Technical Manual

THERMflow Boiler Model

McDonald Engineers UK

November 2017

THERMflow Boiler Model Technical Manual

HOT WATER SOLUTIONS SINCE 1945

Page 2: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

1

Contents Design .................................................................................................................. 2

Preface ................................................................................................................. 2

Handling & Storage .............................................................................................. 2

What is a thermal store? ..................................................................................... 3

Basics of the Thermal Store ................................................................................. 3

Mains Water Supply ............................................................................................ 4

Water Treatment ................................................................................................. 4

THERMflow Combination General Schematic ..................................................... 5

THERMflow Cylinder General Schematic ............................................................. 6

THERMflow Connection Heights.......................................................................... 7

THERMflow with External PHE ............................................................................ 8

THERMflow Combination with PHE General Schematic ...................................... 9

THERMflow Cylinder with PHE General Schematic ........................................... 10

Commissioning................................................................................................... 11

Commissioning Best Practice ............................................................................. 12

Troubleshooting................................................................................................. 13

Schematics ......................................................................................................... 15

Ancillary Descriptions ........................................................................................ 18

Installing a Gravity System................................................................................. 20

Page 3: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

2

Design

An early adopter of the principal of domestic thermal stores, McDonald Engineers UK

first started manufacturing thermal stores in early 1990s. Manufactured by our trained

coppersmiths and designed based upon the experiences of our technical team. The

McDonald Engineers UK THERMflow provides the perfect solution to both mains

pressure hot water and space heating requirements.

Preface

The THERMflow Technical Manual should be read in conjunction with the installation

and servicing manuals issued by the manufacturer(s) of the heat source(s) used within

the thermal storage system, such as the boiler/solid fuel boiler, solar etc.

This information provided is intended to provide support with the installation of the

THERMflow storage system. Responsibility for selection and specification of our

equipment remains that of our customer and any experts or consultants concerned with

the installation(s). Our full Terms & Conditions of Sale are available on request.

The THERMflow thermal storage system is required to be fitted by a competent installer,

as defined by the relevant regulations e.g. Gas Safety Regulations. Please note that

while the THERMflow overcomes Part G Building Regulation discharge requirements

for unvented cylinders, the installation of the THERMflow may be notifiable to the

relevant building control.

Handling & Storage

It is important the THERMflow is handled with care and stored the correct way up in a

dry place at all times prior to, during and after installation. Any manual lifting will need

to comply with the requirements of the Manual Handling Operations Regulations issued

by the Health & Safety Executive. For installations on higher levels of properties such

as the 4th floor it is recommended as best practice for the THERMflow to be moved

vertically within a lift.

Page 4: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

3

What is a thermal store?

Often used in conjunction with a variety of alternative energy sources such as solid fuel,

wood burning stoves and solar, a thermal store captures input energy from heat sources

to allow that energy to be converted into mains pressure hot water and space heating

at a later time when the demand is greater. Energy from a heat source is captured within

the primary water of an open vented cylinder at a temperature of up to 80°C.

Cold water at mains pressure then passes through a High Efficiency Coil, which is

specifically designed as a heat exchanger, to draw heat from the thermal store at mains

pressure.

This heated water is subsequently blended with cold mains water through a

Thermostatically Controlled Mixing Valve, to provide mains pressure water at 55°C to

the taps. In addition, the primary water captured within the store can also be circulated

around the heating system allowing the householder to enjoy the benefits of mains

pressure water and heating produced from alternative and renewable heat sources.

Basics of the Thermal Store

The THERMflow Boiler Model utilises open vented boilers and/or Electric Immersion

Heaters as its primary heat source/s, with options available for wood burning, AGA, solid

fuel boiler and underfloor connections amongst others.

The main benefit of the Open Vented Thermal Store configuration is the open vented

nature allows the full power (kW) output of the boiler directly into the thermal store, as

no heat exchanger is required thus reducing energy usage and running costs. Input

energy from the boiler(s) is circulated from the thermal store to the central heating

system while the High Efficiency Secondary Coil is specifically designed to provide high

performance blended mains pressure hot water to the taps at 55°C.

Page 5: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

4

Mains Water Supply

The THERMflow’s performance is directly related to the cold water supply pressure and

volume incoming to the property. The THERMflow will operate with a minimum

incoming mains pressure of 1.0 Bar. A maximum incoming pressure of 3.0 Bar would be

the most optimal for performance. If the incoming mains pressure is higher than 3.0

Bar, a pressure reducing valve must be fitted downstream of where the incoming cold

supply enters the property at a lesser and appropriate pressure.

If the flow rate exceeds 20 Litres per minute at any tap, it should be restricted to

maintain the performance of the system as a whole.

Water Treatment

The THERMflow is part of the primary system and while it does not require any special

water treatment itself, the radiators and other parts of the primary circuit will require

the application of a protective scale and corrosion inhibitor such as Fernox to ensure

adequate protection. This should avoid having corrosive material in the primary system

and remove any build-up of sludge which can reduce the performance of the High

Efficiency Heat Exchanger Coil.

The volumes and concentration of inhibitor required should be calculated in accordance

with the manufacturer’s instructions. Please ensure that the thermal store volume is

also included as well as the radiator and pipework volume.

Please note that in all THERMflow models, the primary water within the thermal store

water is used as primary storage and the domestic hot water is heated instantaneously

by means of the High Efficiency Heat Exchanger Coil. Therefore, treating the primary

water will not have an effect on the domestic hot water supply.

Page 6: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

5

THERMflow Combination General Schematic

Immersion Heater

22mm Boiler Flow (Other Sizes Available)

28mm Solid Fuel Return (Other Sizes Available)

3kW

⁰C

Thermometer

22mm Central Heating Flow &

Return Connections (Other Sizes Available)

15mm Drain

Cold Mains Secondary Water c/w

Check Valve & Strainer

Hot Out c/w Thermostatic

Mixing Valve

2 Litre Expansion

Bottle

High Efficiency Secondary Coil

Maintenance Free Jetseal Ballvalve

High-Limit Stat

@ 90⁰C

Control Stat @ 75⁰C

Overflow (Not fitted as standard)

22mm Boiler Return (Other Sizes Available)

28mm Solid Fuel Flow (Other Sizes Available)

Page 7: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

6

THERMflow Cylinder General Schematic

22mm Boiler Flow (Other Sizes Available)

28mm Solid Fuel Return (Other Sizes Available)

3kW

⁰C

Thermometer

22mm Vent

22mm Central Heating Flow & Return Connections

(Other Sizes Available)

15mm Drain Immersion Heater

Cold Mains Secondary Water c/w Check Valve & Strainer

Hot Out c/w Thermostatic

Mixing Valve

22mm Cold Feed

2 Litre Expansion

Bottle

Secondary Return (Optional)

High Efficiency Secondary Coil

High-Limit Stat @ 90⁰C

Control Stat @ 75⁰C

28mm Solid Fuel Flow (Other Sizes Available)

22mm Boiler Return (Other Sizes Available)

Page 8: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

7

THERMflow Connection Heights

The connection heights shown below are taken from the ground (in mm). These

heights and the diagrams shown above are indicative of a typical arrangement of

connections, including optional extras. Bespoke options for specific installation are

available and will be supplied with a sketch prior to manufacturing of the THERMflow.

Capacity (Litres) 120 140 180 210 250 300

Shell Dimensions 900 x 450

1050 x 450

1300 x 450

1500 x 450

1500 x 500

1800 x 500

Overall Dimensions 950 x 550

1100 x 550

1350 x 550

1550 x 550

1550 x 600

1850 x 600

Cold Feed (Cyl. Only) 100 100 100 100 100 100

Drain 100 100 100 100 100 100

(3kW) IH 155 155 155 155 155 155

CH Flow 170 320 470 670 670 970

CH Return 100 100 100 100 100 100

Boiler Flow 700 850 1100 1300 1300 1600

Boiler Return 100 100 100 100 100 100

SF Flow 550 700 950 1150 1150 1450

SF Return 100 100 100 100 100 100

Thermostat 350 350 350 350 350 350

Thermometer 500 500 500 500 500 500

Hot Out 700 850 1100 1300 1300 1600

Cold In 220 370 520 720 720 1020

Page 9: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

8

THERMflow with External PHE

An External Plate Heat Exchanger (PHE) can be fitted to a THERMflow in replacement of the internal High Efficiency Coil. A THERMflow with an External PHE is an alternative to the standard thermal store, for properties with varying hot water demands. Instead of an internal High Efficiency Coil, a Plate Heat Exchanger is fitted to the external pipework of the cylinder. In areas with high corrosion or limescale, it is easier to replace the PHE as required.

The cold mains is fed through the Secondary flow of the PHE, whilst the primary water storage is pumped through the Primary flow of the PHE, allowing for instantaneously heated water. The Primary water storage flow is controlled by a Charging Pump, whilst the Secondary flow is controlled by a Flow Switch Valve. Both the Pump and Switch are controlled through a Wiring Centre, installed on the side of the cylinder.

It utilises similar heat sources (e.g. solid fuel, central heating etc.) for the primary water storage, and has a similar set up of connections to the standard thermal store combination/cylinder. However with Combination Units, a Ballvalve is not required within the Header Tank if the cylinder is a Manual Fill, and is instead replaced with an Overflow connection, as shown in the following diagram.

Page 10: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

9

THERMflow Combination with PHE General Schematic

22mm Boiler Flow (Other Sizes Available)

28mm Solid Fuel Flow (Other Sizes Available)

External Plate Heat Exchanger

3kW

⁰C

Thermometer

Overflow (Not fitted as standard)

22mm Central Heating Flow &

Return Connections (Other Sizes Available)

15mm Drain Immersion Heater

Cold Mains Secondary Water c/w Flow Switch

Charging Pump

Hot Out c/w Thermostatic

Mixing Valve

Wiring Centre

28mm Solid Fuel Return (Other Sizes Available)

22mm Boiler Return (Other Sizes Available)

High-Limit Stat @ 90⁰C

Control Stat @ 75⁰C

Maintenance Free Jetseal Ballvalve

Page 11: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

10

THERMflow Cylinder with PHE General Schematic

22mm Central Heating Flow &

Return Connections (Other Sizes Available)

15mm Drain

Cold Mains Secondary Water c/w Flow Switch

Charging Pump

Wiring Centre

22mm Cold Feed

22mm Boiler Flow (Other Sizes Available)

28mm Solid Fuel Flow (Other Sizes Available)

External Plate Heat Exchanger

22mm Vent Hot Out

c/w Thermostatic Mixing Valve

22mm Boiler Return (Other Sizes Available)

28mm Solid Fuel Return (Other Sizes Available)

3kW

⁰C

Thermometer

Immersion Heater

High-Limit Stat @90⁰C

Control Stat @75⁰C

Page 12: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

11

Commissioning

When commissioning the Boiler Model the following steps should be undertaken:

1. Connect the relevant central heating and boiler(s) flow and return pipework in accordance with the corresponding connections on the store (as indicated on the sketch provided).

2. Connect the mains to the Cold In and turn the mains on. Fit Pressure Reducing Valve

@ 3.0 Bar if required.

3. Check for leaks throughout the thermal storage system.

4. All normal procedures for a Vented Primary System apply. Drain the system, hot flush and re-fill. Add Inhibitor as required (see Water Treatment section on Page 5), re-bleed the radiators and any high points of pipework.

5. Once complete, set the Boiler Pump to its highest speed setting (usually setting 3).

Set the boiler thermostat and also the Boiler Control Thermostat on the thermal store to maximum.

6. Fire the boiler on the “Hot Water Only” setting and wait until the boiler goes off.

Turn the Boiler Control Thermostat down slowly till it clicks off, then turn it to 75°C.

(This should mean that the cylinder thermostat on the THERMflow controls the system. This can be checked by running off some hot water which should lead to the boiler re-firing)

7. Set the Solid Fuel Thermostat to ensure that the Central Heating Pump will pump in an overheat situation or if the Room Stat requests for the heating to be turned on (Normally 85 - 90⁰C).

8. Check that the hot water at the taps is at a suitable temperature for the

householder. The temperature can be increased or decreased by adjusting the factory fitted Thermostatic Mixing Valve (which will be pre-set).

9. Once complete adjust the boiler and Central Heating Pumps to provide maximum

flow rate without emitting excessive noise.

10. Finally run all taps and other hot outlets to remove all air from the system.

Page 13: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

12

Commissioning Best Practice

The below is a recommended guide of actions and checks that should be undertaken

during commissioning:-

DO

Fit an Overflow with Copper piping to the thermal store system.

Check the incoming mains water pressure, if it exceeds 3.0 bar, fit a Pressure

Reducing valve set at 3.0 bar and where the cold supply enters the property as this

will create balanced pressure throughout.

Ensure that connections are fitted in accordance with the sketch supplied.

Fill the Feed & Expansion Tank manually and adjust ball valve so water is at lowest

level.

Ensure sufficient clearance above the Feed & Expansion Tank to allow for access.

Ensure sufficient clearance for External Plate Heat Exchanger & Pipework.

Ensure that 500mm height difference is in place between the highest point of the

radiator circuit and the bottom of the Feed & Expansion Tank.

Ensure that all exposed pipework is insulated to minimalise any heat losses.

Check the boiler pump setting is set as high as possible without emitting excessive

noise to prevent a boiler temperature differential of greater than 11°C.

Leave on the power after the thermal store has been filled to prevent the central

heating and boiler pump from sticking.

DON’T

Use a combined feed and vent.

Use tube smaller than 28mm between boiler and THERMflow if the boiler exceeds

an output of 60,000 Btu (17kW) output.

Place any clothing or other combustible materials against or on the THERMflow.

Page 14: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

13

Troubleshooting

Below contains a troubleshooting and solution guide to the thermal store system. If this table does not resolve your problem, please contact either your installer or phone McDonald Engineers UK Technical Team for further advice.

SYMPTOM SOLUTION

The water at the tap is lukewarm or cold.

The thermal store is designed to work best when the store temperature is at or approaching 75°C - 80°C. While the thermal store can provide hot water at lower temperature storage, the available flow rates and volume will be reduced. Check the thermometer is showing the store temperature is at or approaching

75°C - 80C. If this is not the case, ensure that the boiler is firing and allow sufficient time for the store to reach working temperature.

The thermal store is at 80°C and the water at the taps is still lukewarm or cold

1) If the store is at or approaching 75°C - 80C, check that the Thermostatic Mixing Valve is turned to hot. The maximum

temperature of water from the Mixing Valve is 55C.

2) If the valve is turned fully to hot, check that the flow rate at any outlet (e.g. bath tap) does not exceed 20 Litres per minute. If the flow rate is above this, then turn the tap down slightly.

3) If Stage 1 and 2 has not resolved the problem a competent installer should check the mixing valve for blockages within the internal filter of the mixing valve.

Not enough hot water and less than 80°C on the thermometer.

Check the heat sources and their input in (kW) to the store as this will be lower than the kW output which will result in the store not producing enough heat for the exchanger to provide heated mains pressure water.

THERMflow is set at 80°C but the mains pressure temperature drops quickly when running a tap (e.g. bath)

1) Check with the installer that inhibitor has been put in frequently. If the DHW Coil is giving an initial heat transfer and then fading this could be a sign of sludge build up surrounding the Heat Exchanger Coil, which will reduce the performance of the store.

2) If Stage 1 does not resolve the problem, the balance of inputs and outputs may be affecting performance. This can be tested by drawing off the same flowrate of water when the output is lower, such as turning your heating off.

There is a brownish tint to the mains pressure hot water.

This could be a symptom with the heat exchanger coil leaking inside the thermal store. An installer should have this tested. If this is the case, pay attention to the Feed & Expansion Tank as the pressure within the store will increase causing the tank to overflow continually.

Page 15: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

14

Copper Feed & Expansion Tanks

The Feed & Expansion Tank (provided by the installer) must be sized correctly to

enable the expansion of the entire system volume, made up of the thermal store,

radiator and boiler circuit volumes. We recommend that the Feed & Expansion Tank

should be sized to approximately 15% capacity of the total system to cope with the

thermal expansion.

*Sizes indicated are from McDonald Engineers UK Feed & Expansion Tank Sizes

Given the high temperatures of up to

100°C that can be discharged from the

thermal store through inputs from

heat sources such as solid fuel, it is

recommended that the feed and

expansion tank is designed to

withstand temperatures over 100°C.

McDonald Engineers UK manufacture a Premium Grade Copper Feed & Expansion Tank

designed to withstand these temperatures, available as an optional extra, please

contact McDonald Engineers UK on 01592 611123 for more information.

Feed & Expansion Tank Capacity Calculator

Cylinder Capacity (Litres)

120 140 180 210 250 300

Estimated Primary Capacity

(Litres) 138 161 207 241.5 287.5 345

Recommended F&E Capacity

(Litres) 20 20 30 30 40 50

Overall Height and Diameter of F

& E Tank (mm) 400 x 420 400 x 420 375 x 470 375 x 470 470 x 470 500 x 520

½” c/w Jetseal

Maintenance Free Ball Valve & Copper Float

100mm

1” Feed

1” Overflow 1” Expansion

Page 16: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

15

Schematics

Page 17: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

16

Pump Kit Wiring Diagram

Page 18: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

17

THERMflow with External PHE, Wiring Diagram

Flow Switch Wiring Centre

Charging Pump

L

N

Mains

L

N

E

Page 19: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

18

Ancillary Descriptions

The following spare parts are available to purchase from the Website, with additional information provided. Follow the link below: https://www.mcdonald-engineers.com/spares

Expansion Vessels (WU2EV) 2 Litre Nitrogen Expansion Vessels are connected to the High Efficiency Secondary Water Coil Heat Exchanger Pipework to absorb the increase in pressure caused by thermal expansion within the Coil. When the thermal expansion occurs the internal diaphragm expands and contracts based upon the pressure set by the Expansion Vessel. For best performance it is recommend setting the Expansion Vessel to match the incoming pressure.

Low Watts Density Immersion Heaters (WIHLWD) The THERMflow are fitted with a 3kW 16” Incoloy Immersion Heater complete with Combined Control Thermostat and Resettable Safety Cut-Out. The LWD Immersion Heater is designed with reduced noise emission and a longer lifespan when used with higher temperatures and are suitable for more aggressive water conditions.

Cylinder Thermostat (WTCT) Cylinder Thermostats allow for highly responsive temperature control to your central heating, and boiler(s) by switching on and off the heat supply from the boiler(s) and to the heating. The THERMflow’s Boiler Control Stat will be used to bring the thermal store up to a maximum of 75°C- 80°C and control the boiler. The Solid Fuel Stat will be linked to the Central Heating Pump and will pump part of the contents of the THERMflow to a heat leak radiator in order to cool down the thermal store in the event of an overheat situation from an uncontrollable heat source such as solid fuel.

Thermostatic Mixing Valve (WTTMV / WTTMVS) The Thermostatic Mixing Valve blends the hot water leaving the High Efficiency Secondary Coil which can often be over 60°C with cold water to ensure constant, safe outlet temperatures at 55°C to prevent scalding.

WTTMV

WTTMVS

Page 20: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

19

Thermometer (WTHERM) The 2” Side Entry Thermometer allows for a temperature reading of the thermal store to be taken from the side of thermal store to ensure the thermal store is operating at the correct temperature.

Thermal Store Pump (WTP) Designed with a three-speed motor to circulate round domestic heating systems, the thermal store pump are designed to pump to the central heating and boilers of domestic central heating systems of up to 35kW.

THERMflow Programmer (WTPROG) The THERMflow programmer allows you to set “On” and “Off” time periods to switch the central heating on and off to suit the user’s requirements.

THERMflow Wiring Centre (WTWC) Acting as the relay for the wiring cables from the programmer, boiler, pumps and stats to ensure the thermal store operates correctly.

Pressure Reducing Valve (WUVPRC) Designed to regulate the incoming mains pressure to a fixed pressure.

Plate Heat Exchanger (WTPHE) Exchanges hot water temperature from cylinder with secondary flow. Insulation is included. Flow rates must be specified when ordering. (Only for THERMflow models with External PHE).

Page 21: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

20

Installing a Gravity System

In absence of recommendations from the solid fuel boiler manufacturer as to the best

layout, McDonald Engineers UK would advise the following layout would be most

suitable to achieve the best performance from a gravity circulation layout, key points to

follow are:-

o Ensure the heat source is below the cylinder which gives the layout a good system

height

o Gravity pipework to be 28mm diameter or larger

o Avoid long horizontal runs aim for a ratio of 20:80 minimum between horizontal

and vertical

Page 22: Boiler Model Technical Manual - McDonald Engineers · THERMflow Boiler Model Technical Manual ... Schematics ... Set the Solid Fuel Thermostat to ensure that the Central Heating Pump

Hot Water Solutions Since 1945

The HWA Charter Statement requires that all members adhere to the

following:

To supply fit for purpose products clearly and honestly described

To supply products that meet or exceed appropriate standards and

building and water regulations

To provide pre and post technical support

To provide clear and concise warranty details to customers