23
Chapter 4 Date 11/04/99, page 1 PROFIBUS Interface Center

C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 1

PROFIBUS InterfaceCenter

Page 2: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 2

PIC

Christy SparksRon Mitchell

Bernd ManglerTom White

Robert FrellerPhone: (423) 461-2576Fax: (423) [email protected]

Page 3: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 3

� Established since October 1994

� Accredited as official DP-Slave Lab since October 1995

� Accredited as official DP-Master Lab since August 1996

� In the meantime: 48 devices tested by the PIC

PIC - history

Page 4: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 4

PIC provides

� Technical Arm of PTO

� ASIC Support & Development Kits

� Seminars

Page 5: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 5

PIC provides

� Brochure “Connection”

� Internet Services

� Conformance Testing

Page 6: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 6

Certification ofCertification ofPROFIBUSPROFIBUS DevicesDevices

PIC certification

Page 7: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 7

� Why certify products?

� Certification ensures conformance with the standard and therefore interoperability

� Certified devices are more and more required by end users to meet their quality standards

� Certification process allows every vendor to benefit from the PROFIBUS experience and knowledge of the test laboratories

� Certification can be used for marketing and advertisement, because the product is marked as “Certified” in the “Electronic Product Guide” (EPG) (CD ROM or Internet)

PIC certification

Page 8: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 8

PIC certification

� How to become a test laboratory?� Candidate establishes environment to perform tests as

described in the related guidelines

� Candidate prepares quality handbook according to the PROFIBUS guideline

� Candidate applies for accreditation at PNO

� Candidate is audited by an independent expert and result is reported to PI advisory board

� Board decides whether the candidate is accredited

� 1st accreditation is valid for 1 year

� Every re-accreditation is valid for 2 years

Page 9: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 9

PIC certification� PROFIBUS Test Laboratories

DPDP--TestTest PAPA--TestTest FMSFMS--TestTest

itm - Institut für Informationstechnik ���� ����Technische Universität MünchenDr. Peter WenzelHaid-und-Neu-Str. 7, D-76131 Karlsruhe, GermanyPhone: + 49 721 9654-800Fax: + 49 721 9654-809

PROFILab ����Consorzio Padova RicercheProf. ClementeCorso Spagna, 12, I-35127 Padova, ItalyPhone: + 39 049 806 1214Fax: + 39 049 870 3255

Siemens AG ���� ����A&D SE E32, Mr. GötzWürzburger Str. 121, D-90766 Fürth, GermanyPhone: + 49 911 750-2002Fax: + 49 911 750-2100

Page 10: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 10

PIC certification� PROFIBUS Test Laboratories

DPDP--TestTest PAPA--TestTest FMSFMS--TestTest

SIEMENS Energy & Automation Inc. ���� (����)PROFIBUS Interface CenterMr. Robert Freller3000 Bill Garland Road, Johnson City, TN, 37601, USAPhone: +1 423 461 2576 Fax: +1 423 461 2103

ifak ����Institut für Automation und Kommunikation e.V.Dr. Thomas BangemannSteinfeldstr. (IGZ), D-39179 Barleben, GermanyPhone: + 49 39203 8100Fax: + 49 39203 81100

WZL der RWTH Aachen ����Lehrstuhl MTQ, Dr. FreudenbergSteinbachstr. 53 B, D-52056 Aachen, GermanyPhone: + 49 241 807412Fax: + 49 241 8888193

Page 11: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 11

PIC certification

• Vendor applies for an ID number from PROFIBUS International (PI)for his device

• Vendor develops the PROFIBUS device and writes a GSD file

Applies for Certification test at any PROFIBUS Test Lab

Test passed ?NO

YES

Vendor receives two test reports and can apply for a certificate via PI

refu

sed

CERTIFICATE

� How to certify a device!

Page 12: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 12

PIC certification

Provide manufacturer declaration to PI and the Certificate will be extended for 3 more years

Changes inHW or FW?

NOYESRe-certification (process, see page 9)

CERTIFICATE

� How long is a certificate valid?

Certificate >3 years?

YES

Page 13: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 13

PIC certification

CertificationPROFIBUS-DP

Test device

GSD fileand ID confirmation

Configuration tool (in case of a master certification)

Device related documentation(schematic, manual, description)

Page 14: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 14

PIC certification

� Hardware testing� line termination according to EN 50170

� bus connection according to EN 50170� 9 pole SUB D connector or� mandatory signals 5V, GND,RxD,TxD

� RS 485 circuit� line level� differential voltage

Page 15: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 15

PIC certification

� Bus transmission� Measure response monitoring time (t WD)

� Measure TSDR (minimum Slave response time)

� Available address space

� Ident number

� Operation in mixed networks

� Data consistency

� Transmission speeds (Baudrate)

Page 16: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 16

PIC certification

Test device

max length

Oscilloscope

Bus MonitorMaster

Page 17: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 17

� Conformance test� Bus interruption on test device

� Short circuit of bus line on test device

� System off/ on at master

� Class 2 master takes control over

� Optional services (sync, freeze)

� Check of user diagnostic functions

� Check of user parameter data

� State transitions (according to EN 50170 - state machine)

PIC certification

Page 18: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 18

Repeater

Test device

max length

Oscilloscope

Bus Monitor

at least 15 slave devices on the Bus

Test System

PIC certification

Page 19: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 19

� Interoperability� Load test

� A. one class 1 master - test device� B. one class 1 master, several slaves - test device� C. two class 1 master, several slaves - test device � D. class 2 master - test device� E. class 2 master and C and D� F. FMS-components and E

� Test with different configuration tools (S7, COM ET 200, Allen Bradley, Synergetic, SST)

� GSD file check

PIC certification

Page 20: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 20

Repeater/OLM

PROFIBUS DP/FMS

class 1 masterclass 1 master class 2 master other master

Test device

PIC certification

Page 21: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 21

PIC certification

� EMC test� it is required that the Test lab receives a test report or

declaration from the vendor for the following tests

� Interference on the supply line IEC 801-4� Interference on the signal line IEC 801-4� Interference immunity against static discharges IEC 801-2

Page 22: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 22

PIC certification

� Tests are recorded with bus monitor and oscilloscope

� Print outs, documentation and test report are stored for each device

� Test labs have to keep the test documents for at least 3 years

� Report is provided to the device manufacturer (CONFIDENTIAL between customer and PIC)

Page 23: C ROFIBUS enter I nterface - Roma Tre University · Chapter 4 Date 11/04/99, page 2 PIC Christy Sparks Ron Mitchell Bernd Mangler Tom White Robert Freller Phone: (423) 461-2576 Fax:

Chapter 4Date 11/04/99, page 23

PIC certification

� How to identify a certified product?� Ask vendor to fax copy of certificate

� Check in the EPG or on web page