8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
1/82
BreezeMAX TDD
Traps and Alarms
SW Version 4.5May 2008P/N: 214981
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
2/82
ii Traps and Alarms
Document History
Document History
Topic Description Date Issued
New Product Release SW Version
4.0.1, October
2006
rbOduFailureOn/Off ,
rbAUHoldOverTxStoppedOn/Of
f Traps
New Traps SW Version
4.0.2, Decmber
2006
OduFailureOn and
AUHoldOverTxStoppedOn
Alarms
New Alarms SW Version
4.0.2, Decmber
2006
Service related traps
Section 5.8
Trap source of rbServiceDown,
rbServiceUp, rbServiceChanged and
rbServiceGeneralError has been
changed to BST/NPU.
SW Version
4.1.1, April
2007
rbOptimalRSSIConflict Trap
Section 5.1.9
New Trap SW Version
4.1.1, April
2007
BER Test Traps
Section 5.6.6, Section 5.6.7
BER Test is not supported by current
release
SW Version
4.1.1, April2007
rbAUHoldOverTxStoppedOn
and
rbAUHoldOverTxStoppedOff
Traps
Section 5.10.21,
Section 5.10.22
Traps are supported. SW Version
4.1.1, April
2007
rbLicenseFileLoadStatus Trap
Section 5.3.5
Updated list of Additional Info (added
192-195, updated description of 188).
SW Version
4.1.1, April2007
rbMbstLicenseChanged,
rbCPELicenseAssigned Traps
Section 5.3.6, Section 5.3.7
New Traps SW Version
4.1.1, April
2007
rbIPCSModeConfigurationError
Trap
Section 5.12.1
New Trap SW Version
4.1.1, April
2007
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
3/82
Traps and Alarms iii
Document History
rbBackupFileSwitchingModeMi
smatchSection 5.3.8
New Trap SW Version
4.1.1, April2007
rbSwSwitchFailed and
rbFreqBandDownloadResult
Traps Additional Info
Table 1-68
Added Additional Info 219 SW Version
4.1.1, April
2007
Micro Base Station Support for
all applicable traps
New product SW Version 4.2
June 2007
PF Server Related Traps
Section 5.13
New (not supported in current release) SW Version 4.2
June 2007
PFSereverKeepAliveTimeoutOn
Alarm
Section 6.28
New (not supported in current release) SW Version 4.2
June 2007
Binding Parameters Added description SW Version 4.5
March 2008
Traps and Alarm Sources
Sections 5.3.1
Updated SW Version 4.5
March 2008
Binding parameters
Sections 5.1.2, 5.1.4, 5.1.5,
5.1.9, 5.3.2, 5.3.4, 5.3.6, 5.3.7,
5.4.1, 5.4.2, 5.4.3, 5.4.4, 5.4.5,
5.4.6, 5.4.7, 5.5.1, 5.5.2, 5.5.5,
5.8.1, 5.8.2, 5.8.3, 5.8.4, 5.9.3,
5.9.4, 5.9.5, 5.9.6, 5.9.7, 5.9.8,
5.9.9, 5.13.1, 5.13.2
Updated details of binding parameters
are provided separately.
SW Version 4.5
March 2008
ODU Related Traps
Section 5.4
rbOduConfigId added as a binding
parameter to all ODU related traps
SW Version 4.5
March 2008
rbOduFailureOn Trap
Section 5.4.6
rbOduStatusMask added as binding
parameter to rbOduFailureOn trap.
SW Version 4.5
March 2008
rbBSPmTmLastFileName Trap
Section 5.3.9
New trap SW Version 4.5
March 2008
rbSwSwitchSucceed Trap
Section 5.6.5
Updated Additional Info SW Version 4.5
March 2008
rbGPSSysUpDateAndTime Trap
Section 5.10.23
New trap SW Version 4.5
March 2008
Topic Description Date Issued
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
4/82
iv Traps and Alarms
Document History
Spectrum Analyzer Related
TrapsSection 5.11
New Trap SW Version 4.5
March 2008
PF Server Related Traps
Section 5.13
Applicable for NPU and supported by
release
SW Version 4.5
March 2008
ShelfCardExtractionOn Alarm
Section 6.4
Updated Alarm sources SW Version 4.5
March 2008
PFSereverKeepAliveTimeoutOn
Alarm
Section 6.28
Applicable for NPU and supported by
release
SW Version 4.5
March 2008
Topic Description Date Issued
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
5/82
Traps and Alarms i
Legal Rights
Legal Rights
Copyright 2007 Alvarion Ltd. All rights reserved.
The material contained herein is proprietary, privileged, and confidential and
owned by Alvarion or its third party licensors. No disclosure thereof shall be made
to third parties without the express written permission of Alvarion Ltd.
Alvarion Ltd. reserves the right to alter the equipment specifications and
descriptions in this publication without prior notice. No part of this publication
shall be deemed to be part of any contract or warranty unless specifically
incorporated by reference into such contract or warranty.
Trade Names
Alvarion
, BreezeCOM
, WALKair
, WALKnet
, BreezeNET
, BreezeACCESS
,BreezeMANAGE, BreezeLINK, BreezeConfig, BreezeMAX, AlvariSTAR,
BreezeLITE, AlvariCRAFT, MGW, eMGW, and/or other products and/or
services referenced here in are either registered trademarks, trademarks or
service marks of Alvarion Ltd.
All other names are or may be the trademarks of their respective owners.
Statement of Conditions
The information contained in this manual is subject to change without notice.
Alvarion Ltd. shall not be liable for errors contained herein or for incidental orconsequential damages in connection with the furnishing, performance, or use of
this manual or equipment supplied with it.
Warranties and Disclaimers
All Alvarion Ltd. ("Alvarion") products purchased from Alvarion or through any of
Alvarion's authorized resellers are subject to the following warranty and product
liability terms and conditions.
Exclusive Warranty
(a) Alvarion warrants that the Product hardware it supplies and the tangible
media on which any software is installed, under normal use and conditions, will
be free from significant defects in materials and workmanship for a period of
fourteen (14) months from the date of shipment of a given Product to Purchaser
(the "Warranty Period"). Alvarion will, at its sole option and as Purchaser's sole
remedy, repair or replace any defective Product in accordance with Alvarion'
standard R&R procedure.
(b) With respect to the Firmware, Alvarion warrants the correct functionality
according to the attached documentation, for a period of fourteen (14) month from
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
6/82
ii Traps and Alarms
Legal Rights
invoice date (the "Warranty Period")". During the Warranty Period, Alvarion may
release to its Customers firmware updates, which include additional performance
improvements and/or bug fixes, upon availability (the "Warranty"). Bug fixes,
temporary patches and/or workarounds may be supplied as Firmware updates.
Additional hardware, if required, to install or use Firmware updates must be
purchased by the Customer. Alvarion will be obligated to support solely the two (2)
most recent Software major releases.
ALVARION SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING
AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT
DOES NOT EXIST OR WAS CAUSED BY PURCHASER'S OR ANY THIRD
PERSON'S MISUSE, NEGLIGENCE, IMPROPER INSTALLATION OR IMPROPER
TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR, OR ANY OTHER CAUSE
BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE,
LIGHTNING OR OTHER HAZARD.
Disclaimer
(a) The Software is sold on an "AS IS" basis. Alvarion, its affiliates or its licensors
MAKE NO WARRANTIES, WHATSOEVER, WHETHER EXPRESS OR IMPLIED,
WITH RESPECT TO THE SOFTWARE AND THE ACCOMPANYING
DOCUMENTATION. ALVARION SPECIFICALLY DISCLAIMS ALL IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE AND NON-INFRINGEMENT WITH RESPECT TO THE SOFTWARE.
UNITS OF PRODUCT (INCLUDING ALL THE SOFTWARE) DELIVERED TO
PURCHASER HEREUNDER ARE NOT FAULT-TOLERANT AND ARE NOT
DESIGNED, MANUFACTURED OR INTENDED FOR USE OR RESALE IN
APPLICATIONS WHERE THE FAILURE, MALFUNCTION OR INACCURACY OF
PRODUCTS CARRIES A RISK OF DEATH OR BODILY INJURY OR SEVERE
PHYSICAL OR ENVIRONMENTAL DAMAGE ("HIGH RISK ACTIVITIES"). HIGH
RISK ACTIVITIES MAY INCLUDE, BUT ARE NOT LIMITED TO, USE AS PART OF
ON-LINE CONTROL SYSTEMS IN HAZARDOUS ENVIRONMENTS REQUIRING
FAIL-SAFE PERFORMANCE, SUCH AS IN THE OPERATION OF NUCLEAR
FACILITIES, AIRCRAFT NAVIGATION OR COMMUNICATION SYSTEMS, AIR
TRAFFIC CONTROL, LIFE SUPPORT MACHINES, WEAPONS SYSTEMS OR
OTHER APPLICATIONS REPRESENTING A SIMILAR DEGREE OF POTENTIAL
HAZARD. ALVARION SPECIFICALLY DISCLAIMS ANY EXPRESS OR IMPLIED
WARRANTY OF FITNESS FOR HIGH RISK ACTIVITIES.
(b) PURCHASER'S SOLE REMEDY FOR BREACH OF THE EXPRESS
WARRANTIES ABOVE SHALL BE REPLACEMENT OR REFUND OF THE
PURCHASE PRICE AS SPECIFIED ABOVE, AT ALVARION'S OPTION. TO THE
FULLEST EXTENT ALLOWED BY LAW, THE WARRANTIES AND REMEDIES SET
FORTH IN THIS AGREEMENT ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
7/82
Traps and Alarms iii
Legal Rights
WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY
OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING BUT NOT
LIMITED TO WARRANTIES, TERMS OR CONDITIONS OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, SATISFACTORY QUALITY,CORRESPONDENCE WITH DESCRIPTION, NON-INFRINGEMENT, AND
ACCURACY OF INFORMATION GENERATED. ALL OF WHICH ARE EXPRESSLY
DISCLAIMED. ALVARION' WARRANTIES HEREIN RUN ONLY TO PURCHASER,
AND ARE NOT EXTENDED TO ANY THIRD PARTIES. ALVARION NEITHER
ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY
OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION,
MAINTENANCE OR USE OF ITS PRODUCTS.
Limitation of Liability
(a) ALVARION SHALL NOT BE LIABLE TO THE PURCHASER OR TO ANY THIRDPARTY, FOR ANY LOSS OF PROFITS, LOSS OF USE, INTERRUPTION OF
BUSINESS OR FOR ANY INDIRECT, SPECIAL, INCIDENTAL, PUNITIVE OR
CONSEQUENTIAL DAMAGES OF ANY KIND, WHETHER ARISING UNDER
BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY
OR OTHERWISE AND WHETHER BASED ON THIS AGREEMENT OR
OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
(b) TO THE EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL
THE LIABILITY FOR DAMAGES HEREUNDER OF ALVARION OR ITS EMPLOYEES
OR AGENTS EXCEED THE PURCHASE PRICE PAID FOR THE PRODUCT BYPURCHASER, NOR SHALL THE AGGREGATE LIABILITY FOR DAMAGES TO ALL
PARTIES REGARDING ANY PRODUCT EXCEED THE PURCHASE PRICE PAID
FOR THAT PRODUCT BY THAT PARTY (EXCEPT IN THE CASE OF A BREACH OF
A PARTY'S CONFIDENTIALITY OBLIGATIONS).
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
8/82
iv Traps and Alarms
Legal Rights
Important Notice
This user manual is delivered subject to the following conditions and restrictions:
This manual contains proprietary information belonging to Alvarion Ltd. Such
information is supplied solely for the purpose of assisting properly authorized
users of the respective Alvarion products.
No part of its contents may be used for any other purpose, disclosed to any
person or firm or reproduced by any means, electronic and mechanical,
without the express prior written permission of Alvarion Ltd.
The text and graphics are for the purpose of illustration and reference only.
The specifications on which they are based are subject to change withoutnotice.
The software described in this document is furnished under a license. The
software may be used or copied only in accordance with the terms of that
license.
Information in this document is subject to change without notice. Corporate
and individual names and data used in examples herein are fictitious unless
otherwise noted.
Alvarion Ltd. reserves the right to alter the equipment specifications and
descriptions in this publication without prior notice. No part of this
publication shall be deemed to be part of any contract or warranty unless
specifically incorporated by reference into such contract or warranty.
The information contained herein is merely descriptive in nature, and does not
constitute an offer for the sale of the product described herein.
Any changes or modifications of equipment, including opening of the
equipment not expressly approved by Alvarion Ltd. will void equipmentwarranty and any repair thereafter shall be charged for. It could also void the
user's authority to operate the equipment.
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
9/82
Contents
Chapter 1 - Traps and Alarms Structure..................................................1
Chapter 2 - Traps and Alarms Sources ....................................................1
Chapter 3 - Traps and Alarms Severities.................................................3
Chapter 4 - Trap/Alarm Categories ..........................................................4
Chapter 5 - BreezeMAX Traps .................................................................. 5
5.1 General Traps ............................................................................................................5
5.1.1 rbResetOn Trap................................................................................................5
5.1.2 rbDiagnosticsHwFaultOn Trap .........................................................................6
5.1.3 rbDiagnosticsHwFaultOff Trap .........................................................................7
5.1.4 rbMonitorAccessOn Trap .................................................................................8
5.1.5 rbMonitorAccessOff Trap .................................................................................8
5.1.6 rbAuNetworkEntryStatus Trap..........................................................................9
5.1.7 rbModeConflictOn Trap....................................................................................9
5.1.8 rbModeConflictOff Trap..................................................................................10
5.1.9 rbOptimalRSSIConflict Trap...........................................................................11
5.2 Chassis/Micro Base Station Related Traps...........................................................11
5.2.1 rbShelfCardExtractionOn Trap.......................................................................11
5.2.2 rbShelfCardInsertionOn Trap .........................................................................11
5.2.3 rbShelfPeripheralEquipmentFaultOn Trap .....................................................13
5.2.4 rbShelfPeripheralEquipmentFaultOff Trap .....................................................13
5.2.5 rbShelfEnvParamFaultOn Trap......................................................................14
5.2.6 rbShelfEnvParamFaultOff Trap......................................................................15
5.3 NPU/Micro Base Station Related Traps .................................................................15
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
10/82
vi Traps and Alarms
Contents
5.3.1 rbConfigurationChanged Trap........................................................................15
5.3.2 rbParameterSetFailure Trap...........................................................................16
5.3.3 rbMbstLicense Trap........................................................................................18
5.3.4 rbMbstCPEQuantityExceed Trap ...................................................................19
5.3.5 rbLicenseFileLoadStatus Trap .......................................................................19
5.3.6 rbMbstLicenseChanged Trap.........................................................................20
5.3.7 rbCPELicenseAssigned Trap .........................................................................20
5.3.8 rbBackupFileSwitchingModeMismatch Trap ..................................................20
5.3.9 rbLastPmTmFileName Trap...........................................................................21
5.4 ODU Related Traps ..................................................................................................21
5.4.1 rbOduCommErrorOn Trap..............................................................................21
5.4.2 rbOduCommErrorOff Trap..............................................................................21
5.4.3 rbOduBandMissmatchOn Trap.......................................................................23
5.4.4 rbOduBandMissmatchOff Trap.......................................................................23
5.4.5 rbOduPowerMissmatch Trap..........................................................................24
5.4.6 rbOduFailureOn Trap .....................................................................................24
5.4.7 rbOduFailureOff Trap .....................................................................................26
5.5 SU Related Traps .....................................................................................................26
5.5.1 rbSuMaxTxPowerReached Trap....................................................................26
5.5.2 rbSuMinTxPowerReached Trap.....................................................................26
5.5.3 rbSuNetworkEntryStatus Trap........................................................................27
5.5.4 rbSuLicense Trap...........................................................................................27
5.5.5 rbSuDuplicateName Trap...............................................................................29
5.6 Software Download and BER Test Related Traps ................................................29
5.6.1 rbSwDownloadStart Trap ...............................................................................29
5.6.2 rbSwDownloadEnd Trap ................................................................................29
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
11/82
Traps and Alarms vii
Contents
5.6.3 rbSwDownloadError Trap...............................................................................30
5.6.4 rbSwSwitchFailed Trap ..................................................................................32
5.6.5 rbSwSwitchSucceed Trap ..............................................................................32
5.6.6 rbBERTestFinished Trap................................................................................32
5.6.7 rbBERTestStarted Trap..................................................................................34
5.6.8 rbSwFileConflict Trap.....................................................................................34
5.7 File Download Related Traps..................................................................................34
5.7.1 rbXMLDownloadResult Trap ..........................................................................34
5.7.2 rbFreqBandDownloadResult Trap..................................................................35
5.8 Service Related Traps .............................................................................................35
5.8.1 rbServiceDown Trap.......................................................................................35
5.8.2 rbServiceUp Trap ...........................................................................................36
5.8.3 rbServiceChanged Trap .................................................................................36
5.8.4 rbServiceGeneralError Trap...........................................................................37
5.8.5 rbNetworkingError Trap..................................................................................38
5.9 RADIUSs Related Traps ..........................................................................................38
5.9.1 rbSwitchedAuthenticationServer Trap............................................................38
5.9.2 rbSwitchedAccountingServer Trap.................................................................38
5.9.3 rbServiceEstablishmentFailure Trap ..............................................................39
5.9.4 rbUserAuthenticationTimeout Trap ................................................................40
5.9.5 rbUserAuthenticationReject Trap ...................................................................40
5.9.6 rbAuthenticationServerKeepAliveTimeoutOn Trap ........................................ 40
5.9.7 rbAuthenticationServerKeepAliveTimeoutOff Trap ........................................41
5.9.8 rbAccountingServerKeepAliveTimeoutOn Trap .............................................41
5.9.9 rbAccountingServerKeepAliveTimeoutOff Trap .............................................41
5.10 GPS Related Traps ..................................................................................................42
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
12/82
viii Traps and Alarms
Contents
5.10.1 rbExternal1PPSFailureOn Trap......................................................................42
5.10.2 rbExternal1PPSFailureOff Trap......................................................................42
5.10.3 rbInternal1PPSFailureOn Trap.......................................................................42
5.10.4 rbInternal1PPSFailureOff Trap.......................................................................43
5.10.5 rbExternal16MHzFailureOn Trap ...................................................................43
5.10.6 rbExternal16MHzFailureOff Trap ...................................................................43
5.10.7 rbInternal16MHzFailureOn Trap.....................................................................44
5.10.8 rbInternal16MHzFailureOff Trap.....................................................................44
5.10.9 rbGPSComFailureOn Trap.............................................................................44
5.10.10 rbGPSComFailureOff Trap.............................................................................45
5.10.11 rbGPSHealthyFailureOn Trap ........................................................................45
5.10.12 rbGPSHealthyFailureOff Trap ........................................................................45
5.10.13 rbMin4SatSyncFailureOn Trap.......................................................................46
5.10.14 rbMin4SatSyncFailureOff Trap.......................................................................46
5.10.15 rbAUExternal1PPSFailureOn Trap.................................................................46
5.10.16 rbAUExternal1PPSFailureOff Trap.................................................................47
5.10.17 rbAUHoldOverEnteredOn Trap......................................................................47
5.10.18 rbAUHoldOverEnteredOff Trap......................................................................47
5.10.19 rbAUHoldOverTimeoutPassedOn Trap..........................................................48
5.10.20 rbAUHoldOverTimeoutPassedOff Trap..........................................................48
5.10.21 rbAUHoldOverTxStoppedOn Trap .................................................................48
5.10.22 rbAUHoldOverTStoppedOff Trap...................................................................49
5.10.23 rbGPSSysUpDateAndTime Trap....................................................................49
5.11 Spectrum Analyzer Related Traps .........................................................................49
5.11.1 rbAUSpecAnalyzerTestStatus Trap ...............................................................49
5.12 IP CS Mode Configuration Related Traps..............................................................50
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
13/82
Traps and Alarms ix
Contents
5.12.1 rbIPCSModeConfigurationError Trap.............................................................50
5.13 PF Server Related Traps ......................................................................................... 51
5.13.1 rbPFSereverKeepAliveTimeoutOn Trap.........................................................51
5.13.2 rbPFSereverKeepAliveTimeoutOff Trap.........................................................51
5.14 MIB II Traps .............................................................................................................. 52
5.14.1 coldStart Trap.................................................................................................52
5.14.2 warmStart Trap...............................................................................................52
5.14.3 linkDown Trap ................................................................................................52
5.14.4 linkUp Trap.....................................................................................................53
5.14.5 authenticationFailure Trap..............................................................................54
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
14/82
x Traps and Alarms
Contents
Chapter 6 - Active Alarms ......................................................................54
6.1 DiagnosticsHwFaul tOn Alarm ................................................................................54
6.2 MonitorAccessOn Alarm.........................................................................................55
6.3 ModeConfl ictOn Alarm............................................................................................55
6.4 ShelfCardExt ract ionOn Alarm ................................................................................55
6.5 ShelfPeripheralEquipmentFaultOn Alarm .............................................................56
6.6 ShelfEnvParamFaultOn Alarm................................................................................56
6.7 OduCommErrorOn Alarm .......................................................................................57
6.8 OduBandMissmatchOn Alarm................................................................................57
6.9 OduFailureOn Alarm ...............................................................................................57
6.10 SwDownloadStart Alarm .........................................................................................58
6.11 SwDownloadError Alarm ........................................................................................58
6.12 SwSwitchFailed Alarm ............................................................................................58
6.13 AuthenticationServerKeepAliveTimeoutOn Alarm...............................................59
6.14 AccountingServerKeepAliveTimeoutOn Alarm ....................................................59
6.15 LinkDown Alarm ......................................................................................................59
6.16 AuthenticationFailure Alarm...................................................................................60
6.17 External1PPSFailureOn Alarm ...............................................................................60
6.18 Internal1PPSFailureOn Alarm.................................................................................61
6.19 External16MHzFailureOn Alarm .............................................................................61
6.20 Internal16MHzFailureOn Alarm ..............................................................................62
6.21 GPSComFailureOn Alarm .......................................................................................62
6.22 GPSHealthyFailureFailureOn Alarm ......................................................................62
6.23 Min4SatSyncFailureFailureOn Alarm.....................................................................63
6.24 AUExternal1PPSFailureOn Alarm ..........................................................................63
6.25 AUHoldOverEnteredOn Alarm................................................................................63
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
15/82
Traps and Alarms xi
Contents
6.26 AUHoldOverTimeoutPassedOn Alarm...................................................................64
6.27 AUHoldOverTxStoppedOn Alarm...........................................................................64
6.28 PFSereverKeepAliveTimeoutOn Alarm ................................................................. 65
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
16/82
xii Traps and Alarms
Contents
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
17/82
Traps and Alarms Structure
Traps and Alarms 1
1 Traps and Alarms Structure
A BreezeMAX trap/alarm includes the following variables:
2 Traps and Alarms Sources
The trap/alarm source indicates the device that originated the trap/alarm. Each
trap/alarm message should include the full hierarchy of its source.
Possible sources and associated information are:
NPU: (Slot#=5).
AU:
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
18/82
2 Traps and Alarms
Traps and Alarms Sources
AVU FAN: (Slot# = 1-10)
Service: Identified through binding parameters rather than the source. The
binding parameters used to identify a Service are: Service Index, Service
Name, Subscriber Index, and Subscriber ID.
The following are used as Sources only for the rbConfigurationChanged TRAP:
BTS Sector:
ODU:
Channel:
Subscriber:
Service:
Priority Classifier:
QoS Profile:
Forwarding Rule:
Service Profile:
Layer 2 Filtering Rule:
Layer 3/4 Filtering Rule:
Figure 1-1: Base Station's Chassis Slots Assignment
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
19/82
Traps and Alarms Severities
Traps and Alarms 3
Interface Filter:
Filtering Rule:
MAC Address Deny List:
Autorized Manager:
Traps:
Authentication Server:
Accounting Server: ,
Voice Domain:
PF Server:
PF General:
Service Group:
3 Traps and Alarms Severities
The trap/alarm severity level indicates how the capability of the managed object
has been affected. It represents the severity of the alarm, as perceived by the
managed object.
The default severity levels defined in the system, ordered from most severe to least
severe, are:
Table 1-2: Trap/Alarm Severit ies
Severity Description
Critical Indicates that a service affecting condition has occurred and an immediate
corrective action is required (e.g. when a managed object becomes completely
out of service and its capability must be restored).
Major Indicates that a service affecting condition has developed and an urgent
corrective action is required (e.g. when there is severe degradation in the
capability of the managed object and its full capability must be restored).
Minor Indicates the existence of a non-service affecting fault condition and that a
corrective action should be taken in order to prevent a more serious (for
example, service affecting) fault.
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
20/82
4 Traps and Alarms
Trap/Alarm Categories
The severity of the alarm affects also the following:
Unit Fault Status: The summarized severity of the unit's fault status. It
reflects the severity of the alarm with the highest severity that is ON at a
specific time. For a Base Station, this is the summarized severities of the NPU,
AUs, PIUs, PSUs and AVU.
System Fault Status: The summarized severity of the entire system fault
status.
4 Trap/Alarm Categories
The type of trap/alarm categorizes it into one of the following five basic categories
(as stated in ITU - CCITT Rec. X.733):
Warning Indicates the detection of a potential or impending service-affecting fault,before any significant effects have been felt. Action should be taken to further
diagnose (if necessary) and correct the problem in order to prevent it from
becoming a more serious service-affecting fault.
Info Indicates a non service-affecting event, which doesn't require any further
actions.
Table 1-3: Trap/Alarm Categor ies
Category Denoting String Description
Communications COMM Associated with the procedures and/or processes required
to convey information from one point to another.
Quality of service QoS Associated with degradation in the quality of a service.
Processing Error PROC Associated with software or processing fault.
Equipment EQUP Associated with an equipment fault.
Environmental ENVR Associated with a condition relating to an enclosure in
which the equipment resides.
Table 1-2: Trap/Alarm Severit ies
Severity Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
21/82
BreezeMAX Traps
Traps and Alarms 5
5 BreezeMAX Traps
BreezeMAX traps include the following trap groups:
General Traps on page 5
Chassis/Micro Base Station Related Traps on page 11
NPU/Micro Base Station Related Traps on page 15
ODU Related Traps on page 21
SU Related Traps on page 26
Software Download and BER Test Related Traps on page 29
File Download Related Traps on page 34
Service Related Traps on page 35
RADIUSs Related Traps on page 38
GPS Related Traps on page 42
Spectrum Analyzer Related Traps on page 49
IP CS Mode Configuration Related Traps on page 50
PF Server Related Traps on page 51
MIB II Traps on page 52
5.1 General Traps
5.1.1 rbResetOn Trap
Table 1-4: rbResetOn Trap Variables
Variable Description
Trap ID 1
Description The device/card is about to perform reset.
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
22/82
6 Traps and Alarms
BreezeMAX Traps
5.1.2 rbDiagnosticsHwFaultOn Trap
Trap Source BST/NPU/AU/SU
Trap Severity Info
Trap Category Equipment
Additional Info 1, 2 (see details in the following table)
Table 1-5: rbResetOn Trap Additional Info
No. Description
1 External Reset
2 Internal Fault Reset
Table 1-6: rbDiagnosticsHwFaultOn Trap Variables
Variable Description
Trap ID 2
Description The device/card has detected a hardware fault.
Trap Source BST/NPU/AU/SU
Trap Severity Major
Trap Category Equipment
Additional Info 3...8, 23...27 (see details in the following table)
Binding Parameters rbTrapLedStatus (not supported in current release)
Table 1-4: rbResetOn Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
23/82
BreezeMAX Traps
Traps and Alarms 7
5.1.3 rbDiagnosticsHwFaultOff Trap
Table 1-7: rbDiagnosticsHwFaultOn/Off Trap Additional Info
No. Description
3 SU HW fault. Manta's (ASIC) PLL is not locked for more than 5 msec.
4 SU HW fault. Manta's (ASIC) PLL is not locked in steady state.
5 SU HW fault. Host failed to download Manta's firmware (complete with CRC
errors, or handshake error).
6 SU HW fault. Radio's PLL is not locked after power up sequence.
7 SU HW fault. Radio's PLL is not locked in steady state.
8 SU, AU, NPU or BST HW fault. A Built In Test (BIT) has failed.
23 BST/AU HW fault. Output Tx Power exceeds PMAX+5dB for more than 5
minutes.
24 BST/AU HW fault. When a process to burn IDU table fails (CRC check on
finish fails, FTP session failed, no place in FFS).
25 BST/AU HW fault. IF synthesizer failed to lock on the frequency set on the
synthesizer.
26 BST/AU HW fault. BST/AU detected an error while downloading the ODU
table. The string includes also the byte number of the ODU table where the
error was detected.
27 BST/AU HW fault. Connection between BST/AU and ODU has been lost.
Table 1-8: rbDiagnosticsHwFaultOff Trap Variables
Variable Description
Trap ID 3
Description A previously detected hardware fault has been fixed.
Trap Source BST/NPU/AU/SU
Trap Severity Equipment
Trap Category Info
Additional Info 3...8, 23...27. For details see Additional Info in rbDiagnosticsHwFaultOn/Off
Trap Additional Info table above.
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
24/82
8 Traps and Alarms
BreezeMAX Traps
5.1.4 rbMonitorAccessOn Trap
5.1.5 rbMonitorAccessOff Trap
Table 1-9: rbMonitorAccessOn Trap Variables
Variable Description
Trap ID 4
Description The device is accessed via LCI (Monitor port) or Telnet.
Trap Source BST/NPU/SU
Trap Severity Info
Trap Category Equipment
Additional Info 140, 141. For details see the following table.
Binding Parameters rbTrapIpAddress (the IP Address of the station accessing the device)
Table 1-10: RbMonitorAccessOn/Off Trap Additional Info
No. Description
140 LCI (Monitor port) access has been detected.
141 Telnet access has been detected.
Table 1-11: rbMonitorAccessOff Trap Variables
Variable Description
Trap ID 5
Description LCI (Monitor port) or Telnet access to the device has been terminated.
Trap Source BST/NPU/SU
Trap Severity Info
Trap Category Equipment
Additional Info 140, 141. For details see rbMonitorAccessOn/Off Trap Additional Info table
above.
Binding Parameters rbTrapIpAddress (the IP Address of the station that accessed the device)
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
25/82
BreezeMAX Traps
Traps and Alarms 9
5.1.6 rbAuNetworkEntryStatus Trap
5.1.7 rbModeConflictOn Trap
Table 1-12: rbAuNetworkEntryStatus Trap Variables
Variable Description
Trap ID 6
Description BST/AU Network Entry status has been changed
Trap Source BST/AU
Trap Severity Info
Trap Category Communication
Additional Info 135...139. For details see the following table.
Table 1-13: rbAuNetworkEntryStatus Trap Additional Info
No. Description
135 BST/AU DHCP process failed
136 BST/AU configuration download failed
137 BST/AU set parameters failed
138 BST/AU firmware download failed
139 BST/AU is in service
Table 1-14: rbModeConfl ictOn Trap Variables
Variable Description
Trap ID 7
Description Conflict between configuration and units capabilities has been detected.
Trap Source AU/SU
Trap Severity Major
Trap Category Communication
Additional Info 144...149. For details see the following table.
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
26/82
10 Traps and Alarms
BreezeMAX Traps
5.1.8 rbModeConflictOff Trap
Table 1-15: rbAuModeConfli ctOn/Off Traps Additional Info
No. Description
144 Diversity Mode Mismatch: the AU does not support the configured diversity
mode (applicable only to old 2-channels AU).
145 Wrong Bandwidth: the AU/SU does not support the configured Bandwidth.
146 Wrong Duplex Mode - FDD. FDD mode configured, the AU does not support
FDD (aapplicable only to new High Power AU with SW version that does not
support FDD).
147 Wrong Duplex Mode - TDD. TDD mode configured, the AU does not support
TDD (applicable only to old 2-channels AU).
148 Wrong Cell Radius (Max): Configured Cell radius is above the maximum
supported by the AU (taking to consideration Frequency Band, Duplex Modeand Bandwidth. Applicable only to new High Power AU).
149 Wrong Cell radius (Min): Configured value is below the minimum supported by
the AU (applicable only to old 2-channels AU).
Table 1-16: rbModeConflictOff Trap Variables
Variable Description
Trap ID 8
Description Previously detected conflict between configuration and units capabilities has
been corrected.
Trap Source AU/SU
Trap Severity Major
Trap Category Communication
Additional Info 144. For details see rbAuModeConflictOn/Off Traps Additional Info table above.
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
27/82
BreezeMAX Traps
Traps and Alarms 11
5.1.9 rbOptimalRSSIConflict Trap
5.2 Chassis/Micro Base Station Related Traps
5.2.1 rbShelfCardExtractionOn Trap
5.2.2 rbShelfCardInsertionOn Trap
Table 1-17: rbOptimalRSSIConfl ict Trap Variables
Variable Description
Trap ID 9
Description Conflict between configured Optimal Rx RSSI value and units capabilities has
been detected.
Trap Source AU
Trap Severity Minor
Trap Category Communication
Binding Parameters rbAuOptimalRSSI (the actual value that will be used by the AU)
NOTE
In BST, Slot# will always be 1, and PSU# will always be 1.
Table 1-18: rbShelfCardExtractionOn Trap Variables
Variable Description
Trap ID 21
Description The card is being extracted from the chassis.
Trap Source NPU/AU/PIU/PSU/AVU
Trap Severity Info
Trap Category Equipment
Table 1-19: rbShelfCardInsertionOn Trap Variables
Variable Description
Trap ID 22
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
28/82
12 Traps and Alarms
BreezeMAX Traps
Description The card is being inserted into the chassis.
Trap Source NPU/AU/PIU/AU/AVU
Trap Severity Info
Trap Category Equipment
Table 1-19: rbShelfCardInsertionOn Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
29/82
BreezeMAX Traps
Traps and Alarms 13
5.2.3 rbShelfPeripheralEquipmentFaultOn Trap
5.2.4 rbShelfPeripheralEquipmentFaultOff Trap
Table 1-20: rbShelfPeripheralEquipmentFaultOn Trap Variables
Variable Description
Trap ID 23
Description A fault has been detected in a peripheral unit or a BST component.
Trap Source BST/PIU/PSU/AVU/AVU-FAN
Trap Severity Minor
Trap Category Equipment
Additional Info 53...55
Table 1-21: rbShelfPeripheralEquipmentFaultOn Trap Additional Info
No. Description
53 A fault has been detected in a PSU, or BST has detected a power supply
failure.
54 A fault has been detected in a PIU (not applicable to BST).
55 A fault has been detected in the AVU, or the BST has detected a problem in at
least one of its fans.
Table 1-22: rbShelfPeripheralEquipmentFaultOff Trap
Variable Description
Trap ID 24
Description A fault in a peripheral unit has been corrected.
Trap Source BST/PIU/PSU/AVU/AVU-FAN
Trap Severity Info
Trap Category Equipment
Additional Info 53...55. See details in the following table.
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
30/82
14 Traps and Alarms
BreezeMAX Traps
5.2.5 rbShelfEnvParamFaultOn Trap
Table 1-23: rbShelfPeripheralEquipmentFaultOff Trap Addit ional Info
No. Description
53 NPU/BST has detected that the faulty PSU/power supply has become fully
operational.
54 NPU has detected that the faulty PIU has become fully operational.
55 NPU/BST has detected that the faulty AVU/fan has become fully operational
Table 1-24: rbShelfEnvParamFaultOn Trap Variables
Variable Description
Trap ID 25
Description A fault has been detected in a chassis environmental parameter.
Trap Source BST/NPU
Trap Severity Info
Trap Category Equipment
Additional Info 73...76. For details see the following table.
Table 1-25: rbShelfEnvParamFaultOn/Off Trap Additional Info
No. Description
73 A fault has been detected in the dry contacts of NPU/BST.
74 An NPU/BST temperature fault has been detected.
75 An AU-IDU temperature fault has been detected.
76 An AU-ODU temperature fault has been detected.
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
31/82
BreezeMAX Traps
Traps and Alarms 15
5.2.6 rbShelfEnvParamFaultOff Trap
5.3 NPU/Micro Base Station Related Traps
5.3.1 rbConfigurationChanged Trap
Table 1-26: rbShelfEnvParamFaultOff Trap
Variable Description
Trap ID 26
Description A previously detected fault in a chassis environmental parameter has been
fixed.
Trap Source BST/NPU
Trap Severity Info
Trap Category Equipment
Additional Info 73...76. For details see rbShelfEnvParamFaultOn/Off Trap Additional Info table
above.
Table 1-27: rbConfigurationChanged Trap Variables
Variable Description
Trap ID 41
Description A configuration change has been detected.
Trap Source See list in
Trap Severity Info
Trap Category Equipment
Additional Info 30...33. For details see the following table.
Table 1-28: rbConfigurationChanged Trap Additional Info
No. Description
30 Configuration changed - element added event.
31 Configuration changed - element deleted event.
32 Configuration changed - element modified event.
33 A Management Port parameter has been changed.
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
32/82
16 Traps and Alarms
BreezeMAX Traps
5.3.2 rbParameterSetFailure Trap
Table 1-29: rbParameterSetFailure Trap Variables
Variable Description
Trap ID 42
Description An error in configuration change has been detected.
Trap Source BST/NPU/AU/SU
Trap Severity Info
Trap Category Equipment
Binding Parameters rbTrapSetFailureReason. SeeTable 1-30below.
http://-/?-http://-/?-8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
33/82
BreezeMAX Traps
Traps and Alarms 17
Table 1-30: rbTrapSetFailureReason
No. Description
1 General Error
2 Failed to update parameters CRC
3 Set defaults to unknown type (internal error)
4 Failed to set defaults (internal error)
5 Log prefix is too long
6 Failed to set Log Prefix (internal error)
7 Cell Radius is invalid
8 Failed to set Cell Radius
9 Failed to set Base Station ID (internal error)
10 Failed to set Base Station Mask (internal error)
11 Failed to set ARQ mode (internal error)
12 Failed to set Band (internal error)
13 Tx Frequency is out of calculated limited range
14 Tx frequency is invalid
15 Tx frequency is out of maximum permitted range
16 Tx Frequency set failed (internal error)
17 Tx Power value is invalid
18 Set Tx Power Failed (internal error)
19 UL Basic rate is invalid
20 Failed to set Uplink Basic Rate (internal error)
21 DL Basic rate is invalid
22 Failed to set Downlink Basic Rate (internal error)
23 It is forbidden to set SU rate while Multirate is enabled
24 Invalid Downlink rate
25 Invalid Uplink rate
26 Invalid Optimal RSSI
27 Set Optimal RSSI failed (internal error)
28 BER Test data size is less than minimum allowed
29 BER Test data size is higher than the maximum allowed
30 BER Test is already running
31 Invalid BER Test Rate
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
34/82
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
35/82
BreezeMAX Traps
Traps and Alarms 19
5.3.4 rbMbstCPEQuantityExceed Trap
5.3.5 rbLicenseFileLoadStatus Trap
Table 1-33: rbMbstCPEQuantityExceed Trap Variables
Variable Description
Trap ID 51
Description Allowed quantity of CPEs has been exceeded.
Trap Source BST
Trap Severity Info
Trap Category PROC
Binding Parameters rbSuMacAddr (the MAC Address of rejected SU)
Table 1-34: rbLicenseFileLoadStatus Trap Variables
Variable Description
Trap ID 52
Description License file loading process status.
Trap Source BST/NPU
Trap Severity Info
Trap Category PROC
Additional Info 187...195. For details see the following table.
Table 1-35: rbLicenseFileLoadStatus Trap Additional Info
No. Description
187 License file loaded to wrong device (MAC address conflict).
188 MD5 format is not valid.
189 License file syntax error or empty file.
190 Wrong number of CPEs in Micro Base station Number of Supported CPEs
license file.
191 License file already exists in database.
192 No MD5 match
193 Illegal license count or value (less than 0)
194 Illegal BW ID
195 Too many licenses (more than 5) in file
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
36/82
20 Traps and Alarms
BreezeMAX Traps
5.3.6 rbMbstLicenseChanged Trap
5.3.7 rbCPELicenseAssigned Trap
5.3.8 rbBackupFileSwitchingModeMismatch Trap
Table 1-36: rbMbstL icenseChanged Trap Variables
Variable Description
Trap ID 53
Description Micro Base Stations license has been changed
Trap Source BST
Trap Severity Info
Trap Category PROC
Binding Parameters IrbAuNumberOfRegisteredSUs (the number of registered SUs) and
rbBstLicenseValue (total number of CPE licenses)
Table 1-37: rbCPELicenseAssigned Trap Variables
Variable Description
Trap ID 54
Description CPE license has been assigned
Trap Source BST/NPU
Trap Severity Info
Trap Category PROC
Binding Parameters rbLicenseCount (available Lll icenses in the CPEs License Bank),
rbLicenseTotal (total number of licenses) and rbSuMacAddr (MAC address of
the last SU assisgned with a license)
Table 1-38: rbBackupFileSwitchingModeMismatch Trap Variables
Variable Description
Trap ID 55
Description Mismatc in Switching Mode between device and loaded backup file
Trap Source NPU
Trap Severity Info
Trap Category Equipment
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
37/82
BreezeMAX Traps
Traps and Alarms 21
5.3.9 rbLastPmTmFileName Trap
5.4 ODU Related Traps
The ODU related traps are generated by the AU/BST. The ODU related traps
include the rbChannelId and rbOduConfigId as binding parameters, identifying
the Channel associated with the ODU and the ODU.
5.4.1 rbOduCommErrorOn Trap
5.4.2 rbOduCommErrorOff Trap
Table 1-39: rbLastPmTmFileName Trap Variables
Variable Description
Trap ID 56
Description A new PMTM file has been generated
Trap Source NPU
Trap Severity Info
Trap Category Equipment
Binding Parameters rbBSPmTmLastFileName
Table 1-40: rbOduCommErrorOn Trap Variables
Variable Description
Trap ID 63
Description An error has been detected in the communication with the ODU associated
with the specified Channel ID.
Trap Source BST/AU
Trap Severity Minor
Trap Category Communication
Binding Parameters rbChannelId, rbOduConfigId
Table 1-41: rbOduCommErrorOff Trap Variables
Variable Description
Trap ID 64
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
38/82
22 Traps and Alarms
BreezeMAX Traps
Description A previously detected error in the communication with the ODU associated withthe specified Channel ID has been fixed.
Trap Source BST/AU
Trap Severity Info
Trap Category Communication
Binding Parameters rbChannelId, rbOduConfigId
Table 1-41: rbOduCommErrorOff Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
39/82
BreezeMAX Traps
Traps and Alarms 23
5.4.3 rbOduBandMissmatchOn Trap
5.4.4 rbOduBandMissmatchOff Trap
Table 1-42: rbOduBandMissmatchOn Trap Variables
Variable Description
Trap ID 65
Description A mismatch was detected between the Configured Frequency Band and actual
band supported by the HW of the ODU associated with the specified Channel
ID.
Trap Source BST/AU
Trap Severity Major
Trap Category Communication
Binding Parameters rbChannelId, rbOduConfigId
Table 1-43: rbOduBandMissmatchOff Trap Variables
Variable Description
Trap ID 66
Description A previously detected mismatch between the Configured Frequency Band and
actual band supported by the HW of the ODU associated with the specified
Channel ID was fixed.
Trap Source BST/AU
Trap Severity Info
Trap Category Communication
Binding Parameters rbChannelId, rbOduConfigId
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
40/82
24 Traps and Alarms
BreezeMAX Traps
5.4.5 rbOduPowerMissmatch Trap
5.4.6 rbOduFailureOn Trap
Table 1-44: rbOduPowerMissmatch Trap Variables
Variable Description
Trap ID 67
Description Configured Tx Power of the ODU associated with the specified Channel ID is
higher than the actual Maximum Tx Power of the ODU.
Trap Source BST/AU
Trap Severity Info
Trap Category Communication
Binding Parameters rbChannelId, rbOduConfigId
Table 1-45: rbOduFailureOn Trap Variables
Variable Description
Trap ID 68
Description ODU unit failure has been detected.
Trap Source BST/AU
Trap Severity Major
Trap Category Communication
Additional Info 225-228. For details seeTable 1-46below.
Binding Parameters rbChannelId, rbOduConfigId, rbOduStatusMask (for details on ODU Status
Mask refer toTable 1-47below)
Table 1-46: rbOduFailureOn Trap Additional Info
No. Description
225 ODU was shut down as a result of over current.
226 ODU was shut down as a result of unlocked synthesizer
227 ODU was shut down as a result of a too high reflected power
228 ODU was shut down as a result of over heating
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
41/82
BreezeMAX Traps
Traps and Alarms 25
The Status Mask is comprised of 8 hexadecimal digits representing 32 bits. The
table below shows the meaning of each bit and the Status Mask when the
applicable bit is set to 1:
Table 1-47: ODU Status Mask Details
Bit # Status Mask Problem Description
None 00-00-00-00 No problem
1 00-00-00-01 "ODU temperature is too high"
2 00-00-00-02 "ASK attenuator is off"
3 00-00-00-04 "RF Synth. is not locked"
4 00-00-00-08 "Reverse power alarm is on"
5 00-00-00-10 "REF V. tune alarm is on"
6 00-00-00-20 "RF RX DCA is not 12dB"
7 00-00-00-40 "TX IF DCA reached it's limits"
8 00-00-00-80 "PD power VVA is out of limits"
9 00-00-01-00 "PA#1 current is out of limits"
10 00-00-02-00 "HPA current is out of limits"
11 00-00-04-00 "RF VVA is out of limits"
12 00-00-08-00 "ADC source is digital"
13 00-00-10-00 "REF synthesizer is not locked"
14 00-00-20-00 "TI Gain is off"
15 00-00-40-00 "BW select is 10MHz"
16 00-00-80-00 "PA#2 current is out of limits"
17 00-01-00-00 "TX RF DCA value mismatch"
18 00-02-00-00 "HPA does not exist"
19 00-04-00-00 "LNA is off"
20 00-08-00-00 "Over Current alarm is on"
21 00-10-00-00 "REF_V_TUNE is out of range"
22 00-20-00-00 "PA1 max iterations exceeded"
23 00-40-00-00 "PA2 max iterations exceeded"
24 00-80-00-00 "HPA max iterations exceeded"
25 01-00-00-00 "VVA max iterations exceeded"
26 02-00-00-00 "PD VVA max iterations exceeded"
27-32 04-00-00-00 to 80-00-00-00 reserved for future use
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
42/82
26 Traps and Alarms
BreezeMAX Traps
5.4.7 rbOduFailureOff Trap
5.5 SU Related Traps
5.5.1 rbSuMaxTxPowerReached Trap
5.5.2 rbSuMinTxPowerReached Trap
Table 1-48: rbOduFailureOff Trap Variables
Variable Description
Trap ID 69
Description A previously detected ODU failure was fixed.
Trap Source BST/AU
Trap Severity Info
Trap Category Communication
Binding Parameters rbChannelId, rbOduConfigId
Table 1-49: rbSuMaxTxPowerReached Trap Variables
Variable Description
Trap ID 81
Description The SU has reached the maximum allowed output power.
Trap Source SU
Trap Severity Info
Trap Category PROC
Binding Parameters rbSuTxPower (the actual Tx Power)
Table 1-50: rbSuMinTxPowerReached Trap Variables
Variable Description
Trap ID 82
Description The SU has reached the minimum allowed output power.
Trap Source SU
Trap Severity Info
Trap Category PROC
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
43/82
BreezeMAX Traps
Traps and Alarms 27
5.5.3 rbSuNetworkEntryStatus Trap
5.5.4 rbSuLicense Trap
Binding Parameters rbSuTxPower (the actual Tx Power)
Table 1-51: rbSuNetworkEntryStatus Trap Variables
Variable Description
Trap ID 83
Description SU's network entry status has been changed.
Trap Source SU
Trap Severity Info
Trap Category PROC
Additional Info 132...134. For details see the following table.
Table 1-52: rbSuNetworkEntryStatus Trap Add itional Info
No. Description
132 Authentication process failed
133 Registration process failed
134 Registration process completed successfully
Table 1-53: rrbSuLicense Trap Variables
Variable Description
Trap ID 84
Description License Grace Period warning.
Trap Source SU
Trap Severity Info
Trap Category PROC
Additional Info 182...186. For details see the following table.
Binding Parameters rbLicenseId (Type of License). The currently supported value for rbLicenseId is
bandwidth (1).
Table 1-50: rbSuMinTxPowerReached Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
44/82
28 Traps and Alarms
BreezeMAX Traps
Table 1-54: rbSuLicense Trap Addit ional Info
No. Description
182 Temporary Grace Period started.
183 Temporary Grace Period expired.
184 Grace Period started.
185 Grace Period expired.
186 Grace Period will expire in 3 days.
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
45/82
BreezeMAX Traps
Traps and Alarms 29
5.5.5 rbSuDuplicateName Trap
5.6 Software Download and BER Test Related Traps
5.6.1 rbSwDownloadStart Trap
5.6.2 rbSwDownloadEnd Trap
Table 1-55: 5.5.4rbSuDupli cateName Trap Variables
Variable Description
Trap ID 85
Description The SU Name is already in use by another SU. Services to the SU will be
denied until another, unique name is configured for the SU. The SU's name in
the database is changed temporarily to SU@ until a new name
is configured.
Trap Source SU
Trap Severity Major
Trap Category PROC
Binding Parameters rbSuMacAddr (the MAC Address of the other SU with the same name),
rbSuSysName (the duplicate name) and rbSuSysName (the new temporary
name).
Table 1-56: rbSwDownloadStart Trap Variables
Variable Description
Trap ID 101
Description SW download process has started.
Trap Source BST/NPU/AU/SU
Trap Severity Info
Trap Category PROC
Table 1-57: rbSwDownloadEnd Trap Variables
Variable Description
Trap ID 102
Description SW download process has been finished.
Trap Source BST/NPU/AU/SU
Trap Severity Info
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
46/82
30 Traps and Alarms
BreezeMAX Traps
5.6.3 rbSwDownloadError Trap
Trap Category PROC
Table 1-58: rbSwDownloadError Trap Variables
Variable Description
Trap ID 103
Description An error has been detected in the SW download process.
Trap Source BST/NPU/AU/SU
Trap Severity Minor
Trap Category PROC
Additional Info 100...103, 150..181. See details in the following table.
NOTE
Additional Info 150181 details reasons for AU/SU SW download failures.
Table 1-59: rbSwDownloadError Trap Additional Info
No. Description
100 Unsupported Software version has been detected. This trap is generated by a
BST/NPU when there is no compatibility between versions (BST/NPU, AU or
SU). It is generated by AU and SU when there is no compatibility with
corresponding SU or AU versions.
101 The requested SW version is not available at BST/NPU site. This trap is
generated only by BST/NPU.
102 SW download process failed.
103 No space available in disk. There are already 3 SW versions in BST/NPU forAU/SU, and another version is being downloaded.
150 Download is aborted by an external event.
151 Header's "HW Version" is not compatible with the real unit's HW
152 Header's "HW Config" is not compatible with the real unit's HW
153 Failure to create a new file on Flash
154 Failure to open file on Flash
155 Failure to get file statistics (size..)
Table 1-57: rbSwDownloadEnd Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
47/82
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
48/82
32 Traps and Alarms
BreezeMAX Traps
5.6.4 rbSwSwitchFailed Trap
5.6.5 rbSwSwitchSucceed Trap
5.6.6 rbBERTestFinished Trap
* Not applicable for current release
Table 1-60: rbSwSwitchFailed Trap Variables
Variable Description
Trap ID 104
Description Software switch-over failed
Trap Source BST/NPU/AU/SU
Trap Severity Minor
Trap Category PROC
Additional Info 104, 105. See details in the following table
Table 1-61: rbSwSwitchFailed Trap Addi tional Info
No. Description
104 Run from shadow action
105 Set as Main action
Table 1-62: rbSwSwitchSucceed Trap Variables
Variable Description
Trap ID 105
Description Software switch-over succeeded
Trap Source BST/NPU/AU/SU
Trap Severity Info
Trap Category PROC
Additional Info 104, 105. See details in the table above
Table 1-63: rbBERTestFin ished Trap Variables
Variable Description
Trap ID 106
Description BER Test finished
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
49/82
BreezeMAX Traps
Traps and Alarms 33
Trap Source AU
Trap Severity Info
Trap Category PROC
Additional Info 230, 231. See details in the following table.
Binding Parameters rbSuMacAddr and rbSuSysName
Table 1-64: rbERTestFinished Trap Additional Info
No. Description
230 Test stopped
231 Test Aborted
Table 1-63: rbBERTestFin ished Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
50/82
34 Traps and Alarms
BreezeMAX Traps
5.6.7 rbBERTestStarted Trap
* Not applicable for current release
5.6.8 rbSwFileConflict Trap
5.7 File Download Related Traps
5.7.1 rbXMLDownloadResult Trap
* Not applicable to current release.
Table 1-65: rbBERTestStarted Trap Variables
Variable Description
Trap ID 107
Description BER Test has started
Trap Source AU
Trap Severity Info
Trap Category PROC
Binding Parameters rbSuMacAddr and rbSuSysName
Table 1-66: rbSwFileConfl ict Trap Variables
Variable Description
Trap ID 108
Description The HW of the AU/SU does not support the type (Advanced Si/Standard) of the
SW File.
Trap Source AU/SU
Trap Severity Minor
Trap Category PROC
Table 1-67: rbXMLDownloadResult Trap Variables
Variable Description
Trap ID 109
Description XML file download status
Trap Source BST/NPU
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
51/82
BreezeMAX Traps
Traps and Alarms 35
5.7.2 rbFreqBandDownloadResult Trap
5.8 Service Related Traps
5.8.1 rbServiceDown Trap
Trap Severity Info
Trap Category PROC
Additional Info 220..224. See details in the following table.
Table 1-68: r rbXMLDownloadResult and rbFreqBandDownloadResult Traps Add itional Info
No. Description
219 Wrong RFU (Frequency Bands) File version
220 File download started.
221 File download completed
222 File MD5 (signature) failure
223 File parsing failure
224 File download failure
Table 1-69: rbFreqBandDownloadResult Trap Variables
Variable Description
Trap ID 110
Description Frequency Bands file download status
Trap Source BST/NPU
Trap Severity Info
Trap Category PROC
Additional Info 217..222, 224. See details in rbXMLDownloadResult and
rbFreqBandDownloadResult Traps Additional Info table above.
Table 1-70: rbServ iceDown TrapVariables
Variable Description
Trap ID 111
Description The Service is down
Table 1-67: rbXMLDownloadResult Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
52/82
36 Traps and Alarms
BreezeMAX Traps
5.8.2 rbServiceUp Trap
5.8.3 rbServiceChanged Trap
Trap Source BST/NPU
Trap Severity Major
Trap Category QoS
Binding Parameters rbServiceIdx, rbSubscriberIdx, rbServiceName, rbSubscriberID, rbSuMacAddr.
Table 1-71: rbServiceUp Trap Variables
Variable Description
Trap ID 112
Description The service has become operational
Trap Source BST/NPU
Trap Severity Info
Trap Category QoS
Binding Parameters rbServiceIdx, rbSubscriberIdx, rbServiceName, rbSubscriberID, rbSuMacAddr.
Table 1-72: rbServi ceChanged Trap Variables
Variable Description
Trap ID 113
Description The Service properties have been modified
Trap Source BST/NPU
Trap Severity Info
Trap Category QoS
Additional Info 119...122. See details in the following table.
Binding Parameters rbServiceIdx, rbSubscriberIdx, rbServiceName, rbSubscriberID.
Table 1-73: rbServiceChanged Trap Additional Info
No. Description
119 Service Admin Status has been changed
120 Service SU MAC Address has been changed
Table 1-70: rbServ iceDown TrapVariables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
53/82
BreezeMAX Traps
Traps and Alarms 37
5.8.4 rbServiceGeneralError Trap
121 Service VLAN List has been changed
122 Service Profile has been changed (implies that another Service Profile has
been set)
Table 1-74: rbServiceGeneralError Trap Variables
Variable Description
Trap ID 114
Description A Service error has been detected
Trap Source BST/NPU
Trap Severity Minor
Trap Category QoS
Additional Info 111...118. See details in the following table.
Binding Parameters rbServiceIdx, rbSubscriberIdx, rbServiceName, rbSubscriberID.
Table 1-75: rbServiceGeneralError Trap Additional Info
No. Description
111 The maximum allowed number of Subscribers has been reached
112 The maximum allowed number of Service configurations has been reached
113 The maximum allowed number of Service Profile configurations has been
reached
114 The maximum allowed number of Forwarding Rules configurations has been
reached
115 The maximum allowed number of Policy Rules configurations has been
reached
116 The maximum allowed number of QoS Profiles configurations has been
reached
117 The maximum allowed number of calls has been reached
118 There is no available bandwidth to allocate to a new VoIP call
Table 1-73: rbServiceChanged Trap Additional Info
No. Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
54/82
38 Traps and Alarms
BreezeMAX Traps
5.8.5 rbNetworkingError Trap
5.9 RADIUSs Related Traps
5.9.1 rbSwitchedAuthenticationServer Trap
5.9.2 rbSwitchedAccountingServer Trap
Table 1-76: rbNetworkingError Trap Variables
Variable Description
Trap ID 115
Description Networking error has been detected. Services to the SU are denied until the SU
is reset from the wireless link side by the NPU/BST.
Trap Source SU
Trap Severity Info
Trap Category PROC
Additional Info 10: Loop was detected on SU Ethernet port.
Table 1-77: rbSwitchedAuthenticationServer Trap Variables
Variable Description
Trap ID 117
Description RADIUS Client has switched to another Authentication Server Trap Source BST/NPU
Trap Severity Info
Trap Category Comm
Table 1-78: rbSwitchedAccountingServer Trap Variables
Variable Description
Trap ID 118
Description RADIUS Client has switched to another Accounting Server
Trap Source BST/NPU
Trap Severity Info
Trap Category Comm
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
55/82
BreezeMAX Traps
Traps and Alarms 39
5.9.3 rbServiceEstablishmentFailure Trap
Table 1-79: rbServiceEstablishmentFailure Trap Variables
Variable Description
Trap ID 119
Description Service establishment failure
Trap Source BST/NPU
Trap Severity Minor
Trap Category QoS
Additional Info 200..210, 214. See details in the following table.
Binding Parameters rbServiceIdx and rbServiceName (created from User Name (SU MAC) and
Service index)
Table 1-80: rbServiceEstablishmentFailure Trap Additional Info
No. Description
200 Service Profile does not exist
201 Too many VLAN IDs defined for the service
202 Too many VLAN IDs are defined for one SU
203 Wrong VLAN ID (0 to 4094 expected)
204 Definitions mismatch between Transparent Mode and VPL ID
205 VLANs mismatch: Can't allocate for the same SU services with and without
VLANs
206 Service Type and VLAN mismatch: Can't create 2 services with either the same
type of service, or L2 and Voice services, with the same VLAN ID
207 Only one VLAN permitted when VLAN classification mode is On
208 Access VLAN mismatch: Access VLAN is permitted only with Hybrid Mode Off
and an empty VLAN list, or for Hybrid Mode On with a VLAN list
209 Duplicate VLAN: Access VLAN can not be equal to any VLAN in the SU VLAN
list
210 Too many Access VLANs: Only one Access VLAN allowed per SU
211 Client Authentication timeout: No connection between NPU and Authentication
Server during authentication or re-authentication
212 User Accounting Server start time out
213 User Accounting Server stop time out
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
56/82
40 Traps and Alarms
BreezeMAX Traps
5.9.4 rbUserAuthenticationTimeout Trap
5.9.5 rbUserAuthenticationReject Trap
5.9.6 rbAuthenticationServerKeepAliveTimeoutOn Trap
214 Services Table is full
Table 1-81: rbUserAuthenticationTimeout Trap Variables
Variable Description
Trap ID 120
Description User authentication timeout
Trap Source BST/NPU
Trap Severity Info
Trap Category Comm
Additional Info 211..213. See details in the table above.
Binding Parameters rbSuMacAddr
Table 1-82: rbUserAuthenticationReject Trap Variables
Variable Description
Trap ID 121
Description User authentication rejected
Trap Source BST/NPU
Trap Severity Info
Trap Category Comm
Binding Parameters rbSuMacAddr
Table 1-83: rbAuthenticationServerKeepAliveTimeoutOn Trap Variables
Variable Description
Trap ID 122
Description Authentication Server Keep Alive Timeout has been detected
Trap Source BST/NPU
Trap Severity Major
Table 1-80: rbServiceEstablishmentFailure Trap Additional Info
No. Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
57/82
BreezeMAX Traps
Traps and Alarms 41
5.9.7 rbAuthenticationServerKeepAliveTimeoutOff Trap
5.9.8 rbAccountingServerKeepAliveTimeoutOn Trap
5.9.9 rbAccountingServerKeepAliveTimeoutOff Trap
Trap Category Equipment
Binding Parameters rbRadiusAuthServerAddress
Table 1-84: rbAuthenticationServerKeepAliveTimeoutOff Trap Variables
Variable Description
Trap ID 123
Description Previously detected Authentication Server Keep Alive Timeout terminated,
Trap Source BST/NPU
Trap Severity Info
Trap Category Equipment
Binding Parameters rbRadiusAuthServerAddress
Table 1-85: rbAccountingServerKeepAliveTimeoutOn Trap Variables
Variable Description
Trap ID 124
Description Accounting Server Keep Alive Timeout has been detected
Trap Source BST/NPU
Trap Severity Major
Trap Category Equipment
Binding Parameters rbRadiusAcctServerAddress
Table 1-86: rbAccount ingServerKeepAliveTimeoutOff Trap Variables
Variable Description
Trap ID 125
Description Previously detected Accounting Server Keep Alive Timeout terminated,
Trap Source BST/NPU
Trap Severity Info
Table 1-83: rbAuthenticationServerKeepAliveTimeoutOn Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
58/82
42 Traps and Alarms
BreezeMAX Traps
5.10 GPS Related Traps
5.10.1 rbExternal1PPSFailureOn Trap
5.10.2 rbExternal1PPSFailureOff Trap
5.10.3 rbInternal1PPSFailureOn Trap
Trap Category Equipment
Binding Parameters rbRadiusAcctServerAddress
Table 1-87: rbExternal1PPSFailureOn Trap Variables
Variable Description
Trap ID 134
Description External 1PPS failure has been detected. Applicable only if external 1PPS
clock is enabled .
Trap Source BST/NPU
Trap Severity Major
Trap Category Equipment
Table 1-88: rbExternal1PPSFailu reOff Trap Variables
Variable Description
Trap ID 135
Description Previously detected External 1PPS failure has been terminated.
Trap Source BST/NPU
Trap Severity Info
Trap Category Equipment
Table 1-89: rbInternal1PPSFailureOn Trap Variables
Variable Description
Trap ID 136
Description Internal 1PPS failure has been detected. Applicable only if external 1PPS clock
is disabled .
Table 1-86: rbAccount ingServerKeepAliveTimeoutOff Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
59/82
BreezeMAX Traps
Traps and Alarms 43
5.10.4 rbInternal1PPSFailureOff Trap
5.10.5 rbExternal16MHzFailureOn Trap
5.10.6 rbExternal16MHzFailureOff Trap
Trap Source BST/NPU
Trap Severity Major
Trap Category Equipment
Table 1-90: rbInternal1PPSFailureOff Trap Variables
Variable Description
Trap ID 137
Description Previously detected Internal 1PPS failure has been terminated.
Trap Source BST/NPU
Trap Severity Info
Trap Category Equipment
Table 1-91: rbExternal16MHzFailu reOn Trap Variables
Variable Description
Trap ID 138
Description External 16MHz failure has been detected. Applicable only if external 16MHz
clock is enabled .
Trap Source BST/NPU
Trap Severity Major
Trap Category Equipment
Table 1-92: rbExternal16MHzFailureOff Trap Variables
Variable Description
Trap ID 139
Description Previously detected External 16MHz failure has been terminated.
Trap Source BST/NPU
Trap Severity Info
Trap Category Equipment
Table 1-89: rbInternal1PPSFailureOn Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
60/82
44 Traps and Alarms
BreezeMAX Traps
5.10.7 rbInternal16MHzFailureOn Trap
5.10.8 rbInternal16MHzFailureOff Trap
5.10.9 rbGPSComFailureOn Trap
Table 1-93: rb Internal16MHzFailureOn Trap Variables
Variable Description
Trap ID 140
Description Internal 16MHz failure has been detected. Applicable only if external 16MHz
clock is disabled .
Trap Source BST/NPU
Trap Severity Major
Trap Category Equipment
Table 1-94: rbInternal16MHzFailureOff Trap Variables
Variable Description
Trap ID 141
Description Previously detected Internal 16MHz failure has been terminated.
Trap Source BST/NPU
Trap Severity Info
Trap Category Equipment
Table 1-95: rbGPSComFailu reOn Trap Variables
Variable Description
Trap ID 142
Description GPS communication failure has been detected. Applicable only if GPS type is
Trimble.
Trap Source BST/NPU
Trap Severity Major
Trap Category Equipment
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
61/82
BreezeMAX Traps
Traps and Alarms 45
5.10.10 rbGPSComFailureOff Trap
5.10.11 rbGPSHealthyFailureOn Trap
5.10.12 rbGPSHealthyFailureOff Trap
Table 1-96: rbGPSComFailu reOff Trap Variables
Variable Description
Trap ID 143
Description Previously detected GPS communication failure has been terminated.
Trap Source BST/NPU
Trap Severity Info
Trap Category Equipment
Table 1-97: rbGPSHealthyFailureOn Trap Variables
Variable Description
Trap ID 144
Description GPS failure has been detected. Applicable only if GPS type is Trimble.
Trap Source BST/NPU
Trap Severity Major
Trap Category Equipment
Table 1-98: rbGPSHealthyFailureOff Trap Variables
Variable Description
Trap ID 145
Description Previously detected GPS failure has been terminated.
Trap Source BST/NPU
Trap Severity Info
Trap Category Equipment
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
62/82
46 Traps and Alarms
BreezeMAX Traps
5.10.13 rbMin4SatSyncFailureOn Trap
5.10.14 rbMin4SatSyncFailureOff Trap
5.10.15 rbAUExternal1PPSFailureOn Trap
Table 1-99: rbMin4SatSyncFailureOn Trap Variables
Variable Description
Trap ID 146
Description Less than four satellites are received by the GPS. Applicable only if GPS type
is Trimble.
Trap Source BST/NPU
Trap Severity Major
Trap Category Equipment
Table 1-100: rbMin4SatSyncFailureOff Trap Variables
Variable Description
Trap ID 147
Description Previously detected failure status where less than 4 satellites are received by
the GPS has been terminated.
Trap Source BST/NPU
Trap Severity Info
Trap Category Equipment
Table 1-101: rbAUExternal1PPSFailureOn Trap Variables
Variable Description
Trap ID 148
Description External 1PPS failure has been detected by the AU, indicating a failure in
selected 1PPS clock arriving from the NPU.
Trap Source AU
Trap Severity Major
Trap Category Equipment
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
63/82
BreezeMAX Traps
Traps and Alarms 47
5.10.16 rbAUExternal1PPSFailureOff Trap
5.10.17 rbAUHoldOverEnteredOn Trap
5.10.18 rbAUHoldOverEnteredOff Trap
Table 1-102: rbAUExternal1PPSFailureOff Trap Variables
Variable Description
Trap ID 149
Description Previously detected External 1PPS (from NPU to AU) failure has been
terminated.
Trap Source AU
Trap Severity Info
Trap Category Equipment
Table 1-103: rbAUHoldOverEnteredOn Trap Variables
Variable Description
Trap ID 150
Description AU has entered Hold Over status.
Trap Source AU
Trap Severity Major
Trap Category Equipment
Table 1-104: rbAUHoldOverEnteredOff Trap Variables
Variable Description
Trap ID 151
Description AU has exitted Hold Over.
Trap Source AU
Trap Severity Info
Trap Category Equipment
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
64/82
48 Traps and Alarms
BreezeMAX Traps
5.10.19 rbAUHoldOverTimeoutPassedOn Trap
5.10.20 rbAUHoldOverTimeoutPassedOff Trap
5.10.21 rbAUHoldOverTxStoppedOn Trap
Table 1-105: rbAUHoldOverTimeoutPassedOn Trap Variables
Variable Description
Trap ID 152
Description Hold Over Timeout has passed.
Trap Source AU
Trap Severity Major
Trap Category Equipment
Table 1-106: rbAUHoldOverTimeoutPassedOff Trap Variables
Variable Description
Trap ID 153
Description Hold Over Timeout passed status has been terminated.
Trap Source AU
Trap Severity Info
Trap Category Equipment
Table 1-107: rbAUHoldOverTxStoppedOn Trap Variables
Variable Description
Trap ID 154
Description Hold Over Timeout has passed and Tx was stopped.
Trap Source AU
Trap Severity Major
Trap Category Equipment
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
65/82
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
66/82
50 Traps and Alarms
BreezeMAX Traps
5.12 IP CS Mode Configuration Related Traps
5.12.1 rbIPCSModeConfigurationError Trap
Additional Info 229..232. See details in the following table.
Table 1-111: rbAUSpecAnalyzerTestStatus Trap Addit ional Info
No. Description
Test Started
230 Test stopped
231 Test Aborted
Test Not Ready
Table 1-112: rbIPCSModeConfigurationError Trap Variables
Variable Description
Trap ID 163
Description IP CS Mode configuration error
Trap Source NPU
Trap Severity Info
Trap Category Equipment
Additional Info 235..241. See details in the following table.
Table 1-113: rbIPCSModeConfigurationError Trap Additional Info
No. Description
235 Invalid Filter ID in Accept message from AAA server
236 Frame IP for VoIP service in Accept message from AAA server is invalid
237 Service Profile with VLAN Transparency Mode is invalid
238 Service Profile with Priority Marking is invalid
239 Service Profile with VPL ID is invalid
Table 1-110: rbAUSpecAnalyzerTestStatus Trap Variables
Variable Description
8/11/2019 BreezeMAX TDD Ver.4.5 Traps & Alarms_080513
67/82
BreezeMAX Traps
Traps and Alarms 51
5.13 PF Server Related Traps
5.13.1 rbPFSereverKeepAliveTimeoutOn Trap
5.13.2 rbPFSereverKeepAliveTimeoutOff Trap
240 Service Profile with Maximum Number of Calls is invalid
241 Same Frame IP With Same VPL ID is invalid
Table 1-114: rbPFSereverKeepAliveTimeoutOn Trap Variables
Variable Description
Trap ID 170
Description PF Server Keep Alive Timeout has been detected
Trap Source BST/NPU
Trap Severity Major
Trap Category Equipment
Binding Parameters rbPMPFServerIpAddress
Table 1-115: rbPFSereverKeepAl iveTimeoutOff Trap Variables
Variable Description
Trap ID 171
Description A previously detected PF Server Keep Alive Timeout has terminated
Trap Source BST/NPU
Trap Severity Info
Trap Category Equi