sidestreamcannula2

• Masksfeatureanopenairdesignwhile deliveringO2andincorporating capnographyforaccurateend-tidal CO2readings2

• Standardoxygenmasksusedwithside- streamcapnographycarryasubstantial riskofCO2rebreathing2

• StandardO2masksdonotprovide adequateCO2removal2

•Non-intubatedadapterscaptureboth oralandnasalCO2

•Simpletousewithsnaponmainstream sensors

•Maskisasimpleandfastsolutionfor proceduralsedation

•Long-lastingsolution,adapterslast24 to72hours

DifferentThinkingforBetterHealthcare.®

DifferentThinkingforBetterHealthcareisaregisteredtrademarkofNihonKohden.cap-ONEisaregisteredtrademarkofNihonKohdenCorporation.

us.nihonkohden.com

MMLB128(A)-CO-1176

1.KasuyaY,AkcaO,SesslerDI,OzakiM,KomatsuR,AccuracyofPostoperative End-tidalPco2MeasurementswithMainstreamandSidestreamCapnography inNon-obesePatientsandinObesePatientswithandwithoutObstructive SleepApnea,Anesthesiology,September2009,111(3):609-15

2.PhillipsJS,PangilinanLP,MangalindanER,BoozeJL,KalletRH,AComparison ofDifferentTechniquesforInterfacingCapnographyWithAdultandPediatric SupplementalOxygenMasks,RespiratoryCare,January2017,62(1):78-85