12

BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family
Page 2: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family

www.absa.net.au

NatHERS Rated7.6/10 STARS**www.nathers.gov.au

BUILDING ENERGY EFFICIENCY CERTIFICATE

DONALD CLEAVER - EVAN STEELEISSUED TO

LOT 162 SPRINGVIEW DRIVEADDRESS

Site Lot LOT 162

MOUNT GAMBIER

SA

5291

1011190012CERTIFICATION NUMBER

17/06/2017DATE

61CLIMATE ZONE

FirstRate5 - v 5.2.4a (FirstRate5)SOFTWARE

80.4 MJ/m2 paSIMULATED ENERGY CONSUMPTION - HEATING

2.9 MJ/m2 paSIMULATED ENERGY CONSUMPTION -COOLING

83.3 MJ/m2 paTOTAL SIMULATED ENERGY CONSUMPTION

173.8 m2

FLOOR AREA - CONDITIONED

31.2 m2

FLOOR AREA - UNCONDITIONED

205.0 m2

FLOOR AREA - TOTAL

Jeremy VaughanASSESSOR NAME

50018ASSESSOR NUMBER

JM & ML Vaughan Pty LtdCOMPANY

ASSESSOR SIGNATURE Issued by a BUILDING THERMAL PERFORMANCEASSESSOR accredited by the Australian BuildingSustainability Association to provide NatHERShouse energy ratings.

This certificate is not for regulatory purposes and is for use by the homeowner only. The house energy rating has been based on information provided at the time of rating. Modifications made to the design or onsite substitution of materials may effect the rating.ABSA-Version 1.2 -July 2014© All rights reserved

Page 3: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family

Assessor details

Accreditationnumber: 50018Name: JEREMY VAUGHANOrganisation: JM & ML Vaughan pty ltdEmail: [email protected]: 0407600353Declarationof interest: Employed by designer of the buildingSoftware: FirstRate5: 5.2.5 (3.13)AAO: ABSA

Overview

Dwelling details

Address: LOT 162 SPRINGVIEW DRIVESuburb: MOUNT GAMBIERState: SA Postcode: 5290Type: New Home NCC Class: Class 1aLot/DPnumber: -

NatHERSclimate zone: 61

Exposure: open

7.6The more stars the more

energy efficient

Predicted annual energy load for heating and coolingbased on standard occupancy assumptions

83.3 MJ/m2

For more information onyour dwelling's rating see:

www.nathers.gov.au

Key construction and insulation materials(see following pages for details)

Construction: Wall: BRICK VENEERRoof: COLORBOND CUSTOM ORBFloor: CONCRETE SLAB ON GROUND

Insulation: Wall: R2.7 BATTS & SISLRoof: R5.0 BATTS & R1.0 SISLFloor: NIL

Glazing: PVC & ALUMINIUMDOUBLE GLAZED

Ceiling penetrations(see following pages fordetails)

Sealed: 43Unsealed: 0TOTAL:** 43

**NOTE: This total is the maximumnumber of ceiling penetrations allowedto a ceiling (under a roof) for thiscertificate. If this number is excededin construction then this certificateIS NOT VALID and a new certificateis required. Loss of ceiling insulationfor the penetrations listed has beentaken into account with the rating.

Principal downlight type: No downlights modelled

Net floor area (m2)

Conditioned: 173.8Unconditioned: 31.2Garage: 39.6TOTAL: 244.6

Annual thermalperformance loads(MJ/m2)

Heating: 80.4Cooling: 2.9TOTAL: 83.3

Plan documents

Plan ref/date: 16_196Prepared by: R.DOMASCHENZ

Window selection -default windows onlyNote on allowable window values: Only a5% tolerance to the nominated SHGCwindow values shown on page 2 can beused with this rating.

Note: Only a +/-5% SHGCtolerance is allowed with thisrating.NB: This tolerance ONLY applies toSHGC, the U-value can always be lowerbut not higher than the values stated onpage 2.If any of the windows selected areoutside the 5% tolerance then thiscertificate is no longer valid and thedwelling will need to be rerated toconfirm compliance.

Scan to access thiscertificate online andconfirm this is valid.

https://www.fr5.com.au/QRCodeLanding?PublicId=W66T893KCK

Nationwide House Energy Rating Scheme* Certificate

Certificate Number: W66T893KCK Date of Certificate: 17 Jun 2017 ★ Star rating: 7.6

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territorygovernments. For more details see www.nathers.gov.au

Page 1 of 6

Page 4: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family

Windows type and performance value

Window ID Window type U-value SHGC

PVC-006-01 W uPVC B DG Argon Fill Clear-Clear 2.6 0.53

ALM-002-01 A Aluminium B SG Clear 6.7 0.7

ALM-006-03 A Aluminium B DG Argon Fill High Solar Gain low-E -Clear 4.1 0.52

Windows schedule

Window ID Window no. Height (mm) Width (mm) Orientation Zone name Outdoor shade

PVC-006-01 W Opening 16 1200 1800 WSW Study No

PVC-006-01 W Opening 33 600 1800 NNW Study No

ALM-002-01 A Opening 4 600 1500 SSE Garage No

ALM-006-03 A Opening 5 1500 1500 SSE Bed 2 No

ALM-002-01 A Opening 6 900 600 SSE Ldry No

ALM-002-01 A Opening 7 900 900 SSE WC No

PVC-006-01 W Opening 8 1500 1500 SSE Bath No

PVC-006-01 W Opening 9 2100 2100 ENE Bed 1 No

ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No

ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No

PVC-006-01 W Opening 12 2100 2100 NNW Family Din Kit No

PVC-006-01 W Opening 13 2100 2100 NNW Family Din Kit No

PVC-006-01 W Opening 14 2100 2100 NNW Family Din Kit No

PVC-006-01 W Opening 15 2100 600 WSW Family Din Kit No

Roof windows and skylight type and performance value

ID Window type U-value SHGC

Roof window and skylight schedule

ID Roof window/ skylight no. Area (m2) Orientation Zone nameOutdoorshade

Indoor shade/diffuser

External wall type

Type Insulation Wall wrap

1 : FR5 - Brick Veneer Glass fibre batt: R2.5 (R2.5) Yes

External wall schedule

Nationwide House Energy Rating Scheme* Certificate

Certificate Number: W66T893KCK Date of Certificate: 17 Jun 2017 ★ Star rating: 7.6

Building Features

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territorygovernments. For more details see www.nathers.gov.au

Page 2 of 6

Page 5: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family

Wall type Area (m2) Orientation Zone name Fixed shade Eaves

1 : FR5 - Brick Veneer 8.3 WSW Study No Yes

1 : FR5 - Brick Veneer 5 SSE Study Yes No

1 : FR5 - Brick Veneer 11.5 NNW Study Yes Yes

1 : FR5 - Brick Veneer 3.8 WSW Entry a/l Yes Yes

1 : FR5 - Brick Veneer 15.1 WSW Garage No Yes

1 : FR5 - Brick Veneer 15.1 SSE Garage No Yes

1 : FR5 - Brick Veneer 4.4 NNW Garage Yes No

1 : FR5 - Brick Veneer 7.9 SSE Bed 2 No Yes

1 : FR5 - Brick Veneer 4.5 SSE Ldry No Yes

1 : FR5 - Brick Veneer 3.9 SSE WC No Yes

1 : FR5 - Brick Veneer 6.9 SSE Bath No Yes

1 : FR5 - Brick Veneer 9.6 SSE B1 WIR No Yes

1 : FR5 - Brick Veneer 4.7 ENE B1 WIR No Yes

1 : FR5 - Brick Veneer 11.5 ENE Bed 1 No Yes

1 : FR5 - Brick Veneer 13.8 ENE Alfresco No Yes

1 : FR5 - Brick Veneer 9.6 NNW Alfresco No Yes

1 : FR5 - Brick Veneer 28.3 NNW Family Din Kit No Yes

1 : FR5 - Brick Veneer 2.9 WSW Family Din Kit Yes Yes

Internal wall type

Type Area (m2) Insulation

1 : FR5 - Internal Plasterboard Stud Wall 381.2 Glass fibre batt: R2.5 (R2.5)

Floors

Location Construction Area (m2) Sub floor ventilation Added insulation Covering

Study CSOG: Slab on Ground 16.7 Enclosed 0.0 Carpet

Entry a/l CSOG: Slab on Ground 4.3 Enclosed 0.0 Tiles

Garage CSOG: Slab on Ground 39.6 Enclosed 0.0 none

Bed 2 CSOG: Slab on Ground 13.5 Enclosed 0.0 Carpet

WIR CSOG: Slab on Ground 2.2 Enclosed 0.0 Carpet

Ldry CSOG: Slab on Ground 7.7 Enclosed 0.0 Tiles

WC CSOG: Slab on Ground 1.5 Enclosed 0.0 Tiles

Vanity CSOG: Slab on Ground 5.6 Enclosed 0.0 Tiles

Nationwide House Energy Rating Scheme* Certificate

Certificate Number: W66T893KCK Date of Certificate: 17 Jun 2017 ★ Star rating: 7.6

Building Features

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territorygovernments. For more details see www.nathers.gov.au

Page 3 of 6

Page 6: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family

Bath CSOG: Slab on Ground 10.8 Enclosed 0.0 Tiles

Passage CSOG: Slab on Ground 7.4 Enclosed 0.0 Carpet

B1 WIR CSOG: Slab on Ground 7.8 Enclosed 0.0 Carpet

Bed 1 CSOG: Slab on Ground 19.1 Enclosed 0.0 Carpet

Alfresco CSOG: Slab on Ground 23.1 Enclosed 0.0 floattimber

Ptry CSOG: Slab on Ground 6.9 Enclosed 0.0 floattimber

Family Din Kit CSOG: Slab on Ground 78.4 Enclosed 0.0 floattimber

Ceiling type

Location Material Added insulation Roof space above

Study Plasterboard 5.0 Yes

Entry a/l Plasterboard 5.0 Yes

Garage Plasterboard 5.0 Yes

Bed 2 Plasterboard 5.0 Yes

WIR Plasterboard 5.0 Yes

Ldry Plasterboard 5.0 Yes

WC Plasterboard 5.0 Yes

Vanity Plasterboard 5.0 Yes

Bath Plasterboard 5.0 Yes

Passage Plasterboard 5.0 Yes

B1 WIR Plasterboard 5.0 Yes

Bed 1 Plasterboard 5.0 Yes

Alfresco Plasterboard 5.0 Yes

Ptry Plasterboard 5.0 Yes

Family Din Kit Plasterboard 5.0 Yes

Ceiling penetrations

Location Number Type Width (mm) Length (mm) Seal/ unsealed

Study 2 Downlights 90 90 Sealed

Entry a/l 1 Downlights 90 90 Sealed

Garage 2 Downlights 90 90 Sealed

Bed 2 1 Downlights 90 90 Sealed

WIR 2 Downlights 90 90 Sealed

Ldry 1 Downlights 90 90 Sealed

WC 1 Downlights 90 90 Sealed

Nationwide House Energy Rating Scheme* Certificate

Certificate Number: W66T893KCK Date of Certificate: 17 Jun 2017 ★ Star rating: 7.6

Building Features

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territorygovernments. For more details see www.nathers.gov.au

Page 4 of 6

Page 7: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family

Vanity 3 Downlights 90 90 Sealed

Bath 2 Downlights 90 90 Sealed

Passage 2 Downlights 90 90 Sealed

B1 WIR 2 Exhaust Fans 90 90 Sealed

Bed 1 2 Downlights 90 90 Sealed

Alfresco 4 Downlights 90 90 Sealed

Ptry 2 Downlights 90 90 Sealed

Family Din Kit 16 Downlights 90 90 Sealed

Ceiling fans

Location Number Diameter (mm)

Roof type

Material Added insulation Roof colour

Cont:Attic-Continuous 1.0 medium

Nationwide House Energy Rating Scheme* Certificate

Certificate Number: W66T893KCK Date of Certificate: 17 Jun 2017 ★ Star rating: 7.6

Building Features

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territorygovernments. For more details see www.nathers.gov.au

Page 5 of 6

Page 8: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family

Additional information

CLEAR ALUMINIUM & PVC WINDOWS ADOPTED THROUGHOUT AS NOTED ON PLANS AS PER OWNERSINSTRUCTIONS

REVISED 17.06.17 TO INCLUDE NEW STUDY WINDOW

Explanatory notes

About this report

Residential energy ratings address the quality of thebuilding fabric i.e. walls, windows, floors and roof/ceilings.Ratings do not cover the energy or water efficiency ofappliances including heating and cooling, hot water,dishwashers, ovens, fridges, TVs etc. or solar panel orwater tank requirements. The efficiency or specification ofthese items is generally covered by other regulations,standards or guidelines.

General Information

A NatHERS House Energy Rating is a comprehensive,dynamic computer modelling evaluation of the floorplans,elevations and specifications to predict an energy load ofa home. Not all of us use our homes in the same way, soratings are generated using standard assumptions. Thismeans homes can be compared across the country.The actual energy consumption of your home may varysignificantly from the predicted energy load figures in thisreport depending on issues such as the size of yourhousehold and your personal preferences, e.g. in terms ofheating or cooling.While the figures are an indicative guide to energy use,they can be used as a reliable guide for comparativepurposes between different house designs and fordemonstrating that the design meets the requiredregulatory compliance.Homes that are energy efficient use less energy, arewarmer in winter, cooler in summer and cost less to run.The higher the star rating the more energy efficient.This NatHERS House Energy Rating report was carefullyprepared by your assessor on the basis of comprehensivemodelling using standard procedures to rate your homeusing an underlying engine developed by the AustralianCommonwealth Scientific and Industrial ResearchOrganisation (CSIRO).All information relating to energy loads presented in thisreport is based on a range of standard assumptions inorder to allow for comparisons with reports prepared forother homes and to demonstrate minimum regulatorycompliance. The standard assumptions include figures foroccupancy, indoor air temperature and are based on aunique climate file for your region.

Accredited Assessors

To ensure you get a high-quality, professional NatHERSHouse Energy Rating report, you should always use anaccredited assessor, accredited assessors are membersof a professional body called an Assessor AccreditingOrganisation (AAO).AAOs have specific quality assurance processes in placeand continuing professional development requirements tomaintain a high and consistent standard of assessmentsacross the country. Non-accredited assessors do not havethis level of quality assurance or any on-going trainingrequirements.If you have any questions or concerns about this report,please direct them to your assessor in the first instance.If your assessor is unable to address your questions orconcerns, please contact their AAO listed under ‘assessordetails’. You can also find a range of information aboutaccredited assessors on the AAO websites.

Disclaimer

The energy values quoted are for comparison purposesonly; they are not a prediction of actual energy use. Thisrating only applies to the floor plan, construction details,orientation and climate as submitted and included in theattached drawing set that bears a stamp with the samenumber as this certificate. Changes to any of these detailscould affect the rating.

Contact

For more information on the Nationwide House EnergyRating Scheme (NatHERS), visit www.nathers.gov.auFor more information on energy efficient design andinsulation visit www.yourhome.gov.au

Nationwide House Energy Rating Scheme* Certificate

Certificate Number: W66T893KCK Date of Certificate: 17 Jun 2017 ★ Star rating: 7.6

* Nationwide House Energy Rating Scheme (NatHERS) is an initiative of the Australian, state and territorygovernments. For more details see www.nathers.gov.au

Page 6 of 6

Page 9: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family
Page 10: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family
Page 11: BUILDING ENERGY EFFICIENCY CERTIFICATE...ALM-006-03 A Opening 10 2100 2700 ENE Alfresco No ALM-006-03 A Opening 11 2100 2700 NNW Alfresco No PVC-006-01 W Opening 12 2100 2100 NNW Family