APPLICATIONS:Type N (T/N) cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
*Add A for aluminum armor and B for bronze armor. (ie. DNIA-4)
SPECIFICATIONS:1. CONDUCTOR: Stranded soft annealed copper, tinned or alloy coated where necessary, class B strand2. INSULATION: Thermoplastic Nylon.3. COLOR CODED: Black and white. Per IEEE-45 standards4. ASSEMBLY: Conductors are cabled together with non hygroscopic fillers for a circular cross section.5. JACKET: Thermoplastic jacket complying with table A11 or supplements.6. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.*7. OPTIONAL SHEATH: Optional PVC outer jacket.
PartNumber
DNI-3DNI-4DNI-6DNI-10DNI-16DNI-26DNI-41DNI-66DNI-83DNI-106DNI-133DNI-168DNI-212DNI-250DNI-350DNI-500
1614121086427
1/02/03/04/0250350500
155155155205306306408408509509509509509
601060106010
4545454560606080808080808080
110110
0.3000.3300.3700.4300.5800.6500.8000.9701.0001.1801.2701.3801.5601.6201.9002.170
ConductorSize
AWG/kMils PVC/NYL
Overall Jacket
Thickness
Mils
UnarmoredOutside
Diameter
0.3600.3800.4200.4800.6300.7000.8501.0201.0501.2301.3201.4301.6101.6701.9502.220
586688
133213311479727933
1110132316022122233733034497
Aluminum ArmoredWeight
7284
108155246344520776983
1170138516712200241833484605
InsulationThickness
Mils
IN
ArmoredOutside
DiameterUnarmored
Weight
Lbs/1000Ft
Ampacity45ºC
AmbientTempAmps
13212834446076
104121139170186215240297264
OPTIONAL: Aluminum or Bronze Armor
DNI (DT/NT) 2 Conductors Power and Control - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyd's Register of Shipping
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com
BOSTMARINECommercial Marine Shipboard
OPTIONAL: Aluminum or Bronze ArmorAPPLICATIONS:Type N (T/N)cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
SPECIFICATIONS:1. CONDUCTOR: Stranded soft annealed copper, tinned or alloy coated where necessary, class B strand2. INSULATION: Thermoplastic Nylon.3. COLOR CODED: Black, white and red. Per IEEE-45 standards4. ASSEMBLY: Conductors are cabled together with non hygroscopic fillers for a circular cross section.5. JACKET: Thermoplastic jacket complying with table A11 or supplements.6. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.*7. OPTIONAL SHEATH: Optional PVC outer jacket.
PartNumber
TNI-3TNI-4TNI-6TNI-10TNI-16TNI-26TNI-41TNI-66TNI-83TNI-106TNI-133TNI-168TNI-212TNI-250TNI-350TNI-500
1614121086427
1/02/03/04/0250350500
155155155205306306408408509509509509509
601060106010
4545454560606080808080808080
110110
0.300.350.390.460.610.690.841.021.161.241.361.451.591.802.052.45
ConductorSize
AWG/kMils PVC/NYL
Overall Jacket
Thickness
Mils
UnarmoredOutside
Diameter
0.350.400.440.510.660.740.941.071.211.291.411.501.641.852.102.50
7486
120171301406664980
12281557182822442773336045506472
Aluminum ArmoredWeight
92104140195332441709
103112861619189623162852345046526594
*Add A for aluminum armor and B for bronze armor. (ie. TNIA-4)
InsulationThickness
Mils
IN
ArmoredOutside
DiameterUnarmored
Weight
Lbs/1000Ft
Ampacity45ºC
AmbientTempAmps
11242938486583
111131150173201232259317393
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com
TNI (TT/NT) 3 Conductors Power and Control - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyd's Register of Shipping
BOSTMARINECommercial Marine Shipboard
BOSTMARINECommercial Marine Shipboard
*Add A for aluminum armor and B for bronze armor. (ie. FNIA-4)
SPECIFICATIONS:1. CONDUCTOR: Stranded soft annealed copper, tinned or alloy coated where necessary, class B strand2. INSULATION: Thermoplastic Nylon.3. COLOR CODED: Black, white, red and green. Per IEEE-45 standards4. ASSEMBLY: Conductors are cabled together with non hygroscopic fillers for a circular cross section.5. JACKET: Thermoplastic jacket complying with table A11 or supplements.6. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.*7. OPTIONAL SHEATH: Optional PVC outer jacket.
FNI-3FNI-4FNI-6FNI-10FNI-16FNI-26FNI-41FNI-66FNI-83FNI-106FNI-133FNI-168FNI-212FNI-250FNI-350FNI-500
1614121086427
1/02/03/04/0250350500
155155155205306306408408509509509509509
601060106010
4545454560606080808080808080
110110
0.330.390.430.510.660.770.991.131.271.381.491.611.821.982.342.56
0.380.440.480.560.710.821.041.181.321.431.541.661.872.032.392.61
92111139207339507825
119715101824225227393475410355757692
111129163235373543874
125515761891232728193568420756977822
Amps
11242938486583
111131150173201232259317393
OPTIONAL: Aluminum or Bronze ArmorAPPLICATIONS:Type N (T/N) cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com
PartNumber
ConductorSize
AWG/kMils PVC/NYL
Overall Jacket
Thickness
Mils
UnarmoredOutside
Diameter
Aluminum ArmoredWeight
InsulationThickness
Mils
IN
ArmoredOutside
DiameterUnarmored
Weight
Lbs/1000Ft
Ampacity45ºC
AmbientTempAmps
FNI (FT/NT) 4 Conductors Power and Control - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyd's Register of Shipping
APPLICATIONS:Type N (T/N) cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
*Add A for aluminum armor and B for bronze armor. (ie. MNIA-4)
OPTIONAL: Aluminum or Bronze Armor
SPECIFICATIONS:1. CONDUCTOR: Stranded soft annealed copper, tinned or alloy coated where necessary, class B strand2. INSULATION: Thermoplastic Nylon.3. COLOR CODED: Per IEEE-45 standards (see Technical Reference Section)4. ASSEMBLY: Conductors are cabled together with non hygroscopic fillers for a circular cross section.5. JACKET: Thermoplastic jacket complying with table A11 or supplements.6. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.*7. OPTIONAL SHEATH: Optional PVC outer jacket.
PartNumber
MNI-7-3MNI-10-3MNI-14-3MNI-20-3MNI-24-3MNI-30-3MNI-37-3MNI-7-4MNI-10-4MNI-14-4MNI-20-4MNI-24-4MNI-30-4MNI-37-4MNI-6-6MNI-7-6MNI-10-6MNI-14-6MNI-24-6
71014202430377
10142024303767
101424
155155155155155155155155155155155155155155155155155155155
45606060808080456060808080806060606060
0.390.500.560.620.720.770.870.440.580.630.710.810.900.960.520.520.660.720.98
Number of Conductors PVC/NYL
Overall Jacket
Thickness
Mils
UnarmoredOutside
Diameter
0.450.550.610.670.770.820.920.490.630.680.760.860.951.010.570.570.710.771.03
114159226295358431556157240308409949639762200230330450800
Aluminum ArmoredWeight
135185255327395470600180270340445535685810
InsulationThickness
Mils
IN
ArmoredOutside Unarmored
Weight
Lbs/1000Ft
Ampacity450C
AmbientTempAmps
85555549999887
ConductorSize
AWG/kcMils
16161616161616141414141414141212121212
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com
MNI (C16T/NT) (C14T/NT) Multi Conductors Power and Control - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyd's Register of Shipping
BOSTMARINECommercial Marine Shipboard
BOSTMARINECommercial Marine Shipboard
PartNumber
DXI-4DXI-6DXI-10DXI-16DXI-26DXI-41DXI-66DXI-83DXI-106DXI-133DXI-168DXI-212DXI-250DXI-350DXI-500DXI-750
14121086421
1/02/03/04/0250350500750
0.380.420.470.630.710.810.981.111.191.291.401.521.651.942.222.63
ConductorSize
AWG/kMils
UnarmoredOutside
Diameter
0.430.470.520.680.760.861.031.161.241.341.451.571.701.992.272.68
77100153225315436671842
10101223150418032117297140675916
Aluminum(Bronze)ArmoredWeight
145 (185)165 (210)240 (295)335 (385)470 (550)625 (705)780 (885)885 (985)
1095 (1215)1445 (1580)1759 (1895)2065 (2215)2565 (2725)3300 (3500)4460 (4670)6445 (6785)
*Add A for aluminum armor and B for bronze armor. (ie. DXIA-4)
IN
ArmoredOutside Unarmored
Weight
Lbs/1000Ft.
Ampacity45ºC
AmbientTempAmps
2936466079
101137161183233245284316387479602
OPTIONAL: Aluminum or Bronze ArmorAPPLICATIONS:Type X (X) cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
SPECIFICATIONS:1. CONDUCTOR: Stranded bare copper, tinned or alloy coated where necessary, class B strand2. INSULATION: Crosslinked Polyethelene (XHHW)3. COLOR CODED: Black and white. Per IEEE-45 standards4. ASSEMBLY: Conductors are cabled together with non hygroscopic fillers for a circular cross section.5. JACKET: Thermoplastic jacket complying with table A10, A11, A12 or supplements.6. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.*7. OPTIONAL SHEATH: Optional PVC outer jacket.
Lbs/1000Ft.
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com
DXI (DXT) 2 Conductors Power and Control - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyd's Register of Shipping
BOSTMARINECommercial Marine Shipboard
TXI-4TXI-6TXI-10TXI-16TXI-26TXI-41TXI-66TXI-83TXI-106TXI-133TXI-168TXI-212TXI-250TXI-350TXI-400TXI-500TXI-750
14121086421
1/02/03/04/0250350400500750
0.400.450.500.670.750.901.041.181.271.381.491.631.832.082.252.372.81
0.450.500.550.720.800.951.091.231.321.431.541.681.882.132.302.422.86
98130178300419641925
1145140117042085252431393818434958468776
175 (210)230 (265)300 (340)420 (480)610 (665)840 (905)
1130 (1210)1400 (1498)1660 (1790)1820 (1960)2180 (2330)2540 (2710)3340 (3530)3934 (4154)4468 (4712)6160 (6410)9190 (9490)
*Add A for aluminum armor and B for bronze armor. (ie. TXIA-4)
242938486583
111131150173201232259317342393494
OPTIONAL: Aluminum or Bronze Armor
APPLICATIONS:Type X (X) cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
SPECIFICATIONS:1. CONDUCTOR: Stranded bare copper, tinned or alloy coated where necessary, class B strand2. INSULATION: Crosslinked Polyethylene (XHHW)3. COLOR CODED: Black, white and red. Per IEEE-45 standards4. ASSEMBLY: Conductors are cabled together with non hygroscopic fillers for a circular cross section.5. JACKET: Thermoplastic jacket complying with table A10, A11, A12 or supplements.6. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.*7. OPTIONAL SHEATH: Optional PVC outer jacket.
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com
PartNumber
ConductorSize
AWG/kMils
UnarmoredOutside
Diameter
Aluminum(Bronze)ArmoredWeight
IN
ArmoredOutside Unarmored
Weight
Lbs/1000Ft.
Ampacity45ºC
AmbientTempAmpsLbs/1000Ft.
TXI (TXT) 3 Conductors Power and Control - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyd's Register of Shipping
BOSTMARINECommercial Marine Shipboard
FXI (FXT) 4 Conductors Power and Control - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyd's Register of Shipping
APPLICATIONS:Type X (X) cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
U
14
14
11.52351015202530405060
14141414141414141414141414
.43
.48
.77
.80
.951.361.561.722.022.102.352.682.89
10.912.219.620.324.134.539.643.751.353.359.768.173.4
941192102804668491204165020382376307538074653
1151432473175119171282173921442484319839524809
NOM. CableO.D. (1)
(Inches) (mm)
Approximate Net WeightLbs/1000 ft
U
16420733340361410721459184123832739348442795156
A B
306089119149179208238268298328357387
Copper WeightLbs/1000 ft
APPLICATIONS:Type TPS (TP) cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
BOSTMARINECommercial Marine Shipboard
TPS14 (TP14 (IS-OS) T/NT) Twisted Pairs ShieldedInstrumentation - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyd's Register of Shipping
OPTIONAL: Aluminum or Bronze ArmorAPPLICATIONS:Type TPS (TP) cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com
BOSTMARINECommercial Marine Shipboard
TPS16 (TP16 (IS-OS) T/NT) Twisted Pairs ShieldedInstrumentation - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyd's Register of Shipping
*Add A for aluminum armor and B for bronze armor. (ie. TPS16CNIA-4)
SPECIFICATIONS:1. CONDUCTOR: #16 AWG -7/.0192" annealed bare copper ASTM B8.2. INSULATION: Polyvinylchloride .015" nominal wall. 3. COLOR CODED: One white and one colored per IEEE-45 standards.4. FILLER: Nylon.5. JACKET: Nylon .005" nominal wall.6. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.*7. INDIVIDUAL SHIELD: .001" Aluminum/Polyester.8. DRAIN WIRE: #16 AWG multi pair (Individual-#20 AWG- 7/.0121" TC, Overall-#18 AWG- 7/.0152" TC).9. INDIVIDUAL ISOLATION TAPE: .001" Aluminum/Polyester.10. OVERALL SHIELD: Small sizes- .0015" Aluminum/Polyester, Large sizes- .00235" Aluminum/Polyester.11. OVERALL JACKET: Gray PVC.
1234568
10121520
1616161616161616161616
0.2680.4360.4610.5050.5860.6360.6880.8040.8660.9641.066
48.787.5
126.7155.2205.3239.5299.7372.8465.5565.6723.9
0.3230.4910.5160.5600.6400.6910.7430.8590.9211.0191.121
63.280.2
147.7181.3235.4272.0344.8413.6509.3616.9777.5
Number of Pairs AWG
600V 90ºCTPS16CNIU TPS16CNIA
CN (PVC/Nylon) - Unarmored
CN (PVC/Nylon) - Aluminum Armored
Normal Diam. (in.)
Approx. Wt. (lbs/1000ft)
600V 90ºC
Normal Diam. (in.)
Approx. Wt. (lbs/1000ft)
OPTIONAL: Aluminum or Bronze Armor
APPLICATIONS:Type TPS (TP) cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
*Add A for aluminum armor and B for bronze armor. (ie. TPS18CNIA-4)
SPECIFICATIONS:1. CONDUCTOR: #18 AWG -7/.0152" annealed bare copper ASTM B82. INSULATION: Polyvinyl chloride .015" nominal wall 3. COLOR CODED: One white and one colored per IEEE-45 standards4. FILLER: Nylon5. JACKET: Nylon .005" nominal wall6. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.*7. INDIVIDUAL SHIELD: .001" Aluminum/Polyester8.DRAIN WIRE: #18 AWG multi pair (Individual-#22 AWG- 7/.0121" TC, Overall-#20 AWG- 7/.0152" TC)9.INDIVIDUAL ISOLATION TAPE: .001" Aluminum/Polyester10. OVERALL SHIELD: Small sizes- .0015" Aluminum/Polyester, Large sizes- .00235" Aluminum/Polyester11. OVERALL JACKET: Gray PVC
1234568
10121520
1818181818181818181818
0.2480.4030.4180.4570.5000.5760.6220.7240.7460.8700.960
39.774.397.3
121.8146.8189.2236.6291.3336.1442.5562.4
0.3030.4580.4730.5120.5550.6310.6770.7790.8010.9251.015
53.295.4
119.1145.6172.7218.8268.5328.2374.0486.5610.8
Number of Pairs AWG
600V 90ºCTPS18CNIU TPS18CNIA
CN (PVC/Nylon) - Unarmored
CN (PVC/Nylon) - Aluminum Armored
Normal Diam. (in.)
Approx. Wt. (lbs/1000ft)
600V 90ºC
Normal Diam. (in.)
Approx. Wt. (lbs/1000ft)
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com
BOSTMARINECommercial Marine Shipboard
TPS18 (TP18 (IS-OS) T/NT) Twisted Pairs ShieldedInstrumentation - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyds Register of Shipping
U
20
20
11.52351015202530405060
20202020202020202020202020
.31
.39
.48
.50
.53
.841.001.101.241.291.441.621.78
7.99.912.212.716.021.325.427.931.532.836.641.145.2
4054719114525338447557665883210051290
56729511517629343152863872390610881382
NOM. CableO.D. (1)
(Inches) (mm)
Approximate Net WeightLbs/1000 ft
U
82115159179252384540650781873107112781590
A B
81317254285127170212275340425510
Copper WeightLbs/1000 ft
APPLICATIONS:Type TPS (TP) cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
BOSTMARINECommercial Marine Shipboard
TPS20 (TP20 (IS-OS) T/NT) Twisted Pairs ShieldedInstrumentation - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine CableLloyd's Register of Shipping
OPTIONAL: Aluminum or Bronze Armor
APPLICATIONS:Type TTS (TT)cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
SPECIFICATIONS:1. CONDUCTOR: #16 AWG -7/.0192" annealed bare copper ASTM B8.2. INSULATION: Polyvinylchloride .015" nominal wall. 3. COLOR CODED: One white, red, and black (white numbered 1 through total number of Triads) per IEEE-45 standards.4. FILLER: Nylon.5. JACKET: Nylon .005" nominal wall.6. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.*7. INDIVIDUAL SHIELD: .001" Aluminum/Polyester.8.DRAIN WIRE: #16 AWG multi triad (Individual-#20 AWG- 7/.0121" TC, Overall-#18 AWG- 7/.0152" TC).9.INDIVIDUAL ISOLATION TAPE: .001" Aluminum/Polyester.10. OVERALL SHIELD: Small sizes- .0015" Aluminum/Polyester, Large sizes- .00235" Aluminum/Polyester.11. OVERALL JACKET: Gray PVC.
123456
161616161616
0.3200.5700.6000.6600.7250.790
0.3700.6200.6500.7100.7750.840
600V 90ºC 600V 90ºCTTS16CNIU TTS16CNIACN (PVC/Nylon) -
UnarmoredCN (PVC/Nylon) -
Aluminum Armored
Normal Diam. (in.)
*Add A for aluminum armor and B for bronze armor. (ie. TTS16CNIA-4)
Number of Triads AWG
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com
Normal Diam. (in.)
BOSTMARINECommercial Marine Shipboard
TTS16 (TT16 (IS-OS) T/NT) Twisted Triads ShieldedInstrumentation - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine Cable
OPTIONAL: Aluminum or Bronze Armor
APPLICATIONS:Type TTS (TT)cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wireways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
SPECIFICATIONS:1. CONDUCTOR: #18 AWG -7/.0192" annealed bare copper ASTM B8.2. INSULATION: Polyvinyl chloride .015" nominal wall. 3. COLOR CODED: One white, red, and black (white numbered 1 through total number of Triads) per IEEE-45 standards.4. FILLER: Nylon.5. JACKET: Nylon .005" nominal wall.6. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.*7. INDIVIDUAL SHIELD: .001" Aluminum/Polyester.8.DRAIN WIRE: #18 AWG multi triad (Individual-#22 AWG- 7/.0121" TC, Overall-#20 AWG- 7/.0152" TC).9.INDIVIDUAL ISOLATION TAPE: .001" Aluminum/Polyester.10. OVERALL SHIELD: Small sizes- .0015" Aluminum/Polyester, Large sizes- .00235" Aluminum/Polyester.11. OVERALL JACKET: Gray PVC.
123456
181818181818
0.2900.4800.5000.6000.6500.710
0.3400.5300.5500.6500.7000.760
600V 90ºC 600V 90ºCTTS18CNIU TTS18CNIACN (PVC/Nylon) -
UnarmoredCN (PVC/Nylon) -
Aluminum Armored
Normal Diam. (in.) Normal Diam. (in.)
*Add A for aluminum armor and B for bronze armor. (ie. TTS18CNIA-4)
Number of Triads AWG
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com
BOSTMARINECommercial Marine Shipboard
TTS18 (TT18 (IS-OS) T/NT) Twisted Triads ShieldedInstrumentation - 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine Cable
BOSTMARINECommercial Marine Shipboard
LSXL Low Smoke 2, 3, & 4 Conductors 600V, 900CIEEE Standard 45USCG and ABS AcceptedUL Marine Cable OPTIONAL: Aluminum or Bronze Armor
APPLICATIONS:Type LSXL (LSXL) low smoke cables are designed for use on commercial marine vessels. The cables may be used on work boats, tugs, fishing boats, casino boats, and other commercial vessels in addition to certain oil rig applications. These cables should be used for the distribution of power up to their voltage rating throughout the system, and may be used in lighting, communication, control, and electronic circuits as desired. Suitable for installation in trays, troughs, channels, conduit, and wire ways. Finished cables pass the IEEE-383 and IEEE Standard 1202 flammability test.
SPECIFICATIONS:1. CONDUCTOR: Class B stranded, soft drawn, bare copper per ASTM B3 and ASTM B82. INSULATION: Heat and moisture resistant, thermosetting, low smoke, cross linked polyethylene meeting the requirements of IEEE Std. 45. The insulation is suitable for use in locations at a temperature not exceeding 900C dry or 750C wet. The insulation thickness is in accordance with IEEE Std. 45.3. COLOR CODED: (2 conductors) black and white- (3 conductors) black, white, and red- (4 conductors) black, white, red, and green.4. ASSEMBLY: The insulated circuit conductors are cabled together with non hygroscopic fillers as needed. The cabled core shall be wrapped with a Mylar binder tape.5. JACKET: Heat and moisture resistant, black thermoplastic polyolefin meeting the requirements of IEEE Std. 45. The thickness is in accordance with IEEE Std. 45.6. SCOPE: Multi-conductor, 600 volt, Shipboard Cable with thermosetting low smoke cross-linked polyethylene (LSX) insulated circuit conductor, with an overall thermoplastic polyolefin (TPO) jacket.7. OPTIONAL ARMOR: Aluminum or bronze basket weave armor overall meeting the requirements of IEEE 45.**8. OPTIONAL SHEATH: Optional PVC outer jacket.
PartNumber
DLSXL-3DLSXL-4DLSXL-6TLSXL-3TLSXL-4TLSXL-6TLSXL-10FLSXL-3FLSXL-4FLSXL-6FLSXL-10
2/C #162/C #142/C #123/C #163/C #143/C #123/C #104/C #164/C #144/C #124/C #10
77777777777
3030303030303030303030
4545454545454545454545
Number & CircuitConductor
Size
awg strand
AverageInsulationThickness
(mils)
AverageJacket
Thickness(mils)
NominalCableOD(in.)
0.3500.3800.4150.3750.4000.4400.5000.4100.4400.4900.580
NominalCable
Weight(lbs./Mft)
7185
11182
103134184101127170254
Ampacity@450C
AmbientTemp.*(amps)
1829361524293812192330
*Per IEEE Std. 45 table 9-1. Distribution, control, and signal cables-single banked, maximum current carrying capacity (types T, T/N, E, X, LSE, LSX, and P @ 450 C ambient)**Add A for aluminum armor and B for bronze armor. (ie. DLSXLA-4)
1610 Greens Road, Suite 200Houston, Texas 77032
281.209.1070Fax: 281.209.3857
Toll Free: 888.354.CABL (2225)
www.drakausa.com