68
ENRICH ELECTRICAL SOLUTIONS DIGITAL

Bt Digital Solutions

Embed Size (px)

Citation preview

Page 1: Bt Digital Solutions

SYSTEMENRICHTO

ELECTRICALTHE

SOLUTIONSDIGITAL

Page 2: Bt Digital Solutions
Page 3: Bt Digital Solutions

THE SOLUTIONS 3

THE SOLUTIONS

10 AUTOMATIONSOLUTION FOR5SHUTTERS WithBUS/SCStechnology WithZigbeetechnology

20 AUTOMATIONSOLUTION FOR3SHUTTERSAND2CURTAINS WithBUS/SCStechnology WithZigbeetechnology

31 LIGHTSCENARIOSOLUTION WithBUS/SCStechnology WithZigbeetechnology

50 LIGHTPOINTADDITION SOLUTION WithZigbeetechnology

56 SOUNDDIFFUSIONSOLUTION 1SOURCE WithBUS/SCStechnology

61 SOUNDDIFFUSIONSOLUTION 2MULTICHANNELSOURCES WithBUS/SCStechnology

CONTENTS

WWW.BTICINO.COM

Page 4: Bt Digital Solutions

4

SOLUTIONSTHEADvANTAGES

of theThankstooursolutionsitispossibletoaddnewdevicestotheexistingelectricsystem,toexpandandenrichthefunctionsofthetraditionalsystem.Thiscanbedoneusingawiredorradiosolution.

AUTOMATION OF CURTAINS AND SHUTTERSTocontrolthemovementofoneormoreshutters/curtainsaroundthewholehome.Onesingletouchisenoughtoraiseorloweralltheshutters/curtainsofyourhome.

LIGHT SCENARIOSScenariosmakelifeinyourhomemuchmoresimpleandcomfortablethankstothesimultaneousactivationofseveralcontrolsuseddaily.

Page 5: Bt Digital Solutions

THE SOLUTIONS 5

Thankstothescenariocontrol,theusercanpreparetheroomforrelaxation,reading,watchingafilm,etc.byorderingwithasinglemovementtheswitchingonoroffofcertainlights.

SOUND DIFFUSIONTofollowyourfavouritemusicprogramineachroomofyourhomewithahighsoundquality,withperfectlookintegration.

WWW.BTICINO.COM

Page 6: Bt Digital Solutions

6

TECHNOLOGYSELECTIONof the

WIRED BUSThetransmissionofallinformationamongthedevicesaddedtothetraditionalelectricsystemisperformedthroughatwistedpaircalledBUS.TheBUScabletransmitstheinformationandthepowersupplytothedevicesandcanbeinstalledtogetherwiththeexistingenergycables.Thissolutionisparticularlysuitedfornewconstructions,orwhenimportantrefurbishmentshavetakenplace.

WIRED BUS

TECHNOLOGYSELECTIONSELECTION

WIRED

Page 7: Bt Digital Solutions

THE SOLUTIONS 7

RADIO ZIGBEE

RADIO ZIGBEEThankstotheradiotransmissionandthebatterypoweringofcontrols,thedeviceseasilyintegratewiththetraditionalelectricsystem,withouttheneedforanyadditionalwiring.Inthiswaytheexistingsystemcanbeintegratedwiththeautomationoflightsandshutters.

RADIO ZIGBEE

WWW.BTICINO.COM

Page 8: Bt Digital Solutions

8

Planimetry for the Positioning of the devices

device oPeration descriPtion

loads which can be driven

configuration of the devices

solutionsGUIDeto the

Page 9: Bt Digital Solutions

THE SOLUTIONS 9

PRESETTINGOFSySTEMANDTRACINGOFTHECONDUITS

WIRINGANDACTIvATIONOFTHEDEvICES

FUNCTIONALDIAGRAM

LISTOFDEvICESTHATMUSTBEORDERED

Below are all the steps to follow for the best possible installation of the ready-made solutions that we offer.

Thisdocumentwascreatedasaguideforthe

users,andtoprovidethemwithallthenecessaryinformationtoenable

themtoenrichtheelectricsystem.

WWW.BTICINO.COM

Page 10: Bt Digital Solutions

2

2 2 2

2

2

10

Planimetry for the Positioning of the devices

management of 5 motorized shutters or curtains using individual controls and the general control. this solution is particularly suited for new constructions or refurbishments.

in case control of several loads is required (shutters or curtains), or if several control points are to be installed, system expansion is also possible.

Legend of symbols:

distribution board

load control(general control)

flush mounted actuator (single control)

BUs - scs cable 230 vac cable shutter motor Junction box

automation solution for 5 shutters with scs BUs technology

studio

living room hallwayBathroom

Kitchen

second bathroom child

bedroom

Bedroom

Page 11: Bt Digital Solutions

THE SOLUTIONS 11

Actuator device for SINGLE control:

for local control of each individual associated/connected shutter. the type of control depends on the configurator connected to the m1 socket:�� MONOSTABLE, press and hold down the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device, until the desired shutter position is reached.�� BISTABLE, press and release the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter motor. After the command has been sent, press the lower or upper key cover again to stop the shutter in the desired position.

GENERAL control device:

to control the opening or the closing of all shutters at the same time. Configure the control for use in BISTABLE mode.

loads which can Be driven

NOTE: Protect the outputs of the relay actuators using a 10 a thermal magnetic circuit breaker

the configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.to configure the devices refer to the fUnctional diagram.

WARNING: the devices must only be configured when the system is not powered.

NOTE: the reference code for the configurators is sold in kits of 10 pieces

configUration of the devices

description of the configurators

configurator socket

configurator

Pull-out handle

DescriptionPower supply from BUS

Absorption from BUS

Dissipated power at maximum load

Relay Type of load

flush mounted 2 relay actuator

18 – 27 vdc 13.5 ma 0.9 w

c

no no 2 a 500 w

device oPeration descriPtion

www.Bticino.com

Page 12: Bt Digital Solutions

NL230 Vac

N

L1 L2

N

L1 L2

N

L1 L2

N

L1 L2

N

L1 L2

BUS SCS

NL

230 Vac

1

2

4

3 3 3 3 3

12

note: - livinglight: white device tech colour device anthracite device - aXolUte: white device tech colour device anthracite device - arteor: white device magnesium colour device - céliane: white device titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

NOTE (*):configure m1= 8 for BistaBle operationconfigure m1= m for monostaBle operation configure m1= for bistable up-down movement with the possibility of adjusting the shutter blades if the control is pressed for less than 1.5 s. Up-down to the end of stroke if the control is pressed for more than 1.5 s.

Description q.ty BTicino Legrand Size (DIN)

1 mini Power supply 230 vac 1 e49 03567 2 modules

1 Power supply 110/127 vac 1 346031 – 2 modules

total size 2 modules

list of din module devices

mini Power supply

general control

single control

single control

single control

single control

single control

vac

vac

description q.tyresidential series items

livinglight axolute arteor céliane

2 control for single and double loads 1 l4652/2 h4652/2 573974 67241

3 flush mounted actuator 2 relays 5 ln4671m2 h4671m2 573961 67249

Key cover UP/down 2 modules 6

n4911m2ahn

nt4911m2ahn

l4911m2ahn

hd4911m2ah

hc4911/2ah

hs4911/2ah

574384

574385

68108

68408

4 scs-BUs cable 1 l4669 l4669 49231 49231

configurator gen 1 3501/gen 3501/gen 49210 49210

configurator 1 1 3501/1 3501/1 49201 49201

configurator 2 1 3501/2 3501/2 49202 49202

configurator 3 1 3501/3 3501/3 49203 49203

configurator 5 1 3501/5 3501/5 49205 49205

configurator 6 1 3501/6 3501/6 49206 49206

configurator 8 1 3501/8 3501/8 49208 49208

configurator 1 3501/t 3501/t 49220 49220

configurator m 1 3501/tm 3501/tm 49221 49221

Pull-out handle 1 3502 3502 49265 49265

ring 6 - - -68083

68383

list of flush mounted devices

fUnctional diagram

list of devices that mUst Be ordered

list of din module devices

vac

vac

list of flush mounted devices

A1 = GENM1 =

A1 = 5PL1 = 1 M1 = (*)

A1 = 5PL1 = 2 M1 = (*)

A1 = 5PL1 = 3 M1 = (*)

A1 = 6PL1 = 1 M1 = (*)

A1 = 6PL1 = 2 M1 = (*)

Page 13: Bt Digital Solutions

M

PRI

035 67PRI: 220 – 240 V~ 185 – 175 mA 47/63 Hz

SCS: 27 Vdc 600 mA

SCS

PL1M1

A1

PL2M2

A2

BUS

BUS

Vac

MN

L1

L2

L

N

BUS

THE SOLUTIONS 13

110

1) Control device for the general control of 5 shutters.

Actuator with key cover for local control

Junction box

NOTE 1): recommended height

Power supply

160

1)

Apartment switchboard

Control

Rear view

Mini Power supply

NOTE: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.

Front view

Actuator

2 A max500 W max

Rear view

PREsETTINg OF sysTEM AND TRACINg OF ThE CONDuITs

WIRINg AND ACTIvATION OF ThE DEvICEs

Control

110

1)

Junction box

WWW.BTICINO.COM

Page 14: Bt Digital Solutions

2

2 2 2

2

2

14

Automation solution for 5 shutters with ZigBee® technologyUsing the Zigbee technology it is possible to add a control point (e.g. a general control) to manage shutters, by simply replacing the traditional devices with radio devices, without the need to modify the existing wiring.

The new general control consists of a surface mounted radio control.

PlAnimeTry for The PosiTioning of The devices

studio

living room hallwayBathroom

Kitchen

second bathroom child

bedroom

Bedroom

legend of symbols:

distribution board

flush mounted radio actuator (single control)

230 vac cable

shutter motor Junction boxradio control(general control)

device oPerATion descriPTion

Single control radio actuator:

for local control of each individual associated/connected shutter. The control type can be:�� BISTABLE, press and release the top section (shutter UP) or the bottom section (shutter DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter motor. After activating the control, press the bottom left key to stop the shutter in the desired position.

By pressing and holding down for more that one second the UP or the doWn keys, it is possible to adjust the position of the blades.

General control:for radio control of the opening or closing of all the shutters at the same time. This is a BisTABle type control, the same as described for the single actuator.

sToP control

UP control

doWn control

Page 15: Bt Digital Solutions

4 s

THE SOLUTIONS 15

Description Power supply / Frequency Shutter motor

Radio actuator for shutter automations

230 Vac@50/60 HzMax 500 Va Min 270 Va

110 Vac@50/60 HzMax 250 VaMin 135 Va

ProceDure:

1. Remove any key covers present.

2. Select the actuator device that will act as a Coordinator,

and press the corresponding nETWORK KEY for 4

seconds.

The Configuration of radio ZigBee® devices is performed in three stages:

1. Selection of the coordinator device and network

creation. The coordinator device MUST be connected

to the electric power line.

2. adding the devices to the network

3. association of the devices

1 - Selection of the coordinator device and network creation

This is the first operation that must be completed after wiring the devices. after its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.

To help the reader, below is a legend of the symbols used in the next pages to indicate the status of the LEDs of the devices.

LOaDS WHiCH Can BE DRiVEn

COnfigURaTiOn Of THE DEViCES

LEDS anD PUSHBUTTOnS REQUiRED fOR THE COnfigURaTiOn

nETWORK pushbutton

LEaRning pushbutton

On/Off control key

LED STaTUS

Off

On STEaDY

fLaSHing SLOWLY (1s)

fLaSHing QUiCKLY (0.25s)

fLaSHing (60ms)

fLaSHing 3 TiMES (3s)

3. The nETWORK LED (yellow) will come on steady, and after a few instants will start flashing quickly.

4. Create the network by setting the devices that will be included, as indicated in the following page.

LEaRning indicator LED

nETWORK indicator LED

Coordinator

Coordinator

4 s

WWW.BTiCinO.COM

Page 16: Bt Digital Solutions

A PL

16

2. repeat the above procedure for all devices to include in the network.

3. To complete the procedure press the neTWorK Key of the coordinator device; The corresponding neTWorK led will flAsh Three Times, while the neTWorK leds of all other devices will switch off.

2 - Adding the devices to the network1. Press the neTWorK Key of the first device to include.

The neTWorK led (yellow) turns on steady during the “network search” stage. once the stage has been completed, it will start flashing quickly.

3 s coordinatordevice

device

To check the devices belonging to a common network press the neTWorK Key of any actuator device, or the neTWorK Key of the coordinator device: the neTWorK led (yellow) of the coordinator device will flash slowly,

while the neTWorK leds (yellow) of the other Actuator devices will flash quickly. The controls must be checked individually.

device coordinator device device

cHecKING THe DeVIceS BeLoNGING To THe NeTWorK

Page 17: Bt Digital Solutions

A PL

A PL

A PL

ML2

N

L1

A PL

ML2

N

L1

ML2

N

L1

THE SOLUTIONS 17

3. Press the Key (top right). The leArning led (green) will start flashing quickly.

5. Press the UP Key (top right) on the same ACTUATOR, the connected load activates and the shutter goes UP. The leArning led (green) will go from flashing slowly to flashing quickly.

7. Press the leArning Key on the RAdiO COnTROl. The leArning leds (green) of all associated devices will go off.

1. if fitted, remove the key covers of the involved devices. 2. Press the leArning Key of the rAdio conTrol, the

leArning led (green) will flash slowly. Wait at least 1 second.

control

Actuator

general control

6. repeat the operations at points 4 and 5 for all actuators to associate to the general control.

4. Press the leArning Key of the 1st ACTUATOR (shutters), the leArning led (green) will flash slowly.

control

control

Actuator

Actuator

WWW.BTicino.com

Page 18: Bt Digital Solutions

N L

1

2

18

Functional diagram

Flush mounted radio actuator

motorized shutter

notE: repeat the connection for all 5 shutters.general control

list oF dEvicEs that must bE ordErEd

description q.tyresidential series items

livinglight axolute arteor céliane

1radio actuator for shutter

automation5 ln4595 h4595

573840

573841 67263

2radio control for shutter

automation3

n4599n (round cover plate)

l4599n (square cover plate)

ha4599 (rectangular cover plate)

hb4599 (round cover plate)

573842

573843 67264

module key cover for actuator

and uP/doWn control8

n4911ahn

nt4911ahn

l4911ahn

hd4911ah

hc4911ah

hs4911ah

supplied68100

68400

module key cover for actuator

and nEutral control8

n4911an

nt4911an

l4911an

hd4915

hc4915

hs4915

supplied68081

68381

notE: - livinglight: white device tech colour device anthracite device - aXolutE: white device tech colour device anthracite device - artEor: white device magnesium colour device - céliane: white device titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

Page 19: Bt Digital Solutions

TV/SAT IPTV

automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

TV/SAT IPTV

automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

M

N L

M

L2

N

L1

THE SOLUTIONS 19

PreseTTing of sysTem And TrAcing of The condUiTs

Wiring And AcTivATion of The devices

noTA 1): recommended height

radio actuator

Junction box

radio control

maximum distances

The maximum distance between 2 devices is:150 metres on free field.

15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).

shutter actuator

150 metres

radio control

15 metres

Wall

shutter actuator

radio control

n

l

n

l

110

1)

110

1)

WWW.BTicino.com

Page 20: Bt Digital Solutions

20

2

2 2 2

2

2

Actuator device for SINGLE control:

for local control of each individual associated/connected shutter/curtain. The type of control depends on the configurator connected to the M1 socket:�� MONOSTABLE, press and hold down the top section (shutter/curtain UP) or the bottom section (shutter/curtain DOWN) of the key cover of the actuator device, until the desired shutter/curtain position is reached.�� BISTABLE, press and release the top section (shutter/curtain UP) or the bottom section (shutter/curtain DOWN) of the key cover of the actuator device. This will send an UP-DOWN command to the shutter/curtain motor. After the command has been sent, press the lower or upper key cover again to stop the shutter/curtain in the desired position.

GENERAL control device:

to control the opening or the closing of all shutters/curtain at the same time. Configure the control for use in BISTABLE mode.

Automation solution for 3 shutters and 2 curtains with SCS BUS ® technologyManagement of 3 motorized shutters and 2 motorized curtains, with individual controls and 2 independent general controls. This solution is particularly suited for new constructions or refurbishments.

In case control of several users is required (shutters or curtains), or if several control points are to be installed, system expansion is also possible.

Load control(comandi generali)

Flush mounted actuator (single control)

SCS - BUScable

230 Vaccable

Shutter motor

Curtains motor

Junction boxDistribution board

Legend of symbols:

Studio

Living Room

HallwayBathroom

Kitchen

Second bathroom Child

bedroom

Bedroom

PLAnIMETRy FoR THE PoSITIonIng oF THE DEVICES

DEVICE oPERATIon DESCRIPTIon

Page 21: Bt Digital Solutions

THE SOLUTIONS 21

4

N

L1 L2

N

L1 L2

N

L1 L2

N

L1 L2

N

L1 L2

2 3 3 3 3 3

NL

1

BUS SCS

NL

DescriptionPower supply from BUS

Absorption from BUS

Dissipated power at maximum load

Relay Type of load

Flush mounted 2 relay actuator

18 – 27 Vdc 13.5 mA 0.9 W

C

no no 2 A 500 W

NOTE: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker

Description of the configurators

Configurator socket

Configurator

Pull-out handle

The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUnCTIonAL DIAgRAM.

WARNING: the devices must only be configured when the system is not powered.

NOTE: the reference code for the configurators is sold in kits of 10 pieces.

LoADS WHICH CAn BE DRIVEn

ConFIgURATIon oF THE DEVICES

FUnCTIonAL DIAgRAM

NOTE (*):configure M1= 8 for BISTABLE operationConfigure M1= M for MonoSTABLE operation Configure M1= for bistable up-down movement with the possibility of adjusting the shutter blades if the control is pressed for less than 1.5 s. Up-down to the end of stroke if the control is pressed for more than 1.5 s.

Mini Power supply

general control

Single control

Single control

Single control

Single control

Single control

A1 = 5PL1 = 1 M1 = (*)

A1 = AMBPL1 = 5M1 = A2 = AMBPL2 = 6M2 =

A1 = 5PL1 = 2 M1 = (*)

A1 = 5PL1 = 3 M1 = (*)

A1 = 6PL1 = 1 M1 = (*)

A1 = 6PL1 = 2 M1 = (*)

Vac

Vac

WWW.BTICIno.CoM

Page 22: Bt Digital Solutions

22

noTE: - LIVIngLIgHT: white device Tech colour device anthracite device - AXoLUTE: white device Tech colour device anthracite device - ARTEoR: white device Magnesium colour device - Céliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

Description q.ty BTicino Legrand Size (DIN)

1 Mini Power supply 230 Vac 1 E49 03567 2 modules

1 Power supply 110/127 Vac 1 346031 – 2 modules

ToTAL SIzE 2 modules

List of DIn module devices

Description q.tyResidential series items

Livinglight Axolute Arteor Céliane

2 Control for single and double loads 1 L4652/2 H4652/2 573974 67241

3 Flush mounted actuator 2 relays 5 Ln4671M2 H4671M2 573961 67249

Key cover UP/DoWn 2 modules 6

n4911M2AHn

nT4911M2AHn

L4911M2AHn

HD4911M2AH

HC4911/2AH

HS4911/2AH

574384

574385

68108

68408

1 module UP/DoWn key 6

n4911AHM

nT4911AHM

L4911AH

HD4911AH

HC4911AH

HS4911AH

574362

574363

68100

68400

4 SCS-BUS cable 1 L4669 L4669 49231 49231

Configurator gEn 1 3501/gEn 3501/gEn 49210 49210

Configurator 1 1 3501/1 3501/1 49201 49201

Configurator 2 1 3501/2 3501/2 49202 49202

Configurator 3 1 3501/3 3501/3 49203 49203

Configurator 5 1 3501/5 3501/5 49205 49205

Configurator 6 1 3501/6 3501/6 49206 49206

Configurator 8 1 3501/8 3501/8 49208 49208

Configurator 1 3501/T 3501/T 49220 49220

Configurator M 1 3501/TM 3501/TM 49221 49221

Configurator AMB 1 3501/AMB 3501/AMB 49221 49221

Pull-out handle 1 3502 3502 49265 49265

Ring 6 - - -68083

68383

List of flush mounted devices

LIST oF DEVICES THAT MUST BE oRDERED

Page 23: Bt Digital Solutions

THE SOLUTIONS 23

PL1M1

A1

PL2M2

A2

BUS

MN

L1

L2

L

N

BUS

M

PRI

035 67PRI: 220 – 240 V~ 185 – 175 mA 47/63 Hz

SCS: 27 Vdc 600 mA

SCS

BUS

Vac

PRESETTIng oF SySTEM AnD TRACIng oF THE ConDUITS

WIRIng AnD ACTIVATIon oF THE DEVICES

Actuator

2 A max500 W max

Rearview

Actuator with key cover for local control

Junction box

Control device for the general control of three shutters and the general control of two curtains.

Control

Rear view

Apartment switchboard

Power supply

Front view

Mini Power supply

noTE 1): recommended height noTE: The size of the mini power supply is equal to 2 DIn modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.

110

1)

110

1)

160 1)

WWW.BTICIno.CoM

Page 24: Bt Digital Solutions

24

2

2 2 2

2

2

Automation solution for 3 shutters and 2 curtains with ZigBee® technologyUsing the Zigbee technology it is possible to add a control point (e.g. a general control) to manage shutters and curtains, by simply replacing the traditional devices with radio devices, without the need to modify the existing wiring.

The new general control consists of a surface mounted radio control.

PlAnimeTry for The PosiTioning of The devices

distribution board

load control(general radio)

flush mounted radio actuator (single control)

230 vac cable

shutter motor

curtains motor

Junction box

legend of symbols:

studio

living room

hallwayBathroom

Kitchen

second bathroom child

bedroom

Bedroom

UP control

doWn control

sToP control

Single control radio actuator:

for local control of each individual associated/connected shutter. The control type can be:�� BisTABle, press and release the top section (shutter UP) or the bottom section (shutter doWn) of the key cover of the actuator device. This will send an UP-doWn command to the shutter motor. After activating the control, press the bottom left key to stop the shutter in the desired position.

By pressing and holding down for more that one second the UP or the doWn keys, it is possible to adjust the position of the blades.

General control:for radio control of the opening or closing of all the shutters at the same time. This is a BisTABle type control, the same as described for the single actuator.

device oPerATion descriPTion

Page 25: Bt Digital Solutions

THE SOLUTIONS 25

4 s

Loads which can be driven

Description Power supply / Frequency Shutter/Curtain motor

radio actuator for shutter/curtain automations

230 vac@50/60 hzMax 500 va Min 270 va

110 vac@50/60 hzMax 250 vaMin 135 va

configuration of the devices

ProCeDure:

1. remove any key covers present.

2. select the actuator device that will act as a coordinator,

and press the corresponding networK KeY for 4

seconds.

the configuration of radio Zigbee® devices is performed in three stages:

1. selection of the coordinator device and network

creation. the coordinator device Must be connected

to the electric power line.

2. adding the devices to the network

3. association of the devices

1 - selection of the coordinator device and network creation

this is the first operation that must be completed after wiring the devices. after its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.

to help the reader, below is a legend of the symbols used in the next pages to indicate the status of the Leds of the devices.

3. the networK Led (yellow) will come on steady, and after a few instants will start flashing quickly.

4. create the network by setting the devices that will be included, as indicated in the following page.

Learning indicator Led

networK indicator Led

Leds and Pushbuttons reQuired for the configuration

networK pushbutton

Learning pushbutton

on/off control key

Coordinator

Coordinator

Led status

off

on steadY

fLashing sLowLY (1s)

fLashing QuicKLY (0.25s)

fLashing (60ms)

fLashing 3 tiMes (3s)

www.bticino.coM

Page 26: Bt Digital Solutions

26

A PL

3 s

To check the devices belonging to a common network press the neTWorK Key of any actuator device, or the neTWorK Key of the coordinator device: the neTWorK led (yellow) of the coordinator device will flash slowly,

2. repeat the above procedure for all devices to include in the network.

3. To complete the procedure press the neTWorK Key of the coordinator device; the corresponding neTWorK led will flAsh Three Times, while the neTWorK leds of all other devices will switch off.

while the neTWorK leds (yellow) of the other Actuator devices will flash quickly. The controls must be checked individually.

device coordinator device device

2 - Adding the devices to the network1. Press the neTWorK Key of the first device to include.

The neTWorK led (yellow) turns on steady during the “network search” stage. once the stage has been completed, it will start flashing quickly.

coordinatordevice

device

CHeCKING THe DeVICeS BeLoNGING To THe NeTWorK

Page 27: Bt Digital Solutions

THE SOLUTIONS 27

A PL

A PL

A PL

ML2

N

L1

A PL

ML2

N

L1

ML2

N

L1

5. Press the UP Key (top right) on the same ACTUATOR, the connected load activates and the shutter goes UP. The leArning led (green) will go from flashing slowly to flashing quickly.

1. if fitted, remove the key covers of the involved devices. 2. Press the leArning Key of the rAdio conTrol, the

leArning led (green) will flash slowly. Wait at least 1 second.

general control for 3 shutters

4. Press the leArning Key of the 1st ACTUATOR (shutters), the leArning led (green) will flash slowly.

3. Press the Key (top right). The leArning led (green) will start flashing quickly.

control

control

control

Actuator

Actuator

Actuator

7. Press the leArning Key on the RAdiO COnTROl. The leArning leds (green) of all associated devices will go off.

6. repeat the operations at points 4 and 5 for all actuators to associate to the general control.

WWW.BTicino.com

Page 28: Bt Digital Solutions

28

A PL

A PL

A PL

ML2

N

L1

A PL

ML2

N

L1

ML2

N

L1

4. Press the leArning Key of the 1st ACTUATOR (curtains), the leArning led (green) will flash slowly.

3. Press the Key (top right). The leArning led (green) will start flashing quickly.

5. Press the UP Key (top right) on the same ACTUATOR, the connected load activates and the curtains goes UP. The leArning led (green) will go from flashing slowly to flashing quickly.

1. if fitted, remove the key covers of the involved devices. 2. Press the leArning Key of the rAdio conTrol, the

leArning led (green) will flash slowly. Wait at least 1 second.

control

control

control

ActuatorActuator

Actuator

General control for 2 curtains

7. Press the leArning Key on the RAdiO COnTROl. The leArning leds (green) of all associated devices will go off.

6. repeat the operations at points 4 and 5 for all actuators to associate to the general control.

Page 29: Bt Digital Solutions

THE SOLUTIONS 29

N L N L

1 1

fUncTionAl diAgrAm

flush mounted actuator

motorized shutter

motorized curtain

noTe: repeat the connection for all shutters and curtains.

general shutter control

general curtain control

description q.tyresidential series items

livinglight Axolute Arteor céliane

1radio actuator for shutter

automation5 ln4595 h4595

573840

573841 67263

2radio control for shutter

automation3

n4599n (round cover plate)

l4599n (square cover plate)

hA4599 (rectangular cover plate)

hB4599 (round cover plate)

573842

573843 67264

module key cover for actuator

and UP/doWn control11

n4911Ahn

nT4911Ahn

l4911Ahn

hd4911Ah

hc4911Ah

hs4911Ah

supplied68100

68400

module key cover for actuator

and neUTrAl control11

n4911An

nT4911An

l4911An

hd4915

hc4915

hs4915

supplied68081

68381

noTe: - livinglighT: white device Tech colour device anthracite device - AxolUTe: white device Tech colour device anthracite device - ArTeor: white device magnesium colour device - céliane: white device Titanium colour device WArNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

lisT of devices ThAT mUsT Be ordered

WWW.BTicino.com

Page 30: Bt Digital Solutions

30

n

TV/SAT IPTV

automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

l

n

TV/SAT IPTV

automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

l

110

1)

M

110

1)

N L

M

L2

N

L1

2

2

2 2 2 2

noTA 1): recommended height

radio actuator

Junction box

PreseTTing of sysTem And TrAcing of The condUiTs

Wiring And AcTivATion of The devices

radio control

shutter actuator

150 metres

maximum distances

The maximum distance between 2 devices is: 150 metres on free field.

15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).

radio controlradio control

15 metres

Wall

shutter actuator

Page 31: Bt Digital Solutions

EDC

B

A

H G

F

THE SOLUTIONS 31

Light scenario solution with star wiring and SCS BUS technologyThe light scenario management solution makes it possible to recreate the desired atmosphere. Simply save light scenarios in the scenario module based on the desired ambience (e.g. relax, reading, TV Vision,

wake-up), so that they may be recalled with a simple movement using the Scenario Control device. Solution realised with star wiring. All the actuators are in DIN module.

Scenario module:

it can be used to manage the scenarios created, modified and activated using the scenario control. Up to a maximum of 16 scenarios may be saved inside.

Scenario control:

It’s a device that gives the possibility of recalling, changing, or modifying the scenarios saved in the Scenario Module. With the scenario control it is possible to save up to 4 scenarios.

PLANImeTry for The PoSITIoNINg of The DeVICeS

DeVICe oPerATIoN DeSCrIPTIoN

Load controlDistribution board

Scenario control

Lamp BUS - SCS cable 230 Vac cable Junction box

Legend of symbols:

Studio

Living roomhallway

Kitchen

Second bathroom

Child bedroom

Bedroom

Bathroom

WWW.BTICINo.Com

Page 32: Bt Digital Solutions

32

DescriptionPower supply from BUS

Absorption from BUS

Dissipated power at maximum load

Type of load

2 relay actuator

18 – 27 Vdc28 mA

(SINgLe LoADS)1.7 W

�� 6 A / 1400 W (incandescence lamps and energy saving halogens) �� 10 a / 2300 w (resistive loads) �� 1 a / 250 w (linear fluorescent lamps)�� 250 w max 4 lampade (compact fluorescent lamps) �� 1 a / 250 w (electronic transformers) �� 2 a cosφ 0.5 / 500 va (ferromagnetic transformers)

2 x 400 W multi load Dimmer Actuator

100 - 240 Vac @ 50/60 hz

5 mA 8 W

�� 1.7 A / 400 W (incandescence lamps and energy saving halogens)�� 1.7 A / 400 W (electronic transformers) �� 1.7 A / 400 W (ferromagnetic transformers)

WARNING: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker

The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the fUNCTIoNAL DIAgrAm.

WARNING: the devices must only be configured when the system is not powered.

NOTE: the reference code for the configurators is sold in kits of 10 pieces

Description of the configurators

Configurator socket

Configurator

Pull-out handle

Configurator

Configurator socket

Pull-out handle

CoNfIgUrATIoN of The DeVICeS

LoADS WhICh CAN Be DrIVeN

Page 33: Bt Digital Solutions

ART.F420ART.F411/2

1 2 31 2 3 4

ART.F411/2

1 2 3 41 2 3 4

ART.F411/2

1 2 31 2 3 4

ART.F411/2

1 2 3 41 2 3 4

ART.F411/2

1 2 31 2 3 4

ART.F411/2

1 2 3 41 2 3 4

ε

ON/+

OFF/-

RL/C

F417U2

2x400 VA

ON/+

OFF/-

MG2

PL2G

1PL1A

NL

NL

A B C D E F G H

1

2

3

4 4

4

7

5 5 5 5 5

5

5

56 6

A A B C D E F G H

THE SOLUTIONS 33

fUNCTIoNAL DIAgrAm

A1 = GENPL1 = –M1 = O/IA2 = 1PL2 = 1M2 = O/I

AF = 1PL1 = 1M1 = O/IA2 = 1PL2 = 2M2 = O/I

A = –PL = 1M = 1(*)N = –DEL = –

A1 = 2PL1 = 1M1 = O/IA2 = –PL2 = –M2 = –

A1 = 2PL1 = 2M1 = O/IA2 = –PL2 = –M2 = –

A1 = 3PL1 = 1M1 = O/IA2 = –PL2 = –M2 = –

A1 = 3PL1 = 2M1 = O/IA2 = –PL2 = –M2 = –

A = –PL = 1M = 2(*)N = –DEL = –

A1 = 4PL1 = 1M1 = O/IA2 = –PL2 = –M2 = –

A1 = 4PL1 = 2M1 = O/IA2 = –PL2 = –M2 = –

A = 2PL1 = 1PL2 = 2G = –

A = 3PL1 = 1PL2 = 2G = –

A = 4PL1 = 1PL2 = 2G = –

A1 = -PL1 = 1

A = 1PL1 = 1G1 = -PL2 = 2G2 = -M = -

mini Power supply

Vac

VacScenario module

Dimmer actuator 2 relay

actuator

2 relay actuator

2 relay actuator

Control Control Control Control ControlScenario control

NoTe(*): by inserting the same configurator in m, the scenario controls will activate the same scenarios.

Control ControlScenario control

WWW.BTICINo.Com

Page 34: Bt Digital Solutions

34

LIST of DeVICeS ThAT mUST Be orDereD

List of flush mounted devices

NoTe: - LIVINgLIghT: white device Tech colour device anthracite device - AXoLUTe: white device Tech colour device anthracite device - ArTeor: white device magnesium colour device - Céliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

Description q.tyresidential series items

Livinglight Axolute Arteor Céliane

5 Control for single and double loads 8 L4652/2 h4652/2 573974 67241

6 Scenario control 2N4680 NT4680 L4680

hD4680 hC4680 hS4680

573902 573903

67217 67218

Key cover oN-off-geN

regulation 1 module1

N4911AfN NT4911AfN L4911AfN

hD4911Af hC4911Af hS4911Af

574373 (left) 574372 (left)

68105 (left) 68405 (left)

Key cover oN-off regulation

1 module3

N4911AIN NT4911AIN L4911AIN

hD4911AI hC4911AI hS4911AI

573964 (left) 573960 (right) 573965 (left) 573961 (right)

68264 (left) 68265 (right) 68564 (left) 68565 (right)

Key cover oN-off 2 modules 6N4911/2AgNNT4911/2AgNL4911/2AgN

hD4911m2AghC4911/2Ag hS4911/2Ag

574382 574383

68085 68385

7 BUS - SCS cable 1 L4669 L4669 49231 49231

Configurator geN 1 3501/geN 3501/geN 49210 49210

Configurator 1 1 3501/1 3501/1 49201 49201

Configurator 2 1 3501/2 3501/2 49202 49202

Configurator 3 1 3501/3 3501/3 49203 49203

Configurator 4 1 3501/4 3501/4 49204 49204

Configurator 0/1 1 3501/01 3501/01 49216 49216

Pull-out handle 1 3502 3502 49265 49265

ring 8 - - - 68083 68383

Description q.ty BTicino Legrand Size(DIN)

1 mini Power supply 230 Vac 1 e49 03567 2 modules

1 Power supply 110/127 Vac 1 346031 – 2 modules

2 Scenario module 1 f420 03551 2 modules

3 2 x 400 W multi load Dimmer Actuator 1 f417U2 02622 6 modules

4 2 relay actuator 3 f411/2 03842 6 modules

ToTAL SIZe 16 modules

List of DIN module devices

Page 35: Bt Digital Solutions

ON

OFF

PRI

035 67PRI: 220 – 240 V~ 185 – 175 mA 47/63 Hz

SCS: 27 Vdc 600 mA

SCS

PL1M1

A1

PL2M2

A2

BUS

ON

OFF

ON

OFF

THE SOLUTIONS 35

WIrINg AND ACTIVATIoN of The DeVICeS

PreSeTTINg of SySTem AND TrACINg of The CoNDUITS

front view

mini Power supply

NoTe: The size of the mini power supply is equal to 2 DIN modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.

230 Vac

BUS

Apartment switchboard

Power supply and DIN actuator

NoTe 1): recommended height

Control device for the management of lights.

Control

rear viewScenario control device

Dimmer light control device

160 1)

110 1)

WWW.BTICINo.Com

Page 36: Bt Digital Solutions

ON

OFF

ON

OFF

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

36

Procedure for programming a scenario: Procedure for deleting one or more scenarios:

1. In the scenario module press the programming enable pushbutton.

The corresponding LeD turns green: the module is enabled.

2. Press the key to program for more than 4 seconds.

When the LeD turns on release the key. The LeD will start flashing, confirming that the programming mode is active.

3. Set the sequence of the commands making up the scenario.

t > 4 sec.

Press and hold down the key for the scenario to remove, waiting for the LeD to come on and then to start fLAShINg QUICKLy.To cancel all the scenarios stored in the scenario module press the reset pushbutton of the module.

In the scenario module press the progr amming enable pushbutton.

The corresponding LeD turns green: the module is enabled.

t > 8 sec.

To add, modify, or remove a command from the scenario repeat the sequence.

4. Press the key to complete programming.

To activate the scenario press the corresponding key.

At the end of programming it is recommended to disable the possibility of modifying the scenarios, using the enable/disable pushbutton of the scenario module (f420). The corresponding LeD turns red

ON

ON

ON

ON

Page 37: Bt Digital Solutions

Studio

Living Room

Kitchen

Second bathroom

Child bedroom

Bedroom

Bathroom

EDC

B

A

H G

F

THE SOLUTIONS 37

Legend of symbols:

Light scenario solution with distributed wiring and SCS BUS technologyThe light scenario management solution makes it possible to recreate the desired atmosphere. Simply save light scenarios in the scenario module based on the desired ambience (e.g. relax, reading, TV Vision, wake-up), so that

they may be recalled with a simple movement using the Scenario Control device. Solution created with distributed wiring. Flush mounted actuators are used when possible.

Scenario module:

it can be used to manage the scenarios created, modified and activated using the scenario control. Up to a maximum of 16 scenarios may be saved inside.

Scenario control:

It’s a device that gives the possibility of recalling, changing, or modifying the scenarios saved in the Scenario Module. With the scenario control it is possible to save up to 4 scenarios.

Load controlDistribution board

Scenario control

Lamp BUS - SCS cable

230 Vac cable

Junction box

PLanimeTRy FoR The PoSiTioning oF The DeViCeS

DeViCe oPeRaTion DeSCRiPTion

Studio

Living Room hallway

Kitchen

Second bathroom

Child bedroom

Bedroom

Bathroom

DeViCe oPeRaTion DeSCRiPTion

WWW.BTiCino.Com

Page 38: Bt Digital Solutions

38

DescriptionPower supply from BUS

Absorption from BUS

Dissipated power at maximum load

Type of load

2X400 W multiload Dimmer actuator

18 – 27 Vdc28 ma

(SingLe LoaDS)8 W

�� 6 a / 1400 w (incandescence lamps and energy saving halogens) �� 10 a / 2300 w (resistive loads) �� 1 a / 250 w (linear fluorescent lamps)�� 250 w max 4 lampade (compact fluorescent lamps) �� 1 a / 250 w (electronic transformers) �� 2 a cosφ 0,5 / 500 va (ferromagnetic transformers)

Control actuator

18-27 Vdc 14 ma 8 W

�� 1.7 A / 400 W (incandescence lamps and energy saving halogens)�� 1.7 A / 400 W (electronic transformers) �� 1.7 A / 400 W (ferromagnetic transformers)

WARNING: Protect the outputs of the relay actuators using a 10 A thermal magnetic circuit breaker

The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUnCTionaL DiagRam.

WARNING: the devices must only be configured when the system is not powered.

NOTE: the reference code for the configurators is sold in kits of 10 pieces.

LoaDS WhiCh Can Be DRiVen

ConFigURaTion oF The DeViCeS

Description of the configurators

Configurator socket

Configurator

Pull-out handle

Pull-out handle

Configurator

Configurator socket

Page 39: Bt Digital Solutions

ART.F420

ε

ON/+

OFF/-

RL/C

F417U2

2x400 VA

ON/+

OFF/-

MG2

PL2G

1PL1A

NL

NL 1

2

3

7

5

5

6

A B

C

D E F G H

A A B

C D E F G H

4 4 4 4 4 4

6

ART.F420

ε

ON/+

OFF/-

RL/C

F417U2

2x400 VA

ON/+

OFF/-

MG2

PL2G

1PL1A

NL

NL

C D E F G H

A A B

THE SOLUTIONS 39

FUnCTionaL DiagRam

mini Power supply Scenario

moduleDimmer actuator

actuator/ Control

actuator/ Control

actuator/ Control

actuator/ Control

actuator/ Control

A1 = 2PL1 = 1M1 = O/IA2 = –PL2 = –M2 = –

A1 = 2PL1 = 2M1 = O/IA2 = –PL2 = –M2 = –

A1 = 3PL1 = 1M1 = O/IA2 = –PL2 = –M2 = –

A1 = 3PL1 = 2M1 = O/IA2 = –PL2 = –M2 = –

A1 = 4PL1 = 1M1 = O/IA2 = –PL2 = –M2 = –

A1 = 4PL1 = 2M1 = O/IA2 = –PL2 = –M2 = –

A1 = –PL1 = 1

A = 1PL1 = 1G1 = –PL2 = 2G2 = –M = –

actuator/ Control

A1 = GENPL1 = –M1 = O/IA2 = 1PL2 = 1M2 = O/I

AF = 1PL1 = 1M1 = O/IA2 = 1PL2 = 2M2 = O/I

A = –PL = 1M = 1(*)N = –DEL = –

Control Control Scenario control

Scenario control

A = –PL = 1M = 2(*)N = –DEL = –

noTe(*): by inserting the same configurator in m, the scenario controls will activate the same scenarios.

Vac

Vac

WWW.BTiCino.Com

Page 40: Bt Digital Solutions

40

Description q.tyResidential series items

Livinglight axolute arteor Céliane

4 Flush mounted actuator/control 6 Ln4671m2 h4671m2 573961 67249

5 Single and double load control 2 L4652/2 h4652/2 573974 67241

6 Scenario control 2n4680 nT4680 L4680

hD4680 hC4680 hS4680

573902 573903

67217 67218

Key cover on-oFF-gen

regulation 1 module1

n4911aFn nT4911aFn L4911aFn

hD4911aF hC4911aF hS4911aF

574373 (left) 574372 (left)

68105 (left) 68405 (left)

Key cover on-oFF regulation

1 module3

n4911ain nT4911ain L4911ain

hD4911ai hC4911ai hS4911ai

573964 (left) 573960 (right) 573965 (left) 573961 (right)

68264 (left) 68265 (right) 68564 (left) 68565 (right)

Key cover on-oFF 2 modules 6n4911/2agnnT4911/2agnL4911/2agn

hD4911m2aghC4911/2ag hS4911/2ag

574382 574383

68085 68385

7 BUS - SCS cable 1 L4669 L4669 49231 49231

Configurator gen 1 3501/gen 3501/gen 49210 49210

Configurator 1 1 3501/1 3501/1 49201 49201

Configurator 2 1 3501/2 3501/2 49202 49202

Configurator 3 1 3501/3 3501/3 49203 49203

Configurator 4 1 3501/4 3501/4 49204 49204

Configurator 0/1 1 3501/01 3501/01 49216 49216

Pull-out handle 1 3502 3502 49265 49265

Ring 8 - - - 68083 68383

List of flush mounted devices

noTe: - LiVingLighT: white device Tech colour device anthracite device - aXoLUTe: white device Tech colour device anthracite device - aRTeoR: white device magnesium colour device - Céliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

Description q.ty BTicino Legrand Size(Din)

1 mini Power supply 230 Vac 1 e49 03567 2 modules

1 Power supply 110/127 Vac 1 346031 – 2 modules

2 Scenario module 1 F420 03551 2 modules

3 2 x 400 W multi load Dimmer actuator 1 F417U2 02622 6 modules

ToTaL SiZe 10 modules

List of DIN module devices

LiST oF DeViCeS ThaT mUST Be oRDeReD

Page 41: Bt Digital Solutions

PRI

035 67PRI: 220 – 240 V~ 185 – 175 mA 47/63 Hz

SCS: 27 Vdc 600 mA

SCS

PL1M1

A1

PL2M2

A2

BUS

ON

OFF

ON

OFF

THE SOLUTIONS 41

apartment switchboard

Power supply and Din actuator

Scenario control device

Dimmer light control device

noTe 1): recommended heightnoTe: The size of the mini power supply is equal to 2 Din modules and can be installed in the electric control panel of the house together with a dedica-ted thermal magnetic protection circuit breaker.

PReSeTTing oF SySTem anD TRaCing oF The ConDUiTS

WiRing anD aCTiVaTion oF The DeViCeS

Control

Rear view

Front view

mini Power supply

230 Vac

BUS

160 1)

110 1)

WWW.BTiCino.Com

Page 42: Bt Digital Solutions

ON

OFF

ON

OFF

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

42

ON

OFF

ON

OFF

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

DEL

ART.F420

Procedure for programming a scenario:

1. in the scenario module press the programming enable pushbutton.

The corresponding LeD turns green: the module is enabled.

2. Press the key to program for more than 4 seconds.

When the LeD turns on release the key. The LeD will start flashing, confirming that the programming mode is active.

To add, modify, or remove a command from the scenario repeat the sequence.

3. Set the sequence of the commands making up the scenario.

4. Press the key to complete programming.

To activate the scenario press the corresponding key.

Procedure for deleting one or more scenarios:

Press and hold down the key for the scenario to remove, waiting for the LeD to come on and then to start FLaShing QUiCKLy.To cancel all the scenarios stored in the scenario module press the reset pushbutton of the module.

in the scenario module press the programming enable pushbutton.

The corresponding LeD turns green: the module is enabled.

ON

ON

at the end of programming it is recommended to disable the possibility of modifying the scenarios, using the enable/disable pushbutton of the scenario module (F420). The corresponding LeD turns red.

t > 4 sec.

ON

t > 8 sec.

ON

Page 43: Bt Digital Solutions

ON

OFF

THE SOLUTIONS 43

DIMMER radio actuator for light control:

for the local control of lamps and loads.Press and release the ON key to enable the load at 66% of its power. To increase the power at the maximum level, hold down the key. Press and release the OFF key to enable the load at 33% of its power. To decrease the power down to the minimum level, hold down the key.

Press the left key to switch the load on and off.

Legend of symbols:

Distribution board

Radio actuator 230 Vac cableLampScenario radio control

ON and adjustment pushbutton

OFF and adjustment pushbutton

ON/OFF pushbutton

Scenario 2

Scenario 4Scenario 3

Scenario 1

Scenario management radio control:

for the management of 4 scenarios, which can be saved and recalled using the control itself, or a remote control.

Radio remote control:

with 4 pushbuttons for scenario control.

Scenario 1

Scenario 2

Scenario 3Scenario 4

Light scenario solution with ZigBee® technology Using radio dimmer and radio scenario control actuators, with the Zigbee technology it is possible to set light scenarios depending on the desired ambiance (e.g. relax, reading, watching TV, night).

The radio scenario control is capable of saving up to 4 scenarios maximum. Scenarios can also be recalled using a remote control.

PLaNimeTry FOr The POSiTiONiNg OF The deViceS

deVice OPeraTiON deScriPTiON

Studio

Kitchen Bedroom

Living room

hallwayBathroom

Second bathroom child

bedroom

WWW.BTiciNO.cOm

Page 44: Bt Digital Solutions

44

DescriptionPower supply/ frequency

Incandescence lamps

Halogen lamps

Ferromagnetic lamps

Electronic transformers

Radio actuator DIMMER

230 Vac@50/60 HzMax 300 W MIn 60 W

Max 300 W MIn 60 W

Max 300 W MIn 60 W

Max 300 W MIn 60 W

110 Vac@50/60 HzMax 150 WMin 60 W

Max 150 WMin 60 W

Max 150 WMin 60 W

Max 150 WMin 60 W

ProcEDurE:

1. Remove any key covers present.

2. Select the actuator device that will act as a Coordinator,

and press the corresponding nETWORK KEY for 4

seconds.

The Configuration of radio ZigBee® devices is performed in three stages:

1. Selection of the coordinator device and network

creation. The coordinator device MUST be connected

to the electric power line.

2. Adding the devices to the network.

3. association of the devices.

1 - Selection of the coordinator device and network creation.

This is the first operation that must be completed after wiring the devices. after its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.

To help the reader, below is a legend of the symbols used in the next pages to indicate the status of the LEDs of the devices.

3. The nETWORK LED (yellow) will come on steady, and after a few instants will start flashing quickly.

4. Create the network by setting the devices that will be included, as indicated in the following page.

LEaRnInG indicator LED

nETWORK indicator LED

LEDS anD PUSHBUTTOnS REQUIRED FOR THE COnFIGURaTIOn

nETWORK pushbutton

LEaRnInG pushbutton

On/OFF control key

Coordinator

Coordinator

LOaDS WHICH Can BE DRIVEn

COnFIGURaTIOn OF THE DEVICES

LED STaTUS

OFF

On STEaDY

FLaSHInG SLOWLY (1s)

FLaSHInG QUICKLY (0.25s)

FLaSHInG (60ms)

FLaSHInG 3 TIMES (3s)

4 s

Page 45: Bt Digital Solutions

A PL

THE SOLUTIONS 45

To check the devices belonging to a common network press the NeTWOrK Key of any actuator device, or the NeTWOrK Key of the coordinator device: the NeTWOrK Led (yellow) of the coordinator device will flash slowly,

2. repeat the above procedure for all devices to include in the network.

3. To complete the procedure press the NeTWOrK Key of the coordinator device; The corresponding NeTWOrK Led will FLaSh Three TimeS, while the NeTWOrK Leds of all other devices will switch off.

while the NeTWOrK Leds (yellow) of the other actuator devices will flash quickly. The controls must be checked individually.

2 - adding the devices to the network1. Press the NeTWOrK Key of the first device to include.

The NeTWOrK Led (yellow) turns on steady during the “network search” stage. Once the stage has been completed, it will start flashing quickly.

3 s coordinatordevice

device

cHEcKING THE DEVIcES BELoNGING To THE NETWoRK

device coordinator device device

WWW.BTiciNO.cOm

Page 46: Bt Digital Solutions

100 %

46

1. if fitted, remove the key covers of the involved devices.

2. Press the LearNiNg Key of the scenario control, the learNiNg Led (green) will flash slowly.

Procedure:

4. Press the LearNiNg Key of the first Dimmer actuator. The LearNiNg Led (green) will flash slowly.

5. Press the ON Key (bottom left) of the first dimmer acTUaTOr. The LearNiNg Led (green) will start flashing quickly.

The scenario consists of the simultaneous activation of several loads, with the objective of creating a specific comfort situation. as an example, below is a description of the procedure for creating a scenario for switching ON two dimmer light points, one at 50% and one at 100% of its power.

configuration of the scenario functions

3. Press Key 1; the LearNiNg Led (green) will start flashing quickly.

6. Press the LearNiNg Key of the second dimmer actuator. The LearNiNg Led (green) will flash slowly.

7. Press the ON Key (bottom left) of the second dimmer actuator. The LearNiNg Led (green) will start flashing quickly.

Scenario control

Scenario control

dimmer actuator

100 %

Page 47: Bt Digital Solutions

50 %

THE SOLUTIONS 47

9. Press the LearNiNg Key of the SceNariO cONTrOL. The LearNiNg Key (green) of the dimmer acTUaTOrS and of the SceNariO cONTrOL will switch off.

10. check that the scenario has been programmed correctly by switching all the lights off and pressing pushbutton no. 1 of the SceNariO cONTrOL. if correctly set, the lights will switch on at the level set during the configuration procedure.

8. Press and hold down the – Key (bottom right) until the desired brightness value has been reached (e.g. 50%). The LearNiNg Led (green) will start flashing quickly.

Scenario controldimmer actuator 1

dimmer actuator 2

WWW.BTiciNO.cOm

Page 48: Bt Digital Solutions

L L L

1 1 1

48

FUNcTiONaL diagram

LiST OF deViceS ThaT mUST Be Ordered

description q.tyresidential series items

Livinglight axolute arteor céliane

1 radio actuator dimmer 3 LN4593 h4593573816

573817 67237

2 radio scenario control 1N4589N (round cover plate)

L4589N (square cover plate)

ha4589 (square cover plate)

hB4589 (round cover plate)

573848

573849 67240

3 radio remote control 1 3528N 3528N 573870 573870

1 module light actuator

key cover dimmer symbol3

N4911aiN

NT4911aiN

L4911aiN

hd4911ai

hc4911ai

hS4911ai

supplied68265

68565

1 module light actuator

key cover NeUTraL3

N4915N

NT4915N

L4915N

hd4915Ba

hc4915Ba

hS4915Ba

supplied68081

68381

1 module scenario control

key cover2

N4911N

NT4911N

L4911N

hd4911

hc4911

hS4911

supplied68081

68381

NOTe: - LiViNgLighT: white device Tech colour device anthracite device - axOLUTe: white device Tech colour device anthracite device - arTeOr: white device magnesium colour device - céliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

Flush mounted radio actuator dimmer

Flush mounted radio actuator dimmer

Flush mounted radio actuator dimmer

Radio scenario controlRadio remote control

Page 49: Bt Digital Solutions

L

ON

OFF

N

L

TV/SAT IPTV

automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

N

L

TV/SAT IPTV

automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

THE SOLUTIONS 49

PreSeTTiNg OF SySTem aNd TraciNg OF The cONdUiTS

WiriNg aNd acTiVaTiON OF The deViceS

maximum distances

The maximum distance between 2 devices is:150 metres on free field.

15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).

radio light actuator

radio light actuator

radio control

radio light actuator

Junction box

radio scenario control

150 metres

15 metres

Wall

110

1)

WWW.BTiciNO.cOm

Page 50: Bt Digital Solutions

50

Solution for the addition of a light point with ZigBee® technologyThe Zigbee technology gives the possibility of adding a light point to manage the lighting of the room. The traditional switch is replaced by a radio actuator.

The new light point consists of a radio control surface mounted on the wall.

Radio actuator 230 Vac cableLampRadio control

Legend of symbols:

Distribution board

DeVice opeRaTion DeScRipTion

ON/OFF radio actuator for light control:for the local control of lamps and loads

Radio control:for on/oFF control of a group of radio actuators. Blank

plateon/oFF pushbutton

Studio

Living Room HallwayBathroom

Kitchen

Second bathroom

child bedroom

Bedroom

pLanimeTRy FoR THe poSiTioning oF THe DeViceS

Page 51: Bt Digital Solutions

THE SOLUTIONS 51

DescriptionPower supply/ frequency

Incandescence lamps

Halogen lampsFerromagnetic lamps

Electronic transformers

Radio actuator for light automation

230 Vac@50/60 HzMax 400 W Min 60 W

Max 400 W Min 60 W

Max 400 W Min 60 W

Max 400 W Min 60 W

110 Vac@50/60 HzMax 200 WMin 60 W

Max 200 WMin 60 W

Max 200 WMin 60 W

Max 250 WMin 135 W

Loads WHicH can be dRiVen

configuRation of tHe deVices

ProcEDurE:

1. Remove any key covers present.

2. select the actuator device that will act as a coordinator,

and press the corresponding netWoRK KeY for 4

seconds.

the configuration of radio Zigbee® devices is performed in three stages:

1. selection of the coordinator device and network

creation. the coordinator device Must be connected

to the electric power line.

2. adding the devices to the network

3. association of the devices

1 - selection of the coordinator device and network creation.

this is the first operation that must be completed after wiring the devices. after its definition, the coordinator will store all information relating to all the devices making up the network, and will manage the transfer of information among the devices.

to help the reader, below is a legend of the symbols used in the next pages to indicate the status of the Leds of the devices.

3. the netWoRK Led (yellow) will come on steady, and after a few instants will start flashing quickly.

Leds and PusHbuttons ReQuiRed foR tHe con-figuRation

Led status

off

on steadY

fLasHing sLoWLY (1s)

fLasHing QuicKLY (0,25s)

fLasHing (60ms)

fLasHing 3 tiMes (3s)

4. create the network by setting the devices that will be included, as indicated in the following page.

Coordinator

Coordinator

LeaRning indicator Led

netWoRK indicator Led

netWoRK pushbutton

LeaRning pushbutton

on/off control key

4 s

WWW.bticino.coM

Page 52: Bt Digital Solutions

A PL

52

To check the devices belonging to a common network press the neTWoRK Key of any actuator device, or the neTWoRK Key of the coordinator device: the neTWoRK LeD (yellow) of the coordinator device will flash slowly,

2. Repeat the above procedure for all devices to include in the network.

3. To complete the procedure press the neTWoRK Key of the coordinator device; The corresponding neTWoRK LeD will FLaSH THRee TimeS, while the neTWoRK LeDs of all other devices will switch off.

while the neTWoRK LeDs (yellow) of the other actuator devices will flash quickly. The controls must be checked individually.

2 - adding the devices to the network1. press the neTWoRK Key of the first device to include.

The neTWoRK LeD (yellow) turns on steady during the “network search” stage. once the stage has been completed, it will start flashing quickly.

3 sDevice

cHEcKING THE DEVIcES BELONGING TO THE NETWORK

Device coordinator Device Device

coordinator

Device

Page 53: Bt Digital Solutions

A PL

A PL

A PL

A PL

THE SOLUTIONS 53

3. press the on Key (bottom right). The LeaRning LeD (green) will start flashing quickly.

noTe: repeat the procedure described at points 2 and 3 for each command to be associated to the actuator.

5. press the on Key (bottom right) on the ActuAtor. The load connected turns on, the LeaRning LeD (green) changes FLaSHing mode, from slow to quick.

6. press the LeaRning Key on the rAdio control. The LeaRning LeDS (green) of all associated devices will go off.

3 - association of the devices1. if fitted, remove the key covers of the involved devices.

2. press the LeaRning Key of the rAdio control, the LeaRning LeD (green) will flash slowly.

4. press the ActuAtor To associate to the LeaRning Key. The LeaRning LeD (green) will start flashing slowly.

control

control

actuator

actuator

control

actuator

WWW.BTicino.com

Page 54: Bt Digital Solutions

A PL

L

1

2

54

7. The devices are now associated: to check that the configuration procedure has been performed correctly press the oFF Key on the radio control; the load connected to the actuator should go off.

otherwise repeat the association procedure described.

FuncTionaL DiagRam

LiST oF DeViceS THaT muST Be oRDeReD

Description q.tyResidential series items

Livinglight Axolute Arteor céliane

1 Light control on/oFF radio actuator 1 Ln4590 H45920573812

57381367231

2 Light radio control 1n4596n (round cover plate)

L4596n (square cover plate)

Ha4596 (square cover plate)

HB4596 (round cover plate)

573834

57383567235

1 module key cover for actuator and light control 4

n4915an

nT4915an

L4915an

HD4915Ba

Hc4915Ba

HS4915Ba

supplied68110 (right)

68410 (right)

Flush mounted on/oFF radio actuatorRadio light control

Page 55: Bt Digital Solutions

L

N

L

TV/SAT IPTV

automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

N

L

TV/SAT IPTV

automazione antifurto termoregolazione videocitofonia controllo controllo carichilan energia luci tvcc www irrigazione

THE SOLUTIONS 55

Maximum distances

The maximum distance between 2 devices is:150 metres on free field.

15 metres for closed areas (the presence of masonry or metal walls greatly reduces the signal strength).

Junction box

Radio actuator

Radio control

PRESETTING OF SYSTEM AND TRACING OF THE CONDUITS

WIRING AND ACTIVATION OF THE DEVICES

110

1)

Radio light actuator

Radio light actuator

Radio control

150 metres

15 metres

Wall

WWW.BTICINO.COM

Page 56: Bt Digital Solutions

ON

OFF

56

1 Source sound system solution with SCS BUS technologyThe 1 source sound system solution gives the possibility of installing a sound system in the room, with the option of following the favourite music program in each room,

with high sound quality. The installation is simple, flexible, and fast.

Flush mounted stereo amplifier:it amplifies the stereo signal on the BUS and drives up to two loudspeakers with impedance between 8 and 16 OHMs. The front of the amplifier includes two pushbuttons, used to switch the loudspeakers on/off (short pressure);�� adjust the output volume (extended pressure);�� cycle through the saved radio stations.

Radio Tuner:it’s capable of receiving FM radio stations. The front pushbuttons and the backlit display give the possibility of adjusting the device, store radio stations in the memory, display RDS messages and the tuned frequency. The radio is fitted with an internal wire antenna. In case of insufficient signal inside the building, a coaxial type connection may be used. For the programming procedure see the CD supplied with the product.

Studio

Living Room

HallwayBathroom

Kitchen

Second bathroom Child

bedroom

Bedroom

Legend of symbols:

Distribution board

BUS - SCScable

Audio cableAmplifier Loudspeaker

PLAnIMeTRy FOR THe POSITIOnIng OF THe DevICeS

DevICe OPeRATIOn DeSCRIPTIOn

Flush mounted stereo amplifier

False ceiling mounted loudspeakers:20 W power, diam. 10 cm, springs for easy fastening.

Page 57: Bt Digital Solutions

PRI

SCS A-V SCS

346030

PRI: 220 - 240V~185-175mA50/60Hz

SCS A-V 27VdcSCS 600mA

ON

OFF

ON

OFF

ON

OFF

ON

OFF

BUS

1 2

3 3

4 4

5

6

THE SOLUTIONS 57

COnFIgURATIOn OF THe DevICeS

FUnCTIOnAL DIAgRAM

The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUnCTIOnAL DIAgRAM.

WARNING: the devices must only be configured when the system is not powered.

NOTE: the reference code for the configurators is sold in kits of 10 pieces

Description of the confi gurators

Confi gurator socket

Confi gurator

Pull-out handle

Line terminator

Amplifier

230 vac

LIvIng ROOM BeDROOMLoudspeaker Loudspeaker

Amplifier

Mini Power supply

In/out wiring

Radio Tuner

S = 1MEM = 2

A = 1PF = 1

A = 1PF = 2

WWW.BTICInO.COM

Page 58: Bt Digital Solutions

58

LIST OF DevICeS THAT MUST Be ORDeReD

List of flush mounted devices

Description q.tyResidential series items

Livinglight Axolute Arteor Céliane

3 Flush mounting amplifier 2 L4562 H4562 573976 67302

1 module Diffusion functions

key cover2

n4911BnF

nT4911BnF

L4911BnF

HD4911BF

HC4911BF

HS4911BF

573966 (right)

573967 (right)

68263 (right)

68563 (right)

1 module On-OFF & adjustment

key cover2

n4911AIn

nT4911AIn

L4911AIn

HD4911AI

HC4911AI

HS4911AI

573964 (left)

573965 (left)

68264 (left)

68564 (left)

4 False ceiling mounted loudspeakers 4 L4566/10 L4566/10 573982 573982

5 BUS - SCS cable 1 336904 336904 573999 573999

6 Line terminator 1 3499 3499 3589 3589

Configurator 1 1 3501/1 3501/1 49201 49201

Configurator 2 1 3501/2 3501/2 49202 49202

Pull-out handle 1 3502 3502 49265 49265

Ring 2 - - -68083

68383

Description q.ty BTicino Legrand Size(DIn)

1 Mini Power supply 230 vac 1 346030 - 2 modules

1 Mini Power supply 110/127 vac 1 346031 - 2 modules

2 Radio Tuner 1 F500n 03582 4 modules

TOTAL SIZe 6 modules

List of DIn module devices

nOTe: - LIvIngLIgHT: white device Tech colour device anthracite device - AXOLUTe: white device Tech colour device anthracite device - ARTeOR: white device Magnesium colour device - Céliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

Page 59: Bt Digital Solutions

ON

OFF

BUSPRI

035 67PRI: 220 – 240 V~ 185 – 175 mA 47/63 Hz

SCS: 27 Vdc 600 mA

SCS

THE SOLUTIONS 59

PReSeTTIng OF SySTeM AnD TRACIng OF THe COnDUITS

WIRIng AnD ACTIvATIOn OF THe DevICeS

Flush mounted amplifier for the management of the sound source.

Apartment switchboard

Power supply and radio tuner

nOTe 1): recommended height nOTe: The size of the mini power supply is equal to 2 DIn modules and can be installed in the electric control panel of the house together with a dedicated thermal magnetic protection circuit breaker.

110

1)

Amplifier

Rear view

BUS

Front view

Mini Power supply

vac

Radio Tuner

160 1)

WWW.BTICInO.COM

Page 60: Bt Digital Solutions

A

60

�� Quickly press and release the “M” pushbutton for the selection of the position number where the station will be stored.

�� The display shows the position where the station will be saved (A).

�� Press the forward/back pushbuttons to tune the radio to the desired frequency.

�� When changing the frequency, the number displayed will start flashing, to indicate that the frequency currently displayed is different from the stored frequency.

�� Once the desired station has been found, press and hold the “M” pushbutton until the two LeDs start flashing.

�� Release the pushbutton. The radio station has now been saved.

�� To save other stations repeat the same procedure.

The device gives the possibility of storing up to 10 radio stations. As a rule, when the tuner is supplied no radio stations are stored.

Procedure for storing radio stations

Page 61: Bt Digital Solutions

ON

OFF

THE SOLUTIONS 61

2 multichannel sources sound system solution with SCS BUS technology

The 2 multichannel sources sound system solution gives the possibility of installing a sound system in the room, with the option of selecting the favourite sound source,

and have different music played in different rooms, with high sound quality. The installation is simple, flexible, and fast.

RCA input:provides interfacing, and the possibility of adapting the level of signal of an external source. The connection with the external source is by means of two female RCA connectors (red = right channel; white = left channel). The knob is used to adjust the sensitivity of the input signal. For optimum adjustment the corresponding LED must flash.

False ceiling mounted loudspeakers:20 W power, diam. 10 cm, springs for easy fastening.

Flush mounted stereo amplifier:it amplifies the stereo signal on the BUS and drives up to two loudspeakers with impedance between 8 and 16 OHMs. The front of the amplifier includes two pushbuttons, used to switch the loudspeakers on/off (short pressure);�� adjust the output volume (extended pressure);�� switch audio source;�� cycle through the saved radio stations.

Radio Tuner:it’s capable of receiving FM radio stations. The front pushbuttons and the backlit display give the possibility of adjusting the device, store radio stations in the memory, display RDS messages and the tuned frequency. The radio is fitted with an internal wire antenna. In case of insufficient signal inside the building, a coaxial type connection may be used. For the programming procedure see the CD supplied.

PLAnIMETRy FOR THE POSITIOnIng OF THE DEvICES

DEvICE OPERATIOn DESCRIPTIOn

Studio

Living Room

Hallway

Bathroom

Kitchen

Second bathroom Child

bedroom

Bedroom

Hallway

Legend of symbols:

Distribution board

BUS - SCS cable Audio cableAmplifier RCA input Loudspeaker

Flush mounted stereo amplifier

Flush mounting RCA input

Status notification LED

Sensitivity LED

WWW.BTICInO.COM

Page 62: Bt Digital Solutions

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

ON

OFF

5

4 4 4

6 6 6

12

3

78

BUSON

OFF

ON

OFF

ON

OFF

62

FUnCTIOnAL DIAgRAM

The configuration of the devices is performed by fitting special components called configurators in appropriate sockets identified by a number, letter, colour, or graphic symbols.To configure the devices refer to the FUnCTIOnAL DIAgRAM.

WARNING: the devices must only be configured when the system is not powered.

NOTE: the reference code for the configurators is sold in kits of 10 pieces

COnFIgURATIOn OF THE DEvICES

Description of the confi gurators

Confi gurator socket

Confi gurator

Pull-out handle

Multichannel matrix

RCA input (*)

Line terminatorLine terminator

Power supply

LIvIng ROOM/STUDIO BEDROOM

Loudspeaker

Radio Tuner

In/out wiring

OUT1 OUT2

WARnIng(*): If the sound source connected to the RCA input is not battery powered, the source insulator must be used (item 3495 BTicino, item 573988 Legrand).

A = 1MEM = 2

S = 2

Loudspeaker Loudspeaker

vacS1 S2 BUS

A = 1PF = 2

A = 1PF = 1

A = 2PF = 1

Page 63: Bt Digital Solutions

THE SOLUTIONS 63

LIST OF DEvICES THAT MUST BE ORDERED

Description q.tyResidential series items

Livinglight Axolute Arteor Céliane

4 Flush mounting amplifier 3 L4562 H4562 573976 67302

1 module Diffusion functions

key cover3

n4911BFn

nT4911BFn

L4911BFn

HD4911BF

HC4911BF

HS4911BF

573966 (right)

573967 (right)

68263 (right)

68563 (right)

Key cover On-OFF regulation

1 module3

n4911AIn

nT4911AIn

L4911AIn

HD4911AI

HC4911AI

HS4911AI

573964 (right)

573965 (right)

68264 (right)

68564 (right)

5 RCA input 1

n4560

nT4560

L4560

HD4560

HC4560

HS4560

573926

573927

67301 (dispositivo)

68261 (cover)

68561 (cover)

6 False ceiling mounted loudspeakers 6 L4566/10 L4566/10 573982 573982

7 BUS - SCS cable 1 336904 336904 573999 573999

8 Line terminator 2 3499 3499 3589 3589

Configurator 1 1 3501/1 3501/1 49201 49201Configurator 2 1 3501/2 3501/2 49202 49202Pull-out handle 1 3502 3502 49265 49265

Ring 3 - - -68083

68383

Description q.ty BTicino Legrand Size(DIn)

1 Power supply 230 vac 1 346000 63435 8 modules

1 Power supply 127 vac 1 346001 573990 8 modules

2 Multichannel matrix 1 F441M 03584 10 modules

3 Radio Tuner 1 F500n 03582 4 modules

TOTAL SIZE 22 modules

List of flush mounted devices

List of DIn module devices

nOTE: - LIvIngLIgHT: white device Tech colour device anthracite device - AXOLUTE: white device Tech colour device anthracite device - ARTEOR: white device Magnesium colour device - Céliane: white device Titanium colour device WARNING: flush mounted or wall mounted boxes, supports, and front cover plates must be ordered separately (see specific catalogue).

WWW.BTICInO.COM

Page 64: Bt Digital Solutions

ON

OFF

BUS

PRI

035 67PRI: 220 – 240 V~ 185 – 175 mA 47/63 Hz

SCS: 27 Vdc 600 mA

SCS

64

PRESETTIng OF SySTEM AnD TRACIng OF THE COnDUITS

WIRIng AnD ACTIvATIOn OF THE DEvICES

110

1)

Flush mounted amplifier for the management of the sound source and RCA input device.

Amplifier

Rear view

BUS

160 1)

Apartment switchboard

NOTE 1): recommended height

Power supply, multichannel matrix, and radio FM tuner

Power supplyMultichannel matrix

Radio Tuner FM

S1

Page 65: Bt Digital Solutions

A

THE SOLUTIONS 65

�� Quickly press and release the “M” pushbutton for the selection of the position number where the station will be stored.

�� The display shows the position where the station will be saved (A).

�� Press the forward/back pushbuttons to tune the radio to the desired frequency.

�� When changing the frequency, the number displayed will start flashing, to indicate that the frequency currently displayed is different from the stored frequency.

�� Once the desired station has been found, press and hold the “M” pushbutton until the two LEDs start flashing.

�� Release the pushbutton. The radio station has now been saved.

�� To save other stations repeat the same procedure.

The device gives the possibility of storing up to 10 radio stations. As a rule, when the tuner is supplied no radio stations are stored.

Procedure for storing radio stations

WWW.BTICInO.COM

Page 66: Bt Digital Solutions

Guida alla progettazione e all’installazione

GU

IDA

TECN

ICA

2012

MH1

2GT

- Edi

zione

01/

2012

BTic

ino

S.p.

A. si

rise

rva

il diri

tto d

i var

iare

in q

ualsi

asi m

omen

to i c

onte

nuti

del p

rese

nte

stam

pato

e d

i com

unic

are,

in q

ualsi

asi f

orm

a e

mod

alità

, i ca

mbi

amen

ti ap

porta

ti.

BTicino SpAVia Messina, 3820154 Milano - Italiawww.bticino.it

Per documentazione tecnica e informazioni di carattere commerciale

OrgAnIzzAzIOne dI VendItA e cOnSulenzA tecnIcA

Numero Verde

800-837035

Servizio Preventivazione gratuito

Numero Verde

800-293000

numeri attivi dal lunedì al venerdì dalle 8.30 alle 19.00 e il sabato dalle 8.30 alle 12.30

Piemonte • Valle d’Aosta • LiguriauFFIcIO regIOnAle10098 rIVOlI (tO)c/o PrISMA 88 – c.so Susa, 242tel. Q 011/9502611Fax 011/9502666

LombardiauFFIcIO regIOnAle20154 MIlAnO Via Messina, 38tel. Q 02/3480600Fax 02/3480610

Veneto Occidentale • Trentino Alto Adige uFFIcIO regIOnAle37047 SAn BOnIFAcIO (Vr)JJ cOnSultIng Sasloc. crosaron Villabella 18c/o Soavecentertel. 045/7612497Fax 045/6104507

Veneto Orientale • Friuli Venezia GiuliauFFIcIO regIOnAle35127 cAMIn – PAdOVAVia Vigonovese, 50tel. Q 049/8993011Fax 049/8993066

Emilia Romagna • RSM • MarcheuFFIcIO regIOnAle40069 zOlA PredOSA (BO)Via nannetti, 5/Atel. Q 051/6189911Fax 051/6189999

uFFIcIO regIOnAle60019 SenIgAllIA (An)Via corvi, 18tel. Q 071/668248Fax 071/668192

Abruzzo • Molise •Puglia • BasilicatauFFIcIO regIOnAle70026 MOdugnO (BA)Via Paradiso, 33/gtel. Q 080/5352768Fax 080/5321890

Toscana • Umbria uFFIcIO regIOnAle50136 FIrenzeVia Aretina, 265/267tel. Q 055/6557219Fax 055/6557221

Lazio • Calabria • CampaniauFFIcIO regIOnAle00153 rOMAViale della Piramide cestia, 1pal. c - 4° piano - int. 15/16tel. Q 06/5783495Fax 06/5782117

uFFIcIO regIOnAle80040 S. MArIA lA BrunAtOrre del grecO (nA)Via dell’Industria, 22tel. Q 081/ 8479500 Fax 081/ 8479510

SiciliauFFIcIO regIOnAle95125 cAtAnIAVia g. Battista grassi, 17/Atel. Q 095/7178883Fax 095/7179242

Sardegna uFFIcIO regIOnAle09100 cAglIArI c/o centro commerciale I MulInIPiano Primo int. 1Via Piero della Francesca, 3località Su Planutel. Q 070/541356Fax 070/541146

MY HOME

MH

12gt

GUIDA TECNICA

ARTEOR™

Project and installation guide

Rel

ease

07_

11

ARTEOR™

ARTEOR™

ARTEORProject and installation guide

Release 07_11

Release 07_11

CÉLIANE™

Project and installation guide

Rel

ease

07_

11

CÉLIANECÉLIANE™

Project and installation guide

Release 07_11

Release 07_11

Release 07_11

Release 07_11

Numero Verde

800-293000XXX-XXXXXX

TO CUSTOMIZETO TAKE ADVANTAGE OF OUR SERVICES CALL THE TOLL FREE NUMBER

BTicino provides its customers with technical support and quotation services. The objective is to offer to our customers a competent and fast service, working with alongside them as partners capable of providing answers to their needs, and helping them to select the best solutions for their systems.

• MYHOME AUTOMATION• VIDEO DOOR ENTRY SYSTEM

Our services

CONTACT OUR CUSTOMER SUPPORT CENTRES

BTicino offers technical after sales service through authorised centres. For the conditions of the technical assistance service during the warranty period, the costs (for services not covered by the warranty), and the details of the closest CAT call this toll free number: XXX-XXXXXX or go to the “Technical Service” section of the “Professionals Portal”.www.bticino.com

For more information see our guides.

66

Page 67: Bt Digital Solutions

TO CUSTOMIZETRAINING CENTRES

Attend training courses on BTicino systems and solutions: see the training section of the website.

WEBSITE

Always keep up to date thanks to our Professionals Portal: there you will find all the relevant product news, technical sheets, videos, and activities of BTicino.

SOFTWARE E SERVIZI 67WWW.BTICINO.COM

Page 68: Bt Digital Solutions

TO CUSTOMIZEB

Tici

no S

pA r

eser

ves

at a

ny ti

me

the

righ

t to

mod

ify th

e co

nten

ts o

f thi

s bo

okle

t and

to c

omm

unic

ate,

in

any

form

and

mod

ality

, the

cha

nges

bro

ught

to th

e sa

me.

AD -

EXC

M12

SFB

/UK

- E

ditio

n 04

/201

2