Building Services Water supply
Waste Water system Heating and Production of DHW
ChimneyGas supply Gas supply Ventilation
Air-conditioning
Szikra Csaba
Water supplyWaste Water system
Water Supply of domestic level
Main considerations
1. Valves
2. Drainage
3. Section Valves
4. Equipments4. Equipments
5. Isolation of equipments
6. Main metering
7. Domestic metering
8. Exhausting of air
9. Pipe and material
10.Size of the pipe -1-2
11.Driving of pipe
Pipe materials Copper, Poly ethylene, PVC
Pipe materials Composite materials
Vzellts - Csatornzs
Production of Domestic Hot Water byWall mounted boiler with indirectly heated water storage
Control:
Temperature sensor
Switch valve
Guided for DHW
production;
Advantages:
Smaller necessary heat
capacity
Continuously served hot
Boiler
Switchvalve
Bypassvalve
Heat emiter
Gzellts
water with uniform
temperature
Suitable for circulating
network
Condensation boiler
technology
Domestic board sizes:
Nominal heat
capacity10 .. 28kW
Storage capacity: 50 ..
200l
Hot water storage
Temperature sensor
Heat exchanger
Water and DHW Supply of domestic level
Water and DHW Supply of domestic level with circulating pipe network
non return
valve
Pump,
Domestic water metering
Length [mm] 130Size [coll]
a [mm]: 70
pletenergetikai s pletgpszeti Tanszk1111 Budapest, Megyetem rkp. 3.
a [mm]: 70b [mm]: 130c [mm]: 230d [mm]: 53e [mm] 17,5Sly [kg]: 0,5
Waste Water SystemFloor sink
Cast iron drainage grate (old fashion type)
Generally for rooms where escaped water arises (shower, industrial kitchen, etc.)
Main problem is the solution of an adequate joint with the building construction (water proofing)
Suez type trap Floor sink with inbuilt trap Connection for one or two Connection for one or two additional equipment connection (hand wash or shower)
Modern floor sinks: Floor sink with inbuilt trap Connection for additional equipment(s)
Horizontal or vertical outlet connection
Inbuilt check valve (against back flush )
DN40, DN50 inlet size Adjustable stainless steel cover (elevation range 12 90mm)
Minium space demand 12cm Equipped with water proofing flange
Sink: mixing tap for cold and hot water
auxiliary vent (2 pieces) DN50 sewage pipe connection Construction
single double triple basins with or without drip plate Cast Iron, Ceramic, drawn-shell
case steel sheet with enamel covering, Stainless steel
Wall mounted basin:
Waste Water SystemKitchen
Wall mounted basin: single tap wit cold and hot water
auxiliary vent (2 pieces) DN50 sewage pipe connection Construction:
Cast Iron, Ceramic, drawn-shell case steel sheet with enamel covering, Stainless steel
threaded connection for flexible pipe
equipped with air inlet valve
Trap for washing and washing-up machine
auxiliary vent DN40 sewage pipe connection Equipped with air inlet valve
Bath and shower:
mixing tap for cold and hot
water
auxiliary vent (2 pieces)
DN50 sewage pipe connection
Construction:
Cast Iron, Ceramic, drawn-shell
case steel sheet with enamel
covering, Stainless steel
Waste Water SystemBathroom
With inbuilt trap or connection
to the floor sink
Inbuilt
Hand wash
mixing tap for cold and hot
water
auxiliary vent (2 pieces)
DN40 sewage pipe connection
Construction:
Porcelain
Inbuilt
Waste Water SystemEquipments Lavatory
Toilet:
Types:
Horizontal or vertical outlet
Hi-flush or low-flush .
Overhanging or standing
Flush tank: inbuilt, wall mounted,
Connections:
DN100 sewage pipe.
3/8 cold water.
Construction: Construction:
Porcelain.
Bidet:
Connections:
DN40 sewage pipe.
1/2 cold and hot water with mixing tap
Pissuire:
Connections:
DN40 sewage pipe.
1/2 cold water, with manual and controlled
valve 600
Sewage Pipe NetworkParts of the inner pipe network:
Pipe materials PVC, Hard Poly Ethilen with bell connections
Heating Production of Domestic Hot Water
Chimney
Chimney
Different systems:Class a. : Open combustion chamber (no chimney)
The supplied air from the indoor environment The burning product is driven to the indoor
environment
Class b. : Atmospheric systemThe supplied air from the indoor environment The supplied air from the indoor environment
The burning product is driven out from the indoor environment by a chimney
Closed Air Circuit
Class c. : Closed system The supplied air from the outdoor environment The burning product is driven out from the
indoor environment by a chimney There is no connection of the indoor
environment a the the burning area
Individual Chimney Stack
Chimney
Equipment
Spoil draught
Supplementary Chimney Stack
Individual chimney
ChimneySupplementarystack(shunt)Spoil draught
Equipment
U-duct Chimney System
h
Flue gas (smoke)Air
Equipment
Heating and production of DHW with wall mounted boiler Closed System
Airfor combustion
Flue gas(smoke)
Equipment
Chimney for Closed Systems 1
Chimney for Closed Systems 2
pletenergetikai s pletgpszeti Tanszk1111 Budapest, Megyetem rkp. 3.
Chimney Materials
Built chimneys: Brick Body with of without insulation Stainless steel or aluminum inner pipe
Constructed chimneysAluminum external pipe coveringAluminum external pipe covering
Insulation (rock wool) Stainless steel inner pipe
Other materials: Schamotte
24kW Net heat
Levels Inner pipe diameter (exetral size)
1 equipment by floor 2 equipments by floor
1 14 (36x36) 18 (40x40)2 16 (36x36) 22 (48x48)
Chimney for Closed Systems size
2 16 (36x36) 22 (48x48)3 18 (40x40) 25 (48x48)
4 20 (40x40) 30 (55x55)
5 22 (48x48)
pletenergetikai s pletgpszeti Tanszk1111 Budapest, Megyetem rkp. 3.
Water and DHW Supply of domestic level with circulating pipe network and chimney
Space demand:
Single Meter
Interconnecting pipe
always from left
Service connection
always from right
Closing valve in both
side above 6m3/h
Gas MetersRules of Placement of meters in domestic level
Interconnecting pipe
network:
Service
connection
2
0
0 Interconnecting pipe
network:
1
2
0
0
side above 6m /h
Ventilatable,
lockable cabinet
Multi Meter place
Water jacket
Nominal size in
domestic level
G4,G6 (m3/h)
Size: 302410 (cm)
Connection:1 1,
25cm
500
6
0
0
2
5
0
1
2
0
0
.
.
1
7
0
0
9
0
0
1
6
0
0
2
5
0
1000
1
2
0
0
Gas SupplyGas distribution system Domestic pipe network
Interconnecting pipe
Service connections
ChimneyBoylerKitchen stove
Esta
te b o
r der
2
0
0
1
6
0
0
7
0
0
Gas meter
0,00
steel1"
steel1"
1
1
0
0
1
2
0
0
Small domestic Ventilation systems
Requirements: Toilet: 50m3/h Bathroom: 100m3/h Kitchen: 200m3/h Other: Minimum ACH = 0.5
System:System: Local wall mounted exhaust fan Local Kitchen Equipment Natural ventilation
Duct Diameter:
100 300, max air velocity velocity 4-6m/s
Small domestic Ventilation systems
Wall mounted, centrifugal fans. This types of fan is often applied in exhaust ventilation of bathrooms and toilets. There is a small fan installed in each rooms which required ventilation.
In each wall mounted fan there is In each wall mounted fan there is an back draught shutter to avoid unnecessary back circulation from other rooms.
Small domestic Ventilation systems
As it was seen in local exhaust and inlet ventilation also there is only one duct for the incoming or leaving air. The only different is in stead of applying local fans one bigger size fan serving the ventilated areas.
This ventilation system schema is mostly applied in exhaust ventilation system of multilevel buildings. The fan is installed in the main duct or at the end of the duct as a roof fan.
Heat recovery system can not be applied, and also the
Ventilation and Air Handling
Central ventilation Exhaust system
Heat recovery system can not be applied, and also the demand control can not be achieved easily, so this system is not energy efficient.
Application of this system is advantageous where there is no heat requirement and continuous operation is required
If demand control is required, there is possible to install motor controlled shuttle valve, which closes the airflow when there is no need for ventilation. In this case the electric motor of the fan has frequency converter, so the volume flow rate is adjustable.
Department of Building Energetics and ServicesH 1111 Budapest, Megyetem rkp. 3.
Ventilation and Air Handling
Central ventilation Exhaust system
Duct material:
Steel (~1mm)
Size:
100 125 160 200 250 314 mm
Where to place: Shaft
Necessary diameter [4 m/s air speed]
100 100m3/h
125 150m3/h
pletenergetikai s pletgpszeti Tanszk1111 Budapest, Megyetem rkp. 3.
125 150m3/h
160 250m3/h
200 400m3/h
250 700m3/h
315 1200m3/h
Roof fan: These types of fans are mounted at the end of the duct on masonry wall or on external metal frame. There two types of roof fans according to the direction of the ejecting air: horizontal and vertical Considering acoustic point of view, the vertical type is better, because the radiated noise distribution is higher at the top of the instrument.
Ventilation and Air Handling
Fans
Duct fans: For smaller pressure head there is an
Department of Building Energetics and Services
H 1111 Budapest, Megyetem rkp. 3.
Duct fans: For smaller pressure head there is an axial bladed, for higher there are pressure head radial bladed. Axial bladed fans mostly are applied in smaller systems. Because of in bigger system needs bigger pressure, so in higher system always better o apply redial bladed fans. For smaller systems better to apply duct fan because there is no need for separated room for the ventilation. Disadvantages of the duct fans are the noise level, which emitted to the fans environment. Duct fan is suitable for exhaust, inlet and also for balanced ventilation system.
Ventilation and Air Handling
Central ventilation system
Air handling unit
Inlet air
outlet air
Ventilated area
Fresh air Exhaust air
In central ventilation system the incoming and the exhausting air join in one common area, which is always an air handling unit. For the air handling unit there are separated ducts, which are
Fresh air duct, with an air intake inlet at the external area,
Exhaust duct, with an ejection outlet also in the external area,
Inlet duct for serving the handled air to the ventilated area,
Outlet duct for the removal and delivering to the air handling unit of the used air.
One important aim of the air handling unit is to recover the energy content from the exhaust air to the fresh air.
Department of Building Energetics and ServicesH 1111 Budapest, Megyetem rkp. 3.
In balanced ventilation system there is no pressure different in-between the ventilated area and its surroundings.
In this case for the incoming and also for the exhausting air there are separated duct with inbuilt fan.
With balanced ventilation system all the other services can be handled.
Ventilation and Air Handling
Air distribution
FanExhaust air
FanInlet air
the other services can be handled.
Also with a small modification of the incoming and exhausting air volume, this can be achieved by adjusting element, depressive and compressive ventilation system can be operated.
Department of Building Energetics and Services
H 1111 Budapest, Megyetem rkp. 3.
Fan