Table of contents

USER LEVEL

Display and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Operation start-up - language selection - device identification - standard display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6

Temperature settings required daytime temperature, required reduced temperature, required hot water temperature . . . . . . . . . . . . . . . . .7

Operational mode selection for heating and hot water (summary) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Function of operational modes holiday, absence, party, automatic, summer, permanent heating, permanent reduced heating, standby . . . . .9

Quick operational mode selection (automatic, party, absence, hot-water reloading) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Heating curve adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Heating system information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-133

Page 2

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 2

Page 3: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

PROGRAMMING LEVEL

LEVEL SUMMARY schematic block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-15

Level TIME PROGRAMS Programming, copying, reloading of standard programs, table for individual programs . . . . . . . . . . . . .16-22

Level TIME-DATE Time, calender year, calender month, calender day, automatic summer-/wintertime reset . . . . . . . . . . . . . .23

Level SYSTEM Language selection, clearing of time programs, control mode, summer switching-off . . . . . . . . . . . . . . . .22-26

Level DOMESTIC HOT WATER Economic temperature, legionella protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27

Level UNMIXED CIRCUIT Reduced mode, heating system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28-29

Alarm messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

Technical specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

Page 3

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 3

Page 4: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 4Display and Controls

Operating instruments

Operating modes button

Heating System Information

Heating curve adjustment

Setting daytime temperature

Setting domestic hot water temperature

Setting night setback

LCD-display

Rotary-push button

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 4

Page 5: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 5

The center-positioned rotary-push button and the labeled keys guarantee a simple and easy operation.It is however recommended to read this manual attentively to be informed about the repeating steps.– Each value in the display appears flashing and can be modified with the rotary-push button.

A flashing display is appropriately marked in this manual.Turn to the right (+): Increase valuesTurn to the left (-): Decrease values

– Press once: Acceptance of the selected and indicated value, store.– Keep pressed: Entry into the programming level (level selection),The last operation step will be stored automatically after approx. 60 seconds if it was not stored bymeans of the rotary-push button.

Turn: select parameters, change values

Press once: confirm, store

Start-upIn case of initiation of the plant or after every power failure a display test of the large display is car-ried out with automatic error diagnosis. At that all available segments and symbols will be displayed.

Language selectionIn case of first initiation the desired language can be chosen after the display test. The languages DE,GB, FR, IT, NL, ES, PT, HU, CZ, PL, RO, RU, TR, S, N, BG can be selected.Note: This display appears after every restart on day of first initiation until midnight. After that the

language can only be changed in the level SYSTEM - parameter LANGUAGE.

Symbolism used in this manual:

Operation

Language selection

Country codeGB

SPjACHWAHL

ff:f.ff.f.f.f.f

f.f.f.f.f.f.f.f.f.f.f.f

°CKWhmin%

¾ ¿ À Á Ä

°CKWhmin%

Display test

0 2 4 6 10 12 18 22208 14 16 24

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 5

Page 6: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 6Device identificationAfter the display test and/or the language selection the device identification momentary appearswith device type, interface and the corresponding number of software version.

Basic displayProvided that there is not any error message, the basic display indicates the date, time, heatingmode (

ë

= daytime temperature , ì

= reduced set back temperature ) as well as the current boi-ler temperature or, if released, the room temperature. Response time program. The cursor below( - ) indicates the current operating mode (see function of operating modes). The upper time barshows the heating periods and the corresponding operating times of the current weekday.

An activated summer switch-off is represented in the basic display by a sunshade symbol ( À ). The heating mode symbols

ë

or ì

will be suppressed during an activated summer switch-off.

With acting frost protection function an ice crystal symbol appears in the basic display ( Á ).

62.516:32

MO. 22. AUG.;05

°Cë

0 2 4 6 10 12 18 22208 14 16 24

Standard display Actual boiler temperatureresp. room temperature

V3.0OT

RSC

Device identification

Interface and software version

22.516:32

MO. 22. AUG.;05

°CÀ

0 2 4 6 10 12 18 22208 14 16 24

Standard display

Summer switching-off activated

22.516:32

MO. 22. AUG.;05

°C

0 2 4 6 10 12 18 22208 14 16 24

Standard display

Frost protection activatedÁ

Heating cycles

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 6

Page 7: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 7

Setting range: 5.0 ...30 °CFactorypreset: 20 °C

This button is used to set the required day-time room temperature

T This button is used to set the required setback room temperature

This button is used to set the requireddomestic hot water temperature

Adjustment (standard display mode only):

After pressing the button for the required tempe-rature the current value appears flashing and canbe adjusted directly with the rotary pushbutton.

Re-entry into the standard display is done by pres-sing the rotary-push button or the correspondingtemperature button or automatically after approx.60 seconds.

20.0

jOOM-DAY

°C

set

temperature

accept

Temperature settings

Setting range: 5.0 ...30 °CFactory preset: 16 °C

16.0

jOOM-NIGHT

°C

Setting range: 5...80 °CFactory preset: 50 °C

50.0

DHW

°C

Required daytimeroom temperature

Required set backroom temperature

Domestic hot water temperature

DAY

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 7

Page 8: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Operational mode selection for heating and hot waterWith this button the required operational mode is selected. It appears in plaintext on the display, simultanously a cursor at the lower edge ofthe display points to the appertaining program symbol.

Select: Pressing the button ¢

, the previously selected operational mode appears flashing. The other operational modes can be selected and activa-ted with the rotary-push button according to the following scheme.

Page 8

ABSENT TIL

STANDBY

27.08

HOLIDAY TIL

02:30

PAjTY TILHEATING

jED. HEATING

19:45

ABSENT TIL

AUTOMATIC

DHW

SUMMEj

Entry into the previously selected heating operation mode

27.08

HOLIDAY TIL

02:3015:3019:4515:30

PAjTY TIL

set date or time

Select required operational mode

Plant off during holiday

Extendheating operation

Domestic hotwater only

Interruptheating operation

Heating operationvia timer

Permanent heating operation

Permanent red.heating operation

Plant offfrost protection

accept, activate

activate, re-entry to standard display

Note: This mode is skipped in case of separate selection(see »Function of operating modes« and »LevelSYSTEM - parameter CONTROL MODE«)

15:30

æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 8

Page 9: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 9

Functions of operational modesPlant off

during holiday

24.0919:27

HOLIDAY TIL

19.3010:27

ABSENT TIL

02.2719:27

PAjTY TIL

19:27

MO. 22.AUG.;05

10:27

SUMMER

19:27

HEATING

19:27

jED. HEATING

19.019:27

STANDBY

°C

45.0

°C

72.0

°C

24.0

°C

56.5

°C

Interruptheating operation

Extendheating operation

Heating operationvia timer

Domestic hotwater only

Permanent heating operation

Permanent red.heating operation

Plant offfrost protection

Setting range:Actual date ...actualdate + 250 daysReturn to the previ -ously selected ope-rational mode at0.00 o’clock of theset return date. Hot water operati-on is set to frostprotection tempe-rature of 5 °C.

Earlier termination:Press button

¢

,select required ope-rational mode withrotary-push buttonand press again toactivate.

Operating times:(see level TIMEPROGRAMS)

Heating and do me -stic hot watero p e r a t i o nautomatically ac cor -ding to settings oftemperature valu es(see Temperature set-tings) and selectedoperating times pro-gram.

Programming of indi-vidual operating timessee level TIME PRO -GRAMS).

Setting rangeP1:Heating operation isinterrupted until nextswitching-on time ofcurrent operating timeprogram (see levelTIME PROGRAMS)

0.5 . . .24h: Heating operationis interrupted untilset time of return.Earlier termination:Press button

¢

,select required ope-rational mode withrotary-push buttonand press again toactivate.

Setting range:P1:Heating operation iscontinued until nextswitching-on time ofcurrent operating timeprogram (see levelTIME PROGRAMS)

0.5 . . .24h: Heating operationis continued untilend of party.Earlier termination:Press button

¢

,select required ope-rational mode withrotary-push buttonand press again toactivate.

Operating times:(see level TIME PRO-GRAMS)

Only hot water ope-ration according tosettings of hot watertemperature (seeTem perature settings)and selected opera-ting times program.The heating operati-on is interrupted andfrost protected.

Programming of indi-vidual operating timessee level TIME PRO -GRAMS).

Permanent heatingand reduced hotwater operationround the clockaccording to thesettings of daytimeroom temperatureand domestic hotwater temperature(see Temperaturesettings)

Permanent redu-ced heating andreduced hot wateroperation roundthe clock accordingto the settings of setback tempe rature(see Tempe ra turesettings), re ducedheating mode (seelevel UNMIXEDCIR CUIT) and hotwater economictem perature (seelevel DHW).

Heating and hotwater plant com-pletly switched offexcept for frostprotection mode.

æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í æ ç è é ê ë ì í

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 9

Page 10: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Manual hot water loadingTo activate manual hot water loading out-door of operation times the button

§

hasto be pressed for about 3 seconds. Thisturns on hot water preparation at any timefor a period which may to be adjusted withthe rotary pushbutton between 0 ...240minutes. Pushing the rotary pushbuttonactivates loading. Afterwards the controllerreturns to program operation. At adjustment 0.0 the loading is independentof any time period. The tank will be loadedup to the set DHW-temperature value once.

Short-time operational modesFrequently used operating modes such asPARTY or ABSENT or reloading the hotwater tank during set back mode can be sel-ected quickly according to the left scheme.

Direct automatic modePressing button

¢

for approx. 3 se condsactivates the automatic mode via timer in-evitably. Functions and setting range seeOperational mode selection for heating andhot water - Function of operational modes.

PAjTY TIL

modify

if required

Quick operational mode selection

ABSENT TIL

Setting range: 0...240 minFactory preset: 0.0 min

0.0

1 TIME DHW

Party mode Absence mode Manual hot water loading

Page 10

3 sec 3 sec3 sec

02:50 19:45

min

MO. 22. AUG.;05

activate

Automatic mode

3 sec

62.516:32

°C

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 10

Page 11: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

This button regulates the heating characte -ristics of the heating circuit in relation to out-door temperature.

The adjustment is dependent of the plant installation andshows the relation between outdoor temperature andheat generator (boiler) temperature. The slope sets the change of the supply temperature, if theoutdoor temperature changes for 1 K.

Re-entry into the standard display is done be pressingthe button

£

again or automatically after approx. 60 seconds.

Heating system information

Page 11

Diagram of heating curves2.00

1.75

1.50

1.25

1.00

0.75

0.50

0.20

20 16 12 8 4 0 -4 -8 -12 -16 -20 Outdoor temp.(°C)

100

90

80

70

60

50

40

30

20

Hea

t gen

erat

or te

mpe

ratu

re (

°C)

(factory preset)1.50HC

HEAT.CURVE

Setting range: OFF (heating circuit eliminated)0,20...3,50

Factory preset: 1,50

Modify

Slope

Store modification

Note: The heating slope should be modified only in small stepsand left for a while until steady condition can be obtained.Changes to the slope should be made in intervalls of 0.1every 1 or 2 days.

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 11

Page 12: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

This button displays all plant temperaturesand states of all circuits. The information canbe requested according to the direction withthe rotary-push button.

Turning rotary-push button clockwisedisplays from all plant-specific temperatures– the actual values and– the nominal values (pressing rotary-push button)

– meter readings such as consumption data etc.

Turning rotary-push button anti-clockwise

displays from direct heating circuit resp. DHW circuit

– operational mode (holiday, absence, party, auto etc.)– timer programm P1( P2 and P3 only when released)– heating mode (daytime-, reduced-, ECO-mode)– identification (direct circuit HC, hot water circuit DHW)– status of heating- and DHW charging pump (on, off)

Inquire clockwise temperatures, consumptiondatas one after the other

Examples:

Inquire anti-clockwise heat circuit informationone after the other

Examples:

13.5

OUTSIDE

°C

Outdoor temperature

Page 12

ONHC

AUTO-P1 DAY

14.58.0

OUT MIN/MAX

65.0

HEAT GENEj.

°C

°C

Outdoor temperatur Minimum-maximum valuebetween 0.00h and 24.00h

Heat generator temperature(boiler temperature)

°C

ON

HEAT GENEj.

OFFDHW

AUTO-P1 DAY

Heat generator (boiler)

Domestic hot water circuit

1245

STAjTS Heat generator starts(number of starts)

45.0

jETUjN FLOW

135.0

EXHAUST

Return flow temperature(only with return flow sensor)

Flue gas temperature(only with flue gas sensor)

°C

°C

Direct heating circuit(unmixed)

Entry into information levelHeating systeminformation

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 12

Page 13: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page13

shows – operating status (on, off)– number of service hours – number of startsof heat generator, boiler etc.

shows– room thermostat function (heating on, off)– current room temperatureif room sensor is activated

shows– water pressureif pressure sensor is present

258

OPER. HOURS Heat generator run timenumber of service hours

52.0

DHW

OFFDHW

THEjMOSTAT

°C

Hot-water temperature(electronically controlled)

Hot-water thermostat 1)

(mechanically controlled)

Room thermostat function 2)

room max. temp. delimitation

21.0

OFFHC

THEjMOSTAT

Room temperature 2)

Direct heating circuit°C

resp.

1) display dependent on the type of heat generator2 will be displayed only if the room sensor was activated before

ROOMTEMP HC

1.4

HYDRAU. PRESS

Hydraulic pressure 1)

(only it pressure sensor is pre-sent)

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 13

Page 14: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Standard display

(Example: Operational mode AUTOMATIC)

Entry into the level selection press knob for approx. 5 seconds

Programming level - Level summarySchematic block diagram

Page 14

TIME-DATE

58.519:45

MO. 22.AUG. ;05

°C

SYSTEMTIMEPROGRAMSDOMESTIC HOTWATER (DHW)

UNMIXEDHEATING CIRCUIT

TIME

YEAR

LANGUAGE

TIME PROGRAMP1 P1-P3

back forward

SELECT CIRCUITHC (Heating)

DHW (Hot water)

WEEKDAY (Mo-Su)Heating cycle (1...3)Copying function

ECO-TemperatureDHW-night

LEGIONELLAPROTECTION

Day 1-7)

REDUCEDHEATING

ECO/Reduction

HEATING SYSTEMm-value

Underfl./rad./conv.

Select

Level

Entry:

D GB F I

back forward back forward

back forward

back forward

back forward

back forwardback forward

0 2 4 6 10 12 18 22208 14 16 24

3sec

HEATING CIRCUIT NAME

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 14

Page 15: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Selection and modification of parameters andsetting values

Entering into the programming level, principally the operating timeslevel (TIME PROGRAMS) appears at first. All other levels, such as

- SYSTEM

- DHW

- UNMIXED CIRCUIT

- DATE-TIME

can be selected directly via rotary-push button

By pressing the rotary-push button, the selected flashing level isactivated; the first value resp. parameter appears flashing. If neces-sary, it can be modified via the rotary-push button and accepted bypressing again. If necessary, the following parameters can be trea-ted in the same way.

Re-entry into the level selection is done via the info button ¤

, re-entry into the standard display via the program-selection button

¤

or automatically after approx. 60 seconds.

Page 15

HEATING ENDselected cycle

TEMPERATUREselected cycle

DAY-MONTH

CHANGEOVERSummer-Wintertime

HEATING STARTselected cycle

OPERATING MODEcommon (1)separate (2)

SUMMERswitching off

PARAM.-RESETReset to factory

preset

back forward

back forward

back forward

back forward

back forward

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 15

Page 16: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 16

Select

Press for approx. 3 seconds

Programming of operating times

62.515:30

MO. 22. AUG.;05

°C

TIMEPjOGjAMS

HC

TIMEPjOGjAMS

DHW

TIMEPjOGjAMS

Enter operating times level

Standard display

accept

For example unmixed heating circuit HC

accept

With this mode of operation individual programs, other than standard programs for heating and hot-water mode can be set up. For this purpose after selecting the heating- resp. hot-water circuit the factory preset standard program (P1) is called an can be overwritten individually.

For programming the operation times, for each week day maximum three heating cycles with oneswitch-on and switch-off time each are available. Further more, the heating- resp. hot-water cycle canbe combined with a required room temperature resp. hot-water temperature for the duration of thecycle.

select program P1...P3, if released

heating circuit

3sec

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 16

Page 17: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

accept

For example Tuesday - heating cycle 120.0

MO-1

06.00-22.00

0 2 4 6 10 12 18 222014 16 24

°C

--.-MO-2

--.-----.--

0 2 4 6 10 12 18 2014 24

°C

8

20.0TU-1

06.00-22.00

0 2 4 6 10 12 18 222014 16 24

°C

8

--.-TU-2

--.-----.--

0 2 4 6 10 12 18 222014 16 24

°C

8

--.-SU-2

--.-----.--

0 2 4 6 10 12 18 222014 16816 22

- Wed - Thu - Fri - Sa t - Sun -

20.0TU-1

06.00-22.00

0 2 4 6 10 12 18 222014 16 24

°C

8

20.0TU-1

06.00-22.00

0 2 4 6 10 12 18 222014 16 24

°C

8

20.0TU-1

06.00-22.00

0 2 4 6 10 12 18 222014 16 24

°C

8

Select

Modify Setting range 0.00...24.00 h

Setting range: 0.00...24.00 h

For heating circuit: Room temperaturSetting range: 5.0...30.0 °C

For hot-water circuit: Hot-water temperatureSetting range: 10.0...80 .0 °C (resp. DHW-max)

Note: The 3rd heating cycle is skipped if the 2nd

heating cycle does not include any opera-ting times.

accept

accept

accept

Modify - Exit :

Confirm the selected flashing value by pres-sing the rotary-push button. Then set the newrequired value and take over by pressingthe rotary-push button again.

Re-entry into the former step in done bypressing the button

¤ , exit into the stan-dard display via the button

¢

or automati-cally after approx. 60 seconds.

8

day and cycle

Modify switching-offtime

Modify temperature

switching-ontime

Page 17

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 17

Page 18: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 18

Select

Push for approx. 3 seconds

Copy operating times

62.515:30

MO. 22. AUG.;05

°C

TIMEPjOGjAMS

HC

TIMEPjOGjAMS

DHW

TIMEPjOGjAMS

Enter operating times level

Standard display

heating circuit

accept

For example unmixed heating circuit HC

accept

DAY

COPY

20.0MO-1

06.00-22.00

0 2 4 6 10 12 18 222014 16 24

°C

8

copy functionSelect

Programming of operating times includes a extensive copying function which allo-ws to copy any day of the week to other days (Mo..Su) resp. to the whole week(1-7) or parts of a week such as workdays (1-5) or weekends (6-7).

select program P1...P3, if available

3sec

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:31 Seite 18

Page 19: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 19

Source and destination are identical

Setting range: Days (MO...SU) , whole week (1-7), Working days (1-5), weekend (6-7)

accept

Example: MondayMOFjOM

COPY

Select source

Select

Confirmation

If necessary select and takte over furtherdestinations in the same way.

Copy

1-5TO

COPY MO

OKDAY

COPY

Setting range: Monday (MO)...Sunday (SU)

TO

COPY MO

Select next destination

Example: Monday to Friday

Example: Saterday and Sunday6-7

etc..

first destination

Modify - Exit :

Confirm the selected flashing value by pres-sing the rotary-push button. Then set the newrequired value and take over by pressingthe rotary-push button again.

Re-entry into the former step in done bypressing the button

¤ , exit into the stan-dard display via the button

¢

or automati-cally after approx. 60 seconds.

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 19

Page 20: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 20

Select

Push for approx. 3 seconds

Reloading of standard time programs - deleting of individual time programs

62.515:30

MO. 22. AUG.;05

°C

TIMEPjOGjAMS

HC

TIMEPjOGjAMS

DEFAULT-TIME

Enter operating times level

Standard display

accept

For example unmixed heating circuit HC

accept

Modify - Exit :Confirm the selected flashing value by pressing the rotary-push but-ton. Then set the new required value and take over by pressing therotary-push button again.

Re-entry into the former step in done by pressing the button ¤ ,

exit into the standard display via the button ¢

or automatically afterapprox. 60 seconds.

heating circuitSelect DEFAULT-TIME

HC

DEFAULT-TIME

DHW

DEFAULT-TIME

ALL

The standard programs do not get lost by overwriting with individualprograms. Individual programs however are cancelled at a later callof the corresponding standard programs and have to be set upagain. For this purpose individual switching-on and switching-off timesshould always be noted (see level TIME PROGRAMS - table for indi-vidual programs).

default time

3sec

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 20

Page 21: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Reset

jESET

OK

press approx. 3 seconds

Standard program was reloadedIndividual Program was deleted!!

select program P1...P3, if released 1)jESET

HC

accept

Page 21

Standard time programs

Standard operating-times program P1

Circuit Day Heating from...to

Mo-Su 06.00 - 22.00 h Unmixed heating circuit (HC)

Mo-Su 05.00 - 22.00 h Domestic hot water (DHW)

1) see level SYSTEM - parameter PROGRAM

Standard operating-times program P1 1)

Circuit Day Heating from...to

Mo-Th 06.00-08.00 16.00-22.00h

Fr 06.00-08.00 13.00-22.00hUnmixed heating circuit (HC)

Sa-Su 07.00-23.00h

Mo-Th 05.00-08.00 15.30-22.00hDomestichot water (DHW)

Fr 05.00-08.00 12.30-22.00h

Sa-Su 06.00-23.00h

Standard operating-times program P3 1)

Circuit Day Heating from...to

Mo-Fr 07.00-18.00 h

Sa-Su reduced heating

Unmixed heating circuit (HC)

Mo-Fr 06.00-18.00 h Domestic hot water (DHW) Sa-Su reduced heating

3sec

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 21

Page 22: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Day

Mon

Unm

ixed h

eating c

ircuit (

HC

)

Tue

Wed

Thu

Fri

Sat

Sun

1st cycle From till

2nd cycle from till

3rd cycle from till

1st cycle from till

2nd cycle from till

3nd cycle from till

1st cycle from till

2nd cycle from till

3rd cycle from till

Operating times program P1 Operating times program P2 Operating times program P3

Day

Mon

Dom

est

ic h

ot-

wate

r ci

rcuit

(DH

W)

Tue

Wed

Thu

Fri

Sat

Sun

1st cycle from till

2nd cycle 2from till

3rd cycle from till

1st cycle from till

2nd cycle from till

3rd cycle from till

1st cycle from till

2nd cycle from till

3rd cycle from till

Page 22Table for individual operating times and programs

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 22

Page 23: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 23

TIME-DATE

18:45

TIME

22.08MO

DAY-MONTH

AUTOSU-WI

CHANGE

2005

YEAj

Current timeSetting range:0.00. . . 24.00 h

Calender yearSetting range:2001. . . 2099

Calender day-month-weekdaySetting range: 01.01. . . 31.12.Weekday is set automatically

Time changeover modeSetting range:Automatic: last Sunday in March & Oct.Manual: no time reset

Entry:

The values to the left are factory presets and normally neednot be updated. If in some exceptional cases corrections shouldbe necessary, the values can be adapted to the real conditions.The internal pre-programmed calender provides an automatictime changeover at the yearly repeating summer-wintertimedates. If required, the automatic time changeover can be switched off(manual reset).

TIME-DATEEntry: see » Programming level - Level summary « .

Exit: via button ¢

or automatically after 60 seconds

Modify: Confirm selected flashing parameter by pressingthe rotary-push button. Then set the new requi-red value via and accept by pressing the rotary-push button again. If necessary, correct the fol-lowing parameters in the same way.set time

set day & month

set changeover

set year

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 23

Page 24: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 24

Entry:

SYST.

SYSTEM

GB SYST.

LANGUAGE

P1

PjOGjAM

LanguageSetting range:DE = German GB = English FR = FrenchIT = Italian NL = Dutch ES = SpanishPT = Portuguese HU = Hungarian CZ = CzechPL = Polish RO = Romanian RU = RussianTR = Turkish S = Swedish N = NorwegianBG = BulgarianFactory preset: DE

Operating times programSetting range: P1, P1-P3Factory preset: P1

SYST.

SYSTEM

All information that appears in the display, is available in a num-ber of languages. After entry as first parameter appears the lan-guage selection. The required language can be selected and accep-ted according to the above assignment.

Application: Use of the instrument at the correspondinglanguage area.

This parameter specifies the number of the released time pro-grams. With setting P1 only one operating-times program is avai-lable, with setting P1-P3 all three programs are released and canbe selected for programming operating times.

Application: Shift work, different programs for summer, transition period, winter etc.

This level includes general delimiting parameters and optionsreferring to the corresponding heating system

Entry: see » Programming level - Level summary « .

Exit: via button ¢

or automatically after 60 seconds

Modify: Confirm selected flashing parameter by pressingthe rotary-push button. Then set the new requi-red value via and accept by pressing the rotary-push button again. If necessary, correct the fol-lowing parameters in the same way.

next parameter

next parameter

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 24

Page 25: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

1SYST.

CONTjOL MODE

Control mode

Setting range: 1 = common mode 2 = separated modeFactory preset: 1

HC

OP. MODE

Select

Circuit

accept

Operational mode

further operation see »Operational mode selection for heating and hot water« and »Temperature settings«Page 25

Common control mode:The selected operational mode (via button

¢

for Holiday,Absence, Party, Automatic etc.) applies to the heating circuit and tothe hot-water circuit together.

Separated control mode:The heating- and hot-water circuit can be assigned with ownoperational mode.

Application: Objects with uniform seizure character (One-family houses etc).

Application: Objects with different use of heating and hot-water (for example heating operation inHoliday mode, hot-water permanently in redu-ced mode).

next parameter

Unmixed circuit (HC), hot-water circuit (DHW)

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 25

Page 26: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 26

20.0

SUMMER

Summer switch-offSetting range: OFF, 10.0 to 30,0 °CFactory preset: 20.0 °C

SYST.

°C

Note: The active summer switch-off appears on the standarddisplay with a sunshade symbol.

Application: All objects which do not require a heating ope-ration during summertime

This parameter specifies the heating delimiting value regardingthe average resp. current outside temperature and puts theheating system automatically out of service as soon as the out-side temperature exceeds the set heating delimiting value.During summer switch-off the pump of the heating circuit isactivated each day for approx. 10 seconds to protect it againstcorrosion.

With setting OFF the summer switch-off is not effective.

Hot water preparation is not affected by summer switch-off.

Summer switch-off activated

jESET

Reset: Press rotary-push button for approx. 5 sec. whileindi cation SET is flashing, until standard displayappears.

SYST.

Parameter-resetThis function resets all individually entered values in the pro-gramming level to factory preset.

Exception: Time-date, operating times

SET

jESET

SYST.

next parameter

Important: Reset may only be executed if all individuallyentered values shall be replaced by the factorypreset values!!

63.516:32

MO. 22. AUG.;05

°CÀ

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 26

Page 27: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 27

40.0NIGHT

DHW

OFF

LEGION.PjOT.

Hot-water economic temperatureSetting range: 5.0 °C up to the required hot water temperatureFactory preset: 40.0 °C

Legionella protection (day)Setting range: OFF, MO...SU, ALLFactory preset: OFFDAY

This parameter determines the amount of the reduced hot-watertemperature outside the hot-water operating times (between thehot-water cycles) as well as in the operational mode ABSENCEfor the duration of absence.

The legionella protection serves to avoid a legionella infestationinside the hot-water tank and is activated on the selected week-day (Mon to Sun) or every day at 2.00 o’clock. If the hot-watertemperature should drop below 65 °C, the tank is reloaded. With setting OFF this function is not effective.

°C

DHW

DHW

DOMESTIC HOT WATERThis level includes the necessary parameters for programming thehot-water circuit except the hot-water operating-times.

Entry: see » Programming level - Level summary « .

Exit: via button ¢

or automatically after 60 seconds

Modify: Confirm selected flashing parameter by pressingthe rotary-push button. Then set the new requi-red value via and accept by pressing the rotary-push button again. If necessary, correct the fol-lowing parameters in the same way.

Application: Base temperature inside the hot-water tank inorder to avoid a cooling down of the tank.Note: This parameter is skipped if a hot-water thermostat is

used instead of an electronic hot-water sensor.

Note: Other legionella protection times can be regulatedexclusively by the heating plant specialist.

Important: Danger of scalding! Use thermostatic mixingvalve on DHW outlet.

Entry:

next parameter

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 27

Page 28: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 28

HC

UNMIXED CIRC.

ECOHC

jED.HEATING

Reduced heating mode

Setting range: ECO, REDFactory preset: ECO

Unmixed heating circuit (direct circuit)This level includes the parameters required for programmingthe heating circuit with the exception of the related operating-times programs.

Entry: see » Programming level - Level summary « .

Exit: via button ¢

or automatically after 60 seconds

Modify: Confirm selected flashing parameter by pressingthe rotary-push button. Then set the new requi-red value via and accept by pressing the rotary-push button again. If necessary, correct the fol-lowing parameters in the same way.

Application: Objects with high insulation values

Application: Objects with low insulation values

During the reduced operation the following modes can be selected:ECO mode: At oudoor temperatures above the set plant frost

protection the heating circuit is switched off com-pletely. At temperatures below frost protection theheating circuit is controlled with reduced heatingcharacteristic according to the required reducedtemperature (see »Temperature setting« ).

RED mode: During the reduced mode the heating circuit pumpremains activated. The heating circuit is controlledaccording to the reduced heating characteristic,the temperature does not drop below the set mini-mum temperature value.

Entry:

next parameter

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 28

Page 29: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Heating curve for underfloor heating systemsor other static heating surfaces

Normal standard heating curves for radiators

Heating curves for convectors

Special heating curves for ventilators withhigh starting temperatures

1.00. . . 1.10

ApplicationSetting value

1.30. . . 2.20

3.00. . . 4.00

4.00. . . 10.0

Page 29

1.30

HEAT. SYSTEM

Adaptation to the heating system

Setting range: 1,00 to 10.0Factory preset: 1,30

HC

Applications:The following setting values are recommended for the below-mentioned applications

This parameter refers to the type of the heating systemand has to be adapted to the power characteristic of thecorresponding consumer (underfloor systems, radiator,convector). The setting value specifies the curvature of theheating curve of the selected weather dependent heatingcircuit and compensates the system-related efficiency los-ses at lower temperatures by a progressive heating curvein conformity with the adjustment.

Heating circuit nameThis is used to assign an individual, 5 character, abbrevia-ted name to each heating circuit. No individual name is assigned if the setting "empty" isused. The default abbreviated name appears.• The character that blinks can be altered using the rotary

knob according to the code number and accepted bypressing the knob once. The remaining characters canbe altered in the same way.

• The individual heating circuit name display appears- in the menu- in the parameter tree- in the info level

HC-NAME

HC-NAME

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 29

Page 30: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Page 30

Example for alarm message »data bus« (address error)Error code 70

The instrument is equipped with an extensive error diagnostic fea-tures. The error displayed takes priority over other displays andvaries dependent on the model in question.

For alarm messages from burner control (ERROR Xn:m) the errorcodes in the corresponding installation manuals have to be conside-red.

Note: Alarm messages only appear alternating with the stan-dard display.

In case of alarm messages the heating specialist alwayshas to be informed!

10-0EjjOR

OUTSIDE

30-nEjjOR

HEAT GEN.

50-4EjjOR

DHW

70-nEjjOR

BUS

Example for alarm message »sensor« (short or open circuit)Error code 10...20

Example for alarm message »heat generator«(flue gas temperature exceeded)Error code 30...40... 1)

Example for logical alarm messages (control functions) Error code 50. . .60

Alarm messages

!

1) For these alarm messages the error codes of the heat generator in thecorresponding installation manuals have to be considered.

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 30

Page 31: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

Technical specification

Supply voltage: Via data bus (DC-safety voltage by EN 60730)

Power consumption: 300 mW

Bus interface: T2B or OpenTherm according to model

Ambient temperature: 0...60 °C

Storage temperature: -25...60 °C

Protection type acc. to EN 60529: IP 30

Protection class acc. to EN 60730: III

Approval according to: VDE 60730

Casing dimensions (BxHxD): 90 x 138 x 28 mm

Casing material: ABS, antistatic

Electrical connections: 2-wire mode with plugable connection

Recommended cable: J-Y(St)Y 2 x 2 x 0.6 mm2

Max. length of cable: 50 m

Data and timer back up: Min. 5 years from date of delivery

Accuracy of the internal clock ± 2s/dayWeight: Approx. 150 g

Subj

ect t

o ch

ange

Art

. 045

0017

010

- 10

10-3

0

0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck:0450017010_1010-30_BA_THETA RSC(-OT)_EbV_GB_Druck.qxp 05.03.2010 10:32 Seite 32

Page 32: BrainQ RSC BrainZ RSC O p e n T h e r m - Compano

www.atagheating.com