Upload
nur-cholis-hadi
View
224
Download
0
Embed Size (px)
Citation preview
7/26/2019 Brosur Flexible Cable
http://slidepdf.com/reader/full/brosur-flexible-cable 1/5PT KMI Wire and Cable Tbk
FLEXIBLE
CABLES
Wire and Cable
A QUALITY CABLE MANUFACTURER
SINCE 1972
7/26/2019 Brosur Flexible Cable
http://slidepdf.com/reader/full/brosur-flexible-cable 2/5
Cable Size(No. of core
x Conductor Area)
ConductorMake-up
(No.of wirex Diameter)
CurrentCarrying
Capacity inair 30˚C
ShortCircuit
Current1 Sec.
Insulation/
SheathThickness OverallDiameter CableWeight
StandardPacking
Length*20˚CConductor 70˚CInsulation
DC Resistance at
nom.
(mm 2 )
nom.
(mm)
max.
(A)
max.
(A)
nom.
(mm)
(meter/
packing)
max.
(ohm/km)
min.
(Mohm.km)
approx.
(mm)
approx.
(kg/km)
Applications:• Power cord or internal wiring with low mechanical stress for electrical equipments,
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
100/c3 x 4 56 x 0.30 4.95 0.007 26 460 0.8 / 1.0 11.1 232
Standard Specification: IEC 60227-6 : 2001 (IEC 71c)
Flexible Copper Conductor, PVC Insulated, PVC Sheathed
CU/PVC/PVC 450/750 V
machineries, luminaires and other portable appliances use in dry indoor premises
and outdoor application.
• Permanent exposed wiring in humid environment, installation in tray or
under plaster for industrial three phase 380 - 415 VAC or single phase 220 -
240 VAC multipurpose application, inherently flame retardant in compliance
with IEC 60332-1.
Test Voltage : 2,5 00 VAC/5 minutes
* c = coil
NYMHY H07 VVF ( White Colored Sheath)
7/26/2019 Brosur Flexible Cable
http://slidepdf.com/reader/full/brosur-flexible-cable 3/5
* c = coil d = drum
Applications:
• Power cord or internal wiring with medium mechanical stress for electricalequipments, machineries, luminaires and other portable appliances in dryindoor premises and outdoor application.
• Permanent exposed wiring in humid environment, installation in tray orunder plaster for industrial three phase 380 - 415 VAC or single phase 220 -240 VAC multipurpose application, inherently flame retardant in compliancewith IEC 60332-1.
Cable Size(No. of core
x Conductor Area)
ConductorMake-up
(No.of wirex Diameter)
CurrentCarrying
Capacity inair 30˚C
ShortCircuit
Current1 Sec.
Insulation/
SheathThickness OverallDiameter CableWeight
StandardPacking
Length*20˚CConductor 70˚CInsulation
DC Resistance at
nom.
(mm 2 )
0.007
0.006
0.0056
0.0046
0.0044
0.007
0.006
0.0056
0.0046
0.0044
0.007
0.006
0.0056
0.0046
0.0044
0.007
0.006
0.0056
0.0046
0.0044
26
33
45
61
80
26
33
45
61
80
26
33
45
61
80
20
25
34
46
61
460
690
1,150
1,840
2,875
460
690
1,150
1,840
2,875
460
690
1,150
1,840
2,875
460
690
1,150
1,840
2,875
0.8 / 1.0
0.8 / 1.0
1.0 / 1.3
1.0 / 1.3
1.2 / 1.6
0.8 / 1.0
0.8 / 1.3
1.0 / 1.3
1.0 / 1.3
1.2 / 1.6
0.8 / 1.3
0.8 / 1.3
1.0 / 1.3
1.0 / 1.6
1.2 / 2.0
0.8 / 1.3
0.8 / 1.3
1.0 / 1.6
1.0 / 1.6
1.2 / 2.0
10.5
12.0
15.5
17.6
21.8
11.1
13.4
16.4
18.8
23.2
12.9
14.7
18.1
21.4
26.4
14.1
16.1
20.5
23.5
29.0
189
256
428
596
914
232
337
530
751
1,153
305
414
664
979
1,509
373
509
843
1,198
1,845
100/c
100/c
1,000/d
1,000/d
1,000/d
100/c
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
nom.
(mm)
max.
(A)
max.
(A)
nom.
(mm)
(meter/
packing)
max.
(ohm/km)
min.
(Mohm.km)
approx.
(mm)
approx.
(kg/km)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
4
3
1
1
0
4
3
1
1
0
4
3
1
1
0
4
3
1
1
0
95
30
91
21
78
95
30
91
21
78
95
30
91
21
78
95
30
91
21
78
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
2
2
2
2
2
3
3
3
3
3
4
4
4
4
4
5
5
5
5
5
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
56
84
80
126
196
56
84
80
126
196
56
84
80
126
196
56
84
80
126
196
0.30
0.30
0.40
0.40
0.40
0.30
0.30
0.40
0.40
0.40
0.30
0.30
0.40
0.40
0.40
0.30
0.30
0.40
0.40
0.40
Test Voltage : 2,500 VAC/5 minutes
Standard Specification: IEC 60227-6 : 2001 (IEC 71c)
Flexible Copper Conductor, PVC Insulated, PVC Sheathed
NYYHY H07VVF (Black Colored Sheath)
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
4
6
10
16
25
4
6
10
16
25
4
6
10
16
25
4
6
10
16
25
CU/PVC/PVC 450/750 V
7/26/2019 Brosur Flexible Cable
http://slidepdf.com/reader/full/brosur-flexible-cable 4/5
Applications:
• Power cord or internal wiring with medium mechanical stress for electrical equipments,machineries, luminaires and other portable appliances in dry indoor premises and outdoorapplication.
• Permanent exposed wiring in humid environment, installation in tray or under plaster forindustrial three phase 380 - 415 VAC or single phase 220 - 240 VAC multipurposeapplication, inherently flame retardant in compliance with IEC 60332-1.
Cable Size(No. of core
x Conductor
Area)
ConductorMake-up
(No.of wire
x Diameter)
CurrentCarrying
Capacity inair 30˚C
ShortCircuitCurrent1 Sec.
Insulation/ Sheath
ThicknessOverall
DiameterCable
Weight
StandardPackingLength
*20˚C
Conductor70˚C
Insulation
DC Resistance at
nom.
(mm 2 )
0.004
0.004
0.004
0.004
0.003
0.003
0.003
0.003
0.003
0.003
0.004
0.004
0.004
0.004
0.003
0.003
0.003
0.003
0.003
0.004
0.004
0.004
0.004
0.003
0.003
0.003
0.003
0.003
0.004
0.004
0.004
0.004
0.003
0.003
0.003
0.003
0.0030.004
0.004
115
146
184
221
259
301
343
412
475
564
119
150
187
223
260
298
336
398
454
107
135
170
202
237
273
309
366
418
99
124
156
186
218
251
285
338
38793
117
4,025
5,750
8,050
10,925
13,801
17,251
21,276
27,601
34,501
46,002
4,025
5,750
8,050
10,925
13,801
17,251
21,276
27,601
34,501
4,025
5,750
8,050
10,925
13,801
17,251
21,276
27,601
34,501
4,025
5,750
8,050
10,925
13,801
17,251
21,276
27,601
34,5014,025
5,750
1.2 / 1.4
1.4 / 1.4
1.4 / 1.4
1.6 / 1.5
1.6 / 1.5
1.8 / 1.6
2.0 / 1.7
2.2 / 1.8
2.4 / 1.9
2.6 / 2.0
1.2 / 1.8
1.4 / 1.8
1.4 / 1.9
1.6 / 2.0
1.6 / 2.1
1.8 / 2.2
2.0 / 2.4
2.2 / 2.6
2.4 / 2.7
1.2 / 1.8
1.4 / 1.8
1.4 / 1.9
1.6 / 2.1
1.6 / 2.2
1.8 / 2.3
2.0 / 2.5
2.2 / 2.7
2.4 / 2.9
1.2 / 1.8
1.4 / 1.9
1.4 / 2.1
1.6 / 2.2
1.6 / 2.3
1.8 / 2.5
2.0 / 2.7
2.2 / 2.9
2.4 / 3.11.2 / 1.9
1.4 / 2.0
13.2
15.1
17.0
19.2
20.9
23.2
25.6
28.9
31.9
36.1
25.9
30.2
34.1
38.7
42.4
46.8
51.6
58.5
64.5
27.5
32.2
36.5
41.5
45.4
50.1
55.5
62.6
69.3
30.3
35.8
40.6
45.9
50.3
56.0
61.7
69.6
77.333.5
39.6
440
615
831
1,083
1,345
1,663
2,030
2,643
3,283
4,294
1,229
1,626
2,160
2,813
3,456
4,222
5,127
6,669
8,688
1,565
2,105
2,854
3,707
4,589
5,630
6,895
8,940
11,798
1,980
2,724
3,692
4,784
5,929
7,361
8,960
11,637
15,4432,442
3,393
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d1,000/d
1,000/d
nom.
(mm)
max.
(A)
max.
(A)
nom.
(mm)
(meter/
packing)
max.
(ohm/km)
min.
(Mohm.km)
approx.
(mm)
approx.
(kg/km)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
00
0
554
386
272
206
161
129
106
0801
0641
0486
554
386
272
206
161
129
106
0801
0641
554
386
272
206
161
129
106
0801
0641
554
386
272
206
161
129
106
0801
0641544
386
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
xx
x
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
3
4
4
4
4
4
4
4
4
45
5
35
50
70
95
120
150
185
240
300
400
35
50
70
95
120
150
185
240
300
35
50
70
95
120
150
185
240
300
35
50
70
95
120
150
185
240
30035
50
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
xx
x
276
396
360
475
608
756
925
1221
1530
2035
276
396
360
475
608
756
925
1221
1530
276
396
360
475
608
756
925
1221
1530
276
396
360
475
608
756
925
1221
1530276
396
0.40
0.40
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.40
0.40
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.40
0.40
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.40
0.40
0.50
0.50
0.50
0.50
0.50
0.50
0.500.40
0.40
Test Voltage : 3,500 VAC/5 minutes
* d = drum
Standard Specification: SNI IEC 60502-1 : 2009
Flexible Copper Conductor, PVC Insulated, PVC Sheathed
NYY Flexible (Black Colored Sheath)
CU/PVC/PVC 0.6/1 kV
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
7/26/2019 Brosur Flexible Cable
http://slidepdf.com/reader/full/brosur-flexible-cable 5/5
PT KMI Wire and Cable Tbk Jl. Raya Bekasi Km. 23,1 - Cakung, Jakarta 13910, INDONESIA
PO BOX 2468, Jakarta 10001, Phone +62-21-4601733, Fax +62-21-4601738
E-mail: [email protected], [email protected]
Website: www.kmi.co.id
* c = coil d = drum
Applications:• Power cord or internal wiring with low mechanical stress for electrical
equipments, machineries, distribution panels, luminaires and other electricalused in dry indoor premises, substitutes NYA.
• Permanent instalation in conduit, inherently flame retardant in compliancewith IEC 60332-1.
Flexible Copper Conductor, PVC Insulated
Cable Size(No. of core
x Conductor
Area)
ConductorMake-up
(No.of wire
x Diameter)
CurrentCarrying
Capacity inair 30˚C
ShortCircuitCurrent1 Sec.
Insulation/ Thickness
OverallDiameter
CableWeight
StandardPackingLength
*20˚C
Conductor70˚C
Insulation
DC Resistance at
nom.
(mm 2 )
0.013
0.011
0.010
6
10
16
58
86
115
0.6
0.6
0.6
2.2
2.3
2.6
9
12
16
100/c
100/c
100/c
nom.
(mm)
max.
(A)
max.
(A)
nom.
(mm)
(meter/
packing)
max.
(ohm/km)
min.
(Mohm.km)
approx.
(mm)
approx.
(kg/km)
.
.
.
39
26
19
0
0
5
0.5
0.75
1.00
x
x
x
16
24
32
0.20
0.20
0.20
Test Voltage : 2,000 VAC/5 minutes
Rated Voltage : 300/500 V
Standard Specification : SNI 04-6629.3 : 2006 (IEC 06)
Test Voltage : 2,500 VAC/5 minutes
Cable Size(No. of core
x Conductor Area)
ConductorMake-up
(No.of wire x Diameter)
CurrentCarrying
Capacity inair 30˚C
ShortCircuit
Current1 Sec.
Insulation/ Thickness
OverallDiameter
CableWeight
StandardPacking
Length*
20˚CConductor
70˚CInsulation
DC Resistance at
nom.
(mm 2 )
0.010
0.009
0.007
0.006
0.0056
0.0046
0.0044
0.00380.0037
0.0032
0.0032
0.0029
0.0029
0.0029
0.0028
24
32
41
53
72
97
128
156195
243
287
342
386
441
520
173
288
460
690
1,150
1,840
2,875
4,0255,750
8,050
10,925
13,801
17,251
21,276
27,601
0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.21.4
1.4
1.6
1.6
1.8
2.0
2.2
3.2
3.9
4.4
5.0
6.4
7.4
9.3
10.512.4
14.2
16.5
18.5
20.3
22.6
25.7
22
35
52
73
122
180
275
347531
735
969
1,279
1,559
1,899
2,479
100/c
100/c
100/c
100/c
100/c
100/c
1,000/d
1,000/d1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
500/d
500/d
nom.
(mm)
max.
(A)
max.
(A)
nom.
(mm)
(meter/
packing)
max.
(ohm/km)
min.
(Mohm.km)
approx.
(mm)
approx.
(kg/km)
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
13
7
4
3
1
1
0
00
0
0
0
0
0
0
3
98
95
30
91
21
78
554386
272
206
161
129
106
0801
1.5
2.5
4
6
10
16
25
3550
70
95
120
150
185
240
x
x
x
x
x
x
x
xx
x
x
x
x
x
x
30
50
56
84
80
126
196
276396
360
475
608
756
925
1221
0.25
0.25
0.30
0.30
0.40
0.40
0.40
0.400.40
0.50
0.50
0.50
0.50
0.50
0.50
Rated Voltage : 450/750 V
Standard Specification : SNI 04-6629.3 : 2006 (IEC 02)
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
NYAF
CU/PVC
R e v . 4 . 0 / 2 2 - 0 9 - 2 0 1 5
r h e m a