4
Daniel ® Model 3804 Liquid Ultrasonic Flow Meter Key benefits of the Daniel Model 3804 Liquid Ultrasonic Meter Reduce unaccounted fluid loss Increase energy savings Intrinsically safe - explosion proof Lower capital costs Reduce maintenance costs Reduce inventory costs Reduce start-up time Improve uptime Reduce field technician costs Optimize meter operation

BRO_Liquid Ultrasonic 3804_EN

Embed Size (px)

DESCRIPTION

Key benefits of the Daniel Model 3804 Liquid Ultrasonic Meter Reduce unaccounted fluid loss Increase energy savings Intrinsically safe - explosion proof Lower capital costs Reduce maintenance costs Reduce inventory costs Reduce start-up time Improve uptime Reduce field technician costs Optimize meter operation

Citation preview

Daniel® Model 3804Liquid Ultrasonic Flow Meter

Key benefits of the Daniel Model 3804 Liquid Ultrasonic Meter

Reduce unaccounted fluid loss Increase energy savings Intrinsically safe - explosion proof Lower capital costs Reduce maintenance costs Reduce inventory costs Reduce start-up time Improve uptime Reduce field technician costs Optimize meter operation

Reduce unaccounted fluid loss with +/- 0.15% linearity using a transit time, four path chordal design Increase energy savings with low pressure drop design resulting in reduced pumping costs Explosion proof electronics, and intrinsically safe transducers Reduce meter runs and lower capital costs with > 20:1 rangeability Reduce maintenance costs with the ability to replace transducers in approximately 2 minutes Reduce inventory costs through the use of common components between sizes

Process product temperature: • -58° F to +260° F (-50° C to +127° C)

Operating viscosity range: • 150 centipoise maximum

Specific gravity range: • 0.35 to 1.50

Terminals: • Loading and off-loading such as ships, barges, and railcars) • Tank farms • Cavern storage

Offshore: • Floating production storage and off loading (FPSO) • Offshore platforms • Barges

Pipelines • Crude oil pipelines • Refined product pipelines • Ethane • LPG • Gasoline • Diesel • Aviation fuel

Applications

Hardware Features and Benefits

Process Parameters

Reduce start-up time configuring your meter with Daniel CUI (Customer Ultrasonic Interface)™

Improve uptime with real-time data and comprehensive meter health diagnostics Reduce field technician costs with remote communications and automated one page inspection reports Optimize meter operation with field upgradeable firmware and “Playback and Capture” function

Confidently make the right choice by partnering with Daniel Measurement and Control - the global leader in oil and gas custody transfer solutions.

Meter Capabilities

Line sizes: • 4 to 24 inch nominal bore (DN 100 to 600)

Operating pressure range: • 0 to 2250 psig (0 to 155 Bar)

Flanges: • Raised face and Ring Type Joint (RTJ) for

ANSI classes 150, 300, 600, 900 (PN 20, 50, 100, 150)

Software Features and Benefits

©2006 Daniel Measurement and Control, Inc., All Rights Reserved. Printed in the USA. DAN-Promo-USM3804-0606

Meter Performance

Linearity:• +/- 0.15% of measured value over a 40 to 4 fps (12.2 to 1.2 m/s) range• +/- 0.20% of measured value over a 40 to 2 fps (12.2 to 0.6 m/s) range

Repeatability:• ± 0.02% of measured value

Velocity Range:• Nominal 40 to 2 fps (12.2 to 0.6 m/s)

with over-range of up to 48 fps (14.6 m/s)

Emerson Process Management, Daniel Measurement and Control, Inc.,World Area Headquarters, Houston, Texas, USAT: 713-467-6000, F: 713-827-3880

USA Toll Free 1-888-FLOW-001

www.daniel.com

Calgary, Alberta, Canada Singapore - Asia PacificT: 403-279-1879, F: 403-236-1337 T: +65-6777-8211, F: +65-6770-8001

Stirling, Scotland - Europe, Mid-East, AfricaT: +44 (0) 1786 433400, F: +44 (0) 1786 433401

Daniel Measurement and Control, Inc. and Daniel Measurement Services, Inc.(collectively ”Daniel”) are a wholly owned subsidiaries of Emerson Electric Co., and divisions of Emerson Process Management. The Daniel logo is a registered trademark of Daniel Industries, Inc. The Emerson logo is a registered trademark and service mark of Emerson Electric Co. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time. Daniel does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Daniel product remains solely with the purchaser and end-user. The Daniel Liquid Ultrasonic Meter is protected by U.S. and International patents and patents pending.

Pressure Loss Chart - English Units

0.001

0.01

0.1

1

100 1000 10000 100000

Flow (GPM)

Loss

(psi

)

6” 8”

10”

10”

12”

16”

Specific gravity = 1

Meter

size

s (in

ches

) 4”

24”

20”

Flow Range and Pressure Loss