Building Services Water supply Waste Water system Heating and Production of DHW Chimney Gas supply Gas supply Ventilation Air-conditioning Szikra Csaba

BUILDING SERVICES

Embed Size (px)

DESCRIPTION

LITERATURE

Citation preview

  • Building Services Water supply

    Waste Water system Heating and Production of DHW

    ChimneyGas supply Gas supply Ventilation

    Air-conditioning

    Szikra Csaba

  • Water supplyWaste Water system

  • Water Supply of domestic level

    Main considerations

    1. Valves

    2. Drainage

    3. Section Valves

    4. Equipments4. Equipments

    5. Isolation of equipments

    6. Main metering

    7. Domestic metering

    8. Exhausting of air

    9. Pipe and material

    10.Size of the pipe -1-2

    11.Driving of pipe

  • Pipe materials Copper, Poly ethylene, PVC

  • Pipe materials Composite materials

    Vzellts - Csatornzs

  • Production of Domestic Hot Water byWall mounted boiler with indirectly heated water storage

    Control:

    Temperature sensor

    Switch valve

    Guided for DHW

    production;

    Advantages:

    Smaller necessary heat

    capacity

    Continuously served hot

    Boiler

    Switchvalve

    Bypassvalve

    Heat emiter

    Gzellts

    water with uniform

    temperature

    Suitable for circulating

    network

    Condensation boiler

    technology

    Domestic board sizes:

    Nominal heat

    capacity10 .. 28kW

    Storage capacity: 50 ..

    200l

    Hot water storage

    Temperature sensor

    Heat exchanger

  • Water and DHW Supply of domestic level

  • Water and DHW Supply of domestic level with circulating pipe network

    non return

    valve

    Pump,

  • Domestic water metering

    Length [mm] 130Size [coll]

    a [mm]: 70

    pletenergetikai s pletgpszeti Tanszk1111 Budapest, Megyetem rkp. 3.

    a [mm]: 70b [mm]: 130c [mm]: 230d [mm]: 53e [mm] 17,5Sly [kg]: 0,5

  • Waste Water SystemFloor sink

    Cast iron drainage grate (old fashion type)

    Generally for rooms where escaped water arises (shower, industrial kitchen, etc.)

    Main problem is the solution of an adequate joint with the building construction (water proofing)

    Suez type trap Floor sink with inbuilt trap Connection for one or two Connection for one or two additional equipment connection (hand wash or shower)

    Modern floor sinks: Floor sink with inbuilt trap Connection for additional equipment(s)

    Horizontal or vertical outlet connection

    Inbuilt check valve (against back flush )

    DN40, DN50 inlet size Adjustable stainless steel cover (elevation range 12 90mm)

    Minium space demand 12cm Equipped with water proofing flange

  • Sink: mixing tap for cold and hot water

    auxiliary vent (2 pieces) DN50 sewage pipe connection Construction

    single double triple basins with or without drip plate Cast Iron, Ceramic, drawn-shell

    case steel sheet with enamel covering, Stainless steel

    Wall mounted basin:

    Waste Water SystemKitchen

    Wall mounted basin: single tap wit cold and hot water

    auxiliary vent (2 pieces) DN50 sewage pipe connection Construction:

    Cast Iron, Ceramic, drawn-shell case steel sheet with enamel covering, Stainless steel

    threaded connection for flexible pipe

    equipped with air inlet valve

    Trap for washing and washing-up machine

    auxiliary vent DN40 sewage pipe connection Equipped with air inlet valve

  • Bath and shower:

    mixing tap for cold and hot

    water

    auxiliary vent (2 pieces)

    DN50 sewage pipe connection

    Construction:

    Cast Iron, Ceramic, drawn-shell

    case steel sheet with enamel

    covering, Stainless steel

    Waste Water SystemBathroom

    With inbuilt trap or connection

    to the floor sink

    Inbuilt

    Hand wash

    mixing tap for cold and hot

    water

    auxiliary vent (2 pieces)

    DN40 sewage pipe connection

    Construction:

    Porcelain

    Inbuilt

  • Waste Water SystemEquipments Lavatory

    Toilet:

    Types:

    Horizontal or vertical outlet

    Hi-flush or low-flush .

    Overhanging or standing

    Flush tank: inbuilt, wall mounted,

    Connections:

    DN100 sewage pipe.

    3/8 cold water.

    Construction: Construction:

    Porcelain.

    Bidet:

    Connections:

    DN40 sewage pipe.

    1/2 cold and hot water with mixing tap

    Pissuire:

    Connections:

    DN40 sewage pipe.

    1/2 cold water, with manual and controlled

    valve 600

  • Sewage Pipe NetworkParts of the inner pipe network:

  • Pipe materials PVC, Hard Poly Ethilen with bell connections

  • Heating Production of Domestic Hot Water

    Chimney

  • Chimney

    Different systems:Class a. : Open combustion chamber (no chimney)

    The supplied air from the indoor environment The burning product is driven to the indoor

    environment

    Class b. : Atmospheric systemThe supplied air from the indoor environment The supplied air from the indoor environment

    The burning product is driven out from the indoor environment by a chimney

    Closed Air Circuit

    Class c. : Closed system The supplied air from the outdoor environment The burning product is driven out from the

    indoor environment by a chimney There is no connection of the indoor

    environment a the the burning area

  • Individual Chimney Stack

    Chimney

    Equipment

    Spoil draught

  • Supplementary Chimney Stack

    Individual chimney

    ChimneySupplementarystack(shunt)Spoil draught

    Equipment

  • U-duct Chimney System

    h

    Flue gas (smoke)Air

    Equipment

  • Heating and production of DHW with wall mounted boiler Closed System

    Airfor combustion

    Flue gas(smoke)

    Equipment

  • Chimney for Closed Systems 1

  • Chimney for Closed Systems 2

    pletenergetikai s pletgpszeti Tanszk1111 Budapest, Megyetem rkp. 3.

  • Chimney Materials

    Built chimneys: Brick Body with of without insulation Stainless steel or aluminum inner pipe

    Constructed chimneysAluminum external pipe coveringAluminum external pipe covering

    Insulation (rock wool) Stainless steel inner pipe

    Other materials: Schamotte

  • 24kW Net heat

    Levels Inner pipe diameter (exetral size)

    1 equipment by floor 2 equipments by floor

    1 14 (36x36) 18 (40x40)2 16 (36x36) 22 (48x48)

    Chimney for Closed Systems size

    2 16 (36x36) 22 (48x48)3 18 (40x40) 25 (48x48)

    4 20 (40x40) 30 (55x55)

    5 22 (48x48)

    pletenergetikai s pletgpszeti Tanszk1111 Budapest, Megyetem rkp. 3.

  • Water and DHW Supply of domestic level with circulating pipe network and chimney

  • Space demand:

    Single Meter

    Interconnecting pipe

    always from left

    Service connection

    always from right

    Closing valve in both

    side above 6m3/h

    Gas MetersRules of Placement of meters in domestic level

    Interconnecting pipe

    network:

    Service

    connection

    2

    0

    0 Interconnecting pipe

    network:

    1

    2

    0

    0

    side above 6m /h

    Ventilatable,

    lockable cabinet

    Multi Meter place

    Water jacket

    Nominal size in

    domestic level

    G4,G6 (m3/h)

    Size: 302410 (cm)

    Connection:1 1,

    25cm

    500

    6

    0

    0

    2

    5

    0

    1

    2

    0

    0

    .

    .

    1

    7

    0

    0

    9

    0

    0

    1

    6

    0

    0

    2

    5

    0

    1000

    1

    2

    0

    0

  • Gas SupplyGas distribution system Domestic pipe network

    Interconnecting pipe

    Service connections

    ChimneyBoylerKitchen stove

    Esta

    te b o

    r der

    2

    0

    0

    1

    6

    0

    0

    7

    0

    0

    Gas meter

    0,00

    steel1"

    steel1"

    1

    1

    0

    0

    1

    2

    0

    0

  • Small domestic Ventilation systems

    Requirements: Toilet: 50m3/h Bathroom: 100m3/h Kitchen: 200m3/h Other: Minimum ACH = 0.5

    System:System: Local wall mounted exhaust fan Local Kitchen Equipment Natural ventilation

    Duct Diameter:

    100 300, max air velocity velocity 4-6m/s

  • Small domestic Ventilation systems

    Wall mounted, centrifugal fans. This types of fan is often applied in exhaust ventilation of bathrooms and toilets. There is a small fan installed in each rooms which required ventilation.

    In each wall mounted fan there is In each wall mounted fan there is an back draught shutter to avoid unnecessary back circulation from other rooms.

  • Small domestic Ventilation systems

  • As it was seen in local exhaust and inlet ventilation also there is only one duct for the incoming or leaving air. The only different is in stead of applying local fans one bigger size fan serving the ventilated areas.

    This ventilation system schema is mostly applied in exhaust ventilation system of multilevel buildings. The fan is installed in the main duct or at the end of the duct as a roof fan.

    Heat recovery system can not be applied, and also the

    Ventilation and Air Handling

    Central ventilation Exhaust system

    Heat recovery system can not be applied, and also the demand control can not be achieved easily, so this system is not energy efficient.

    Application of this system is advantageous where there is no heat requirement and continuous operation is required

    If demand control is required, there is possible to install motor controlled shuttle valve, which closes the airflow when there is no need for ventilation. In this case the electric motor of the fan has frequency converter, so the volume flow rate is adjustable.

    Department of Building Energetics and ServicesH 1111 Budapest, Megyetem rkp. 3.

  • Ventilation and Air Handling

    Central ventilation Exhaust system

    Duct material:

    Steel (~1mm)

    Size:

    100 125 160 200 250 314 mm

    Where to place: Shaft

    Necessary diameter [4 m/s air speed]

    100 100m3/h

    125 150m3/h

    pletenergetikai s pletgpszeti Tanszk1111 Budapest, Megyetem rkp. 3.

    125 150m3/h

    160 250m3/h

    200 400m3/h

    250 700m3/h

    315 1200m3/h

  • Roof fan: These types of fans are mounted at the end of the duct on masonry wall or on external metal frame. There two types of roof fans according to the direction of the ejecting air: horizontal and vertical Considering acoustic point of view, the vertical type is better, because the radiated noise distribution is higher at the top of the instrument.

    Ventilation and Air Handling

    Fans

    Duct fans: For smaller pressure head there is an

    Department of Building Energetics and Services

    H 1111 Budapest, Megyetem rkp. 3.

    Duct fans: For smaller pressure head there is an axial bladed, for higher there are pressure head radial bladed. Axial bladed fans mostly are applied in smaller systems. Because of in bigger system needs bigger pressure, so in higher system always better o apply redial bladed fans. For smaller systems better to apply duct fan because there is no need for separated room for the ventilation. Disadvantages of the duct fans are the noise level, which emitted to the fans environment. Duct fan is suitable for exhaust, inlet and also for balanced ventilation system.

  • Ventilation and Air Handling

    Central ventilation system

    Air handling unit

    Inlet air

    outlet air

    Ventilated area

    Fresh air Exhaust air

    In central ventilation system the incoming and the exhausting air join in one common area, which is always an air handling unit. For the air handling unit there are separated ducts, which are

    Fresh air duct, with an air intake inlet at the external area,

    Exhaust duct, with an ejection outlet also in the external area,

    Inlet duct for serving the handled air to the ventilated area,

    Outlet duct for the removal and delivering to the air handling unit of the used air.

    One important aim of the air handling unit is to recover the energy content from the exhaust air to the fresh air.

    Department of Building Energetics and ServicesH 1111 Budapest, Megyetem rkp. 3.

  • In balanced ventilation system there is no pressure different in-between the ventilated area and its surroundings.

    In this case for the incoming and also for the exhausting air there are separated duct with inbuilt fan.

    With balanced ventilation system all the other services can be handled.

    Ventilation and Air Handling

    Air distribution

    FanExhaust air

    FanInlet air

    the other services can be handled.

    Also with a small modification of the incoming and exhausting air volume, this can be achieved by adjusting element, depressive and compressive ventilation system can be operated.

    Department of Building Energetics and Services

    H 1111 Budapest, Megyetem rkp. 3.

    Fan