15
Calibrate Installation www.ais-inc.com 1 C-CHABSINSTALL Revision 11.09.2020 ***READ ALL INSTRUCTIONS BEFORE USING *** For commercial use only. Warning: Risk of Injury Maximum load 275 lbs. 2 leg, 325 lbs. 3 leg Electrical rating: 120V, 60Hz, 16 AMP No more than 12 furnishings can be connected on one branch circuit. IMPORTANT SAFETY INSTRUCTIONS DANGER To reduce risk of electric shock: Always unplug furnishing from the electrical outlet before cleaning. WARNING To reduce the risk of burns, fire, electric shock, or injury to persons: Unplug from outlet before putting on or taking off parts. Close supervision is necessary when this furnishing is used by, or near children, invalids or disabled persons. Use this furnishing only for its intended use as described in these instructions. Do not use attachments not recommended by the manufacturer. Never operate this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Keep the cord away from heated surfaces. Never operate the furnishing with the air openings blocked. Keep the air openings free of lint, hair and the like. Do not use outdoors. To disconnect, turn all controls to the off position, then remove plug from outlet. Connect to a properly grounded outlet only. See grounding instructions. For loading always put heavier items at the bottom and not near the top in order to help prevent the possibility of the furnishing tipping over. HAT Base with Storage

Calibrate Installation HAT Base with Storage - AIS

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 1C-CHABSINSTALL Revision 11.09.2020

***READ ALL INSTRUCTIONS BEFORE USING***

• For commercial use only.

• Warning: Risk of Injury – Maximum load 275 lbs. 2 leg, 325 lbs. 3 leg

• Electrical rating: 120V, 60Hz, 16 AMP

• No more than 12 furnishings can be connected on one branch circuit.

IMPORTANT SAFETY INSTRUCTIONS

DANGER – To reduce risk of electric shock:

• Always unplug furnishing from the electrical outlet before cleaning.

WARNING – To reduce the risk of burns, fire, electric shock, or injury to persons:

• Unplug from outlet before putting on or taking off parts.

• Close supervision is necessary when this furnishing is used by, or near children, invalids

or disabled persons.

• Use this furnishing only for its intended use as described in these instructions. Do not

use attachments not recommended by the manufacturer.

• Never operate this furnishing if it has a damaged cord or plug, if it is not working

properly, if it has been dropped or damaged, or dropped into water.

• Keep the cord away from heated surfaces.

• Never operate the furnishing with the air openings blocked. Keep the air openings free of

lint, hair and the like.

• Do not use outdoors.

• To disconnect, turn all controls to the off position, then remove plug from outlet.

• Connect to a properly grounded outlet only. See grounding instructions.

• For loading always put heavier items at the bottom and not near the top in order to help

prevent the possibility of the furnishing tipping over.

HAT Base with Storage

Page 2: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com

Revision Log

Date Page No. Description of change Name

11/9/2020 12-15 Updated control box and 90-degree cable S. Powers

2C-CHABSINSTALL Revision 11.09.2020

Revision Log

Page 3: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 3C-CHABSINSTALL Revision 11.09.2020

GROUNDING INSTRUCTIONS

This product is for use on a circuit having a nominal rating more than 120 volts and is

factory-equipped with specific electric plug to permit connection to a proper electric circuit.

Make sure that the product is connected to an outlet having the same configuration as the

plug. No adapter should be used with this product

HAT Base with Storage

Page 4: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 4C-CHABSINSTALL Revision 11.09.2020

Parts List

Item Replacement

Part number

Circle Sheet

Part Number

Description Image

1 O-HATDPB O-HATDBP HAT Plate

2 RH-SMZFP102B RH-SMZFP102B Flat Head Screw

#10 x 2” long

3 RH-WSFP1034-C RH-WSFP1034-C Flat Head Screw

#10 x ¾” long

4 RL-PLG RL-PLG Trim Ring

5 T-HAC T-HAC Cantilever

6 Pan Head Screw

M6 x 10mm

7 RL-HAC70xx

xx = BK (Black)

xx = MS (Silver)

xx = WT (White)

RL-HAC70xx

xx = BK (Black)

xx = MS (Silver)

xx = WT (White)

70mm Column

8 O-GSO OX-GSO Glide Plate

9 RH-91420A425 RH-91420A425 Flat Head Screw

M6 x 14mm long

10 RH-CGLIDE RH-CGLIDE ¼-20 Glide

11 RH-QS0978 RH-QS0978 Flat Head Screw

#9 x 7/8” Long

Page 5: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 5C-CHABSINSTALL Revision 11.09.2020

Parts List Cont.

Item Replacement

Part number

Circle Sheet

Part Number

Description Image

12 Pan Head Screw

M6 x 14mm long

13 WPS-FP RWPS-FP Flat Plate

14 T-HA-Txx

xx = 36 - 96

(6in increments)

RL-HA-Txx

xx = 36 - 96

(6in increments)

Trough

15 T-UCKxx

xx = 36-96

(6in increments)

RWPS-HSxx

xx = 36-96

(6in increments)

U-Channel

16 RL-2LCB RL-2LCB 2 Input Control Box

17 RL-3LCB RL-3LCB 3 Input Control Box

18 Pan Head Screw

#10 x 7/8” long

19 RL-2LCK90 RL-2LCK90 90° Cable Extension

1.3M long

20 RL-2LCK RL-2LCK Cable Extension 1.3M

21 RL-3LCK RL-3LCK Cable Extension 2.5M

22 RL-PHS RL-PHS Programmable Control

Pad

23 Pan Head Screw

#6 x ½” long

Page 6: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 6C-CHABSINSTALL Revision 11.09.2020

#10 x 2” long

Flat head screw

#2 Philips drive

6 places

HAT Plate

Align hole pattern on

HAT Plate to opening

on laminate base

or

Step 1:

Install HAT plate(s) to bottom of Calibrate storage pieces(s)

HAT Base with Storage

Step 2:

Install Trim Ring(s) to top of Calibrate storage pieces(s)

Trim Ring

#10 x 2” long

Flat head screw

#2 Philips drive

3 places

#10 x 3/4” long

Flat head screw

#2 Philips drive

3 places

1

2

2

3

4

Page 7: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 7C-CHABSINSTALL Revision 11.09.2020

M6 X 10mm

Machine Screw

Philips Drive #3

4 places

Cantilever

70mm Column

Step 3:

Install Cantilevers to Columns

HAT Base with Storage

Step 4:

Install Glide and Glide Plate (only for columns without storage or feet)

If Columns require a storage piece, skip this step and proceed to Step 5.

¼-20 Glide

Flat Head Screw

M6 X 14mm long

Hex drive: 4mm

4 places

Glide Plate

5

6

7

8

9

10

Page 8: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 8C-CHABSINSTALL Revision 11.09.2020

Step 5:

Install Worksurface(s)

2 5/16”

CL

Worksurface

#9 x 7/8” long

Flat head screw

#2 Philips drive

12 places

HAT Base with Storage

Step 6:

Install HAT Bases

M6 X 14mm

Machine Screw

Philips Drive #3

8 places

Orientate base

cabinet such that

the leg is inboard

toward the center

of the desk

OFFSET

Center of desk

11

12

Page 9: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 9C-CHABSINSTALL Revision 11.09.2020

Step 7:

Assemble Return Column

2 5/16”

#9 x 7/8” long

Flat head screw

#2 Philips drive

12 places

Return

Column

M6 X 14mm

Machine Screw

Philips Drive #3

4 places

Return

Step 8:

Assemble Return Base

LC

Orientate base

cabinet such that

the leg is inboard

toward the center

of the desk

OFFSETCenter of desk

HAT Base with Storage

11

12

Page 10: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 10C-CHABSINSTALL Revision 11.09.2020

HAT Base with StorageStep 9:

Install Flat Plates

Return

#9 x 7/8” long

Flat head screw

#2 Philips drive

4 places

Flat Plate

2 Places

Step 10:

Install trough(s) to worksurface. Symmetrically center

trough horizontally between the 2 columns.

(views shown here without storage for clarity)

Mount trough so

that this opening

is on user side

Align this edge with Cantilever

edge so that the trough is off-

centered from the worksurface

Trough

Length = Worksurface width – 20 1/8”

#9 x 7/8” long

Flat head screw

#2 Philips drive

6 places

Trough (return)

Length = Return width + 9”

11

13

14

11

14

Page 11: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 11C-CHABSINSTALL Revision 11.09.2020

HAT Base with StorageStep 11:

Install U-Channels (only for benches 60W and up)

#9 x 7/8” long

Flat head screw

#2 Philips drive

#9 x 7/8” long

Flat head screw

#2 Philips driveU-Channel

Length = Worksurface width - 24.5”

2 places

U-Channel

Length = Worksurface width - 24.5”

2 places

11

11

15

15

Page 12: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 12C-CHABSINSTALL Revision 11.09.2020

HAT Base with Storage

#10 x 7/8” long

Pan head screw

#2 Philips drive

2 places

2-Input Control Box

3-Input Control Box

#10 x 7/8” long

Pan head screw

#2 Philips drive

2 places

Step 12:

Install Control Box. (views shown here without storage for clarity)

1617

18

18

3 Leg configurations:

Use a 3-Input Control Box

2 leg configurations:

Use a 2-Input Control Box

Page 13: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 13C-CHABSINSTALL Revision 11.09.2020

HAT Base with Storage

Step 13a (2 Leg configurations):

Connect columns to control box. (views shown here without storage for clarity)

User Side

Connect Leg 2 to Port M2

(See Fig A below)Connect Leg 1 to Port M1

Use 90° 1.3M long cable extension

(See Fig B below)

12”

19

Fig B - CORRECT IN-CORRECTFig A

Page 14: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 14C-CHABSINSTALL Revision 11.09.2020

Connect Leg 1 to Port M1Connect Leg 2 to Port M2

• Use 1.3M cable extension

Connect Leg 3 to Port M3

• Use 2.5M cable

12” 20

21

Step 13b (3 Leg configurations):

Connect columns to control box.

HAT Base with Storage

Page 15: Calibrate Installation HAT Base with Storage - AIS

Calibrate Installation

www.ais-inc.com 15C-CHABSINSTALL Revision 11.09.2020

Programmable

Control Pad

#6 x ½” long

Pan Head Screw

#2 Philips Drive

4 places

Plug Control Pad into Port HS

Step 14:

Connect Control Pad.

HAT Base with Storage

22

23