Calculation 98-ENG-02405D2, Revision 2
Attachment 8
ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PMPe Page I of 32
BWT Dominion-Engineering Technical Evaluation
Cover SheetP, # / a,~ 31 IZ
S. S S *.~ .I
1. Stations Doc Type: Sub Type: 2. Document Number 3. Rev # 4. Decomissioning?[Z MP E] SU 5] NA E] KW [] CO ETE 000 ETE-MP-2012-1135 0 5 Yes f] No
(Note: If both SU and NA. then check CO)
5. Title:Justification for the Table Accuracy Value Used in the MINCo RTD SCA Term in Calculation No. 98-ENG-02405D2.6. ETE Level 7. Unit(s) * 8. Quality Classification 9. FSRC Approval Req.?[] Level El] Level 1 1 El Unit1 Ea Unit2 51 Unit3 l ISFSI El SR [] NS 5 NSQ 5 Yes [Z No
10.. Preparation, Review, and Approval Signatures (add or delete rows as needed)
Preparer : (Print) Signature: Date:Digitally Signed By: . 08/06/2012Nancy Nowlan 12:03:43 pm
Reviewer: (Print) Signature: Date:Digitally Signed By: 08/06/2012Konstantine Filippides - "-,, .-- 01:04:08 pm
Engineering Supervisor / Designee: (Print) Signature: Date:Digitally Signed By: 08/06/2012Keith Deslandes Xý__ z•__ 02:17:27 pm
Standard Attachments Attachment # of pages Reviewed/No Not Req.Impact
11. Design Effects and Considerations (DNES-AA-GN-1003) F-_ _ _*
12. Document Impact Summary (DRUL) (DNES-AA-GN-1002) __ *13. Considerations and Conditions for Document Updates (check N/A F7 if no document updates are noted on the DRUL)
5 All Document updates noted on the DRUL can be initiated immediately
5 Document updates noted on the DRUL are delayed until the following documents/actions are completed:
(e.g., WO, CR etc.) (See DRUL Remarks section)
1OCFR5O.59 Attachments Attachment # of pages Not Req.
14. 1OCFR50.59/72.48 applicability review forms (DNAP-3004 or CM-AA-400) Wk
15. 1OCFR50.59/72.48 screen form (DNAP-3004 or CM-AA-400) I•16. 1 OCFR50.59/72.48 evaluation form (DNAP-3004 or CM-AA-400) I217. Additional Attachments
Attachment # of pages DescriptionMET LAB RTD Cal UncertaintyCalc,, 1MET LAB RTD Cal UncertaintyInforn ICalibrationReport SN 1309.pdf 1CalibrationReport SN 1269.pdf 1CalibrationReport SN 1270.pdf 1MINCoAccuracyStatement.pdf 2SN_1269,_SN 1270 and SN 1309 C2 12
SN 1269 SN_1270 SN 1309_2009_1V 9 1
Aug 6, 2012 3:06 PM
ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 2 of 32
1'977X61-111460J7- 9.
Engineering Technical Evaluation
Cover SheetDomninion-
CMA'-T-0 ATTACHMENT .a l2o
18.DDistributionPrimary Recipient(s): (Enter the Name I Dept or Location for EACH Primary Recipient in this block.)
Copy To? Other Recipient / Department or Location Copy To? 1Other Recipient/Department or Location]J Preparer
[]J Reviewer
F] Supervisor
El Site DCE
[] iffected organization
El Program Owners
2.0 Source Document
Calculation No. 98-ENG-02405D2, "Millstone Unit 2 Service Water Inlet Temperature-Indicator Accuracy TI-6928, TI-6929 & TI-6930."
4.0 Purpose
The purpose of this engineering technical evaluation is to provide justification for the MINCo RTD "Table Accuracy" term used withincalculation no. 98-ENG-02405D2. Also, this engineering technical evaluation will contain the calibration tables for the calibrated RTDsTE-6928, TE-6929 and TE-6930.
Aug 6, 2012 3:06 PM
ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 3 of 32
A) •AcJi/I,/y/ 6Jr- •"
.u•,miionEngineering Technical Evaluation k(6 o r 3-ominion"Cover Sheet
CMAA-T 0 ATTACHMENT .a 3o
7.0 Discussion
TE-6928, TE-6929 and TE-6930 are the Vital AC Switchgear Room Cooling Coil (Xl 81A and X811B) Service Water Inlet RTDs. LoopsT-6928, T-6929 and T-6930 are used in technical specification surveillance SP 2619A, "Control Room Shift Checks," to record and verifythat the "Ultimate Heat Sink" temperature is less than 74.5 degrees F.
TE-6928, TE-6929 and TE-6930 are MINCo. model no. XS7927PKIL76S RTDs, serial nos. S/N 1309, S/N 1270 and S/N 1269,respectively. RTDs S/N 1269 and S/N 1270 were certified by MINCo in 1993 and RTD S/N 1309 was certified by MINCo in 2000.MINCo certified all three RTDs to a stated accuracy value of± 0.025 degrees C (refer to the attached MINCo "Report of Calibrations"and "MINCo Accuracy Statement"). This supported the SCA term used in calculation no. 98-ENG-02405D2, revision no. 0.
A subsequent calibration of these particular serial number RTDs was performed by the Millstone Metrology Lab in 2009. New R vs Ttables were generated and used for the calibration of each of the temperature loops (refer to the attached "SN 1269, SN 1270 and SN 1309Met Lab Calibration Curves"). Information provided by the Millstone Metrology Lab indicates that the standards used by the lab tocalibrate these RTDs is ± 0.0038 degrees C (refer to the attached "Met Lab RTD Cal Uncertainty Cales. And Met Lab RTD CalUncertainty Information). This uncertainty value bounds the A: 0.025 degrees C used in the SCA term in calculation no. 98-ENG-02405D2.
To ensure the Metrology Lab curves approximated those produced by MINCo, this ETE compared the values of the M]NCo curves to theMetrology Lab curves. The original R vs T tables provided by MINCo were not found. However, within MINCo's website, an RTDTable Generator was used to generate the R vs T tables using the coefficients of the original M1NCo RTD calibration reports. UsingEXCEL, R vs T curves were plotted using resistance and temperature values over the 0 to 100 degrees F calibrated span of thesetemperature loops in 5 degrees F increments (21 data points). Again using EXCEL, R vs T curves were plotted using the 2009 MetrologyLab generated tables for these RTDs. The two curves generated for each serial no. RTD were compared. The worst case error noted andexpressed as a percent of span (0 to 100 degrees F span) for S/N 1269, S/N 1270 and S/N 1309 was ± 0.033 % (± 0.033 degrees F), ±0.01 % (- 0.01 degrees F) and ± 0.066 % (± 0.066 degrees F), respectively. As stated earlier, S/N 1269 and S/N 1270 were certified byMINCO 16 years prior to the Metrology Lab calibration and S/N 1309 was certified by MINCo 9 years prior to the Metrology Labcalibraion. For S/N 1269 and S/N 1270, a MINCo stated 16 years drift term "root sum of the square" combined with the MINCorepeatability statement for this model no. RTD equates to ± 0.36 % (0.36 degrees F). For S/N 1309, a MINCo stated 9 years drift term"root sum of the square" combined with the MINCo repeatability statement for this model no. RTD equates to ± 0.27 % (0.27 degreesF). The worst case error in the curves generated by MINCo as compared to the 2009 Metrology Lab calibrations indicates that theseparticular serial no. RTDs did not drift very much over their respective 9 year and 16 year period and certainly much less than expected.
8.0 Conclusions
The ± 0.025 degrees C value used in the SCA term for RTD accuracy in calculation no. 98-ENG-2405D2 is valid. This value is used as"Table Accuracy" in revision no. 2 of this calculation.
Aug 6, 2012 3:06 PM
ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 4 of 32
A,7r~c/lA1e,~i-r gEngineering Technical Evaluation
Cover Sheet:ý) Fominion-CMA-T-0 ATTCHEN 2 * e4o
12.0 References
All references are attached to this ETE.
1. Calibration Report SN 1269,
2. Calibration Report SN 1270,
3. Calibration Report SN 1309,
4. MET LAB RTD Cal Uncertainty Calcs,
5. MET LAB RTD Cal Uncertainty Information,
6. SN 1269 SN 1270 SN 1309 Met Lab Cal Curves,
7. SN 1269, SN 1270, SN 1309 Calibration Curve Comparisons (EXCEL spreadsheets and charts),
8. MINCo Accuracy Statement.
Aug 6, 2012 3:06 PM
Attachment #1 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 5 of 32
,4/7%6/n'n6A"r a5-a- 3 2--
MINCO PRODUCTS, INC. REPORT No. 20137300 COMMERCE LANE JOB No. 03-30932FRIDLEY, MN 55432 P.O.# 259053TELEPHONE: (612) 571-3121FAX: (612) 571-0927
REPORT OF CALIBRATION*** CERTIFICATE **T*
FORPLATINUM RESISTANCE THERMOMETER
MODEL XS7927PKIL76S(B) SERIAL No. 1269PREPARED BY MINCO PRODUCTS, INC.
FOR NORTHEAST NUCLEAR ENERGY CO
THE THERMOMETER RESISTANCE WAS MEASURED AT FIXED TEMPERATUREPOINTS DEFINED BY ITS-90 OR BY COMPARISON WITH A CALIBRATEDPLATINUM RESISTANCE THERMOMETER TRACEABLE TO THE NATIONALINSTITUTE OF STANDARDS AND TECHNOLOGY. RESISTANCES WEREMEASURED WITH AN EXCITATION CURRENT OF 1.OmA.
TEMPERATURE IS DERIVED FROM MEASURED RESISTANCE AS FOLLOWS:
FOR TEMPERATURES BELOW 273.16K:Wref(T) = W(T) - a4*[W(T)-I] - b4*(W(T)-I)lnW(T)
FOR TEMPERATURES AT AND ABOVE 273.16K:Wref(T) = W(T) - a8*[W(T)-I] - b8*[W(T)-I]-2
WHERE W(T) R(T)/R(273.16K), FOR T IN KELVIN;Wref(T) DEFINES TEMPERATURE ACCORDING TO THEITS-90 REFERENCE FUNCTION (SEE FOLLOWING PAGE);AND THE COEFFICIENTS a4, b4, a8, AND b8 AREUNIQUE TO EACH INDIVIDUAL THERMOMETER.
a8 = -4.0758054D-04b8 = +8.3733738D-05a4 = -3.6445181D-04b4 = -2.8576799D-06
R(OC) = 199.872 OHMSR(100C)/R(OC) = 1.3927
MEASUREMENT DATATEMP (-C) RESISTANCE (OHMS)
-189.34 43.2061-38.83 168.742
0.010 199.880100.00 278.358231.928 378.273
MEASUREMENTS BY: D. JACOBSCERTIFIED BY: G. ENGELBRECHT
DATE CERTIFIED: 10 JUNE 1993
N.I.S.T. TEST REPORT No. 811/250375
DATE OF N.I.S.T. TEST: 4 DECEMBER 1992
Attachment #2 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 6 of 32
A4 7rACI/,'f C,, '-5-- 6 a
MINCO PRODUCTS, INC. REPORT No. 20147300 COMMERCE LANE JOB No. '03-30932FRIDLEY, MN 55432 P.O.# 259053TELEPHONE: (612) 571-3121FAX: (612) 571-0927
REPORT OF CALIBRATION*** C ERT I F I CATE ** *
FORPLATINUM RESISTANCE THERMOMETER
MODEL XS7927PK1L76S(B) SERIAL No. 1270PREPARED BY MINCO PRODUCTS, INC.
FOR NORTHEAST NUCLEAR ENERGY CO
THE THERMOMETER RESISTANCE WAS MEASURED AT FIXED TEMPERATUREPOINTS DEFINED BY ITS-90 OR BY COMPARISON WITH A CALIBRATEDPLATINUM RESISTANCE THERMOMETER TRACEABLE TO THE NATIONALINSTITUTE OF STANDARDS AND TECHNOLOGY. RESISTANCES WEREMEASURED WITH AN EXCITATION CURRENT OF 1.OmA.
TEMPERATURE IS DERIVED FROM MEASURED RESISTANCE AS FOLLOWS:
FOR TEMPERATURES BELOW 273.16K:Wref(T) = W(T) - a4*[W(T)-I] - b4*[W(T)-I]InW(T)
FOR TEMPERATURES AT AND ABOVE 273.16K:Wref(T) = W(T) - a8*(W(T)-I] - b8*[W(T)-I]^2
WHERE W(T) = R(T)/R(273.16K), FOR T IN KELVIN;Wref(T) DEFINES TEMPERATURE ACCORDING TO THEITS-90 REFERENCE FUNCTION (SEE FOLLOWING PAGE);AND THE COEFFICIENTS a4, b4, a8, AND b8 AREUNIQUE TO EACH INDIVIDUAL THERMOMETER.
a8 = -5.4864581D-04b8 = +1.0006569D-04a4 = -3.3185991D-04b4 = -2.9061316D-06
R(OC) = 199.904 OHMSR(100C)/R(OC) = 1.3926
MEASUREMENT DATATEMP (-C) RESISTANCE (OHMS)
-189.34 43.2079-38.83 168.768
0.010 199.912100.00 278.392231.928 378.311
MEASUREMENTS BY: D. JACOBSCERTIFIED BY: G. ENGELBRECHT
DATE CERTIFIED: 10 JUNE 1993
N.I.S.T. TEST REPORT No. 811/250375DATE OF N.I.S.T. TEST: 4 DECEMBER 1992
Attachment #3 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 7 of 32
MINCO Products, Inc. Report No. 33067300 Commerce Lane Job No. 3-254185Fridley, MN 55432 P.O.# 02140472Tel: (612) 571-3121
t FAX: (612) 571-0927
Report of Calibration*** CERTIFICATE ** *
forPlatinum Resistance Thermometer
Model XS7927PKIL76S Serial No. 1309Prepared by MINCO PRODUCTS, INC.for NORTHEAST NUCLEAR ENERGY CO.
The thermometer resistance was measured at fixed temperaturepoints defined by ITS-90 or by comparison with a calibratedPlatinum Resistance Thermometer traceable to the NationalInstitute of Standards and Technology. Resistances weremeasured with an excitation current of 1.0mA.
Temperature is derived from measured resistance as follows:
for temperatures below 273.16K:Wref(T) = W(T) - a4*[W(T)-I] - b4*[W(T)-IjlnW(T)
for temperatures at and above 273.16K:Wref(T) = W(T) - a8*[W(T)-I] - b8*[W(T)-1I]2
1 where W(T) = R(T)/R(273.16K), for T in Kelvin;Wref(T) defines temperature according to theITS-90 reference function (see following page);and the coefficients a4, b4, a8, and b8 areunique to each individual thermometer.
a8 = -4.5088398D-04b8 = +1.4870006D-04a4 = -6.0597493D-04.b4 = +3.1314950D-04
R(0 0 C) = 200.008 ohmsR(100 0 C)/R(00 C) = 1.3927
Measurement dataTemp (OC) Resistance (ohms)-189.34 43.349
-38.83 168.8660.010 200.016
100.00 278.546231.928 378.533
Measurements by: JESCertified by: M. SWENSON
Date certified: 14 July 2000
N.I.S.T. Test Report No. 14-HS876-1-1Date of N.I.S.T. test: 6 May 1999
Attachment #4 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 8 of 32
,47YA!&46Ore-~
Hart Thermometry System Accuracies
SPRT + Thermometer UncertaintiesDevice Temperature Accuracy Combined Uncertainty
1590 -200 to 6610C ±0.00150C +0.0025005681 -200to661°C ±0.0020C
Bath UncertaintiesDevice Parameter Tem erature Specification
-40°C ±0.0020C00C ±0.0010C
7037 Stability 250C ±0.00050C±10000 +0.0020C
Uniformity All ±0.0020C
Stability 1000C ±0.0030C6022 3000C ±0.0050C
6022 1000C ±0.0040CUniformity 3000C ±0.0120C
<3000C ±0.0300C9260 Stability >3000C ±0.0500C
Uniformity 50 to 6800C ±0.0200C
Fixed PointFixed Point Cell Temperature Uncertainty5901 D-Q TPW 0.010C ±0.0001 0C
5946 MP Zn 429.5270C ±0.0020C
Combined Uncertainties (Bath + 1590 + 5681)Bath Temperature Combined Uncertainty
-400C ±0.0038°C000C ±0.00340C
250C ±0.00320C
1000C ±0.00380C1000C ±0.00560C3000C ±0.01 320C
9260 <3000C ±0.03610C>3000C +0.05390C
0=>
SNancy M Nowlan (Generation - 6)
0,
From: Robert J Byrnes (Generation - 4)Sent: Thursday, August 02, 2012 3:26 PMTo: Nancy M Nowlan (Generation - 6)Subject: Accuracy of Data Generated by Metrology Laboratory RTD Calibrations
Nancy,
Measurement uncertainty for all standards used for calibration of RTDs by the Millstone Metrology Laboratory is ±0.0038*C. This excludes the uncertainty of theCallendar Van Dusen equation, which generates the Temperature vs. Resistance table and coefficients. The CVD equation, used to generate the table and
m
coefficients, contributes such an inconsequential uncertainty, that it is not worthy of consideration.The RTD data provided by Minco has an uncertainty of 0.0250 C. The calibrations performed by the Millstone Metrology Laboratory are 6.58 times more accurate.
-P
bob byrnesInstrument Tech Ill C"
Tie Line: 8.759.6229Phone: 860.447.1791 x6229 0Fax: 860.444.5317 0
Pager: 860.504.43650D
"The only stupid question is the one you don't ask." 0
ccO
Attachment #6 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 10 of 32
-Report for Callendar-Van Dusen Coefficients --,-- .
Model: XS7-927PK ISerial: 1309 t-Da~te-: August 04,2009
Rekfrence (OC)-1 9:9433
0.038025.021150,0 17675.0155
I00.0214
UUT (Ohms)184.0662199.9719219.8137239.5121259.0611278.4672
,5 5-.5 7 C) e7(3Residual (QC)
0.00000.0000
-0.00160.00030.0012
-0.0007
Coefficients:RO = 199.941595ALPHA = 0.00392657DELTA = 1.54203BETA = -9.55746
P'age Iof 3
Attachment #8 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 11 of 32
,f,VrCftAlC' ce&r
Model: XS7927PK1 Serial: 1309 Callendar-Van Dusen Temperature vs. Resistance TableOF
-4.00-3.00-2.00-1.000.001.002.003.004.005.006.007.008.009.0010.0011.0012.0013.0014.0015.0016.0017.0018,0019.0020.0021.0022.0023.0024.0025.0026.0027.0028.0029.0030.0031.0032.0033.0034.0035.0036.0037.0038.0039.0040.0041.0042.0043.0044.0045.0046.0047.0048.0049.0050.0051,0052.0063.00
Resistance184.02137184.46076184.90046185.34044185.78069186.22121186.66197187.10296187.54418187.98560188.42723188.86903189.31101189.75315190.19543190.63785191.08040191.52306191,96583192.40868192.85162193.29463193.73770194.18082194.62397195.06716195.51037195.95359196.39682196.84003197.28323197.72640198.16954198.61264199.05569199.49867199.94159200.38444200.82721201.26991201.71253202.15508202.59756203.03995203.48228203.92453204.36670204.80880205.25083205.69278206.13465206.57645207.01818207.45983207.90141208.34291208.78433209.22569
dr/dT OF0.4392383 54.000.4395457 55.000.4398394 56.000.4401196 57.000,4403863 58.000,44063991 59.00
0,4408804 60.000.44110801 61.000.4413230 62.000.4415254 63.000.4417155 64.000.4418934 65.000,4420593 66.000.4422133 67.000.4423557 68.000.4424866 69.000.4426062 70.000.4427146 71.000.4428121 72.000.4428987 73.000.44297471 74.000.4430403 75.000.4430955 76.000.4431406 77.000.44317581 78.000.4432012! 79.000.4432170f 80:000.4432233, 81.000,4432204! 82.000.44320841 83.000.44318751 84.000.44315781 85.000.44311961 86.000.4430729 87.000.4430180 88.000.4429551 89.000.4428843 90.000.4428095 91.000.4427348 92.000.4426601 93.000.4425853 94.000.4425106 95.000.4424359 96.000.44236111 97.000.4422864 98.000,44221171 99.000.44213701 100.000.4420622 101.000.4419875 102.000.4419128 103.000.4418380 104.000.4417633 105.000.4416886 106.000,44161381 107.000.4415391 108.000.44146441 109.000.44138971 110.000.4413149 111.00
Resistance209.66696210.10817210.54929210.99035211.43133211.87223212.31306212.75381213.19449213.63510214.07563214.51608214.95647215.39677215.83700216.27716216.71724217.15725217.59718218.03704218.47682218.91653219.35616219.79572220.23521220.67462221.11395221,55321221.99240222.43151222.87054223.30950223.74839224.18720224.62594225.06460225.50319225.94170226.38014226.81850227.25679227.69500228.13314228,57120229.00919229.44711229.88495230,32271230.76040231.19802231.63556232.07303232.51042232.94774233.38498233.82215234.25924234.69626
dr/dT i OF Resistance0.4412402 112.00 235.133200.44116551 113.00 235.570070.44109071 114.00 236.006860.4410160 115.00 236.443580.44094131 116.00 236.880220.44086651 117.00 237.316790.4407918 118.00 237.753290.4407171 119.00 238.189710.4406424 120.00 238.626050.4405676 121.00 239.062330,4404929 122.00 239.498520.4404182 123.00 239.934640.4403434 124.00 240.370690.4402687 125.00 240.806660.4401940 126.00 241.242560.4401192 127.00 241.678380.4400445 128.00 242.114130.4399698 129.00 242.549800.4398951 130.00 242.985400.4398203 131.00 243.420920.4397456 132.00 243.856370.4396709 133.00 244.291740.4395961 134.00 244.727040.4395214 135.00 245.162270.4394467 ; 136.00 245.597420.4393719 137.00 246.032490.4392972 138.00 246.467490.4392225 139.00 246.902420.43914781 140.00 247.337270,4390730 141.00 247.772050,4389983 142.00 248.206750,4389236 143.00 248.641370.4388488 144.00 249.075920.4387741 145.00 249.510400,4386994 146.00 249.944800.4386246 147.00 250.379130.4385499 148.00 250.813380.4384752 149.00 251.247560.4384005 150.00 251,681670.4383257 151.00 252,115700,4382510 152.00 252.549650.4381763 153.00 252,983530.4381015 154.00 253.417330.4380268 155.00 253.851060.4379521 156.00 254.284720.4378773 157.00 254,718300.4378026 158.00 255.151800.4377279 159.00 255.585240.4376532 160.00 256,018590.4375784 161.00 256,451870.4375037 162.00 256.885080.4374290 163.00 257.318210.4373542 164.00 257.751270.4372795 165.00 258.184250.4372048 166.00 258.617160.4371300 167.00 259.049990.4370553 168.00 259.482750.4369806 169,00 259.91543
drldT0.43690590.43683110,43675640.43668170.43660690.43653220.43645750.43638270.43630800.43623330.43615860.43608380.43600910,43593440,43585960.43578490.43571020.43563540.43556070.43548600.43541130.43533650.43526180.43518710.43511230.43503760.43496290.43488810.43481340.43473870.43466400.43458920,43451450.43443980.43436500.43429030.43421560,43414080,43406610.43399140.43391670.43384190.43376720.43369250.43361770,43354300.43346830.43339350.43331880.43324410.43316940.43309460.43301990.43294520.43287040.43279570.43272100.4326462
Page 2 of 3 Date: August 04,2009
Attachment #6 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 12 of 32
Model: XS7927PKI Serial: 1309 Callendar-Van Dusen Temperature vs. Resistance TableOF Resistance drldT
170.00 260.34804 0.4325715171.00 260.78058 0.4324968172.00 261.21304 0.4324221173.00 261.64542 0.4323473174.00 262.07773 0.4322726175.00 262.50997 0.4321979176.00 262.94213 0.4321231177.00 263.37421 0.4320484178.00 263.80622 0.4319737179.00 264.23816 0.4318989180.00 264.67002 0.4318242181.00 265.10181 0.4317495182.00 265.53352 0.4316748183.00 265.96516 0.4316000184.00 266.39672 0.4315253.185.00 266.82821 0.4314506*186.00 267.25962 0.4313758!
187.00 267.69096 0,4313011!188.00 268.12222 0.4312264;
189.00 268.55341 0.4311516.190.00 268,98453 0.4310769-191.00 269.41557 0.4310022:192.00 269.84653 0.4309275:193.00 270.27742 0,4308527:194.00 270,70824 0.4307780195.00 271.13898 0.4307033,196.00 271.56964 0.4306285197.00 272.00023 0.4305538198.00 272.43075 0.4304791199.00 272.86119 0.4304044200.00 273.29156 0.4303296201.00 273.72185 0.4302549202.00 274.15207 0.4301802203.00 274.58221 0.4301054204.00 275.01228 0.4300307205.00 275.44227 0.4299560206.00 275.87219 0.4298812207.00 276.30204 0.4298065208.00 276.73181 0.4297318209.00 277.16150 0.4296571210.00 277.59112 0.4295823211.00 278.02066 0.4295076212.00 278.45014 0.4294329
Page 3 of 3 Date: August 04,2009
Attachment #6 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 13 of 32
,rA(#C e A17- Et
Report No: RU200908073-001Page 1 of 3
Report of Calibration
DominionRope Ferry Road
Bldg 433, Metrology LaboratoryWaterford, CT 06385
Model: XS7927PK1 Customer: DominionSerial: 1270 ' , 1'o Rope Ferry Road
Description: RTD PLANT INSTALLED Bldg 433, Metrology LaboratoryWaterford, CT 06385
Calibration Range: LimitedReceived Condition: Recalibration
Current: 1.0 mAProcedure: MTE 1142E
Actual Value(Reference)
(C)
-19.926700.04100
25.0249050.0159075.01290
100.01760
UUT(Test Sensor)
(Ohms)
183.96920199.93170219.76970239.46400259.01160278.41470
Residuals(C)
0.00000.00000.0005
-0.0003-0.00010.0001
Method ofRealization
COMPCOMPCOMPCOMPCOMPCOMP
'Callendar-Van Dusen Coefficients:
RO = 199.89901ALPHA= 0.00392709
DELTA= 1.53452BETA = -0.12847
Test Equipment
Manufacturer Model Description Serial Number Recall Date
Hart Scientific 1590 Super Thermometer I1 A68350 09/03/2009Hart Scientific 5681 SPRT, 25 ohm 1466 02/25/2010Hart Scientific 7037 Bath, Deep Low-Temp 93046 NCR
Notes: Initial calibration to establish baseline data.
Acceptance Criteria: RO = 199,8000 to 200.2000 ohms
Prerequisitesp/et: Initial: Usage Review Required: Yes __
CR#: 111 - 'inaf Calibration Acceptable: Yes %_ No__
Technician: -17Calibration Date:Recall Date:
Temperature:Humidity:
Customer Order:
08/17/200908/12/202973.OF45%N/A
R61~rerI3 Byrne~:
Approved By: -
This report shahl not be reproduced except in full without written approval ofDondnion.
Attachment #6 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 14 of 32
A(f1~416-A'r &
08/18/2009 Temperature vs.'-% tance Table Repoi .o : RJ200908073.
F0.001.002.003.004.005.006.007.008.009.0010.0011.0012.0013.0014.0015.0016.0017.0018.0019.0020.0021.0022.0023.0024.0025.0026.0027.0028.0029.0030.0031.0032.0033.0034,0035,0036.0037.0038.0039.0040.0041.0042.0043.0044.0045.0046.0047.0048.0049.0050.0051.0052.0053.0054.0055.00
" 56.0057.0058.00
Resistance185.69151186.13661186.58163187.02658187.47147187.91628188.36102188.80570189.25030189.69482190.13928190,58367191.02798191.47223191.91640192.36050192.80452193.24848193.69236194.13617194.57990195.02357195.46716195,91067196.35412196,79749197.24078197.68401198.12715198.57023199.01323199.45616199.89901200.34179200.78449201.22712201.66968202,11216202.55456202.99690203.43915203.88134204.32345204.76548205,20744205,64933206.09114206.53288206.97454207.41613207.85764208.29908208.74045209.18174209.62295210.06410210.50516210.94616211.38708
dr/dT0.44512920.44505930.44498910.44491880.44484840.44477770.44470690.44463600.44456480.44449360.44442210.44435050.44427880.44420690,44413480.44406260.44399030.44391780.44384520.44377250.44369960.44362660.44355340.44348020.44340680.44333320.44325960,44318590.44311200.44303800.44296390.44288970.44281540.44274100.44266670.44259230.44251800.44244360.44236920.44229490.44222050.44214620.44207180.44199740.44192310.44184870.44177440.44170000.44162560.44155130,44147690.44140260.44132820.44125380.44117950.44110510.44103080.44095640.4408820
666666.6'6676•7.717E7717576777879808t82,83
F59.000.001.002.003.004.005.006.007.008.009.000.001.002.003.004.005.006.007.008.00).000.00t.002.003.00
84.0085.0086.0087.0088.0089.0090.0091.0092.0093.0094.0095.0096.0097.0098.0099.00100.00101.00102.00103.00104.00105.00106.00107.00108.00109.00110.00111.00112.00113.00114.00115.00116.00117.00
Resistance211.82792212.26869212.70939213.15001213.59056214.03103214.47143214.91175215.35200215.79218216.23228216.67231217.11226217.55214217.99194218.43167218.87133219.31091219.75041220.18985220.62920221.06849221,50770221.94683222.38589222.82488223.26379223.70262224.14139224.58008225.01869225.45723225.89569226.33409226.77240227.21064227.64881228.08691228.52493228.96287229.40074229.83854230.27626230.71391231.15148231.58898232.02640232.46375232.90103233.33823233.77536234.21241234.64939235.08629235.52312235.95987236.39656236.83316237.26969
dr/dT0.44080770.44073330.44065900.44058460.44051020.44043590.44036150.44028720.44021280.44013840.44006410.43998970.43991540.43984100.43976660.43969230.43961790.43954360.43946920.43939480.40932050.43924610.43917180,43909740.43902300.43894870.43887430.43880000,43872560.43865120.43857690.43850250.43842820.43835380.43827940.43820510.43813070.43805640.43798200.43790760.43783330.43775890.43768460.43761020.43753580.43746150.43738710.43731280.43723840,43716400.43708970.43701530.43694100.43686660.43679220.43671790.43664350.43656920.4364948
139.00140.00141.00142.00143.00144.00145.00146.00147.00148.00149.00150.00151.00152.00153.00154.00155.00156.00157.00158.00159.00160.00161.00162.00163.00164.00165.00166.00167.00168.00169.00170.00171.00172.00173.00174.00175.00176.00
F118.00
119.00120.00121.00122.00123.00124.00125.00126.00127.00128.00129.00130.00131.00132.00133,00134.00135.00136.00137.00138.00
Resistance237.70615238.14253238.57884239.01508239.45124239.88732240.32334240.75927241.19514241.63092242.06664242.50228242.93784243.37333243.80875244.24409244.67936245.11455245.54967245.98472246.41969246.85458247.28941247.72415248,15883248,59342249.02795249.46240249.89677250.33108250.76530251.19945251.63353252.06754252.50147252.93532253.36910253.80281254.23644254.67000255.10348255.53689255.97022256.40348256.83667257.26978257.70282258.13578258.56867259.00148259.43422259.86689260.29948260.73200261.16444261.59681262.02910262.46132262.89346
-001 Page2of3
dr/dT0.43642040.43634610.43627170.43619740.43612300.43604860.43597430.43589990.43582560.43575120.43567680.43560250.43552810.43545380.43537940.43530500.43523070.43515630.43508200.43500760.43493320.43485890.43478450.43471020.43463580.43456140.43448710.43441270.43433840.43426400.43418960.43411530.43404090.43396660.43389220.43381780.43374350.43366910.43359480.43352040.43344600.43337170.43329730.43322300.43314860.43307420.43299990.43292550.43285120.43277680.43270240.43262810.43255370.4324794
0.43240500.43233060.43225630.43218190.4321076
Attachment #6 ETE-MP-2012-1135 Report Generated on 816/2012 3:06:09 PM
.,, 70CHW1 SPage 15 of 32
08/18/2009 Temperature vs. RL ,tance Table
F Resistance dr/dT177.00 263.32553 0.4320332178.00 263.75753 0,4319588179.00 264.18945 0.4318845180.00 264.62130 0.4318101181.00 265.05307 0.4317358182.00 265.48477 0.4316614183.00 265.91639 0.4315870184.00 266.34794 0.4315127185.00 266.77942 0.4314383186.00 267.21082 0.4313640187.00 267.64215 0.4312896188.00 268.07340 0.4312152189.00 268.50458 0.4311409190.00 268.93568 0.4310665191.00 269.36671 0.4309922192.00 269.79767 0.4309178193.00 270.22855 0.4308434194.00 270.65935 0.4307691195.00 271.09008 0.4306947196.00 271.52074 0.4306204197.00 271.95133 0.4305460198.00 272.38183 0.4304716199.00 272.81227 0.4303973200.00 273.24263 0.4303229201.00 273.67291 0.4302486202.00 274.10313 0.4301742203.00 274.53326 0.4300998204.00 274.96333 0.4300255205.00 275.39331 0.4299511206.00 275.82323 0.4298768207.00 276.25307 0.4298024208.00 276.68283 0.4297280209.00 277.11252 0.4296537210.00 277.54214 0.4295793211.00 277.97168 0.4295050212.00 278.40115 0.4294306
R.9 0-/1" Pag * of5 Z--Re poi, . o: RJ200908073-001 Page 3 of 3
Attachment #6 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 16 of 32
ff,4 c:/ Ito a//"o
Report No: RJ200908072-001Page 1 of 3
Report of Calibration
Dominion Nuclear ConnecticutRope Fenry Road
Bldg 433, Metrology LaboratoryWaterford, CT 06385
-31n.,OD-2 76~3aModel: XS7927PK1 Customer: Dominion Nuclear ConnecticutSerial: 1269 6• 730 Rope Ferry Road
Description: RTD PLANT INSTALLED Bldg 433, Metrology LaboratoryWaterford, CT 06385
Calibration Range: LimitedReceived Condition: New
Current: 1.0 mAProcedure: MTE 1142E
Actual Value(Reference)
(C)
-19.926700.04100
25.0248050.0174075.01330
100.01830
UUT(Test Sensor)
(Ohms)
183.91050199.86790219.69950239.38870258.92880278.32550
Residuals(C)
0.00000.00000.0006
-0.00040.00000.0001
Method ofRealization
COMPCOMPCOMPCOMPCOMPCOMP
Callendar-Van Dusen Coefficients:
RO = 199.83522ALPHA = 0,00392705
DELTA'= 1.53631BETA = -0.14945
Test Equipment
Manufacturer Model Description Serial Number Recall Date
Hart Scientific 1590 Super Thermometer II A68350 09/03/2009Hart Scientific 5681 SPRT 1466 02/25/2010Hart Scientific 7037 Bath, Deep Low-Temp 93046 NCR
Notes: Initial calibration to establish baseline data.
Acceptance Criteria: RO = 19 9.8 p 200.2 ohms
Prerequisites rpet: Initial: Usage Review Required: YesCR#: Pinal'Cahbration Acceptable: Yes/x_. No _
Calibration Date:Recall Date:
Temperature:Humidity:
Customer Order:
08/06/200908/01/202973.OF38%53M20707631
Technician:
Approved By:
This report shall not be reproduced except in.fidl without written approval of Dominion Nuclear Connecticut.
Attachment #6 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 17 of 32
1.-rg.C/Y1IhW7- o'
08/07/2009 Temperature vs. Resihance Table Report ,: RJ200908072-001 Page Z of 3
F0.001.002.003.004.005.006.007.008.009.0010.0011.0012.0013.0014.0015.0016.0017.0018.0019.0020.0021.0022.0023.0024.0025.0026.0027.0028.0029.0030.0031.0032.0033.0034.0035.0036.0037.0038.0039.0040.0041.0042.0043.0044.0045.0046.0047.0048.0049.0050.0051.0052.0053.0054.0055.0056.0057.0058.00
Resistance drldT185.63222 0.4449825186.07716 0.4449132186.52204 0.4448437186.96685 0.4447740187.41159 0.4447041187.85626 0.4446340188.30086 0.4445637188.74539 0.4444932189,18984 0.4444226189.63423 0.4443517190.07855 0.4442807190.52279 0.4442095190.96697 0.4441381191.41107 0.4440666191.85510 0.4439948192.29906 0.4439229192.74295 0.4438509193.18676 0.4437786193.63050 0.4437062194.07417 0.4436337194.51777 0.4435610194.96129 0.4434881195.40475 0.4434151195.84812 0.4433420196.29143 0.4432687196.73466 0.4431952197.17782 0.4431216197.62091 0.4430479.198.06392 0.4429741198.50685 0,4429001198.94972 0.4428260199.39251 0.4427517199.83522 0.4426774200.27786 0,4426030200.72043 0.4425285201.16292 0.4424541201.60533 0.4423797202.04768 0.4423053202.48994 0.4422309202.93214 0.4421564203.37426 0.4420820203.81630 0.4420076204.25827 0.4419332204.70017 0.4418587205.14199 0.4417843205.58374 0.4417099206.02541 0.4416355206.46701 0.4415611206.90853 0.4414866207.34998 0.4414122207.79136 0.4413378208.23266 0.4412634208.67388 0.4411889209,11503 0.4411145209.55611 0.4410401209.99712 0.4409657210.43804 0.4408913210.87890 0.4408168211.31968 0.4407424
F Resistance drldT59.00
60.0061.0062.0063.0064.0065.0066.0067.0068.0069.0070.0071.0072.0073.0074.0075.0076.6077.0078.0079.0080.0081.0082.0083.0084.0085.0086.0087.0088.0089.0090.0091.0092.0093.0094.0095.0096.0097.0098.0099.00100.00101.00102.00103.00104.00105.00106.00107.00108.00109.00110.00111.00112.00113.00114.00115.00116.00117.00
211.76038 0.4406680212.20101 0,4405936212.64157 0.4405191213.08205 0.4404447213.52246 0.4403703213.96279 0.4402959214.40305 0.4402215214.84324 0.4401470215.28334 0.4400726215.72338 0.4399982216.16334 0.4399238216.60323 0.4398493217.04304 0.4397749217.48278 0.4397005217.92244 0.4396261218.36203 0.4395517218.80154 0.4394772219'.24098 0,4394028219.68035 0.4393284220.11964 0.4392540220.55886 0.4391795220.99800 0.4391051221.43707 0.4390307221.87606 0,4389563222.31498 0.4388819222,75383 0.4388074223.19260 0.4387330223,63129 0.4386586224.06991 0.4385842224.50846 0.4385097224.94693 0.4384353225.38533 0,4383609225.82365 0.4382865226.26190 0.4382121226.70008 0.4381376227.13818 0.4380632227.57620 0,4379888228.01416 0.4379144228.45203 0.4378399228.88984 0.4377655229.32756 0.4376911229,76522 0.4376167230,20280 0.4375423230.64030 0.4374678231.07773 0.4373934231.51509 0.4373190231.95237 0.4372446232.38958 0.4371701232.82671 0.4370957233.26377 0.4370213233.70075 0.4369469234.13766 0.4368725234.57450 0.4367980235.01126 0,4367236235.44795 0.4366492235.88456 0.4365748236.32110 0.4365003236.75756 0.4364259237.19395 0.4363515
F Resistance drldT118.00 237.63026 0.4362771
119.00 238.06650 0.4362027120.00 238.50267 0.4361282121.00 238.93876 0.4360538122.00 239.37477 0.4359794123.00 239.81072 0.4359050124.00 240.24658 0.4358305125.00 240,68238 0.4357561126.00 241.11810 0.4356817127.00 241.55374 0.4356073128.00 241.98931 0.4355329129.00 242.42481 0.4354584130.00 242.86023 0.4353840131.00 243.29558 0.4353096132.00 243.73085 0.4352352133.00 244.16605 0.4351607134.00 244.60117 0.4350863135.00 245,03622 0.4350119136.00 245.47119 0.4349375137.00 245.90609 0.4348631138.00 246.34092 0.4347886139.00 246.77567 0.4347142140.00 247.21035 0.4346398141.00 247.64495 0.4345654142.00 248.07948 0.4344909143.00 248.51393 0.4344165144.00 248.94831 0.4343421145.00 249.38262 0.4342677146.00 249.81685 0.4341933147.00 250.25100 0.4341188148.00 *250.68508 0.4340444149.00 251.11909 0.4339700150.00 251.55302 0.4338956151.00 251.98688 0.4338211152.00 252.42067 0.4337467153.00 252.85438 0.4336723154.00 253.28801 0.4335979155.00 253.72157 0.4335235156.00 254.15506 0.4334490157.00 254.58847 0.4333746158.00 255.02181 0.4333002159.00 255.45507 0.4332258160.00 255.88826 0.4331513161.00 256.32137 0.4330769162.00 256.75441 0.4330025163.00 257.18738 0.4329281164.00 257.62027 0.4328537165.00 258.05309 0.4327792166.00 258.48583 0.4327048167.00 258.91849 0.4326304168.00 259.35109 0.4325560169.00 259.78361 0.4324815170.00 260.21605 0.4324071171.00 260.64842 0.4323327172.00 261.08072 0.4322583173.00 261.51294 0.4321839174.00 261.94508 0.4321094175.00 262.37716 0.4320350176.00 262.80915 0.4319606
Attachment #6 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM
4 m7- ePage 18 of 32
08/07/2009 Temperature vs. Resx-tance Table.F Resistance drldT
177.00 263.24108 0.4318862178.00 263.67293 0.4318117179.00 264.10470 0.4317373180.00 264.53640 0.4316629181.00 264.96803 0.4315885182.00 265.39958 0.4315141183.00 265.83106 0.4314396184.00 266.26246 0.4313652185.00 266.69379 0.4312908186.00 267.12504 0.4312164187.00 267.55622 0.4311419188.00 267.98732 0.4310675189.00 268.41835 0.4309931190.00 268.84931 0.4309187191.00 269.28019 0.4308443192.00 269.71100 0.4307698193.00 270.14173 0.4306954194.00 270.57239 0.4306210195.00 271.00297 0.4305466196.00 271.43348 0.4304721197.00 271.86392 0.4303977198.00 272.29428 0.4303233199.00 272.72456 0.4302489200.00 273.15477 0.4301745201.00 273.58491 0,4301000202.00 274.01498 0.4300256203.00 274.44496 0.4299512204.00 274.87488 0.4298768205.00 275.30472 0.4298023206.00 275.73448 0.4297279207.00 276.16417 0.4296535208.00 276.59379 0.4295791209.00 277.02333 0.4295047210.00 277.45280 0.4294302211.00 277.88219 0.4293558212.00 278.31151 0.4292814
Report j: RJ200908072-001 Page 3 of 3
Attachment #7 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 19 of 32
Sensor Calculator - Resistance table generator 9,'f'466Il /9 6 Page 1 of 1
PJ c~ R WE Search
MINCO Home Products Applications Resources About Us
Table Options Select Element Start Over Interchangeability Quick Calc Gen
Temperature Vs. ResistancePLATINUM: PIA TCR = 3.93e-3
Ro = 199.872
A4 =-0.00036445181 B4 =-2.8576799E-06 A8 =-0.00040758054 B8 = 8.3733738E-05
Values are in OhmsTemp +0 +1 +2 +3 +4 +5 +6 +7 +8 +9
-F0 185.6584186.1035186.548 186.9934187.4383187.8831 188.3278188.772 189.2170189.661.10 190.1059 190.5502190.9945 191.4387 191.882 192.3268192.7708193.2147 193.658 194.10220 194.5459 194.9895195.4330 195.8765 196.3198196.7631197.2063 197.6495 198.092 198.535530 198.9784.199.4213199.8640 200.3067 200.7493 201.1918 201.6343 202.0766 202.5189 202.961140 203.40331203.8454 204.2873 204.72931205.1711 205.612 206.0546206.496 206.9377 207.379250 207.82061208.2619 208.703 209.14431209.585 210.0265 210.467 210.908 211.3491211.789860 212.230 212.6710213.1115213.5520213.9923214.4326214.8728215.312 215.7530216.192970 216.63281217.0727 217.5124 217.9521 218.3917 218.8312219.2707 219.7101 220.1494 220.588680 -1221.02781221.46681221.905 222.3448222.7837223.222 223.6611224.0998224.5383224.9768
1.90 1225.41521225.8536 226.291 _226.7300 227.1681227.6062 228.0442228.4821 228.919 229.3576
Temp +0 +1 +2 +3 +4 +6 +9
100 229.7953 1 1 1
© 2011 Minco, All Rights Reserved Flexible Heaters I Flex Circuits J Sensors I Instruments I Careers I Privacy Policy I
http://www.minco.com/tools/sensorcalc/rtd/display.aspx?action=options 08/06/2012
Attachment #7 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 20 of 32
19 1-M1/14ý0i &A17 e
p4wr&z i 01,3--
TEMP F
0
510
15
20
25
30
35
40
45
5055
6065
70
758085
9095
100
ITS-90R (ohms)185.6584
187.8831
190.1059
192.3268
194.5459
196.7631
198.9784
201.1918
203.4033
205.6129
207.8206
210.0265
212.2305
214.4326
216.6328
218.8312
221.0278
223.2224
225.4152
227.6062
229.7953
Met LabR (ohms)
185.63222187.85626190.07855192.29906194.51777196.73466198.94972201.16292203.37426205.58374207.79136209.99712212.20101214.40305216.60323218.80154
220.998223.1926225.38533227.5762229.76522
Serial # 1269
Error(ohms)
0.02618
0.02684
0.02735
0.027740.02813
0.02844
0.02868
0.02888
0.02904
0.02916
0.02924
0.02938
0.02949
0.02955
0.02957
0.02966
0.0298
0.0298
0.02987
0.03
0.03008
Error% Reading
0.01410.01430.01440.01440.01450.01450.01440.01440.01430.01420.01410.01400.01390.01380.01360.01360.01350.01330.01330.01320.0131
Error% Span
0.032
0.032
0.033
0.0330.033
0.033
0.033
0.033
0.032
0.032
0.032
0.032
0.031
0.031
0.031
0.031
0.031
0.030
0.030
0.030
0.030
span 44.1369
Certified by Minco in 1993Met Lab Cal performed in 200916 years between Minco and Met Lab Reports
repeatability Drift
0.01% .05deg C/yr
16 year drift RSS drift & repeatability
0.36 0.3604
3
Serial # 1269 ITS-90 VS MET LAB
230 -
225 -
miq
220
-a
IZ 215E
210 0C 0D
-ITS TOCaliData0205 -M LAB Cal Data C
200
195
190 .•
0 10 20 30 40 50 60 70 80 90 100
Temperature (Deg F)
CD
0
(-3N)
3
Serial # 1269 ITS-90 VS MET LAB
0)
.220
219.8
219.6
219.4
219.2
219
218.8
218.6
218.4
218.2
218
•~ITS9!0 Cal Data
-M LAB Cal Data
m--A
CA,
0CD
0
P.
(C,
74 74.2 74.4 74.6 74.8 75
Temperature (Deg F)
75.2 75.4 75.6 75.8 76
QI-V
CDto0(0w
N3
Attachment #7 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 23 of 32
,,# jrf9-6'41&A/F fSensor Calculator - Resistance table generator
Sý,.,r CNO\ 1-L-)
Page 1 of 1
Search I
IfMINCO Home Products Applications i Resources i About Us
Table Options Select Element Start Over Interchangeability Quick Calc Gen.
Temperature Vs. ResistancePLATINUM: PIA TCR = 3.93e-3
R0 = 199.904
A4 = -0.00033185991 B4 = -2.9061316E-06 A8 = -0.00054864581 B8 = 0.00010006569
Values are in OhmsTemp +0 +1 +2 +3 +4 +5 +6 +7 +8 +9
oF I0 185.6876186.132 186,577 187,0229187.4679187.9128188.3576188.8023189.2469189.691510 190.1360190.5804 191.0248191.4691 191.9133192.3574 192.8014 193.2454193.6893194.133120 194.576 195.020 195.4642195.9077196.3511196.7945197.237 197.6810198.1242 198.567330 199.0103199.453 199,8960200.3387 200.7813201.2238201.6663202.1087202.5510202.993240 203.4354 203.8774 204.3194 204.7614205.2032205.6450206.086 206.5283 206.9699207.411450 207.8528 208.2941 208.735 4209.1765 209.6176210.0587 210.4996(210.9405211.3813211.822060 212.2627 212.7033 213.1438213.5842214.0246214.4649214,9051215.3452215.7853216.225370 216.6652217.105 217.5448217.9845 218.4241218.863 219.30311219.7425220.1818220.621080 221.060 221.4993,221.9383 222.3773222.8161223.2549223.6936 224.1323 224.5709 225.009490 225.4478 225,8861 •226.3244 226.7626 227.2007 227.63881228.0768 228.5141228.9525 229.3903
Temp +0 +I1 +2 +3 +4 +5 +6 +7 +8 +9Fo
100 1229.8279
© 2011 Minco, All Rights Reserved Flexible Heaters I Flex Circuits I Sensors I Instruments I Careers I Privacy Policy I
http://www.niinco.com/tools/sensorcalc/rtd/display.aspx?action=options 08/06/2012
Attachment #7 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM -Page 24 of 32
TEMP F
0
5
1015
20
25
30
35
40
45
50
55
6065
7075
80
85
90
95
100
ITS-90
R (ohms)185.6876
187.9128
190.1360
192.3574
194.5769
196.7945
199.0103
201.2238
203.4354
205.6450
207.8528
210.0587
212.2627
214.4649
216.6652
218.8636
221.0602
223.2549
225.4478
227.6388
229.8279
Met LabR (ohms)
185.69151187.91628190.13928192.36050194.57990196.79749199.01323201.22712203.43915205.64933207.85764210.06410212.26869214.47143216.67231218.87133221.06849223.26379225.45723227.64881229.83854
Serial # 1270
Error(ohms)
-0.00391
-0.00348
-0.00328
-0.0031
-0.003
-0.00299
-0.00293
-0.00332
-0.00375
-0.00433
-0.00484-0.0054
-0.00599
-0.00653
-0.00711
-0.00773
-0.00829
-0.00889
-0.00943
-0.01001
-0.01064
Error
% Reading
-0.0021
-0.0019
-0.0017
-0.0016
-0.0015
-0.0015
-0.0015
-0.0016
-0.0018
-0.0021
-0.0023
-0.0026
-0.0028
-0.0030
-0.0033
-0.0035
-0.0038
-0.0040
-0.0042
-0.0044
-0.0046
Error
% Span
-0.005
-0.004
-0.004
-0.004
-0.003
-0.003
-0.003
-0.004
-0.004
-0.005
-0.005
-0.006
-0.006
-0.007
-0.007
-0.008
-0.008
-0.009
-0.009
-0.010
-0.010
span 44.1403
Certified by Minco in 1993
Met Lab Cal performed in 2009
16 years between Minco and Met Lab Reports
repeatability Drift
0.01% .05deg C/yr
16 year drift RSS drift & repeatability
0.36 0.3604
C)
CD
Serial # 1270 ITS-90 VS MET LAB
230.0000
225.0000
220.0000
-. 215.0000E
210.0000
205.0000
200.0000
195.0000
190.0000
185.0000
- ITS O Cal Data
M ETLAB Cal Data
M-i
CD
C)C)CD
0:3
0
0)
N
0 10 20 30 40 50
Temperature (Deg F)
60 70 80 90 100
IDC)
0C.)
N)
Serial # 1270 ITS-90 VS MET LAB0
0
0a,U
(0
a)
220.0000
219.8000
219.6000
219.4000
219.2000
219.0000
218.8000
218.6000
218.4000
218.2000
218.0000
Serial # 1270 ITS-90 VS MET LAB
• '- ITS! 10 Cal Data
so- METLAB Cal Data
m-Im
-uN,0
N,
C71
0
0
00
0
00.0
co
N,0
N,
Co00)6CD
*4,
74 74.2 74.4 74.6 74.8 75
Temperature (Deg F)
75.2 75.4 75.6 75.8 76
(D
0
CoN,
Attachment #7 ETE-MP-2012-1135 Report Generated on 816/2012 3:06:09 PM Page 27 of 32
Sensor Calculator - Resistance table generator Page 1 of 1/'A166 2 -10--,3Zý
Faý Search~
MINCO Home Products I Applications Resources 1 About Us C
Table Options Select Element Start Over Interchangeability Quick Calc Genej
Temperature Vs. ResistancePLATINUM, PIA TCR = 3.93e-3
Ro = 200.008
A4 =-0.00060597493 B4 = 0.0003131495 AB =-0.00045088398 Ba =0.00014870006
Values are in Ohmsemp +0 +1 +2 +3 +4 +5 +6 +7 +8 +90F •_
0 185.7885186.2337186.6789 187.1241187.5691188.0141188.4590188.9038189.3485189.793210 190.2378190.6823191.1267191.5711192.015 192.459 192.9038193.3478193.7918194.235820 194.6796195.1234195.5671196.0107 196.4543 196.8978 197.3412 197.7845 198.2277 198.670930 199.1140,199.55711200.0000 200.4430.200.8859 201.3287.201.7714 202.2140 202.6566 203.099140 203.5415 203.9839 204.42621204.8684 205.3105 205.7526 206.1945 206.6364 207.0783 207.520050 207.9617 208.40331208.8448 209.28631209.7277 210.1690 210.610 211.0514 211.4924 211.933460 212.3744 212.8152 213.2560213.6967 214.1374 214.5779 215.0184 215.4588 215.8992 216.33970 216.7796217.2197 217.65981218.0997 218.5396 218.9794 219.4192219.8588220.298 220.73780 221.177 221.6168 222.05611222.49532 22.9344 223.3735 223.8125 224.2514 224.6903 225.12990 225.5677 226.0064 226.444 226.8834 227.3218 227.7601 228.198 228.6366 229.0747 229.512
Temp +0 +1 +2 +3 +4 +5 +6 +7 +8 +9
100 1 229.9507 +1 1 171
@ 2011 Minco, All Rights Reserved Flexible Heaters I Flex Circuits I Sensors I Instruments I Careers I Privacy Policy J Sit
http://www.minco.com/tools/sensorcalc/rtd/display.aspx?action-options 08/06/2012
Attachment #7 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 28 of 32
J9 6Z8 ot 31.
Serial # 1309
ITS-90 Met Lab Error Error
TEMP F R (ohms) R (ohms) Error(ohms) % Reading % Span
0 185.7885 185.78069 0.00781 0.0042 0.010
5 188.0141 187.98560 0.0285 0.0152 0.034
10 190.2378 190.19543 0.04237 0.0223 0.050
15 192.4596 192.40868 0.05092 0.0265 0.060
20 194.6796 194.62397 0.05563 0.0286 0.065
25 196.8978 196.84003 0.05777 0.0293 0.066
30 199.1140 199.05569 0.05831 0.0293 0.06635 201.3287 201.26991 0.05879 0.0292 0.066
40 203.5415 203.48228 0.05922 0.0291 0.066
45 205.7526 205.69278 0.05982 0.0291 0.066
50 207.9617 207.90141 0.06029 0.0290 0.066
55 210.1690 210.10817 0.06083 0.0289 0.066
60 212.3744 212.31306 0.06134 0.0289 0.065
65 214.5779 214.51608 0.06182 0.0288 0.065
70 216.7796 216.71724 0.06236 0.0288 0.06575 218.9794 218.91653 0.06287 0.0287 0.065
80 221.1774 221.11395 0.06345 0.0287 0.065
85 223.3735 223.30950 0.064 0.0287 0.065
90 225.5677 225.50319 0.06451 0.0286 0.065
95 227.7601 227.69500 0.0651 0.0286 0.065100 229.9507 229.88495 0.06575 0.0286 0.065
span 44.1622
Certified by Minco in 2000
Met Lab Cal performed in 200916 years between Minco and Met Lab Reports
repeatability Drift 9 year drift RSS drift & repeatability
0.01% .05deg C/yr 0.27 0.2706
0
:7
230.0000
225.0000
220.0000
215.0000E
0
210.0000
cz 205.0000
200.0000
195.0000
190.0000
185-0000
Serial # 1309 ITS-90 VS MET LAB
-ITS 0 Cal Data
=ME" LAB Cal Data
CD-t
,m
0G)Co
MCD
0
0C.0L
0 10 20 .30 40 50
Temperature (Deg F)
60 70 80 90 100
"0(0
0
0
3
Serial # 1309 ITS-90 VS MET LAB
220.0000
219.8000
219.6000
219.4000
2.o 219.2000U
S219.0000
218.8000
218.6000
218.4000
- MT "0 Cal Data
________ ~~~~~~~ ~ ~ IVE _________ ________ ____~~LAB CalI Data
0
0b
0
C-5)
A
218.2000
218.0000 -1- I + I +
74 74.2 74.4 74.6 74.8 75 75.2 75.4 75.6 75.8 76
Temperature (Deg F)
(.0
0
0
CDNancy M Nowlan (Generation - 6)
From: Anderson, Tereasa [[email protected]]Sent: Monday, July 30, 2012 6:25 PMTo: Gus J Filippides (Generation - 6)Cc: Nancy M Nowlan (Generation - 6)Subject: Calibrated info reference REQ acc rating to old PO# 932995, Gus from DOM!Attachments: TS102(N)_L-6.pdf; S7927.pdf
Gus,I just now got it from engineering."Somewhere, I seem to have missed the original request for a 0.025°C accuracy guarantee. I have attached an old catalog page that describes the different _•
mcalibration tables, and their associated accuracy. Please note that their probe model (57927) is not listed in this table (it had already been discontinued whenT
the catalog was published). However, calibration table RT01 is listed as being accurate to +/-0.025°C. I have also attached the S7927 specification drawingthat provides repeatability and stability for this model.
You may notice that the model number listed on the calibration certs is "XS7927PK ". The "X" prefix designates an alteration of some sort from the standard-- :;0
design. In this case, "X" stands for a 200-ohm platinum element. That does not affect table calibration accuracy, nor repeatability, nor stability."
CDThank you!
Tereasa Anderson I Customer Service Representative I Minco ProductsTel: 763.586.2920 I Fax: 763-571-0927 [email protected] 07300 Commerce Lane I Minneapolis, MN 55432
wwW .rn nc0, cornco
From: Gus J Filippides [mailto:[email protected]]Sent: Monday, July 30, 2012 10:28 AMTo: Anderson, TereasaCc: Nancy M NowlanSubject: FW: Calibrated info reference to old PO# 932995, Gus from DOM!
Hello Tereasa,Did you get a response to my follow up question that I sent last week. The calibration reports do not cite any acceptance criteria for the RTDs, ie 0.025 degrees F
uncertainty.What is the accuracy of the RTDs in question that were supplied to us?
CD
1 0C.,
Attachment #8 ETE-MP-2012-1135 Report Generated on 8/6/2012 3:06:09 PM Page 32 of 32
Ref&nc~1Thiiriieters
CalibrationMinco's fully equipped standards labcan calibrate and furnish Individualtables for any thermometer in thisbulletin. All temperatures are basedon ITS-90. There are two types ofcalibration:
Fixed point calibrations
furnishes the actual fixed point val-ues and the resulting coefficients.
Comparison calibrationsUsed for oil filled thermometers,comparison calibrations match thethermometer to be measured againstan NIST traceable standard, ratherthan fixed points.
Absolute vs ratio tables
reads 1.77328 at 2001C. A ratio likethis tends to remain more stable overtime than an absolute resistance.You can periodically recheck Rooc inan ice bath and use the latest valuefor ratio calculation.
RTD calculations
These calibrations use measurementstaken at points derived from physicalconstants, such as the triple point ofwater or the freezing point of tin.The observed values are used to cal-culate coefficients for the interpolat-ing equations of ITS-90. In additionto the comniete R vs T table. Minco
Tables may list either absolute resis-tance values (RT vs T) or resistanceratios (R-t/Ro vs T) indexed to 1. Forexample, if the absolute values of athermometer are 177.47 Q at 200 0Cand 100.08 9 at 01C, the ratio table
Minco offers two options to createand print RTD tables. You candownload the DOS PC program"RTD Cailc" for use on your com-puter. We also offer "SensorCalc", anon-line tool for creating, printing andsaving RTD tables. Both are availableat www mincn.com/support.
Thermometer model (accuracy specifications may vary for other models)
S9688-S9691 S7924,S7928 $7929 S9762 S1059 S7932-S7933 S79253
Type of calibration Fixed point Fixed point Fixed point Fixed point Comparison Fixed point
-189 to -189to -189 to -269 to -189 to -189 toTemperature range 500oM 500OC 660o0 260°0 2600C -100 to 25000 64000
Ordering number for tables
RT vs T, 10C Increments RT05 RT05 RT16 RT01 RT09 RT12
ir/R0 vs T, 10C Increments RT06 RT06 RT17 RT02 RTlO RT13
RT vs T, O.10C Increments RT07 RT18 RT11 1 RT03 RT14
Rr/Ro vs T, 0.1 *C Increments RT08 RT19 RT04 RTI5
Table accuracy ±0.0250C ±0,02500 ±0.0250C ±0.025 ±0.0250C ±0.03500 ±0.0250C
Data points supplied-268.95*C (4.2K): BP helium*
-189.340C : TP of argon2
-50"C, -25°C, 175"*3
-38.830C : TP of mercury2 __•_•
0.01°C :Triple Point of water .
100'C: BP water2 _ _ _
231.928°C : FP tin .....
419.5270C: FP zinc
660.323°C : FP aluminum (+0.05-0)1 Cryogenic calibrations available on special order. 2 Comparison calibration measurement.
3 S7924, S7925 calibrations based on IEC 751, not ITS-90
The Minco strain-free elementMinco precision thermometers rely on a unique element de-sign for superior precision. It consists of a helical coil of plati-num wire, spiraled onto a grooved ceramic bobbin. This con-struction gives more support to the coils than "birdcage"designs, but does not stress the element during thermal ex-pansion. The result is stable and repeatable measurementsunder a variety of conditions.
Page L-6 Mmcv Sales: 1-763-571-3121 Fax: 1-763-571-0927 Web: www.minoo.com Bulletin TS-102Page L-6 Minco Sales: 1-763-571-3121 Fax. 1-763-571-0927 Web: www.minco.com Bulletin TS-102