Boilers Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009

Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

  • Upload
    hanhu

  • View
    249

  • Download
    7

Embed Size (px)

Citation preview

Page 1: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

Boilers Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters

Updated: April 2009

Page 2: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

APR 2009 - 1

Introduction The Gas Appliance Manufacturers Association (GAMA) in 2008 merged with the Air-Conditioning and Refrigeration Institute to become the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). The newly merged association is now home to all of the industry’s equipment certification programs: I=B=R, GAMA Efficiency Rating Certified and ARI Performance Certified. AHRI tests boilers, baseboards, commercial finned tube radiation and indirect-fired water heaters and provides authorization for the use of I=B=R ratings for those products. AHRI is also engaged in other projects and activities to develop reliable technical data for the heating and the building industries, and to assure correct calculation, design, and installations of hydronic systems, providing maximum comfort at minimum cost to the consumer. Some of the projects include:

1. Development of Codes and Standards 2. Research and technical investigations into hydronic theory and practice 3. Publication of technical reports and installation guides reflecting the latest research and practical experience 4. Dissemination of data of value to manufacturers and to the heating industry. The Hydronics Institute

maintains its office and laboratory in its own building in Berkeley Heights, New Jersey About the Directory This directory contains the I=B=R Ratings for cast-iron, steel, aluminum and copper boilers, baseboard and finned tube radiation, indirect-fired water heaters, effective as of the date of this publication. These ratings have been determined under the provisions of the “I=B=R Rating Procedure for Heating Boilers,” “BTS-2000 Testing Standard for Commercial Space Heating Boilers”, “I=B=R Testing and Rating Standard for Baseboard Radiation,” “I=B=R Testing and Rating Standard for Finned Tube Radiation,” “GAMA Testing Standard for Performance of Indirect-Fired Water Heaters,” and “GAMA I=B=R Rating Procedure for Indirect-Fired Waters Heaters,” copies of which are available for purchase. For boilers under 300,000 Btu input, the I=B=R Procedural Guide includes the requirements of the U.S. Department of Energy. Any boilers claiming to have I=B=R ratings, but not listed herein do not have I=B=R approval as of the date of this publication. Visit the AHRI Directory of Certified Product Performance at www.ahridirectory.org to check for updates. The designation “SBI Ratings” has been discontinued. The designation “I=B=R Ratings” is now used for all boilers, regardless of construction material. Boiler model numbers may have prefix and/or suffix letters to indicate variations in the assembly, controls, trim, etc. Refer to the manufacturer’s catalog for an explanation of the letters used. Manufacturer’s catalogs are reviewed by AHRI to assure physical conformance with the product as it was when tested. Boiler ratings shown are for elevations up to 2,000 feet; for elevations above 2,000 feet, consult the manufacturer. Any manufacturer who wishes to submit his boiler for testing and approval under the testing standard may do so, upon payment of applicable fees, regardless of whether they are a member of AHRI. Data shown in this book is only for those manufacturers who elected to participate in AHRI’s rating and licensing program. An alphabetical index is provided at the back of this book of all boiler, baseboard, finned tube, and indirect-fired water heater manufacturers who have current I=B=R ratings for their products. Every effort has been made to assure the accuracy of the data contained in this book and in the other publications issued by AHRI. However, neither AHRI nor those responsible for the preparation of the association’s publications make any representation or guarantee, or assume or accept any responsibility or liability with respect thereto. Use of the I=B=R Emblem The I=B=R emblem is the property of AHRI, registered in its name at the United States Patent and Trademark Office, and the Registrar of Trademarks in Canada. All boilers listed in this book must bear the I=B=R emblem on the manufacturer’s nameplate affixed to the boiler. The emblem is to be used only on the specific models whose ratings have been approved by AHRI. The use of the emblem in

Page 3: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

APR 2009 - 2

manufacturers’ literature is limited to those pages or those publications which are entirely devoted to products qualified to display the emblem. No one has permission to state that his product has been tested under the I=B=R Certification Program, or to publish I=B=R Ratings, or to use the I=B=R Emblem in any manner, unless

(a) The manufacturer has executed a license with AHRI, and (b) AHRI has tested the series according to the I=B=R Procedural Guide for Heating Boilers, or GAMA’s I=B=R

Procedural Guide for Indirect-Fired Water Heaters and (c) AHRI has advised the manufacturer in writing of the exact rating applicable to the specific models.

All I=B=R Rated boilers must be manufactured in accordance with the latest edition of Section IV of the ASME Boiler and Pressure Vessel Code covering Heating Boilers.

Why Hydronics Besides the reliability of equipment ratings, and the well-established reliability of hydronic accessories, there are many good reasons why hydronic systems have long been recognized as the standard method for providing indoor comfort. Hydronic heating, whether steam or hot water, provides positive, controlled circulation of the heating medium. Systems are basically self-balancing, and in larger, more complicated heating systems, balancing is positively controlled by familiar valves and thermostats. The life of hydronic equipment is measured in decades; some existing boilers are more than fifty years old. In addition to the high efficiency of boilers (some over 90%), losses through the distribution system are extremely low on modern installations. Temperature control is close to ideal with hydronics. Any well-designed system can provide excellent comfort, without drafts or sharp swings in temperature. The flexibility of hydronic installations permits a variety of piping arrangements, simple or sophisticated controls, and large choice of room distribution units for all comfort applications.

Historical Timeline

1915: National Boiler and Radiation Manufacturers Association is formed by producers of cast iron boilers and radiators. 1929: The name is changed to the Institute of Boiler and Radiator Manufacturers (I=B=R). 1940: Start of 30-year research agreement with the University of Illinois, including 39 research programs which resulted

in many improvements of systems and equipment 1944: Institute broadened to include manufacturers of non-ferrous radiation, and accessories for systems and equipment. 1956: I=B=R Test Laboratory built at Urbana, Illinois and manned by engineers of the University of Illinois. 1963: Manufacturers of Steel heating boilers join to become the Steel Boiler Division. 1970: The Hydronics Institute is formed from the above predecessors. 1983: Burner and Burner Components Division is formed as an operating group within The Institute. 1995: The Hydronics Institute became a Division of GAMA. 2008: GAMA and ARI merged to become the Air-Conditioning, Heating, and Refrigeration Institute.

Testing and Rating Procedures for Boilers The current edition of the "Procedural Guide for I=B=R Boiler Ratings Certification Program" details the basis for determining I=B=R Ratings and itemizes specific methods and procedures to assure accuracy and uniformity of testing. A brief outline of standard practices is provided below. The tests determine the Ratings in terms of “Heating Capacity” or “Gross Output”, the former referring to boilers under 300,000 Btuh input, and the latter to larger sizes. The size distinction is based on the Department of Energy’s test procedure for small boilers, published in the Federal Register of May 12, 1997 and ASHRAE Standard 103-1993. Under the DOE regulations, manufacturers are responsible for testing to determine the efficiency ratings of residential boilers and reporting the ratings to the Federal Trade Commission. AHRI conducts one qualification test on each series to assure the

Page 4: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

APR 2009 - 3

accuracy of the manufacturer’s testing. Then annually, AHRI conducts certification tests on samples randomly selected from the manufacturer’s stock to assure the continued accuracy of the ratings. The number of tests conducted is related to the number of models listed for the manufacturer. All tests are conducted by a representative of AHRI’s Certification Services at the manufacturer’s laboratory or the Program's designated testing agency. The boiler models listed herein which have been tested by The Program have met the following conditions:

Draft and CO2 Settings: As recommended by the manufacturer for that series. Minimum Efficiencies: Small (DOE) boilers – (AFUE of 80%, except gas steam boilers, which are 75% AFUE).

Large boilers – Combustion Efficiency of 80%. Smoke in Flue Gas: Not more than #1 smoke for light oil, or #4 smoke for heavy oil.

Annual Fuel Utilization Efficiency (AFUE): In the qualification test, the test sample must achieve at least 98% of the listed AFUE value. In the annual certification test, the test sample must achieve at least 95% of the listed AFUE value.

Oil-fired inputs are based on nominal heating values of 140,000 Btu per gallon unless the boiler is specifically rated for heavy oil with a nominal heating value of 150,000 Btu per gallon. Gas inputs are expressed in MBh (thousands of Btu/hour).

Definitions ANNUAL FUEL UTILIZATION EFFICIENCY (AFUE): Applicable to DOE boilers under 300,000 Btuh input, 100%

minus the losses up the stack during the ON and OFF cycles and the losses due to infiltration of outside air to replace air used for combustion and draft control.

ANSI-Z21.13 OUTPUT: the certified boiler output derived from tests conducted in accordance with ANSI-Z21.13 test procedure.

BRITISH THERMAL UNITS: Btu’s COMBUSTION EFFICIENCY (Comb Effy): 100 percent minus the percent of flue loss. COMMERCIAL BOILER: a boiler whose input is 300,000 Btuh (British Thermal Units per hour) or more. DAMPER: an electro-mechanical device installed after the draft relief device and closes during the off cycle. FLUE DAMPER: an electro-mechanical device installed before the draft relief device that closes during the off cycle. FORCED DRAFT: systems in which combustion air is blown into the combustion chamber and maintained at a positive

pressure. GROSS OUTPUT (for larger boilers): the total quantity of Btu’s which the boiler will deliver in the form of heated water

output or steam output per hour, and at the same time meet all the test requirements set forth in the standard.

HEATING CAPACITY (Heat Cap.) (less than 300,000 input): the rate of useful heat output from a boiler operating under steady state conditions, expressed in Btu/hr, and rounded to the near 1,000 Btu/hr, as defined by DOE. “Useful heat” includes jacket losses given up to the building. Heating Capacity is determined by multiplying the specified input by the steady state efficiency, as tested.

INDUCED DRAFT: a system which uses a blower to draw air into the combustion chamber. MBh: thousands of Btu’s (British Thermal Units) per hour. NET I=B=R RATING: the recommended amount of installed radiation to be served by the boiler, based on the normal

allowance for piping and pickup losses.* Net Ratings for water system boilers [Water (MBh)] are determined by dividing steady state test results by a factor of 1.15. To obtain Net Ratings for steam boilers [Steam (sqft), Steam (MBh)], test results are divided by a varying factor** to provide for varying piping and pickup losses in larger steam systems.

THERMAL EFFICIENCY (Thermal Effy) (for larger boilers): measured gross output of the boiler divided by the measured heat input to the boiler, under steady state conditions.

RESIDENTIAL BOILER: a boiler whose input is less than 300,000 Btuh (British Thermal Units per hour.) STEADY STATE EFFICIENCY (DOE): 100% minus the sensible and latent losses up the flue when operating at steady

state conditions.

Page 5: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

APR 2009 - 4

* The manufacturer should be consulted before selecting a boiler for installation on a job having unusual piping and pickup requirements. It is essential that the advice of the manufacturer of the boiler be solicited before selecting a boiler for replacement on an existing installation which has a larger amount of piping than would normally be installed, or where other unusual conditions exist, such as intermittent operation, temperature conditions other than normal, and unbalanced systems.

** Up to 1,254 MBh rating: by 1.333; 1,256 to 1,936 MBh: decreasing factors down to 1.288; Above 1,936 MBh: by 1.288

BOILER HEADING ABBREVIATIONS Comb Effy (%) = Combustion Efficiency, percent Chim Hgt (ft) = Chimney Height, feet Oil (gph) = Oil input, gallons per hour Steam (sqft) = Steam Square Feet, 240 Btuh/Square Feet Steam (MBh) = Steam, thousands of Btu’s per hour Thermal Effy (%) = Thermal Efficiency, percent Vent Size (LxWxH) = inches x inches x feet Water (MBh) = Water, thousands of Btu/hour Heat Cap. (MBh) = Heating Capacity, thousands of Btu/hour MINIMUM STACK AREAS FOR OIL-FIRED NATURAL DRAFT RESIDENTIAL BOILERS RECTANGULAR ROUND Burner Nominal Burner Inside Diameter Capacity Stack Sizes Capacity of Liner not Over (inches) not Over (inches)

2.1 gal/hr 8 x 8 1.3 gal/hr 6 3.5 gal/hr 8 x 12 1.8 gal/hr 7 2.5 gal/hr 8

FORCED DRAFT RESIDENTIAL BOILERS D.O.E. Heating Minimum Vent Capacity – MBh Diameter - Inches

Up to 132..................................................................... 4 133 – 198..................................................................... 5 199 – 324..................................................................... 6 Boiler Testing The widespread prevalence of I=B=R Ratings has virtually eliminated the “credibility’ problem which existed around the turn of the 20th century, when there were no national standards. Each manufacturer assigned its own Btu output to their products; ethical producers assigned conservative ratings while others exaggerated to help sell boilers. That was the state of the market when the predecessor of the Institute of Boiler and Radiator Manufacturers (I=B=R) was founded in 1915. The I=B=R Rating Procedure for Heating Boilers has the following basic requirements in order for a model to be certified and licensed by AHRI. Every boiler must meet ASME standards for construction and for safety devices. Every commercial boiler must meet a minimum steady state efficiency of 75%, although most are much higher. Every residential boiler must meet a minimum of 80% AFUE except natural gas steam, which must meet at least 75% AFUE. Steady State efficiency tests for commercial and residential boilers are essentially the same. However, in 1978, the U.S. Department of Energy mandated that residential boilers up to 300,000 Btuh input are to have an additional test for Annual Fuel Utilization Efficiency (AFUE) as a guide for homeowners to ascertain the relative efficiencies of various brands. The added test includes a “heat-up” and “cool-down” cycling test which provides an estimate of the annual cost of operation. Besides tests on new models, certification tests are performed on existing models on a planned cycle, annually for residential boilers, and five years for commercial sizes, as long as that model is being offered on the market. This is truly an all-encompassing program to ensure that the boiler will provide the amount of heat specified. Unless otherwise noted, the commercial boilers in this book have been tested in accordance with test procedures specified in the BTS-2000 Testing Standard for Commercial Space Heating Boilers.

© Copyright 2009 Air-Conditioning, Heating, and Refrigeration Institute

Page 6: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

AERCO INTERNATIONAL, INC.

ALUMINUM

#MODULEX Modulating, Condensing, Pressure Fired, Inter. Ign., Natural or Propane Gas

MLX303 279 4" Dia. 303 24392.0MLX454 418 4" Dia. 454 36392.0MLX606 558 4" Dia. 606 48592.0MLX757 696 6" Dia. 757 60592.0MLX909 835 6" Dia. 909 72692.0MLX1060 975 6" Dia. 1060 84892.0Ratings based on 9.0% CO2 and 0" water draft.

STAINLESS STEEL

Benchmark Low NOx Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural Gas

BMK1.5LN 1379 6" Dia. 1500 119991.993.9Ratings based on 9.7% CO2 and +0.001" water draft at the vent.

Benchmark Low NOx Series Modulating, Condensing, Forced Draft, Inter. Ign., Natural Gas

BMK 2.0 LN 1846 8" Dia. 2000 160591.092.3BMK 3.0 LN 2856 8" Dia. 3000 248393.995.2

BIASI, S.p.A.c/o QHT, INC.

CAST IRON

B40 Series Forced Draft, Light Oil

B40-7 301 2622.50 86.087.8B40-8 365 3173.00 86.988.1B40-9 429 3733.50 87.688.4B40-10 493 4294.00 88.088.6B40-11 557 4844.50 88.488.7B40-12 622 5415.0 88.888.7Ratings based on 13.2% CO2 and -0.02" water draft at the vent.

SG Series Forced Draft, Light Oil

SG-7 272 2372.25 86.286.6Ratings based on 13.0% CO2 and -0.02" water draft at the vent.

BUDERUS-BOSCH THERMOTECHNOLOGY CORP

ALUMINUM

GB162 Power Burner, Modulating, Condensing, Pressure Fired, Inter. Ign., Natural Gas

GB162-100 298 6" Dia. 333 25989.489.2Ratings based on 9.3% CO2 and 0" water draft.

Power Burner, Modulating, Condensing, Pressure Fired, Inter. Ign., Propane GasGB162-100 282 6" Dia. 315 24589.489.2Ratings based on 9.3% CO2 and 0" water draft.

GB312 Modulating, Condensing, Induced Draft, Inter. Ign., Natural Gas

GB312 - 90 305 5" Dia. 328 26593.193.4GB312 - 120 409 6" Dia. 441 35692.893.1GB312 - 160 544 6" Dia. 588 47392.592.8GB312 - 200 676 8" Dia. 733 58892.392.5GB312 - 240 810 8" Dia. 881 70492.092.2GB312 - 280 944 8" Dia. 1029 82191.792.0

CAST IRON

G215 Series Natural Draft, Light Oil

G215-7 294 8x12x15 2562.50 83.986.7Ratings based on 13.0% CO2 and -0.005" water draft.

G315 Series Natural Draft, Light Oil

G315-5 350 8x12x15 3043.00 83.386.8G315-6 454 12x12x15 3953.85 84.386.9G315-7 559 12x12x15 4864.7 84.987.0G315-8 663 12x16x15 5775.6 85.487.1G315-9 768 12x16x15 6686.4 85.787.1Ratings based on 13.0% CO2 and -0.02" water draft.

Power Burner, Natural Draft, Inter. Ign., Natural GasG315-5 350 8x12x15 433 30480.884.2G315-6 454 12x12x15 556 39581.884.3G315-7 559 12x12x15 678 48682.484.4G315-8 663 12x16x15 801 57782.884.4G315-9 768 12x16x15 924 66883.184.5Ratings based on 10.0% CO2 and -0.02" water draft.

#G334X Series Atmospheric, Inter. Ign., Natural or Propane Gas

G334X-73 249 301 21782.7G334X-92 314 378 27383.1G334X-116 396 476 34483.2G334X-132 451 542 39283.2

G515 Series Natural Draft, Light Oil

G515-7 818 12x16x15 7116.9 84.888.2G515-8 1009 16x16x15 8778.4 85.588.2G515-9 1201 16x16x15 104410.0 86.188.1G515-10 1392 16x20x15 121011.6 86.488.1G515-11 1583 16x20x15 137713.0 86.888.1G515-12 1775 16x20x15 154314.6 87.088.1Ratings based on 13.0% CO2 and -0.02" water draft.

Power Burner, Natural Draft, Inter. Ign., Natural GasG515-7 818 12x16x15 995 71182.285.6G515-8 1009 16x16x15 1216 87783.085.5G515-9 1201 16x16x15 1438 104483.585.5G515-10 1392 16x20x15 1660 121083.985.5G515-11 1583 16x20x15 1881 137784.285.4G515-12 1775 16x20x15 2103 154384.485.4Ratings based on 10.0% CO2.

G615 Series Forced Draft, Light Oil

G615-9 1951 14" Dia. 169716.0 87.186.7G615-10 2242 14" Dia. 195018.5 86.586.7G615-11 2532 14" Dia. 220221.0 86.186.6G615-12 2822 16" Dia. 245423.5 85.886.6G615-13 3112 16" Dia. 270626.0 85.586.5G615-14 3402 18" Dia. 295828.5 85.386.5G615-15 3692 18" Dia. 321031.0 85.186.5G615-16 3982 18" Dia. 346333.5 84.986.5Ratings based on 13.0% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Inter. Ign., Natural GasG615-9 1951 14" Dia. 2309 169784.584.1G615-10 2242 14" Dia. 2670 195083.984.1G615-11 2532 14" Dia. 3031 220283.584.0G615-12 2822 16" Dia. 3392 245483.284.0G615-13 3112 16" Dia. 3753 270682.983.9G615-14 3402 18" Dia. 4113 295882.783.9G615-15 3692 18" Dia. 4474 321082.583.9G615-16 3982 18" Dia. 4835 346382.483.9Ratings based on 10.0% CO2 and +0.10" water draft at the vent.

STEEL

SB315 Series Power Burner, Condensing, Forced Draft, Inter. Ign., Natural or Propane Gas

APR 2009 - 36# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 7: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

BUDERUS-BOSCH THERMOTECHNOLOGY CORP

STEEL

SB315 Series Power Burner, Condensing, Forced Draft, Inter. Ign., Natural or Propane Gas

SB-315-90 302 313 26396.496.6SB-315-115 385 399 33596.496.6

SB615 Series Power Burner, Condensing, Forced Draft, Inter. Ign., Natural or Propane Gas

SB-615-145 484 506 42195.697.1SB-615-185 612 644 53295.096.7SB-615-240 791 835 68894.896.5SB-615-310 1022 1080 88994.696.4SB-615-400 1317 1393 114594.596.3SB-615-510 1678 1776 145994.596.2SB-615-640 2104 2228 183094.496.2

SB735 Series Power Burner, Condensing, Forced Draft, Inter. Ign., Natural or Propane Gas

SB-735-790 2611 2751 227096.994.8SB-735-970 3257 3378 283296.195.6SB-735-1200 4082 4179 355097.596.5

BURNHAM COMMERCIAL

CAST IRON

#8H SERIES Atmospheric, Inter. Ign., Natural or Propane Gas

806H 262 315 22880.283.1807H 311 374 27080.083.2808H 360 433 31379.983.3809H 409 491 35679.883.4810H 459 550 39979.783.4

MPC Power Burner, Forced Draft, Inter. Ign., Natural Gas

MPC-4 424 8" Dia. 500 36984.786.3MPC-5 652 8" Dia. 773 56784.386.1MPC-6 837 10" Dia. 996 72884.186.0MPC-7 1023 10" Dia. 1216 89084.186.0MPC-8 1209 10" Dia. 1438 105184.185.9MPC-9 1395 12" Dia. 1660 121384.085.9MPC-10 1580 12" Dia. 1881 137484.085.9MPC-11 1766 12" Dia. 2103 153684.085.9MPC-12 1951 14" Dia. 2325 169783.985.8MPC-13 2137 14" Dia. 2547 185883.985.8MPC-14 2322 14" Dia. 2769 201983.985.8MPC-15 2508 14" Dia. 2991 218183.885.8MPC-16 2694 14" Dia. 3213 234383.885.8MPC-17 2880 14" Dia. 3435 250483.885.8MPC-18 3065 14" Dia. 3657 266583.885.8Ratings based on 10.0% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Light OilMPC-4 424 8" Dia. 3693.55 87.389.0MPC-5 652 8" Dia. 5675.5 86.988.8MPC-6 837 10" Dia. 7287.1 86.888.7MPC-7 1023 10" Dia. 8908.7 86.788.7MPC-8 1209 10" Dia. 105110.2 86.788.6MPC-9 1395 12" Dia. 121311.8 86.688.6MPC-10 1580 12" Dia. 137413.4 86.688.6MPC-11 1766 12" Dia. 153615.0 86.688.5MPC-12 1951 14" Dia. 169716.6 86.588.5MPC-13 2137 14" Dia. 185818.2 86.588.5MPC-14 2322 14" Dia. 201919.8 86.588.5MPC-15 2508 14" Dia. 218121.4 86.588.4MPC-16 2694 14" Dia. 234323.0 86.488.4

MPC-17 2880 14" Dia. 250424.6 86.488.4MPC-18 3065 14" Dia. 266526.2 86.488.4Ratings based on 13.2% CO2 and +0.10" water draft at the vent.

#Series 5 Atmospheric, Inter. Ign., Propane Gas

K5006 301 376 942 262 22677.080.0K5007 351 439 1096 305 26377.080.0K5008 410 512 1279 356 30777.080.0K5009 468 585 1463 407 35177.080.0K5010 527 658 1646 458 39577.080.0K5011 585 731 1829 509 43977.080.0K5012 644 804 2013 560 48377.080.0K5013 702 878 2196 610 52777.080.0K5014 761 951 2379 661 57177.080.0K5015 819 1024 2558 712 61477.080.0K5016 878 1097 2742 763 65877.080.0K5017 936 1170 2925 814 70277.080.0K5018 995 1243 3108 865 74677.080.0K5019 1053 1316 3292 916 79077.080.0K5020 1112 1389 3475 967 83477.080.0K5021 1170 1463 3658 1017 87877.080.0K5022 1229 1536 3842 1068 92277.080.0K5024 1346 1682 4233 1170 101677.080.0K5026 1463 1828 4642 1272 111477.080.0

Atmospheric, Standing Pilot, Natural GasK5006 321 401 1004 279 24177.080.0K5007 375 468 1171 326 28177.080.0K5008 437 546 1367 380 32877.080.0K5009 500 624 1558 434 37477.080.0K5010 562 702 1754 488 42177.080.0K5011 624 780 1950 543 46877.080.0K5012 687 858 2146 597 51577.080.0K5013 749 936 2342 651 56277.080.0K5014 812 1014 2538 705 60977.080.0K5015 874 1092 2729 760 65577.080.0K5016 936 1170 2925 814 70277.080.0K5017 999 1248 3121 868 74977.080.0K5018 1061 1326 3317 922 79677.080.0K5019 1124 1404 3513 977 84377.080.0K5020 1186 1482 3704 1031 88977.080.0K5021 1248 1560 3900 1085 93677.080.0K5022 1311 1638 4113 1139 98777.080.0K5024 1436 1794 4546 1248 109177.080.0K5026 1560 1950 4975 1357 119477.080.0

V11 Series Power Burner, Forced Draft, Inter. Ign., Natural Gas

V1104 667 8" Dia. 837 2083 580 50079.782.8V1105 857 8" Dia. 1068 2679 745 64380.282.6V1106 1069 8" Dia. 1328 3342 930 80280.482.5V1107 1281 10" Dia. 1588 4013 1114 96380.782.4V1108 1517 10" Dia. 1876 4829 1319 115980.882.3V1109 1729 10" Dia. 2136 5563 1503 133580.982.3V1110 1941 12" Dia. 2396 6279 1688 150781.082.2V1111 2154 12" Dia. 2656 6967 1873 167281.182.2V1112 2334 12" Dia. 2887 7550 2030 181280.982.1V1113 2503 12" Dia. 3103 8096 2177 194380.782.0V1114 2730 14" Dia. 3392 8833 2374 212080.481.9V1115 2957 14" Dia. 3680 9567 2571 229680.381.8V1116 3129 14" Dia. 3897 10113 2718 242780.281.7V1117 3353 14" Dia. 4186 10846 2916 260380.181.7V1118 3580 16" Dia. 4474 11583 3113 278080.081.6V1119 3739 16" Dia. 4691 12096 3251 290379.781.4V1120 3957 16" Dia. 4979 12800 3441 307279.581.2V1121 4174 16" Dia. 5268 13504 3630 324179.281.0V1122 4334 18" Dia. 5485 14021 3769 336579.180.8V1123 4551 18" Dia. 5733 14721 3957 353378.880.7Ratings based on 10.0% CO2 and +0.10" water draft at the vent.

APR 2009 - 37# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 8: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

BURNHAM COMMERCIAL

CAST IRON

V11 Series Power Burner, Forced Draft, Light Oil

V1104 667 8" Dia. 2083 580 5005.8 82.285.3V1105 857 8" Dia. 2679 745 6437.4 82.785.1V1106 1069 8" Dia. 3342 930 8029.2 83.085.0V1107 1281 10" Dia. 4013 1114 96311.0 83.284.9V1108 1517 10" Dia. 4829 1319 115913.0 83.384.9V1109 1729 10" Dia. 5563 1503 133514.8 83.484.8V1110 1941 12" Dia. 6279 1688 150716.6 83.584.8V1111 2154 12" Dia. 6967 1873 167218.4 83.684.8V1112 2334 12" Dia. 7550 2030 181220.0 83.484.6V1113 2503 12" Dia. 8096 2177 194321.5 83.184.5V1114 2730 14" Dia. 8833 2374 212023.5 83.084.4V1115 2957 14" Dia. 9567 2571 229625.5 82.884.3V1116 3129 14" Dia. 10113 2718 242727.0 82.784.3V1117 3353 14" Dia. 10846 2916 260329.0 82.684.2V1118 3580 16" Dia. 11583 3113 278031.0 82.584.1V1119 3739 16" Dia. 12096 3251 290332.5 82.283.9V1120 3957 16" Dia. 12800 3441 307234.5 81.983.7V1121 4174 16" Dia. 13504 3630 324136.5 81.783.5V1122 4334 18" Dia. 14021 3769 336538.0 81.583.3V1123 4551 18" Dia. 14721 3957 353340.0 81.383.2Ratings based on 13.0% CO2 and +0.10" water draft at the vent.

V9A Series Power Burner, Forced Draft, Inter. Ign., Natural Gas

V903 358 7" Dia. 447 1121 311 26980.082.5V904 485 7" Dia. 606 1517 422 36480.182.5V905 647 8" Dia. 808 2021 563 48580.182.4V906 809 8" Dia. 1010 2529 703 60780.182.4V907 960 8" Dia. 1198 3000 835 72080.182.3V908 1112 10" Dia. 1386 3475 967 83480.282.3V909 1343 10" Dia. 1674 4225 1168 101480.282.6V910 1528 10" Dia. 1905 4867 1329 116880.282.2V911 1714 12" Dia. 2136 5513 1490 132380.382.1V912 1900 12" Dia. 2367 6142 1652 147480.382.1Ratings based on 9.7% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Light OilV903 347 7" Dia. 1083 302 2603.10 80.085.2V904 483 7" Dia. 1508 420 3624.20 82.186.0V905 646 8" Dia. 2021 562 4855.6 82.485.5V906 808 8" Dia. 2525 703 6067.0 82.585.2V907 959 8" Dia. 2996 834 7198.3 82.685.1V908 1110 10" Dia. 3471 965 8339.6 82.684.9V909 1342 10" Dia. 4225 1167 101411.6 82.784.8V910 1528 10" Dia. 4867 1329 116813.2 82.784.8V911 1714 12" Dia. 5513 1490 132314.8 82.784.7V912 1900 12" Dia. 6142 1652 147416.4 82.784.7Ratings based on 12.5% CO2 and +0.10" water draft at the vent.

BURNHAM HYDRONICS (U.S. BOILER CO., INC.)

CAST IRON

#Independence Atmospheric, Standing Pilot, Natural Gas

IN10 260 315 812 19579.582.5IN10 264 315 22680.583.5IN11 288 349 900 21679.582.5IN11 292 349 25080.583.5IN12 318 385 996 23979.582.5IN12 342 385 27680.583.5

V8 Series Power Burner, Natural Draft, Light Oil

V88S 266 8x12x15 833 2002.35 81.484.2

V88W 275 8x12x15 2392.35 81.484.2V89S 298 8x12x15 933 2242.60 82.384.1V89W 299 8x12x15 2602.60 82.384.1Ratings based on 13.0% CO2 and -0.02" water draft.

STAINLESS STEEL

Alpine Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural or

Propane GasALP399 376 4" Dia. 399 32794.194.5Ratings based on 9.0% CO2 and +0.01" water draft at the vent.

STEEL

Opus O1 Power Burner, Natural Draft, Light Oil

O1-3-225 267 8x12x15 2322.25 84.986.5Ratings based on 13.5% CO2.

RSA Series Power Burner, Natural Draft, Light Oil

RSA240 268 8x12x20 2332.40 79.384.2RSA285 318 8x12x20 2772.85 79.283.2Ratings based on 12.5% CO2 and -0.02" water draft.

COLUMBIA BOILER COMPANY OF POTTSTOWN

STEEL

WB Five Star Series Forced Draft, Light Oil

WB-225 264 2302.25 83.785.6WB-250 291 2532.50 83.485.2WB-275 319 2772.75 82.984.9Ratings based on 13.2% CO2 and -0.02" water draft at the vent.

CROWN BOILER CO.

CAST IRON

#32 Series Atmospheric, Inter. Ign., Natural or Propane Gas

32-475*N 380 475 1188 330 28575.480.532-570*N 456 570 1425 397 34275.480.532-665*N 532 665 1663 463 39975.480.532-760*N 608 760 1900 529 45675.480.532-855*N 684 855 2138 595 51375.480.532-950*N 760 950 2375 661 57075.480.532-1045*N 836 1045 2613 727 62775.480.532-1140*N 912 1140 2850 793 68475.480.532-1235*N 988 1235 3088 859 74175.480.532-1330*N 1064 1330 3325 925 79875.480.532-1425*N 1140 1425 3563 991 85575.480.532-1520*N 1216 1520 3801 1057 91275.480.532-1615*N 1292 1615 4050 1123 97275.480.532-1710*N 1368 1710 4313 1190 103575.480.532-1805*N 1444 1805 4575 1256 109875.480.532-1900*N 1520 1900 4838 1322 116175.480.532-1995*N 1596 1995 5104 1388 122575.480.532-2090*N 1672 2090 5367 1454 128875.480.532-2185*N 1748 2185 5629 1520 135175.480.532-2280*N 1824 2280 5892 1586 141475.480.532-2375*N 1900 2375 6142 1652 147475.480.532-2470*N 1976 2470 6392 1718 153475.480.532-2565*N 2052 2565 6638 1784 159375.480.532-2660*N 2128 2660 6883 1850 165275.480.532-2755*N 2204 2755 7129 1917 171175.480.532-2850*N 2280 2850 7375 1983 177075.480.5

#Bermuda Series Atmospheric, Inter. Ign., Natural or Propane Gas

APR 2009 - 38# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 9: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

CROWN BOILER CO.

CAST IRON

#Bermuda Series Atmospheric, Inter. Ign., Natural or Propane Gas

BSI310E 253 310 791 220 19081.5BSI345E 282 345 881 245 21281.6BSI379E 309 379 966 269 23281.6

Atmospheric, Standing Pilot, Natural or Propane GasBSI310S 253 310 791 220 19081.5BSI345S 282 345 881 245 21281.6BSI379S 309 379 966 269 23281.6

#Cayman Series Atmospheric, Inter. Ign., Natural or Propane Gas

CWI310E 255 310 22282.4CWI345E 284 345 24782.3CWI379E 312 379 27182.2

Atmospheric, Standing Pilot, Natural or Propane GasCWI310S 255 310 22282.4CWI345S 284 345 24782.3CWI379S 312 379 27182.2Natural Gas only

F Series Power Burner, Forced Draft, Inter. Ign., Natural Gas

F4 355 7" Dia. 433 30981.782.5F5 478 7" Dia. 577 41682.782.5F6 600 8" Dia. 722 52283.282.4F7 723 9" Dia. 866 62983.582.4F8 907 10" Dia. 1082 78983.882.3F9 1091 10" Dia. 1299 94984.082.2Ratings based on 9.7% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Light OilF4 355 7" Dia. 3093.00 84.585.0F5 478 7" Dia. 4164.00 85.385.0F6 600 8" Dia. 5225.0 85.884.9F7 723 9" Dia. 6296.0 86.184.9F8 907 10" Dia. 7897.5 86.484.8F9 1091 10" Dia. 9499.0 86.684.7Ratings based on 12.5% CO2 and +0.10" water draft at the vent.

Freeport Series Power Burner, Forced Draft, Light Oil

CT-8 286 8x12x15 2492.50 81.785.3Ratings based on 13.0% CO2 and -0.02" water draft at the vent.

#Jamaica III Atmospheric, Inter. Ign., Natural Gas

JSE310E 245 310 767 18477.080.0JSE345E 273 345 854 20577.080.0JSE379E 299 379 933 22477.080.0

Atmospheric, Standing Pilot, Natural GasJSE310S 245 310 767 18477.080.0JSE345S 273 345 854 20577.080.0JSE379S 299 379 933 22477.080.0

#Series 16 Atmospheric, Inter. Ign., Natural or Propane Gas

16-325 260 325 22677.080.016-390 312 390 27177.080.016-455 364 455 31777.080.016-520 416 520 36277.080.016-585 468 585 40777.080.0

Series 24 Forced Draft, Inter. Ign., Natural or Propane Gas

24-03 350 7" Dia. 438 1096 304 26380.082.5Ratings based on 9.7% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Inter. Ign., Natural or Propane Gas24-04 476 7" Dia. 594 1488 414 35780.182.524-05 634 8" Dia. 792 1983 551 47680.182.424-06 793 8" Dia. 990 2479 690 59580.182.424-07 940 8" Dia. 1174 2938 817 70580.182.324-08 1089 10" Dia. 1358 3404 947 81780.282.324-09 1316 10" Dia. 1641 4133 1144 99280.282.324-10 1497 10" Dia. 1867 4758 1302 114280.282.224-11 1681 12" Dia. 2093 5396 1462 129580.382.124-12 1863 12" Dia. 2320 6017 1617 144480.382.1Ratings based on 9.7% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Light Oil24-03 342 7" Dia. 1071 297 2573.05 80.085.224-04 471 7" Dia. 1471 410 3534.10 82.186.024-05 634 8" Dia. 1983 551 4765.5 82.485.524-06 797 8" Dia. 2492 693 5986.9 82.585.224-07 937 8" Dia. 2929 815 7038.1 82.685.124-08 1087 10" Dia. 3396 945 8159.4 82.684.924-09 1316 10" Dia. 4146 1148 99511.4 82.784.824-10 1505 10" Dia. 4788 1309 114913.0 82.784.824-11 1690 12" Dia. 5429 1470 130314.6 82.784.724-12 1852 12" Dia. 5983 1610 143616.0 82.784.7Ratings based on 12.5% CO2 and +0.10" water draft at the vent.

DUNKIRK BOILERS, ECR INTERNATIONAL, INC.

CAST IRON

#Series D247 Atmospheric, Inter. Ign., Natural Gas

D247-300 240 300 750 209 18080.0D247-400 320 400 1000 278 24080.0D247-500 400 500 1250 348 30080.0D247-600 480 600 1500 417 36080.0D247-700 560 700 1750 487 42080.0D247-800 640 800 2000 557 48080.0D247-900 720 900 2250 626 54080.0D247-1000 800 1000 2500 696 60080.0D247-1100 880 1100 2750 765 66080.0D247-1200 960 1200 3000 835 72080.0D247-1300 1040 1300 3250 904 78080.0D247-1400 1120 1400 3500 974 84080.0D247-1500 1200 1500 3750 1043 90080.0D247-1600 1280 1600 4008 1113 96280.0D247-1700 1360 1700 4283 1183 102880.0D247-1800 1440 1800 4563 1252 109580.0D247-1900 1520 1900 4838 1322 116180.0D247-2000 1600 2000 5117 1391 122880.0D247-2100 1680 2100 5392 1461 129480.0D247-2200 1760 2200 5671 1530 136180.0D247-2300 1840 2300 5942 1600 142680.0D247-2400 1920 2400 6213 1670 149180.0D247-2500 2000 2500 6471 1739 155380.0D247-2600 2080 2600 6729 1809 161580.0D247-2700 2160 2700 6988 1878 167780.0D247-2800 2240 2800 7246 1948 173980.0D247-2900 2320 2900 7504 2017 180180.0D247-3000 2400 3000 7763 2087 186380.0Also approved with suffix S or W.

HEAT TRANSFER PRODUCTS INC.

STAINLESS STEEL

Mod Con Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural or

Propane GasMod Con 300 283 4" Dia. 301 24694.094.0Mod Con 500 470 4" Dia. 500 40994.094.0

APR 2009 - 39# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 10: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

HEAT TRANSFER PRODUCTS INC.

STAINLESS STEEL

Mod Con Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural or

Propane GasMod Con 850 799 6" Dia. 850 69594.094.0Ratings based on 9.5% CO2 and -0.01" water draft at the vent.

Munchkin 399M Series Power Burner, Direct Vent, Condensing, Induced Draft, Inter. Ign., Natural or

Propane Gas399M 379 399 33093.495.1399VWH 379 399 33093.495.1

LAARS HEATING SYSTEMS COMPANY

COPPER

#MightyTherm Series C Atmospheric, Inter. Ign., Natural or Propane Gas

HH325 264 325 22981.0HH400 324 400 28281.0

Outdoor, Atmospheric, Inter. Ign., Natural GasHH0400C 333 400 29083.4Indoor/Outdoor

Outdoor, Atmospheric, Inter. Ign., Natural or Propane GasHH325 260 325 22680.0HH400 320 400 27880.0

#MightyTherm Series E Outdoor, Atmospheric, Inter. Ign., Natural or Propane Gas

HH0500 410 500 35782.0HH0600 492 600 42882.0HH0715 587 715 51082.0HH0850 697 850 60682.0HH0999 820 999 71282.0HH1010 829 1010 72082.0HH1200 984 1200 85682.0HH1430 1173 1430 102082.0HH1670 1370 1670 119182.0HH1825 1497 1825 130182.0HH2200 1787 2205 155381.0HH2800 2224 2745 199381.0HH3200 2552 3150 221981.0HH3600 2953 3645 256781.0HH4000 3281 4050 285381.0HH4500 3645 4500 317081.0

#MightyTherm Series I Atmospheric, Inter. Ign., Natural or Propane Gas

HH0500 405 500 35281.0HH0600 486 600 42381.0HH0715 580 715 50481.0HH0850 689 850 59981.0HH0999 810 999 70481.0HH1010 819 1010 71181.0HH1200 972 1200 84581.0HH1430 1159 1430 100781.0HH1670 1353 1670 117681.0HH1825 1479 1825 128581.0HH2000 1640 2000 142682.0HH2450 2009 2450 174782.0HH3050 2501 3050 217582.0HH3500 2870 3500 249682.0HH4050 3321 4050 288882.0HH4500 3690 4500 320982.0HH5000 4100 5000 356582.0

LOCHINVAR CORPORATION

COPPER

#Copper-Fin Power Burner, Two-Stage, Forced Draft, Inter. Ign., Natural Gas

CBN495 401 6" Dia. 495 34981.082.0CBN645 522 8" Dia. 645 45481.082.0CBN745 603 8" Dia. 745 52481.082.0CBN0986 798 10" Dia. 985 69481.082.0CBN1256 1017 12" Dia. 1255 88481.082.0CBN1436 1162 12" Dia. 1435 101081.082.0CBN1796 1454 14" Dia. 1795 126481.082.0CBN2066 1673 14" Dia. 2065 145581.082.0Ratings based on 8.3% CO2 and -0.04" water draft at the vent.

Power Burner, Two-Stage, Forced Draft, Inter. Ign., Propane GasCBL495 401 6" Dia. 495 34981.082.0CBL645 522 8" Dia. 645 45481.082.0CBL745 603 8" Dia. 745 52481.082.0CBL0986 798 10" Dia. 985 69481.082.0CBL1256 1017 12" Dia. 1255 88481.082.0CBL1436 1162 12" Dia. 1435 101081.082.0CBL1796 1454 14" Dia. 1795 126481.082.0CBL2066 1673 14" Dia. 2065 145581.082.0Ratings based on 8.3% CO2 and -0.04" water draft at the vent.

Two-Stage, Atmospheric, Inter. Ign., Natural GasCBN315 258 315 22482.083.0CBN360 295 360 25782.083.0CBN399 328 399 28582.083.0CBN500 410 500 35782.083.0

Two-Stage, Atmospheric, Inter. Ign., Propane GasCBL315 258 315 22482.083.0CBL360 295 360 25782.083.0CBL399 328 399 28582.083.0CBL500 410 500 35782.083.0

#Copper-Fin II Power Burner, Modulating, Outdoor, Forced Draft, Inter. Ign., Natural Gas

CHN401 335 6" Dia. 399 29184.083.5CHN501 420 6" Dia. 500 36584.083.5CHN651 546 8" Dia. 650 47584.083.5CHN751 630 8" Dia. 750 54884.083.5CHN0991 832 10" Dia. 990 72384.082.0CHN1261 1058 12" Dia. 1260 92084.082.0CHN1441 1210 12" Dia. 1440 105284.082.0CHN1801 1512 14" Dia. 1800 131584.082.0CHN2071 1739 14" Dia. 2070 151284.082.0Ratings based on 8.3% CO2 and -0.04" water draft at the vent.

Power Burner, Modulating, Outdoor, Forced Draft, Inter. Ign., Propane GasCHL401 335 6" Dia. 399 29184.083.5CHL501 420 6" Dia. 500 36584.083.5CHL651 546 8" Dia. 650 47584.083.5CHL751 630 8" Dia. 750 54884.083.5CHL0991 832 10" Dia. 990 72384.082.0CHL1261 1058 12" Dia. 1260 92084.082.0CHL1441 1210 12" Dia. 1440 105284.082.0CHL1801 1512 14" Dia. 1800 131584.082.0CHL2071 1739 14" Dia. 2070 151284.082.0Ratings based on 8.3% CO2 and -0.04" water draft at the vent.

#Intelli-Fin Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural Gas

IBN1500 1380 6" Dia. 1500 120092.089.9IBN1700 1564 7" Dia. 1700 136092.089.9IBN2000 1840 8" Dia. 2000 160092.089.9Ratings based on 9.2% CO2 and +0.15" water draft at the vent.

Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Propane GasIBL1500 1380 6" Dia. 1500 120092.089.9

APR 2009 - 40# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 11: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

LOCHINVAR CORPORATION

COPPER

#Intelli-Fin Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Propane Gas

IBL1700 1564 7" Dia. 1700 136092.089.9IBL2000 1840 8" Dia. 2000 160092.089.9Ratings based on 9.2% CO2 and +0.15" water draft at the vent.

#Power Fin Power Burner, Forced Draft, Inter. Ign., Natural Gas

PBN0502-F9 425 7" Dia. 500 37085.085.0PBN0752-F9 637 9" Dia. 750 55485.085.0PBN1002-F9 850 10" Dia. 1000 73985.085.0PBN1302-F9 1105 12" Dia. 1300 96185.085.0Ratings based on 9.2% CO2 and +0.15" water draft at the vent.

Power Burner, Modulating, Forced Draft, Inter. Ign., Natural GasPBN0502 425 7" Dia. 500 37085.085.0PBN0752 637 9" Dia. 750 55485.085.0PBN1002 850 10" Dia. 1000 73985.085.0PBN1302 1105 12" Dia. 1300 96185.085.0Ratings based on 9.2% CO2 and +0.15" water draft at the vent.

#Power-Fin Power Burner, Forced Draft, Inter. Ign., Propane Gas

PBL0502-F9 425 7" Dia. 500 37085.085.0PBL0752-F9 637 9" Dia. 750 55485.085.0PBL1002-F9 850 10" Dia. 1000 73985.085.0PBL1302-F9 1105 12" Dia. 1300 96185.085.0Ratings based on 9.2% CO2 and +0.15" water draft at the vent.

Power Burner, Modulating, Forced Draft, Inter. Ign., Natural GasPBN1501-B9 1260 12" Dia. 1500 109684.083.0PBN1701-B9 1428 14" Dia. 1700 124284.083.0PBN2001-B9 1680 14" Dia. 2000 146184.083.0Ratings based on 8.2% CO2 and -0.02" water draft at the vent.PBN1501-M9 1275 6" Dia. 1500 110985.084.0PBN1701-M9 1445 7" Dia. 1700 125785.084.0PBN2001-M9 1700 8" Dia. 2000 147885.084.0Ratings based on 8.5% CO2 and +0.11" water draft at the vent.PBN0501 425 7" Dia. 500 37085.085.0PBN0751 637 9" Dia. 750 55485.085.0PBN1001 850 10" Dia. 1000 73985.085.0PBN1300 1105 12" Dia. 1300 96185.085.0Ratings based on 9.2% CO2 and +0.15" water draft at the vent.

Power Burner, Modulating, Forced Draft, Inter. Ign., Propane GasPBL1501-B9 1260 12" Dia. 1500 109684.083.0PBL1701-B9 1428 14" Dia. 1700 124284.083.0PBL2001-B9 1680 14" Dia. 2000 146184.083.0Ratings based on 8.2% CO2 and -0.02" water draft at the vent.PBL1501-M9 1275 6" Dia. 1500 110985.084.0PBL1701-M9 1445 7" Dia. 1700 125785.084.0PBL2001-M9 1700 8" Dia. 2000 147885.084.0Ratings based on 8.5% CO2 and +0.11" water draft at the vent.PBL0501 425 7" Dia. 500 37085.085.0PBL0502 425 7" Dia. 500 37085.085.0PBL0751 637 9" Dia. 750 55485.085.0PBL0752 637 9" Dia. 750 55485.085.0PBL1001 850 10" Dia. 1000 73985.085.0PBL1002 850 10" Dia. 1000 73985.085.0PBL1300 1105 12" Dia. 1300 96185.085.0PBL1302 1105 12" Dia. 1300 96185.085.0Ratings based on 9.2% CO2 and +0.15" water draft at the vent.

STAINLESS STEEL

Knight XL Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural Gas

KBN399 373 4" Dia. 399 32493.395.0KBN500 467 4" Dia. 500 40693.395.0

Ratings based on 9.2% CO2 and +0.15" water draft at the vent.KBN600 567 4" Dia. 600 49394.695.0KBN700 660 6" Dia. 700 57494.395.0KBN800 752 6" Dia. 800 65494.095.0Ratings based on 9.4% CO2 and +0.15" water draft at the vent.

Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Propane GasKBL399 373 4" Dia. 399 32493.395.0KBL500 467 4" Dia. 500 40693.395.0Ratings based on 9.2% CO2 and +0.15" water draft at the vent.KBL600 567 4" Dia. 600 49394.695.0KBL700 660 6" Dia. 700 57494.395.0KBL800 752 6" Dia. 800 65494.095.0Ratings based on 9.4% CO2 and +0.15" water draft at the vent.

Sync Power Burner, Modulating, Condensing, Induced Draft, Inter. Ign., Natural Gas

SBL1000 941 6" Dia. 1000 81894.194.7SBN1000 941 6" Dia. 1000 81894.194.7SBL1300 1240 6" Dia. 1300 107895.494.8SBN1300 1240 6" Dia. 1300 107895.494.8SBL1500 1443 6" Dia. 1500 125596.294.8SBN1500 1443 6" Dia. 1500 125596.294.8

NEW YORKER BOILER CO., INC.

STEEL

FR Series Power Burner, Natural Draft, Light Oil

FR265W 265 8x12x15 2302.35 82.284.9FR305W 305 8x12x18 2652.60 83.483.3FR350W 350 8x12x20 3043.00 83.185.0FR400W 400 8x12x20 3483.50 81.883.8FR462W 462 8x12x25 4024.00 82.784.2Ratings based on 12.2% CO2 and -0.02" water draft.

P B HEAT, LLC

CAST IRON

#Series 211A Atmospheric, Inter. Ign., Natural Gas

211A-04 504 630 1575 438 37876.980.0211A-05 672 840 2100 584 50477.480.0211A-06 840 1050 2625 730 63077.780.0211A-07 1008 1260 3150 877 75677.880.0211A-08 1176 1470 3675 1023 88277.980.0211A-09 1344 1680 4229 1169 101578.080.0211A-10 1512 1890 4808 1315 115478.180.0211A-11 1680 2100 5392 1461 129478.280.0211A-12 1848 2310 5971 1607 143378.280.0211A-13 2016 2520 6521 1753 156577.780.0211A-14 2184 2730 7067 1899 169677.880.0211A-15 2352 2940 7608 2045 182677.980.0211A-16 2520 3150 8154 2191 195777.980.0211A-17 2688 3360 8696 2337 208778.080.0211A-18 2856 3570 9238 2483 221778.080.0211A-19 3024 3780 9783 2630 234878.180.0211A-20 3192 3990 10325 2776 247878.180.0211A-21 3360 4200 10871 2922 260978.180.0211A-22 3528 4410 11413 3068 273978.280.0211A-23 3696 4620 11958 3214 287077.980.0211A-24 3864 4830 12500 3360 300077.980.0211A-25 4032 5040 13042 3506 313078.080.0211A-26 4200 5250 13588 3652 326178.080.0211A-27 4368 5460 14129 3798 339178.080.0211A-28 4536 5670 14675 3944 352278.180.0211A-29 4704 5880 15217 4090 365278.180.0211A-30 4872 6090 15763 4237 378378.180.0

APR 2009 - 41# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 12: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

P B HEAT, LLC

CAST IRON

#Series 211A Atmospheric, Inter. Ign., Natural Gas

211A-31 5040 6300 16304 4383 391378.180.0211A-32 5208 6510 16846 4529 404378.180.0211A-33 5376 6720 17392 4675 417478.280.0211A-34 5544 6930 17933 4821 430478.280.0211A-35 5712 7140 18479 4967 443578.280.0211A-36 5880 7350 19021 5113 456578.280.0211A-37 6048 7560 19567 5259 469678.180.0211A-38 6216 7770 20108 5405 482678.180.0211A-39 6384 7980 20654 5551 495778.180.0211A-40 6552 8190 21196 5697 508778.180.0211A-41 6720 8400 21738 5843 521778.180.0211A-42 6888 8610 22283 5990 534878.180.0211A-43 7056 8820 22825 6136 547878.180.0211A-44 7224 9030 23371 6282 560978.280.0211A-45 7392 9240 23913 6428 573978.280.0211A-46 7560 9450 24458 6574 587078.280.0

Atmospheric, Inter. Ign., Propane Gas211A-04 492 615 1538 428 36976.980.0211A-05 656 820 2050 570 49277.480.0211A-06 820 1025 2563 713 61577.780.0211A-07 984 1230 3075 856 73877.880.0211A-08 1148 1435 3588 998 86177.980.0211A-09 1312 1640 4121 1141 98978.080.0211A-10 1476 1845 4688 1283 112578.180.0211A-11 1640 2050 5258 1426 126278.280.0211A-12 1804 2255 5821 1569 139778.280.0211A-13 1968 2460 6367 1711 152877.780.0211A-14 2132 2665 6896 1854 165577.880.0211A-15 2296 2870 7429 1997 178377.980.0211A-16 2460 3075 7958 2139 191077.980.0211A-17 2624 3280 8488 2282 203778.080.0211A-18 2788 3485 9021 2424 216578.080.0211A-19 2952 3690 9550 2567 229278.180.0211A-20 3116 3895 10079 2710 241978.180.0211A-21 3280 4100 10613 2852 254778.180.0211A-22 3444 4305 11142 2995 267478.280.0211A-23 3608 4510 11671 3137 280177.980.0211A-24 3772 4715 12204 3280 292977.980.0211A-25 3936 4920 12733 3423 305678.080.0211A-26 4100 5125 13263 3565 318378.080.0211A-27 4264 5330 13796 3708 331178.080.0211A-28 4428 5535 14325 3850 343878.180.0211A-29 4592 5740 14854 3993 356578.180.0211A-30 4756 5945 15388 4136 369378.180.0211A-31 4920 6150 15917 4278 382078.180.0211A-32 5084 6355 16446 4421 394778.180.0211A-33 5248 6560 16979 4563 407578.280.0211A-34 5412 6765 17508 4706 420278.280.0211A-35 5576 6970 18038 4849 432978.280.0211A-36 5740 7175 18571 4991 445778.280.0211A-37 5904 7380 19100 5134 458478.180.0

#Series 62 Atmospheric, Inter. Ign., Natural or Propane Gas

62-09-W/S 256 320 800 223 19277.580.062-10R-W/S 279 349 872 243 20977.680.062-10-W/S 288 360 900 250 21677.680.062-11-W/S 320 400 1000 278 24077.680.062-12-W/S 352 440 1100 306 26477.680.062-13-W/S 384 480 1200 334 28877.780.062-14-W/S 416 520 1300 362 31277.780.062-15-W/S 448 560 1400 390 33677.780.0Ratings approved with suffix STDG or SPRK

#Series 64 Atmospheric, Inter. Ign., Natural or Propane Gas

64-07 286 345 24981.083.064-07 279 345 873 21079.081.064-08 331 399 28881.083.064-08 323 399 1010 24279.081.064-09 382 460 33281.083.064-09 373 460 1165 28079.081.064-10 430 518 37481.083.064-10 419 518 1310 31479.081.064-11 477 575 41581.083.064-11 466 575 1456 34979.081.064-12 525 633 45781.083.064-12 512 633 1601 38479.081.0

#Series GM Atmospheric, Inter. Ign., Natural Gas

GM-07-SV 280 342 24379.082.0GM-08-SV 327 399 28479.082.0

Series LC/LCE Forced Draft, Light Oil

LC-4 547 9" Dia. 1708 476 4104.8 82.283.7LC-5R 649 9" Dia. 2029 564 4875.6 82.883.7LC-5 707 9" Dia. 2208 615 5306.1 82.883.7LC-6 868 10" Dia. 2713 755 6517.5 83.183.7LC-7 1029 10" Dia. 3217 895 7728.8 83.383.6LC-8 1189 10" Dia. 3717 1034 89210.2 83.583.6LC-9 1350 12" Dia. 4250 1174 102011.6 83.683.6LC-10 1511 12" Dia. 4804 1314 115312.8 83.783.6LC-11 1672 12" Dia. 5367 1454 128814.2 83.883.6LC-12 1832 12" Dia. 5917 1593 142015.6 83.983.6LCE-13 1966 14" Dia. 6358 1710 152617.0 82.283.5LCE-14 2125 14" Dia. 6875 1848 165018.4 82.583.5LCE-15 2284 14" Dia. 7388 1986 177319.8 82.683.5LCE-16 2444 14" Dia. 7908 2125 189821.0 82.883.5LCE-17 2603 14" Dia. 8421 2263 202122.5 82.983.5LCE-18 2763 16" Dia. 8938 2403 214524.0 83.183.5LCE-19 2922 16" Dia. 9454 2541 226925.0 83.283.5LCE-20 3082 16" Dia. 9971 2680 239326.5 83.383.5LCE-21 3256 16" Dia. 10533 2831 252828.0 83.383.6LCE-22 3430 16" Dia. 11096 2983 266329.5 83.483.6LCE-23 3604 16" Dia. 11658 3134 279831.0 83.583.7LCE-24 3777 16" Dia. 12217 3284 293232.5 83.583.7Ratings based on 13.0% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Inter. Ign., Natural GasLC-4 547 9" Dia. 686 1708 476 41079.881.2LC-5R 649 9" Dia. 808 2029 564 48780.381.2LC-5 707 9" Dia. 881 2208 615 53080.381.2LC-6 868 10" Dia. 1077 2713 755 65180.681.1LC-7 1029 10" Dia. 1273 3217 895 77280.881.1LC-8 1189 10" Dia. 1469 3717 1034 89281.081.1LC-9 1350 12" Dia. 1664 4250 1174 102081.181.1LC-10 1511 12" Dia. 1860 4804 1314 115381.281.1LC-11 1672 12" Dia. 2056 5367 1454 128881.381.1LC-12 1832 12" Dia. 2252 5917 1593 142081.481.1LCE-13 1966 14" Dia. 2464 6358 1710 152679.881.0LCE-14 2125 14" Dia. 2657 6875 1848 165080.081.0LCE-15 2284 14" Dia. 2850 7388 1986 177380.281.0LCE-16 2444 14" Dia. 3043 7908 2125 189880.381.0LCE-17 2603 14" Dia. 3236 8421 2263 202180.481.0LCE-18 2763 16" Dia. 3429 8938 2403 214580.681.0LCE-19 2922 16" Dia. 3622 9454 2541 226980.781.0LCE-20 3082 16" Dia. 3815 9971 2680 239380.881.0LCE-21 3256 16" Dia. 4027 10533 2831 252880.881.1LCE-22 3430 16" Dia. 4239 11096 2983 266380.981.1LCE-23 3604 16" Dia. 4451 11658 3134 279881.081.2LCE-24 3777 16" Dia. 4663 12217 3284 293281.081.2

APR 2009 - 42# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 13: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

P B HEAT, LLC

CAST IRON

Series SC/SCT Forced Draft, Light Oil

SC/SCT-05-W/S 343 7" Dia. 1071 298 2573.00 81.783.3SC/SCT-06-W/S 405 9" Dia. 1267 352 3043.50 82.783.7SC/SCT-07-W/S 462 9" Dia. 1446 402 3474.00 82.583.5SC/SCT-08-W/S 519 9" Dia. 1621 451 3894.50 82.383.4SC/SCT-09-W/S 575 10" Dia. 1796 500 4315.0 82.283.2SC/SCT-10-W/S 632 10" Dia. 1975 550 4745.5 82.183.0Ratings based on 12.5% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Inter. Ign., Natural GasSC/SCT-05-W/S 343 7" Dia. 433 1071 298 25779.380.8SC/SCT-06-W/S 405 9" Dia. 505 1267 352 30480.381.2SC/SCT-07-W/S 462 9" Dia. 577 1446 402 34780.081.0SC/SCT-08-W/S 519 9" Dia. 649 1621 451 38979.980.9SC/SCT-09-W/S 575 10" Dia. 722 1796 500 43179.780.7SC/SCT-10-W/S 632 10" Dia. 794 1975 550 47479.680.5Ratings based on 9.5% CO2 and +0.10" water draft at the vent.

TC Series Forced Draft, Light Oil

TC-S/W-04 900 10" Dia. 2813 783 6758.0 80.483.5TC-S/W-05 1166 10" Dia. 3646 1014 87510.4 80.783.5TC-S/W-06 1433 10" Dia. 4538 1246 108912.6 80.883.5TC-S/W-07 1699 12" Dia. 5458 1477 131015.0 81.083.5TC-S/W-08 1965 12" Dia. 6358 1709 152617.4 81.183.5TC-S/W-09 2232 14" Dia. 7221 1941 173319.6 81.183.5TC-S/W-10 2498 14" Dia. 8079 2172 193922.0 81.283.5TC-S/W-11 2764 14" Dia. 8942 2403 214624.5 81.283.5TC-S/W-12 3031 14" Dia. 9804 2636 235326.5 81.383.5TC-S/W-13 3297 14" Dia. 10667 2867 256029.0 81.383.5TC-S/W-14 3563 16" Dia. 11525 3098 276631.5 81.383.5TC-S/W-15 3830 16" Dia. 12392 3330 297433.5 81.483.5TC-S/W-16 4096 16" Dia. 13250 3562 318036.0 81.483.5TC-S/W-17 4362 18" Dia. 14113 3793 338738.5 81.483.5TC-S/W-18 4629 18" Dia. 14975 4025 359440.5 81.483.5Ratings based on 12.3% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix G, GO or LO.

Power Burner, Forced Draft, Inter. Ign., Natural GasTC-S/W-04 900 10" Dia. 1154 2813 783 67578.081.0TC-S/W-05 1166 10" Dia. 1491 3646 1014 87578.281.0TC-S/W-06 1433 10" Dia. 1827 4538 1246 108978.481.0TC-S/W-07 1699 12" Dia. 2163 5458 1477 131078.581.0TC-S/W-08 1965 12" Dia. 2499 6358 1709 152678.681.0TC-S/W-09 2232 14" Dia. 2836 7221 1941 173378.781.0TC-S/W-10 2498 14" Dia. 3172 8079 2172 193978.881.0TC-S/W-11 2764 14" Dia. 3508 8942 2403 214678.881.0TC-S/W-12 3031 14" Dia. 3844 9804 2636 235378.881.0TC-S/W-13 3297 14" Dia. 4180 10667 2867 256078.981.0TC-S/W-14 3563 16" Dia. 4517 11525 3098 276678.981.0TC-S/W-15 3830 16" Dia. 4853 12392 3330 297478.981.0TC-S/W-16 4096 16" Dia. 5189 13250 3562 318078.981.0TC-S/W-17 4362 18" Dia. 5525 14113 3793 338779.081.0TC-S/W-18 4629 18" Dia. 5862 14975 4025 359479.081.0Ratings based on 9.5% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix G, GO or LO.

Water and Steam Series EC/ECT Natural Draft, Light Oil

EC/ECT-05-250-W/S 286 8x12x20 896 249 2152.50 81.984.1EC/ECT-06-275-W/S 321 8x12x20 1004 279 2412.75 83.384.4EC/ECT-06-300-W/S 347 8x12x20 1083 302 2613.00 82.583.7Ratings based on 12.5% CO2 and -0.02" water draft.

STAINLESS STEEL

PINNACLE SERIES

Power Burner, Direct Vent, Condensing, Induced Draft, Inter. Ign., Natural or Propane Gas

PI-399 379 399 33093.495.1

PATTERSON-KELLEY CO. / HARSCO CORP.

ALUMINUM

#MACH Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural or

Propane GasC-300 276 4" Dia. 300 24092.0C-450 414 5" Dia. 450 36092.0C-750 713 6" Dia. 750 62095.0C-900 846 8" Dia. 900 73694.0C-1050 987 8" Dia. 1050 85894.0C-1500 1440 10" Dia. 1500 125296.0C-2000 1920 10" Dia. 2000 167096.0Ratings based on 9.0% CO2 and +0.22" water draft at the vent.

COPPER

#THERMIFIC Pressure Fired, Inter. Ign., Natural or Propane Gas

N-700 595 10" Dia. 700 51785.0N-1000 850 10" Dia. 1000 73985.0Ratings based on 7.5% CO2 and +0.04" water draft.

#THERMIFIC -2 Two-Stage, Pressure Fired, Inter. Ign., Natural or Propane Gas

N-1500-2 1275 12" Dia. 1500 110985.0N-1700-2 1445 12" Dia. 1700 125785.0N-2000-2 1700 12" Dia. 2000 147885.0Ratings based on 7.5% CO2 and -0.04" water draft.

#THERMIFIC-MFD Power Burner, Modulating, Forced Draft, Inter. Ign., Natural or Propane Gas

N-750 MFD 638 4" Dia. 750 55585.0N-1000 MFD 850 4" Dia. 1000 73985.0N-1500 MFD 1275 6" Dia. 1500 110985.0N-2000 MFD 1700 6" Dia. 2000 147885.0N-2500 MFD 2200 10" Dia. 2500 191388.0N-3000 MFD 2640 10" Dia. 3000 229688.0Ratings based on 8.5% CO2 and +1.00" water draft at the vent.

PENNCO, ECR INTERNATIONAL, INC.

CAST IRON

#Series 41H Atmospheric, Inter. Ign., Natural Gas

41H-0300 240 300 750 209 18080.041H-0400 320 400 1000 278 24080.041H-0500 400 500 1250 348 30080.041H-0600 480 600 1500 417 36080.041H-0700 560 700 1750 487 42080.041H-0800 640 800 2000 557 48080.041H-0900 720 900 2250 626 54080.041H-1000 800 1000 2500 696 60080.041H-1100 880 1100 2750 765 66080.041H-1200 960 1200 3000 835 72080.041H-1300 1040 1300 3250 904 78080.041H-1400 1120 1400 3500 974 84080.041H-1500 1200 1500 3750 1043 90080.041H-1600 1280 1600 4008 1113 96280.041H-1700 1360 1700 4283 1183 102880.041H-1800 1440 1800 4563 1252 109580.041H-1900 1520 1900 4838 1322 116180.041H-2000 1600 2000 5117 1391 122880.041H-2100 1680 2100 5392 1461 129480.041H-2200 1760 2200 5671 1530 136180.0

APR 2009 - 43# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 14: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

PENNCO, ECR INTERNATIONAL, INC.

CAST IRON

#Series 41H Atmospheric, Inter. Ign., Natural Gas

41H-2300 1840 2300 5942 1600 142680.041H-2400 1920 2400 6213 1670 149180.041H-2500 2000 2500 6471 1739 155380.041H-2600 2080 2600 6729 1809 161580.041H-2700 2160 2700 6988 1878 167780.041H-2800 2240 2800 7246 1948 173980.041H-2900 2320 2900 7504 2017 180180.041H-3000 2400 3000 7763 2087 186380.0Also approved with suffix SI or WI.

RAYPAK, INC.

COPPER

#ADB Series Atmospheric, Inter. Ign., Natural or Propane Gas

H500 420 500 36584.084.0H751 630 750 54884.084.0H1001 840 1000 73084.084.0H1501 1260 1499 109684.084.0

Condensing, Induced Draft, Inter. Ign., Natural or Propane GasH500CHX 485 2" Dia. 500 42297.097.0H751CHX 728 2" Dia. 750 63397.097.0H1001CHX 970 2" Dia. 1000 84397.097.0H1501CHX 1455 2" Dia. 1499 126597.097.0

#Delta Limited Atmospheric, Inter. Ign., Natural or Propane Gas

H3-399B* 327 399 28482.082.0H4-399B* 327 399 28482.082.0H3-499B* 410 500 35782.082.0H4-499B* 410 500 35782.082.0H3-649B* 533 650 46382.082.0H4-649B* 533 650 46382.082.0H3-749B* 615 750 53582.082.0H4-749B* 615 750 53582.082.0H3-899B* 738 900 64282.082.0H4-899B* 738 900 64282.082.0H3-989B* 811 990 70582.082.0H4-989B* 811 990 70582.082.0H3-1259B* 1033 1260 89882.082.0H4-1259B* 1033 1260 89882.082.0H3-1529B* 1254 1530 109082.082.0H4-1529B* 1254 1530 109082.082.0H3-1799B* 1476 1800 128382.082.0H4-1799B* 1476 1800 128382.082.0H3-1999B* 1639 1999 142582.082.0H4-1999B* 1639 1999 142582.082.0H3-2069B* 1697 2070 147682.082.0H4-2069B* 1697 2070 147682.082.0H3-2339B* 1918 2340 166882.082.0H4-2339B* 1918 2340 166882.082.0Also approved with prefix H1 - H6.

#HI Delta Series Condensing, Induced Draft, Inter. Ign., Natural or Propane Gas

H3402B-CHX 391 2" Dia. 399 34098.098.0H4402B-CHX 391 2" Dia. 399 34098.098.0H3502B-CHX 490 2" Dia. 500 42698.098.0H4502B-CHX 490 2" Dia. 500 42698.098.0H3652B-CHX 637 2" Dia. 650 55498.098.0H4652B-CHX 637 2" Dia. 650 55498.098.0H3752B-CHX 735 2" Dia. 750 63998.098.0H4752B-CHX 735 2" Dia. 750 63998.098.0

H4902B-CHX 882 2" Dia. 900 76798.098.0H8902B-CHX 882 2" Dia. 900 76798.098.0H3992B-CHX 970 2" Dia. 990 84398.098.0H4992B-CHX 970 2" Dia. 990 84398.098.0H41262B-CHX 1235 2" Dia. 1260 107498.098.0H91262B-CHX 1235 2" Dia. 1260 107498.098.0

Induced Draft, Inter. Ign., Natural or Propane GasH3302*B 252 2" Dia. 300 21984.084.0H3302*BE 261 2" Dia. 300 22787.087.0H4302*B 252 2" Dia. 300 21984.0H4302*BE 261 2" Dia. 300 22787.0H3402*B 335 2" Dia. 399 29184.084.0H3402*BE 347 2" Dia. 399 30287.087.0H4402*B 335 2" Dia. 399 29184.0H4402*BE 347 2" Dia. 399 30287.0H3502*B 420 2" Dia. 500 36584.084.0H3502*BE 435 2" Dia. 500 37887.087.0H4502*B 420 2" Dia. 500 36584.0H4502*BE 435 2" Dia. 500 37887.0H3652*B 546 2" Dia. 650 47584.084.0H3652*BE 566 2" Dia. 650 49287.087.0H4652*B 546 2" Dia. 650 47584.0H4652*BE 566 2" Dia. 650 49287.0H3752*B 630 2" Dia. 750 54884.084.0H3752*BE 653 2" Dia. 750 56887.087.0H4752*B 630 2" Dia. 750 54884.0H4752*BE 653 2" Dia. 750 56887.0H3902*B 756 2" Dia. 900 65784.084.0H3902*BE 783 2" Dia. 900 68187.087.0H4902*B 756 2" Dia. 900 65784.0H4902*BE 783 2" Dia. 900 68187.0H4992*B 831 2" Dia. 990 72384.0H4992*BE 861 2" Dia. 990 74987.0H8992*B 831 2" Dia. 990 72384.084.0H8992*BE 861 2" Dia. 990 74987.087.0H41262*B 1058 2" Dia. 1260 92084.0H41262*BE 1096 2" Dia. 1260 95387.0H91262*B 1058 2" Dia. 1260 92084.084.0H91262*BE 1096 2" Dia. 1260 95387.087.0H41532*B 1285 2" Dia. 1530 111784.0H41532*BE 1331 2" Dia. 1530 115787.0H41532B-CHX 1499 2" Dia. 1530 130398.0H91532*B 1285 2" Dia. 1530 111784.084.0H91532*BE 1331 2" Dia. 1530 115787.087.0H41802*B 1512 2" Dia. 1800 131584.0H41802*BE 1566 2" Dia. 1800 136287.0H41802B-CHX 1764 2" Dia. 1800 153498.0H91802*B 1512 2" Dia. 1800 131584.084.0H91802*BE 1566 2" Dia. 1800 136287.087.0H42002*B 1679 2" Dia. 1999 146084.0H42002*BE 1739 2" Dia. 1999 151287.0H42002B-CHX 1959 2" Dia. 1999 170398.0H92002*B 1679 2" Dia. 1999 146084.084.0H92002*BE 1739 2" Dia. 1999 151287.087.0H42072*B 1738 2" Dia. 2070 151184.0H42072*BE 1801 2" Dia. 2070 156687.0H92072*B 1738 2" Dia. 2070 151184.084.0H92072*BE 1801 2" Dia. 2070 156687.087.0H42342*B 1965 2" Dia. 2340 170984.0H42342*BE 2036 2" Dia. 2340 177087.0H92342*B 1965 2" Dia. 2340 170984.084.0H92342*BE 2036 2" Dia. 2340 177087.087.0Also approved with prefix H1 - H6.

#MVB Outdoor, Induced Draft, Inter. Ign., Natural or Propane Gas

H7-503 435 5" Dia. 500 37887.087.0H7-504 420 5" Dia. 500 36584.084.0H7-753 653 6" Dia. 750 56887.087.0

APR 2009 - 44# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 15: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

RAYPAK, INC.

COPPER

#MVB Outdoor, Induced Draft, Inter. Ign., Natural or Propane Gas

H7-754 630 6" Dia. 750 54884.084.0H7-1003 869 7" Dia. 999 75687.087.0H7-1104 924 7" Dia. 1100 80384.084.0H7-1253 1088 8" Dia. 1250 94687.087.0H7-1503 1305 9" Dia. 1500 113587.087.0H7-1504 1260 9" Dia. 1500 109684.084.0H7-1753 1523 9" Dia. 1750 132487.087.0H7-2003 1739 10" Dia. 1999 151287.087.0H7-2004 1679 10" Dia. 1999 146084.084.0

#Raytherm Indoor Atmospheric, Inter. Ign., Natural Gas

H-0962A 789 962 68682.082.0H-1125A 922 1125 80282.082.0H-1223A 1002 1223 87182.082.0H-1336A 1096 1337 95382.082.0H-1468A 1203 1467 104682.082.0H-1631A 1337 1630 116382.082.0H-1826A 1497 1826 130282.082.0Also approved with prefix H1-H6

Atmospheric, Inter. Ign., Natural or Propane GasH-0962A 727 885 63282.082.0H-1125A 849 1035 73882.082.0H-1223A 923 1125 80382.082.0H-1336A 1012 1233 88082.082.0H-1468A 1107 1350 96382.082.0H-1631A 1230 1500 107082.082.0H-1826A 1378 1680 119882.082.0H-2100B 1640 1999 142682.082.0H-2100A 1722 2100 149782.082.0H-2500A 2050 2499 178382.082.0H-3001A 2460 3000 213982.082.0H-3500A 2870 3500 249682.082.0H-4001A 3280 4000 285282.082.0

#Raytherm Indoor & Outdoor Atmospheric, Inter. Ign., Natural or Propane Gas

H-0330 274 334 23882.082.0H-0331 274 334 23882.082.0H-0400 328 399 28582.082.0H-0401 328 399 28582.082.0H-0514A 420 512 36582.082.0H-0624A 515 627 44882.082.0H-0724A 596 726 51882.082.0H-0824A 677 825 58982.082.0Also approved with prefix H1 - H6.

Outdoor, Atmospheric, Inter. Ign., Propane GasH-0514A- 394 481 34382.082.0H-0624A- 483 589 42082.082.0H-724A- 559 682 48682.082.0H-0824A- 636 775 55382.082.0Also approved with prefix H1-H6

#Raytherm Outdoor Atmospheric, Inter. Ign., Natural or Propane Gas

H-0926A 760 926 66182.082.0H-1083A 889 1083 77382.082.0H-1178A 966 1178 84082.082.0H-1287A 1056 1287 91882.082.0H-1414A 1159 1413 100882.082.0H-1571A 1288 1570 112082.082.0H-1758A 1442 1758 125482.082.0

Outdoor, Atmospheric, Inter. Ign., Propane Gas

H-0926A 726 885 63182.082.0H-1083A 849 1035 73882.082.0H-1178A 923 1126 80382.082.0H-1287A 1011 1233 87982.082.0H-1414A 1107 1350 96382.082.0H-1571A 1230 1500 107082.082.0H-1758A 1378 1680 119882.082.0Also approved with prefix H1-H6

RBI WATER HEATERSDIVISION OF MESTEK, INC.

COPPER

#8800 Series Atmospheric, Standing Pilot, Natural Gas

HB2000 1640 2000 142682.0HB2400 1968 2400 171182.0HB2800 2296 2800 199782.0HB3200 2624 3200 228282.0HB3600 2952 3600 256782.0HB4000 3280 4000 285282.0

#8900 Series Atmospheric, Standing Pilot, Natural Gas

HB420 340 420 29681.0HB530 429 530 37381.0HB630 510 630 44381.0HB735 595 735 51781.0HB840 680 840 59181.0HB950 770 950 67081.0HB1050 851 1050 74081.0HB1160 940 1160 81781.0HB1260 1021 1260 88881.0HB1370 1110 1370 96581.0HB1470 1191 1470 103681.0HB1580 1280 1580 111381.0HB1685 1365 1685 118781.0HB1790 1450 1790 126181.0HB1900 1539 1900 133881.0

#Dominator Series Atmospheric, Standing Pilot, Natural or Propane Gas

DB300 252 300 21980.284.0DB400 335 399 29180.884.0DB600 504 600 43881.784.0DB750 630 750 54882.084.0DB900 756 900 65782.084.0DB1050 882 1050 76782.084.0DB1350 1134 1350 98682.084.0DB1500 1260 1500 109782.084.0DB1950 1638 1950 142482.084.0DB2100 1764 2100 153482.184.0

Futera Fusion Condensing, Forced Draft, Standing Pilot, Natural or Propane Gas

CB-500 487 7" Dia. 500 42397.397.0CB-750 730 7" Dia. 750 63597.396.3CB-1000 974 7" Dia. 1000 84797.495.9CB-1250 1218 8" Dia. 1250 105997.495.7CB-1500 1462 8" Dia. 1500 127197.595.5CB-1750 1706 10" Dia. 1750 148397.595.4CB-2000 1950 10" Dia. 1999 169697.595.3Ratings based on 11.0% CO2 and +0.10" water draft at the vent.

#Futera II Series Power Burner, Forced Draft, Inter. Ign., Natural or Propane Gas

FH500 425 500 37085.0FH750 638 750 55585.0FH1000 850 1000 74085.0

APR 2009 - 45# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 16: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

RBI WATER HEATERSDIVISION OF MESTEK, INC.

COPPER

#Futera II Series Power Burner, Forced Draft, Inter. Ign., Natural or Propane Gas

FH1250 1062 1250 92485.0FH1500 1275 1500 110985.0FH1750 1488 1750 129585.0FH1950 1658 1950 144285.0

XLF Power Burner, Modulating, Forced Draft, Inter. Ign., Natural Gas

MB/MW3000 2622 8" Dia. 3000 228085.687.4MB/MW4000 3480 10" Dia. 4000 302685.887.0Ratings based on 9.0% CO2 and +10.00" water draft at the vent.

SLANT/FIN CORPORATION

ALUMINUM

Jaguar Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural Gas

J-390 352 4" Dia. 390 30690.291.6Ratings based on 9.4% CO2 and +0.10" water draft at the vent.

CAST IRON

Eutectic EC-20 Power Burner, Forced Draft, Light Oil

EC-27 269 7" Dia. 2342.25 85.387.4EC-28 298 7" Dia. 2592.50 85.384.7Ratings based on 13.0% CO2 and +0.02" water draft at the vent.

Eutectic EC-20 Gas Power Burner, Forced Draft, Inter. Ign., Natural Gas

EC-27 269 7" Dia. 325 23482.784.7EC-28 298 7" Dia. 361 25982.784.7Ratings based on 10.0% CO2 and +0.02" water draft at the vent.

#Galaxy Series Damper, Atmospheric, Inter. Ign., Natural Gas

GXH-300HD 243 300 21181.0GXH-300HED 243 300 21181.0GXH-300HEDPZ 243 300 758 18281.0GG-350HEDP 291 350 25383.0

Damper, Atmospheric, Inter. Ign., Natural or Propane GasGG-300EDP 240 300 20980.0GXH-300D 240 300 20980.0GG-325EDP 260 325 22680.0GG-350EDP 280 350 24380.0GG-375HEDP 304 375 26481.0GG-399HEDP 327 399 28482.0

Damper, Atmospheric, Standing Pilot, Natural GasGXH-300HDPZ 243 300 758 18281.0

Damper, Atmospheric, Standing Pilot, Natural or Propane GasGG-300DP 240 300 20980.0

Damper, Cont. Circ., Atmospheric, Inter. Ign., Natural GasGG-350HEDS 291 350 25383.0

Damper, Cont. Circ., Atmospheric, Inter. Ign., Natural or Propane GasGG-300EDS 240 300 20980.0GG-325EDS 260 325 22680.0GG-350EDS 280 350 24380.0GG-375HEDS 304 375 26481.0GG-399HEDS 327 399 28482.0

Damper, Cont. Circ., Atmospheric, Standing Pilot, Natural or Propane GasGG-300DS 240 300 20980.0

#GGHT Caravan Series

Atmospheric, Inter. Ign., Natural GasGGHT-700E 581 700 50583.0GGHT-1050E 872 1050 75883.0GGHT-1400E 1162 1400 101083.0GGHT-1750E 1453 1750 126383.0GGHT-2100E 1743 2100 151683.0GGHT-2540E 2043 2450 176883.0GGHT-2800AE 2324 2800 202183.0GGHT-3150E 2615 3150 227383.0GGHT-3500E 2905 3500 252683.0

Atmospheric, Inter. Ign., Natural or Propane GasGGHT-750E 608 750 52981.0GGHT-800E 654 798 56982.0GGHT-1125E 912 1125 79381.0GGHT-1200E 981 1197 85382.0GGHT-1500E 1216 1500 105781.0GGHT-1600E 1308 1596 113782.0GGHT-1875E 1520 1875 132181.0GGHT-2000E 1635 1995 142282.0GGHT-2250E 1824 2250 158681.0GGHT-2400E 1962 2394 170682.0GGHT-2625E 2128 2625 185081.0GGHT-2800E 2289 2793 199083.0GGHT-3000E 2432 3000 211581.0GGHT-3200E 2616 3192 227582.0GGHT-3375E 2736 3375 237981.0GGHT-3600E 2943 3591 255982.0GGHT-3750E 3040 3750 264381.0GGHT-4000E 3270 3990 284382.0

#GGT Caravan Series Atmospheric, Inter. Ign., Natural or Propane Gas

GGT-400E 322 400 28082.0GGT-500E 402 500 35080.4GGT-600E 600 600 41780.0GGT-900E 720 900 62680.0GGT-1200E 960 1200 83480.0GGT-1500E 1200 1500 104380.0

Atmospheric, Standing Pilot, Natural or Propane GasGGT-400 322 400 28082.0GGT-500 402 500 35080.4GGT-600 480 600 41780.0GGT-900 720 900 62680.0GGT-1200 960 1200 83480.0GGT-1500 1200 1500 104380.0

#GXHT Caravan Series Atmospheric, Standing Pilot, Natural or Propane Gas

GXHT-380Z 304 380 950 22880.0GXHT-500Z 403 504 1258 30280.0GXHT-750Z 605 756 1892 45480.0

#GXHT-HZ Steam Caravan Series Atmospheric, Standing Pilot, Natural Gas

GXHT-600HZ 486 600 1521 36581.0GXHT-900HZ 729 900 2279 54781.0GXHT-1200HZ 972 1200 3038 72981.0GXHT-1500HZ 1215 1500 3796 91181.0

Intrepid Dual Fuel - Gas Power Burner, Natural Draft, Inter. Ign., Natural Gas

TRF-50 250 8x12x15 310 781 217 18880.483.1TRF-50 271 8x12x15 339 23679.982.3TRF-60 296 8x12x15 375 925 257 22279.182.6TRF-70 310 8x12x15 399 969 270 23377.882.3TRF-60 324 8x12x15 411 28279.081.7TRF-70 348 8x12x15 447 1088 303 26177.882.3TRF-70 378 8x12x15 484 32978.181.0Ratings based on 9.5% CO2.

APR 2009 - 46# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 17: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

SLANT/FIN CORPORATION

CAST IRON

Intrepid Dual Fuel - Oil Power Burner, Natural Draft, Light Oil

TRF-50 250 8x12x15 781 217 1882.15 82.985.7TRF-50 271 8x12x15 2362.35 82.484.8TRF-60 296 8x12x15 925 257 2222.60 81.685.2TRF-60 324 8x12x15 2822.85 81.584.2TRF-70 337 8x12x15 1053 293 2533.00 80.284.8TRF-70 348 8x12x15 1088 303 2613.10 80.284.8TRF-70 378 8x12x15 3293.35 80.683.5Ratings based on 12.3% CO2.

Intrepid Series Power Burner, Natural Draft, Light Oil

TR-50 250 8x12x15 783 217 1882.15 82.585.9TR-50 272 8x12x15 2372.35 82.785.2TR-60 298 8x12x15 933 259 2242.60 81.985.8TR-60 326 8x12x15 2832.85 81.884.7TR-70 399 8x12x15 2943.00 80.783.5TR-70 337 8x12x15 1054 2533.00 80.284.8TR-70 354 8x12x15 1108 308 2663.10 81.585.5TR-70 381 8x12x15 3313.35 81.284.2Ratings based on 13.0% CO2 and -0.02" water draft.

LDWO Caravan Series Power Burner, Natural Draft, Light Oil

LDWO-600-2-5 500 12x12x20 4354.30 82.585.9LDWO-750-2-6 596 12x12x20 5185.2 81.985.8LDWO-850-2-7 684 12x16x20 5956.0 81.585.5LDWO-900-3-5 750 12x16x20 6526.4 82.585.9LDWO-1100-3-6 894 16x16x20 7777.8 81.985.8LDWO-1300-3-7 1026 16x16x20 8929.0 81.585.5LDWO-1700-4-7 1368 16x20x25 119012.0 81.585.5LDWO-2100-5-7 1710 16x20x25 148715.0 81.585.5LDWO-2500-6-7 2052 20x20x25 178418.0 81.585.5LDWO-2900-7-7 2394 20x20x25 208221.0 81.585.5LDWO-3400-8-7 2736 20x24x25 237924.0 81.585.5Ratings based on 13.0% CO2 and -0.02" water draft.

LDZO Caravan Series Power Burner, Natural Draft, Light Oil

LDZO-600-2-5 500 12x12x20 1563 3754.30 82.585.9LDZO-750-2-6 596 12x12x20 1863 4475.2 81.985.8LDZO-850-2-7 684 12x16x20 2138 5136.0 81.585.5LDZO-900-3-5 750 12x16x20 2346 5636.4 82.585.9LDZO-1100-3-6 894 16x16x20 2796 6717.8 81.985.8LDZO-1300-3-7 1026 16x16x20 3208 7709.0 81.585.5LDZO-1700-4-7 1368 16x20x25 4313 103512.0 81.585.5LDZO-2100-5-7 1710 16x20x25 5496 131915.0 81.585.5Ratings based on 13.0% CO2 and -0.02" water draft.

Liberty Dual Fuel Series Power Burner, Natural Draft, Inter. Ign., Natural Gas

LDF-50 250 8x12x15 310 783 217 18880.483.1LDF-50 271 8x12x15 339 23679.982.3LDF-60 296 8x12x15 375 925 257 22279.182.6LDF-70 310 8x12x15 399 971 270 23377.882.3LDF-60 324 8x12x15 411 28279.081.7LDF-70 348 8x12x15 447 1088 303 26177.882.3LDF-70 378 8x12x15 484 32978.181.0Ratings based on 9.5% CO2 and -0.02" water draft.

Power Burner, Natural Draft, Light OilLDF-50 250 8x12x15 783 217 1882.15 82.985.7LDF-50 271 8x12x15 2362.35 82.484.8LDF-60 296 8x12x15 925 257 2222.60 81.685.2LDF-60 324 8x12x15 2822.85 81.584.2LDF-70 337 8x12x15 1054 293 2533.00 80.284.8

LDF-70 348 8x12x15 1088 303 2613.10 80.284.8LDF-70 378 8x12x15 3293.35 80.683.5Ratings based on 12.3% CO2 and -0.02" water draft.

Liberty Series Model L Power Burner, Natural Draft, Light Oil

LD-50 250 8x12x15 783 217 1882.15 82.585.9LD-50 272 8x12x15 2372.35 82.785.2LD-60 298 8x12x15 933 259 2242.60 81.985.8LD-60 326 8x12x15 2832.85 81.884.7LD-70 337 8x12x15 1054 2533.00 80.284.8LD-70 399 8x12x15 2943.00 80.783.5LD-70 354 8x12x15 1108 308 2663.10 81.585.5LD-70 381 8x12x15 3313.35 81.284.2Ratings based on 13.0% CO2 and -0.02" water draft.

LWDF Caravan Series (Dual Fuel) Power Burner, Natural Draft, Inter. Ign., Natural Gas

LWDF-600-2-5 500 12x12x20 620 43580.483.3LWDF-750-2-6 592 12x12x20 750 51579.183.2LWDF-850-2-7 620 12x16x20 798 53977.882.9LWDF-900-3-5 750 12x16x20 930 65280.483.3LWDF-1100-3-6 888 16x16x20 1125 77279.183.2LWDF-1300-3-7 931 16x16x20 1197 81077.882.9LWDF-1700-4-7 1241 16x20x25 1596 107977.882.9LWDF-2100-5-7 1551 16x20x25 1995 134977.882.9LWDF-2500-6-7 1861 20x20x25 2394 161877.882.9LWDF-2900-7-7 2172 20x20x25 2793 188977.882.9LWDF-3400-8-7 2482 20x20x25 3192 215877.882.9Ratings based on 9.5% CO2 and -0.02" water draft.

Power Burner, Natural Draft, Light OilLWDF-600-2-5 500 12x12x20 4354.30 82.985.9LWDF-750-2-6 592 12x12x20 5155.2 81.685.8LWDF-850-2-7 674 12x16x20 5866.0 80.285.5LWDF-900-3-5 750 12x16x20 6526.4 82.985.9LWDF-1100-3-6 888 16x16x20 7727.8 81.685.8LWDF-1300-3-7 1011 16x16x20 8799.0 80.284.5LWDF-1700-4-7 1348 16x20x25 117212.0 80.285.5LWDF-2100-5-7 1685 16x20x25 146515.0 80.285.5LWDF-2500-6-7 2022 20x20x25 175818.0 80.285.5LWDF-2900-7-7 2359 20x20x25 205121.0 80.285.5LWDF-3400-8-7 2696 20x20x25 234424.0 80.285.5Ratings based on 12.3% CO2 and -0.02" water draft.

LZDF Caravan Series (Dual Fuel) Power Burner, Natural Draft, Inter. Ign., Natural Gas

LZDF-600-2-5 500 12x12x20 620 1563 37580.483.3LZDF-750-2-6 592 12x12x20 750 1850 44479.183.2LZDF-850-2-7 620 12x16x20 798 1938 46577.882.9LZDF-900-3-5 750 12x16x20 930 2346 56380.483.3LZDF-1100-3-6 888 16x16x20 1125 2775 66679.183.2LZDF-1300-3-7 931 16x16x20 1197 2908 69877.882.9LZD-1700-4-7 1241 16x20x25 1596 3879 93177.882.9LZD-2100-5-7 1551 16x20x25 1995 4946 118777.882.9Ratings based on 9.5% CO2 and -0.02" water draft.

Power Burner, Natural Draft, Light OilLZDF-600-2-5 500 12x12x20 1563 3754.30 82.985.9LZDF-750-2-6 592 12x12x20 1850 4445.2 81.685.8LZDF-850-2-7 674 12x16x20 2108 5066.0 80.285.5LZDF-900-3-5 750 12x16x20 2346 5636.4 82.985.9LZDF-1100-3-6 888 16x16x20 2775 6667.8 81.685.8LZDF-1300-3-7 1011 16x16x20 3158 7589.0 80.285.5LZDF-1700-4-7 1348 16x20x25 4242 101812.0 80.285.5LZDF-2100-5-7 1685 16x20x25 5408 129815.0 80.285.5Ratings based on 12.3% CO2 and -0.02" water draft.

SMITH CAST IRON BOILERS

CAST IRON

APR 2009 - 47# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 18: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

SMITH CAST IRON BOILERS

CAST IRON

19 Series Power Burner, Forced Draft, Inter. Ign., Natural Gas

19-S/W-03 297 6" Dia. 375 929 258 22379.281.619-S/W-04 413 7" Dia. 520 1292 359 31079.482.719-S/W-05 529 8" Dia. 660 1654 460 39780.082.619-S/W-06 644 8" Dia. 801 2013 560 48380.482.619-S/W-07 760 9" Dia. 942 2375 661 57080.782.619-S/W-08 878 10" Dia. 1082 2738 762 65780.982.619-S/W-09 992 10" Dia. 1223 3100 863 74481.182.619-S/W-10 1107 10" Dia. 1364 3456 963 83081.282.619-S/W-11 1223 10" Dia. 1505 3821 1063 91781.382.619-S/W-12 1339 12" Dia. 1645 4213 1164 101181.482.6Ratings based on 9.7% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Light Oil19-S/W-03 297 6" Dia. 929 258 2232.60 81.684.219-S/W-04 413 7" Dia. 1292 359 3103.60 81.985.219-S/W-05 529 8" Dia. 1654 460 3974.6 82.585.219-S/W-06 644 8" Dia. 2013 560 4835.5 82.985.219-S/W-07 760 9" Dia. 2375 661 5706.5 83.285.219-S/W-08 878 10" Dia. 2738 762 6577.5 83.485.119-S/W-09 992 10" Dia. 3100 863 7448.5 83.685.119-S/W-10 1107 10" Dia. 3456 963 8309.5 83.785.119-S/W-11 1223 10" Dia. 3821 1063 91710.4 83.885.119-S/W-12 1339 12" Dia. 4213 1164 101111.4 83.985.1Ratings based on 12.5% CO2 and +0.10" water draft at the vent.

19A Series Power Burner, Forced Draft, Inter. Ign., Natural Gas

19A-S/W-03 297 7" Dia. 375 929 258 22379.281.619A-S/W-04 413 7" Dia. 520 1292 359 31079.582.719A-S/W-05 575 8" Dia. 725 1796 500 43179.382.119A-S/W-06 738 8" Dia. 931 2308 642 55479.381.719A-S/W-07 901 9" Dia. 1137 2817 783 67679.281.419A-S/W-08 1063 10" Dia. 1342 3321 924 79779.281.319A-S/W-09 1226 10" Dia. 1548 3883 1066 92079.281.219A-S/W-10 1388 10" Dia. 1754 4384 1207 105279.281.119A-S/W-11 1551 12" Dia. 1959 4946 1349 118779.281.119A-S/W-12 1713 12" Dia. 2165 5508 1490 132279.181.0Ratings based on 9.7% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Light Oil19A-S/W-03 297 7" Dia. 929 258 2232.60 81.684.219A-S/W-04 413 7" Dia. 1292 359 3103.60 81.985.219A-S/W-05 575 8" Dia. 1796 500 4315.0 81.884.619A-S/W-06 738 8" Dia. 2308 642 5546.5 81.784.219A-S/W-07 901 9" Dia. 2817 783 6767.9 81.784.019A-S/W-08 1063 10" Dia. 3321 924 7979.3 81.783.819A-S/W-09 1226 10" Dia. 3883 1066 92010.8 81.683.719A-S/W-10 1388 10" Dia. 4383 1207 105212.2 81.683.619A/S/W-11 1551 12" Dia. 4946 1349 118713.6 81.683.619A-S/W-12 1713 12" Dia. 5508 1490 132215.0 81.683.5Ratings based on 12.5% CO2 and +0.10" water draft at the vent.

28A Series Power Burner, Forced Draft, Inter. Ign., Natural Gas

28A-S/W-04 900 10" Dia. 1154 2813 783 67578.081.028A-S/W-05 1166 10" Dia. 1491 3646 1014 87578.281.028A-S/W-06 1433 10" Dia. 1827 4538 1246 108978.481.028A-S/W-07 1699 12" Dia. 2163 5458 1477 131078.581.028A-S/W-08 1965 12" Dia. 2499 6358 1709 152678.681.028A-S/W-09 2232 14" Dia. 2836 7221 1941 173378.781.028A-S/W-10 2498 14" Dia. 3172 8079 2172 193978.881.028A-S/W-11 2764 14" Dia. 3508 8942 2403 214678.881.028A-S/W-12 3031 14" Dia. 3844 9804 2636 235378.881.028A-S/W-13 3297 14" Dia. 4180 10667 2867 256078.981.028A-S/W-14 3563 16" Dia. 4517 11525 3098 276678.981.0

28A-S/W-15 3830 16" Dia. 4853 12392 3330 297478.981.028A-S/W-16 4096 16" Dia. 5189 13250 3562 318078.981.028A-S/W-17 4362 18" Dia. 5525 14113 3793 338779.081.028A-S/W-18 4629 18" Dia. 5862 14975 4025 359479.081.0Ratings based on 9.5% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix G, GO or LO.

Power Burner, Forced Draft, Light Oil28A-S/W-04 900 10" Dia. 2813 783 6758.0 80.483.528A-S/W-05 1166 10" Dia. 3646 1014 87510.4 80.783.528A-S/W-06 1433 10" Dia. 4538 1246 108912.6 80.883.528A-S/W-07 1699 12" Dia. 5458 1477 131015.0 81.083.528A-S/W-08 1965 12" Dia. 6358 1709 152617.4 81.183.528A-S/W-09 2232 14" Dia. 7221 1941 173319.6 81.183.528A-S/W-10 2498 14" Dia. 8079 2172 193922.0 81.283.528A-S/W-11 2764 14" Dia. 8942 2403 214624.5 81.283.528A-S/W-12 3031 14" Dia. 9804 2636 235326.5 81.383.528A-S/W-13 3297 14" Dia. 10667 2867 256029.0 81.383.528A-S/W-14 3563 16" Dia. 11525 3098 276631.5 81.383.528A-S/W-15 3830 16" Dia. 12392 3330 297433.5 81.483.528A-S/W-16 4096 16" Dia. 13250 3562 318036.0 81.483.528A-S/W-17 4362 18" Dia. 14113 3793 338738.5 81.483.528A-S/W-18 4629 18" Dia. 14975 4025 359440.5 81.483.5Ratings based on 12.3% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix G, GO or LO.

28HE Series Power Burner, Forced Draft, Inter. Ign., Natural Gas

28HE-S/W-04 931 10" Dia. 1143 2908 810 69881.483.628HE-S/W-05 1194 10" Dia. 1458 3733 1038 89681.983.628HE-S/W-06 1458 10" Dia. 1773 4625 1268 111082.283.528HE-S/W-07 1722 12" Dia. 2088 5542 1497 133082.583.528HE-S/W-08 1985 12" Dia. 2403 6421 1726 154182.683.528HE-S/W-09 2249 14" Dia. 2718 7275 1956 174682.783.528HE-S/W-10 2513 14" Dia. 3033 8129 2185 195182.883.528HE-S/W-11 2776 14" Dia. 3348 8979 2414 215582.983.528HE-S/W-12 3040 14" Dia. 3663 9833 2643 236083.083.528HE-S/W-13 3304 14" Dia. 3978 10688 2873 256583.083.528HE-S/W-14 3567 16" Dia. 4293 11538 3102 276983.183.528HE-S/W-15 3831 16" Dia. 4608 12392 3331 297483.183.428HE-S/W-16 4095 16" Dia. 4923 13246 3561 317983.283.428HE-S/W-17 4358 18" Dia. 5238 14100 3790 338483.283.428HE-S/W-18 4622 18" Dia. 5553 14954 4019 358983.283.4Ratings based on 10.4% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix G, GO or LO.

Power Burner, Forced Draft, Light Oil28HE-S/W-04 931 10" Dia. 2908 810 6987.9 83.986.228HE-S/W-05 1194 10" Dia. 3733 1038 89610.2 84.486.228HE-S/W-06 1458 10" Dia. 4625 1268 111012.2 84.886.128HE-S/W-07 1722 12" Dia. 5542 1497 133014.4 85.086.128HE-S/W-08 1985 12" Dia. 6421 1726 154116.6 85.286.128HE-S/W-09 2249 14" Dia. 7275 1956 174618.8 85.386.128HE-S/W-10 2513 14" Dia. 8129 2185 195121.0 85.486.128HE-S/W-11 2776 14" Dia. 8979 2414 215523.0 85.586.028HE-S/W-12 3040 14" Dia. 9833 2643 236025.5 85.686.028HE-S/W-13 3304 14" Dia. 10688 2873 256527.5 85.686.028HE-S/W-14 3567 16" Dia. 11538 3102 276929.5 85.786.028HE-S/W-15 3831 16" Dia. 12392 3331 297432.0 85.786.028HE-S/W-16 4095 16" Dia. 13246 3561 317934.0 85.786.028HE-S/W-17 4358 18" Dia. 14100 3790 338436.5 85.886.028HE-S/W-18 4622 18" Dia. 14954 4019 358938.5 85.886.0Ratings based on 13.4% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix G, GO or LO.

3500A Mills Series Power Burner, Natural Draft, Inter. Ign., Natural Gas

3500A-*-06 1165 16x16x19 1499 3642 1013 87477.780.73500A-*-07 1478 16x20x23 1889 4696 1285 112778.280.73500A-*-08 1790 20x20x26 2278 5771 1557 138578.680.83500A-*-09 2103 20x20x30 2668 6804 1829 163378.880.8

APR 2009 - 48# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 19: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

SMITH CAST IRON BOILERS

CAST IRON

3500A Mills Series Power Burner, Natural Draft, Inter. Ign., Natural Gas

3500A-*-10 2415 20x20x33 3057 7813 2100 187579.080.83500A-*-11 2727 20x24x37 3447 8821 2371 211779.180.83500A-*-12 3040 20x24x40 3836 9833 2643 236079.280.83500A-*-13 3352 24x24x44 4226 10842 2915 260279.380.83500A-*-14 3665 24x24x47 4615 11854 3187 284579.480.8Ratings based on 10.0% CO2 and -0.02" water draft.Ratings are also approved for boilers with prefix G or GO. * Insert S for Steam, W for Water Boilers.

Power Burner, Natural Draft, Light Oil3500A-*-06 1165 16x16x19 3642 1013 87410.4 80.183.23500A-*-07 1478 16x20x23 4696 1285 112713.0 80.683.23500A-*-08 1790 20x20x26 5771 1557 138515.8 81.083.33500A-*-09 2103 20x20x30 6804 1829 163318.4 81.283.33500A-*-10 2415 20x20x33 7813 2100 187521.0 81.483.33500A-*-11 2727 20x24x37 8821 2371 211724.0 81.683.33500A-*-12 3040 20x24x40 9833 2643 236026.5 81.783.33500A-*-13 3352 24x24x44 10842 2915 260229.5 81.883.33500A-*-14 3665 24x24x47 11854 3187 284532.0 81.983.3Ratings based on 13.0% CO2 and -0.02" water draft.Ratings are also approved for boilers with prefix G or GO. * Insert S for Steam, W for Water Boilers.

350A Mills Series Power Burner, Natural Draft, Inter. Ign., Natural Gas

350A-*-06 1001 16x16x17 1290 3129 870 75177.680.9350A-*-07 1235 16x16x20 1585 3858 1074 92678.081.0350A-*-08 1470 16x20x23 1879 4667 1278 112078.281.0350A-*-09 1705 16x20x26 2174 5483 1483 131678.481.0350A-*-10 1939 20x20x29 2469 6271 1686 150578.681.0350A-*-11 2174 20x20x32 2763 7033 1890 168878.781.0350A-*-12 2474 20x20x35 3057 7792 2095 187078.881.0350A-*-13 2643 20x24x38 3352 8550 2298 205278.981.0350A-*-14 2878 20x24x41 3646 9308 2503 223478.981.0* Insert S for Steam, W for Water Boilers.

Power Burner, Natural Draft, Light Oil350A-*-06 1001 16x16x17 3129 870 7518.9 80.083.4350A-*-07 1235 16x16x20 3858 1074 92611.0 80.483.5350A-*-08 1470 16x20x23 4667 1278 112013.0 80.683.5350A-*-09 1705 16x20x26 5483 1483 131615.0 80.883.5350A-*-10 1939 20x20x29 6271 1686 150517.2 81.083.5350A-*-11 2174 20x20x32 7033 1890 168819.2 81.183.5350A-*-12 2474 20x20x35 7792 2095 187021.0 81.283.5350A-*-13 2643 20x24x38 8550 2298 205223.0 81.383.5350A-*-14 2878 20x24x41 9308 2503 223425.5 81.483.5Ratings based on 13.0% CO2 and -0.02" water draft.* Insert S for Steam, W for Water Boilers.

4500A Mills Series Power Burner, Natural Draft, Heavy Oil

4500A-*-10 3045 20x24x30 9850 2648 236425.0 81.284.44500A-*-11 3435 24x24x37 11113 2987 266728.0 81.584.34500A-*-12 3825 24x24x44 12375 3326 297031.0 81.884.34500A-*-13 4214 24x28x51 13633 3664 327234.5 81.984.34500A-*-14 4604 24x28x58 14896 4003 357537.5 82.184.24500A-*-15 4994 24x28x65 16154 4343 387740.5 82.384.24500A-*-16 5384 28x28x72 17417 4682 418043.5 82.484.24500A-*-17 5774 28x28x79 18679 5021 448346.5 82.584.24500A-*-18 6163 28x28x86 19938 5359 478550.0 82.684.24500A-*-19 6553 30x30x93 21200 5698 508853.0 82.784.24500A-*-20 6943 30x30x100 22463 6037 539156.0 82.784.14500A-*-21 7333 30x36x107 23721 6377 569359.0 82.884.14500A-*-22 7723 30x36x114 24983 6716 599662.0 82.884.1Ratings based on 12.3% CO2 and -0.01" water draft.

* Insert S for Steam, W for Water Boilers.

Power Burner, Natural Draft, Inter. Ign., Natural Gas4500A-*-10 3080 20x24x30 3920 9963 2678 239178.682.14500A-*-11 3467 24x24x37 4404 11217 3015 269278.781.84500A-*-12 3853 24x24x44 4888 12463 3350 299178.881.64500A-*-13 4240 24x28x51 5372 13717 3687 329278.981.44500A-*-14 4627 24x28x58 5856 14967 4023 359279.081.34500A-*-15 5014 24x28x65 6341 16221 4360 389379.181.14500A-*-16 5400 28x28x72 6825 17471 4696 419379.181.04500A-*-17 5787 28x28x79 7309 18721 5032 449379.280.94500A-*-18 6174 28x28x86 7793 19971 5369 479379.280.94500A-*-19 6560 30x30x93 8277 21221 5704 509379.380.84500A-*-20 6947 30x30x100 8761 22475 6041 539479.380.74500A-*-21 7334 30x36x107 9246 23725 6377 569479.380.74500A-*-22 7720 30x36x114 9730 24975 6713 599479.380.6Ratings based on 9.7% CO2 and -0.02" water draft.Ratings are also approved for boilers with prefix G, LO, and GLO. * Insert S for Steam, W for Water Boilers.

Power Burner, Natural Draft, Light Oil4500A-*-10 3080 20x24x30 9963 2678 239127.0 81.084.64500A-*-11 3467 24x24x37 11217 3015 269230.5 81.284.34500A-*-12 3853 24x24x44 12463 3350 299134.0 81.384.14500A-*-13 4240 24x28x51 13717 3687 329237.0 81.483.94500A-*-14 4627 24x28x58 14967 4023 359240.5 81.483.84500A-*-15 5014 24x28x65 16221 4360 389344.0 81.583.74500A-*-16 5400 28x28x72 17471 4696 419347.5 81.683.54500A-*-17 5787 28x28x79 18721 5032 449351.0 81.683.54500A-*-18 6174 28x28x86 19971 5369 479354.0 81.783.44500A-*-19 6560 30x30x93 21221 5704 509357.0 81.783.34500A-*-20 6947 30x30x100 22475 6041 539461.0 81.783.24500A-*-21 7334 30x36x107 23725 6377 569464.0 81.883.24500A-*-22 7720 30x36x114 24975 6713 599467.0 81.883.2Ratings based on 12.5% CO2 and -0.02" water draft.Ratings are also approved for boilers with prefix G, LO, and GLO. * Insert S for Steam, W for Water Boilers.

6500A Mills Series Power Burner, Natural Draft, Inter. Ign., Natural Gas

6500A-*-15 7194 30x30x55 8936 23271 6256 558580.581.96500A-*-16 7872 30x36x61 9805 25467 6845 611280.381.76500A-*-17 8550 30x36x66 10674 27658 7435 663880.181.66500A-*-18 9228 30x36x72 11543 29854 8024 716579.981.46500A-*-19 9906 36x36x77 12412 32046 8614 769179.881.36500A-*-20 10584 36x36x83 13281 34238 9203 821779.781.36500A-*-21 11262 36x36x88 14150 36433 9793 874479.681.26500A-*-22 11940 36x36x94 15019 38625 10383 927079.581.16500A-*-23 12618 36x42x99 15888 40821 10972 979779.481.16500A-*-24 13297 36x42x105 16758 43017 11563 1032479.381.06500A-*-25 13975 36x42x110 17627 45208 12152 1085079.381.0Ratings based on 12.4% CO2 and -0.02" water draft.* Insert S for Steam, W for Water Boilers.

6500A Series Power Burner, Natural Draft, Heavy Oil

6500A-*-15 7194 30x30x55 23271 6256 558558.0 83.084.46500A-*-16 7872 30x36x61 25467 6845 611263.0 82.884.26500A-*-17 8550 30x36x66 27658 7435 663869.0 82.684.16500A-*-18 9228 30x36x72 29854 8024 716575.0 82.484.06500A-*-19 9906 36x36x77 32046 8614 769180.0 82.383.96500A-*-20 10584 36x36x83 34238 9203 821786.0 82.283.86500A-*-21 11262 36x36x88 36433 9793 874492.0 82.183.76500A-*-22 11940 36x36x94 38625 10383 927097.0 82.083.66500A-*-23 12618 36x42x99 40821 10972 9797103.0 81.983.66500A-*-24 13297 36x42x105 43017 11563 10324108.0 81.883.56500A-*-25 13975 36x42x110 45208 12152 10850114.0 81.783.5Ratings based on 12.4% CO2 and -0.02" water draft.* Insert S for Steam, W for Water Boilers.

Power Burner, Natural Draft, Light Oil6500-*-15 7194 30x30x55 23271 6256 558562.0 83.084.4

APR 2009 - 49# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 20: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

SMITH CAST IRON BOILERS

CAST IRON

6500A Series Power Burner, Natural Draft, Light Oil

6500-*-16 7872 30x36x61 25467 6845 611268.0 83.884.26500-*-17 8550 30x36x66 27658 7435 663874.0 83.684.16500-*-18 9228 30x36x72 29854 8024 716580.0 83.484.06500-*-19 9906 36x36x77 32046 8614 769186.0 82.383.96500-*-20 10585 36x36x83 34242 9204 821892.0 82.283.86500-*-21 11263 36x36x88 36438 9794 874598.0 82.183.76500-*-22 11941 36x36x94 38629 10383 9271104.0 82.083.66500-*-23 12619 36x42x99 40821 10973 9797110.0 81.983.66500-*-24 13297 36x42x105 43017 11563 10324116.0 81.883.56500-*-25 13975 36x42x110 45208 12152 10850122.0 81.783.5Ratings based on 12.4% CO2 and -0.02" water draft.* Insert S for Steam, W for Water Boilers.

650A Mills Series Power Burner, Natural Draft, Heavy Oil

650A-*-15 6247 28x28x47 20208 5432 485050.0 83.384.7650A-*-16 6672 28x28x50 21583 5802 518053.0 83.384.7650A-*-17 7098 30x30x52 22963 6172 551157.0 83.384.8650A-*-18 7523 30x30x54 24338 6542 584160.0 83.384.8650A-*-19 7949 30x36x56 25717 6912 617264.0 83.384.9650A-*-20 8374 30x36x58 27092 7282 650267.0 83.384.9650A-*-21 8799 30x36x61 28467 7651 683270.0 83.385.0650A-*-22 9225 30x36x64 29842 8022 716274.0 83.385.0650A-*-23 9650 36x36x67 31217 8391 749277.0 83.385.0650A-*-24 10076 36x36x69 32596 8762 782381.0 83.385.0650A-*-25 10501 36x36x71 33971 9131 815384.0 83.385.1Ratings based on 12.4% CO2 and -0.02" water draft.* Insert S for Steam, W for Water Boilers.

Power Burner, Natural Draft, Inter. Ign., Natural Gas650A-*-15 6247 28x28x47 7732 20208 5432 485080.882.1650A-*-16 6672 28x28x50 8258 21583 5802 518080.882.2650A-*-17 7098 30x30x52 8784 22963 6172 551180.882.3650A-*-18 7523 30x30x54 9309 24338 6542 584180.882.3650A-*-19 7949 30x36x56 9835 25717 6912 617280.882.3650A-*-20 8374 30x36x58 10361 27092 7282 650280.882.4650A-*-21 8799 30x36x61 10887 28467 7651 683280.882.4650A-*-22 9225 30x36x64 11412 29842 8022 716280.882.4650A-*-23 9650 36x36x67 11938 31217 8391 749280.882.5650A-*-24 10076 36x36x69 12464 32596 8762 782380.882.5650A-*-25 10501 36x36x71 12990 33971 9131 815380.882.6* Insert S for Steam, W for Water Boilers.

#G250 Series Power Burner, Atmospheric, Inter. Ign., Natural Gas

GB250-S-7-INT 240 300 750 18075.880.0GB250-S-8-INT 280 350 875 21075.880.0GB250-S-9-INT 320 400 1000 24075.880.0Ratings also approved with the suffix D for Stack Damper

Power Burner, Atmospheric, Inter. Ign., Propane GasPGB250-S-7-INT 240 300 750 18075.880.0PGB250-S-8-INT 280 350 875 21075.880.0PGB250-S-9-INT 288 360 900 21675.880.0Ratings also approved with the suffix D for Stack Damper

Power Burner, Atmospheric, Standing Pilot, Natural GasGB250-S-7-CON 240 300 750 18075.880.0GB250-S-8-CON 280 350 875 21075.880.0GB250-S-9-CON 320 400 1000 24075.880.0Ratings also approved with the suffix D for Stack Damper

Power Burner, Atmospheric, Standing Pilot, Propane GasPGB250-S-7-CON 240 300 750 18075.880.0PGB250-S-8-CON 280 350 875 21075.880.0PGB250-S-9-CON 288 360 900 21675.880.0Ratings also approved with the suffix D for Stack Damper

M450A Mills Series Power Burner, Natural Draft, Heavy Oil

M450A-*-10 2449 20x20x29 7921 2130 190119.6 83.585.9M450A-*-11 2733 20x24x33 8842 2377 212222.0 83.785.9M450A-*-12 3016 20x24x37 9758 2623 234224.0 83.986.0M450A-*-13 3300 24x24x40 10675 2870 256226.0 84.086.0M450A-*-14 3583 24x24x44 11592 3116 278228.5 84.186.0M450A-*-15 3867 24x24x47 12508 3363 300230.5 84.286.0M450A-*-16 4151 24x28x53 13429 3610 322333.0 84.386.0M450A-*-17 4434 24x28x59 14346 3856 344335.0 84.386.0M450A-*-18 4718 24x28x65 15263 4103 366337.5 84.486.1M450A-*-19 5001 28x28x71 16179 4349 388339.5 84.586.1M450A-*-20 5285 28x28x77 17096 4596 410341.5 84.586.1M450A-*-21 5568 28x28x82 18013 4842 432344.0 84.686.1M450A-*-22 5852 28x28x88 18929 5089 454346.0 84.686.1Ratings based on 12.5% CO2 and -0.02" water draft.* Insert S for Steam, W for Water Boilers.

Power Burner, Natural Draft, Inter. Ign., Natural Gas

M450A-*-10 2449 20x20x29 3031 7921 2130 190180.883.7M450A-*-11 2733 20x24x33 3380 8842 2377 212280.983.4M450A-*-12 3016 20x24x37 3729 9758 2623 234280.983.2M450A-*-13 3300 24x24x40 4077 10675 2870 256280.983.0M450A-*-14 3583 24x24x44 4426 11592 3116 278281.082.9M450A-*-15 3867 24x24x47 4775 12508 3363 300281.082.7M450A-*-16 4151 24x28x53 5124 13429 3610 322381.082.6M450A-*-17 4434 24x28x59 5473 14346 3856 344381.082.5M450A-*-18 4718 24x28x65 5821 15263 4103 366381.082.4M450A-*-19 5001 28x28x71 6170 16179 4349 388381.182.4M450A-*-20 5285 28x28x77 6519 17096 4596 410381.182.3M450A-*-21 5568 28x28x82 6868 18013 4842 432381.182.2M450A-*-22 5852 28x28x88 7216 18929 5089 454381.182.2Ratings based on 9.5% CO2 and -0.02" water draft.* Insert S for Steam, W for Water Boilers.

Power Burner, Natural Draft, Light OilM450A-*-10 2449 20x20x29 7921 2130 190121.0 83.386.3M450A-*-11 2733 20x24x33 8842 2377 212223.5 83.486.0M450A-*-12 3016 20x24x37 9758 2623 234226.0 83.485.8M450A-*-13 3300 24x24x40 10675 2870 256228.5 83.485.6M450A-*-14 3583 24x24x44 11592 3116 278230.5 83.585.4M450A-*-15 3867 24x24x47 12508 3363 300233.0 83.585.3M450A-*-16 4151 24x28x53 13429 3610 322335.5 83.585.2M450A-*-17 4434 24x28x59 14346 3856 344338.0 83.585.1M450A-*-18 4718 24x28x65 15263 4103 366340.5 83.585.0M450A-*-19 5001 28x28x71 16179 4349 388343.0 83.684.9M450A-*-20 5285 28x28x77 17096 4596 410345.0 83.684.8M450A-*-21 5568 28x28x82 18013 4842 432347.5 83.684.8M450A-*-22 5852 28x28x88 18929 5089 454350.0 83.684.8Ratings based on 12.5% CO2 and -0.02" water draft.* Insert S for Steam, W for Water Boilers.

A.O. SMITH WATER PRODUCTS CO.

COPPER

#Burkay Atmospheric, Inter. Ign., Natural or Propane Gas

HW-300 247 300 21582.080.0HW-399 323 399 28182.080.0HW-420 344 420 29982.080.0HW-520 429 520 37382.080.0HW-670 544 660 47380.080.0

#Duramax Atmospheric, Inter. Ign., Natural Gas

DB-720 583 720 50781.080.0DB-840 680 840 59181.080.0DB-960 778 960 67781.080.0DB-1080 886 1080 77082.080.0

APR 2009 - 50# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 21: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

A.O. SMITH WATER PRODUCTS CO.

COPPER

#Duramax Atmospheric, Inter. Ign., Natural Gas

DB-1210 992 1210 86382.080.0DB-1350 1107 1350 96382.080.0DB-1480 1184 1480 103080.080.0DB-1610 1288 1610 112080.080.0DB-1810 1448 1810 125980.080.0

#Genesis 400 Modulating, Induced Draft, Inter. Ign., Natural or Propane Gas

GB-300 251 5" Dia. 300 21883.082.0GB-400 335 6" Dia. 400 29183.082.0GB-500 419 6" Dia. 500 36483.082.0GB-650 544 8" Dia. 650 47383.082.0GB-750 628 8" Dia. 750 54683.082.0GB-1000 832 10" Dia. 990 72383.082.0GB-1300 1092 12" Dia. 1300 95083.082.0GB-1500 1260 12" Dia. 1500 109683.082.0GB-1850 1554 14" Dia. 1850 135183.082.0GB-2100 1764 14" Dia. 2100 153483.082.0GB-2500 2092 16" Dia. 2500 181983.082.0

#Genesis 400 Outdoor Modulating, Outdoor, Induced Draft, Inter. Ign., Natural or Propane Gas

GBO-300 251 5" Dia. 300 21883.082.0GBO-400 335 6" Dia. 400 29183.082.0GBO-500 419 6" Dia. 500 36483.082.0GBO-650 544 8" Dia. 650 47383.082.0GBO-750 628 8" Dia. 750 54683.082.0GBO-1000 832 10" Dia. 990 72383.082.0GBO-1300 1092 12" Dia. 1300 95083.082.0GBO-1500 1260 12" Dia. 1500 109683.082.0GBO-1850 1554 14" Dia. 1850 135183.082.0GBO-2100 1764 14" Dia. 2100 153483.082.0GBO-2500 2092 16" Dia. 2490 181983.082.0

#VF Series - VBs Modulating, Induced Draft, Inter. Ign., Natural or Propane Gas

VB 500 413 8" Dia. 500 35984.0VB 750 619 8" Dia. 750 53884.0VB 1,000 830 8" Dia. 1000 72284.0

THERMAL SOLUTIONS PRODUCTS, LLC

STAINLESS STEEL

Evolution Condensing Modulating, Condensing, Forced Draft, Inter. Ign., Natural or Propane Gas

EVCA0750B**-*A* 699 4" Dia. 750 60893.291.3EVCA0750B**-*B* 699 4" Dia. 750 60893.291.3EVCA0750B**-*C* 699 4" Dia. 750 60893.291.3EVCA0750B**-*D* 699 4" Dia. 750 60893.291.3EVCA0750B**-*E* 699 4" Dia. 750 60893.291.3EVCA0750B**-*F* 699 4" Dia. 750 60893.291.3EVC1000B**-*B* 939 6" Dia. 1000 81793.991.8EVCA1000B**-*A* 939 6" Dia. 1000 81793.991.8EVCA1000B**-*C* 939 6" Dia. 1000 81793.991.8EVCA1000B**-*D* 939 6" Dia. 1000 81793.991.8EVCA1000B**-*E* 939 6" Dia. 1000 81793.991.8EVCA1000B**-*F* 939 6" Dia. 1000 81793.991.8EVCA1500B**-*A* 1420 6" Dia. 1500 123594.792.3EVCA1500B**-*B* 1420 6" Dia. 1500 123594.792.3EVCA1500B**-*C* 1420 6" Dia. 1500 123594.792.3EVCA1500B**-*D* 1420 6" Dia. 1500 123594.792.3EVCA1500B**-*E* 1420 6" Dia. 1500 123594.792.3EVCA1500B**-*F* 1420 6" Dia. 1500 123594.792.3

EVCA2000B**-*A* 1900 6" Dia. 2000 165295.092.5EVCA2000B**-*B* 1900 6" Dia. 2000 165295.092.5EVCA2000B**-*C* 1900 6" Dia. 2000 165295.092.5EVCA2000B**-*D* 1900 6" Dia. 2000 165295.092.5EVCA2000B**-*E* 1900 6" Dia. 2000 165295.092.5EVCA2000B**-*F* 1900 6" Dia. 2000 165295.092.5Ratings based on 11.0% CO2 and +0.10" water draft at the vent.

THERMO-DYNAMICS BOILER CO.

STEEL

HT Series Forced Draft, Light Oil

HT-225 264 8" Dia. 2302.25 83.785.6HT-250 291 8" Dia. 2532.50 83.485.2HT-275 319 8" Dia. 2772.75 82.984.9Ratings based on 13.2% CO2 and -0.02" water draft at the vent.

TRIANGLE TUBE

STAINLESS STEEL

Prestige Power Burner, Modulating, Condensing, Pressure Fired, Inter. Ign., Natural or

Propane GasSolo 399 379 4" Dia. 399 33095.194.1Ratings based on 9.0% CO2 and 0" water draft.

UTICA BOILERS, ECR INTERNATIONAL, INC.

CAST IRON

#J-C Series Atmospheric, Inter. Ign., Natural Gas

JC-300 240 300 750 209 18080.0JC-400 320 400 1000 278 24080.0JC-500 400 500 1250 348 30080.0JC-600 480 600 1500 417 36080.0JC-700 560 700 1750 487 42080.0JC-800 640 800 2000 557 48080.0JC-900 720 900 2250 626 54080.0JC-1000 800 1000 2500 696 60080.0JC-1100 880 1100 2750 765 66080.0JC-1200 960 1200 3000 835 72080.0JC-1300 1040 1300 3250 904 78080.0JC-1400 1120 1400 3500 974 84080.0JC-1500 1200 1500 3750 1043 90080.0JC1600 1280 1600 4008 1113 96280.0JC-1700 1360 1700 4283 1183 102880.0JC-1800 1440 1800 4563 1252 109580.0JC-1900 1520 1900 4838 1322 116180.0JC-2000 1600 2000 5117 1391 122880.0JC-2100 1680 2100 5392 1461 129480.0JC-2200 1760 2200 5671 1530 136180.0JC-2300 1840 2300 5942 1600 142680.0JC-2400 1920 2400 6213 1670 149180.0JC-2500 2000 2500 6471 1739 155380.0JC-2600 2080 2600 6729 1809 161580.0JC-2700 2160 2700 6988 1878 167780.0JC-2800 2240 2800 7246 1948 173980.0JC-2900 2320 2900 7504 2017 180180.0JC-3000 2400 3000 7763 2087 186380.0

Starfire Steam Series Natural Draft, Light Oil

SFH6225 251 8x12x15 783 218 1882.25 79.783.3SFH7275 307 8x12x15 958 267 2302.75 79.783.3Ratings based on 13.0% CO2 and -0.02" water draft.

Starfire Water Series

APR 2009 - 51# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 22: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

UTICA BOILERS, ECR INTERNATIONAL, INC.

CAST IRON

Starfire Water Series Natural Draft, Light Oil

SFH6225W 255 8x12x15 2182.25 80.983.3SFH7275W 312 8x12x15 2672.75 80.983.3Ratings based on 13.0% CO2 and -0.01" water draft.

VIESSMANN MANUFACTURING COMPANY, INC.

CAST IRON

#VITOGAS 100, GS10 Series Atmospheric, Inter. Ign., Natural or Propane Gas

GS10-72 257 300 22385.6GS10-84 291 340 25385.6GS10-96 325 380 28385.6

#VITOGAS 50-RS Atmospheric, Inter. Ign., Natural or Propane Gas

RS-08 468 550 40785.0RS-11 680 800 59185.0RS-14 893 1050 77685.0

Vitorond 200 Gas Power Burner, Two-Stage, Pressure Fired, Inter. Ign., Natural or Propane Gas

VD2-125 433 8" Dia. 508 37785.284.7VD2-160 553 8" Dia. 650 48185.184.8VD2-195 672 8" Dia. 792 58484.884.8VD2-230 792 10" Dia. 934 68984.884.8VD2-270 928 10" Dia. 1096 80784.784.8VD2-320 1110 12" Dia. 1300 96585.485.5VD2-380 1319 12" Dia. 1544 114785.485.4VD2-440 1526 12" Dia. 1787 132785.485.4VD2-500 1732 14" Dia. 2031 150685.385.3VD2-560 1941 14" Dia. 2275 168885.385.2VD2-630 2183 14" Dia. 2559 189885.385.1VD2-700 2425 16" Dia. 2843 210985.385.1VD2-780 2699 16" Dia. 3168 234785.285.0VD2-860 2976 16" Dia. 3493 258885.284.9VD2-950 3135 18" Dia. 3680 272685.284.8VD2-1080 3738 18" Dia. 4387 325085.284.6Ratings based on 11.0% CO2 and -0.03" water draft.

Vitorond 200-Oil Power Burner, Two-Stage, Pressure Fired, Light Oil

VD2-125 433 8" Dia. 3773.50 87.987.7VD2-160 553 8" Dia. 4814.50 87.687.3VD2-195 672 8" Dia. 5845.5 87.487.3VD2-230 792 10" Dia. 6896.5 87.387.3VD2-270 928 10" Dia. 8077.6 87.287.3VD2-320 1110 12" Dia. 9659.0 88.088.1VD2-380 1319 12" Dia. 114710.6 88.088.0VD2-440 1526 12" Dia. 132712.4 88.088.0VD2-500 1732 14" Dia. 150614.0 88.087.9VD2-560 1941 14" Dia. 168815.8 88.087.8VD2-630 2183 14" Dia. 189817.8 87.987.8VD2-700 2425 16" Dia. 210919.6 87.987.7VD2-780 2699 16" Dia. 234722.0 87.987.6VD2-860 2976 16" Dia. 258824.2 87.987.5VD2-950 3135 18" Dia. 272627.0 87.887.4VD2-1080 3738 18" Dia. 325030.4 87.887.3Ratings based on 13.1% CO2 and -0.03" water draft.

STAINLESS STEEL

Vitocrossal 300 Power Burner, Modulating, Condensing, Forced Draft, Inter. Ign., Natural or

Propane Gas

CT3-17 626 8" Dia. 638 54498.198.3CT3-22 827 8" Dia. 846 71997.797.8CT3-28 1044 8" Dia. 1071 90897.497.4CT3-37 1350 10" Dia. 1389 117497.297.2CT3-46 1675 10" Dia. 1726 145797.197.1CT3-57 2094 10" Dia. 2160 182196.996.9CT3-72 2616 12" Dia. 2702 227596.896.8CT3-89 3252 12" Dia. 3361 282896.796.7Ratings based on 10.0% CO2 and 0" water draft at the vent.

WEIL-MCLAIN

ALUMINUM

Ultra Series 3 Modulating, Condensing, Induced Draft, Inter. Ign., Natural or Propane Gas

ULTRA 310 288 4" Dia. 310 2502.05 92.993.3ULTRA 399 364 4" Dia. 399 31791.391.7

CAST IRON

80 Series 1 Forced Draft, Light Oil

380 278 8" Dia. 867 242 2082.40 82.785.3480 396 8" Dia. 1238 344 2973.40 83.285.5580 515 8" Dia. 1608 448 3864.45 83.185.1680 634 8" Dia. 1983 551 4765.5 83.184.9780 753 10" Dia. 2354 655 5656.5 83.184.7880 872 10" Dia. 2725 758 6547.5 83.084.6980 991 10" Dia. 3096 862 7438.5 83.084.51090 1110 10" Dia. 3471 965 8339.6 83.084.41180 1229 10" Dia. 3842 1069 92210.6 83.084.41280 1348 12" Dia. 4242 1172 101811.6 83.084.3Ratings based on 13.0% CO2 and +0.10" water draft at the vent.

Power Burner, Forced Draft, Inter. Ign., Natural Gas380 278 8" Dia. 346 867 242 20880.282.7480 396 8" Dia. 491 1238 344 29780.782.9580 515 8" Dia. 639 1608 448 38680.682.6680 634 8" Dia. 787 1983 551 47680.682.3780 753 10" Dia. 935 2354 655 56580.682.2880 872 10" Dia. 1082 2725 758 65480.682.0980 991 10" Dia. 1230 3096 862 74380.582.01090 1110 10" Dia. 1378 3471 965 83380.581.91180 1229 10" Dia. 1526 3842 1069 92280.581.81280 1348 12" Dia. 1674 4242 1172 101880.581.8

88 Series 1 Forced Draft, Light Oil

488R 794 10" Dia. 2483 690 5966.9 82.284.4488 810 10" Dia. 2533 704 6087.0 82.284.4588 1084 10" Dia. 3388 943 8139.4 82.284.1688 1358 10" Dia. 4275 1181 102611.8 82.383.9788 1632 12" Dia. 5225 1419 125414.2 82.383.8888 1904 12" Dia. 6154 1656 147716.6 82.383.7988R 1991 14" Dia. 6442 1731 154617.2 82.383.7988 2176 14" Dia. 7038 1892 168918.8 82.383.71088R 2304 14" Dia. 7454 2003 178920.0 82.383.61088 2452 14" Dia. 7933 2132 190421.5 82.383.61188 2724 14" Dia. 8813 2369 211523.5 82.383.61288 3000 14" Dia. 9704 2609 232926.0 82.383.51388 3270 14" Dia. 10579 2843 253928.5 82.383.51488 3550 16" Dia. 11483 3087 275631.0 82.383.51588 3820 16" Dia. 12358 3322 296633.0 82.383.51688R 3980 16" Dia. 12875 3461 309034.5 82.383.51688 4090 16" Dia. 13229 3557 317535.5 82.383.51788 4370 18" Dia. 14138 3800 339338.0 82.383.41888 4640 18" Dia. 15008 4035 360240.5 82.383.4Ratings based on 12.5% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix BL, BG, BGL, ABL, ABG, ABGL, PG, PL, and PGL and suffix WF and SF.

APR 2009 - 52# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 23: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

WEIL-MCLAIN

CAST IRON

88 Series 1 Power Burner, Forced Draft, Inter. Ign., Natural Gas

488R 794 10" Dia. 996 2483 690 59679.781.9488 810 10" Dia. 1010 2533 704 60879.781.9588 1084 10" Dia. 1357 3388 943 81379.881.6688 1358 10" Dia. 1703 4275 1181 102679.881.4788 1632 12" Dia. 2049 5225 1419 125479.881.3888 1904 12" Dia. 2396 6154 1656 147779.881.2988R 1991 14" Dia. 2482 6442 1731 154679.881.2988 2176 14" Dia. 2713 7038 1892 168979.881.21088R 2304 14" Dia. 2887 7454 2003 178979.881.11088 2452 14" Dia. 3103 7933 2132 190479.881.11188 2724 14" Dia. 3392 8813 2369 211579.881.11288 3000 14" Dia. 3753 9704 2609 232979.881.01388 3270 14" Dia. 4113 10579 2843 253979.981.01488 3550 16" Dia. 4474 11483 3087 275679.981.01588 3820 16" Dia. 4763 12358 3322 296679.981.01688R 3980 16" Dia. 4979 12875 3461 309079.981.01688 4090 16" Dia. 5124 13229 3557 317579.981.01788 4370 18" Dia. 5485 14138 3800 339379.980.91888 4640 18" Dia. 5845 15008 4035 360279.980.9Ratings based on 9.5% CO2 and +0.10" water draft at the vent.

88 Series 2 gas Power Burner, Forced Draft, Inter. Ign., Natural Gas

488R 827 10" Dia. 996 2585 719 62083.184.8488 839 10" Dia. 1010 2623 730 62983.184.8588 1126 10" Dia. 1356 3520 979 84583.184.4688 1413 10" Dia. 1701 4467 1229 107283.184.1788 1700 12" Dia. 2046 5463 1478 131183.183.9888 1987 12" Dia. 2382 6428 1728 154383.183.7988R 2062 14" Dia. 2482 6671 1793 160183.183.7988 2274 14" Dia. 2737 7356 1977 176683.183.71088R 2399 14" Dia. 2887 7761 2086 186383.183.61088 2561 14" Dia. 3082 8285 2227 198883.183.61188 2848 14" Dia. 3428 9213 2477 221183.183.51288 3135 14" Dia. 3773 10142 2726 243483.183.51388 3422 14" Dia. 4119 11070 2976 265783.183.41488 3709 16" Dia. 4464 11999 3225 288083.183.41588 3996 16" Dia. 4809 12927 3475 310283.183.31688R 4137 16" Dia. 4979 13383 3597 321283.183.31688 4283 16" Dia. 5155 13855 3724 332583.183.31788 4570 18" Dia. 5494 14784 3974 354883.183.31888 4857 18" Dia. 5845 15712 4223 377183.183.3Ratings based on 9.5% CO2 and +0.10" water draft at the vent.Also approved with prefix BG, BLG, ABG, ABGL,PG, PGL, and suffis WF and SF

88 Series 2 Oil Power Burner, Forced Draft, Light Oil

488R 827 10" Dia. 2585 719 6206.9 85.687.5488 839 10" Dia. 2623 730 6297.0 85.687.5588 1126 10" Dia. 3520 979 8459.4 85.687.0688 1413 10" Dia. 4467 1229 107211.8 85.686.7788 1700 12" Dia. 5463 1478 131114.2 85.686.5888 1987 12" Dia. 6428 1728 154316.6 85.686.3988R 2062 14" Dia. 6671 1793 160117.2 85.686.2988 2274 14" Dia. 7356 1977 176619.0 85.686.21088R 2399 14" Dia. 7761 2086 186320.0 85.686.21088 2561 14" Dia. 8285 2227 198821.4 85.686.21188 2848 14" Dia. 9213 2477 221123.8 85.786.11288 3135 14" Dia. 10142 2726 243426.2 85.786.01388 3422 14" Dia. 11070 2976 265728.6 85.786.01488 3709 16" Dia. 11999 3225 288031.0 85.786.01588 3996 16" Dia. 12927 3475 310233.4 85.785.91688R 4137 16" Dia. 13383 3597 321234.6 85.785.91688 4283 16" Dia. 13855 3724 332535.8 85.785.9

1788 4570 18" Dia. 14784 3974 354838.2 85.785.91888 4857 18" Dia. 15712 4223 377140.6 85.785.9Ratings based on 12.5% CO2 and +0.10" water draft at the vent.Also approved with prefix BL, BGL, ABL, ABGL, PL, and PGL and suffix WF and SF

94 Series 3 Forced Draft, Heavy Oil

894 2028 14" Dia. 6563 1763 157516.6 81.083.6994 2320 14" Dia. 7504 2017 180119.0 81.183.61094 2612 16" Dia. 8450 2271 202821.5 81.183.61194 2904 16" Dia. 9396 2525 225524.0 81.283.61294 3190 16" Dia. 10321 2774 247726.0 81.383.61394 3480 18" Dia. 11258 3026 270228.5 81.383.61494 3770 18" Dia. 12196 3278 292731.0 81.483.61594 4070 18" Dia. 13167 3539 316033.0 81.483.61694 4360 18" Dia. 14104 3791 338535.5 81.583.61794 4650 20" Dia. 15042 4043 361038.0 81.683.61894 4940 20" Dia. 15979 4296 383540.5 81.683.61994 5230 20" Dia. 16921 4548 406142.5 81.783.62094 5520 20" Dia. 17858 4800 428645.0 81.883.6Ratings based on 12.3% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix BL, BG, BGL, ABL, ABG, ABGL, PG, PL, and PGL and suffix WF and SF.

Forced Draft, Light Oil894 2028 14" Dia. 6563 1763 157517.6 82.783.7994 2320 14" Dia. 7504 2017 180120.0 82.883.81094 2612 16" Dia. 8450 2271 202822.5 82.883.81194 2904 16" Dia. 9396 2525 225525.0 82.883.91294 3190 16" Dia. 10321 2774 247727.5 82.883.91394 3480 18" Dia. 11258 3026 270230.0 82.883.91494 3770 18" Dia. 12196 3278 292732.5 82.983.91594 4070 18" Dia. 13167 3539 316035.0 82.984.01694 4360 18" Dia. 14104 3791 338537.5 82.984.01794 4650 20" Dia. 15042 4043 361040.0 82.984.01894 4940 20" Dia. 15979 4296 383542.5 82.984.01994 5230 20" Dia. 16921 4548 406145.0 83.084.02094 5520 20" Dia. 17858 4800 428647.5 83.084.02194 5810 20" Dia. 18796 5052 451150.0 83.084.02294 6100 22" Dia. 19733 5304 473653.0 83.084.02394 6390 22" Dia. 20671 5557 496155.0 83.084.12494 6680 22" Dia. 21608 5809 518658.0 83.084.12594 6970 22" Dia. 22546 6061 541160.0 83.084.1Ratings based on 12.3% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix BL, BG, BGL, ABL, ABG, ABGL, PG, PL, and PGL and suffix WF and SF.

Power Burner, Forced Draft, Inter. Ign., Natural Gas894 2028 14" Dia. 2527 6563 1763 157580.381.2994 2320 14" Dia. 2887 7504 2017 180180.381.21094 2612 16" Dia. 3247 8450 2271 202880.381.31194 2904 16" Dia. 3608 9396 2525 225580.381.41294 3190 16" Dia. 3969 10321 2774 247780.381.41394 3480 18" Dia. 4330 11258 3026 270280.481.41494 3770 18" Dia. 4691 12196 3278 292780.481.41594 4070 18" Dia. 5052 13167 3539 316080.481.51694 4360 18" Dia. 5412 14104 3791 338580.481.51794 4650 20" Dia. 5773 15042 4043 361080.481.51894 4940 20" Dia. 6134 15979 4296 383580.581.51994 5230 20" Dia. 6495 16921 4548 406180.581.52094 5520 20" Dia. 6856 17858 4800 428680.581.52194 5810 20" Dia. 7216 18796 5052 451180.581.52294 6100 22" Dia. 7649 19733 5304 473680.581.52394 6390 22" Dia. 7938 20671 5557 496180.581.52494 6680 22" Dia. 8371 21608 5809 518680.581.52594 6970 22" Dia. 8660 22546 6061 541180.581.5Ratings based on 9.5% CO2 and +0.10" water draft at the vent.Ratings are also approved for boilers with prefix BL, BG, BGL, ABL, ABG, ABGL, PG, PL, and PGL and suffix WF and SF.

APR 2009 - 53# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 24: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

COMMERCIAL BOILERS

BoilerModel

Nameplate Input

Net I=B=R Ratings

Steam(sqft)

Gas (MBh)

Oil(gph)

Steam(MBh)

Water(MBh)

VentSize

(LxWxH)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

BoilerModel

Net I=B=R Ratings

Steam(sqft)

Steam(MBh)

Water(MBh)

GrossOutput(MBh)

CombEffy(%)

ThermalEffy(%)

Nameplate Input

Gas (MBh)

Oil(gph)

VentSize

(LxWxH)

WEIL-MCLAIN

CAST IRON

#EG Series 4 Atmospheric, Inter. Ign., Natural Gas

EG-75-PI 240 300 750 209 18075.480.0Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN, SPL, N and L.

Atmospheric, Standing Pilot, Natural or Propane GasEG-75-S 240 300 750 209 18075.480.0Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN, SPL, N and L.

Damper, Atmospheric, Inter. Ign., Natural GasEG-75-PIDN 240 300 750 209 18075.480.0Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN, SPL, N and L.

Damper, Atmospheric, Standing Pilot, Natural or Propane GasEG-75-SPD 240 300 750 209 18075.480.0Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN, SPL, N and L.

#EGH Series 4 Atmospheric, Standing Pilot, Natural or Propane Gas

EGH-85 280 350 875 243 21075.680.0EGH-95 320 400 1000 278 24075.780.0EGH-105 360 450 1125 313 27075.880.0EGH-115-PIN 400 500 1250 348 30075.980.0EGH-125-PIN 440 550 1375 383 33076.080.0

#LGB Series 2 Atmospheric, Standing Pilot, Natural or Propane Gas

LGB-4 324 400 1013 282 24378.081.0LGB-5 422 520 1317 366 31678.781.0LGB-6 527 650 1645 458 39579.181.0LGB-7 632 780 1975 549 47479.481.0LGB-8 738 910 2305 641 55379.681.0LGB-9 843 1040 2635 733 63279.781.0LGB-10 948 1170 2965 824 71179.881.0LGB-11 1053 1300 3290 916 79079.981.0LGB-12 1159 1430 3620 1007 86980.081.0LGB-13 1264 1560 3955 1099 94979.481.0LGB-14 1369 1690 4315 1190 103579.581.0LGB-15 1475 1820 4680 1282 112379.681.0LGB-16 1580 1950 5045 1373 121179.681.0LGB-17 1685 2080 5410 1465 129879.781.0LGB-18 1791 2210 5775 1557 138679.881.0LGB-19 1896 2340 6125 1648 147079.881.0LGB-20 2001 2470 6470 1740 155379.981.0LGB-21 2106 2600 6815 1831 163579.981.0LGB-22 2212 2730 7155 1923 171780.081.0LGB-23 2317 2860 7495 2014 179980.081.0

#PFG Series 6 Atmospheric, Inter. Ign., Natural Gas

PFG-6-PIN 247 305 21576.881.0PFG-7-PIN 296 366 25778.281.0Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN, SPL, N and L.

Atmospheric, Inter. Ign., Natural or Propane GasPFG-8-PIN 346 427 30179.181.0Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN, SPL, N and L.

Atmospheric, Standing Pilot, Natural or Propane GasPFG-6-SPN 247 305 21576.881.0PFG-7-SPN 296 366 25778.281.0Ratings are also approved for boilers with prefix P and Suffix P and Suffix SPN, SPL, N and L.

SGO Gold Series 3

Natural Draft, Light OilSGO-8 266 8x12x20 833 2002.30 82.785.0SGO-8W 266 8x12x20 2312.30 82.785.0SGO-9 295 8x12x20 921 2212.55 82.785.0SGO-9W 295 8x12x20 2572.55 82.785.0Ratings based on 13.0% CO2 and -0.02" water draft.Also approved with prefix P, B, or A.

WGO/WTGO Gold Series 3 Natural Draft, Light Oil

WT/WGO-8 266 8x12x20 2312.30 82.785.0WT/WGO-9 295 8x12x20 2572.55 82.785.0Ratings based on 13.0% CO2 and -0.02" water draft.Also approved with prefix P, B, or A.

APR 2009 - 54# Input, output and combustion and/or thermal efficiency are certified to efficiency test procedures specified in ANSI Z21.13

Page 25: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

APR 2009 - 92

INDEX

PAGE INDEX OF BOILER MANUFACTURERS RESIDENTIAL COMMERCIAL

CAST STAINLESS CON- IRON STEEL STEEL ALUMINUM COPPER DENSING Aerco International, Inc. ............................................... ................... ................... ................... ................... .................................... 36 Northvale, NJ American Standard Heating & Cooling Products ........ 5 Tyler, TX Axeman-Anderson Company ....................................... .................. 5 South Williamsport, PA Biasi, S.p.A./QHT, Inc. ............................................... 6 .................. ................... ................... ................... .................................... 36 Portsmouth, NH Bosch Thermotechnology Corp. .................................. 6 .................. ................... ..................6 .................. ..................6................ 36 Londonderry, NH Boyertown Furnace Co. ............................................... 7 Boyertown, PA Burnham Commercial.................................................. 7 .................. ................... ................... ................... .................................... 37 Lancaster, PA Burnham Hydronics (U.S. Boiler Co., Inc.) ............... 7 ................. 8 .................8 .................7 .................. ..................7................ 38 Lancaster, PA Camus Hydronics Ltd. .................................................. ................... ..................9 Mississauga, ON, Canada Carrier Corporation ..................................................... 9 .................. ................... ..................9 .................. ..................9 Indianapolis, IN Climate Energy, LLC ................................................... ................... ................... .................10 Medfield, MA Columbia Boiler Company ......................................... 10 ............... 11 ................. ................... ................... .................................... 38 Pottstown, PA Crown Boiler Company.............................................. 11 ................. ................... .................11 ...............13 ...............11............... 38 Philadelphia, PA Dunkirk Boilers, ECR International, Inc. ................... 13 ................. ................... .................13 ................. .................13............... 39 Utica, NY ECR International…………………………………………………………………………….14 Utica, NY EFM.............................................................................. ................. 14 Schuylkill Haven, PA Genesis Boiler Co....................................................... 15 North Bergen, NJ Hamilton Engineering…………………………………………………………...15 Livonia, MI Heat Transfer Products, Inc. ......................................... ................... .................16 ................. ................... .................16............... 39 East Freetown, MA

Page 26: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

APR 2009 - 93

INDEX

PAGE INDEX OF BOILER MANUFACTURERS (cont.) RESIDENTIAL COMMERCIAL

CAST STAINLESS CON- IRON STEEL STEEL ALUMINUM COPPER DENSING Hydrotherm, Div. of Mestek ...................................... 16 ................. ................... ................... ................... .................16................. Westfield, MA International Comfort Products Corp. (USA) ............. 16 (Arcoair, Clare, Comfort Maker, Heil, Tempstar) Lewisburg, TN Laars Heating Systems Company ................................. ................. 18 ................. ................... .................17 ...............17............... 40 Rochester, NH Lennox Industries, Inc. ............................................... 18 ................. ................... .................18 ................. .................18 Carrollton, TX Lochinvar Corporation ................................................. ................... .................19 ................. .................19 ...............19............... 40 Lebanon, TN Mestek, Inc ................................................................. 20 Westfield, MA New Yorker Boiler Company ..................................... 20 ............... 21 ................. ................... ................... .................................... 41 Hatfield, PA NY Thermal, Inc…………………………………………………………………21……………………………………21 St. John, NB, Canada PB Heat, LLC ............................................................. 21 ............... 22 ...............22 ................. ................... .................22............... 41 Bally, PA Patterson-Kelley Co./Harsco Corporation……………………………………………………………………………………………43 East Stroudsburg, PA Pennco, ECR International, Inc. ................................. 22 ................. ................... ................... ................... .................................... 43 Utica, NY PNA, Inc./Pensotti ...................................................... 23 Bangor, ME PurePro ....................................................................... 24 Boyertown, PA Raypak, Inc. ................................................................ ................... ................... ................... .................24 .................................. 44 Oxnard, CA RBI Water Heaters, Div. of Mestek Canada................. ................... ................... ................... .................24 .................................. 45 Mississauga, ON, Canada Sears Roebuck and Company ..................................... 25 ................. ................... .................25 ................. .................25 Chicago, IL Slant/Fin Corporation ................................................. 25 ................. ................... .................25 ................. .................25............... 46 Greenvale, NY Smith Cast Iron Boilers, Div. of Westcast, Inc. .......... 27 ................. ................... ................... ................... .................................... 48 Westfield, MA A.O. Smith Water Products Co. ................................... ................... ................... ................... ................... .................................... 50 Irving, TX

Page 27: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

APR 2009 - 94

INDEX

PAGE INDEX OF BOILER MANUFACTURERS (cont.) RESIDENTIAL COMMERCIAL

CAST STAINLESS CON- IRON STEEL STEEL ALUMINUM COPPER DENSING Thermal Solutions Products, LLC ................................ ................... ................... ................... ................... .................................... 51 Lancaster, PA Thermo-Dynamics Boiler Co. ...................................... ................. 29 ................. ................... ................... .................................... 51 Schuylkill Haven, PA Trane Products............................................................ 30 Tyler, TX Triangle Tube ............................................................... ................... .................30 ................. ................... .................30............... 51 Blackwood, NJ Ultimate Engineering, ECR International, Inc. .......... 30 Utica, NY Utica Boilers, ECR International, Inc. ........................ 30 ................. ................... .................30 ................. .................30............... 51 Utica, NY Utica Heating.............................................................. 31 Utica, NY Viessmann Manufacturing Co.. .................................. 31 ............... 32 ...............32 ................. ................... .................32............... 52 Waterloo, ON, Canada Weil-McLain .............................................................. 32 ................. ................... .................32 ................. .................32............... 52 Michigan City, IN Williamson Thermoflo................................................ 34 Milwaukee, WI

Page 28: Boilers Baseboard Radiation Finned Tube … Baseboard Radiation Finned Tube (Commercial) Radiation Indirect-fired Water Heaters Updated: April 2009 APR 2009 - 1 Introduction The Gas

APR 2009 - 95

INDEX

PAGE INDEX OF BASEBOARD AND FINNED TUBE MANUFACTURERS BASEBOARD FINNED TUBE Airedale • Racine, WI.......................................................................................................... ............................................................ 67

Argo Technology, Inc. • Westfield, MA............................................................................ 56

Burnham Hydronics (U.S. Boiler Co., Inc.) • Lancaster, PA............................................. 56

Crown Boiler Company • Philadelphia, PA....................................................................... 56

Design Line, Div. of Mestek, Inc. • Westfield, MA .......................................................... 56

Embassy Industries Inc. • Westfield, MA.......................................................................... 56

Governale Company, Inc. • Brooklyn, NY........................................................................ 57

Haydon Corporation, Thermogenics Div. • Paterson, NJ .................................................. 57

Hydrotherm, Div. Mestek, Inc. • Westfield, MA............................................................... 59

Modine Manufacturing Co. • Racine, WI ............................................................................ ............................................................ 67

OCS Industries, Div. of CIDC Corp. • Brooklyn, NY ....................................................... 59

Rittling, A Division of Hydro-Air Components, Inc. • Buffalo, NY ................................. ............................................................ 68

Rosemex, Inc. • St-Bruno, PQ, CANADA .......................................................................... ............................................................ 69

Sigma Convector Enclosure Corp. • Brampton, ON, Canada.............................................. ............................................................ 69

Slant/Fin Corporation • Greenvale, NY............................................................................. 59.......................................................... 69

Sterling Hydronics, Div of Mestek, Inc. • Westfield, MA................................................. 60.......................................................... 70

Suntemp, Div. of Mestek, Inc. • Westfield, MA................................................................ 62

The Trane Company • LaCrosse, WI................................................................................... ............................................................ 71

Vulcan Radiator, Div. of Mestek, Inc. • South Windsor, CT............................................... ............................................................ 73

Weil-McLain • Michigan City, IN..................................................................................... 62

PAGE INDEX OF INDIRECT- FIRED WATER HEATER MANUFACTURERS Bock Water Heaters • Madison, WI................................................................................................................................................. 79

Bradford White Corp. • Ambler, PA,................................................................................................................................................ 79

Burnham Hydronics (U.S. Boiler Co., Inc.) • Lancaster, PA............................................................................................................ 79

Crown Boiler Company • Philadelphia, PA...................................................................................................................................... 79

Heat Transfer Products, Inc • East Freetown, MA............................................................................................................................ 80

Laars Heating Systems Company. • Rochester, NH ......................................................................................................................... 80

Lochinvar Corp. • Lebanon, TN ....................................................................................................................................................... 80

PB Heat, LLC. • Bally, PA ............................................................................................................................................................... 81

Vaughn Manufacturing Corp. • Salisbury, MA ................................................................................................................................ 81

TABLES Table I - I=B=R Water Ratings ....................................................................................................................................................... 82

Table J - Flat Top Cover Steam Ratings.......................................................................................................................................... 88

Table K - Expanded Metal Cover Steam Ratings ............................................................................................................................. 90