15
VGZ-006 / 20100603 BX26E / Page 1 READ ALL INSTRUCTIONS CARE- FULLY BEFORE STARTING THE INSTALLATION OR OPERATING THE STOVE. FAILURE TO FOLLOw INSTRUCTIONS mAY RESULT IN PROPERTY DAmAGE, BODILY INjURY, OR EVEN DEATH. SAFETY INSTRUCTIONS SAFETY NOTICE: IF THIS STO VE IS NOT PROPERL Y INSTALLED, A HOUSE/BUILDING FIRE mAY RESUL T . FOR Y OUR SAFETY, CONT ACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PERmITS, RESTRICTIONS, AND INSTALLA TION REqUI REmENTS FOR YOUR AREA. READ ALL INSTRUCTIONS CAREFULLY. 1. The installation o this stov e must comply with your local building code rulings. Please observe the clearances to combustibles (see reerence fgures 1 & 2). 2. Do not install this stove in a mobil e home, manufactured home, trailer or tent (NO EXCEPTIONS! per HUD Federal Standard: 24 CFR Ch.XX). 3. V eriy that the stove is properly installed beore fring the stove or the frst time. Ater reading these instruct ions, i you have any doubt about your ability to complete your installation properly, you must ob- tain the services o a proessional licensed installer amiliar with all aspects o sae and correct installation. DO NOT use temporary or makeshi t compromises during installation. 4. I an y parts are missing or deective, please notiy the dealer or manuacturer immedi- atel y. DO NOT OPERATE A STOVE THAT IS MISSING ANY P ARTS!. 5. Do not tamper with combustion air control beyond normal adjustment capacities. 6. Always connect this stove to a chimney and vent to the outside. Never vent to another room or inside a building. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERV - ING ANOTHER APPLIANCE. 7. DO NOT CONNECT a wood burning stove to an aluminum Type B gas vent. This is not sae. Use approved masonry or a UL 103 HT Listed Residential Type and Building Heat- ing Appliance Chimney. Use a 6” diameter chimney or larger, that is high enough to give a good drat. (See specifcs in installati on instructions). 8. Be sure that your chimney is saely con- structed and in good repair. Have the chimney inspected by the fre department or a qualifed inspector. Y our ins urance company should be able to recommend a qualifed inspector. Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971  continued on next page STANDARD BoxwooD STove model BX26E Oners manual (save this anual or uture reerence) NOTE: THIS STOVE IS NoT A UL LISTED STOVE. DO NoT USE THIS STO VE IN A mOBILE HOmE, mANUFACTURED HOmE, TRAILER OR TENT – NO EXCEPTIONS! Tools necessary to coplete the assebly o this product are as ollos: (a) adustable rench (b) fat blade scredriver (c) Phillips scredriver (d) pliers. Tools not included.

Bx26e Wood Burning Stove

Embed Size (px)

Citation preview

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 1/14

VGZ-006 / 20100603 BX26E / Page 1

READ ALL INSTRUCTIONS CARE-FULLY BEFORE STARTING THEINSTALLATION OR OPERATING

THE STOVE. FAILURE TO FOLLOwINSTRUCTIONS mAY RESULT INPROPERTY DAmAGE, BODILYINjURY, OR EVEN DEATH.

SAFETY INSTRUCTIONS 

SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE mAYRESULT. FOR YOUR SAFETY, CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT PERmITS,

RESTRICTIONS, AND INSTALLATION REqUIREmENTS FOR YOUR AREA.

READ ALL INSTRUCTIONS CAREFULLY.

1. The installation o this stove must complywith your local building code rulings. Pleaseobserve the clearances to combustibles (seereerence fgures 1 & 2).

2. Do not install this stove in a mobile home,manufactured home, trailer or tent(NO EXCEPTIONS! per HUD FederalStandard: 24 CFR Ch.XX).

3. Veriy that the stove is properly installed

beore fring the stove or the frst time.Ater reading these instructions, i you haveany doubt about your ability to completeyour installation properly, you must ob-tain the services o a proessional licensedinstaller amiliar with all aspects o saeand correct installation. DO NOT use

temporary or makeshit compromisesduring installation.

4. I any parts are missing or deective, pleasenotiy the dealer or manuacturer immedi-ately. DO NOT OPERATE A STOVE THAT

IS MISSING ANY PARTS!.

5. Do not tamper with combustion air controlbeyond normal adjustment capacities.

6. Always connect this stove to a chimney andvent to the outside. Never vent to another roomor inside a building. DO NOT CONNECTTHIS UNIT TO A CHIMNEY FLUE SERV-ING ANOTHER APPLIANCE.

7. DO NOT CONNECT a wood burning stoveto an aluminum Type B gas vent. This is notsae. Use approved masonry or a UL 103 HTListed Residential Type and Building Heat-ing Appliance Chimney. Use a 6” diameterchimney or larger, that is high enough togive a good drat. (See specifcs in installationinstructions).

8. Be sure that your chimney is saely con-structed and in good repair. Have the chimneyinspected by the fre department or a qualifedinspector. Your insurance company should beable to recommend a qualifed inspector.

Vogelzang International Corporation

400 West 17th Street

Holland, Michigan 49423

www.vogelzang.com

Phone: 1-616-396-1911

Fax: 1-616-396-1971

 continued on next page

STANDARD BoxwooD STovemodel BX26E Oners manual

(save this anual or uture reerence)

NOTE: THIS STOVE ISNoT A UL LISTED STOVE.

DO NoT USE THIS STOVE IN AmOBILE HOmE, mANUFACTURED HOmE,TRAILER OR TENT – NO EXCEPTIONS! 

Tools necessary to coplete the assebly o this product are as ollos: (a) adustable rench

(b) fat blade scredriver (c) Phillips scredriver (d) pliers. Tools not included.

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 2/14Page 2  / BX26E  VGZ-006 / 20100603

especially young children should be alerted tothe hazards rom high surace temperatures.Keep away rom a hot stove to avoid burns orclothing ignition.

17. I small children will be in the same roomas the stove during operation, provide a

sturdy barrier to keep them at a save distancerom the stove.  NEVER LEAVE SMALLCHILDREN UNSUPERVISED when they arein the same room as the stove.

18. Keep stove area clear and ree rom allcombustible materials, gasoline, and otherfammable vapors and liquids.

19. To prevent burns, always wear protectiveclothing, leather hearth gloves and eyeprotection, while tending the re.

20. While in operation, keep the eed door closedand secured at all times except while tendingthe re.

21. Do not overire the stove. Overiring willoccur i the eed door is let open duringoperation. Such actions can result in verydangerous operating conditions.

22. All power cords and electrical appliancesand/or assemblies must be kept outside o theclearance dimensions shown in this manual orcombustible materials.

23. For urther inormation on using your stovesaely, obtain a copy o the National Fire

Protection Association (NFPA) publication,“Using Coal and Wood Stoves Saely” NFPANo. HS-10-1978. The address o the NFPA isBatterymarch Park, Quincy, MA 02269.

NOTE: A PROFESSIONAL, LICENSED HEAT-ING AND COOLING CONTRACTOR SHOULD

BE CONSULTED IF YOU HAVE qUESTIONSREGARDING THE INSTALLATION OF THIS

SOLID FUEL BURNING APPLIANCE.

9. Creosote or soot may build up in the chimneyconnector and chimney and cause a house/ building re. Inspect the chimney connectorand chimney twice monthly during the heatingseason and clean i necessary. (See ChimneyMaintenance, page 10).

10. In the event o a chimney re, turn the aircontrol to closed position, leave the buildingand CALL THE FIRE DEPARTMENT IM-MEDIATELY! Have a clearly understood planon how to handle a chimney re by contactingyour local re authority or inormation onproper procedures in the event o a chimneyre.

11. To prevent injury, do not allow anyone to usethis stove who is unamiliar with the correctoperation o the stove.

12. Do no t ope rate s tove wh ile u nder t he

infuence o drugs or alcohol.13. Ashes should not be allowed to accumulate

higher than the optional grate or slide damper.Dispose o ashes in a metal container with atight tting lid. Keep the closed container ona noncombustible foor or on the ground, wellaway rom all combustible materials. Keep theashes in the closed container until all cindershave thoroughly cooled. The ashes may beburied in the ground or picked up by a reusecollector.

14. The special paints used on your stove maygive o some smoke and an odor whilethey are curing during the rst 12 to 15 res.Additional smoke and odor may be emittedrom the light oils used in construction o there box. This should disappear ater a shortperiod o time and not occur again. Personswith lung conditions or owners o susceptibledomestic pets (such as birds) should takeprudent precautions. Open windows anddoors as needed to clear smoke and/or odor.Paint discoloration will occur i the stove is

overred.15. This stove has a painted surace which

is durable but it will not stand rough handlingor abuse. When installing your stove, use carein handling. Clean with soap and warm waterwhen stove is NOT hot. Do not use any acidsor scouring soap, as these solvents wear anddull the nish.

16. While stove is in operation, all persons,

SAFETY INSTRUCTIONS continued…

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 3/14

VGZ-006 / 20100603 BX26E / Page 3

ASSEmblY INSTRUCTIONS 

  tools required

CAUTION: STOVE IS HEAVY. mAkE SURE YOU

HAVE ADEqUATE HELP AND USE PROPERLIFTING TECHNIqUES wHENEVER mOVING

STOVE.

Reer to diagram and parts lists at back o thismanual.1. Uncrate the stove and remove packing mate-

rials and protective poly bag. (Save exteriorcardboard box or urther assembly.)

2. Remove parts rom inside o stove. Partsinclude: one swing top (#9), two lids (#10), onelid support (#11) one damper collar (#13), oneeed door (#7), one lid liter (#15), one slidedamper (#5), our legs (#1), hardware pack (#16), and S-Hook (#17) rom inside rebox.

materials required

(NOTE: The fooin ites are NOT incuded ith your stoe) 

6. Attach the ront legs to hearth with long stovebolts (B), fat washers (E) and hex nuts (F).

7. Careully lit stove upright and place in desired

1/8” dia. Drill Bit(sheet etal scres)

Scredrivers(blade and Phillips types)

5/16” Nut Driver or Ratchet

ith 5/16” Socet (or 1/4”Hex Nuts)

11 Nut Driver orRatchet ith 11 Socet(or Stove Bolts)

Saety Glasses

Hearth Gloves

Pencil

6 oot Folding Rule or

Tape measureTin Snips

Drill: Hand or Electric

Flooring Protection: 36” x 54”

as specifed (see page 3)

Chiney Connection: 6” blac 

steel (24 ga. in.) straight orelbo (as reuired)

1/2” Sheet metal Scres

Chiney: Existing 6” Lined ma-

sonry Chiney or 6” Inside Dia.

listed Type HT chiney.

Furnace Ceent (anuacturerrecoends Rutland Code 78

or euivalent)

 contined on next page

 NOTICE: Vogelzang International Corp. grants no warranty, stated or implied, or the installation or maintenance

 o yor wood stove and assmes no responsibility o any incidental or conseqential damages.

3. Place fattened carton on foor and careullyturn stove over onto carton.

4. Attach the rear legs to base o stove with

long stove bolts (B),fat washer (E)and hex nut (F).

5. Attach hearth to bottom

o stove with two short

stove bolts (A), wash-

ers (E) and hex nuts (F).

ill. A – Hardware Pack

ill. B – Rear Leg

 Assembly

location (see ollowing instructions or properlylocating stove).

8. Attach damper collarto rear top suraceo stove using shortstove bolts (A) fatwashers (E) and hexnuts (F).

9. Place swing top inposition on top o 

stove. To install,position at approxi-mately 45 dgree an-gle to stove (dashedlines in ill. F) until pins drop into locator holesthen swing into position.

ill. C –

 Hearth

 Assembly

ill. D –

 Front Leg

 Assembly

ill. E – Damper Collar

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 4/14Page 4  / BX26E  VGZ-006 / 20100603

Proper clearances must be maintained or adequateair circulation. Adequate ventilation must be

provided while operating this stove.1. The stove must be placed on solid concrete, sol-

id masonry, or when installed on a combustiblefoor, on a listed foor protector, such as Hy-C orImperial Model UL 4870BK or equivalent witha 0.8 R-actor. The base must extend at least 18”beyond the ront o the hearth, 18” to the sideso the stove, and must extend under the stovepipe i it is elbowed towards a wall (see gure

1 and consult local building codes and reprotection ordinances.)

CAUTION: (FIRE HAzARD) CARPETING AND

OTHER COmBUSTIBLE mATERIAL mUST NOTCOVER THE FLOOR PROTECTOR. THESEmATERIALS mUST REmAIN OUTSIDE OF

COmBUSTIBLE CLEARANCES, SEE FIG. 1- 2.

2. The stove must have its own fue. DO NOTCONNECT THIS UNIT TO A CHImNEYFLUE SERVING OTHER APPLIANCES.

3. Ater observing the clearances to combustiblematerials (igure 1 & 2), locate your loorprotector accordingly (igure 1) and care-ully place the stove in your selected location.Install connector pipe, elbows, and thimble asrequired, utilizing either a recently cleaned andinspected 6” masonry chimney or a 6” i.d. listedchimney. Maximum 64 square inches.

4. Use 6” round black stove pipe, not galvanized

ASSEmblY INSTRUCTIONS continued…

stove pipe. Secure pipe to damper and each sec-tion with three (3) sheet metal screws in eachstove pipe and/or elbow joint to rmly hold thepipe sections together. DO NOT CONNECTTHIS STOVE TO ANY AIR DISTRIBU-TION OR DUCT SYSTEm.

5. Recheck clearances rom the stove,connector stove pipe, and corner clearancesusing the location drawings (gure 1 & 2) andyour local building codes or re protectionordinances.

NOTE: Drywall aced with brick or stone mst be considered a combustible surace.

6. Do Not iNstall this stove iN a mobilehome, maNufactureD home, trailer orteNt – NO EXCEPTIONS! (HUD Federa Standard: 24 CFR Ch.XX) 

7. The clearances provided are minimumdimensions determined by NFPA. Installationo this stove must comply with the latest edi-tion o NFPA 211 or reduced clearances and/oryour local building code rulings. Use whicheverminimum dimensions are LARGEST. 

  Failre to ollow these minimm clear- ance reqirements may reslt in an nsaeinstallation and cold case a fre.

8. This stove is NOT a UL listed stove.

10. Place lid support and two lids in position onswing top (see ill. F).

11. Place the slide drat into position on thehearth. Hold in position with round head stove

ill. F – Swing Top, Lid Spport & Lids (2)

bolt (C) andlarge fat wash-er (D).

12. Low er e eddoor into po-sit ion whilealigning hingepins.

13. Place S-Hook in hole at letront corner o hearth. Note:S-Hook is usedto hang lid lit-er while not inuse.

lOCATINg STOvE 

ill. G– Slide Drat, Door &

S-Hook (lid liter storage) Location

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 5/14

VGZ-006 / 20100603 BX26E / Page 5

 Fig. 2 – Top ViewMinimm Corner Clearances rom

Combstible Sraces

36"

36"

CORNER CLEARANCES

lOCATINg STOvE continued…

COMBUSTIBLE

CONSTRUCTION

PER NFPA 211

FLOOR

PROTECTOR

DASHED LINE SHOWS

HORIZONTAL CHIMNEY

CONNECTOR AND

ADDITIONAL FLOOR

PROTECTION REQUIRED

BACKWALL

48" (TOP VIEW)

36"

18"

18" 18"

38"

36"

70"

18”

SIDEWALL

COMBUSTIBLE

CONSTRUCTION

PER NFPA 211

 Fig. 1 – Minimm Clearance Dimensions rom Combstible Sraces

CAUTION: kEEP FURNISHINGS AND OTHERCOmBUSTIBLE mATERIALS AwAY FORm THE

STOVE.

miNimum clearaNcesto combustible surfaces

un sdw ........................ 36 nun bkw........................ 36 n

un cn W .................... 36 nPp cnn bkw .......... 38 n

Pp cnn cng ............ 18 n

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 6/14Page 6  / BX26E  VGZ-006 / 20100603

CONNECTOR PIPE INSTAllATION 

1. The smooth end o the stovepipe ts over thecast iron damper collar. Secure with three (3)sheet metal screws.

2. Horizontal pipe runs must slope upwardstowards the chimney at least 1/4” per oot o horizontal run.

3. You must have at least 18 inches o clearancebetween any horizontal piping and the ceil-ing.

4. The pipe cannot extend into the chimney fue(gure 3).

5. Secure pipe/elbow sections with three (3) sheetmetal screws at each joint to make the pipingrigid.

6. It is recommended that no more than two (2)90° bends be used in the stovepipe installa-

 Fig. 3 – Stovepipe/Fle Connections

correct WroNG WroNG

tion. The use o more than two 90° bends maydecrease the amount o draw and possiblycause smoke spillage. Where possible, use onlycorrugated (nonadjustable) elbows. Theseprovide a better seal.

7. The connector pipe must not pass through an

attic or roo space, closet, or any concealedspace, or foor, ceiling, wall or combustibleconstruction. A UL 103 HT Listed chimneymust be used rom the rst penetration o ceiling or wall to the chimney cap. Never usesingle wall connector pipe as a chimney - ahouse fre could result.

NOTE: STOVE PIPE IS NOT INClUDED .

TO PURCHASE PIPE, VISIT YOUR LOCALHARDwARE, HOmE OR BUILDING CEN-

TER. SEE “LOCATING STOVE” PAGE 3 FORADDITIONAL SPECIFICATIONS.

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 7/14

VGZ-006 / 20100603 BX26E / Page 7

CHImNEY CONNECTIONS 

The stove must be connected to either a ma-

sonry or manuactured metal chimney built and

tested to the specications listed on the previous

pages.

Chimneys perorm two unctions:

1). As a means o exhausting smoke and fue

gases which are the result o uel combustion.

2). The chimney provides “drat” which allows

oxygen to be continuously introduced into the

appliance, so that proper combustion is possible.

This stove relies on natural drat to operate.

 NOTICE: Always provide a sorce o resh air

into the room where the stove is located. Failre

 to do so may reslt in air starvation o other el 

 brning appliances and the possible development

 o hazardos conditions, fre or death.

Your stove itsel does not create drat. Drat is

provided by the chimney. To achieve proper dratyour chimney must meet the three minimum height

requirements detailed in gures 4–7. A minimum

o 0.05 w.c. (measured in water column) is required

or proper drating to prevent back pung, smoke

spillage, and to maximize perormance. (Gauges to

measure drat are readily available at stove stores

and are economical to rent or purchase.)

Factors such as wind, barometric pressure,

trees, terrain and chimney temperature can have

an adverse eect on the drat. The manuacturer

cannot be held responsible or external actors

leading to less than optimal drating.

Should you have a problem with inadequate

drat, you should contact a licensed heating and

cooling contractor or assistance in solving the

problem.

ImPORTANT Installation Points1. Size chimney fue to stove collar. This stove

requires a 6” diameter fue.

2. Never connect this unit to a chimney serv-

ing another appliance.3. The chimney must meet all minimum

height requirements.

4. Never use a chimney to ventilate a cellar

or basement.

5. Contact your local building authority

or approved methods o installation and any

necessary permits and/or inspections.

mASONRY CHImNEYBeore using an existing masonry chimney,

clean the chimney, inspect the fue liner and make

any repairs needed to be sure it is sae to use. Make

repairs beore attaching the stove. The connec-

tor stove pipe and ttings you will need to con-

nect directly to a masonry chimney are shown in

gure 4.

 Fig. 5 - Chimney Constrction Throgh Attic Space

I the connector stove pipe must go through

a combustible wall beore entering the masonry

chimney, consult a qualied mason or chimney

dealer. The installation must conorm to local

building and re codes and latest edition o NFPA

211.

I there is a cleanout opening in the base o the

chimney, close it tightly.

CHImNEYFLUE

5/8" TILECHImNEYLINER

mASONRYCHImNEY

THImBLE

COLLAR

6˝ ROUND24 ga. BLACkSTOVEPIPE

8˝ mIN.LINER

BELOwENTRY

HOLE

 Fig. 4 - Masonry Chimney Connection

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 8/14Page 8  / BX26E  VGZ-006 / 20100603

 Fig. 6 - Chimney Constrction Throgh Roo 

 Fig. 7 - Chimney Connection to Firebox

Throgh Masonry Wall 

CHImNEY CONNECTIONS continued …

mANUFACTURED CHImNEYREFER TO CHIMNEY AND CHIMNEY

CONNECTOR MAKER’S INSTRUCTIONS FOR

INSTALLATION AND USE.

 contined on next page

Use only 6” diameter listed chimney UL 103

HT. Chimney made to this listing is High Tempera-

ture rated to 2100 degrees Fahrenheit. Use chimney

rom only one manuacturer. Never mix brands.

Careully ollow the chimney manuacturer’s stated

requirements and clearances. Use the chimneymanuacturer’s attic guards, roo supports, fashing

and re stops when passing through a ceiling. Use a

listed thimble when passing through a combustible

wall. Do not use makeshit compromises during

installation.  Never se a single-wall connection

 pipe as a chimney!

When using a pre-existing chimney, have it’s

condition and installation inspected beore using.

Make sure that the chimney meets all o the UL

rating requirements listed above. Be aware that

not all manuactured chimney is o the UL 103

HT type.

NOTE: It is recommended that you contact a li-

censed heating and cooling contractor (consult your

local yellow pages) or chimney installation.

Manuactured chimney with the proper required

UL listing is available rom most home centers,

hardware stores, and HVAC supply stores.

I you have access to the internet, you maywish to view chimney manuacturers’ inorma-

tion on-line. See, www.duravent.com, www.

selkirkinc.com, or www.mtlab.com.

VENTING TO EXISTING FIREPLACEIn some instances, people desire to convert an

existing replace or stove use. Usually, sae con-

nection to an existing masonry chimney requires

more work than using a preabricated chimney.

The existing replace must be closed and sealed at

the damper with high-temperature caulk, ceramic

wool, or urnace cement. Prior to installation, clean

and inspect the existing fue and smoke shel. In-

stallation should be designed so the system can be

dismantled or periodic cleaning and inspection.

Beore conversion, make sure the existing chimney

is structurally sound, the chimney incorporates a

fue liner and make sure it is in good condition.

(A fue liner consists o clay tile that protects the

brickwork o a chimney. I a chimney does not have

a liner, or it is damaged, have it relined by a proes-sional. DO NOT uSE a chimney that is nlined 

 or damaged!) I you have any question regarding

the condition o the chimney, consult a qualied

licensed contractor, qualied engineer, competent

mason, certied Chimney Sweep, or a knowledg-

able inspector. Consult your insurance company i 

you cannot nd a qualied expert.

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 9/14

VGZ-006 / 20100603 BX26E / Page 9

CHImNEY CONNECTIONS continued …

CAUTION: Not all freplaces are suitableor conversion to a ood stove. Chec ith a ualifed expert.

Many preabricated ireplaces are o the

“zero-clearance replace” category. These consist

o multilayered metal construction. They are de-

signed with enough insulation and/or air cooling

on the base, back and sides so they can be saely

installed in direct contact with combustible foors

and walls. Although many preabricated replaces

carry endorsements rom nationally recognized

organizations or use as replaces, they have not

been tested or connection to wood stove heaters.

Connecting a stove to such a device will void the

manuacturer’s warranty.

Steel-lined ireplaces are constructed with

1/4” rebox liner, an air chamber in connectionwith 8” o masonry. These can be saely used with

wood burning stoves. They contain all the essential

components o a replace, rebox, damper, throat,

smoke shel, and smoke chamber. Many look iden-

tical to masonry replaces and should be checked

careully beore connecting a stove to them.

Venting a stove directly into a replace does

not meet code and should not be attempted. (This

constitutes connection to another appliance - the

replace.) Combustion products will be deposited

and build up in the rebox or replace. The stovewarranty will be void with such an installation. Do

not create a hazard in your home by connecting in

this manner.

 Fig. 8 - Fireplace Conversion

FIREPLACE INSTALLATION

Do Not Attept to route chiney con-nector pipe through the throat o a fre-place. Directly connecting the stovepipe into the

existing masonry chimney (gure 12 “Type A”

replace conversion) o the replace is the only ap-

proved method o installation. This is a complicated

and involved process and to insure saety should

only by done by a qualied installer.1. An entry hole must be cut through the masonry

and tile liner with minimal damage to the liner.At least 8” o liner must remain below the entryposition. When locating the stove and stove-pipe, all minimum clearances must be observedrom combustible suraces including mantels,combustible trimwork, ceilings and walls.Positioning the center o the stove pipe entryinto the chimney 24” below the ceiling should

insure proper clearance or a 6” stovepipe.2. Install a metal or re clay (5/8” minimum thick-

ness) thimble. Make sure the thimble is fushwith the inner surace o the chimney liner anddoes not protrude into the fue (see gure 4 onpage 6).

3. Secure the thimble with reractory mortar. Thethimble should be surrounded by 8” o solidunit masonry brickwork or 24” o stone.

4. Install the stovepipe into the thimble as ar aspossible without extending past the fue lining

(see gures 4 on page 6).5. A small airspace (about 1/2”) should remain

between the stovepipe and thimble to allow orexpansion o the pipe. Seal this airspace withhigh-temperature caulking or ceramic wool.

6. Secure and seal the damper in the closed posi-tion using high-temp caulking, ceramic wool,or urnace cement. Also check to see i thechimney has a cleanout. I it does, make sure itis closed and sealed as well. A leaky cleanoutwill greatly reduce drat eciency.

I you have any questions regarding venting

your stove, contact the manuacturer or contact

the National Fire Protection Association (NFPA)

and request a copy o the latest editions o NFPA

Standard 211 and NFPA Standard 908. Their ad-

dress is:

Battery March Park, Quincy, MA 02269.

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 10/14Page 10  / BX26E  VGZ-006 / 20100603

OPERATINg INSTRUCTIONS 

CAUTION: HOUSE FIRE HAzARDS

• DonotstorewooDonfloorprotec-TOR, UNDERNEATH STOVEPIPE OR ANY-

wHERE wITHIN mINImUm CLEARANCES FROmCOmBUSTIBLE SURFACES SPECIFIED FOR

THIS STOVE.

• overfiringmaycauseahousefire.YOU ARE OVER FIRING IF THE STOVE ORCHImNEY CONNECTOR GLOwS RED.

wARNING: EXPLOSION HAzARD

• neverusechemicals,gasoline,gas-OLINE-TYPE LANTERN FUEL, kEROSENE,

CHARCOAL LIGHTER FLUID, OR SImILARFLAmmABLE LIqUIDS TO START OR “FRESH-

EN-UP” A FIRE IN THE STOVE.

• Keep allflammableliquiDs, espe-

CIALLY GASOLINE, OUT OF THE VICINITYOF THE STOVE — wHETHER IN USE OR IN

STORAGE.

OPERATING SAFETY PRECAUTIONS

1. NEVER OVER FIRE THIS STOVE BY BUILD-ING EXCESSIVELY HOT FIRES AS A HOUSE/ 

BUILDING FIRE mAY RESULT. YOU ARE OVERFIRING THE STOVE IF STOVE OR STOVEPIPE

BEGINS TO GLOw OR TURN RED.

2. NEVER BUILD EXTREmELY LARGE FIRES

IN THIS TYPE OF STOVE AS DAmAGE TO THESTOVE OR SmOkE LEAkAGE mAY RESULT.

3. STOVE IS HOT wHILE IN OPERATION. kEEPCHILDREN, CLOTHING, AND FURNITURE AwAY

FROm HOT STOVE. CONTACT mAY CAUSESkIN BURNS. DO NOT TOUCH THE STOVE

AFTER FIRING UNTIL IT HAS COOLED.

4. PROVIDE AIR INTO THE ROOm FOR PROP-

ER COmBUSTION.

5. INSPECT STOVEPIPE EVERY 60 DAYS.

REPLACE ImmEDIATELY IF STOVEPIPE ISRUSTING OR LEAkING SmOkE INTO THE

ROOm.

 contined on next page

This stove is designed to burn

wOOD FUEL ONLY.Hardwood, 18” to 20” should be split and air

dried (seasoned), or 6 months to obtain maximum

burning eciency. Wood should be stored in a dry,

well ventilated area.

NOTICE: USE SOLID wOOD mATERIALS ONLY.

DO NOT BURN GARBAGE OR FLAmmABLEFLUIDS. DO NOT USE COAL AS COAL OR

CHARCOAL wILL DESTROY THE GRATE AND/ OR THE FIREBOX.

NOTE: A 2” layer o sand or a layer o frebric should be used as botto insulation in theBoxood stove. An optional cast iron grate,26G, ay be used instead o frebric or

sand. See Accessory Sheet included iththis anual or ordering inoration.

LIGHTING1. Open drat damper ully to provide maximum

drat.

2. Open the eed door and place several wads o crushed paper in the rebox.

3. Lay small stacks o kindling on the paper tostart the re.

4. Light the paper and kindling, close the door

and secure tightly.5. Add uel ater re is burning briskly. Use care

not to smother the kindling re when addingwood. Close the door and secure tightly.

6. Adjust the drat damper and slide dratcontrol. The more closed the slide drat is set,the lower and slower the re will burn. Themore open, the aster and hotter the re willburn. Do not over re the stove.

ADDING FUEL

Add small amounts o uel each hour or soinstead o piling large quantities o uel at one

time. This will insure a more complete combustion

process and less buildup o tars, soot, or creosote

will occur in the chimney.1. Always open drat damper beore opening the

eed door.

2. When adding uel be careul not to smother there.

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 11/14

VGZ-006 / 20100603 BX26E / Page 11

OPERATINg INSTRUCTIONS continued …

3. Close the eed door and secure tightly.

4. Adjust the damper and slide drat control.

5. Empty ashes regularly. Do not allow ashesto pile up higher than the top lip o the slidedrat.

6. Properly dispose o hot ashes (see Saety

Instructions, item #13 on page 2.)7. Do not over re the stove.

CAUTION: DO NOT OVER FIRE APPLIANCE.

TOO mUCH wOOD OR BURNING NON-RECOmmENDED mATERIALS SUCH ASTRASH OR FLAmmABLE LIqUIDS mAY CAUSE

OVERFIRING. YOU ARE OVER FIRING IF THECHImNEY CONNECTORS OR STOVE GLOwS

RED. CLOSE THE DOOR, SLIDE DRAFT ANDDAmPER ImmEDIATELY TO REDUCE THE AIR

SUPPLY TO THE FIRE. THIS wILL SLOw DOwNTHE FIRE.

CAUTION: SLOw BURNING FIRES AND EX-TENDED USE mAY CAUSE EXCESSIVE CREO-

SOTE BUILDUP. IGNITION OF CREOSOTEBUILDUP OR OVER FIRING mAY CAUSE A

CHImNEY FIRE. CHImNEY FIRES BURN EX-TREmELY HOT AND mAY IGNITE SURROUND-ING mATERIALS. IN CASE OF A CHImNEY FIRE

ImmEDIATELY LEAVE THE BUILDING ANDCALL THE FIRE DEPARTmENT FROm A SAFE

LOCATION.

mAINTENANCE & SERvICE HINTS 

ASH DISPOSAL – Do not allow ashes to

accumulate higher than the slide drat. Dispose o 

properly. (See Saety Instructions #13, page 2.)

CHImNEY DRAFT – Drat is a unction o 

the chimney, not the stove — do not expect the

stove to draw. Smoke spillage into the house or

excessive buildup o condensation or creosote in

the chimney are warnings that the chimney is NOT

unctioning properly. Correct the problem beoreusing the stove. Following are some possible causes

or improper drat.

1. The connector stovepipe may be pushed

into the chimney too ar, stopping the drat.

2. I the chimney temperature is too cool,

water will condense in the chimney and run back 

into the stove. Creosote ormation will be rapid

and may block the chimney. Operate the stove at a

re level high enough to keep the chimney warm

to prevent condensation rom orming.

3. I the re burns well but sometimes createsexcess smoke or burns slowly, it may be caused by

the chimney top being lower than another part o 

the house or a nearby tree. The wind blowing over

a house or tree, alls on top o the chimney like

water over a dam, beating down the smoke. The

top o the chimney should be at least three (3) eet

above the roo and be at least two (2) eet higher

than any point o the roo within ten (10) eet.

CREOSOTE – Foration and Reoval. Slow-burning wood produces tar and other organic

vapors which combine with expelled moisture to

orm creosote. Creosote vapors condense in the

relatively cool chimney fue o a slow-burning re.

As a result, creosote residue accumulates on the fue

lining. I ignited, this creosote creates an extremelyhot re which may ignite surrounding materials

resulting in a building re.

I creosote has accumulated, it should be

removed. Failure to remove creosote may result

in ignition and may cause a house/building re.

Creosote may be removed using a chimney brush

or other commonly available materials rom your

local hardware retailer.

CHImNEY INSPECTIONS – The chimney

connector and chimney should be inspected at thebeginning o and at least twice a month during 

the heating season to determine i a creosote buildup

has occurred.

Chimney res burn very hot. I the chimney

connector should glow red, reduce the re by clos-

ing the damper and spin drat control and immedi-

ately call the re department. contined on next page

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 12/14Page 12  / BX26E  VGZ-006 / 20100603

mAINTENANCE & SERvICE continued …

CAUTION: A CHImNEY FIRE mAY CAUSE IGNI-TION OF wALL STUDS OR RAFTERS wHICH

wERE ASSUmED TO BE A SAFE DISTANCEFROm THE CHImNEY. IF A CHImNEY FIRE

HAS OCCURRED, HAVE YOUR CHImNEY IN-SPECTED BY A qUALIFIED EXPERT BEFORE

USING AGAIN.

A ire in the stove may be smothered by

pouring a large quantity o coarse salt, baking soda,

or cool ashes on top o the re.

STOVE jOINTS – Reuired Tune-up.This stove is manuactured with cast iron

components.   IT DOES NOT HAVE WELDED

SEAMS. Periodic “tune up” may be required by

relling and/or replacing the cement/joint mortar

along the seams where the cast iron components

meet.

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 13/14

VGZ-006 / 20100603 BX26E / Page 13

ORDERINg PARTS - bX26E bOXwOOD STOvE 

When ordering missing or replacement parts, always give the Model Number o the stove, 

Part Number, and Part Description. Use the illustration and parts list provided to identiy parts.

 Part No. Description qty.

1 Leg ............................................................... 4

2 Bottom ......................................................... 1

3 Side ............................................................. 2

4 Back ............................................................. 15 Slide Draft Damper ...................................... 1

6 Front ............................................................ 1

7 Feed Door .................................................... 1

8 Top ............................................................... 1

9 Swing Top .................................................... 1

10 Lid ................................................................ 2

11 Lid Support .................................................. 1

12 Hearth .......................................................... 1

13 Damper Collar Assembly ............................. 1

14 Door Handle Assembly ............................... 1

15 Lid Lifter (L-1) .............................................. 1

16 Hardware Pack, Complete .......................... 1

17 S-Hook (used to hang lid lifter) .................... 1

18 Door Latch ................................................... 1

19 Retainer Bolts .............................................. 4

8/6/2019 Bx26e Wood Burning Stove

http://slidepdf.com/reader/full/bx26e-wood-burning-stove 14/14

This Vogelzang heating appliance is sae when installed properly and will provide you with years o 

service. However, always exercise good judgement when you are using this stove. You are dealing with

FIRE! Fire is inherently dangerous and must be treated with respect. Stay warm and in good health!

Respectully yours,

 Proprietor

Vogelzang International Corporation

400 West 17th Street

Holland, Michigan 49423

www.vogelzang.com

Phone: 1-616-396-1911

Fax: 1-616-396-1971

COmPANY TESTImONY:

“FOR GOD SO LOVED THE wORLD THAT HE GAVE HIS ONLY BEGOTTEN SON, THAT wHOEVER

BELIEVES IN HIm SHALL NOT PERISH BUT HAVE ETERNAL LIFE”

jOHN 3:16

mADE IN CHINA

DO NoT USE THIS STOVE IN AmOBILE HOmE, mANUFACTURED HOmE,TRAILER OR TENT — NO EXCEPTIONS!