2
C1-D Enclosed Drives FOR COMMERCIAL PUMP AND FAN CONTROL DURABLE ‘Bullet Proof’ Mitsubishi D700 VFD NEMA 1 UL-1 construction 200 kA Fused Disconnect Switch Class 20 Thermal Overload Relay* DC Link Reactor is standard FLEXIBLE Choice of Bypass or Non Bypass Fully programmable PID control Accepts any analog input signal 3 skip frequencies Can handle long motor cables – up to 1600 feet ADVANCED Full Motor Windmill protection Energy Optimization software – long motor life “Regen Avoid” feature – avoids nuisance tripping for high inertia loads * Bypass controllers

C1 d enclosed drive sell sheet

Embed Size (px)

DESCRIPTION

 

Citation preview

C1-D Enclosed Drives F O R C O M M E R C I A L P U M P

A N D F A N C O N T R O L

DURABLE• ‘BulletProof’MitsubishiD700VFD

• NEMA1UL-1construction

• 200kAFusedDisconnectSwitch

• Class20ThermalOverloadRelay*

• DCLinkReactorisstandard

FLEXIBLE• ChoiceofBypassorNonBypass

• FullyprogrammablePIDcontrol

• Acceptsanyanaloginputsignal

• 3skipfrequencies

• Canhandlelongmotorcables–upto1600feet

ADVANCED• FullMotorWindmillprotection

• EnergyOptimizationsoftware–longmotorlife

• “RegenAvoid”feature–avoidsnuisancetrippingforhighinertialoads

*Bypasscontrollers

www.meau.com 847-478-2100

ProgrammableAutomationControllers•ProgrammableLogicControllers•HumanMachineInterfaces•MotionControllers•ServoSystemsVariableFrequencyDrives•Robots•ComputerizedNumericalControls•LowVoltageSwitchgear

500CorporateWoodsParkwayVernonHills,IL60061

Phn:(847)478-2100Fax:(847)478-2253www.MEAU.com | Serving the Americas

Printedwithsoyinks.L-VH-04056•May,2011

Specificationssubjecttochangewithoutnotice.©2011,MitsubishiElectricAutomation,Inc.

Symbol Horsepower Rating

01

02

03

05

07

10

1HP

2HP

3HP

5HP

7.5HP

10HP

Symbol Input Voltage

2 208 - 230V

4 460 - 480V

Symbol

B Bypass Type

N Non-Bypass Type

Symbol

C1-DF NEMA 1, UL-1

Fused Disconnect

C1-DF

Enclosure Type

Bypass Symbol

D DC Link

None No DC Link

DC Link

V

Standard Features

FR-D700VFDwithPWMcontrol&carrierfrequencyupto14.5kHz

VFDparameterunitforkeypadentryanddisplay

EmergencystopcircuitwithprovisionforN/Ccontacts

Internalcontroltransformer

Panelmountedmastercontrolswitchforbypasschangeover*

Conduitknock-outpointsforpowerentryandexit–bottomofenclosure

DClinkreactortoimprovepowerquality

Allinternalwiringisindividuallymarked,numberedandclearlylabelled

5YearVFDwarranty,2yearfullyinclusivewarrantyforwholecontroller

From Power Supply

To Motor

VFD

*Bypasscontrollers

UseyoursmartphoneQRReaderapplicationformoreinformation.