20
Brooten Area Water Use June 19, 2008

Brooten Area Water Use June 19, 2008. Brooten – Initial Conflict Study Area

Embed Size (px)

Citation preview

Brooten Area Water Use

June 19, 2008

Brooten – Initial Conflict Study Area

A

A’

Brooten – Geologic Cross-Section

Brooten – Extent of LowerBuried Aquifer

Brooten – General Extent ofBuried Aquifers

Annual Water Use Under Permits For Buried Artesian Aquifers Water Use Conflict Area Near Brooten

0

100

200

300

400

500

600

700

800

900

1000

An

nu

al A

pp

rop

riat

ion

(M

illi

on

Gal

lon

s p

er Y

ear)

Brooten Area Water Levels

0

10

20

30

40

50

60

70

80

90

100Jan-07 Feb-07 Mar-07 Apr-07 May-07 Jun-07 Jul-07 Aug-07 Sep-07 Oct-07 Nov-07 Dec-07 Jan-08 Feb-08 Mar-08 Apr-08 May-08 Jun-08 Jul-08

De

pth

to

Wa

ter

(fe

et

BL

S)

73042(QWTA)

73041(QBAA)

61032(QWTA)

Lemcke(QBAA)

61037(QBAA)

73051(QWTA)

Rach(QBAA)

61039(QBAA)

61040(QWTA)

Domestic Well Water Levels

0

10

20

30

40

50

60

70

807/21/07

8/4/07

8/18/07

9/1/07

9/15/07

9/29/07

10/13/07

10/27/07

11/10/07

11/24/07

12/8/07

12/22/07

1/5/08

1/19/08

2/2/08

2/16/08

3/1/08

3/15/08

3/29/08

4/12/08

4/26/08

5/10/08

5/24/08

6/7/08

6/21/08

7/5/08

7/19/08

Dept

h to

Wat

er

(ft b

ls) Lemcke

Rach

Depth to water DNR obwell 61037

17

18

19

20

21

22

23

5/17/08 5/22/08 5/27/08 6/1/08 6/6/08 6/11/08 6/16/08 6/21/08

Dept

h be

low

top

of s

teel

cas

ing

Water Use Priorities

1. 2.

3.

4. 5.

6.

Non-essential uses

Domestic

water supply

Consumptive less than 10,000 gallons/day

Agricultural irrigation & processing of agric. products

Power production

Consumptive uses in excess of 10,000 gallons/day

Well Interference

Well interference is when a high capacity well impacts a domestic or public water supply well by reducing water levels beyond the reach of those wells.

Procedures defined in Minnesota Rules 6115.0730

Water Use ConflictWater use conflict occurs where the available supply of

waters of the state in a given area is limited to the extent that there are competing demands among existing and proposed users which exceed the reasonably available waters.

Procedures defined in Minnesota Rules 6115.0740

ThresholdsTwo types have been applied at high volume water user sites:

Aquifer protectionResource protection

Thresholds are not developed to prevent well interference.

The two-tiered threshold allows appropriation from the aquifer but also provides a buffer to protect the structural integrity of the aquifer itself.

Under this method, two threshold elevations are set, the first, at 50% of the pre-pumping available head is meant to act as a warning light to the appropriator(s). In general, this 50% level should not be breached until the well has been pumped for some time.

If the 50% level is achieved, the appropriator should be increasing the frequency of water level monitoring, actively investigating alternate water supplies, implementing more aggressive water conservation measures and planning to cut back their appropriation rates

Two tiered threshold

Land surface

0

20

40

60

80

100

120

140

160

180

200

Dept

h be

low la

ndsu

rface

(fee

t)

sand 180-199

swl=68 feet

50%=124 feet

1) Determine the SWL (static water level) below the land surface. SWL=68 feet

2) Determine the depth to top of the aquifer below the land surface.Top of aquifer=180 feet

3) Calculate available head above the top of the aquifer; top of aquifer minus SWL.Available head=180-68=112 feet

4) Calculate 50% of available head. Available head divided by 2.Available head/2=112/2=56 feet

5) Calculate threshold by subtracting 50% of available head from the depth to the top of the aquifer.Threshold=180-56=124 feet

The second threshold elevation is set at an elevation equivalent to 25% of the pre-pumping available head. If the 25% threshold is reached, appropriation from the aquifer should cease altogether or pumping minimized to such a degree that water levels stop declining or start recovering.

Land surface

0

20

40

60

80

100

120

140

160

180

200

Dept

h be

low la

ndsu

rface

(fee

t)

sand 180-199

swl=68 feet

25%=156 feet

1) Determine the SWL (static water level) below the land surface. SWL=68 feet

2) Determine the depth to top of the aquifer below the land surface.Top of aquifer=180 feet

3) Calculate available head above the top of the aquifer; top of aquifer minus SWL.Available head=180-68=112 feet

4) Calculate 50% of available head. Available head divided by 2.Available head/4=112/4=28 feet

5) Calculate threshold by subtracting 50% of available head from the depth to the top of the aquifer.Threshold=180-28=156 feet