7
By: Jordan Kreitzman Jack Dres Tasha Hart Raphael Onwuzuruigbo Chantel Matikke

By: Jordan Kreitzman Jack Dres Tasha Hart Raphael Onwuzuruigbo Chantel Matikke

Embed Size (px)

Citation preview

Page 1: By: Jordan Kreitzman Jack Dres Tasha Hart Raphael Onwuzuruigbo Chantel Matikke

By: Jordan KreitzmanJack Dres

Tasha HartRaphael Onwuzuruigbo

Chantel Matikke

Page 2: By: Jordan Kreitzman Jack Dres Tasha Hart Raphael Onwuzuruigbo Chantel Matikke

Generator = complicated. Alternating current design.Four coils are oriented in a circle so that

all of the wire is going in a clockwise fashion.

Connected to the axle of the windmill is the magnet disk which consists of four strong magnets oriented like the coils.

These magnets spin very close to the coils to produce the current.

Page 3: By: Jordan Kreitzman Jack Dres Tasha Hart Raphael Onwuzuruigbo Chantel Matikke

Process: Convert the kinetic energy of air particles to rotational kinetic energy of the blades, which spin magnets to produce a current with electrons that convert electrical energy into light.

Windmill feeds off the energy and the bulb is lit.

Page 4: By: Jordan Kreitzman Jack Dres Tasha Hart Raphael Onwuzuruigbo Chantel Matikke

1. The generator works due to the basic idea of changing magnetic flux.

2. As a magnet comes toward a coil, its magnetic field goes through the coil. The coil produces a current in a certain direction to produce a magnetic field that counteracts the field going through it.

3. As soon as the magnet starts leaving the coil, the coil produces a current in the opposite direction to try and keep the magnetic field strong inside the coil.

4. This produces alternating current.

Page 5: By: Jordan Kreitzman Jack Dres Tasha Hart Raphael Onwuzuruigbo Chantel Matikke

Consider a cylinder of air that hits the fan in a time of one second

V=volume; v=velocity; P=power; m=mass; I=current; KE=kinetic energy

1. V=πr²h (since air is traveling at 7m/s, height=7m)

2. m=ρV; ρ(air)=1.2 kg/m³3. KE=.5mv²4. Electrical Aspect: P=IV;

1. V= π(.2667m) ²(7m)=1.564 m³

2. m=(1.2 kg/m³)(1.564m³)=1.877 kg

3. KE=.5(1.877kg)(7 m/s)²=45.99 J (P=45.99 W (Kinetic energy of air hitting blades per second.))

4. P=(1.5A)(2V)=3.0W Efficiency: 3.0W/45.99W

=about 6.5% (efficiency of starting kinetic energy of air to light and heat energy)

Calculations

Page 6: By: Jordan Kreitzman Jack Dres Tasha Hart Raphael Onwuzuruigbo Chantel Matikke

Wire was not insulated at first, which caused problems with the generator.

Coils were not thick enough, which also caused the generator to fail. After we fixed those problems, it worked perfectly.

Blades were tricky as well: Initially, we couldn’t turn them fast enough.Then, we decided to decrease our blade angle,

blade length, and blade width. Finally, everything worked great!

Page 7: By: Jordan Kreitzman Jack Dres Tasha Hart Raphael Onwuzuruigbo Chantel Matikke

Estimated costs of materials: ~$36

2 PVC pipes-$0.50Plywood-$5.00Blades-$1.00Magnet Wire-$14.008 Magnets-$10.00Cardboard-$0.00Nuts and Bolts-$2.00Styrofoam-$0.50Electrical Tape-$3.00

Windmills have poor efficiency

Blade angle is significantPVC pipe is good for low

frictionOverall, the project was

time consuming yet beneficial.

Link to video: It Really Works