5
7/26/2019 Brosur Flexible Cable http://slidepdf.com/reader/full/brosur-flexible-cable 1/5 PT KMI Wire and Cable Tbk FLEXIBLE CABLES Wire and Cable  A QUALITY CABLE MANUFACTURER  SINCE 1972

Brosur Flexible Cable

Embed Size (px)

Citation preview

Page 1: Brosur Flexible Cable

7/26/2019 Brosur Flexible Cable

http://slidepdf.com/reader/full/brosur-flexible-cable 1/5PT KMI Wire and Cable Tbk 

FLEXIBLE 

CABLES 

Wire and Cable

 A QUALITY CABLE MANUFACTURER

 SINCE 1972

Page 2: Brosur Flexible Cable

7/26/2019 Brosur Flexible Cable

http://slidepdf.com/reader/full/brosur-flexible-cable 2/5

Cable Size(No. of core

x Conductor Area)

ConductorMake-up

(No.of wirex Diameter)

CurrentCarrying

Capacity inair 30˚C

ShortCircuit

Current1 Sec.

Insulation/ 

SheathThickness OverallDiameter CableWeight

StandardPacking

Length*20˚CConductor 70˚CInsulation

DC Resistance at

nom.

(mm 2  ) 

nom.

(mm) 

max.

(A) 

max.

(A) 

nom.

(mm) 

(meter/

packing) 

max.

(ohm/km) 

min.

(Mohm.km) 

approx.

(mm) 

approx.

(kg/km) 

Applications:• Power cord or internal wiring with low mechanical stress for electrical equipments,

PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

100/c3 x 4 56 x 0.30   4.95   0.007   26 460   0.8 / 1.0 11.1 232

Standard Specification: IEC 60227-6 : 2001 (IEC 71c)

Flexible Copper Conductor, PVC Insulated, PVC Sheathed 

CU/PVC/PVC 450/750 V

machineries, luminaires and other portable appliances use in dry indoor premises

and outdoor application.

• Permanent exposed wiring in humid environment, installation in tray or 

under plaster for industrial three phase 380 - 415 VAC or single phase 220 -

240 VAC multipurpose application, inherently flame retardant in compliance

with IEC 60332-1.

Test Voltage : 2,5 00 VAC/5 minutes

* c = coil

NYMHY H07 VVF ( White Colored Sheath)

Page 3: Brosur Flexible Cable

7/26/2019 Brosur Flexible Cable

http://slidepdf.com/reader/full/brosur-flexible-cable 3/5

* c = coil d = drum

Applications:

• Power cord or internal wiring with medium mechanical stress for electricalequipments, machineries, luminaires and other portable appliances in dryindoor premises and outdoor application.

• Permanent exposed wiring in humid environment, installation in tray orunder plaster for industrial three phase 380 - 415 VAC or single phase 220 -240 VAC multipurpose application, inherently flame retardant in compliancewith IEC 60332-1.

Cable Size(No. of core

x Conductor Area)

ConductorMake-up

(No.of wirex Diameter)

CurrentCarrying

Capacity inair 30˚C

ShortCircuit

Current1 Sec.

Insulation/ 

SheathThickness OverallDiameter CableWeight

StandardPacking

Length*20˚CConductor 70˚CInsulation

DC Resistance at

nom.

(mm 2  ) 

0.007

0.006

0.0056

0.0046

0.0044

0.007

0.006

0.0056

0.0046

0.0044

0.007

0.006

0.0056

0.0046

0.0044

0.007

0.006

0.0056

0.0046

0.0044

26

33

45

61

80

26

33

45

61

80

26

33

45

61

80

20

25

34

46

61

460

690

1,150

1,840

2,875

460

690

1,150

1,840

2,875

460

690

1,150

1,840

2,875

460

690

1,150

1,840

2,875

0.8 / 1.0

0.8 / 1.0

1.0 / 1.3

1.0 / 1.3

1.2 / 1.6

0.8 / 1.0

0.8 / 1.3

1.0 / 1.3

1.0 / 1.3

1.2 / 1.6

0.8 / 1.3

0.8 / 1.3

1.0 / 1.3

1.0 / 1.6

1.2 / 2.0

0.8 / 1.3

0.8 / 1.3

1.0 / 1.6

1.0 / 1.6

1.2 / 2.0

10.5

12.0

15.5

17.6

21.8

11.1

13.4

16.4

18.8

23.2

12.9

14.7

18.1

21.4

26.4

14.1

16.1

20.5

23.5

29.0

189

256

428

596

914

232

337

530

751

1,153

305

414

664

979

1,509

373

509

843

1,198

1,845

100/c

100/c

1,000/d

1,000/d

1,000/d

100/c

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

nom.

(mm) 

max.

(A) 

max.

(A) 

nom.

(mm) 

(meter/

packing) 

max.

(ohm/km) 

min.

(Mohm.km) 

approx.

(mm) 

approx.

(kg/km) 

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

4

3

1

1

0

4

3

1

1

0

4

3

1

1

0

4

3

1

1

0

95

30

91

21

78

95

30

91

21

78

95

30

91

21

78

95

30

91

21

78

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

2

2

2

2

2

3

3

3

3

3

4

4

4

4

4

5

5

5

5

5

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

56

84

80

126

196

56

84

80

126

196

56

84

80

126

196

56

84

80

126

196

0.30

0.30

0.40

0.40

0.40

0.30

0.30

0.40

0.40

0.40

0.30

0.30

0.40

0.40

0.40

0.30

0.30

0.40

0.40

0.40

Test Voltage : 2,500 VAC/5 minutes

Standard Specification: IEC 60227-6 : 2001 (IEC 71c)

Flexible Copper Conductor, PVC Insulated, PVC Sheathed 

NYYHY H07VVF (Black Colored Sheath)

PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

4

6

10

16

25

4

6

10

16

25

4

6

10

16

25

4

6

10

16

25

CU/PVC/PVC 450/750 V

Page 4: Brosur Flexible Cable

7/26/2019 Brosur Flexible Cable

http://slidepdf.com/reader/full/brosur-flexible-cable 4/5

Applications:

• Power cord or internal wiring with medium mechanical stress for electrical equipments,machineries, luminaires and other portable appliances in dry indoor premises and outdoorapplication.

• Permanent exposed wiring in humid environment, installation in tray or under plaster forindustrial three phase 380 - 415 VAC or single phase 220 - 240 VAC multipurposeapplication, inherently flame retardant in compliance with IEC 60332-1.

Cable Size(No. of core

x Conductor

 Area) 

ConductorMake-up

(No.of wire 

x Diameter) 

CurrentCarrying

Capacity inair 30˚C

ShortCircuitCurrent1 Sec.

Insulation/ Sheath

ThicknessOverall

DiameterCable

Weight

StandardPackingLength

*20˚C

Conductor70˚C

Insulation

DC Resistance at

nom.

(mm 2  ) 

0.004

0.004

0.004

0.004

0.003

0.003

0.003

0.003

0.003

0.003

0.004

0.004

0.004

0.004

0.003

0.003

0.003

0.003

0.003

0.004

0.004

0.004

0.004

0.003

0.003

0.003

0.003

0.003

0.004

0.004

0.004

0.004

0.003

0.003

0.003

0.003

0.0030.004

0.004

115

146

184

221

259

301

343

412

475

564

119

150

187

223

260

298

336

398

454

107

135

170

202

237

273

309

366

418

99

124

156

186

218

251

285

338

38793

117

4,025

5,750

8,050

10,925

13,801

17,251

21,276

27,601

34,501

46,002

4,025

5,750

8,050

10,925

13,801

17,251

21,276

27,601

34,501

4,025

5,750

8,050

10,925

13,801

17,251

21,276

27,601

34,501

4,025

5,750

8,050

10,925

13,801

17,251

21,276

27,601

34,5014,025

5,750

1.2 / 1.4

1.4 / 1.4

1.4 / 1.4

1.6 / 1.5

1.6 / 1.5

1.8 / 1.6

2.0 / 1.7

2.2 / 1.8

2.4 / 1.9

2.6 / 2.0

1.2 / 1.8

1.4 / 1.8

1.4 / 1.9

1.6 / 2.0

1.6 / 2.1

1.8 / 2.2

2.0 / 2.4

2.2 / 2.6

2.4 / 2.7

1.2 / 1.8

1.4 / 1.8

1.4 / 1.9

1.6 / 2.1

1.6 / 2.2

1.8 / 2.3

2.0 / 2.5

2.2 / 2.7

2.4 / 2.9

1.2 / 1.8

1.4 / 1.9

1.4 / 2.1

1.6 / 2.2

1.6 / 2.3

1.8 / 2.5

2.0 / 2.7

2.2 / 2.9

2.4 / 3.11.2 / 1.9

1.4 / 2.0

13.2

15.1

17.0

19.2

20.9

23.2

25.6

28.9

31.9

36.1

25.9

30.2

34.1

38.7

42.4

46.8

51.6

58.5

64.5

27.5

32.2

36.5

41.5

45.4

50.1

55.5

62.6

69.3

30.3

35.8

40.6

45.9

50.3

56.0

61.7

69.6

77.333.5

39.6

440

615

831

1,083

1,345

1,663

2,030

2,643

3,283

4,294

1,229

1,626

2,160

2,813

3,456

4,222

5,127

6,669

8,688

1,565

2,105

2,854

3,707

4,589

5,630

6,895

8,940

11,798

1,980

2,724

3,692

4,784

5,929

7,361

8,960

11,637

15,4432,442

3,393

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

1,000/d1,000/d

1,000/d

nom.

(mm) 

max.

(A) 

max.

(A) 

nom.

(mm) 

(meter/

packing) 

max.

(ohm/km) 

min.

(Mohm.km) 

approx.

(mm) 

approx.

(kg/km) 

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

0

00

0

554

386

272

206

161

129

106

0801

0641

0486

554

386

272

206

161

129

106

0801

0641

554

386

272

206

161

129

106

0801

0641

554

386

272

206

161

129

106

0801

0641544

386

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

xx

x

1

1

1

1

1

1

1

1

1

1

2

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

3

4

4

4

4

4

4

4

4

45

5

35

50

70

95

120

150

185

240

300

400

35

50

70

95

120

150

185

240

300

35

50

70

95

120

150

185

240

300

35

50

70

95

120

150

185

240

30035

50

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

xx

x

276

396

360

475

608

756

925

1221

1530

2035

276

396

360

475

608

756

925

1221

1530

276

396

360

475

608

756

925

1221

1530

276

396

360

475

608

756

925

1221

1530276

396

0.40

0.40

0.50

0.50

0.50

0.50

0.50

0.50

0.50

0.50

0.40

0.40

0.50

0.50

0.50

0.50

0.50

0.50

0.50

0.40

0.40

0.50

0.50

0.50

0.50

0.50

0.50

0.50

0.40

0.40

0.50

0.50

0.50

0.50

0.50

0.50

0.500.40

0.40

Test Voltage : 3,500 VAC/5 minutes

* d = drum

Standard Specification: SNI IEC 60502-1 : 2009

Flexible Copper Conductor, PVC Insulated, PVC Sheathed

NYY Flexible (Black Colored Sheath)

CU/PVC/PVC 0.6/1 kV

PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

Page 5: Brosur Flexible Cable

7/26/2019 Brosur Flexible Cable

http://slidepdf.com/reader/full/brosur-flexible-cable 5/5

PT KMI Wire and Cable Tbk Jl. Raya Bekasi Km. 23,1 - Cakung, Jakarta 13910, INDONESIA 

PO BOX 2468, Jakarta 10001, Phone +62-21-4601733, Fax +62-21-4601738

E-mail: [email protected], [email protected]

Website: www.kmi.co.id

* c = coil d = drum

Applications:• Power cord or internal wiring with low mechanical stress for electrical

equipments, machineries, distribution panels, luminaires and other electricalused in dry indoor premises, substitutes NYA.

• Permanent instalation in conduit, inherently flame retardant in compliancewith IEC 60332-1.

Flexible Copper Conductor, PVC Insulated

Cable Size(No. of core

x Conductor

 Area) 

ConductorMake-up

(No.of wire 

x Diameter) 

CurrentCarrying

Capacity inair 30˚C

ShortCircuitCurrent1 Sec.

Insulation/ Thickness

OverallDiameter

CableWeight

StandardPackingLength

*20˚C

Conductor70˚C

Insulation

DC Resistance at

nom.

(mm 2  ) 

0.013

0.011

0.010

6

10

16

58

86

115

0.6

0.6

0.6

2.2

2.3

2.6

9

12

16

100/c

100/c

100/c

nom.

(mm) 

max.

(A) 

max.

(A) 

nom.

(mm) 

(meter/

packing) 

max.

(ohm/km) 

min.

(Mohm.km) 

approx.

(mm) 

approx.

(kg/km) 

.

.

.

39

26

19

0

0

5

0.5

0.75

1.00

x

x

x

16

24

32

0.20

0.20

0.20

Test Voltage : 2,000 VAC/5 minutes

 Rated Voltage : 300/500 V 

Standard Specification : SNI 04-6629.3 : 2006 (IEC 06)

Test Voltage : 2,500 VAC/5 minutes

Cable Size(No. of core

x Conductor Area) 

ConductorMake-up

(No.of wire x Diameter) 

CurrentCarrying

Capacity inair 30˚C

ShortCircuit

Current1 Sec.

Insulation/ Thickness

OverallDiameter

CableWeight

StandardPacking

Length*

20˚CConductor

70˚CInsulation

DC Resistance at

nom.

(mm 2  ) 

0.010

0.009

0.007

0.006

0.0056

0.0046

0.0044

0.00380.0037

0.0032

0.0032

0.0029

0.0029

0.0029

0.0028

24

32

41

53

72

97

128

156195

243

287

342

386

441

520

173

288

460

690

1,150

1,840

2,875

4,0255,750

8,050

10,925

13,801

17,251

21,276

27,601

0.7

0.8

0.8

0.8

1.0

1.0

1.2

1.21.4

1.4

1.6

1.6

1.8

2.0

2.2

3.2

3.9

4.4

5.0

6.4

7.4

9.3

10.512.4

14.2

16.5

18.5

20.3

22.6

25.7

22

35

52

73

122

180

275

347531

735

969

1,279

1,559

1,899

2,479

100/c

100/c

100/c

100/c

100/c

100/c

1,000/d

1,000/d1,000/d

1,000/d

1,000/d

1,000/d

1,000/d

500/d

500/d

nom.

(mm) 

max.

(A) 

max.

(A) 

nom.

(mm) 

(meter/

packing) 

max.

(ohm/km) 

min.

(Mohm.km) 

approx.

(mm) 

approx.

(kg/km) 

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

13

7

4

3

1

1

0

00

0

0

0

0

0

0

3

98

95

30

91

21

78

554386

272

206

161

129

106

0801

1.5

2.5

4

6

10

16

25

3550

70

95

120

150

185

240

x

x

x

x

x

x

x

xx

x

x

x

x

x

x

30

50

56

84

80

126

196

276396

360

475

608

756

925

1221

0.25

0.25

0.30

0.30

0.40

0.40

0.40

0.400.40

0.50

0.50

0.50

0.50

0.50

0.50

 Rated Voltage : 450/750 V 

Standard Specification : SNI 04-6629.3 : 2006 (IEC 02)

PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification