Table of Contents Page
Quick Installation Guide - Disconnect Switch Installation 2,3 - Disconnect Handle Installation 3 - Assemble and Install Line Terminal Guard 4 - Cable Mechanism Installation 4 - Connecting Rod Adjustment Procedure 5
Enclosure Without Handle Cutout 6 - Locate Handle - Drill Handle Holes
Door Catch Mounting Bracket Installation 7
Trailer Fuse Block Installation (400A) 8
Phase Barrier Replacement (400A) 9
Fuse Clip Installation (400A) 10
Bulletin 1494C Cable Operated Disconnect Switch Kit Components 11 Bulletin 1494C Cable Operated Disconnect Switch Kit Optional Accessory List 12
ATTENTION: The following procedures are critical to the proper operation of the disconnect handle and switch. Failure to follow these steps can result in damage to the equipment and/or serious injury or death to the operator.
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
G. Ushakow 12-3-0712-3-07
12-3-07
M. JutzJ. Koziczkowski
ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing. Follow NFPA 70E requirements. Install in suitable enclosure. Keep free from contaminants.
Bulletin 1494C Cable Operated Disconnect Switch Kit (400A)Installation Instructions(Cat 1494C- _ _ _ Series 2 : 400A)
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
1 13
1030857
2
QUICK INSTALLATION GUIDE
Disconnect Switch Installation
Enclosure with Right Hand Flange Enclosure with Left Hand Flange
Enclosure with Right Hand Flange Enclosure with Left Hand Flange
(2)
FFMinimum Bend Diameter
16" Dia.
FF
1
IMPORTANT: When locating the 400A switch, verify that the minimum diameter for the loop of the cable between the switch mechanism and handle mechanism is not less than 16 inches.Any reduction to the diameter of the bend loop for the cable will reduce the efficiency of the cable system, and create additional drag and friction within the cable conduit.
IMPORTANT: Verify that the cable assembly does not interfere with any mechanical and moving parts. Keep the cable conduit a minimum of 1/2" from all heat sources and current carrying terminals, fuses, transformers, etc.
FF
FF
FF
AA BB CC DD
EE(4) Mounting Plate Holes
Locate switch with right hand mechanism
SwitchSize
2" 11" 4-3/4" 1-3/8" 9/32" Dia.400A
Panel Mounting Dimensions
1a
Locate switch with left hand mechanism1b
BB
AA
DD
EE
CC
BB
AA
DD
EE
CC
2 13
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC. 10308572
BB
AA
DD
EE
CC
BB
AA
DD
EE
CC
Disconnect Switch with Right Hand Cable Mechanism
(shown)
NOTE: Apply grease from capsule to gasket or grooveto retain gasket to handle.
(3)
Assemble disconnect switch to cable switch mechanism
Install rubber handle on line terminal guard Install the line terminal guard on disconnect switch
Assemble disconnect switch assembly to mounting plate
90 - 130 lb-in (400A)
LINE TERMINAL GUARD
90 - 130 lb-in (400A)
LINE TERMINAL GUARD
Disconnect Switch Installation (Cont'd)
Disconnect Handle Installation
Thread forming screws
provided with cable mechanism.
Thread forming screws provided with disconnect switch.
2
4
Install gasket1 2 3
5
3
2
1
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
3 13
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
7-11 lb-in
Install handle and mechanism bracket Install defeater lever
(Right HandFlange MountedShown)
10308572
60 - 80 lb-in
1
(4)
3
2
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
4 13
Cable Mechanism Installation3Verify that disconnect switch and handle are in "ON" position. (Switch blades will not be visible)
Rotate connecting rod (clockwise) into drive bar until it begins to exit the drive bar (approximately 18 full turns).
Align connecting rod with primary link
ConnectingRod
Primary Link
10308572
(5)
5 6
ATTENTION: CHECK FOR PROPER OPERATION. Upon completion of the installation instructions, no further adjustment of the cable mechanism is required.
5 13
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
Cable Mechanism Installation (Cont'd)3Install hitch pin clip Turn disconnect handle "OFF" and
install handle mechanism spring
Hitch Pin Clip
Connecting Rod Adjustment Procedure4"ON" Position➊ Move disconnect handle to the "ON" position.
➋ If switch does not fully close, return handle to "OFF" position.
➌ Remove link spring hitch pin and disengage the connecting rod from the primary link.
➍ Turn connecting rod counter-clockwise (1 or more) full turns.
➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test
➏ Repeat ➊ - ➎ as necessary.
➐ Re-install link spring.
"OFF" Position➊ Move disconnect handle to the "OFF" position.
➋ If switch does not fully open, return handle to "ON" position.
➌ Remove hitch pin and link spring, then disengage the connecting rod from the primary link.
➍ Turn connecting rod clockwise (1 or more) full turns.
➎ Re-engage connecting rod in primary link of handle, insert hitch pin and re-test.
➏ Repeat ➊ - ➎ as necessary.
➐ Re-install link spring.
10308572
(6)
Enclosure without Handle Cutout
1
Top Handle Hole
Top Handle Hole
Square corners orup to 1/4" radius
Locate Handle
Right Hand Flange Left Hand Flange
(2) .328 Dia. Holes
1/4"
1/2"
Drill Handle Holes2
● Enclosures with a Flange Thickness less than 3/16" use dimensions below to install disconnect handle.
6-1/2"5-1/2"
5/16"
14-3/8" 14-3/8"
1-3/8" 1-3/8"1-1/8" 1-1/8"
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
6 13
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.10308572
(7)
7 13
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
Door Catch Bracket Installation Right hand installation shown (for left hand installation follow similar procedures)
Top Handle Hole
Door CatchMounting
Bracket
Door CatchMountingBracket
Right Hand Flange Left Hand Flange
1 - 1/8"
1 - 3/8"
Enclosure Door Flange Thickness K
1 - 5/8"
Enclosure Base
TOP VIEW
Door Catch Mounting Bracket:● Provided with projections for welding.● Projections can also be used as a guide for drilling holes.● Can be used as a template to drill corresponding holes in the enclosure door. ● User to supply the hardware for fastening the bracket. ● Fasteners must provide the degree of ingress protection for the environmental rating of the enclosure. ● The bracket hardware must be inaccessible to unauthorized personnel.
Dimension K (3/4" to 1")● When using large disconnect handle kit only (1494F-M2 or -S2), use door catch provided with handle kit.● When using large disconnect handle kit and small door hardware kits (1494V-L1, -LL1, -L2 or -LL2), use door catch provided with door hardware kit.
Dimension K (1-1/8" to 1-3/8")● When using large disconnect handle kit and large door hardware kits (1494V-L3 or -LL3), use door catch provided with door hardware kit.
Door CatchMounting Bracket
Door CatchMounting Bracket
Door Catch
Door Catch
Top
10308572
14-3/8"
1-3/8" 1-3/8"1-1/8" 1-1/8"
14-3/8"
3-3/4"
1-5/8"
3-3/4"
1-5/8"
(8)
1494V-FS400
1494V-FS400
Install Trailer Fuse Block2
Trailer Fuse Block Installation (Switch Rating 400A)
1 Trailer Fuse Block Location
400 Amp Trailer Fuse Block (1494V-FS400)Torque (lb-in)Fuse
90-130
90-130
7-11/16"10-3/16"6-3/8"6-3/8"
8-11/16"11-11/16"7-3/16"8-11/16"
200200200200400400400400
250600600600250600600600
H/RH/R
JHRCII-C
H/RH/R
JHRCII-C
16-22 175-200 275-305
22-37 175-200 275-305
Amps Voltage Class FuseBlock
AFuseClip
Lug toTerminal
Wireinto Lug
Note: Refer to the figures and chart below to determine the location on the mounting plate for the trailer fuse block. (Not required for non-fusible disconnect switch applications.)
(See Table )
8 13
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.10308572
A
4 - 3/4"
(9)
4
3
Phase Barrier Replacement Kit (Switch Rating 400A) 1494F-PH5
Terminal Adapter Installation - Conversion from Fusible to Non-Fusible (Switch Rating 400A)
175 - 200 lb-in
20 - 30 lb-in
90 - 110 lb-in
35 - 50 lb-in
CLICK
1
2
31
2
9 13
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC. 10308572
(10)
Fuse Clip Installation (Switch Rating 400A)
1
2
1
2
23 - 37 lb-in40 - 55 lb-in
200A Fuse Clips400A Fuse Clips
Switch for Right Hand Mechanism Switch for Left Hand Mechanism
Switch for Right Hand Mechanism Switch for Left Hand Mechanism
1
2
1
2
2
16 - 22 lb-in22 - 37 lb-in
200A Fuse Clips400A Fuse Clips
16 - 22 lb-in22 - 37 lb-in
200A Fuse Clips400A Fuse Clips
23 - 37 lb-in40 - 55 lb-in
200A Fuse Clips400A Fuse Clips
1
2
1
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
10 13
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.10308572
(11)
Disconnect Switch Kit
Handle
Switch
FuseBlock
FuseClips
Cat No.
Switch for Right Hand Mechanism 1494F-D400 (400A)
Switch for Left Hand Mechanism 1494F-DX400 (400A)
1494F-M2 (7-1/2" Painted Metal) (400A - 600A)1494F-S2 (7-1/2" Stainless Steel) (400A - 600A)
1494V-FS400 (400A)
1401-N45 (Class H,J, 200A - 250V, 200A - 600V)1401-N46 (Class H,J, 400A - 250V, 400A - 600V)1401-N54 (Class R, 200A - 250V, 200A - 600V)1401-N55 (Class R, 400A - 250V, 400A - 600V)
Cable with Right Hand Mechanism1494C-CM9: 400A (4 Ft Cable)1494C-CM10: 400A (5 Ft Cable)1494C-CM11: 400A (6 Ft Cable)1494C-CM12: 400A (10 Ft Cable)
Cable with Left Hand Mechanism1494C-CMX9: 400A (4 Ft Cable)1494C-CMX10: 400A (5 Ft Cable)1494C-CMX11: 400A (6 Ft Cable)1494C-CMX12: 400A (10 Ft Cable)
CableMechanism
Bulletin 1494C Cable Operated Disconnect Switch Kit Components
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
11 13
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.10308572
42052-155-01 (2)Printed in U.S.A.
BULLETIN 1494C (400A) CABLE OPERATED DISCONNECT SWITCH KIT INSTALLATION
INSTRUCTION SHEET
1 1026760
42052-155OF
N/A
N/A
N/A
REVISIONAUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.SIZE
SHEET
B
1 2 3 4 5 6 7 8
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORESURFACE TREATMENT
(DIMENSIONS IN INCHES)TOLERANCES UNLESSOTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
42052
------------- --------------------------
---------------------------------------
12 13
THIS DRAWING IS THE PROPERTY OFROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,USED OR DISCLOSED FOR ANY PURPOSEEXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.10308572
ElectricalInterlock
AuxiliaryContact
AuxiliaryContact
Adapter Kit
Wire LugConnectors
Optional Accessories(Installation Instructions
Not Included)Cat No.
Switch withRight Hand Mechanism 1495-N43 (1-N.O./N.C.) (200A - 400A)1495-N44 (2-N.O./N.C.) (200A - 400A)
Switch withLeft Hand Mechanism 1495-N41 (1-N.O./N.C.) (400A)1495-N42 (2-N.O./N.C.) (400A)
1495-N8 (1-N.O.) (30A - 400A)1495-N9 (1-N.C.) (30A - 400A)
1495-N25 (200A - 400A)(Required only for switch withLeft Hand Mechanism)
FuseCover
with Door
1494R-N14(CU Wire Size (2 ) - #1/0 - 250 MCM (400A) 1494R-N15(CU Wire Size #4.......500 MCM (400A)
Bulletin 1494C Cable Operated Disconnect Switch Kit Optional Accessory List
PhaseBarrier 1494F-PH5 (400A)
SwitchRating
FuseClass
Fuse ClipRating
Cat No.
250V 600V
200A400A
200A400A
200A400A
200A400A
H, J, R400A
---- ----Non-Fusible
1495-N68➀
H, J, R
400A---- ----Non-Fusible
1495-N63➁
➀ Switch with right hand mechanism➁ Switch with left hand mechanism