17
Cafe Shay Townson Maddie Porter

Cafe Shay Townson Maddie Porter. Table of Contents Client survey Preliminary Design Work Style and merits of the design concepts Architectural

Embed Size (px)

Citation preview

Page 1: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

CafeShay TownsonMaddie Porter

Page 2: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Table of Contents Client survey Preliminary Design Work Style and merits of the design concepts Architectural style Green / Sustainable Design Aspects Codes and Regulations: 1 Codes and Regulations: 2 Revit Sheets Water Runoff Calculations and Water Management

Plan Parking caluculations

Page 3: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Client Survey Client-Toky Halls Modern but classic Bright Lots of natural light Warm colors Greenery surrounding it Drive through Green roof Electric appliances

Page 4: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Style and merits of the design concepts Our building is a bakery named Café.

The design of the building is to feel open, warm, and cozy.

The style is a post to reflect northern design.

Page 5: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Architectural style The Architectural style is Modern with

Italian in it. Also we kept Starbucks in mind when

designing.

Page 6: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Green / Sustainable Design Aspects/ LEED Credits Green roof

Rainwater Management

Energy efficient appliances

Page 7: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Preliminary Design Work

Page 8: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Codes and Regulations: 1 Section 154.04 Adoption of Rules by Reference the

International Building code that applies is the Indiana state building code in Noblesville, Indiana.

Section 303 Assembly Group A of International Building code of 2006 is what Indiana state building code is based on.

Section 503.1 of the IBC the occupancy classification of our building is A-2 which is retail that serves food.

IBC 2009 503.1 for the size and classification of our building any type of construction can be used.

IBC 2009 Table 503 the least restrictive would be type 2B and it doesn’t require fire protection.

Page 9: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Codes and Regulations: 2 The materials used would be wood with wood/tile floor. The occupancy load for the building is 13 people

according to IBC 2009 Section 1005 with the number coming from Kitchen load being 200 gross divided by the area of 2655 sq ft.

The minimum egress width is 28.6in according to IBC 2009 Section 1005 with 2.2 times the occupancy load of 13.

The minimum number of doors is 2 exits according to IBC 2009 Section 1021.

Yes we can have one exit with less than 49 occupants and less than 75 feet travel distance according to IBC 2009 Section 1021.2.

Page 10: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Revit

Page 11: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural
Page 12: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural
Page 13: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural
Page 14: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural
Page 15: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural
Page 16: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Water Runoff Calculations and Water Management Plan

Page 17: Cafe Shay Townson Maddie Porter. Table of Contents  Client survey  Preliminary Design Work  Style and merits of the design concepts  Architectural

Parking PlanTo find the required code for the parking spaces in your parking lot, you must figure the type of building that you are constructing. From that information, the code tells you that you must have a certain number of spaces per footage of your building. My partner and I calculated, using that information, our number of parking spaces for our building. We came out with thirteen parking spaces, included in that thirteen are two accessible spaces, or handicap spaces, with ramps on either side. In the parking lot, green space is required. We have a patch of green space at the front left corner of our building; it is rounded and gated with the curb of the street. In the green space there are multiple native plants of Indiana, and they are placed in and orientation to where it both shields the building from too much sun, or a storm, and gives the building a small taste of nature. The run off of the parking lot is 0.5539 cfs, and the runoff for the land or green space is 0.061 cfs