Upload
catalincc
View
244
Download
0
Embed Size (px)
DESCRIPTION
-
Citation preview
CatalogApril
2004
Cam switchesComplete products 10 A
3 Schneider Electric
General Cam switches 0
Complete products 10 A
The range of K10 cam switches (10 A rating) comprises only complete switches.These products are more specifically designed for process control applications:b compact size,b easy to integrate with other Ø 16 and Ø 22 mm units,b selection functions.
Complete products Front mounting switches
b OFF-ON switchesb stepping selector switchesb changeover switches
Single Ø 16.3 or Ø 22.3 mm hole fixing
Mounting method Single Ø 16 or Ø 22 hole fixing
Locking/unlocking of the body-head assembly by means of a lug
Single Ø 16 hole fixing Single Ø 22 hole fixing
1
20
2
0
3
1
1
20
Characteristics :page 30051/3
References :pages 30051/4 to 30051/8
Dimensions :page 30051/9
4Schneider Electric
Characteristics Cam switches 0
Complete products, 10 AFront mounting, single Ø 16 or Ø 22 mm hole fixingWith 30 x 30 mm front plate
EnvironmentConforming to standards IEC/EN 60947-3
IEC/EN 60947-5-1
Approvals cULus
Protective treatment Standard version: “TC”
Ambient air temperature Operation: - 20…+ 55 °C
Storage: - 40…+ 70 °C
Electric shock protection Class II, conforming to IEC 60536
Degree of protection IP 65 conforming to IEC 60529 (operating head)IP 20 (contact block)
Mechanical durability 1 million operating cycles
Contact block characteristicsRated operational characteristics AC-15, A300 – 240 V 3 A
120 V 6 AAC-21A, AC-1 – 400 V 10 A
UL/CanadaHeavy DutyA300
3-phase 110/120 V 0.75 HP220/240 V 1 HP
Single-phase 110/120 V 0.33 HP220/240 V 0.75 HP
AC-23A 3-phase 220/240 V 1.8 kW
Single-phase 110/120 V 0.37 kW220/240 V 0.75 kW
d.c. current Ieresistive load
1 contact 24 V 10 A110 V 0.7 A220 V 0.3 A
Short-circuit protection Cartridge fuse 10 A gG
Conventional thermal current (Ith) 10 A
Rated insulation voltage (Ui) 440 V, degree of pollution 3 conforming to IEC 60947-1
Contact operation Slow break
Terminal referencing Conforming to CENELEC EN 50013
Rated impulse withstand voltage (U imp) 4 kV conforming to IEC 60947-1
Electrical reliability Failure rate < 1 failure, for 100 million operating cycles (c 24 V PLC inputs)
Cabling Screw and captive cable clamp terminalsClamping capacity: 2 x 1.5 mm2
Dimensions :page 30051/2
References :pages 30051/4 to 30051/8
Dimensions :page 30051/9
5 Schneider Electric
References Cam switches 0
Complete products, 10 AFront mounting, single Ø 16 or Ø 22 mm hole fixingWith 30 x 30 mm front plate
OFF-ON switchesWiring schemeandswitching scheme
Marking& switchposition
Numberofpoles
Reference Weight
kg
1 K10-A001ACH 0.030
2 K10-B002ACH 0.035
3 K10-C003ACH 0.045
4 K10-D004ACH 0.045
Stepping switches, single-pole, with “O” positionWiring schemeandswitching scheme
Marking& switchposition
Numberofpoles
Reference Weight
kg
2 + "0" K10-B002QCH 0.035
3 + "0" K10-C003QCH 0.045
4 + "0" K10-D004QCH 0.045
78
56
34
12
1 2 3 4
012345678
601-pole
2-pole
3-pole
4-pole
01
060
K10-B002ACH
5525
7
33012
30
34
270
12
L1
34
1 2
1
0
2
270
30330
12
L1
34
1 2
56
3
31512
0
34
1
34
270 45
56
12
30
0315 45
270
78
56
34
1 2 3 4
21
L1
3012
330300270
34
1234
0
5678
0 30330300270
42 310
K10-D004QCH
550
258
Dimensions :page 30051/2
Characteristics :page 30051/3
Dimensions :page 30051/9
6Schneider Electric
References (continued) Cam switches 0
Complete products, 10 AFront mounting, single Ø 16 or Ø 22 mm hole fixingWith 30 x 30 mm front plate
Stepping switches, 2-pole, with “O” positionWiring schemeandswitching scheme
Marking& switchposition
Numberofpoles
Reference Weight
kg
2 + "0" K10-D012QCH 0.045
3 + "0" K10-F013QCH 0.055
Stepping switches, single-pole, without “O” position
3 K10-C003NCH 0.045
4 K10-D004NCH 0.045
12
L1
34
1
5678
L2
2
33012
30
34
1234
270
5678
1
0
2
270
30330
5502
59
K10-D012QCH
1
12
L1
345678
L2
9101112
2 3
31512
0
34
1234
270
5678
45
9101112
12
30
0315 45
270
12
L1
34
1 2
56
3
33012
30
34
1234
270
56
2
1
3
270
30330
12
L1
34
1 2
56
3
78
4
33012
30
34
1234
270
56
90
78
32
41
30330
90270
Dimensions :page 30051/2
Characteristics :page 30051/3
Dimensions :pages 30051/9
7 Schneider Electric
References (continued) Cam switches 0
Complete products, 10 AFront mounting, single Ø 16 or Ø 22 mm hole fixingWith 30 x 30 mm front plate
Stepping switches, 2-pole, without “O” positionWiring schemeandswitching scheme
Marking& switchposition
Numberofpoles
Reference Weight
kg
3 K10-F013NCH 0.055
Changeover switch with spring returnWiring schemeandswitching scheme
Marking& switchposition
Numberofpoles
Reference Weight
kg
1 K10-B006TCH 0.035
Changeover switches with “O” position
1 K10-B001UCH 0.035
2 K10-D002UCH 0.045
3 K10-F003UCH 0.055
4 K10-H004UCH 0.065
Changeover switches without “O” position
1 K10-B011UCH 0.035
2 K10-D012UCH 0.045
3 K10-F013UCH 0.055
4 K10-H014UCH 0.065
270
30330
2
1
3
1
12
L1
345678
L2
9101112 2 3
33012
30
34
1234
270
56789101112
12
L1
1 2
L4
34
012
30
34
330
21 0
0330 30
5502
60
K10-B006TCH
12345678910111213141516 1 2
L/1 2 3 4
012
60
34
300
5678910111213141516
1-pole
2-pole
3-pole
4-pole
1 20
060300
K10-F003UCH
5502
61
12345678910111213141516 1 2
L/1 2 3 4
301234
330
5678910111213141516
1-pole
2-pole
3-pole
4-pole
21
30330
Dimensions :page 30051/2
Characteristics :page 30051/3
Dimensions :pages 30051/9
8Schneider Electric
References (continued) Cam switches 0
Complete products, 10 AFront mounting, single Ø 16 or Ø 22 mm hole fixingWith 30 x 30 mm front plate
Voltmeter switchesFor measurement between phases and between phase and neutralWiring schemeandswitching scheme
Marking& switchposition
Reference Weight
kg
K10-F027MCH 0.055
For measurement between phases, with “O” position
K10-D024MCH 0.045
Ammeter switches3 measurement points, with neutral position
K10-F003MCH 0.055
30012
330
34
270 0 30 60 90
56789101112
12
L1
345678
L3
9101112
L2 N
V
L1-L2 0 L1-NL2-L3L3-L1
L2-NL3-N
045315
135225
270 90
550
262
K10-F027MCH
12
L1
345678
L3L2
V
31512
0
34
270 45
5678
L2-L3L3-L1L1-L2
0
045315
270
123456789
101112
PEL3L2L1
A
9012
180
34
0 270
56789101112
0
2
3 1
270 90
0
180
550
263
K10-F003MCH
Dimensions :page : 30051/2
Characteristics :page 30051/3
Dimensions :pages 30051/9
9 Schneider Electric
References Cam switches 0
Complete products, 10 AFront mounting, single Ø 16 or Ø 22 mm hole fixingWith 30 x 30 mm front plateAccessories
Legend holdersDescription Sold
inlots of
Unitreference
Weight
kg
For Ø 22 mm hole fixing With metallicfinish legend
25 Z227N 0.060
AccessoriesDescription Colour Sold
inlots of
Unitreference
Weight
kg
Blanking plug Black 10 Z33 0.060
Nut wrench – 5 Z201 0.020
Z227N
5400
1650
1646
_1
Z33
5016
47_1
Z201
Dimensions :page 30051/2
Characteristics :page 30051/3
Dimensions :page 30051/9
10Schneider Electric
Dimensions Cam switches 0
Complete products, 10 AFront mounting, single Ø 16 or Ø 22 mm hole fixingWith 30 x 30 mm front plate
Cam switches 10 A
a
K10-A, B 51K10-C, D 63
K10-F 75K10-H 87
e : thickness of support 0.5 to 5.5 mm.
Single Ø 16 or Ø 22 mm hole fixing
Contact functions: how to understand the conventions usedLink positions (factory mounted)
Angular position of switch
Graphic representation of switching positions and spring return to “O” position
25 e
a
30 28
16,2
1,7
9,8
22,3
3,2
12,7
123456
L3L2L1
78910
WVU
045315
1234
450
5678
315
910 Contact terminal reference number
Contact closed
Contact closed in 2 positions and maintained betweenthe 2 positions
Sealed assembly for auto-maintain control
Overlapping contacts
Dimensions :page 30051/2
Characteristics :page 30051/3
References :pages 30051/4 to 30051/8
April 2004
9003
CT
0401Schneider Electric Industries SAS
Headquarters
89, bd Franklin Roosevelt F - 92506 Rueil Malmaison Cedex
http://www.schneider-electric.com
Owing to changes in standards and equipment, the characteristics given in the text and images in this document are not binding until they have been confirmed with us.
Production : Schneider Electric IndustriesPhotos : Schneider Electric IndustriesPrinted by : CCI