Warning: When mounting fixtures, parts provided by Lumascape must be used.. Always check maximum wattage and lamp typebefore relamping. Follow lamp manufacturers instructions for lamp replacement. Failing to follow these instructions will void warranty.
IMPORTANT INSTRUCTIONSFor Installation LS853LED Single Colour Mains Voltage and SELV
MODELS LS853LED-xxxxxxxxxx9277 V 60Hz
LS853LED-xxxxxxxxxx4120 V 60 Hz
LS853LED-xxxxxxxxxx1312 V AC 12-24 V DC
Uplight Luminaire, 20 watt Single Colour LEDIP68 rated
A.C.N. 010 572 773
Do not use power tools to tighten screws. Do not exert downward force on screws while not fully tightened. Do not overtighten screws.
1
Locate Fixtures
Site fixture, in proximity to cabling, in gravel, soil or concrete. Use discretion in locating fixtures as glass can become very hot and may burn.
4
Mount Fixture
Mount fixture such that the top lip of flange is flush with finished floor level, as shown above.
5 Open Fixture
Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.
C1915 2011_10_REV-004Lumascape Lighting Industries ©2011
www.lumascape.com
o75
CAUTION
Ensure gooddrainage soil
Æ 1240mm (9 / ")2 Finishedfloor level
Depth 180mm
3
Supply Connection
Connect junction box (direct burial splice box) to supply conduit as per instructions. For cable only entry connect underwater rated cable in accordance with local wiring rules. Alternatively, if ordered with 1/2"NPT conduit adaptor connect ensuring watertight seal.
LS843Fixture
FinishedFloor Level
SupplyConduit
JunctionBox(Directburial splicebox)
FLUSH LID
256mm (10.08")
RECESSED LID
240mm (9.45")
Warning: The Luminaire should only be used complete with its protective shield (cover)
6
Target Gimbal 1.Rotate gimbal until the Aiming Mark is targeted as desired.
2
Locate and Mount Power Supply
Check power supply is correct type and size for application. Refer to power supply specification.Mount power supply in suitable location.
For SELV Fittings Only
POWER OUTLET
min
30
0m
m
Power Supply Specification
12V AC - 50/60Hz, Magnetic Transformer Only
12-24V DC - Stabilized Ripple Free Supply only
Warning
- The correct power supply must be used in conjunction with the Luxeon LED light sources. This will ensure the maximum life of the LED light source.- This luminaire must only be installed by a licensed electrical worker- When mounting fixtures, parts provided by Lumascape must be used.
LLUURCC USUS
LISTED
INC
.
Lumascape USA Inc.1300 Industrial Rd., Unit #19San Carlos, CA 94070, USAT 1-(650)-595-LUMA(5862)F 1-(650)-595-5820E [email protected] www.lumascape.com
Free Call US & Canada1-866-695-LUMA(5862)
Warning: When mounting fixtures, parts provided by Lumascape must be used.. Always check maximum wattage and lamp typebefore relamping. Follow lamp manufacturers instructions for lamp replacement. Failing to follow these instructions will void warranty.
IMPORTANT INSTRUCTIONSFor Installation LS853LED Single Colour Mains Voltage and SELV
MODELS LS853LED-xxxxxxxxxx9277 V 60Hz
LS853LED-xxxxxxxxxx4120 V 60 Hz
LS853LED-xxxxxxxxxx1312 V AC 12-24 V DC
Uplight Luminaire, 20 watt Single Colour LEDIP68 rated
A.C.N. 010 572 773
C1915 2011_10_REV-004Lumascape Lighting Industries ©2011
www.lumascape.com
o75
7 9 1
2
6
5
3
4
Torque Pattern
Seal Fixture.
Ensure seal and sealing surface is clean. Clean glass if necessary. Incrementally tighten lid screws using the 3mm Allen key supplied. Lumascape recommends tightening in the above Torque Pattern to 2.5 - 3 N.m.. DO NOT OVER TIGHTEN.
Warning: The Luminaire should only be used complete with its protective shield (cover)
Target Gimbal 2.Adjust gimbal tilt angle by rotating Tilt Adjust screw with Allen key supplied.Approximate angle can be read from the Tilt Angle Indicator.
o20 o20
o40
Warning
- The correct power supply must be used in conjunction with the Luxeon LED light sources. This will ensure the maximum life of the LED light source.- This luminaire must only be installed by a licensed electrical worker- When mounting fixtures, parts provided by Lumascape must be used.
LLUURCC USUS
LISTED
RunFixture
Replaceaccessoriesandallowfixturetoburnfor10-15minutestoallowanymoistureinfixturetoevaporate.
10-15MIN.
60
30
45
8
IMPORTANT INSTRUCTIONS
For Installation LS6052-KMODELS LS640 / LS6052-K
Mounting accessory for LS853LED
Brass Collar.
Stainless Steel Sleeve.
Bolts to anchor sleeve andarrest movement of collar inconcrete.
Styrofoam plug, (Use ifrequired. Ensure removalafter for drainage)
CAUTION; Do not pinch orcut cable beneath sleeve
Finished Floor Level tobe flush with top surfaceof brass collar.
Connector, Submersibleplug and cable. Ensure freecable reaches beyond heightof collar for fixture connection.
GENERAL ASSEMBLY
FIT LS8533LED FIXTURE When ready to install fixture;
- Destroy Foam plug.
- Assemble fixture according to LS853LED Instruction sheet.
- Remove cover plate (if located).
- Join Quick Connectors (do not dispose of cap).
5 6
1. Insert fixture body aligningholes.
2. Use screw to insert/align seal
3. Insert lid and start only,1 screw.
4. Insert screw oppositeand tighten
5. Insert and tighten allscrews.
Do not over tighten.Ensure seal/sealing surfaceis free from debris.
LID TIGHTENINGPROCEDURE
- Pour concrete. Check the topsurface of mounting collar is flushwith the finished floor level.
POUR CONCRETE
4
3
FIT SLEEVE, COLLARAND COVER PLATE
- Fit sleeve over foam plug.Ensure enough cable is in thecavity to connect to fixture.
- Position top lip of mountingcollar to be flush with finishedfloor level.
- Screw cover plate, (Availableseparately, consult yourLumascape dealer), tomounting collar if required.
2
SUPPLY CONNECTION
- Position splice box directlybeneath concrete sleeve andconnect to supply conduit.
- Punch a hole in foam plug largeenough for the connector topass through
- Pack hole in plug around thecable to ensure concretedoesn't enter the fixture cavity.
(Ensure the cap on theconnector is secure)
Layout fixture locations as required.
Use discretion in placement, fixturemay become hot and could burn.
Fixture cavity should be as above.Ensure gravel or similar mediumforms the bottom of cavity toallow drainage.
HOLE DETAIL -SECTION VIEW
1
430M
M(1
’ 5“)
MIN
FINISHEDFLOORLEVEL
GRAVEL
HOLE265MM
(10 / “)1
2
CAUTION - This Product Must Only Be Installed/fitted By A Licensed Electrical WorkerNOTE - As per 2002 NEC Section 300.50, the STOOW cord must be at least 450mm (18in)below a minimum 2 inch thick concrete slab
C1615US - 2006_07_REV001
Factory supplied directburial splice box,epoxy sealed entry. Ensurelid and gasket are replaced.Use 3M brand product#4442 Re-Enterable Gelafter connections havebeen made to ensurewater-proofing.Refer Lumascapeinstructionsheet "For Installation ofLS640/LS6052-K DirectBurial Splice Box” forconnection information. Cable length 900mm (36in)
LURC US
COVERPLATE
MOUNTINGCOLLAR
STAINLESSSTEELSLEEVE
FINISHEDFLOORLEVEL
CONCRETE
FINISHEDFLOORLEVEL
LS853LEDFIXTURE
CONNECTOR
FOAMPLUG
CABLE/DIRECTBURIALSPLICE BOXASSEMBLY
SUPPLYCONDUIT
FOAMPLUG
FINISHEDFLOORLEVEL
SPLICEBOX
PAGE 1
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
DEPTH 240mm
Ensure gooddrainage soil
IMPORTANT INSTRUCTIONS
For Installation LS640
5 64
321
Layout fixture locations asrequired.
Use discretion in placement,fixture may become hot andcould burn.
Fixture cavity requirements areas shown above.
FINISHEDFLOORLEVEL
CAVITY240MM
(9 / )1
2"
DE
PT
H
CAVITY REQUIREMENTS
TILE
GRATE
DECKING
Mount collar securely asrequired in floor media.
MOUNT COLLAR
If installation of fixture intomounting collar is to be delayedwe recommend the installation ofa cover plate. These are availablefrom Lumascape, please consultyour dealer,
TEMPORARY COVER PLATE
SUPPLY CONNECTION
Insert fixture into mounting collaralligning holes in the flange withtapped holes in the collar
MOUNT FIXTURE LAMP, TEST, SEAL.
Complete installation of fixture by inserting lamp, testing and sealing, (As per Instruction6 over.) according to the LS853LED installation instruction sheet.
CAUTION - This Product Must Only Be Installed/fitted By A Licensed Electrical Worker
LURC US
If fixture is ordered with directburial splice box cable entry,connect according to directburial splice box installationinstructions and local wiringrules.
Alternatively, if supplied with1/2"NPT adaptor connect inaccordance with local wiringrules and ensure a watertightseal.
US Head Office
Telephone
Fax
1300 Industrial Rd., Unit #19San Carlos, CA 94070
USA
1-(650)-595-LUMA(5862)
1-(650)-595-5820
Free Call
www.lumascape.com
(US & Canada)
1-866-695-LUMA(5862)
LUMASCAPE USA INC.
IN
C.
SUPPLYCONDUIT
DIRECTBURIALSPLICEBOX
FINISHEDFLOORLEVEL
FIXTURE
MODELS LS640 / LS6052-KMounting accessory for LS853LED
C1615US - 2006_07_REV001
PAGE 2
www.lumascape.com
IMPORTANT INSTRUCTIONS
For Adjusting/Aiming of Refractor LensMODELS LS343-22 * ** ** XT ** * * Wide (VN,MH)
LS343-22 * ** ** XP ** * * Ultra wide (VN,MH)LS343-22 * ** ** XQ ** * * Very Narrow (VN,MH)LS343-22 * ** ** XL ** * * (W, CFL)
C898US - 2006_07_REV001
IMPORTANT
Ensure that glare shieldis
fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.
, ifsupplied - VN models only,
For Very Narrow Refractors -
GlareShield
RefractorSpacer
Lens
Reflector
SecondaryGlass
3
Carefully remove lens (andsecondary glass, glareshield) and tighten grubscrew. Apply gentledownward pressure toblack spacer ring as screwis tightened.
Lock reflector
4
Replace lens (andsecondary glass, glareshield) and outer coverassembly and resealfixture.
Replace lens and lid
Note
Additional filters, (137mm)can be added to the fixtureby retaining beneath springclips on the top of thesecondary glass holder.
Additional filter
1
Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.Loosen grub screw.Replace components.
Open fixture and Unlock
UW & VNMetal HalideOnly
VN Only
2
Turn fixture on. Rotateblack spacer ring and lensuntil required result isachieved. Turn fixture off.
Aim fixture optics
IMPORTANT INSTRUCTIONS
For Adjusting/Aiming of Refractor Lens
C898US - 2006_07_REV001
IMPORTANT
Ensure that glare shieldis
fitted the correct way up asshown. Glare shield shouldseat neatly into fixture.
, ifsupplied - VN models only,
For Very Narrow Refractors -
GlareShield
RefractorSpacer
Lens
Reflector
SecondaryGlass
3
Carefully remove lens (andsecondary glass, glareshield) and tighten grubscrew. Apply gentledownward pressure toblack spacer ring as screwis tightened.
Lock reflector
4
Replace lens (andsecondary glass, glareshield) and outer coverassembly and resealfixture.
Replace lens and lid
Note
Additional filters, (137mm)can be added to the fixtureby retaining beneath springclips on the top of thesecondary glass holder.
Additional filter
1
Loosen screws with allenkey provided. If necessarygently lever lid out withlarge screwdriver. Removecomponents as shown.Loosen grub screw.Replace components.
Open fixture and Unlock
UW & VNMetal HalideOnly
VN Only
2
Turn fixture on. Rotateblack spacer ring and lensuntil required result isachieved. Turn fixture off.
Aim fixture optics
www.lumascape.com
MODELS LS343-22 * ** ** XT ** * * Wide (VN,MH)LS343-22 * ** ** XP ** * * Ultra wide (VN,MH)LS343-22 * ** ** XQ ** * * Very Narrow (VN,MH)LS343-22 * ** ** XL ** * * (W, CFL)
Free Call:
1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)
Fax: 1-(650)-595-5820
1300 Industrial Rd., Unit #19
San Carlos, CA 94070, USA
LUMASCAPE CONTACT DETAILS
LUMASCAPE USA INC.Free Call:
1-866-695-LUMA(5862)Ph: 1-(650)-595-LUMA(5862)
Fax: 1-(650)-595-5820
1300 Industrial Rd., Unit #19
San Carlos, CA 94070, USA
LUMASCAPE CONTACT DETAILS
LUMASCAPE USA INC.