Huawei Technologies Co., Ltd. Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: Email: Copyright © Huawei Technologies Co., Ltd. 2009. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any mea Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of BSC6900 UMTS V900R011C00 Parameter Reference Huawei Technologies Co., Ltd. provides customers with comprehensive technical suppo office or company headquarters. http://www.huawei.com [email protected]

BSC6900 UMTS V900R011C00SPC700 Parameter Reference

Embed Size (px)

Citation preview

BSC6900 UMTS V900R011C00 Parameter Reference

Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, ple

Huawei Technologies Co., Ltd.Address: Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website: Email:

http://www.huawei.com [email protected]

Copyright Huawei Technologies Co., Ltd. 2009. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huaw

Trademarks and Permissionsand other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders.

nd service. For any assistance, please contact our local office or company headquarters.

thout prior written consent of Huawei Technologies Co., Ltd.

respective holders.

Purpose

This document provides information about the BSC6900 parameters, including the meaning, value, and usage of the

Intended AudienceNetwork planners Field engineers System engineers Shift operators

OrganizationEach parameter is described in the following aspects. Description Parameter ID Parameter Name NE MML Command Meaning Feature ID Feature Name Value Type GUI Value Range Actual Value Range Unit Default Value Recommended Value Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration (min) Caution

Validation of Modification Impact on Radio Network Performance Introduced in Version Attribute

6900 parameters, including the meaning, value, and usage of the parameters.

ts. Remarks Simple string for identifying a parameter Full name of the parameter NEs on which the parameter is set Commands for setting the parameter, and optional/mandatory attribute of the parameter in each command Functions, functioning ways, and protocols of the parameter Relevant feature ID Features using the parameter Parameter value type Parameter value range displayed on the GUI Actual parameter value range corresponding to the GUI Value Range. For example, the GUI Value Range is 0, and the corresponding Actual Value Range is OFF. Parameter value unit Initial value provided by the system Values recommended in different scenarios Parameter impact scope, that is, objects specified when the parameter is set Relationship between this parameter and other parameters. For example, to use this parameter, you need to set related switches and parameters. Whether this parameter is read/write or read only Whether modifying the parameter value may interrupt the existing services Possible interruption scope in the case that modifying the parameter value may interrupt the existing services Possible interruption duration in the case that modifying the parameter value may interrupt the existing services Cautions to be taken during the modification

Requirements on how to validate the modification of the parameter. For example, you may need to reset the device to validate the modification. Impact of the radio parameter on the network performance Version in which this parameter is introduced Whether this parameter is a radio parameter, a transport parameter, or an equipment parameter

Parameter ID

Parameter Name

NE

MaccPageRepeatTimes

Repeat Times of Macc Paging BSC6900

AAL2PATHT

AAL2 Path Type

BSC6900

AbsTime

Specify Time

BSC6900

Ac09ToAsc

AC 0~9 to ASC mapping BSC6900

Ac10ToAsc

AC 10 to ASC mapping BSC6900

Ac11ToAsc

AC 11 to ASC mapping BSC6900

Ac12ToAsc

AC 12 to ASC mapping BSC6900

Ac13ToAsc

AC 13 to ASC mapping BSC6900

Ac14ToAsc

AC 14 to ASC mapping BSC6900

Ac15ToAsc

AC 15 to ASC mapping BSC6900

AccessServiceClass

Access service class BSC6900

ACCTHD

AC control threshold

BSC6900

ACCTHD

AC control threshold Address and control field compress

BSC6900

ACFC

BSC6900

AcIntervalOfCell

AC Restriction Interval Of Cell BSC6900 Access Class Restriction interval between Cells BSC6900

AcIntervalOfCells

AcRange

Range of restrained AC BSC6900 Range of restrained Access Class

AcRange

BSC6900

AcRestriction

AC Restriction Indicator BSC6900 Interval of DSAC Restriction

AcRstrctIntervalLen

BSC6900

AcRstrctIntervalLen

AC Restriction Interval length BSC6900 Interval length of Domain Specific Access Class Restriction

AcRstrctIntervalLen

BSC6900

AcRstrctPercent

AC Restriction Percent BSC6900

AcRstrctSwitch

AC Restriction Switch BSC6900

ACRTHD

AC restore threshold

BSC6900

ACRTHD

AC restore threshold

BSC6900

ACSW

AC control switch

BSC6900

AFSetObj

AFSetObj

BSC6900

AgpsActivateFlag

A-GPS Method Active Flag BSC6900

A-GPS AGPSAddAssDataSendF Additional Data lag Send Flag BSC6900

AGPSMethodType

A-GPS Method Type BSC6900

AGPSRECEIVERID

GPS ID

BSC6900

AGPSRECEIVERTYPE

GPS type

BSC6900

AICHPowerOffset

AICH power offset[dB] AICH transmission timing

BSC6900

AICHTxTiming

BSC6900

AID

Alarm ID

BSC6900

AID

Alarm ID

BSC6900

AID

Alarm ID

BSC6900

AID

Alarm ID

BSC6900

AID

Alarm ID

BSC6900

AIDST

Alarm Select Type

BSC6900

AlignMode

align type

BSC6900

AllBw

Bandwidth

BSC6900

AllocCodeMode

Allocate Code Mode BSC6900

ALMTP

Alarm Type

BSC6900

ALTITUDE

GPS antenna altitude

BSC6900

ALTITUDEIMP

GPS antenna altitude

BSC6900

ALVL

Alarm Severity BSC6900

ALVL

Alarm Severity BSC6900

AmntOfRpt2B

2B event retry max times BSC6900

AmntOfRpt2C

2C event retry max times BSC6900

AmntOfRpt3A

3A event retry max times BSC6900

AmntOfRpt3C

3C event retry max times BSC6900 RLC AM mode parameters selection BSC6900 QOS Switch For AMR Traffic

AmRlcCfgPara

AMRQosPerform

BSC6900

Threshold of AmrRabAbnormRelRatio AMR Call Drop Thd Ratio[%] BSC6900 Minimum Number of AMR RAB Establish AmrRabEstabAttMinNum Request of BSC6900 Threshold AMR RAB Setup AmrRabEstabSuccRatioT Successful hd Ratio[%] Minimum Number of AMR Call Release

BSC6900

AmrRabRelMinNum

BSC6900

AmrUlRateAdjTimerLen

Wait Timer For AMR Uplink Rate[ms] BSC6900

ANI

Adjacent Node ID BSC6900

ANI

Adjacent node ID BSC6900

ANI

Adjacent node ID BSC6900

ANI

Adjacent node ID BSC6900

ANM

Alarm Name

BSC6900

AntennaAltitudeMeter

Cell Antenna Altitude[m]

BSC6900

Cell Antenna AntennaAltitudeMeterImp Altitude[ft]

BSC6900

AntennaLatitudeDegree

Cell Antenna Latitude[0.000 001degree] BSC6900

Cell Antenna AntennaLatitudeDegreeS Latitude[secon ec d] BSC6900 Cell Antenna Longitude[0.00 AntennaLongitudeDegree 0001degree] BSC6900 Cell Antenna AntennaLongitudeDegree Longitude[seco Sec nd] BSC6900 Cell Antenna Opening[0.1de gree] BSC6900

AntennaOpening

AntennaOrientation

Cell Antenna Orientation[0.1 degree] BSC6900

ANTIERRFLAG

E1T1 anti-error switch BSC6900

APFlag

APFlag

BSC6900

APP

Application type

BSC6900

AppliedDirect

RAB applied direction

BSC6900

AREAFLAG

Area flag

BSC6900

AREAFLAG

Area flag

BSC6900

ARP10Priority

User_priority of Allocation/Rete ntion priority 10 BSC6900 User_priority of Allocation/Rete ntion priority 11 BSC6900 User_priority of Allocation/Rete ntion priority 12 BSC6900 User_priority of Allocation/Rete ntion priority 13 BSC6900 User_priority of Allocation/Rete ntion priority 14 BSC6900

ARP11Priority

ARP12Priority

ARP13Priority

ARP14Priority

ARP1Priority

User_priority of Allocation/Rete ntion priority 1 BSC6900 User_priority of Allocation/Rete ntion priority 2 BSC6900 User_priority of Allocation/Rete ntion priority 3 BSC6900 User_priority of Allocation/Rete ntion priority 4 BSC6900 User_priority of Allocation/Rete ntion priority 5 BSC6900 User_priority of Allocation/Rete ntion priority 6 BSC6900 User_priority of Allocation/Rete ntion priority 7 BSC6900 User_priority of Allocation/Rete ntion priority 8 BSC6900 User_priority of Allocation/Rete ntion priority 9 BSC6900

ARP2Priority

ARP3Priority

ARP4Priority

ARP5Priority

ARP6Priority

ARP7Priority

ARP8Priority

ARP9Priority

ARPRETRY

ARP packet resend times ARP packet timeout[100ms]

BSC6900

ARPTIMEOUT

BSC6900

ASS

Event Type

BSC6900

ASS

Event Type

BSC6900

ATMSN

NodeB ATM_TRANS Slot No. BSC6900 NodeB ATM_TRANS Subrack No. BSC6900 Attach/detach allowed indication BSC6900

ATMSRN

ATT

AUSTOP

Loop time[min] BSC6900

AUSTOP

Test time[min] BSC6900

AUTHMODE

Authentication Mode BSC6900

AUTHMODE

Validate mode BSC6900

AUTHMODE

Validate mode BSC6900

AUTHNAME

Validate user name

BSC6900

AUTHNAME

Validate user name

BSC6900

AUTHPWD

Validate password

BSC6900

AUTHPWD

Validate password

BSC6900

AUTHTYPE

Validate protocol type

BSC6900

AUTHTYPE

Validate protocol type

BSC6900

AUTO

Auto negotiation

BSC6900

AUTOULKSW

Auto Unlock Switch

BSC6900

AutoUnlockTime

Auto Unlock Time

BSC6900

AUTYPE

Administration unit type BSC6900

Available AvailablesignatureEndInd signature end ex index BSC6900 Available AvailablesignatureStartIn signature start dex index BSC6900 Available AvailableSubchannelCtrl subchannel Word control word

BSC6900

AvailCap

Capability of CN Node

BSC6900

AVOL

Alarm level

BSC6900

B1B2SDTHRD

B1B2 signal degraded threshold

BSC6900

B1B2SFTHRD

B1B2 signal fail threshold B3 signal degrade threshold

BSC6900

B3SDTHRD

BSC6900

B3SFTHRD

B3 signal fail threshold Switch of backplane LINE1 Switch of backplane LINE2

BSC6900

BACK8KCLKSW1

BSC6900

BACK8KCLKSW2

BSC6900

BackgroundNoise

Background noise

BSC6900

BackupPath

Backup Path

BSC6900

BACKUPPATH

Path of Backup File BSC6900

BAKIP

Backup port IP address BSC6900

BAKMASK

Backup port mask

BSC6900

BandInd

Band indicator BSC6900

BandInd

Inter-RAT cell frequency band indicator BSC6900

BandInd

Band indicator BSC6900

BandWidthForFACH

Bandwidth of Fach

BSC6900

BCC

BS color code BSC6900 Inter-RAT cell frequency number BSC6900

BcchArfcn

BcchHspdschPower

BCCH HSPDSCH power BSC6900

BcchHsscchPower

BCCH HSSCCH power

BSC6900

BCHPower

BCH transmit power[0.1dB]

BSC6900

BEARTYPE

DSP bear type BSC6900

BearType

Bear Type

BSC6900

BeatDectThred

HeatBeat Lost Times Threshold BSC6900 HeatBeat Recover Times Threshold BSC6900

BeatRecvrThred

BeatSendingDis

HeatBeat Sending Time Interval BSC6900 BE service handover rate threshold[kbit/s ] BSC6900

BeBitRateThd

BE CPC to E_FACH BeCpc2EFachStateTrans Transition Timer Timer[s] BE CPC to FACH BeCpc2FStateTransTime Transition r Timer[s] BE DCH to E_FACH BeD2EFachStateTransTi Transition mer Timer[s] BE DCH to FACH Transition Timer[s]

BSC6900

BSC6900

BSC6900

BeD2FStateTransTimer

BSC6900

BeDlAct1

First Action For BE Downlink QOS BSC6900 Second Action For BE Downlink QOS BSC6900 Third Action For BE Downlink QOS BSC6900 BE E-DCH To FACH State Transition Timer[s] BSC6900 BE E_FACH2CPC 4A Threshold[byte ] BSC6900

BeDlAct2

BeDlAct3

BeE2FStateTransTimer

BeEFach2CpcTvmThd

BE BeEFach2CpcTvmTimeT E_FACH2CPC oTrig 4A Time[ms] BSC6900

BeEFach2DTvmThd

BE E_FACH2D 4A Threshold[byte ] BSC6900

BE BeEFach2DTvmTimeToT E_FACH2D 4A rig Time[ms] BSC6900 BE E_FACH2HSDSCH 4A Threshold[byte BeEFach2HTvmThd ] BSC6900 BE E_FACH2HSBeEFach2HTvmTimeToT DSCH 4A rig Time[ms] BSC6900 BE F2CPC_EDCH 4A Threshold[byte ] BSC6900

BeF2CpcETvmThd

BE FACH2CPC_E BeF2CpcETvmTimeToTri -DCH 4A g Time[ms] BSC6900 BE F2CPC_HSDSCH 4A Threshold[byte ] BSC6900

BeF2CpcHTvmThd

BE F2CPC_HSBeF2CpcHTvmTimeToTri DSCH 4A g Time[ms]

BSC6900

BeF2DTvmThd

BE F/R2D 4A Threshold[byte ] BSC6900

BeF2DTvmTimeToTrig

BE F/R2D 4A Time[ms]

BSC6900

BeF2ETvmThd

BE F2E-DCH 4A Threshold[byte ] BSC6900

BeF2ETvmTimeToTrig

BE F2E-DCH 4A Time[ms]

BSC6900

BeF2HTvmThd

BE F2HSDSCH 4A Threshold[byte ] BSC6900 BE F2HSDSCH 4A Time[ms]

BeF2HTvmTimeToTrig

BSC6900

BeF2PStateTransTimer

BE FACH or E_FACH to PCH Transition Timer[s] BSC6900

BE HSPA to E_FACH BeH2EFachStateTransTi Transition mer Timer[s]

BSC6900

BeH2FStateTransTimer

BE HS-DSCH to FACH Transition Timer[s] BSC6900 BE HSDSCH2F 4B Pending Time[ms]

BeH2FTvmPTAT

BSC6900

BeH2FTvmThd

BE HSDSCH2F 4B Threshold[byte ] BSC6900 BE HSDSCH2F 4B Time[ms]

BeH2FTvmTimeToTrig

BSC6900

Rate threshold of BE on 2ms TTI of BeHsupa2msTtiRateThs HSUPA[kbit/s] BSC6900 Timer For BE Inter Iur Rate[s]

BEInterIurRateUpTimer

BSC6900

BePwrMargin

BE Event F Reporting Power Margin[0.1dB] BSC6900

BEQosPerform

QOS Switch For BE Traffic BSC6900

BetaC

Reference BetaC

BSC6900

BetaD

Reference BetaD

BSC6900

BeUlAct1

First Action For BE Uplink QOS BSC6900 Second Action For BE Uplink QOS BSC6900 Third Action For BE Uplink QOS BSC6900 Indicator For BE Uplink QOS Event

BeUlAct2

BeUlAct3

BeUlEvTrigInd

BSC6900

BeUlQos5AMcSwitch

Measurement Of 5A Switch BSC6900

BeUlQos6A1McSwitch

Measurement Of 6A1 Switch BSC6900

BeUlQos6DMcSwitch

Measurement Of 6D Switch BSC6900 Wait Timer For BE Uplink Rate[ms] BSC6900 Detect multiplier of BFD packet Background MAC-c flow GBR

BeUlRateAdjTimerLen

BFDDETECTCOUNT

BSC6900

BGGBR

BSC6900

BGMBR

Background MAC-c flow MBR Background noise abnormal threshold Background noise update continuance Time Background noise update end time Equivalent user number threshold for background noise Background noise update start time

BSC6900

BgnAbnormalThd

BSC6900

BGNAdjustTimeLen

BSC6900

BgnEndTime

BSC6900

BGNEqUserNumThd

BSC6900

BgnStartTime

BSC6900

BGNSwitch

Auto-adaptive background noise update switch BSC6900 Background noise update trigger threshold

BgnUpdateThd

BSC6900

BLERQuality

Target value of service DCH_BLER BSC6900

BlindHoFlag

Blind handover flag Intrafrequency BSC6900

measurement report amount BlindHOIntrafreqMRAmo of blind unt handover Intrafrequency BSC6900 measurement report interval BlindHOIntrafreqMRInter of blind val HO[ms] BSC6900

BlindHOPrio

Blind handover Priority BSC6900

Blind handover BlindHOQualityCondition condition[dBm] BSC6900 1F event blind handover BlindHORSCP1FThresho trigger ld condition[dBm] BSC6900

BLKFILTERSW

Alarm switch of blinking filter BSC6900

BLKPRD

Alarm blink threshold

BSC6900

BLKSTATPRD

Observing time window of statistical alarm BSC6900 Switch of statistics blinking alarm BSC6900

BLKSTATSW

BLOREQTMR

Blocking request timer

BSC6900

BORROWDEVIP

Borrow DevIP BSC6900

BOXFLG

To Alarm Box Flag BSC6900

BRDCLASS

Board Class

BSC6900

BRDCLASS

Board Class

BSC6900

BRDCLASS

Board Class

BSC6900

BRDTYPE

Board Type

BSC6900

BRDTYPE

Board type.

BSC6900

BRDTYPE

Board type

BSC6900

BRDTYPE

Board type

BSC6900

BS

Backup Style

BSC6900

BSICVerify

BSIC verify switch

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board type

BSC6900

BT

Board Type

BSC6900

BT

Board type

BSC6900

BT

Board Type

BSC6900

BT

Board type

BSC6900

BT

Board Type

BSC6900

BUNDLINGFLAG

Bundling Flag BSC6900 Auto adjust bandwidth switch Backward congestion remain bandwidth Backward congestion clear remain bandwidth Backward congestion clear remain ratio

BWADJ

BSC6900

BWDCONGBW

BSC6900

BWDCONGCLRBW

BSC6900

BWDCONGCLRTH

BSC6900

BWDCONGTH

Backward congestion remain ratio Backward

BSC6900

overload congestion clear remain BWDOVLDCLRRSVBW bandwidth Backward overload congestion clear remain ratio Backward overload congestion remain bandwidth Backward overload congestion remain ratio

BSC6900

BWDOVLDCLRTH

BSC6900

BWDOVLDRSVBW

BSC6900

BWDOVLDTH

BSC6900

BWDRESVHOTH

Backward handover reserved ratio BSC6900 Backward handover reserved bandwidth

BWDRSVHOBW

BSC6900

BWMAXRATIO

Max bandwidth estimate ratio [%] BSC6900

BWMODE

Bandwidth Mode Load Control algorithm BandWidth THD[%]

BSC6900

BWRTPTH

BSC6900

CacSwitch

CAC algorithm switch BSC6900

CallShockCtrlSwitch

Call Shock Control Switch BSC6900

CallShockJudgePeriod

Call Shock Judge Period time length Indicator of Carrier Type Priority

BSC6900

CarrierTypePriorInd

BSC6900

CARRYF

Bearing subrack No.

BSC6900

CARRYFLAG

Carry Flag Bearing FRAATM link No. Bearing FRAATM link No. Bearing FRAATM link No.

BSC6900

CARRYFRAATMLNKN

BSC6900

CARRYFRAATMLNKN

BSC6900

CARRYFRAATMLNKN

BSC6900

CARRYFRAATMLNKN

FRAATM link No.

BSC6900

CARRYIMAGRPN

Bearing IMA group No.

BSC6900

CARRYIMAGRPN

Bearing IMA group No.

BSC6900

CARRYIMAGRPN

Bearing IMA group No.

BSC6900

CARRYIMAGRPN

IMA group No. BSC6900

CARRYLNKT

Bearing link type Bearing NCOPT port No. Bearing NCOPT port No. Bearing NCOPT port No.

BSC6900

CARRYNCOPTN

BSC6900

CARRYNCOPTN

BSC6900

CARRYNCOPTN

BSC6900

CARRYPN

Optical port No.

BSC6900

CARRYSN

Bearing slot No.

BSC6900

CARRYSN

Bearing slot No.

BSC6900

CARRYSRN

Bearing subrack No.

BSC6900

CARRYT

Bearing type

BSC6900

CARRYT

Bearing type

BSC6900

CARRYT

Bearing type The bearing type of the logic port

BSC6900

CARRYT

BSC6900

CARRYT

The bearing type of the logic port

BSC6900

CARRYT

Carry port type BSC6900

CARRYUNILNKN

Bearing UNI link No.

BSC6900

CARRYUNILNKN

Bearing UNI link No.

BSC6900

CARRYUNILNKN

Bearing UNI link No.

BSC6900

CARRYUNILNKN

Bearing UNI link No.

BSC6900

CARRYVCI

Bearing VCI

BSC6900

CARRYVCI

Bearing VCI

BSC6900

CARRYVPI

Bearing VPI

BSC6900

CARRYVPI

Bearing VPI

BSC6900

CARRYVPN

Bearing ATM logic port No.

BSC6900

CARRYVPN

Bearing ATM logic port No.

BSC6900

CARRYVPN

Bearing ATM logic port No.

BSC6900

CBCIPADDR

CBS CBC IP address

BSC6900

CBCMASK

Subnet mask

BSC6900

CBS

Consent burst size [Byte] BSC6900

CBSCTHD

CBS control threshold

BSC6900

CBSCTHD

CBS control threshold

BSC6900

CBSOpIndex

CBS Operator Index BSC6900

CBSRTHD

CBS restore threshold

BSC6900

CBSRTHD

CBS restore threshold

BSC6900

CBSSAC

CBS SAC

BSC6900

CBSSAC

CBS SAC

BSC6900

CBSSW

CBS flow control switch BSC6900

CBSwitch

CB Switch

BSC6900

CCAEnableSta

Certificate Chain File Enabled State BSC6900

CCCHGBR

CCCH MAC-c flow GBR BSC6900

CCCHMBR

CCCH MAC-c flow MBR BSC6900 Common channel primary path Common channel pri path load threshold Common channel secondary path

CCHPRIPATH

BSC6900

CCHPRITH

BSC6900

CCHSECPATH

BSC6900

CCHSECWHT

Common channel pri sec path load ratio threshold BSC6900

CCMINTERVAL

CCM Send Prid

BSC6900

CCTMR

Timer_CC Cell delay variation tolerance AMR_RRC Number per Second for Cell

BSC6900

CDVT

BSC6900

CellAmrRrcNum

BSC6900

CellAverageHeight

Cell Average Altitude[m]

BSC6900

CellAverageHeightImp

Cell Average Altitude[ft]

BSC6900

Cell Capability CellCapacityAutoHandle Auto Handle Switch Switch BSC6900

CellCapContainerFdd

Cell capability container BSC6900

CellCenterAltitude

Cell Center Altitude[m]

BSC6900

CellCenterAltitudeImp

Cell Center Altitude[ft]

BSC6900

CellCenterLatitude

Cell Center Latitude[0.000 001degree] BSC6900 Cell Center Latitude[secon d] BSC6900 Cell Center Longitude[0.00 0001degree] BSC6900

CellCenterLatitudeSec

CellCenterLongitude

Cell Center Longitude[seco CellCenterLongitudeSec nd] BSC6900

CellChoice

Target cell choice Cell Environment Case

BSC6900

CellEnvironment

BSC6900

CellEnvType

Cell environment type Cell Altitude Standard Deviation[m] Cell Altitude Standard Deviation[ft] HiPri_RRC Number per Second for Cell

BSC6900

CellHeightStd

BSC6900

CellHeightStdImp

BSC6900

CellHighPriRrcNum

BSC6900

CellHostType

Cell Host Type BSC6900

CellId

Cell ID

BSC6900

CellId

Cell ID

BSC6900

CellId

Cell ID

BSC6900

CellId

Cell ID

BSC6900

CellId

Cell ID

BSC6900

CellId

Cell ID Cell ID of Neighboring RNC

BSC6900

CellId

BSC6900

CellId

Cell ID Cell ID Changing Period time length Cell ID Changing Switch

BSC6900

CellIDChgPeriod

BSC6900

CellIDChgSwitch

BSC6900

CellidRttActivateFlag

CELLID+RTT Method Active Flag BSC6900

CELLID+RTT CELLIDRTTMethodType Method Type Cell LDR SF reserved threshold

BSC6900

CellLdrSfResThd

BSC6900

CellLocCfgType

Cell Location Setting Type

BSC6900

CellName

Cell name

BSC6900

CellOverrunThd

Cell overload threshold Cell Reselection Counter Threshold Cell Reselection Timer[s]

BSC6900

CellReSelectCounter

BSC6900

CellReSelectTimer

BSC6900

Cell reservation CellReservationExtension extension

BSC6900

Cell reserved CellReservedForOperator for operator Use use

BSC6900

CellsForbidden1A

Affect 1A threshold flag

BSC6900

CellsForbidden1B

Affect 1B threshold flag

BSC6900

CellTotalRrcNumThd

Cell Call Shock Trigger Threshold BSC6900

CellUnderrunThd

Cell under load threshold BSC6900 Cell URA update control threshold BSC6900 Cell URA update control threshold BSC6900 Cell URA update restore threshold BSC6900 Cell URA update restore threshold BSC6900 Cell URA update flow control switch BSC6900 Certificate Chain File Name RAC Configuration Indication

CELLURACTHD

CELLURACTHD

CELLURARTHD

CELLURARTHD

CELLURASW

CertChain

BSC6900

CfgRacInd

BSC6900

CfgRacInd

RAC Configuration Indication

BSC6900

CfgSwitch

Channel configuration strategy switch BSC6900

CFM

Confirm Password

BSC6900

CG

Command Group

BSC6900

CG

Command Group

BSC6900

CGN

Command Group Name

BSC6900

Channel Retry ChannelRetryHoTimerLe Ho Timer n Length[s] BSC6900 Channel Retry Timer Length[s] BSC6900

ChannelRetryTimerLen

ChCodingType

Channel code type BSC6900 Ping Check Timeout Counts

CHECKCOUNT

BSC6900

ChIdx

Channel Index BSC6900

CHKN

Check Index

BSC6900

CHKN

Check Index Calculate checksum when receive message Calculate checksum when send message

BSC6900

CHKSUMRX

BSC6900

CHKSUMTX

BSC6900

CHKSUMTYPE

Checksum arithmetic

BSC6900

CHKTYPE

Check type

BSC6900

Time unit for ChoiceRprtUnitForDlBasi DL basic meas cMeas rprt cycle BSC6900 Time unit for ChoiceRprtUnitForDlOlc DL OLC meas Meas rprt cycle BSC6900 Time unit of HSDPA need ChoiceRprtUnitForHsdpa pwr meas PwrMeas cycle

BSC6900

Time unit of ChoiceRprtUnitForHsdpa HSDPA bit rate RateMeas meas cycle BSC6900 Time unit of ChoiceRprtUnitForHsupa HSUPA bit rate RateMeas meas cycle BSC6900 Time unit for ChoiceRprtUnitForUlBasi UL basic meas cMeas rprt cycle BSC6900 Time unit for ChoiceRprtUnitForUlOlc UL OLC meas Meas rprt cycle BSC6900

ChoiceRptUnitForAmrE

AMR Reporting Period Unit For Event E BSC6900 BE Reporting Period Unit For Event E BSC6900 BE Reporting Period Unit For Event F BSC6900 VP Reporting Period Unit For Event E BSC6900

ChoiceRptUnitForBeE

ChoiceRptUnitForBeF

ChoiceRptUnitForVpE

ChSwitch

Channel Switch

BSC6900

CID

GSM cell ID

BSC6900

CIO

Cell oriented Cell Individual Offset[dB] BSC6900

CIO

Cell Individual Offset[dB] BSC6900 Cell oriented Cell Individual Offset[0.5dB] BSC6900 Neighboring cell oriented CIO[dB] Neighboring cell oriented CIO[dB]

CIO

CIOOffset

BSC6900

CIOOffset

BSC6900

CIR

Bandwidth [64kbps]

BSC6900

CLEARTHD

Error clear threshold

BSC6900

CLKTYPE

Clock board type

BSC6900

CLRFLG

Alarm Cleared Flag BSC6900 Closed loop time adjust mode indication Compression mode capability

CLTAModeInd

BSC6900

CmCap

BSC6900

CmcfCellType

CM cell type CMCF algorithm switch

BSC6900

CmcfSwitch

BSC6900

CmchRsrcRspTmr

CMCH RSRC response timer[ms] BSC6900

CMD

Command Name

BSC6900

CMD

Command Name

BSC6900

CMDSEQ

Command Sequence

BSC6900

CmpSwitch

Compatibility switch

BSC6900

CN

Cabinet No.

BSC6900

CNDomainId

CN domain ID BSC6900

CNDomainId

CN domain ID BSC6900

CNDomainId

CN domain ID BSC6900

CNId

CN node ID

BSC6900

CNLoadStatus

Status of CN Node Resource Management Mode

BSC6900

CNMNGMODE

BSC6900

CNOPERATORINDEX

Operator Index BSC6900

CNOPERATORINDEX

Cn Operator Index

BSC6900

CnOperatorName

Cn Operator Name

BSC6900

CnOpGrpIndex

Cn Operator Group Index

BSC6900

CnOpGrpIndex

CN Operator Group Index

BSC6900

CnOpGrpIndex

CN Operator Group Index

BSC6900

CnOpGrpName

Cn Operator Group Name

BSC6900

CNOPINDEX

CN Operator index

BSC6900

CnOpIndex

Cn Operator Index

BSC6900

CnOpIndex

Cn Operator Index

BSC6900

CnOpIndex

CN Operator index

BSC6900

CNOPINDEX

CN operator index

BSC6900

CnOpIndex1

Operator 1 Index

BSC6900

CnOpIndex2

Operator 2 Index

BSC6900

CnOpIndex3

Operator 3 Index

BSC6900

CnOpIndex4

Operator 4 Index

BSC6900

CnOpIndexComm

Common Operator Index BSC6900

CnOpNum

Operator Number

BSC6900

CNProtclVer

CN protocol version

BSC6900

CNT

Records to Return

BSC6900

CNTL

Counts Limit Upper count threshold of raised fault Lower count threshold of raised fault

BSC6900

CNTRISTHRD

BSC6900

CNTSTLTHRD

BSC6900

Code Adjust Switch for CodeAdjForHsdpaSwitch HSDPA

BSC6900

User Number for Code CodeAdjForHsdpaUserN Adjust for umThd HSDPA Code occupied BSC6900 rate threshold for code CodeBalancingDrdCode balancing RateThd drd[%] BSC6900 Code occupied rate threshold CodeBalancingDrdCode for code RateThd balance drd[%] BSC6900 Minimum SF threshold for CodeBalancingDrdMinSF code balance Thd drd Minimum SF threshold for CodeBalancingDrdMinSF code balance Thd drd

BSC6900

BSC6900

Code balance CodeBalancingDrdSwitch DRD switch BSC6900

Code balance CodeBalancingDrdSwitch drd switch BSC6900 Code congestion CodeCongSelInterFreqH select interoInd freq indication BSC6900

CodeScheme

Code Scheme BSC6900

CodingRate

CoexistMeasThdChoice

InterFreq and Coding rate InterRat coexist measure threshold choice

BSC6900

BSC6900

CombNCellPercent

Combine Neighbour Cell Percent[%] BSC6900 Comb Event F Reporting Power Margin[0.1dB] BSC6900

CombPwrMargin

2G Cell Load CommonMeasurementPe Measurement riod Report Period BSC6900

CommPlmnUsingType

Comm Plmn Using Type

BSC6900

Complicacy

Password Complexity

BSC6900

COMTMR1

Timer T1

BSC6900

COMTMR2

Timer T2

BSC6900

COMTMR3

Timer T3 Recover threshold of queue 0 [ms] Recover threshold of queue 1 [ms] Recover threshold of queue 2 [ms] Recover threshold of queue 3 [ms] Recover threshold of queue 4 [ms] Recover threshold of queue 5 [ms] Congestion threshold of queue 0 [ms] Congestion threshold of queue 1 [ms] Congestion threshold of queue 2 [ms] Congestion threshold of queue 3 [ms]

BSC6900

CONGCLRTHD0

BSC6900

CONGCLRTHD1

BSC6900

CONGCLRTHD2

BSC6900

CONGCLRTHD3

BSC6900

CONGCLRTHD4

BSC6900

CONGCLRTHD5

BSC6900

CONGTHD0

BSC6900

CONGTHD1

BSC6900

CONGTHD2

BSC6900

CONGTHD3

BSC6900

CONGTHD4

Congestion threshold of queue 4 [ms] Congestion threshold of queue 5 [ms] Cell barred indicator for SIB4

BSC6900

CONGTHD5

BSC6900

ConnCellBarred

BSC6900

ConnectFailRrcRedirSwit RRC redirect ch switch

BSC6900

Intra-freq cell ConnIntraFreqReselectio reselection ind n for SIB4 BSC6900 Connect power monitoring board BSC6900 Hysteresis 1 for connect mode[2dB] Hysteresis 2 for connect mode[2dB]

CONNPWR

ConnQhyst1s

BSC6900

ConnQhyst2s

BSC6900

ConnQoffset1sn

ConnQoffset1s n[dB] BSC6900

ConnQoffset2sn

ConnQoffset2s n[dB] Inter-freq cell BSC6900 reselection threshold for connect mode[2dB] Intra-freq cell reselection threshold for connect mode[2dB]

ConnSintersearch

BSC6900

ConnSintrasearch

BSC6900

ConnTbarred

Time barred for SIB4

BSC6900

CONNTYPE

Connection Type

BSC6900

Constantvalue

Constant value for calculating initial TX power[dB] BSC6900

CONTPING

Continue ping or not BSC6900 Downlink MBR of Conversation[k bit/s] BSC6900 Uplink MBR of Conversation[k bit/s] BSC6900 Conversational MAC-c flow GBR BSC6900 Conversational MAC-c flow MBR BSC6900 Max Mode Of Narrowband AMRC For Copper Users BSC6900 Max Mode Of Wideband AMRC For Copper Users BSC6900

ConverDlMBR

ConverUlMBR

CONVGBR

CONVMBR

CopperMaxMode

CopperMaxMode

Count

Send PKT Count

BSC6900

CountCThreshold

Count-C threshold

BSC6900

CounterCheckSwitch

Counter check switch BSC6900

CP1SupInd

CP1 support indicator

BSC6900

CP1SupInd

CP1 support indicator Call page control threshold Call page restore threshold CPUS traffic share threshold

BSC6900

CPAGECTHD

BSC6900

CPAGERTHD

BSC6900

CPUSShareThd

BSC6900

CqiDtxTimer

CQI Activity Timer[subfram e] BSC6900

CQI Feedback CQIFbCkinInDTXDRXmo Cycke in DTXde DRX mode[ms] BSC6900 Certificate Revocation List File Name BSC6900 Certificate Revocation List File State BSC6900

CRL

CRLEnableSta

CRMaxNum

Max number of cell reselection BSC6900 Cross IP address available flag

CROSSIPFLAG

BSC6900

CRRCCONNCCPUTHD

Call RRC conn share CPU control threshold BSC6900

Call RRC conn share msg control CRRCCONNCMSGTHD threshold BSC6900 Call RRC conn share CPU restore threshold BSC6900

CRRCCONNRCPUTHD

Call RRC conn share msg restore CRRCCONNRMSGTHD threshold BSC6900 UMTS R99 CS conversational service downlink factor BSC6900 R99 CS conversational primary path BSC6900 R99 CS conversational pri path load threshold BSC6900 R99 CS conversational secondary path CS BSC6900 R99 conversational pri sec path load ratio threshold BSC6900 UMTS R99 CS conversational service uplink factor BSC6900

CSCONVDL

CSCONVPRIPATH

CSCONVPRITH

CSCONVSECPATH

CSCONVSECWHT

CSCONVUL

CsErlang

Voice ErlangErlang CS domain Reloc GSM load THD

BSC6900

CSHOOut2GloadThd

BSC6900

CsInfoUpdFlag

CS Information Update Switch BSC6900 CS Information Update Protection Timer BSC6900 Feature Supporting Mode of CS Domain

CsInfoUpdTmr

CsNriCfgMode

BSC6900

CSNRILength

Length of CS NRI in bits

BSC6900

CsRestriction

Restriction for CS BSC6900

CsRestriction

Restriction for CS BSC6900 Inter-RAT CS handover switch

CSServiceHOSwitch

BSC6900

CSSTRMDL

UMTS R99 CS streaming service downlink factor BSC6900 R99 CS streaming primary path R99 CS streaming pri path load threshold R99 CS streaming secondary path

CSSTRMPRIPATH

BSC6900

CSSTRMPRITH

BSC6900

CSSTRMSECPATH

BSC6900

CSSTRMSECWHT

R99 CS streaming pri sec path load ratio threshold BSC6900

CSSTRMUL

UMTS R99 CS streaming service uplink factor BSC6900

CsSwitch

CS algorithm switch

BSC6900

CSVoiceChlType

CS voice channel type

BSC6900

CS Voice Hspa Dl Relative CSVoiceHspaDlRelDelay Delay[ms] BSC6900 CS Voice Hspa Ul Relative CSVoiceHspaUlRelDelay Delay[ms] BSC6900 HSUPA TTI type of CS voice traffic

CSVoiceHsupaTti

BSC6900

H2D procedure before reloc CSVoiceOverHspaSuppI when nd CsOverHspa BSC6900 Self-healing Switch for Ethernet Adapter Traffic Monitoring BSC6900 Calculated transport format combination

CSW

CTFC

BSC6900

CTFCSize

CTFC length of TFCS[bit] BSC6900

CTFCSize

CTFC length of TFCS[bit] BSC6900

CTHD

Critical threshold

BSC6900

CTHD

Critical threshold

BSC6900

Control plane sharing out CtrlPlnSharingOutOffset offset Control plane sharing out threshold

BSC6900

CtrlPlnSharingOutThd

BSC6900

CTRLSLOT

Slot No.

BSC6900

CTRLSW

CM Control Enable Switch BSC6900

CXT

Cross type

BSC6900

CZ

Classified Zone ID

BSC6900

D2F2PTvmThd

BE D2F/R Or F/R2P 4B Threshold[byte ] BSC6900 BE D2F/R 4B Pending Time[ms]

D2FTvmPTAT

BSC6900

D2FTvmTimeToTrig

BE D2F/R 4B Time[ms]

BSC6900

DATE

Date Limit

BSC6900

DATE

Date

BSC6900

Dccc1APenaltyTime

1A Rate Down Penalty Time Length[s] BSC6900 Period of penalty timer for SHO failure after down rate[s] BSC6900

DcccShoPenaltyTime

DcccStg

DCCC Strategy

BSC6900

DcccUpPenaltyLen

DCCC Rate Up Fail Penalty Time Length[s] BSC6900 DCH Throu Meas Period[10ms]

DchThrouMeasPeriod

BSC6900

Period Amount DchThrouPendingTime4 after trigger 4B B on DCH BSC6900 Period Amount DchThrouTimetoTrigger4 to trigger 4B B on DCH BSC6900

DefaultCnOp

Default CnOperator

BSC6900

DefaultConstantValue

Constant value configured by default[dB] BSC6900

DefPcpichEcNo

Default PCPICH Ec/No BSC6900

DELAY

Max diff delay[ms]

BSC6900

Delay

Delay Time Length

BSC6900

DelayClass

Delay Class

BSC6900

DelayClass

Delay Class

BSC6900

Delta code occupied DeltaCodeOccupiedRate rate[%]

BSC6900

DeltaQrxlevmin

Delta Min Rx level

BSC6900

DeltaQrxlevmin

Delta Min Rx level

BSC6900

DENO

Destination entity No.

BSC6900

DESC

Description

BSC6900

DESTIP

Destination IP address BSC6900

DESTIP

Destination IP address BSC6900

DESTIP

Destination IP address BSC6900

DESTMEPID

RMEP ID Borrowed device IP address

BSC6900

DEVIP

BSC6900

DEVTYPE

Device IP Address Type BSC6900 The Type of FTP Server Command Port BSC6900 DGPS data report period[min]

DFTPORTSWT

DGPSPERIOD

BSC6900

DHCP Relay Gateway IP DHCPRLYGATEWAYIP Address

BSC6900

DHCPRLYID

DHCP Relay ID

BSC6900

DINM

Date in Month BSC6900

DINW

Date in Week

BSC6900

DIR

Directory

BSC6900

Direction

DivCtrlField

Direction Softer handover combination indication switch

BSC6900

BSC6900

DlAmrConvAF

DL AF of R99 AMR conv service BSC6900 AMR Trigger Time Of Event E[ms] BSC6900

DlAmrTrigTimeE

DlBackgroundAF

DL AF of R99 background service BSC6900

DL basic common DlBasicCommMeasFilter measure filter Coeff coeff BSC6900 DL rate of HSDPA BE traffic as H2D[kbit/s]

DlBeH2DInitialRate

BSC6900

DlBeTraffDecThs

DL BE traffic DCH decision threshold[kbit/s ] BSC6900 DL BE traffic DCH decision threshold[kbit/s ] BSC6900 DL BE traffic Initial bit rate[kbit/s]

DlBeTraffDecThs

DlBeTraffInitBitrate

BSC6900

DlBeTraffThsOnHsdpa

DL BE traffic threshold on HSDPA[kbit/s] BSC6900 BE Trigger Time Of Event E[ms] BSC6900 BE Trigger Time Of Event F[ms] BSC6900 DL CAC smoothing filter length BSC6900 DL common channel load reserved coefficient

DlBeTrigTimeE

DlBeTrigTimeF

DlCacAvgFilterLen

DlCCHLoadRsrvCoeff

BSC6900

DlCellTotalThd

DL total power threshold BSC6900

DlCmMethod

Downlink Compression Method

BSC6900

DLCODENO

Reserved DL code No

BSC6900

DlConvAMRThd

DL threshold of Conv AMR service BSC6900 DL threshold of Conv non_AMR service BSC6900

DlConvNonAMRThd

DL CS should DlCSInterRatShouldBeH be HO user OUeNum number BSC6900 DL CS should DlCSInterRatShouldBeH be ho user OUeNum number BSC6900 DL CS should DlCSInterRatShouldNotH not be HO user OUeNum number BSC6900 DL CS should DlCSInterRatShouldNotH not be ho user OUeNum number BSC6900 Downlink Bit Rate Threshold For DCCC[kbit/s] BSC6900 Downlink Full Coverage Bit Rate[kbit/s]

DlDcccRateThd

DlFullCvrRate

BSC6900

DlGBR

Downlink GBR for BE service[kbit/s] BSC6900 DL handover credit and code reserved SF BSC6900

DlHoCeCodeResvSf

DlHOThd

DL handover access threshold

BSC6900

DlHSUPARsvdFactor

Dl HSUPA reserved factor BSC6900 DL AF of R99 interactive service BSC6900 DL HO maximum bandwidth

DlInteractAF

DlInterFreqHoBWThd

BSC6900

DL HO load DlInterFreqHoCellLoadSp space aceThd threshold

BSC6900

DL LDR-AMR DlLdrAMRRateReduction rate reduction RabNum RAB number BSC6900 DL LDR smoothing filter length BSC6900

DlLdrAvgFilterLen

DL LDR-BE DlLdrBERateReductionR rate reduction abNum RAB number BSC6900 DL LDR-BE DlLdrBERateReductionR rate reduction abNum RAB number BSC6900 Dl LDR credit SF reserved threshold

DlLdrCreditSfResThd

BSC6900

DlLdrCreditSfResThd

Dl LDR Credit SF reserved threshold BSC6900

DlLdrEighthAction

DL LDR eighth action BSC6900

DlLdrFifthAction

DL LDR fifth action

BSC6900

DlLdrFifthAction

DL LDR fifth action

BSC6900

DlLdrFirstAction

DL LDR first action

BSC6900

DlLdrFirstAction

DL LDR first action

BSC6900

DlLdrFourthAction

DL LDR fourth action BSC6900

DlLdrFourthAction

DL LDR fourth action BSC6900

DlLdrNinthAction

DL LDR ninth action

BSC6900

DL LDR un-ctrl DlLdrPsRTQosRenegRa RT Qos rebNum nego RAB num BSC6900 DL LDR un-ctrl DlLdrPsRTQosRenegRa RT Qos rebNum nego RAB num BSC6900 DL LDR release threshold

DlLdrRelThd

BSC6900

DlLdrSecondAction

DL LDR second action BSC6900

DlLdrSecondAction

DL LDR second action BSC6900

DlLdrSeventhAction

DL LDR seventh action BSC6900

DlLdrSixthAction

DL LDR sixth action

BSC6900

DlLdrSixthAction

DL LDR Sixth action BSC6900

DlLdrTenthAction

DL LDR tenth action BSC6900

DlLdrThirdAction

DL LDR third action

BSC6900

DlLdrThirdAction

DL LDR third action

BSC6900

DlLdrTrigThd

DL LDR trigger threshold BSC6900 DL State Trans Hysteresis threshold BSC6900 Downlink Maximum Number of TFC

DlLdTrnsHysTime

DlMaxNumOfTfc

BSC6900

DlMBMSRsvdFactor

DL MBMS reserved factor BSC6900 DL TCP Measurement Filter Coefficient BSC6900 Downlink Mid Bit Rate Calculate Method

DlMeasFilterCoef

DlMidRateCalc

BSC6900

DlMidRateThd

Downlink Mid Bit Rate Threshold[kbit/ s] BSC6900

DL Mode Change Waiting Timer DlModeChangeTimerLen Length[ms] BSC6900 DL Mode Change Waiting Timer DlModeChangeTimerLen Length[ms] BSC6900 DL AF of R99 non AMR conv service BSC6900 DL OLC smoothing filter length BSC6900

DlNonAmrConvAF

DlOlcAvgFilterLen

DL OLC fast TF restrict RAB DlOlcFTFRstrctRabNum number BSC6900 DL OLC fast TF restrict times

DlOlcFTFRstrctTimes

BSC6900

DlOlcMeasFilterCoeff

DL overload measure filter coeff BSC6900 DL OLC release threshold DL OLC traff release RAB number

DlOlcRelThd

BSC6900

DlOlcTraffRelRabNum

BSC6900

DlOlcTrigHyst

DL OLC trigger hysteresis[10m s] BSC6900

DlOlcTrigThd

DL OLC trigger threshold BSC6900

DlOtherThd

DL threshold of other services BSC6900

DLOVSFSF

Reserved DL code OVSF

BSC6900

DL PS should DlPSInterRatShouldBeH be HO user OUeNum number BSC6900 DL PS should DlPSInterRatShouldBeH be ho user OUeNum number BSC6900 DL PS should DlPSInterRatShouldNotH not be HO user OUeNum number BSC6900 DL PS should DlPSInterRatShouldNotH not be ho user OUeNum number BSC6900 Switch Of AMR Downlink Rate Adjustment BSC6900

DlQosAmrAdjSwitch

InterFreq HO DlQosAmrInterFreqHoSw Switch For itch Downlink AMR BSC6900 InterRat HO DlQosAmrInterRatHoSwit Switch For ch Downlink AMR BSC6900 Down Link Qos Measure timer length[s] BSC6900

DLQosMcTimerLen

InterFreq HO DlQosVpInterFreqHoSwit Switch For ch Downlink VP

BSC6900

DlQosWAmrAdjSwitch

Switch For WAMR Downlink Rate BSC6900

InterFreq HO Switch For DlQosWAmrInterFreqHo WAMR Switch Downlink InterRat HO Switch For DlQosWAmrInterRatHoS WAMR witch Downlink Switch Of DL R99 Congestion Control

BSC6900

BSC6900

DlR99CongCtrlSwitch

BSC6900

DlRateDnAdjLevel

Downlink Rate Decrease Adjust Level BSC6900 Downlink Rate Increase Adjust Level BSC6900 Down Link RSCP UsedFreq THD Hyst[dB] Downlink spreading factor

DlRateUpAdjLevel

DlRscpQosHyst

BSC6900

DlSF

BSC6900

DlSFLimitCMInd

Dl SF limit CM ind BSC6900

DlSFTurnPoint

DL SF threshold

BSC6900

DlSrbActFactor

DL AF of SRB BSC6900 DL AF of R99 Streaming service BSC6900 DL streaming traffic threshold on HSDPA[kbit/s] BSC6900

DlStreamAF

DlStrThsOnHsdpa

DlThdE1

DL E1 Event Relative Threshold[0.1d B] BSC6900 DL E1 Event Relative Threshold[0.1d B] BSC6900 DL E2 Event Relative Threshold[0.1d B] BSC6900 DL E2 Event Relative Threshold[0.1d B] BSC6900 DL F1 Event Relative Threshold[0.1d B] BSC6900 DL F1 Event Relative Threshold[0.1d B] BSC6900 DL F2 Event Relative Threshold[0.1d B] BSC6900 DL F2 Event Relative Threshold[0.1d B] BSC6900 DL total equivalent user number BSC6900 VP Trigger Time Of Event E[ms] BSC6900 Expected diff delay guardband[cells]

DlThdE1

DlThdE2

DlThdE2

DlThdF1

DlThdF1

DlThdF2

DlThdF2

DlTotalEqUserNum

DlVpTrigTimeE

DLYGB

BSC6900

DomainType

Blocked domain type

BSC6900

Enable Door Status Alarm DOOR_ENGINE_MASK Reporting DSP code[Whole Number] DPCCH Transmission Burst 1[subframe] DPCCH Transmission Burst 2[subframe] prefered DPCCH slot format for HSPA DSP code[Divided Number] DPCH with MIMO priority Tx diversity mode

BSC6900

DPC

BSC6900

DpcchBurst1

BSC6900

DpcchBurst2

BSC6900

DpcchSlotFmtForHspa

BSC6900

DPCDNF

BSC6900

DpchDivModforMIMO

BSC6900

DpchDivModforMIMO

DPCH diversity mode for MIMO user BSC6900

DPCH priority DpchPrioTxDiversityMod Tx diversity e mode BSC6900 DPCH priority DpchPrioTxDiversityMod Tx diversity e mode BSC6900

DpcMode

DL power control mode

BSC6900

DPCT

DSP type

BSC6900

DPORTNO

Dst Port NO.

BSC6900

DPUSN

DPUb Slot No. BSC6900

DPX

DSP index

BSC6900

DPX

DPX Index

BSC6900

Dpx

DSP index Dynamic resource allocation switch

BSC6900

DraSwitch

BSC6900

DRDEcN0Threshhold

Drd Ec/N0 threshold[dB]

BSC6900

DRDEcN0Threshhold

Drd Ec/N0 threshold[dB]

BSC6900

DrlAal2EstIndTmr

DRL AAL2 establishment indication timer[ms] BSC6900 DRL reconfiguration commit timer[ms] BSC6900 Max inter-RAT direct retry number BSC6900 Max inter-RAT direct retry number[times] BSC6900

DrlRecfgCmitTmr

DRMaxGSMNum

DRMaxGSMNum

DrncBeDlRlcQosSwitch

Drnc Parameter for BE Downlink RLC QOS BSC6900 Packet discard threshold of queue 0 [ms] BSC6900 Packet discard threshold of queue 1 [ms] BSC6900 Packet discard threshold of queue 2 [ms] BSC6900 Packet discard threshold of queue 3 [ms] BSC6900 Packet discard threshold of queue 4 [ms] BSC6900 Packet discard threshold of queue 5 [ms] BSC6900

DROPPKTTHD0

DROPPKTTHD1

DROPPKTTHD2

DROPPKTTHD3

DROPPKTTHD4

DROPPKTTHD5

DrSwitch

Direct retry switch

BSC6900

DrxCycle

DRX Cycle[subfram e] BSC6900 DRX cycle length coefficient Paging DRX cycle coefficient

DRXCycleLenCoef

BSC6900

DrxCycleLenCoef

BSC6900

DrxGrantMonitoring

UE DRX Grant Monitoring Decision BSC6900

Drxvalid

DRX Parameter Switch

BSC6900

DS1

E1T1 port No. BSC6900

DS1

E1T1 port No. BSC6900

DsacAutoSwitch

Switch for auto DSAC BSC6900 Differentiated Service Codepoint

DSCP

BSC6900

DSCP

Differentiated services code point BSC6900 Differentiated Service Codepoint

DSCP

BSC6900

DSPN

DSP No.

BSC6900

DSPNO

Dsp No.

BSC6900

DST

DaylightSave

BSC6900

DSTIP

Destination IP address BSC6900

DSTMASK

Destination address mask BSC6900

DSTPORTNO

Destination port No.

BSC6900

DSTTSMASK

Destination timeslot mask BSC6900 DPCCH Transmission Cycle 1[subframe] DPCCH Transmission Cycle 2[subframe] delay time of DTX_DRX in action

DtxCycle1

BSC6900

DtxCycle2

BSC6900

DtxDrxEnablingDelay

BSC6900

DtxLongPreamble

Long DPCCH Preamble[slot] BSC6900 DTX Parameter Switch Timer Period

Dtxvalid

BSC6900

Length For Cell Dynamic DynCellOpenJudgeTimerl ShutDown en feature Timer Protect Length For Cell Dynamic DynCellShutdownProtect ShutDown Timerlen feature Cell Dynamic ShutDown Switch For DynCellShutDownSwitch RNC Cell Dynamic ShutDown Switch Cell Dynamic ShutDown Type

BSC6900

BSC6900

BSC6900

DynShutdownSwitch

BSC6900

DynShutDownType

BSC6900

E1T1PN

Bearing port No.

BSC6900

E1T1PN

E1/T1 port No. BSC6900 E-DCH Throu Meas Period[10ms] BSC6900 E-DCH2F 4B Pending Period Amount BSC6900 E-DCH2F 4B Threshold[kbit/ s] BSC6900

E2FThrouMeasPeriod

E2FThrouPTAT

E2FThrouThd

E2FThrouTimeToTrig

E-DCH2F 4B Period Amount BSC6900

EagchCodeNum

Code Number for E-AGCH BSC6900

ECHOIP

Check IP address

BSC6900

EcN0AdjStep

Ec/N0 Adjustment Step[0.001dB] BSC6900 Ec/N0 Adjustment Measurement Period[10ms] BSC6900

EcN0AdjTimerLen

EcN0EffectTime

Ec/N0 effective time[ms] BSC6900

EcN0EffectTime

Ec/N0 effective time[ms] BSC6900

EcN0MaxDownAdjStep

Maximum Ec/N0 Down Step[0.001dB] BSC6900 Maximum Ec/N0 Up Step[0.001dB] BSC6900

EcN0MaxUpAdjStep

EcN0Ths

Ec/N0 threshold[dB]

BSC6900

EcN0Ths

Ec/N0 threshold[dB]

BSC6900

ECSN

End Serial No. BSC6900

ED

End Date

BSC6900

ED

End Date

BSC6900

ED

End Date

BSC6900

EDAY

End date

BSC6900

EdchMacdPduSize1

E-DCH MAC-D PDU size1[bit] BSC6900 E-DCH MAC-D PDU size10[bit] BSC6900 E-DCH MAC-D PDU size11[bit] BSC6900

EdchMacdPduSize10

EdchMacdPduSize11

EdchMacdPduSize12

E-DCH MAC-D PDU size12[bit] BSC6900

EdchMacdPduSize2

E-DCH MAC-D PDU size2[bit] BSC6900

EdchMacdPduSize3

E-DCH MAC-D PDU size3[bit] BSC6900

EdchMacdPduSize4

E-DCH MAC-D PDU size4[bit] BSC6900

EdchMacdPduSize5

E-DCH MAC-D PDU size5[bit] BSC6900

EdchMacdPduSize6

E-DCH MAC-D PDU size6[bit] BSC6900

EdchMacdPduSize7

E-DCH MAC-D PDU size7[bit] BSC6900

EdchMacdPduSize8

E-DCH MAC-D PDU size8[bit] BSC6900

EdchMacdPduSize9

E-DCH MAC-D PDU size9[bit] BSC6900 The Number of E-DCH MAC-D PDU Size BSC6900 Period Amount after trigger 4A on EDCH BSC6900 Period Amount after trigger 4B on EDCH BSC6900

EdchMacdPduSizeNum

EdchPendingTime4A

EdchPendingTime4B

EdchRateAdjustSet

HSUPA UpLink Rate Adjust Set

BSC6900

EdchSirMaxDownStep

Maximum EDCH SIR decrease step[0.001dB] BSC6900 Edch Target

Large Number of E-DCH PDU EdchTargetLargeRetrans retransfer[time Num s] BSC6900 Edch Little Target Number of E-DCH PDU EdchTargetLittleRetrans retransfer[time Num s] BSC6900 Period Amount to trigger 4A on EDCH BSC6900 Period Amount to trigger 4B on EDCH BSC6900

EdchTimetoTrigger4A

EdchTimetoTrigger4B

EdchTtiType

Edch TTI type BSC6900 UMTS EFACH channel forward factor BSC6900

EFACHDL

EFACHDTCHGBP

EFACH DTCH GBP BSC6900

EFachSupInd

EFachSupInd BSC6900 switch for RRC established on E_FACH BSC6900

EFachSwitch

CM permission EHSPACMPermissionInd ind on HSPA+ BSC6900

EM

EndType

BSC6900

EmcPreeRefVulnSwitch

Preemptvulner ability for Emergency call switch BSC6900

EMERGENCY

Emergency verification

BSC6900

EmergLCSSwitch

Emergency LCS Switch

BSC6900

EMITTHD

Error emit threshold

BSC6900

EMONTH

End month

BSC6900

EMSIP

EMS IP Address Transport Encrypted Mode

BSC6900

ENCRYMODE

BSC6900

ENCRYMODE

The Encrypted Mode BSC6900

EncryptionAlgo

Encryption algorithm

BSC6900

ENDAID

EndTime1

End Alarm ID First Cell Dynamic ShutDown Interval End Time

BSC6900

BSC6900

EndTime2

Second Cell Dynamic ShutDown Interval End Time Cell Third Dynamic ShutDown Interval End Time

BSC6900

EndTime3

BSC6900

ENF

Status

BSC6900

ENF

Subtask Status BSC6900

ENTITYT

Local entity type

BSC6900

ENTITYT

Destination entity type

BSC6900

ERCODE

Return Code

BSC6900

ErgchEhichCodeNum

Code Number for E-RGCH/EHICH BSC6900 Error-frame alarm threshold

ERRALARMTHD

BSC6900

ERRDETECTSW

Error-frame detect switch

BSC6900

ESSN

End Sync Serial No.

BSC6900

ESTINDTMR

Establishment indication timer BSC6900

ESTREQTMR

Establishment request timer BSC6900

ET

EndTime

BSC6900

ET

End Time

BSC6900

ET

End Time

BSC6900

ET

Execute Type BSC6900

ET

End Time

BSC6900

ET

End Time

BSC6900

ET

End Time

BSC6900

ETD

End Date

BSC6900

ETP

Log Type

BSC6900

ETT

End Time

BSC6900

Event4aThd

Traffic Measurement Event 4A threshold[byte] BSC6900

Event4bThd

Traffic Measurement Event 4B threshold[byte] BSC6900

EventAReportDelay

Event A report delay[10ms] BSC6900 Event A threshold[0.1% ] BSC6900 Event B threshold[0.1% ] BSC6900

EventAThred

EventBThred

EWEEK

End week

BSC6900

EWSEQ

End week sequence

BSC6900

EX_ANO1_SIG_MAX

Upper Limit of Signal Output of External Analog 1 BSC6900 Lower Limit of Signal Output of External Analog 1 BSC6900 Sensor Type of External AnalogLimit of BSC6900 Upper 1 Measurement Range of External AnalogLimit of BSC6900 Lower 1 Measurement Range of External Analog 1 BSC6900 Upper Limit of Signal Output of External Analog 2 BSC6900

EX_ANO1_SIG_MIN

EX_ANO1_TYPE

EX_ANO1_VAL_MAX

EX_ANO1_VAL_MIN

EX_ANO2_SIG_MAX

EX_ANO2_SIG_MIN

Lower Limit of Signal Output of External Analog 2 BSC6900 Sensor Type of External AnalogLimit of BSC6900 Upper 2 Measurement Range of External AnalogLimit of BSC6900 Lower 2 Measurement Range of External Analog 2 BSC6900 Upper Limit of Signal Output of External Analog 3 BSC6900 Lower Limit of Signal Output of External Analog 3 BSC6900 Sensor Type of External AnalogLimit of BSC6900 Upper 3 Measurement Range of External AnalogLimit of BSC6900 Lower 3 Measurement Range of External Analog 3 BSC6900 Upper Limit of Signal Output of External Analog 4 BSC6900 Lower Limit of Signal Output of External Analog 4 BSC6900 Sensor Type of External Analog 4 BSC6900

EX_ANO2_TYPE

EX_ANO2_VAL_MAX

EX_ANO2_VAL_MIN

EX_ANO3_SIG_MAX

EX_ANO3_SIG_MIN

EX_ANO3_TYPE

EX_ANO3_VAL_MAX

EX_ANO3_VAL_MIN

EX_ANO4_SIG_MAX

EX_ANO4_SIG_MIN

EX_ANO4_TYPE

EX_ANO4_VAL_MAX

Upper Limit of Measurement Range of External AnalogLimit of BSC6900 Lower 4 Measurement Range of External Analog 4 BSC6900 BE F2P 4B Pending Time[ms]

EX_ANO4_VAL_MIN

F2PTvmPTAT

BSC6900

F2PTvmTimeToTrig

BE F2P 4B Time[ms]

BSC6900

FachId

FACH ID

BSC6900

FachIdforMcch

FACH ID for MCCH

BSC6900

FachMaxPower

Fach Max Power[dB]

BSC6900

FachMaxPower

Fach Max Power[0.1dB]

BSC6900

FachMaxPower

Fach Max Power[dB]

BSC6900

FACHMeasInd

FACH Meas Indicator

BSC6900

FACHPwrReduceValue

Fach power reduce value

BSC6900

FACTOR

SPI Factor[%] BSC6900

FACTOR

Factor

BSC6900

FailTimeTh

DCCC Rate Up Fail Time Threshold BSC6900

Continuous FANADJUSTCOMMAND adjustment 0 command Discrete FANADJUSTCOMMAND adjustment 1 command Duty ratio FANADJUSTCOMMAND adjustment 2 command Fan adjustment mode

BSC6900

BSC6900

BSC6900

FANADJUSTMODE

BSC6900

FANFLAG

Fan Type Speed adjustment mode

BSC6900

FANSPEEDMODE

BSC6900

FANTYPE

FanBox Type

BSC6900

FC

Physical layer flow control switch BSC6900 Flow control parameter index Flow control parameter index

FCINDEX

BSC6900

FCINDEX

BSC6900

FCINDEX

Flow control parameter index Flow control parameter index Flow control parameter index Flow control parameter index Flow control parameter index Flow control parameter index Flow control parameter index Flow control parameter index Flow control parameter index

BSC6900

FCINDEX

BSC6900

FCINDEX

BSC6900

FCINDEX

BSC6900

FCINDEX

BSC6900

FCINDEX

BSC6900

FCINDEX

BSC6900

FCINDEX

BSC6900

FCINDEX

BSC6900

FCSTYPE

CRC check mode

BSC6900

FCSTYPE

CRC check mode

BSC6900

FCSW

Flow control switch

BSC6900

FddTpcDlStepSize

FDD DL power control step size[dB] BSC6900 Fdpch with MIMO priority Tx diversity mode

FdpchDivModforMIMO

BSC6900

FdpchDivModforMIMO

FDPCH diversity mode for MIMO user BSC6900

Fdpch without MIMO priority FdpchDivModforNonMIM Tx diversity O mode BSC6900 FDPCH diversity mode FdpchDivModforNonMIM for non MIMO O user BSC6900 FDPCH maximum reference power FDPCH minimum reference power

FdpchMaxRefPwr

BSC6900

FdpchMinRefPwr

BSC6900

FdpchPO2

F-DPCH Power Offset[0.25dB] BSC6900 Fast judgement window

FDWINDOW

BSC6900

FILE

File Name

BSC6900

FILE

Target File Path

BSC6900

FileName

File Name

BSC6900

FILEPATH

Export File Path

BSC6900

FILETYPE

Log File Type BSC6900

FilterCoef

Intra-freq meas L3 filter coeff BSC6900

FilterCoefOf2D2F

2D2F filter coeff

BSC6900

FIN

Final

BSC6900

FixedMachsWinSize

Fixed MAC-hs window size BSC6900

FlcAlgoSwitch

Flc Algo Switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FLOWCTRLSWITCH

Flow control switch

BSC6900

FN

File Name

BSC6900

FN

File Name

BSC6900

FN

File Name

BSC6900

FN

File Name

BSC6900

FN

File Name ForcedSho Switch In CELLID+RTT Method Maximum Delay Time[ms]

BSC6900

ForcedSHOSwitch

BSC6900

FPTIMER

BSC6900

FRAGSIZE

MP flake size

BSC6900

FRALNKN

Fractional link No. BSC6900

FRALNKT

Fractional link type BSC6900

FREQ

Time Mode

BSC6900

FREQ

Time Mode

BSC6900

FRMLEN

TX frame length

BSC6900

FT

File Type

BSC6900

FTI

Factor table index

BSC6900

FTI

Factor table index

BSC6900

FUNCTIONSWITCH1

Function Switch1

BSC6900

FUNCTIONSWITCH2

Function Switch2

BSC6900

FUNCTIONSWITCH3

Function Switch3

BSC6900

FUNCTIONSWITCH4

Function Switch4

BSC6900

FUNCTIONSWITCH5

Function Switch5 Forward congestion remain bandwidth Forward congestion clear remain bandwidth Forward congestion clear remain ratio Forward congestion remain ratio Forward overload congestion clear remain bandwidth Forward overload congestion clear remain ratio Forward overload congestion remain bandwidth Forward overload congestion remain ratio

BSC6900

FWDCONGBW

BSC6900

FWDCONGCLRBW

BSC6900

FWDCONGCLRTH

BSC6900

FWDCONGTH

BSC6900

FWDOVLDCLRRSVBW

BSC6900

FWDOVLDCLRTH

BSC6900

FWDOVLDRSVBW

BSC6900

FWDOVLDTH

BSC6900

FWDRESVHOTH

Forward handover reserved ratio BSC6900 Forward handover reserved bandwidth

FWDRSVHOBW

BSC6900

GainFactorBetaC

Gain Factor BetaC

BSC6900

GainFactorBetaD

Gain Factor BetaD

BSC6900

GCDF

GCDF

BSC6900

GCDF

Geocoordinate data format UMTS general BSC6900 common channel service downlink factor BSC6900 UMTS general common channel service uplink factor BSC6900 Global route management switch

GENCCHDL

GENCCHUL

GLOBALROUTESW

BSC6900

GoldMaxMode

Max Mode Of Narrowband AMRC For Golden Users BSC6900 Max Mode Of Wideband AMRC For Golden Users BSC6900

GoldMaxMode

GoldUserLoadControlSwi Gold user load tch control switch BSC6900

GPSPERIOD

GPS data report period Transport Resource Group No.

BSC6900

GRPID

BSC6900

GRPT

Transport Resource Group Type

BSC6900

GSMCellIndex

GSM cell index BSC6900

GSMCellName

GSM cell name ICMP type which will be guarded Handover control threshold Handover control threshold Handover restore threshold Handover restore threshold

BSC6900

GUARDTYPE

BSC6900

HANDOVERCTHD

BSC6900

HANDOVERCTHD

BSC6900

HANDOVERRTHD

BSC6900

HANDOVERRTHD

BSC6900

HANDOVERSW

Handover flow control switch BSC6900

HangBlockNum5A

Interval Block Number

BSC6900

HappyBR

Happy bit rate[kbit/s] HARQ Preamble capability indication

BSC6900

HarqPreaCap

BSC6900

HBDelaycnd

Happy bit delay time[ms] BSC6900

HBINTER

Heartbeat interval

BSC6900

HCARRYT

High bearing type

BSC6900

Punish Timer Length for HCodeAdjPunshTimerLe Code Adjust ngth for HSDPA

BSC6900

HCSPrio

HCS priority level

BSC6900

HCSPrio

HCS priority level

BSC6900

HDBKGDL

UMTS HSDPA background service downlink factor BSC6900 HSDPA background primary path

HDBKGPRIPATH

BSC6900

HDBKGPRITH

HSDPA background pri path load threshold BSC6900 HSDPA background secondary path

HDBKGSECPATH

BSC6900

HDBKGSECWHT

HSDPA background pri sec path load ratio threshold BSC6900 UMTS HSDPA conversational service downlink factor BSC6900

HDCONVDL

HDCONVPRIPATH

HSDPA conversational primary path BSC6900 HSDPA conversational pri path load threshold BSC6900 HSDPA conversational secondary path BSC6900 HSDPA conversational pri sec path load ratio threshold BSC6900

HDCONVPRITH

HDCONVSECPATH

HDCONVSECWHT

HSDPA high interactive pri HDHIGHINTERACTPRIT path load H threshold HSDPA high pri sec path HDHIGHINTERACTSEC load ratio WHT threshold

BSC6900

BSC6900

HDINTERDL

UMTS HSDPA interactive service downlink factor BSC6900 HSDPA high PRI interactive primary path BSC6900 HSDPA high PRI interactive secondary path BSC6900 HSDPA low PRI interactive primary path BSC6900 HSDPA low PRI interactive secondary path BSC6900 HSDPA middle PRI interactive primary path BSC6900

HDINTHGHPRIPATH

HDINTHGHSECPATH

HDINTLOWPRIPATH

HDINTLOWSECPATH

HDINTMIDPRIPATH

HDINTMIDSECPATH

HSDPA middle PRI interactive secondary path BSC6900

HSDPA low interactive pri HDLOWINTERACTPRIT path load H threshold

BSC6900

HSDPA low interactive pri HDLOWINTERACTSEC sec path load WHT ratio threshold BSC6900 HSDPA mid interactive pri path load HDMIDINTERACTPRITH threshold

BSC6900

HSDPA mid interactive pri HDMIDINTERACTSECW sec path load HT ratio threshold BSC6900 UMTS HSDPA IMS signal downlink factor BSC6900 HSDPA IMS Signal primary path BSC6900 HSDPA IMS Signal pri path load threshold BSC6900 HSDPA IMS Signal secondary path

HDSIPDL

HDSIPPRIPATH

HDSIPPRITH

HDSIPSECPATH

BSC6900

HDSIPSECWHT

HSDPA IMS Signal pri sec path load ratio threshold BSC6900 UMTS HSDPA signal downlink factor BSC6900

HDSRBDL

HDSRBPRIPATH

HSDPA Signal primary path BSC6900

HDSRBPRITH

HSDPA Signal pri path load threshold BSC6900 HSDPA Signal secondary path BSC6900 HSDPA Signal pri sec path load ratio threshold BSC6900 UMTS HSDPA streaming service downlink factor BSC6900 HSDPA streaming primary path HSDPA streaming pri path load threshold HSDPA streaming secondary path

HDSRBSECPATH

HDSRBSECWHT

HDSTRMDL

HDSTRMPRIPATH

BSC6900

HDSTRMPRITH

BSC6900

HDSTRMSECPATH

BSC6900

HDSTRMSECWHT

HSDPA streaming pri sec path load ratio threshold BSC6900 UMTS HSDPA voice service downlink factor BSC6900

HDVOICEDL

HDVOICEPRIPATH

HSDPA Voice primary path BSC6900 HSDPA Voice secondary path BSC6900

HDVOICESECPATH

HFRAATMLNKN

High FRAATM link No. BSC6900

HhoRelocProcSwitch

Relocation with HHO process switch BSC6900

HHOTRIG

HHO cross IUR trigger

BSC6900

HIMAGRPN

High IMA group No. HO active set update response timer[ms]

BSC6900

HoAsuTmr

BSC6900

HoCellUpdateRspTmr

HO cell update response timer[ms] of BSC6900 The priority coverage based interfrequency handover HO paging response timer[ms]

HOCovPrio

BSC6900

HoPagingRspTmr

BSC6900

HoPhychRecfgTmr

HO PhyCh reconfiguration timer[ms] BSC6900 HO relocation request timer[ms] BSC6900

HoRelocReqTmr

HostType

NodeB Host Type

BSC6900

HoSwitch

HandOver switch Inter-freq

BSC6900

HOThdEcN0

measure target frequency trigger Ec/No THD[dB] BSC6900

HOThdRscp

Inter-freq measure target frequency trigger RSCP THD[dBm] BSC6900 HO wait timer for TrCh or RB reconfiguration response[ms] BSC6900

HoWtTrchRecfgRspTmr

HPN

High NCOPT port No. AF of hsdpa background service HSDPA best effort PBR threshold

BSC6900

HsdpaBackGroundAF

BSC6900

HsdpaBePBRThd

BSC6900

CM permission HsdpaCMPermissionInd ind on HSDPA BSC6900

HsdpaConvAF

AF of hsdpa conv service AF of hsdpa interactive service

BSC6900

HsdpaInteractAF

BSC6900

HSDPA need HsdpaNeedPwrFilterLen power filter len BSC6900

HsdpaPrvidBitRateFilterL HSDPA bit rate en filter len BSC6900 Minimum Number of HSDPA RAB Establish HsdpaRabEstAttMinNum Request of BSC6900 Threshold HSDPA RAB Setup HsdpaRabEstSuccRatioT Successful hd Ratio[%]

BSC6900

HsdpaStreamAF

AF of hsdpa streaming service

BSC6900

HsdpaStrmPBRThd

Hsdpa streaming PBR threshold BSC6900 HSDPA Throughput1KBPS Cell Dynamic ShutDown Hsdpa User number Threshold HS-DSCH MAC-D PDU size1[bit] HS-DSCH MAC-D PDU size2[bit] HS-DSCH MAC-D PDU size3[bit] HS-DSCH MAC-D PDU size4[bit] HS-DSCH MAC-D PDU size5[bit] HS-DSCH MAC-D PDU size6[bit] HS-DSCH MAC-D PDU size7[bit] HS-DSCH MAC-D PDU size8[bit]

HSDPAthroughput

BSC6900

HsdpaUserNumThd

BSC6900

HsdschMacdPduSize1

BSC6900

HsdschMacdPduSize2

BSC6900

HsdschMacdPduSize3

BSC6900

HsdschMacdPduSize4

BSC6900

HsdschMacdPduSize5

BSC6900

HsdschMacdPduSize6

BSC6900

HsdschMacdPduSize7

BSC6900

HsdschMacdPduSize8

BSC6900

The Number of HS-DSCH HsdschMacdPduSizeNu MAC-D PDU m Size BSC6900

HSN

High slot No.

BSC6900

HspaEnhSwitch

Cell Hspa Enhanced function switch BSC6900 prefered HSPA PLUS character BSC6900

HSPAPlusSelection

HspaPlusSwitch

Cell Hspa Plus function switch BSC6900 The Offset of HSPA Total Power[0.1dB]

HspaPower

BSC6900

HspaTimerLen

HSPA hysteresis timer length[s] BSC6900

Support HspdcchSecondCodeSup second code p1 Flag for Tb1 Support HspdcchSecondCodeSup second code p2 Flag for Tb2 Support HspdcchSecondCodeSup second code p3 Flag for Tb3 Support HspdcchSecondCodeSup second code p4 Flag for Tb4

BSC6900

BSC6900

BSC6900

BSC6900

HsPdschCodeNum

Code Number for HS-PDSCH BSC6900

HsPdschMaxCodeNum

Code Max Number for HS-PDSCH Code Min Number for HS-PDSCH HS-PDSCH MPO Constant[dB]

BSC6900

HsPdschMinCodeNum

BSC6900

HsPdschMPOConstEnu m

BSC6900

Hspdsch HspdschPrioTxDiversityM priority Tx ode diversity mode BSC6900 Hspdsch HspdschPrioTxDiversityM priority Tx ode diversity mode BSC6900

HSRN

High subrack No.

BSC6900

HsScchCodeNum

Code Number for HS-SCCH BSC6900

HSUPA TTI 10ms schedule Hsupa10msSchPrdForGr period with ant grant[ms] BSC6900 HSUPA TTI 10ms schedule Hsupa10msSchPrdForNo period without nGrant grant[ms] BSC6900 HSUPA TTI 2ms schedule Hsupa2msSchPrdForGra period with nt grant[ms] BSC6900 HSUPA TTI 2ms schedule Hsupa2msSchPrdForNon period without Grant grant[ms] BSC6900 AF of hsupa background service

HsupaBackGroundAF

BSC6900

HsupaBeShoRateThd

HSUPA BE SHO THD RATE[kbit/s]

BSC6900

HsupaCeConsumeSelecti HSUPA Credit on Consume Type BSC6900

CM permission HsupaCMPermissionInd ind on HSUPA BSC6900

HsupaConvAF

AF of hsupa conv service

BSC6900

HsupaDcccStg

HSUPA DCCC Strategy BSC6900

Equal priority HsupaEqualPriorityUserP HSUPA user BRThd PBR threshold BSC6900 High priority HsupaHighPriorityUserP HSUPA user BRThd PBR threshold BSC6900 Initial rate of HSUPA BE traffic[kbit/s] AF of hsupa interactive service

HsupaInitialRate

BSC6900

HsupaInteractAF

BSC6900

Low priority HsupaLowPriorityUserPB HSUPA user RThd PBR threshold BSC6900

HsupaPrvidBitRateFilterL HSUPA bit rate en filter len BSC6900 Minimum Number of HSUPA RAB Establish HsupaRabEstAttMinNum Request BSC6900

Threshold of HSUPA RAB Setup HsupaRabEstSuccRatioT Successful hd Ratio[%] AF of hsupa streaming service HSUPA Throughput1KBPS

BSC6900

HsupaStreamAF

BSC6900

HSUPAthroughput

BSC6900

HSUPA auto retransmit load release HsupAuRetrnsLdRelThd threshold BSC6900 HSUPA auto retransmit load trigger HsupAuRetrnsLdTrigThd threshold Cell Dynamic BSC6900 ShutDown Hsupa User number Threshold HSUPA background primary path

HsupaUserNumThd

BSC6900

HUBKGPRIPATH

BSC6900

HUBKGPRITH

HSUPA background pri path load threshold BSC6900 HSUPA background secondary path

HUBKGSECPATH

BSC6900

HUBKGSECWHT

HSUPA background pri sec path load ratio threshold BSC6900 UMTS HSUPA background service uplink factor BSC6900 HSUPA conversational primary path BSC6900

HUBKGUL

HUCONVPRIPATH

HUCONVPRITH

HSUPA conversational pri path load threshold BSC6900 HSUPA conversational secondary path BSC6900 HSUPA conversational pri sec path load ratio threshold BSC6900 UMTS HSUPA conversational service uplink factor BSC6900

HUCONVSECPATH

HUCONVSECWHT

HUCONVUL

HSUPA high interactive pri HUHIGHINTERACTPRIT path load H threshold

BSC6900

HSUPA high interactive pri HUHIGHINTERACTSEC sec path load WHT ratio threshold BSC6900 UMTS HSUPA interactive service uplink factor BSC6900 HSUPA high PRI interactive primary path BSC6900 HSUPA high PRI interactive secondary path BSC6900 HSUPA low PRI interactive primary path BSC6900 HSUPA low PRI interactive secondary path BSC6900 HSUPA middle PRI interactive primary path BSC6900

HUINTERUL

HUINTHGHPRIPATH

HUINTHGHSECPATH

HUINTLOWPRIPATH

HUINTLOWSECPATH

HUINTMIDPRIPATH

HUINTMIDSECPATH

HSUPA middle PRI interactive secondary path BSC6900

HSUPA low interactive pri HULOWINTERACTPRIT path load H threshold

BSC6900

HSUPA low interactive pri HULOWINTERACTSEC sec path load WHT ratio threshold BSC6900 Enable Humidity Alarm Reporting BSC6900

HUM_MASK

HUM_THD_HIGH

Upper Limit of Humidity Alarm BSC6900

HUM_THD_LOW

Lower Limit of Humidity Alarm BSC6900

HSUPA mid interactive pri path load HUMIDINTERACTPRITH threshold

BSC6900

HSUPA mid interactive pri HUMIDINTERACTSECW sec path load HT ratio threshold BSC6900

HUNILNKN

High UNI link No.

BSC6900

HUSIPPRIPATH

HSUPA IMS Signal primary path BSC6900 HSUPA IMS Signal pri path load threshold BSC6900 HSUPA IMS Signal secondary path

HUSIPPRITH

HUSIPSECPATH

BSC6900

HUSIPSECWHT

HSUPA IMS Signal pri sec path load ratio threshold BSC6900 UMTS HSUPA IMS signal uplink factor BSC6900

HUSIPUL

HUSRBPRIPATH

HSUPA Signal primary path BSC6900 HSUPA Signal pri path load threshold BSC6900 HSUPA Signal secondary path BSC6900 HSUPA Signal pri sec path load ratio threshold BSC6900 UMTS HSUPA signal uplink factor BSC6900 HSUPA streaming primary path HSUPA streaming pri path load threshold HSUPA streaming secondary path

HUSRBPRITH

HUSRBSECPATH

HUSRBSECWHT

HUSRBUL

HUSTRMPRIPATH

BSC6900

HUSTRMPRITH

BSC6900

HUSTRMSECPATH

BSC6900

HUSTRMSECWHT

HSUPA streaming pri sec path load ratio threshold BSC6900 UMTS HSUPA streaming service uplink factor BSC6900

HUSTRMUL

HUVOICEPRIPATH

HSUPA Voice primary path BSC6900 HSUPA Voice secondary path BSC6900 UMTS HSUPA voice service uplink factor BSC6900

HUVOICESECPATH

HUVOICEUL

HVCI

High VCI

BSC6900

HVPI

High VPI

BSC6900

HystFor1A

1A hysteresis[0.5d B] BSC6900 1B hysteresis[0.5d B] BSC6900 1C hysteresis[0.5d B] BSC6900 1D hysteresis[0.5d B] BSC6900 1F hysteresis[0.5d B] BSC6900 1J hysteresis[0.5d B] BSC6900 2B hysteresis[0.5d B] BSC6900

HystFor1B

HystFor1C

HystFor1D

HystFor1F

HystFor1J

HystFor2B

Hystfor2C

2C hysteresis[0.5d B] BSC6900 2D hysteresis[0.5d B] BSC6900 2D hysteresis[0.5d B] BSC6900 2F hysteresis[0.5d B] BSC6900 2F hysteresis[0.5d B] BSC6900 3A hysteresis[0.5d B] BSC6900 3C hysteresis[0.5d B] BSC6900 Inter-RAT hysteresis[0.5d B] BSC6900 HHO hysteresis[0.5d B] BSC6900

HystFor2D

Hystfor2D

HystFor2F

Hystfor2F

Hystfor3A

Hystfor3C

HystforInterRAT

HystForPrdInterFreq

IARXTMR

Inactive RX timer

BSC6900

IATXTMR

Inactive TX timer

BSC6900

ICMPPKGLEN

ICMP packet Length

BSC6900

ID

Task ID

BSC6900

ID

Task ID Cell barred indicator for SIB3

BSC6900

IdleCellBarred

BSC6900

Intra-freq cell reselection ind IdleIntraFreqReselection for SIB3 BSC6900 Hysteresis 1 for idle mode[2dB] Hysteresis 2 for idle mode[2dB]

IdleQhyst1s

BSC6900

IdleQhyst2s

BSC6900

IdleQoffset1sn

IdleQoffset1sn[ dB] BSC6900

IdleQoffset2sn

IdleQoffset2sn[ dB] BSC6900 Inter-freq cell reselection threshold for idle mode[2dB] BSC6900 Intra-freq cell reselection threshold for idle mode[2dB] BSC6900

IdleSintersearch

IdleSintrasearch

IdleTbarred

Time barred for SIB3

BSC6900

IDLETMR

Timer_Idle

BSC6900

The timer length of anti pingpong NCOV IFAntiPingpangTimerLen interfreq gth handover[s]

BSC6900

IgorTmr

TigOR[ms]

BSC6900

IMAGRPN

IMA group No. BSC6900

IMAGRPN

IMA group No. BSC6900

IMAID

IMA ID

BSC6900

IMALNKN

IMA link No.

BSC6900

IMAVER

IMA protocol version

BSC6900

Ims Bear enhanced ImsBearEnhancedSwitch switch

BSC6900

ImsChlType

IMS channel type

BSC6900

IMSGBR

IMS MAC-c flow GBR

BSC6900

ImsiMax

The end of IMSI

BSC6900

ImsiMin

The start of IMSI

BSC6900

ImsInitialAccessRate

Ims initial rate[kbit/s] Maximum of IMSI route parameter in IDNNS Minimum of IMSI route parameter in IDNNS

BSC6900

ImsiRtMax

BSC6900

ImsiRtMin

BSC6900

IMSMBR

IMS MAC-c flow MBR For BSC6900 Threshold DPCCH Transmission Cycle 2[EDCH TTI] BSC6900 DRX Inactivity Threshold[subf rame] BSC6900 Inactivity

InactThsForCycle2

InactThsForDrxCycle

Threshold for UE Grant InactThsForGrantMonitori Monitoring[ED ng CH TTI] BSC6900

INFRA_RED_MASK

Infrared alarm switch BSC6900

INHTMR

Timer_NOCREDIT Integrity protection algorithm Interactive MAC-c flow GBR Interactive MAC-c flow MBR

BSC6900

IntegrityProtectAlgo

BSC6900

INTERACTGBR

BSC6900

INTERACTMBR

BSC6900

InterFreqActiveType

MBDR switch BSC6900 Inter-freq measure target frequency InterFreqCovHOThdEcN trigger Ec/No 0 THD[dB] BSC6900 Inter-freq CS measure start Ec/No InterFreqCSThd2DEcN0 THD[dB] BSC6900 Inter-freq CS measure start RSCP InterFreqCSThd2DRSCP THD[dBm] BSC6900 Inter-freq CS measure stop Ec/No InterFreqCSThd2FEcN0 THD[dB] BSC6900 Inter-freq CS measure stop RSCP InterFreqCSThd2FRSCP THD[dBm] BSC6900

InterFreqDlMbdrTrigThre shold DL theshold

BSC6900

InterFreqFilterCoef

Inter-frequency measure filter coeff BSC6900 Inter-freq handover type switch BSC6900 Inter-freq H measure start Ec/No THD[dB] BSC6900 Inter-freq H measure start RSCP THD[dBm] BSC6900 Inter-freq H measure stop Ec/No THD[dB] BSC6900

InterFreqHOSwitch

InterFreqHThd2DEcN0

InterFreqHThd2DRSCP

InterFreqHThd2FEcN0

InterFreqHThd2FRSCP

Inter-freq H measure stop RSCP THD[dBm] BSC6900

Inter-freq and Inter-RAT Meas Ctrl Info InterFreqInterRatMeasInd Ind BSC6900 Inter-freq Measure Quantity

InterFreqMeasQuantity

BSC6900

InterFreqMeasTime

Inter-freq measure timer length[s] BSC6900 Inter-freq measure timer length[s] BSC6900 Inter-

InterFreqMeasTime

Frequency Neighboring InterFreqNCellDetectSwit Cell Detect ch Switch Inter-freq

BSC6900

measure target frequency InterFreqNCovHOThdEc trigger Ec/No N0 THD[dB] BSC6900 Inter-freq R99 PS measure InterFreqR99PsThd2DEc start Ec/No N0 THD[dB] BSC6900 Inter-freq R99 PS measure InterFreqR99PsThd2DRS start RSCP CP THD[dBm] BSC6900 Inter-freq R99 PS measure InterFreqR99PsThd2FEc stop Ec/No N0 THD[dB] BSC6900 Inter-freq R99 PS measure InterFreqR99PsThd2FRS stop RSCP CP THD[dBm] BSC6900 Inter-freq and Inter-RAT coexist switch BSC6900

InterFreqRATSwitch

InterFreqReportMode

Inter-frequency measure report mode BSC6900 Inter-frequency measure report mode BSC6900

InterFreqReportMode

Inter-freqency scaling factor InterFreqTreselScalingFa for reselection ctor delay BSC6900

InterFreqUlMbdrTrigThre shold UL theshold

BSC6900

Inter RAT Inter InterPlmnHoAllowedInter Plmn Ho Rat Allowed BSC6900 Intra RAT Inter InterPlmnHoAllowedIntra Plmn Ho Rat Allowed BSC6900

InterRatActiveType

MBDR switch

BSC6900

Inter-RAT CS measure start Ec/No InterRATCSThd2DEcN0 THD[dB] BSC6900 Inter-RAT CS measure start RSCP InterRATCSThd2DRSCP THD[dBm] BSC6900 Inter-RAT CS measure stop Ec/No InterRATCSThd2FEcN0 THD[dB] BSC6900 Inter-RAT CS measure stop RSCP InterRATCSThd2FRSCP THD[dBm] BSC6900

InterRatDlMbdrTrigThres hold DL theshold

BSC6900

InterRATFilterCoef

Inter-RAT filter coeff BSC6900 Inter-RAT handover max attempt times BSC6900 Emergency LCS Inter-Rat Handover Permit BSC6900 Inter-RAT CS handover decision THD[dBm] Inter-Rat Handover Type

InterRATHOAttempts

InterRatHOPermit

InterRATHOThd

BSC6900

InterRatHOType

BSC6900

InterRATHThd2DEcN0

Inter-RAT H measure start Ec/No THD[dB] BSC6900 Inter-RAT H measure start RSCP THD[dBm] BSC6900 Inter-RAT H measure stop Ec/No THD[dB] BSC6900 Inter-RAT H measure stop RSCP THD[dBm] BSC6900 Inter-RAT measure timer length[s] BSC6900 Inter-RAT measure timer length[s] BSC6900

InterRATHThd2DRSCP

InterRATHThd2FEcN0

InterRATHThd2FRSCP

InterRATMeasTime

InterRATMeasTime

Inter-Rat Neighboring InterRatNCellDetectSwitc Cell Detect h Switch

BSC6900

Inter-RAT CS handover decision InterRATNCovHOCSThd THD[dBm] Inter-RAT PS handover decision InterRATNCovHOPSThd THD[dBm] Inter-RAT InterRATPeriodReportInt period report erval interval[ms]

BSC6900

BSC6900

BSC6900

InterRatPhyChFailNum

Inter-RAT HO physical channel failure THD BSC6900 Inter-RAT PingPong Hyst[0.5dB]

InterRATPingPongHyst

BSC6900

Inter-RAT PingPong InterRATPingPongTimer timer[s]

BSC6900

Inter-RAT R99 PS measure InterRATR99PsThd2DEc start Ec/No N0 THD[dB] BSC6900 Inter-RAT R99 PS measure InterRATR99PsThd2DRS start RSCP CP THD[dBm] BSC6900 Inter-RAT R99 PS measure InterRATR99PsThd2FEc stop Ec/No N0 THD[dB] BSC6900 Inter-RAT R99 PS measure InterRATR99PsThd2FRS stop RSCP CP THD[dBm] BSC6900

InterRatReportMode

Inter-RAT report mode

BSC6900

InterRatReportMode

Inter-RAT report mode

BSC6900

Inter-RAT scaling factor InterRatTreselScalingFac for reselection tor delay BSC6900

InterRatUlMbdrTrigThres hold UL theshold

BSC6900

INTERVAL

Relative Time BSC6900

INTERVAL

Send PKT Interval[s]

BSC6900

IntraAblThdFor1FEcNo

1F event absolute EcNo threshold[dB] BSC6900 1F event absolute RSCP threshold[dBm] BSC6900

IntraAblThdFor1FRSCP

IntraFreqFilterCoef

Intra-freq meas L3 filter coeff BSC6900

Intra-frequency IntraFreqLdbPeriodTimer LDB period Len timer length BSC6900

IntraFreqMeasInd

Intra-freq Meas Ctrl Info Ind BSC6900 Intra-freq Measure Quantity Intra-

IntraFreqMeasQuantity

BSC6900

Frequency Neighboring IntraFreqNCellDetectSwit Cell Detect ch Switch

BSC6900

IntraMbscInd

Intra-MBSC Indication.

BSC6900

IntraRelThdFor1A

1A Event Relative Threshold[dB] BSC6900

CS non VP service 1A event relative IntraRelThdFor1ACSNVP THD[0.5dB]

BSC6900

IntraRelThdFor1ACSVP

VP service 1A event relative THD[0.5dB] BSC6900 PS service 1A event relative threshold[0.5d B] BSC6900 1B Event Relative Threshold[dB] BSC6900

IntraRelThdFor1APS

IntraRelThdFor1B

CS non VP service 1B event relative IntraRelThdFor1BCSNVP THD[0.5dB]

BSC6900

IntraRelThdFor1BCSVP

VP service 1B event relative THD[0.5dB] BSC6900 PS service 1B event relative threshold[0.5d B] BSC6900

IntraRelThdFor1BPS

IntrTmr

TinTR[ms]

BSC6900

INTV

Time Interval OMU Automatic Switchover Interval

BSC6900

INTV

BSC6900

IP

IP Address

BSC6900

IPADDR

Local IP address

BSC6900

IPADDR

IP address

BSC6900

IPADDR

IP address

BSC6900

IPADDR

IP address

BSC6900

IPADDR

Local IP address

BSC6900

IPADDR

Packet source IP address BSC6900

IPADDR

Next Hop IP address.

BSC6900

IPADDR

Local IP address

BSC6900

IPADDR

IP address

BSC6900

IPHC

Head compress

BSC6900

IPHC

Head compress

BSC6900

IPINDEX

IP address index

BSC6900

IPINDEX

IP address index

BSC6900

IPLOGPORTFLAG

Whether Binding logical port or not BSC6900

IPLPN

Logic port No. BSC6900

IPMUXINDEX

IP MUX Index BSC6900 NodeB IP_TRANS Slot No. NodeB IP_TRANS Subrack No.

IPSN

BSC6900

IPSRN

BSC6900

IPTRANSAPARTIND

IP Trans Apart Ind BSC6900 Access class 0 barred indicator BSC6900 Access class 10 barred indicator Access class 11 barred indicator Access class 12 barred indicator Access class 13 barred indicator

IsAccessClass0Barred

IsAccessClass10Barred

BSC6900

IsAccessClass11Barred

BSC6900

IsAccessClass12Barred

BSC6900

IsAccessClass13Barred

BSC6900

IsAccessClass14Barred

Access class 14 barred indicator Access class 15 barred indicator

BSC6900

IsAccessClass15Barred

BSC6900

IsAccessClass1Barred

Access class 1 barred indicator BSC6900 Access class 2 barred indicator BSC6900 Access class 3 barred indicator BSC6900 Access class 4 barred indicator BSC6900 Access class 5 barred indicator BSC6900 Access class 6 barred indicator BSC6900 Access class 7 barred indicator BSC6900 Access class 8 barred indicator BSC6900 Access class 9 barred indicator BSC6900 Is First Class Transport Resource Group

IsAccessClass2Barred

IsAccessClass3Barred

IsAccessClass4Barred

IsAccessClass5Barred

IsAccessClass6Barred

IsAccessClass7Barred

IsAccessClass8Barred

IsAccessClass9Barred

ISFIRSTCLASS

BSC6900

IsFixedMachsWinSize

Is MAC-hs window size fixed or not

BSC6900

ISPRIMARYPLMN

Primary Operator Flag BSC6900

ISQOSPATH

IS QOSPATH BSC6900

IsROOTNODE

Is Root Node

BSC6900

ISSUPPORTFRA

Support FRA

BSC6900

ITFT

Interface Type BSC6900 AC Restriction Interval of Cell By IU BSC6900 DL OLC released RAB number BSC6900 UL OLC released RAB number BSC6900 Iu CS Release protection timer[s] BSC6900

IuAcIntervalOfCell

IubDlOlcRelRabNum

IubUlOlcRelRabNum

IuCSRelNoRABTmr

IUCTHD

IU max call barring ratio

BSC6900

IUFCSW

IU flow control switch BSC6900

IuPSRelNoRABTmr

Iu PS Release protection timer[s] BSC6900 Congestion Control Indicator over IUR for NRNC BSC6900 Iur downlink transfer control threshold BSC6900 Iur downlink transfer control threshold BSC6900 Iur downlink transfer restore threshold BSC6900 Iur downlink transfer restore threshold BSC6900 Iur downlink transfer flow control switch BSC6900 IUR Interface Existing Indication

IurCongCtrlSuppInd

IURDLCTHD

IURDLCTHD

IURDLRTHD

IURDLRTHD

IURDLSW

IurExistInd

BSC6900

IURGCTHD

Iur-g control threshold

BSC6900

IURGCTHD

Iur-g control threshold

BSC6900

IURGRTHD

Iur-g restore threshold

BSC6900

IURGRTHD

Iur-g restore threshold

BSC6900

IURGSW

Iur-g flow control switch BSC6900 Hsdpa cap ind over IUR for NRNC BSC6900 Hsupa cap ind over IUR for NRNC BSC6900 Iur uplink transfer control threshold BSC6900 Iur uplink transfer control threshold BSC6900 Iur uplink transfer restore threshold BSC6900 Iur uplink transfer restore threshold BSC6900 Iur uplink transfer flow control switch BSC6900

IurHsdpaSuppInd

IurHsupaSuppInd

IURULCTHD

IURULCTHD

IURULRTHD

IURULRTHD

IURULSW

IuStatePolicyForPool

Iu State Policy For RncPool BSC6900

J0BYTE_FORMAT

J0 Byte Format BSC6900

J0RXBYTE_FORMAT

J0 Expected Incept Format BSC6900

J0RXT

J0 expected incept type

BSC6900

J0RXVALUE

J0 expected incept value

BSC6900

J0TXBYTE_FORMAT

J0 Transmit Format

BSC6900

J0TXT

J0 transmit type

BSC6900

J0TXVALUE

J0 transmit value

BSC6900

J0TYPE

J0 type

BSC6900

J1BYTE_FORMAT

J1 Byte Format BSC6900

J1RXBYTE_FORMAT

J1 Expected Incept Format BSC6900

J1RXT

J1 expected incept type

BSC6900

J1RXVALUE

J1 expected incept value

BSC6900

J1TXBYTE_FORMAT

J1 Transmit Format

BSC6900

J1TXT

J1 transmit type

BSC6900

J1TXVALUE

J1 transmit value

BSC6900

J1TYPE

J1 type

BSC6900

J2ALMSWITCH

J2 mismatch alarm switch

BSC6900

J2BYTE_FORMAT

J2 Byte Format BSC6900

J2MODE

J2 length

BSC6900

J2RXVALUE

J2 expected incept value

BSC6900

J2TXVALUE

J2 transmit value

BSC6900

JAUTOADD

Automatic Append J Byte BSC6900

K2MODE

K2 Mode

BSC6900

KEEPALIVE

Keep-alive timer length[S] BSC6900

KEEPTMR

Timer_KeepAlive the Period of KPI Alarm Check RNC Report KPI Alarm Switch

BSC6900

KpiAlarmChkTimes

BSC6900

KpiAlarmSwitch

BSC6900

LAC

Location area code BSC6900

L