CA-MDS-BHC

Embed Size (px)

Citation preview

  • 8/13/2019 CA-MDS-BHC

    1/30

    MDS-R410A-2008

    MULTI DIGITAL SCROLL UNITS

    MODEL: MDS050B(R)5-MDS500B(R)5

    COOLING CAPACITY: 13.5kW-134kW

    HEATING CAPACITY: 15kW-148kW

    Catalogue

    Engineered for flexib il ity and performance.TM

  • 8/13/2019 CA-MDS-BHC

    2/30

    For More Than a Century, McQuay has been Devoted to

    Different Buildings

    Global headquarters of McQuay (Minneapolis,

    USA)

    McQuay Staunton Factory, USA McQuay Aubum Factory, USA McQuay Cecchina Factory, Italy

    McQuay Shenzhen Factory, China Workshop of McQuay Shenzhen Factory,

    China

    Test center of McQuay Shenzhen Factory,

    China

    Sound test room of McQuay Shenzhen Factory,

    China

  • 8/13/2019 CA-MDS-BHC

    3/30

  • 8/13/2019 CA-MDS-BHC

    4/30

    oft

    anitary

    imple

    Based on the success of MDS Variable Digital Multi system of normal temperature series,

    McQuay MDS BHC High ambient temperature series is a new generation of multi-scroll units.

    They ideally combine the cutting-edge digital technology with high adaptability of atrocious

    environment. In addition, this series features higher performance, higher capacity, lower

    sound, easier installation, and stronger system management, taking the lead in the market.

    Page 4

    McQuay Multi Digital Scroll High Temperature Series

  • 8/13/2019 CA-MDS-BHC

    5/30

    Page 5

    ModelCapacity range

    0.8HP 1.0HP 1.5HP 1.8HP 2.0HP 2.5HP 3.0HP 4.0HP 5.0HP 6.0HP 8.0HP 10.0HP

    MCC Ceiling concealedunits

    MCK Ceiling cassetteunits

    MDB High static pressureduct units

    MCMCeiling exposed /

    oor standing units

    MWM Wall mounted units

    ave energy

    trong

    ilence

    Indoor Unit Line-up

    18

    20

    24

    26

    22

  • 8/13/2019 CA-MDS-BHC

    6/30

    Page 6

    Featuring Leading-edge Digital Technology

    McQuay Multi Digital Scroll High Temperature Series

    MDS100B system 100%

    5%

    Loading

    operating

    operatingoperating

    Unloading

    An optimization cooling-circuit design makes the

    unit more efcient. Take MDS120BHC for example:

    it's EER is up to 3.5 (35cooling condition at full

    load), which is much higher than Normal styling.

    High adaptability to Wider Operation Range

    Specially designed BHC series multi digital scroll

    units are suitable for high ambient temperatureapplication up to 52.

    Enlarged condensing coil can effectively lower

    the discharge pressure and make the system run

    safely at high ambient temperature.

    Fan motor is des igned fo r h igh ambien t

    temperature running.

    Electrical parts are selected for high ambient

    operation.

    Exhaust fan can maintain the internal temperature

    inside the control box at an accepted level even

    under very high ambient temperature to make the

    controllers and electrical parts work properly.

    Fins are protected by a special paint in gold colorto give better protection against corrosion in

    aggressive environment.

    High EER

    Exhaust fan in control cabinet.

  • 8/13/2019 CA-MDS-BHC

    7/30

    Page 7

    Traditional air conditioners

    MDS digital variable multi system

    Initial temp.:

    30

    Set temp.:

    25

    trong

    MDS digital variable multi BHC series units feature stronger cooling

    performance in high ambient temperature, stepless capacity modulation

    and accurate temperature control, thus making your space more

    comfortable.

    Superior Cooling & Heating Performance

    Specially designed MDS digital variable multi BHC series

    feature leading-edge unit design and superior heating

    performance. They have undergone strict system match

    and performance test, and work well in anbient temperature

    as high as 52.

    Quick Achieving the Set Temperature

    In MDS digital variable multi systems, heat transter is happened directly between the refrigerant and air.

    And equipped with a smart temperature controller, the unit can achieve the set temperature quickly. Also

    the indoor temperature uctuates very little, making your room more comfortable.

    Wider Capacity Modulation Range

    The compressor of MDS digital variable multi systems feature 10% ~ 100% stepless capacity modulation

    range. Thanks to this, the unit can provide cooling/heating capacity exactly as required. Compared

    with traditional invert systems (step output), MDS digital variable multi systems feature wider capacitymodulation range, and save more energy.

    Coolingcapacity%

    MDS digital variable

    capacity system

    Variable frequency

    system

    Taking 10HP units for example

    Capacity %

    52

  • 8/13/2019 CA-MDS-BHC

    8/30

    Page 8

    Featuring Leading-edge Digital Technology

    McQuay Multi Digital Scroll High Temperature Series

    AC

    Capacity modulation controller Capacity controller

    ACAC ACDC

    DCDC

    Converter Transducer

    Motor loss = 5 ~ 10%

    Variable frequency CompressorPWM valve control

    Modulation loss = 0%

    MDS digital variable multi system Traditional invert system

    Digital

    compressor

    Modulation loss = 10%

    ave energy

    MDS digital variable multi systems feature leading-edge digital

    capacity modulation design, thus saving more energy and

    reducing electricity cost.

    High EERMDS BHC units feature leading-edge system design

    and higher EER, thus saving more energy compared

    with traditional air conditioners.

    For most time around the year, air conditioners work

    at a partial load. Seasonal EER is the main index

    for judging whether the unit is more energy-efcient.

    MDS digital variable multi systems feature high

    EER at full capacity, and even higher EER at partial

    capacity. Thanks to this, they can save more energyand effectively reduce the electricity cost.

    MDS digital variable multi systems feature

    high seasonal EER. They can achieve better

    heating and cooling performance with less power

    consumption. Compared with traditional systems,

    MDS digital variable multi systems can save up to

    45% electricity cost.

    Traditional central air conditioning system

    Energy Saving and Cost Effective

    Digital stepless capacity modulation with a wider

    range

    Less on/off operations and smaller startup current

    5% ~ 20% less capacity modulation loss

    compared with invert systems

    When the digital compressor is unloaded, the

    power of the unit is reduced to 10% of the full

    load power.

    Digital variable capacity system

    No invert loss, thus reducing power consumption

    While working at partial load, the outdoor unit supplies heating/cooling capacity to the indoor units

    exactly as necessary, thus eliminating bypass power consumption.

  • 8/13/2019 CA-MDS-BHC

    9/30

    Page 9

    oft

    Temperature

    Time

    Temperature fluctuation of traditional household air-conditioners: 2 C

    Temperature fluctuation of traditional variable frequency system: 0.5C

    Temperature fluctuation of MDS digital variable capacity system: 0.3 C

    Environment Temperature ()

    Variable f requency system

    MDS digital variable capacity system

    Cooling capacity (kW)

    Note: take MDS100BHC for example

    MDS digital variable multi systems ideally integrate leading-edge air

    handling technology, accurate temperature control technology and

    reliable smart multi-scroll technology. They are designed to make your

    room more comfortable and fresh.

    Accurate Temperature Control and Quick Response

    The capacity requirement for air conditioners changes

    according to lots of factors, such as ambient temperature

    and sunshine. Therefore, it would be much better if the

    air conditioners feature stepless capacity modulation and

    quick response. Otherwise, the temperature uctuations

    will make people feel uncomfortable.The brand new

    MDS digital variable multi systems feature stepless

    capacity modulation, and can change output capacity

    instantly. Therefore, they can provide cooling/heating

    capacity as required. Whats more, accurate temperature

    control also makes your room more comfortable.

    Dry bulb temperature control can be as accurate as 0.3

    Unique and dynamic load forecast technology

    Leading-edge and continuous load tracing technology

    Quick capacity modulation: instantly changing from 10% to 100%

    The electronic expansion valve is quick in response, thus making temperature control more accurate and

    reducing the time needed to achieve the set temperature.

    Excellent Dehumidication PerformanceIn hot and wet days, the humidity of indoor air increases

    sharply, thus making people feel very uncomfortable. MDS

    digital variable multi systems feature better dehumidication

    performance. Even during the hot and wet rain season, they

    can make your room comfortable and brisk.

    MDS digital variable multi systems work at a lower sensible

    heat ratio. The suction pressure is lower than that of VRV

    systems. Therefore, they feature stronger dehumidicationperformance.

  • 8/13/2019 CA-MDS-BHC

    10/30

  • 8/13/2019 CA-MDS-BHC

    11/30

    Page 11

    oft

    High frequency harmonic waveHigh frequency harmonic wave

    MDS digital variable capacity system

    EMC comparison diagram

    EMC regulations

    Variable frequency system

    Excellent Electromagnetic Compatibility

    While modulating capacity, MDS digital variable multi systems only

    shift precision parts, and produce no high frequency harmonic

    wave. Therefore, they will not destroywith high delity sound boxes,computers, telephones etc. They can be widely used in places where

    interference with the power supply must be strictly prohibited, such

    as computer rooms, telecom base stations, TV broadcast reception

    stations and telecom equipment rooms.

    As the frequency signal changes, high frequency systems will

    generate high frequency harmonic waves with frequencies 5, 7,

    11, 13, 17 19 times as high as that of the power supply. As

    a result, the power factor of the electricity network is reduced,

    the capacitor and transformer overheat, ashing points appear

    at the uoroscopes and oscillographs, and the precision

    of precision instruments are lowered.The electromagnetic

    interference (EMI) of invert systems are now internationally

    deemed as an environmental pollution. The electricity costspent on suppressing EMI also makes users sweat.

  • 8/13/2019 CA-MDS-BHC

    12/30

    Page 12

    Featuring Leading-edge Digital Technology

    McQuay Multi Digital Scroll High Temperature Series

    Fresh air

    Return air

    Air supply

    Note: The above pipelining only serves as an example. For MCK

    pipelining, please refer to the manual.

    anitary

    Fresh Air Replacing

    MDS digital variable multi systems feature leading-edge air purication

    technology. They can dampen the breeding of bacteria and improve air

    quality, thus making your room more sanitary and comfortable.

    Each room can be equipped with an independent fresh

    air processing unit, and takes in fresh air freely. In this

    way, it improves the indoor air quality and makes your

    room more comfortable. You can breathe in fresh air

    right inside your room. Optional HRB heat recycling units

    facilitate both fresh air suctionand energy saving.

    Dampening the Breeding of Bacteria

    Scientic research shows the breeding of bacteria increases

    as the air humidity increases.MDS digital variable multi

    systems feature excellent dehumidication performance.

    Therefore, they can effectively dampen the breeding of

    bacteria, and prevent articles from going moldy. In this

    way, they can prevent the indoor air from being polluted,

    and greatly improve indoor air quality.

    Excellent Disinfection Performance

    You can choose to equip ceiling concealed units with

    air lters manufactured by McQuays brother company

    AAF (American Ail Filter). Such air lters contain the

    disinfectant lNTERSEPT. Research shows that they

    can effectively dampen the breeding of organisms, and

    improve indoor air quality (IAQ).

  • 8/13/2019 CA-MDS-BHC

    13/30

    Page 13

    ilence

    MDS digital variable multi systems feature leading-edge sound absorbing

    technology, and operate more quietly.

    Using a new type of spiral blades, the outdoor unit features smooth air draft structure, signicantly reducing

    the turbulent ow and lowering the airow sound level.

    New type of spiral blades V heat exchanger Sound-insulation design for thecompressor

    Based on state-level sound test room and frequency analysis, all parts such as fans and motors are

    carefully compared, improved and chosen. The structure and pipeline also feature professional sound

    absorbing design, signicantly reducing the sound level of the unit.

    Sound frequency analysisState-level precision sound test room

    Innovative night silence mode (cooling) for the outdoor unit can automatically modulate the fan

    speed as the ambient temperature changes. Therefore, the unit can work more quietly and save more

    energy.

    MDS digital variable multi systems can work more smoothly and quietly

  • 8/13/2019 CA-MDS-BHC

    14/30

    Page 14

    Featuring Leading-edge Digital Technology

    McQuay Multi Digital Scroll High Temperature Series

    The outdoor unit of MDS system is designed as package, the

    compact structure occupies less space and is easy to move.

    The outlines and dimensions of the innovated units are

    compact. They can be installed side by side to save space.

    The refnet joint is provided by the factory in accordance

    with different indooe units, which will reduce the work force

    at site and save a lot of money.

    Only the refrigerant pipe is needed for MDS system, which

    can save you a lot of money because there is no chilled water

    piping and other accessories.

    The outdoor units can be located on the rooftop, which saves

    space and is convenient for installation. The depth and height

    of all the units are the same. When they are located together,

    they look elegant.

    MDS system is designed to a capacity modulation systemwithout oil circle. Piping length between outdoor unit and in-

    door unit can be extended up to 150 meters. The heighr be-

    tween outdoor unit and indoor unit can be extended up to 50

    meters when the outdoor unit is above the indooe unit. (If the

    outdoor unit is below the indoor unit, the height between them

    can be up to 40 meters.) The height between different indoor

    units can be extended up to 15 meters, which enables a single

    system to cover 4 or 5 floors. For different model condensing

    unit, factory recommends the different limit. The left drawing is

    just for your reference.

    impleThe MDS system are simple and reliable, the design and installation

    are more exible.

  • 8/13/2019 CA-MDS-BHC

    15/30

    Page 15

    MDS

    MDS

    Capable of monitoring 1024 (32x32) indoor units

    simultaneously in real time

    Central ControlMDS system can be connected up to 32 indoor units. 32 outdoor units can be controlled in a network through

    a centralized controller. The monitor software can monitor 1024 (32x32) indoor units in real time at the same

    time. The communication cables between indoor units and outdoor units are very easy to arrange. MDS system

    has a strong function of displaying the malfunction, which can save maintenance time and cost.

    MDS system real time control interface

    Reliable

    MDS system adopts the advantaged capacity modulation technology to reduce the control devices, which

    reduce the malfunction odds mostly.

    MDS system has excellent oil return performance even at low capacities, which will make sure that all of the

    removable parts of the compressor can be lubricated and cooled down. Thus, the compressor remains

    reliable throughout operation.

    It reduces the start/stop times, which will reduce the attack to the electricity supply net.

    The PWM (Pulse Width Modulation) valve has the longevity of 40 million times.The design is simple and there is no requirement for bypass valve.

    Wired control + Remote control Remote control Central control

    Dongle Key

    McQuay Software Management System

  • 8/13/2019 CA-MDS-BHC

    16/30

    Page 16

    Featuring Leading-edge Digital Technology

    McQuay Multi Digital Scroll High Temperature Series

    Real-time Monitor

    System monitor software: Powerful MDS real-time monitor software can implement indoor control, system

    control, circuit control and service control. It helps users or serving personnel to view detailed parameters and

    unit data.Description of main control functions:

    Indoor Monitoring

    System Monitoring

    Display the types and status of all the indoor units in the system, including alarm and timing.

    Circuit Monitoring*Select and view the system diagram, running parameters of outdoor units, and

    running parameters of all the indoor units.

    Service Monitoring*

    The current running parameters and the curves of history records of outdoor

    and indoor units can be displayed.

    Note: * Only authorized maintenance personnel can use this window.

    Set the mode, fan speed, auxiliary setting, and temperature of indoor units. Switch on/off indoor units.(You

    can operate several units or several machines in several units at the same time.)

    Set indoor units and outdoor units in groups. You can customize the group settings. (The default groups are

    by outdoor units.)

    Display alarms and check alarms. (You can check malfunction of outdoor or indoor units by selecting

    numbers.)

    Set timing mode and set the timing mode of indoor units. (You can set and save the timing mode of the unitswithout any limitation.)

    Description of icons of indoor units:

    Small icon

    Description

    The timing

    function of

    this indoor

    unit is

    enabled

    The wired

    controller of

    this indoor unit

    is locked. You

    cannot control

    it through the

    cable controller.

    Faults occur to

    this indoor unit.

    Double-click this

    icon to view the

    details.

    Description of icons of each type:

    Icon

    Switching off Cooling Heating Dehumidifying Ventilating

    MCK

    TYPE

    MCC

    MDB

  • 8/13/2019 CA-MDS-BHC

    17/30

    Page 17

    Flexible and Convenient Selection Software

    The selection software designed for different models allows you to select and verify unit models as required

    by customers, and determine the models of indoor and outdoor units as well as the required quantity of refnetjoints and pipes. Thus, the selection software enables you to carry out complex unit design and selection

    more easily and quickly with a single click.

  • 8/13/2019 CA-MDS-BHC

    18/30

    Page 18

    Featuring Leading-edge Digital Technology

    McQuay Multi Digital Scroll High Temperature Series

    Ceiling Concealed MCC Series Indoor Units

    Leak-proofdrain pan

    Taking in outdoorfresh air

    Wireless remote(optional)

    The design of McQuay ceiling concealed indoor units takes into account

    the space module, small partition and other features of modern commercialbuildings. Cooled/heated air is supplied to all parts of the room evenly, causing

    no indoor temperature difference. The units also timely rell the room with

    fresh air, thus completely eliminating air conditioning related harm. Whats

    more, the air conditioner and air duct are concealed and match well with the

    indoor upholstery, thus saving space and facilitating installation.

    Autodehumidication

    Auto failuredetection

    Air ow modulation Silence mode Anti-mildew lter Timed on/off Auto restart after powerfailure (optional)

    Features

    Miniaturized central air conditioner

    Similar to large central air conditioners, the indoor units and air

    duct are installed inside the ceiling and takes up no additional

    space. Therefore, they match well with the indoor upholstery.

    Optional ESP

    To supply conditioned air over different distances, various static

    pressure levels are applied to units according to their cooling

    capacities. To change the static pressure, you just need to change

    the motor connection wire.

    The control system features microprocessor wire controller and

    LCD display, and provides several operation modes for you to

    choose from.

    Intelligent control Quiet operation

    The centrifugal fan of the indoor unit features wide and efcient

    blades, and forward curved double suction. The fan rotates

    slower, and produces less sound. However, it generates stronger

    air ow.

    Super thin

    The indoor unit is as thin as 250 mm (220mm for MCC008T-015T)

    upholstery cost. Concealed installation saves both space and

    upholstery cost. The air supply outlet matches perfectly with the

    indoor upholstery, and makes your room more beautiful.

    Easier to installation

    The left and right connection pipes can be exchanged (for

    MCC008T-020T). A condensate pump with lift up to 500 mm is

    also available. Therefore, installation becomes much easier.

    Left connection pipe

    Right connection pipe

    Optional

  • 8/13/2019 CA-MDS-BHC

    19/30

    Page 19

    Notes:

    1) All specication are subjected to change by the manufacturer without prior notice.

    2) Nominal cooling capacity is based on 27DB, 19WB indoor temp. and 35DB outdoor temp.

    3) The external static pressure data in bracket are adjustable, they can be achieved by changing the connectors inside the junction box.

    4) Sound level are measured in an 11.5dBA background sound level anechoic chamber for units without return air plenum.

    Ceiling concealed indoor units

    Model MCC008T MCC010T MCC015T MCC018T MCC020T MCC025T MCC030T MCC040T MCC050T MCC060T

    Nominal coolingcapacity

    kW 2.0 2.5 3.65 4.5 5.6 6.5 7.8 10.6 12.4 14.4

    Btu/h 6830 8540 12470 15370 19130 22200 26640 36200 42350 49180

    Power supply V/Ph/Hz 220 - 240 / 1 / 50

    Rated power input kW 0.047 0.047 0.081 0.082 0.082 0.123 0.158 0.276 0.276 0.28

    Net weight kg 22 22 22 25 25 27 28 39 39 45

    Unit dimension (WxDxH) mm 1054469220 1314490251 1664490251 1924490251

    Air ow (H/M/L)m3/h 460/370/280 580/470/380 800/650/540 960/780/600 1200/950/800 1900/1520/1300 2100/1750/1460

    CFM 255/218/165 341277/224 471/383/318 565/459/353 706/559/471 1118/895/765 1236/1030/859

    Sound level (H/M/L) dB(A) 31/29/27 34/32/30 35/32/29 37/36/35 42/40/38 47/45/43 48/46/44

    External static pressure Pa 15(0/30/50) 30(15/50/70) 50(15/30/70)

    Filter Nylon

    Liquid pipe mm(in) 6.35(1/4) 9.52(3/8)

    Gas pipe mm(in) 9.52(3/8) 12.7(1/2) 15.88(5/8) 19.05(3/4)

    Drain pipe mm(in) 19.05(3/4)

  • 8/13/2019 CA-MDS-BHC

    20/30

    Page 20

    Featuring Leading-edge Digital Technology

    McQuay Multi Digital Scroll High Temperature Series

    Autodehumidication

    Auto failuredetection

    Taking in outdoorfresh air

    Auto swing

    Air ow modulation Silence mode Anti-mildew lter Timed on/off Auto restart afterpower failure

    (optional)

    Wireless remote Leak-proofdrain pan

    Prevent theceiling from being

    polluted

    Ceiling Cassette MCK Series Indoor Units

    When the ceiling cassette MCK series indoor units are installed, you can only

    see the panel. Cooled/heated air is supplied evenly in four directions, makingmodern apartments and ofces more comfortable.

    Features

    Handsome appearance

    Trendy appearance design matches well with indoor upholstery,

    and adds more grace to your room.

    Microprocessor control

    Using a smart wireless remote, you can set the working mode,

    the fan speed, the on/off time etc. The unit also features accurate

    temperature control and energy saving, making your room more

    comfortable.

    Low operation sound

    With leading-edge 3-D spiral blades and optimized air duct

    design, the unit operates with very little sound

    Taking in outdoor fresh air

    The unit takes in more fresh air, making the air in your room

    fresh and healthy. Therefore, air conditioning related syndromes

    are completely eliminated.

    Washable anti-mildew lter

    The lter can be easily and conveniently washed. It keeps the

    indoor air fresh and clean. Meanwhile, it can also get rid of

    unfavorable smells by using absorbent material.

    Smooth water drainage

    Built-in automatic high-pressure condensate pump can pump out

    water up to 500mm high.The lter is optional.

    Washable anti-mildew lter

    500mm

  • 8/13/2019 CA-MDS-BHC

    21/30

    Page 21

    Ceiling cassette indoor units

    Notes:

    1) All specication are subjected to change by the manufacturer without prior notice.

    2) Nominal cooling capacity is based on 27DB, 19WB indoor temp. and 35DB outdoor temp.

    3) Sound level are measured in an 11.5dBA background sound level anechoic chamber.

    Model MCK010T MCK015T MCK018T MCK020T MCK025T MCK030T MCK040T MCK050T MCK060T

    Nominalcoolingcapacity

    kW 2.8 3.6 4.5 5.4 6.5 7.5 10.0 12.5 14.0

    Btu/h 9560 12290 15370 18440 22200 25610 34150 42690 47810

    Power supply V/Ph/Hz 220 - 240 / 1 / 50

    Rated powerinput

    kW 0.028 0.029 0.040 0.043 0.075 0.084 0.110 0.140 0.155

    Net weight(with panel)

    kg 26 (34) 30 (38) 39.5 (47.5)

    Unit dimension(WxDxH)(with panel)

    mm 905905250 (930930278) 905905335 (930930363)

    Air ow (H/M/L)m3/h 500/400/330 590/490/430 670/560/490 720/610/520 1200/1100/960 1300/1060/850 1360/1200/1110 1650/1450/1350 1800/1500/1350

    CFM 294/235/194 347/288/253 394/330/288 424/359/306 706/645/565 765/624/500 800/706/653 971/853/795 1059/883/795

    Sound level(H/M/L)

    dB(A) 32/28/24 34/29/26 37/32/29 39/35/31 42/40/38 45/43/41 45/43/41 46/44/42 48/45/42

    External staticpressure

    Pa 0

    Liquid pipe mm(in) 6.35(1/4) 9.52(3/8)

    Gas pipe mm(in) 9.52(3/8) 12.7(1/2) 15.88(5/8) 19.05(3/4)

    Drain pipe mm(in) 20.5(4/5)

  • 8/13/2019 CA-MDS-BHC

    22/30

    Page 22

    Featuring Leading-edge Digital Technology

    McQuay Multi Digital Scroll High Temperature Series

    Autodehumidication

    Auto failuredetection

    Taking in outdoorfresh air

    Air ow modulation Silence mode Anti-mildew lter Timed on/off Auto restart afterpower failure

    (optional)

    Leak-proofdrain pan

    Wireless remote(optional)

    High Static Pressure Duct MDB Series Indoor Units

    The design of McQuay High static pressure duct MDB series indoor units

    takes into account the space module, small partition and other features ofmodern commercial buildings. Cooled/heated air is supplied to all parts of the

    room evenly, causing no indoor temperature difference. The units also timely

    rell the room with fresh air, thus completely eliminating air conditioning related

    harm. Whats more, the air conditioner and air duct are concealed and match

    well with the indoor upholstery, thus saving space and facilitating installation.

    Features

    Unique design

    The unique design makes the pipes easy to connect. Since

    the ange of the air outlet is tightly arranged in the bottom, the

    Gas pipes can be easily installed in the ceiling. It makes the

    mounting less demanding in terms of room height and reduces

    the construction cost.

    Taking in fresh air

    The unit uses an anti-mildew lter, and takes in enough fresh air

    to meet health requirements.

    Graceful installation

    Similar to large central air conditioners, the indoor units and air

    duct are installed inside the ceiling. When the indoor units are

    installed, you can only see the air outlets. Therefore, they match

    well with the indoor upholstery and add more grace to your room.

    Super thin

    The indoor unit is as thin as 350 mm, and is easy to mount on

    the ceiling. In this way, it saves space and building

    Graceful installation

    The unit is ceiling mounted and matches well with the indoor

    upholstery. High static pressure also ensures that conditioned air

    can be supplied over a long distance.

    Comfortable air supply

    The unit supplies cooled (heated) air to all parts of the room. The

    air outlet can be either downward or sideways. The air ow is

    both even and comfortable.

    Bottom air supply

    Side air supply

  • 8/13/2019 CA-MDS-BHC

    23/30

    Page 23

    High static prssure duct indoor units

    Notes:

    1) All specication are subjected to change by the manufacturer without prior notice.

    2) Nominal cooling capacity is based on 27DB, 19WB indoor temp. and 35DB outdoor temp.

    3) Sound level are measured in an 11.5dBA background sound level anechoic chamber.

    Model MDB050T MDB060T MDB080T MDB100T

    Nominal cooling capacitykW 12.5 1.4 2.24 2.8

    Btu/h 42690 47810 76451 95563

    Power supply V/Ph/Hz 220 - 240 / 1 / 50 380 - 415 / 3 / 50

    Rated power input kW 0.615 0.789 1.700 1.480

    Unit dimension (WxDxH) mm 1230910350 1430910350 1690879420 16901020520

    Air ow (H/M/L)

    m3/h 2550/2040/1650 3000/2540/1920 4200/3740/3000 5000

    CFM 1501/1201/971 1766/1495/1130 2470/2211/1769 2940

    Sound level (H/M/L) dB(A) 48/46/44 50/48/46 57/55/52 57

    External static pressure Pa 100 150

    Air outlet dimension mm 286998 2861198 264912 295749

    Air inlet dimension mm 302957 3021157 3881400 4711402

    Net weight kg 69 75 100 150

    Liquid pipe mm(in) 9.52(3/8) 12.7(1/2)

    Gas pipe mm(in) 19.05(3/4) 28.6(1-1/8)

    Drain pipe mm(in) 20.5(4/5)

  • 8/13/2019 CA-MDS-BHC

    24/30

  • 8/13/2019 CA-MDS-BHC

    25/30

    Page 25

    Ceiling mounted and oor standing indoor units

    Notes:

    1) All specication are subjected to change by the manufacturer without prior notice.

    2) Nominal cooling capacity is based on 27DB, 19WB indoor temp. and 35DB outdoor temp.

    3) Sound level are measured in an 11.5dBA background sound level anechoic chamber.

    Model MCM020T MCM030T MCM050T

    Nominal cooling capacitykW 5.8 7.5 12.5

    Btu/h 19810 25610 42690

    Power supply V/Ph/Hz 220 - 240 / 1 / 50

    Rated power input kW 0.081 0.116 0.161

    Net weight kg 39 44 64

    Unit dimension (WxDxH) mm 1214670214 1214670249 1714670249

    Air ow (H/M/L)m3/h 1100/970/750 1300/1100/870 1850/1550/1200

    CFM 647/571/441 765/647/512 1089/912/706

    Sound level (H/M/L) dB(A) 48/45/42 50/46/43 52/48/44

    External static pressure Pa 0

    Liquid pipe mm(in) 9.52(3/8)

    Gas pipe mm(in) 15.88(5/8) 15.88(5/8) 19.05(3/4)

    Drain pipe mm(in) 20.5(4/5)

  • 8/13/2019 CA-MDS-BHC

    26/30

  • 8/13/2019 CA-MDS-BHC

    27/30

    Page 27

    Wall mounted indoor units

    Notes:

    1) All specication are subjected to change by the manufacturer without prior notice.

    2) Nominal cooling capacity is based on 27DB, 19WB indoor temp. and 35DB outdoor temp.

    3) Sound level are measured in an 11.5dBA background sound level anechoic chamber.

    Model MWM008T MWM010T MWM015T MWM020T MCM025T

    Nominal cooling capacitykW 2.2 2.78 3.52 5.4 6.5

    Btu/h 7510 9490 12020 18440 22200

    Power supply V/Ph/Hz 220 - 240 / 1 / 50

    Rated power input kW 0.024 0.036 0.040 0.048 0.068

    Net weight kg 10 12 12 16 16

    Unit dimension (WxDxH) mm 799198260 899198260 1062222304

    Air ow (H/M/L)m3/h 460/330/270 510/420/320 590/500/370 860/720/590 1100/790/680

    CFM 271/194/159 300/247/188 347/294/218 506424/347 647465/400

    Sound level (H/M/L) dB(A) 39/34/28 39/34/28 42/36/29 44/40/35 49/43/40

    External static pressure Pa 0

    Liquid pipe mm(in) 6.35(1/4) 6.35(1/4) 6.35(1/4) 6.35(1/4) 9.52(3/8)

    Gas pipe mm(in) 9.52(3/8) 9.52(3/8) 12.7(1/2) 15.88(5/8) 15.88(5/8)

    Drain pipe mm 16.5 20.5

  • 8/13/2019 CA-MDS-BHC

    28/30

    Page 28

    Featuring Leading-edge Digital Technology

    McQuay Multi Digital Scroll High Temperature Series

    Outdoor Unit Specifcations

    8HP-14HP 16HP-28HP

    Notes:

    1) All specication are subjected to change by the manufacturer without prior notice.

    2) (1)Cooling condition: Indoor D/W bulb Temp. 27/19,outdoor temperature: D bulb Temp.35;

    3) (2)Cooling condition: Indoor D/W bulb Temp. 27/19,outdoor temperature: D bulb Temp.46;

    4) The sound levels above are obtained in a semi-anechoic room with a background sound of 11.5dB(A). Depending on ambient sound or other factors, the actual sound levelmay vary.

    Model MDS080BHC MDS100BHC MDS120BHC MDS140BHC MDS160BHC MDS180BHC MDS200BHC

    Nominal cooling capacity (1)kW 22.4 28.0 33.6 39.2 44.8 50.4 56.0

    Btu/h 76500 95600 114700 133800 152900 172000 191200

    Nominal cooling capacity (2)kW 22.4 26.6 30.4 35.6 41.5 44.8 51.5

    Btu/h 76500 90800 103800 121500 141600 152900 175800

    Rated power input(1) kW 6.4 8.5 9.6 11.9 12.8 14.6 17.2

    Rated power input(2) kW 9.0 10.2 11.8 14.4 16.2 18.2 21.5

    Power supply V/Ph/Hz 380 - 415 / 3 / 50

    Air ow (High/Low)m3/h 11000/5800 12500/7300 12000/6400 13500/8000 22000/11600 22000/11600 25000/14600

    CFM 6474/3414 7357/4297 7063/3767 7946/4709 12949/6828 12949/6828 14715/8593

    Sound level(High/Low) dB(A) 60/54 62/55 61/56 63/57 60/55 60/55 64/58

    Net weight kg 280 285 320 355 515 520 560

    Dimension(WxDxH) mm 9908401840 12908401840 19908401840

    Liquid pipe mm(in) 12.7(1/2) 15.88(5/8) 19.05(3/4)

    Gas pipe mm(in) 28.6(1-1/8) 34.9(1-3/8) 38.1(1-1/2)

    Liquid pipe connection type Flare

    Gas pipe connection type Brazed ange

    Refrigerant type R22

    Max. indoor quantity 13 16 20 24

    Model MDS220BHC MDS240BHC MDS260BHC MDS280BHC

    CombinationMDS120BMHC+MDS100BSHC

    MDS140BMHC+MDS100BSHC

    MDS120BMHC+MDS140BSHC

    MDS140BMHC+MDS140BSHC

    Nominal cooling capacity (1)kW 61.6 67.2 72.8 78.4

    Btu/h 210300 229400 248500 267600

    Nominal cooling capacity (2)kW 57.0 62.2 66.0 71.2

    Btu/h 194500 212300 225300 243000

    Rated power input(1) kW 18.1 20.4 21.5 23.8

    Rated power input(2) kW 22.0 24.6 26.2 28.8

    Power supply V/Ph/Hz 380 - 415 / 3 / 50

    Air ow (High/Low))m3/h 24500/13700 26000/15300 25500/14400 27000/16000

    CFM 14420/8064 15303/9005 15009/8476 15892/9417

    Sound level(High/Low) dB(A) 63/57 64/58 64/58 65/59

    Net weight kg 605 640 675 710

    Dimension(WxDxH) mm 22908401840 25908401840

    Liquid pipe mm(in) 19.05(3/4)

    Gas pipe mm(in) 38.1(1-1/2) 41.3(1-5/8)

    Liquid pipe connection type Flare

    Gas pipe connection type Brazed ange

    Refrigerant type R22

    Max. indoor quantity 24 32

  • 8/13/2019 CA-MDS-BHC

    29/30

    Page 29

    Type Model Name Picture Units Remark

    Electronic

    expansion valve

    box

    MEXMCC, MCK, MCM,

    MWM indoor unitsStandard

    Wireless Remote

    controllerG4

    MCM, MCK, MWM

    indoor unitsStandard

    Wired controller MC301MCC, MDB indoor

    unitsStandard

    Remote controller AC5300Working with the

    wired controllerOptional

    Central controller MC-CCS02B All Optional

    Refnet joint MDS-Yl All Optional

    Refnet joint

    (with insulation)MDS-YI-A All Optional

    Twisted-pair NA All Optional

    Central control

    softwareMC-CCS01A All Optional

    Accessories

    Note:

    There are two types of refnet joint, Y-typeandC-type. We strongly recommend that the customer select

    the refnet joint provided by the factory. If other brands refnet joint is selected, it may result in bad effects to

    the system.

  • 8/13/2019 CA-MDS-BHC

    30/30

    2008 McQuay International +1 (800) 432-1342 www.mcquay.com

    While utmost care is taken in ensuring that all details in the publication are correct at the time of going

    to press, we are constantly striving for improvement and therefore reserve the right to alter model

    specications and equipment without notice.

    Details of specications and equipment are also subject to change to suit local conditions and requirements

    Literature No.: CA-MDS(BHC)-0812A

    Supersedes: Nothing

    Part No.: M08039130008