CABLES AND WIRES
Novi Sad, Republic of Serbia
CABLES AND WIRES
• SERBIA AND EX-YU Republics
NOVKABEL ADIndustrijska bb, 21000 Novi Sad, Republic of SerbiaTel: + 381 21 44 23 38 Fax: + 381 21 44 23 40 e-mail: [email protected] www.novkabel.com
• WESTERN EUROPE
East Point Holding Ltd.31 Evagoras Avenue, 6th (Floor) 1066 Nicosia CyprusTel: + 357 22 67 94 90 Fax: + 357 22 67 94 85e-mail: [email protected]
DP Handel GmbHWestendstrasse 24 D-60325 Frankfurt am Main GermanyTel: + 44 69 97 14 810 Fax: + 44 69 97 14 81 15e-mail: [email protected]
M POINT KFTFő utca 14-18 H-1011 Budapest HungaryTel: + 361 34 57 810 Fax: + 361 21 25 804e-mail: [email protected]
Romanian Trading Point S.LR.5,Str. Piata Romana Sector 1, 010671 Bucharest RomaniaTel: + 40 21 31 29 612 Fax: + 40 21 31 29 638e-mail: [email protected]
EPH Office, Sofia16, Fr.Jalio Kuriy Str, block 155, 2nd floor, apt 16, Izlak district, 1113 Sofia BulgariaTel: + 359 28 17 37 80 Fax: + 359 28 17 31 87e-mail: [email protected]
• CENTRAL AND EASTERN EUROPE
• RUSSIAN and CIS
EPH Office, MoscowMantulinskaya Street dom 5, str. 3 123100 Moscow Russian FederationTel: + 7 499 244 06 15/16 Fax: + 7 499 244 08 03e-mail: [email protected]
• USA
Metalco Corporation350 Fifth Ave. Suite 5022 Empire State Building NY 10118 New York USATel: + 212 239 69 98 Fax: + 212 239 82 81e-mail: [email protected]
• CHINA
YU POINT Ltd.Building No. 2-1-11 San Li Tun Diplomatic Compound Chaoyang District, 100600 Beijing PR ChinaTel: + 86 10 653 21 551 Fax: + 86 10 653 26 955e-mail: [email protected]
Sales Centers
1
NOVKABEL IS A RECOGNIZABLE PRODUCTION BRAND IN CABLE INDUSTRY OF SOUTHEAST EUROPE BEING A LEADING PROVIDER IN REGARD OF QUALITY AND PRODUCT RANGE.
Company profile
NOVKABEL, a member of
Point Group is a leading regional group with subsidiaries and associated companies that operate mainly in South East Europe. The core business activities of the Point Group are: copper processing and trading, wholesale grain trading, mill and bakery industry, river transport and real estate and engineering. The majority of the business operations take place in Serbia, Romania, Hungary and Austria. The Company also has offices in leading world cities: Moscow, New York, Frankfurt and Beijing.
About us
The Cable Factory based in Novi Sad was established in 1921 and is the oldest cable factory in the Balkans.We supply a wide range of energy cables and conductors, telecommunication cables and cables for electronic equipment to suit various industrial needs of construction industry, mining, shipbuilding, as well as oil, transportation, automotive industry and other industries.
ObjectiveNOVKABEL focuses on quality with utmost respect of the client's needs producing cables in accordance with quality standards and ecology requirements.Our objective is to remain market leader in the production and distribution of all types of cables, improving sales by finding new markets, expanding distribution network and strengthening relationships with business partners.
CapacityNovkabel production plant occupies an area of almost 40 hectares in the industrial zone of Novi Sad with the production capacity of up to 35.000 tons a year.
Research and developmentFrom its modest beginnings in the product range with a work of generations of employees on the development of new products, the factory has achieved about 16.000 registered products. NOVKABEL experts dedicate a lot of time to follow and implement the latest technical and technological achievements in cable industry.
QualityWe carry out all quality control procedures to ensure that all raw materials meet intake specifications and follow production until the dispatch of finished products, therefore the investment into control equipment is one of the Novkabel's priorities.
2 CABLES AND WIRES
SIGNAL CABLES
POWER CABLES
INSTALLATION PVC INSULATED CONDUCTORS
Type Standard Rated voltage Similar Application
PVC insulated and sheated cable for supply or remote control, at medium mechanical strains.
Screened, PVC insulated and sheated cable for supply or remote control, at medium mechanical strains.
Oil resistant, PVC insulated and sheated cable for supply or remote control, at medium mechanical strains.
Oil resistant, screened, PVC insulated and sheated cable for supply or remote control, at medium mechanical strains.
PVC insulated and sheated cable is used in urban networks and industrial plants, electric power plants and switchgear assemblies.
XLPE insulated and PVC sheated cable is used in urban networks and industrial plants, elec-tric power plants and switchgear assemblies.
XLPE insulated and PE sheated cable is used in urban networks and industrial plants, electric power plants and switchgear assemblies.
For connection devices where cable is expected to provide electrical protection.
H05V-U
H05V-K
H07V-U
H07V-R
H07V-K
H03VV-F
H03VVH2-F
H05VV-F
H05VVH2-F
NYM
NYSLY
NYSLYCY
H05VV5-F (NYSLYО)
H05VVC4V5 (NYSLYCYО)
N(A)YY
N(A)2XY
N(A)Y2Y
N(A)YCY
300/500 V
300/500 V
450/750 V
450/750 V
450/750 V
300/300 V
300/300 V
300/500 V
300/500 V
300/500 V
300/500 V
300/500 V
300/500 V
300/500 V
0,6/1 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV
PP00(-A)
XP00(-A)
PP40(-A)
DIN VDE 0281/3
DIN VDE 0281/3
DIN VDE 0281/3
DIN VDE 0281/3
DIN VDE 0281/3
DIN VDE 0281/5
DIN VDE 0281/5
DIN VDE 0281/5
DIN VDE 0281/5
DIN VDE 0276/603
DIN VDE 0245/102
DIN VDE 0245/102
DIN VDE 0281/13
DIN VDE 0281/13
DIN VDE 0276/603
DIN VDE 0276/603
DIN VDE 0276/603
DIN VDE 0276/603
P
P/M
P/F
PP/L
PP/J
PP
Single core non sheated cables are intended for wiring in pipes or raceways, for installations in the dry room, lighting equipment and control instruments.
Single core non sheated cables are intended for wiring in pipes or raceways, for installations in the dry room, lighting equipment and control instruments. U – wire; R – rope; K – flexible conductor
For connection of mobile user devices at low mechanical tensile strains.
For connecting of mobile electrical appliances at low and medium mechanical tensile strains, such as washing machines, vacuum cleaners...
In dry and wet conditions indoors and in the open air, for laying on plaster, in plaster or under plaster. Suitable for installations in food industries, laundries and so on.
3
POWER CABLES
Type Standard Rated voltage Similar Application
PVC insulated cable is used in urban networks, industrial plants and electric power plants, when mechanical damage could be expected.
XLPE insulated cable is used in urban networks, industrial plants and electric power plants, when mechanical damage could be expected.
For laying when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. For use in mines for electrical plants, equipments and installations in mines.
For laying when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. For use in mines for electrical plants, equipments and installations in mines.
In distributive lattice, industrial plants and power plants and always when better electrical protection is required.
For laying indoors, in ducts, directly in earth, in the open air in distribution networks, industrial plants and electric power plants. Laying down directly in the earth is limited by the mechanical properties of the PVC sheath.
For laying indoors, in ducts, directly in earth, in the open air in distribution networks, industrial plants and electric power plants.
In distributing network mains, industrial plants, middle-voltage and high voltage switchgear assemblies, thermo-power plants and electric power plants, when cables are exposed to aggresive and wet surrounding effects. For laying indoors, in ducts, in the open air, on cable trays, in earth and in the water.
For laying indoors, in ducts, in the open air, directly in earth, in urbane networks, industrial plants and power plants. Suitable for the networks which require minor reduction factor. Not provided for complicated conditions in terms of severe axial strains.
N(A)YBY
N(A)2XBY
N(A)YRGY
N(A)2XRGY
N(A)YFGY
N(A)2XFGY
N(A)YSY
N(A)2XSY
N(A)2XSEY
N(A)2XS2Y
N(A)2XSE2Y
N(A)2XS(F)2Y
N(A)2XS(FL) 2Y
N(A)2XSYBY
N(A)2XSEYB 2Y
0,6/1 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV
6/10 kV
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
PP41(-A)
XP41(-A)
PP44(-A)
XP44(-A)
PP45(-A)
XP45(-A)
PHP48(-A)
XHP48(-A)
XHE48(-A)
XHE49(-A)
XHP81(-A)
XHE81(-A)
DIN VDE 0276/603
DIN VDE 0276/603
DIN VDE 0276/603
DIN VDE 0276/603
DIN VDE 0276/603
DIN VDE 0276/603
DIN VDE 0276/620
DIN VDE 0276/620
DIN VDE 0276/620
DIN VDE 0276/620
DIN VDE 0276/620
DIN VDE 0276/620
DIN VDE 0276/620
DIN VDE 0276/620
DIN VDE 0276/620
4 CABLES AND WIRES
RUBBER CABLES
POWER CABLES
In urban networks, industrial plants and power plants, when the cable is exposed to severe mechanical tensile strains during laying down or use. For laying in ducts, in the open air and in earth.
In urban networks, industrial plants and power plants, when the cable is exposed to severe mechanical tensile strains during laying down or use. For laying in ducts, in the open air and in earth.
For distributive low-voltage air networks in urban areas, for air household connections.
For distributive low-voltage air networks in urban areas, for air household connections.
Self-supporting insulated wires are intended for distributive high-voltage air networks.
In the open air for public illumination (lamps carring is possible), for air household connections, site temporary connections, and so on. On pillars, support brackets or steel constructions.
Cable is intended for machine and hand welding with very high mechanical stresses.
Especially flexible cable is intended for machine and hand welding with very high mechanical stresses.
For supplying portable or light mobile appliances with low mechanical stresses (e.g. vacuum cleaners, electric irons, cooking appliances).
For supplying portable or light mobile appliances with low mechanical stresses (e.g. vacuum cleaners, electric irons, cooking appliances).
It is suitable for connecting electrical appliances and tools, including industrial and agricultural equipment with medium mechanical stresses.
Multicore cable is used for connection appliances with medium mechanical stresses. Cable is recomended if torsion stress exists.
N(A)2XSEY RGbY
N(A)2XSEY RGb2Y
N(A)2XSEY FGbY
N(A)2XSEY FGb2Y
NFA2X
SIP 3
XHP84(-A)
XHE84(-A)
XHP85(-A)
XHE85(-A)
X00-A
X00/O-A
PP/O
H01N2-D
H01N2-E
H05RR-F
H05RN-F
H07RN-F
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
0,6/1 kV
0,6/1 kV
12/20 kV
300/500 V
DIN VDE 0276/620
DIN VDE 0276/620
DIN VDE 0276/620
DIN VDE 0276/620
DIN VDE 0276
SRPS N.C5.250
GOST R 52373
SRPS N.C3.315
DIN VDE 0282-6
DIN VDE 0282-6
DIN VDE 0282-4
DIN VDE 0282-4
DIN VDE 0282-4
Production Specification of Novkabel
200 V
200 V
300/500 V
300/500 V
450/750 V
450/750 V
ZN/S
NFK EpG
EpN 50
NFK EpN 50
Type Standard Rated voltage Similar Application
5
RUBBER CABLES
Type Standard Rated voltage Similar Application
NSHTöu
NSSHöu
NSSHöu …/3
NSSHöu …/3E
NSSCHöu
NSSCHöu …KON
NTS … /3
NTS …/3E
NTS …KON
NSGAöu
NSGAFöu
NSGAFCMöu
BT
HT
NFK EpTN
EpN 53
EpN 55
EpN 63
EpN 78
EpN 78/53
EpN 74
EpN 65
ŽEpN
DIN VDE 0250-814
DIN VDE 0250-812
DIN VDE 0250-812
DIN VDE 0250-812
DIN VDE 0250-812
DIN VDE 0250-812
DIN VDE 0250-813
DIN VDE 0250-813
DIN VDE 0250-813
SRPS N.C5.364
DIN VDE 0250-602
DIN VDE 0250-602
DIN VDE 0250-602
UIC 895
0,6/1 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV 3,6/6 kV 6/10 kV
12/20 kV 20/35 kV
3,6/6 kV
0,6/1 kV 1,8/3 kV 3,6/6 kV
0,6/1 kV 1,8/3 kV 3,6/6 kV
3,6/6 kV
750 V
1500 V 3000 V
Cable is intended for connecting mobile appliances with high mechanical stresses, such as cable reels, lifting equipment, conveyor systems, driven motors, in dry, damp and wet conditions as well as outside.
Rubber flexible cables are intended for the operations in heavy conditions, in surface and methanes pit mines, shipyards, quarries and other type of industry.
Cables are intended for operating in extremely heavy conditions on surface pit mines, shipyards, quarries and industry. They are suitable for supply of heavy excavators, cranes truck transporters loading bridges and other machines.
Flexible medium voltage cable is intended for operation in mines with underground exploitation, for connecting high voltage movable transformer.
Rubber cable is intended for electrical vehicles.
Flexible rubber cable is used in electrical vehicles for current circuits for current for heating and control, as well as for lighting.
Flexible rubber cable with protective conductor is used in electrical vehicles for current circuits for current for heating and control, as well as for lighting.
Flexible rubber cable is used in electrical vehicles for current circuits for current for heating and control, as well as for lighting.
6 CABLES AND WIRES
RUBBER CABLES
Rubber flexible flat cable is used for connecting mobile parts of the machines, conveyor systems and large machines with medium mechanical stresses and torsion.
Silicone flexible flat cable is used for connecting mobile parts of the machines, conveyor systems and large machines as power, signal and control cable.
Flexible rubber cable is intended for pumps under water.
Rubber insulated cable is intended for fixed laying on ships and off-shore units, use in all rooms and on open board, as power, signalling and control cables.
Rubber insulated cable with protective conductor is used for fixed laying on ships and off-shore units, use in all rooms and on open board, as power, signalling and control cables.
Teledommunication shipboard cable is used for fixed laying on ships and off-shore units, use in all rooms and on open board, as signalling and control cables.
Halogen free single core non sheated cables with improved characteristics in the case of fire are intended for wiring, for installations in the dry room, lighting equipment and control instruments.
Halogen free single core non sheated cables with improved characteristics in the case of fire are intended for wiring in pipes or raceways, for installations in the dry room, lighting equipment and control instruments.
These cables are used for connecting electrical appliances and tools, and installations with medium mechanical stresses.
Halogen free cables, with concentric conductor (C) or not, are intended for installation in the object where there are rather large requirements for safety of people.
These cables, with concentric conductor (C) or not, are particularly suitable for installation which should be functional in the case of the fire (power supply pumps, equipment to extinguish a fire, ventilators for pulling out of smoke, panic lighting, etc).
DIN VDE 0250-609
Production Specification of Novkabel
Production Specification of Novkabel
DIN 89159
DIN 89158
DIN 89160
DIN VDE 0282-9
DIN VDE 0282-9
DIN VDE 0282-9
DIN VDE 0282-9
DIN VDE 0282-9
DIN VDE 0282-13
DIN VDE 0266
DIN VDE 0266
DIN VDE 0266
DIN VDE 0266
NGFLGöu
MGG
MGCG
FMGCG
H05Z-U
H05Z-K
H07Z-U
H07Z- R
H07Z-K
H07ZZ-F
NHXHX
NHXCHX
NHXHX FE180
NHXCHX FE180
300/500 V
300/500 V
450/750 V
0,6/1 kV
0,6/1 kV
250/250 V
300/500 V
300/500 V
450/750 V
450/750 V
450/750 V
450/750 V
0,6/1 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV
NFK SiSi/J
NFK TES
Type Standard Rated voltage Similar Application
HALOGEN FREE CABLES
7
HALOGEN FREE CABLES
Flexible halogen free cables are intended for installation in the object where there are rather large requirements for safety of people.
Flexible halogen free cables with concentric conductor are intended for installation in the object where there are rather large requirements for safety of people.
These flexible cables, with concentric conductor (C) or not, are particularly suitable for installation which should be functional in the case of the fire (power supply pumps, equipment to extinguish a fire, ventilators for pulling out of smoke, panic lighting, etc).
Flexible halogen free cables with improved characteristics in the case of the fire.
Flexible halogen free screened cables with improved characteristics in the case of the fire. Installation telecommunication cable for installation line or introducing several lines into buildings.For transmission of analogous and digital signals. For installation in areas with risk of fire.
Installation telecommunication cable for installation line or introducing several lines into buildings.
For installation line on place where is indispensable to reflect communication in fire long period of time. Also suitable as fire alarm cable.
Installation halogen free cables with improved characteristics in the case of the fire.
Installation halogen free cables with improved characteristics in the case of the fire.
Power halogen free cables with improved characteristics in the case of the fire.
Power halogen free and screened cables with improved characteristics in the case of the fire.
Halogen free cables is used in distribution networks, industrial plants and electric power plants, when mechanical damage could not be expected.
Production Specification of Novkabel
Production Specification of Novkabel
Production Specification of Novkabel
Production Specification of Novkabel
Production Specification of NovkabelProduction
Specification of Novkabel
DIN VDE 0815
DIN VDE 0815
DIN VDE 0815
DIN VDE 0815
DIN VDE 0250/215
DIN VDE 0250/214
DIN VDE 0276/604
DIN VDE 0276/604
DIN VDE 0276/622
DIN VDE 0276/622
LiHXHX
LiHXCHX
LiHXHX FE180
LiHXCHX FE180
LiHH
LiHCH
J-HH
J-2Y(St)H
J-H(St)H
JE-H(St)H
NHMH
NHXMH
N2XH
N2XCH
N(A)2XSH
N(A)2XSEH
0,6/1 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV
250 V
250 V
300 V
300 V
300 V
300 V
300/500 V
300/500 V
0,6/1 kV
0,6/1 kV
6/10 kV 12/20 kV 20/35 kV
6/10 kV 12/20 kV 20/35 kV
Type Standard Rated voltage Similar Application
8 CABLES AND WIRES
HALOGEN FREE CABLES
Halogen free cables is used in urbane networks, industrial plants and power plants, when mechanical damage could be expected.
Halogen free cable is used for fixed laying on ships and off-shore units, use in all rooms and on open board, as power, signalling and control cables.
Halogen free cable with protective conductor is used for fixed laying on ships and off-shore units, use in all rooms and on open board, as power, signalling and control cables.
Screened halogen free cable is used for fixed laying on ships and off-shore units, use in all rooms and on open board, as signalling and control cables
For transmission of low-frequency commands in signalling equipment.
For transmission of low-frequency commands in signalling equipment.
For installation line or introducing several lines into buildings.
As leadingin insulated conductor in dry and damp operating area.
For installation line or introducing several lines into buildings.
Installation cable for permanent connection in industrial electronics.
Low-frequency telephone subscriber cable with foam and skin PE insulation is used in local network for subscriber and trunk lines.
Low-frequency telephone subscriber cable with solid PE insulation is used in local network for subscriber and trunk lines.
Filled low-frequency telephone subscriber cable with solid PE insulation is used in local network for subscriber and trunk lines. It is laid in cable ducts or into the ground.
Self-supporting low-frequency telephone subscriber cable with solid PE insulation is used in local network for subscriber and trunk lines. It is laid at supports on the ground walls, rooves.
DIN VDE 0276/622
DIN 89159
DIN 89158
DIN 89160
DIN VDE 0813
DIN VDE 0813
DIN VDE 0815
DIN VDE 0815
DIN VDE 0815
DIN VDE 0815
DIN VDE 816
DIN VDE 816
DIN VDE 816
PTT, Serbia
6/10 kV 12/20 kV 20/35 kV
0,6/1 kV
0,6/1 kV
0,6/1 kV
N(A)2XSEHBH
MGH
MGCH
FMGCH
S-YY
S-Y(St)Y
J-YY ... Bd
2YY
J-Y(St)Y
JE-Y(St)Y
A02Y(L)2Y... St III Bd
A2Y(L)2Y... St III Bd
A2YF(L)2Y... St III Bd
TK 33 U
Type Standard Rated voltage Similar Application
TELECOMMUNICATION CABLES
9
TELECOMMUNICATION CABLES
Filled low-frequency subscriber cable with solid PE insulation is used in local network for subscriber lines, for direct laying into the ground.
Filled low-frequency subscriber cable with foam and skin PE insulation is used in local network for subscriber lines, for direct laying into the ground.
Filled low-frequency subscriber cable with foam and skin PE insulation is used in local network for subscriber lines where the inductive influence of power lines is to be expected.
Filled low-frequency subscriber cable with foam and skin PE insulation is used in local network for subscriber lines where great influence of power lines is to be expected.
Low-frequency cable for network group with foam-skin PE insulation is used in local network for trunk lines.
Installation cable for computer networks is used in local networks for data transfer or in networks for automatic control.
Self-supporting low-frequency cable is used in network group for trunk lines when there is the inductive influence of power lines.
Cable for digital transmission is used in network groups for low-frequency transmission or digital transmission up to 2Mbits/s.
Armoured cable for digital transmission is used in network groups for low-frequency transmission or digital transmission up to 2 Mbits/s. It is laid directly into the ground.
Symmetrical pair cable for digital transmission (up to 30 MHz), is used in local network for subscriber lines.
Flat telephone cord for connector connections are intended for connecting telephones with telephone installation.
Control cable for differential protection-voltage difference measurement or the current at input and output of power equipment.
PE insulated cables for the connection of railway station signalsafety units on electrified railwaytracks.
PVC insulated cables for the connection of railway station signalsafety units on electrified railwaytracks.
PTT, Serbia
PTT, Serbia
Production Specification of Novkabel
Production Specification of Novkabel
DIN VDE 816
DIN VDE 0815
PTT, Serbia
PTT, Serbia
PTT, Serbia
PTT, Serbia
PTT Serbia
Production Specification of Novkabel
JŽS, Serbia
JŽS, Serbia
TK 39 TP ... M, GM
TK 59 TP ... M, GM
TK 59 MR, GMR
TK 59 MRL, GMRL
A02Y(L)2Y... St I Bd
J-2Y(St)Y
TD 36 U-P
TD 39 M
TD 59 TP, OP
TK 59 DSL (30)
PGA4
DP
SEZ
SPZ
Type Standard Rated voltage Similar Application
10 CABLES AND WIRES
WIRING CONDUCTORS
CABLES FOR AUDIO SYSTEMS
Type Standard Rated voltage Similar Application
As installation insulated conductor in dry and damp operating area.
As insulated conductor for wiring in telecommunication or data processing devices.
Equipment wires (flexible conductor) with insulation of PTFE mass, are intended for wiring of electronic and electric devices where working conditions are demanding high temperatures (up to 250°C)
Equipment wires (flexible conductor) with insulation of FEP mass, are intended for wiring of all kinds of electronic and medical devices
Equipment wires (flexible conductor) with insulation of ETFE mass are intended for automatic or semi-automatic panel connection in computer technics, in telephone centrals and aero industry for wiring of all devices that need high level of mechanical resistance.
Sub miniature cable is intended for performing internal connections between some points inside audio devices, where screening of audio signal is needed for protection from the disturbance.
One- pair audio cables is used in professional audio systems of all kinds. It is intended for production of connecting cables with XLR connectors and transmission of the microphone signal.
Multi pair audio cable is being used everywhere where is grouping of the related lines needed for transmission of the signals with optimal usage of the available space.
Cable is intended for connection of the technic speaker-phones three- wire asymmetric connection configuration, with movable connecting cables with XLR connectors.
Cable are being used for production of flexible connections between power amplifier and loudspeakers in studio monitor systems and professional sound systems.
DIN VDE 0815
DIN VDE 0812
DIN VDE 0881
DIN VDE 0881
DIN VDE 0881
Production Specification of Novkabel
Production Specification of Novkabel
Production Specification of Novkabel
Production Specification of Novkabel
Production Specification of Novkabel
Y
YV
(Li)5Y
(Li)6Y
(Li)7Y
TM 20
TI 20
NAUK 001 NAUK 002 NAUK 003
NAUK 100
NAUK 200
NAUK 300
NAUK 900
11
OPTICAL FIBER CABLES
ELECTRONIC CABLES
Optical fiber cable is suitable for indoor and outdoor aplications.
Non- metallic optical fibre cables are specially suitable for the application on relation along with electro- tractive lines, in the areas with common discharging and in the transfer equipment of the electric economy because they are totaly unsensitive for all kinds of electromagnetic influences and atmosphere discharging.
Optical fiber cables manufactured according to these technical conditions can be used in local telephone networks as a connecting cables, in long- distance telephone networks as a long- distance cables.
Coaxial cable with RG mark and characteristic impedance of 50 Ω, is intended for general usage in professional telecommunication technics and radio amateurism. During the transmission of VF signals through these cables it comes to generating of exceptionally small noise.
Coaxial cable with RG mark and characteristic impedance of 75 Ω, is being used in a wide range of commercial electronics and high- frequent technics and everywhere where is transmission of VF signals with less noise transmission needed.
Conductors for overhead power lines.
Conductors for overhead power lines.
Flexible cable is intended for connection in measuring, control and regulation technique. It is used for wiring of telecommunication equipment and equipment for data processing too.
Flexible screened cable is intended for impulse and data transmission in electronics, computer technics, control, measuring and regulation technics.
Production Specification of Novkabel
PTT, Serbia
PTT, Serbia
MIL C-17/28C,
MIL C-17/74C
MIL C-17/78B
MIL C-17/77C
DIN 48 204
DIN 48 201
DIN VDE 0812
DIN VDE 0812
OKZPP1
TO SM 03
TO SM 19
RG 50 Ω
RG 75 Ω
Aluminium conductors,
steel - reinforced
Hard copper and bronze
stranded conductors
LiYY
LiYCY
250 V
250 V
Type Standard Rated voltage Similar Application
COAXIAL CABLES
UNINSULATED CONDUCTORS
12 CABLES AND WIRES
UNINSULATED CONDUCTORS
For the cable industry.
For the cable industry.
For use in cable industry and for other products like rivets, ect.
In cable industry, for elektrotechnical and other products.
For the cable industry.
They are used for connections with earth connections in electronics and in automobile industry for brushes in electromotors.
They are used for the grounding of the electrical units, and in the automobile industry.
For partial screening and similar applications in electronics.
They are used for connections with earth connections in electronics and in automobile industry for brushes in electromotors.
For use in sparc erosion units which use wire as electrode. Using MCV wire enable faster cutting up to 30%.
For sieves, and other products of general purposes.
DIN VDE 0295
class 2
DIN VDE 0295
class 1,2,5,6
DIN VDE 0295
class 2
DIN VDE 0295
class 1,2,5,6
DIN VDE 0295;NF C 32-321;
SRPS N.C0.015
class 2
DIN 46444
DIN 72 333
Production Specification of Novkabel
DIN 46440
Production Specification of Novkabel
SRPS C.D1.120
Aluminum conductors
Round stranded
conductors - copper
(bare or tinned)
Aluminum wires
Copper wires (bare
or tinned)
Profiled stranded
conductors of copper
and aluminum
Very flexible flat braid
Flat braid
Very flexible braid
Stranded conductors with overall
copper braid
Wire for erosimat zinc plated copper
wire (MCV)
Brass wire MS 63
Type Standard Rated voltage Similar Application
Certificate
member of
NOvkABEL AD
Industrijska bb, 21000 Novi Sad, Republic of Serbia Tel: + 381 21 44 23 38 Fax: + 381 21 44 23 40
e-mail: [email protected] www.novkabel.com
POINT GROUP
Francuska 6, 11000 Belegrade, Republic of Serbia Tel: + 381 11 33 46 444 Fax: +381 11 32 34 431
e-mail: [email protected] www.point-group.com