A.F.F.BRK'TBLKHDBTM.CLG.C.J.CONT.DSDWGS.E.J.EHELEC.EPEXIST.EXP.EXT.FDF.E.C.FIN.GYP. BD.HT.INT.JT.MFRMECH.MET.MTD.N.I.C.O.C.OPP.PTD.PT
ABOVE FINISHED FLOORBRACKETBULKHEADBOTTOMCEILINGCONTROL JOINTCONTINUOUSDOWN SPOUTDRAWINGSEXPANSION JOINTELECTRIC HEATER - SEE MECH. DWGS.ELECTRICALELEC. PANEL - SEE ELEC. DWGS.EXISTINGEXPOSEDEXTERIORFLOOR DRAINFIRE EXTINGUISHER CABINETFINISHEDGYPSUM BOARDHEIGHTINTERIORJOINTMANUFACTURERMECHANICALMETALMOUNTEDNOT IN CONTRACTON CENTEROPPOSITEPAINTEDPRESSURE TREATED
DRAWING INDEX
BRIDGEPORTHIGH SCHOOL
CANOPYREPLACEMENT
HARRISON COUNTY SCHOOLsBRIDGEPORT, WEST VIRGINIA
FILE MSES 16-1011
DATE 8/10/2016
REVISIONS
MULTI-PRIME CONTRACTORS:
CONTRACT A - GENERAL CONTRACTORCONTRACT B - CANOPY CONTRACTOR
1. ALL DIMENSIONS ARE NOMINAL TO FINISHEDMATERIALS U.N.O.
2. VERIFY EXIST. CONDITIONS & DIMENSIONS INFIELD BEFORE PROCEEDING WITHCONSTRUCTION. IMMEDIATELY REPORT ANYDISCREPANCIES TO ARCHITECT.
ELECTRICAL: (BY OWNER, PROVIDED FOR REFERENCE ONLY)
E101 ELECTRICAL DEMOLITION & LIGHTING PLAN
ARCHITECTURAL:
A101 FLOOR PLANSA601 SECTIONS, DETAILS & SCHEDULES
AUGUST 10, 2016
BRIDGEPORT HIGH SCHOOLCANOPY REPLACEMENTHARRISON COUNTY SCHOOLSBRIDGEPORT, WEST VIRGINIA
PROJECT LOCATION
VICINITY MAPN.T.S.
PROJECT SITE MAPN.T.S.
PROJECT LOCATION
GENERAL NOTES:ABBREVIATIONS:
SIM.SQ.STL.TBDT.O.M.TWUTSTYP.U.N.O.V.I.F.W/WD.
SIMILARSQUARESTEELTO BE DETERMINEDTOP OF MASONRYTHROUGH - WALL UNIT - SEE MECH. DWGS.TUBE STEELTYPICALUNLESS NOTED OTHERWISEVERIFY IN FIELDWITHWOOD
C
D
E
F
1 2 3 4 5 6 7
B
A
G
H
REMOVE EXISTINGDAMAGED TS COLUMN INIT'S ENTIRETY - TYP. (1)
REMOVE EXISTING TSCOLUMNS - CUT OFF MIN.4" BELOW SLAB - TYP. (4)
REMOVE EXISTING TSCOLUMNS - CUT OFF MIN.4" BELOW SLAB - TYP. (4)
REMOVE EXISTINGCANOPY & FRAMING IN ITSENTIRETY
REMOVE EXISTINGCANOPY & FRAMINGIN ITS ENTIRETY
10' -
8"
10' -
8"
11' -
0"
9' -
0"
11' -
0"
10' -
8"
10' -
8"
9' - 0" 11' - 0" 11' - 0" 11' - 0" 11' - 0" 11' - 0" 8' - 11 3/4"
EXISTING CONCRETESIDEWALK TO REMAIN
EXISTING BUILDING
REMOVEDOWNSPOUTS TOGRADE LEVEL
EXIST. RAMPTO REMAIN
EXISTING TS 4x4 COLUMNS TO REMAIN -TYP. (17). CUT & REMOVE TOPS OFCOLUMNS SO THEY ARE 8'-0" HIGH,EXCEPT FOR COLUMNS D2, E1, & E2WHICH SHALL REMAIN AT EXISTINGHEIGHT OF 10'-9"±
FA
CE
OF
BU
ILD
ING
C
D
E
F
1 2 3 4 5 6 7
1
A301
1
A301
2
A301
CONTRACT B - BID NO. 1:INTERNAL "FAN BEAM" WITHIN STRUCT.INSULATED PANELS - TYP. @ EA. LIGHTFIXTURE LOCATION TO BE USED AS ELEC.CONDUIT - TYP.CONTRACT B - BID NO. 2:OWNER TO PROVIDE UNISTRUT FRAMING ANDCONDUIT TO LIGHT FIXTURES
2' - 0" TO OF FAN BEAM (TYP.)
(TYP.)
4' - 0"
BEAMS AND CONNECTIONS TOTS COLUMNS BY CANOPY MFR.
LINE OF 4' WIDE STRUCTURALINSULATED ROOF PANELS - TYP.
EXISTING TS 4x4COLUMN (TYP.)
CL
EXIST. COLUMN (TYP.)
(2)
TS
4X
8
(2)
TS
4X
8
(2) TS 4X8
(2) TS 4X8
DS DS
DS
DS
DS
6' -
0"
6' -
0"
12' - 0" 12' - 0" 12' - 0" 12' - 0" 6' - 0"
SURFACE MOUNTED LIGHTFIXTURES BY OWNER
ALUM. SOFFIT CEILINGUNDER CONTRACT A -GENERAL CONTRACTOR
VENTED ALUM. SOFFITUNDER CONTRACT A -GENERAL CONTRACTOR
PTD. STL. BEAMSUNDER CONTRACTA - GENERALCONTRACTOR
CENTRAL CANOPYUNDER CONTRACT A -GENERAL CONTRACTOR
GUTTERS & DOWNSPOUTSBY CANOPY MFR. DOWN-SPOUT TO BE TIED INTOEXISTING STORM DRAIN ATGRADE BY OWNER - TYP.
C
D
E
F
1 2 3 4 5 6 7
1
A301
1
A301
2
A301
STANDING SEAM METAL ROOF -SEE DETAIL A ON A301UNDER CONTRACTA - GENERAL CONTRACTOR
SLOPE4:12
SLO
PE
4:12
SLOPE4:12
SLO
PE
4:12
LINE OF 4' WIDESTRUCTURAL INSULATEDROOF PANELS - TYP.
GUTTERS & DOWNSPOUTSBY CANOPY MFR. DOWN-SPOUT TO BE TIED INTOEXISTING STORM DRAIN ATGRADE BY OWNER - TYP.
DS DS
DS
DS
DS
DS TO MATCH CANOPYBELOW UNDER CONTRACT A -GENERAL CONTRACTOR
DS TO MATCH CANOPYBELOW UNDER CONTRACTA - GENERAL CONTRACTOR
CENTRAL CANOPYINCLUDING GUTTERS &TWO DOWNSPOUTS UNDERCONTRACTA - GENERAL CONTRACTOR
ICE GUARDS -TYP. (4)
C
D
E
F
1 2 3 4 5 6 7
11' -
0"
9' -
0"
11' -
0"
1
A301
1
A30113' -
0"
9' - 0" 11' - 0" 11' - 0" 11' - 0" 11' - 0" 11' - 0" 8' - 11 3/4"
11' -
0"
11' - 0"
1' - 0"1' - 0"
12' -
0"
2
A301
CANOPY DOWNSPOUT TOGRADE. DOWNSPOUT TO BETIED INTO EXISTING STORMDRAIN AT GRADE BY OWNER
ALL CONCRETE PATCHINGBY OWNER - TYP.
ALL CONCRETE PATCHINGBY OWNER - TYP.
CANOPY DOWNSPOUT TOGRADE. DOWNSPOUT TO BETIED INTO EXISTING STORMDRAIN AT GRADE - BY OWNER
EXISTING CONCRETESIDEWALK
A301B
EDGE OF CANOPY ABOVE - TYP.
CENTRAL CANOPYUNDER CONTRACT A -GENERALCONTRACTOR
FA
CE
OF
BU
ILD
ING
SAND, PRIME, & PAINT ALL REMAININGTUBE STEEL COLUMNS UNDER CONTRACTA - GENERAL CONTRACTOR
12' - 0"
1' - 3"
1' -
7 1
/8"
TCETIHCRA
DERETSIGE
R
STA
TEOF
WEST VIRG
INIA
PAMELA JO
WEAN
N0. 3331
DATE FILEAUG. 10, 2016
SHEET
#
BR
IDG
EP
OR
T H
IGH
SC
HO
OL
CA
NO
PY
RE
PLA
CE
ME
NT
BR
IDG
EP
OR
T, W
ES
T V
IRG
INIA
2016
MS
ES
AR
CH
ITE
CT
SC
MSES 16-1011
PLANS
A101
SCALE: 1/8" = 1'-0"DEMO PLAN
SCALE: 1/8" = 1'-0"REFLECTED CEILING PLAN
SCALE: 1/8" = 1'-0"ROOF PLAN
SCALE: 1/8" = 1'-0"FLOOR PLAN
16'8'4'0'N
CONTRACT B - BID NO. 1:
PROVIDE PRE-ENGINEERED STRUCTURAL INSULATEDROOF PANEL CANOPY SYSTEM UNDER CONTRACTB - CANOPY CONTRACTOR.
CONRTACT B - BID NO. 2:
PROVIDE PRE-ENGINEERED FLAT PAN ALUM. CANOPYSYSTEM UNDER CONTRACT B - CANOPY CONTRACTOR
ALL WORK SHOWN ON THIS PLAN TO BE PROVIDEDUNDER CONTRACT B - CANOPY CONTRACTOR, UNLESSNOTED OTHERWISE.
MULTI-PRIME CONTRACTORS:
CONTRACT A - GENERAL CONTRACTORCONTRACT B - CANOPY CONTRACTOR
ALL WORK SHOWN ON THIS PLAN TOBE PROVIDED UNDER CONTRACTB - CANOPY CONTRACTOR,UNLESS NOTED OTHERWISE.
ALL WORK SHOWN ON THIS PLAN TOBE PROVIDED UNDER CONTRACTB - CANOPY CONTRACTOR,UNLESS NOTED OTHERWISE.
• ALL ELECTRICAL DEMO AND NEW WORK BY OWNER.• ALL STORM DRAINAGE DEMO AND NEW WORK BELOW
GRADE BY OWNER• ALL CONCRETE PATCHING AT EXISTING SIDEWALK BY
OWNER
ALL WORK SHOWN ON THIS PLAN TO BE PROVIDEDUNDER CONTRACT A - GENERAL CONTRACTOR, UNLESSNOTED OTHERWISE.
REVISIONS
GENERAL INFO
1 2
3 4 5 6 7
2
A301
1' - 6" 1' - 6"
412
SURFACE MOUNTED LIGHTFIXTURES BY OWNER
LINE OF 4' WIDESTRUCTURAL INSULATEDPANELS - (TYP.)
EXIST. COLUMN (TYP.)
CENTRAL CANOPY UNDERCONTRACT A - GENERALCONTRACTOR
F1 BEYOND
CUT & REMOVE TOPS OFCOLUMNS TO BE 8' - 0" HIGH -UNDER CONTRACT A -GENERAL CONTRACTOR. SEEDEMO PLAN FOR LOCATIONS
SAND, PRIME ANDPAINT COLUMNSUNDER CONTRACT A
10 1
/4"
8' -
0"
CANOPY PANELS, FRAMING ANDCONNECTIONS UNDER CONTRACT B -CANOPY CONTRACTOR
CONTRACT B - NO. 1: INTERNAL FAN BOX/CONDUIT UNDERCONTRACT B - CANOPY CONTRACTORCONTRACT B - NO. 2:OWNER TO PROVIDE UNISTRUT FRAMING@ LIGHT FIXTURES
WORK POINT/BOTTOM OF TS BEAM
8' - 7"±(COORDINATE TO ALIGN W/TOP OF CANOPY FRAMING)
T/ SIDEWALK0' - 0"
TOP OF COLUMN10' - 9"± V.I.F.
1
A301
A301A
412
A301D
SURFACE MOUNTED LIGHTFIXTURE - BY OWNER
FRAME
EQ. EQ. EQ. EQ.
F1 BEYOND
CENTRAL CANOPYUNDER CONTRACT A -GENERALCONTRACTOR
8' -
0"
CO
NT
RA
CT
BC
AN
OP
Y C
ON
TR
AC
TO
R
F1
TOP OF COLUMN10' - 9"± V.I.F.
WORK POINT/BOTTOM OF TS BEAM
8' - 7"±(COORDINATE TO ALIGN W/TOP OF CANOPY FRAMING)
T/ SIDEWALK0' - 0"
TYP.
C D E F
SEE TYP. NOTESON SECT. 1/A301
ALUM. FASCIA OVERPT 2X8 FASCIA BOARD
CONT. GUTTER &DOWNSPOUT TO SPILLOUT ON CANOPY BELOW
PT 2X4 TOP PLATE BOLTEDTO TS 4X8 BEAM
STANDING SEAM METAL ROOFINGOVER SLIP SHEET OVER 3/4" EXTERIORGRADE PLYWOOD SUBSTRATE
RIDGE/HIPFLASHING
TS 4X8X1/4" BEAMWELDED TO SIDEOF COLUMNS - TYP.
DOUBLE 6" FULLY VENTEDALUMINUM SOFFIT W/J TRIM @ BOTH ENDS
PAINTED H.M. FRAME.SHIM AND CAULK AS NECESSARY
412
STRUCTURAL INSUL. PANELS,BEAMS AND CONNECTIONSUNDER CONTRACT B -CANOPY CONTRACTOR
F1
DOUBLE 6" SOLIDALUM. SOFFIT
SURFACE MOUNTEDLIGHT FIXTURE BYOWNER
TOP OF COLUMN10' - 9"± V.I.F.
WORK POINT/BOTTOM OF TS BEAM
8' - 7"±(COORDINATE TO ALIGN W/TOP OF CANOPY FRAMING)
ALL WORK SHOWN ON THIS DETAIL TO BEPROVIDED UNDER CONTRACT A - GENERALCONTRACTOR, UNLESS NOTED OTHERWISE
PTD. TS 4X4X1/4"BEYOND
2X6
2X6
1' - 6"
ALUM.TRIM
ICE GUARDS - 4 SIDES
1/4" TEMP.GL.
1
1' - 0"
1' -
0"
TS 4X4X1/4" COLUMN W/8X8X3/8" BASE PLATE
EXISTING CONC.SIDEWALK
C
A301
1"CL
1/2" HILTY EPOXY ANCHORBOLTS - DRILLED INTOEXIST. CONC. 6"
EXIST. CONC. PIER SIZE ISASSUMED - VERIFY INFIELD & CONTACT ARCH. IFCONDITIONS VARY.
OWNER WILL PATCHSURROUNDING CONC.SIDEWALK
D
STRUCT. INSUL. PANELS, BEAMS &CONNECTIONS UNDER CONTRACT B -CANOPY CONTRACTOR
GUTTER SYSTEM BY CANOPY MFR.DOWNSPOUT TO BE TIED INTOEXISTING STORM DRAIN @ GRADEBY OWNER
BOX BEAM BY CANOPY MFR.
EXISTING COLUMN CUTTO 8' - 0" HIGH UNDERCONTRACT A - GENERALCONTRACTOR
WORK POINT/BOTTOM OF TS BEAM
8' - 7"±(COORDINATE TO ALIGN W/TOP OF CANOPY FRAMING
1
TS 4x4x1/4" COLUMN - WELDTO 8X8X3/8" BASE PLATE
CONCRETE PIERFOUNDATION @ ELEV. -4"±
CL
COAT ALL STEEL BELOWSLAB W/ HEAVY LAYER OFTAR EMULSION
EXIST. CONC. PIER SIZE ISASSUMED - VERIFY INFIELD & CONTACT ARCH. IFCONDITIONS VARY.
1/2"x1/4" SILICONE CAULKBY OWNER
1/2"x4" CLOSED CELLPOLYPROPYLENE W/1/4" TEAR AWAY TOP -BY OWNER
T/ SIDEWALK0' - 0"
OWNER WILL PATCHCONC. SIDEWALK
1/2" HILTY EPOXYANCHOR BOLTS -DRILLED INTO EXIST.CONC. 6"
X
V.I.F.
9' - 0" ±
2"2"
1/4" TEMP. GLASS
X
2" T
YP
.
10' -
9"±
V.I.
F.
F1 HM FRAME - TYP. 4
PRIME & PAINT
V.I.
F.
1' -
6"
TCETIHCRA
DERETSIGE
R
STA
TEOF
WEST VIRG
INIA
PAMELA JO
WEAN
N0. 3331
DATE FILEAUG. 10, 2016
SHEET
#
BR
IDG
EP
OR
T H
IGH
SC
HO
OL
CA
NO
PY
RE
PLA
CE
ME
NT
BR
IDG
EP
OR
T, W
ES
T V
IRG
INIA
2016
MS
ES
AR
CH
ITE
CT
SC
MSES 16-1011
SECTIONS & DETAILS
A301
SCALE: 1/4" = 1'-0"A301
1 SECTION
SCALE: 1/4" = 1'-0"A301
2 SECTIONSCALE: 3/4" = 1'-0"A301
A DETAIL
SCALE: 3/4" = 1'-0"A301
B POST DETAIL3D ELEVATIONSCALE: 3/4" = 1'-0"A301
D DETAIL
0' 2' 4' 8'
0' 2' 4' 8' 2'1'0'
2'1'0'SCALE: 3/4" = 1'-0"A301
C COLUMN DETAIL3D ELEVATION
SCALE: 1/4" = 1'-0"FRAME TYPE
ALL WORK SHOWN ON THIS DETAIL TO BE PROVIDEDUNDER CONTRACT B - CANOPY CONTRACTOR, UNLESSNOTED OTHERWISE
ALL WORK SHOWN ON THIS DETAIL TO BE PROVIDEDUNDER CONTRACT A - GENERAL CONTRACTOR,UNLESS NOTED OTHERWISE
ALL WORK SHOWN ON THIS DETAIL TO BE PROVIDEDUNDER CONTRACT A - GENERAL CONTRACTOR,UNLESS NOTED OTHERWISE
ALL WORK SHOWN ON THIS DETAIL TO BE PROVIDEDUNDER CONTRACT A - GENERAL CONTRACTOR,UNLESS NOTED OTHERWISE
REVISIONS
NOTE:DETAILS OF CONTRACT B CANOPY AREDRAWN AND NOTED ON THIS DRAWINGAS STRUCTURAL INSUL. PANELS (BIDNO.1) SIMILAR CONDITIONS APPLYUNDER CONTRACT B - BID NO. 2
C1
C1
C1
C1 C1 C1 C1 C1
11111
1
1
3
3
4
4
33 3
4 44 4
2 2 2 2 2
2
2
5
C1
C1
C1
C1 C1 C1 C1 C1
2
2
3
3
22 2
3 33 3
1 1 1 1 1
1
1
4
REMOVE EXISTING LIGHT FIXTURE. EXISTINGWIRING IS ROUTED TO FIXTURE THRUCOLUMN. REMOVE WIRING BACK TO SOURCE.
REMOVE EXPOSEDJUNCTION BOXES,
CONDUIT AND WIRINGBACK TO SOURCE.
REMOVE EXISTING LIGHT FIXTURE.REMOVE ASSOCIATED BOX,CONDUIT AND WIRING BACK TOSOURCE UNLESS BEING REUSED.
REMOVE EXISTING LIGHT FIXTURE.EXISTING WIRING IS ROUTED TO
FIXTURE THRU COLUMN. REMOVEWIRING BACK TO SOURCE.
REMOVE EXISTING LIGHT FIXTURE.REMOVE ASSOCIATED WIRING
BACK TO SOURCE. PROVIDEBLANK FACEPLATE OVER BOX.
REMOVE EXISTING LIGHT FIXTURE. REMOVEASSOCIATED BOX, CONDUIT AND WIRING
BACK TO SOURCE UNLESS BEING REUSED.
REMOVE EXISTING LIGHT FIXTURE.REMOVE ASSOCIATED BOX,CONDUIT AND WIRING BACK TOSOURCE UNLESS BEING REUSED.
DATE FILEAUG. 10, 2016
SHEET
#
BR
IDG
EP
OR
T H
IGH
SC
HO
OL
CA
NO
PY
RE
PLA
CE
ME
NT
BR
IDG
EP
OR
T, W
ES
T V
IRG
INIA
*FOR
REFERENCE
ONLY*
2016
MS
ES
AR
CH
ITE
CT
SC
MSES 16-1011
ELECTRICAL PLAN
E101
ELECTRICAL GENERAL NOTES
1 ALL ELECTRICAL WORK SHALL BE IN COMPLIANCE WITH THE CURRENT EDITION OF THE NATIONAL ELECTRIC CODE ADOPTED BY THE STATE OF WEST VIRGINIA.2 ALL ELECTRICAL WORK SHALL BE PERFORMED BY ELECTRICIANS LICENSED BY THE STATE OF WEST VIRGINIA.
1/8" = 1'-0"1 LIGHTING PLAN (IF CONTRACT B - BID NO.1 IS ACCEPTED)
1/8" = 1'-0"3 LIGHTING PLAN (IF CONTRACT B - BID NO.2 IS ACCEPTED)
1/8" = 1'-0"2 ELECTRICAL DEMOLITION PLAN
LIGHT FIXTURE SCHEDULE
TYPE MANUFACTURER CATALOG DESIGNATION DESCRIPTIONLAMPS VOLTAGE WATTAGE
C1 120VLITHONIA LED 16.6W OLCFM-15-4000K-WH ROUND EXTERIOR SURFACE MOUNTED LED CANOPY FIXTURE
LIGHTING KEYNOTES (IF CONTRACT B - BID NO.1 IS ACCEPTED)
1 SECURE LIGHT FIXTURE TO FAN BEAMS. SEE SHEET A101 FOR FAN BEAM LOCATIONS. COORDINATE WITH CANOPY PROVIDER.2 ROUTE CONDUCTORS CONCEALED IN FAN BEAM RACEWAY FROM SURFACE RACEWAY OUT TO LIGHT FIXTURE. COORDINATE WITH CANOPY PROVIDER.3 PROVIDE JUNCTION BOX AT COLUMN. PROVIDE (3) #12 CONDUCTORS TO EXTEND EXISTING CIRCUIT FROM COLUMN TO NEW LIGHT FIXTURE.4 PROVIDE SURFACE METAL RACEWAY TO ROUTE CONDUCTORS FROM COLUMN TO FAN BEAM. PAINT SURFACE RACEWAY TO MATCH CANOPY SURFACE.5 EXTEND EXISTING CIRCUIT FROM NEAREST COLUMN TO LIGHT FIXTURE LOCATION. ROUTE CONDUCTORS IN 3/4" CONDUIT CONCEALED ABOVE CEILING.
#
LIGHTING KEYNOTES (IF CONTRACT B - BID NO.2 IS ACCEPTED))
1 PROVIDE UNISTRUT BETWEEN BEAMS TO MOUNT LIGHT FIXTURES. ROUTE CONDUCTORS CONCEALED IN UNISTRUT FROM SURFACE RACEWAY OUT TO LIGHTFIXTURE. PROVIDE CLOSURE STRIP ON FULL LENGTH OF UNISTRUT. PAINT TO MATCH CANOPY CEILING.
2 PROVIDE JUNCTION BOX AT COLUMN. PROVIDE (3) #12 CONDUCTORS TO EXTEND EXISTING CIRCUIT FROM COLUMN TO NEW LIGHT FIXTURE.3 PROVIDE SURFACE METAL RACEWAY TO ROUTE CONDUCTORS FROM COLUMN TO UNISTRUT. PAINT SURFACE RACEWAY TO MATCH CANOPY SURFACE.4 EXTEND EXISTING CIRCUIT FROM NEAREST COLUMN TO LIGHT FIXTURE LOCATION. ROUTE CONDUCTORS IN 3/4" CONDUIT CONCEALED ABOVE CEILING.
#
ALL ELECTRICAL WORK SHALL BE BY OWNER. THISSHEET IS FOR REFERENCE AND COORDINATIONONLY. CONTRACTORS SHALL COORDINATE ALLCANOPY WORK WITH OWNER'S ELECTRICIANS.
REVISIONS