BOBBITT MAKE-UP AIR
DRAWING INDEXDRAWING TITLESHEET
T001 TITLE SHEETMECHANICAL LEGENDS, NOTES & SCHEDULESM001HUNTER SQUARE MECHANICAL DEMOLITION PLANMD101
VICINITY MAP
MECHANICAL CONTROL DIAGRAMSMECHANICAL DETAILS
E001
M301
BOBBITT MECHANICAL DEMOLITION PLANSMD102HUNTER SQUARE MECHANICAL NEW WORK PLANM101BOBBITT MECHANICAL NEW WORK PLANSM102
MECHANICAL CONTROL DIAGRAMS
ED101ELECTRICAL LEGENDS, NOTES & SCHEDULES
ED102HUNTER SQUARE ELECTRICAL DEMOLITION PLAN
E101BOBBITT ELECTRICAL DEMOLITION PLANS
E102HUNTER SQUARE ELECTRICAL NEW WORK PLAN
PREPARED BY:
ROACH CONSULTING ENGINEERS, P.C.
AND HUNTER SQUARE CHILLER REPLACEMENT
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
M302
BOBBITT ELECTRICAL NEW WORK PLANS
T001
TITL
E SH
EET
BOBBITT
HUNTER SQUARE
LOCATION MAP LOCATION MAP
M201
HUNTER SQUARE825 GOFF ST.NORFOLK, VA 23504
BOBBITT5920 POPLAR HALL DR.NORFOLK, VA 23502
EQUIPMENT DESIGNATION LEGEND
AIR COOLED CONDENSER
AIR HANDLING UNIT
WATER-COOLED CHILLER SCHEDULE
MAKE-UP AIR UNIT
PUMP DESIGNATION
UNIT HEATER
ACC-1
AHU-1
C-1
MUA-1
PA-12
UH
DEMOLITION NOTE
NEW WORK NOTE
SUPPLY DUCT UP/DOWN
POINT OF DISCONNECTION
POINT OF CONNECTION
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
CHILLED WATER SUPPLY
CHILLED WATER RETURN
HOT WATER SUPPLY
HOT WATER RETURN
REFRIGERANT PIPING
FLOW DIRECTION ARROW
EXISTING DUCT SIZE
ELBOW WITH TURNING VANES
SMOKE DETECTOR
3 WAY CONTROL VALVE
GATE VALVE
THERMOMETER
FLOOR DRAIN
BACKFLOW PREVENTER
REFRIGERANT MONITOR
BALANCING VALVE
UNION
VENTURI BALANCING VALVE
MANUAL AIR VENT
PRESSURE TEMPERATURE PORT
Y-STRAINER
HVAC LEGEND
GENERAL ABBREVIATIONS
AIR VENT
BRITISH THERMAL UNITS
PER HOUR
CUBIC FEET PER MINUTE
CHILLED WATER
DRY BULB
DIRECT DIGITAL CONTROL
ENTERING AIR TEMPERATURE
ENTERING WATER
TEMPERATURE
EXISTING TO REMAIN
EXTERNAL STATIC PRESSURE
DEGREES FARENHEIT
FULL LOAD AMPS
FEET
GALLONS PER MINUTE
INCHES
KILOWATT
LEAVING AIR TEMPERATURE
A/V
BTUH
CFM
CHW
DB
DDC
EAT
EWT
ETR
ESP
°F
FLA
FT
GPM
IN
KW
LAT
1. MECHANICAL WORK SHALL CONFORM WITH THE 2012 VIRGINIA UNIFORM
STATEWIDE BUILDING CODE (VUSBC). ALL EQUIPMENT AND INSTALLATION
METHODS SHALL CONFORM.
2. DUCT DIMENSIONS MAY BE MODIFIED AS APPROVED BY ENGINEER.
3. SEAL AROUND AND MAKE AIRTIGHT ALL DUCTS AND PIPES PENETRATING
INSULATED CEILINGS, WALLS AND FLOORS.
4. CONTRACTOR SHALL VERIFY REFRIGERANT PIPE SIZES WITH EQUIPMENT
MANUFACTURER FOR THE INDICATED INSTALLATION.
5. VALVES AND SPECIALTIES SHALL BE LINE SIZE EXCEPT FOR CONTROL
VALVES OR UNLESS NOTED OTHERWISE.
6. CORRECT SETTING ON BALANCING FITTINGS SHALL BE PERMANENTLY
MARKED.
7. PROVIDE MANUAL AIR VENTS AT HIGH POINTS OF HYDRONIC SYSTEMS.
8. PROVIDE 1/2" DRAIN VALVES AND CAPPED CONNECTIONS AT LOW POINTS IN
PIPING SYSTEMS FOR DRAINING.
9. EXAMINE MANUFACTURER'S LITERATURE TO DETERMINE RECOMMENDED
CLEARANCES, THESE CLEARANCES SHALL BE ESTABLISHED AND
MAINTAINED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING THESE REQUIREMENTS WITH ALL OTHER TRADES.
GENERAL MECHANICAL NOTES
1
LWT
MAX
MBH
MCA
MOCP
MIN
NO.
OA
PD
REFRIG
RLA
SENS
TEMP
VFD
WB
WG
WPD
ZHC
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTUH
MINIMUM CIRCUIT AMPS
MAXIMUM OVERCURRENT
PROTECTION
MINIMUM
NUMBER
OUTSIDE AIR
PRESSURE DROP
REFRIGERATION
RATED LOADED AMPS
SENSIBLE
TEMPERATURE
VARIABLE FREQUENCY DRIVE
WET BULB
WATER GUAGE
WATER PRESSURE DROP
ZONE HEATING COIL
1
INDICATES EXISTING TO BE DEMOLISHED
INDICATES EXISTING TO REMAIN
INDICATES NEW WORK
LINE TYPE LEGEND
1. CONTRACTOR SHALL VISIT JOB SITE TO DETERMINE EXTENT OF WORK
INVOLVED PRIOR TO BIDDING THE PROJECT.
2. WHERE DUCTWORK IS INDICATED TO BE REMOVED, IT SHALL MEAN
COMPLETE REMOVAL OF DUCTWORK, INCLUDING FITTINGS, INSULATION,
SUPPORTS, BRACKETS, CONTROLS, AND INCIDENTAL ITEMS CONNECTED OR
FASTENED TO THE DUCTWORK. DUCTWORK IS DIAGRAMMATIC AND
INDICATES THE GENERAL EXTENT OF WORK. NO ATTEMPT IS MADE TO SHOW
EVERY ELL, TEE, OFFSET AND FITTING. REMOVE DUCTWORK AS INDICATED
AND SPECIFIED.
GENERAL DEMOLITION NOTES
CWS
CWR
CHWS
CHWR
FD
SD
(X" x X")
RS/RL
HWS
HWR
BFP
RM
PT
T
NRHA HAS AN EXISTING WEB BASED BACNET ENTERPRISE DDC CONTROL
SYSTEM IN OPERATION CONNECTED TO MULTIPLE NRHA BOILER PLANT
FACILITIES. IT IS AN AUTOMATED LOGIC (ALC) WEBCTRL SYSTEM. THE FRONT
-END WEB SERVER AND APPLICATION SOFTWARE IS LOCATED AT THE 910
BALLENTINE FACILITY. NETWORK SECURITY IS COORDINATED WITH THE
NRHA IT DEPARTMENT AND FIREWALL VPN PROTECTION FOR THE NRHA
WIDE AREA NETWORK IS MAINTAINED TO ALLOW THE STAND-ALONE REMOTE
BOILER PLANTS TO COMMUNICATE SEAMLESSLY TO THE ALC WEBCTRL
SERVER. THE ALC SYSTEM IS SERVICED MONTHLY AND OPERATIONALLY
MAINTAINED BY THERMO-TROL SYSTEMS OF VIRGINIA BEACH.
THE CONTRACTOR WILL BE RESPONSIBLE FOR INCLUDING IN THEIR PRICE
THE SERVICES OF THERMO-TROL SYSTEMS TO PERFORM THE CONTROL
PORTION OF THE SCOPE OF WORK. ADDITIONALLY IT IS THE RESPONSIBILITY
OF THE CONTRACTOR TO COORDINATE THE DEMOLITION OF CONTROLS AND
INSTALLATION OF CONTROLS WITH THERMO-TROL SYSTEMS TO ENSURE
THAT THE EQUIPMENT CONTROLS REMAIN OPERATIONAL DURING THE
RENOVATION AND DOWNTIME IS MINIMIZED. WORK SHALL NOT AFFECT THE
OPERATION OF THE OTHER EQUIPMENT MONITORED AND CONTROLLED BY
THE AUTOMATED LOGIC WEBCTRL SYSTEM.
CONTROLS SCOPE OF WORK ALLOWANCE IS LISTED ON THE BID FORM.
CONTACT DARYL BEASLEY OF THERMO-TROL SYSTEMS (757-428-4646) FOR
COORDINATION.
THE SCOPE OF WORK ALLOWANCE ALSO INCLUDES THE REFRIGERANT
MONITORING SYSTEM.
DDC CONTROLS NOTE
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
M001
MEC
HA
NIC
AL
LEG
END
S, N
OTE
S A
ND
SC
HED
ULE
S
REMOVE 80 TON CHILLER COMPLETE. RECOVER REFRIGERANT AND DISPOSE OF
ACCORDINGLY.
REMOVE 6" CONDENSOR WATER SUPPLY AND RETURN PIPING TO POINT INDICATED.
REMOVE 6" CHILLED WATER SUPPLY AND RETURN PIPING TO POINT INDICATED.
REMOVE REFRIGERANT MONITORING SYSTEM.
REMOVE CONDENSER WATER PUMP PA-12 AND STORE FOR REINSTALLATION.
PERFORM PRETEST AND BALANCE ON CHILLER, COOLING TOWER, CONDENSER
WATER PUMP, AND CHILLED WATER PUMP. REPORT FLOWS AT MAXIMUM, MINIMUM
AND TEMPERATURES TO ENGINEER. REPORT ANY CONCERNS TO ENGINEER ABOUT
BRINGING ENTIRE SYSTEM BACK UP TO FULL OPERATION.
REMOVE FLOW SENSOR.
1
DEMOLITION NOTES THIS SHEET
2
1
3
2
2
3
PA-12 VFD,
ETR
PA-12
PURGE FAN, ETR
CHEMICAL FEED, ETR
HUNTER SQUARE MECHANICAL ROOM - MECHANICAL DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
COOLING TOWER, ETR
CIRCULATION FAN, ETR
FD
VFD
INCOMING
DOMESTIC WATER
EXISTING GATE IN BRICK
WALL (ACCESS FOR
CHILLER REMOVAL)
EXISTING ROLL-UP DOOR
4
5
5
3
4
1/4" = 1'-0"
5' 0 5' 10'
6
6
CH
WS
CH
WR
CWR
CWS
GRAPHIC SCALE
AREA OF WORK
KEYPLAN
NO SCALE
EXISTING EQUIPMENT PAD
BFP
DOMESTIC WATER
MAKEUP LINE, ETR
CHW PUMPS, ETR
REFRIGERANT MONITOR3
6
6
A/V
7
7
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
MD101
HU
NTE
R S
QU
AR
E M
ECH
AN
ICA
L D
EMO
LITI
ON
PLA
N
NOTES THIS SHEET
REMOVE DEDICATED OUTSIDE AIR UNIT COMPLETE. DISCONNECT UNIT FROM LOUVER.
REMOVE DUCTWORK TO POINT INDICATED.
REMOVE RS/RL PIPING COMPLETE.
REMOVE HWS/HWR TO POINT INDICATED.
PERFORM PRETEST AND BALANCE ON AIR FLOW AND HOT WATER FLOW.
REMOVE AIR COOLED CONDENSING UNIT.
REMOVE UNDERGROUND REFRIGERANT PIPING COMPLETE, MAINTAIN PATH FOR NEW REFRIGERANT
PIPING.
DOMESTIC HOT WATER RECIRCULATION LINE RUNS NEAR UNIT IF REMOVAL IS REQUIRED FOR
INSTALLATION OF MUA-1 COORDINATE OUTAGE WITH NRHA.
REMOVE 1" DRAIN PIPE TO POINT INDICATED.
1
BOBBITT FIRST FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
(24x18)
(1
8x8
)
(6x18)
2-1/2" CHS
(2
6x1
2)
54x30 OUTSIDE AIR
INTAKE LOUVER
(18x18)
(32x8)
(10x12)
(12x12)
(16x12)
ZHC, ETR
MUA-1
S
D
ZHC, ETR
5
2
3
4
2
2
4
4
FOR CONTINUATION
SEE SITE PLAN
DOMESTIC WATER
TANK, ETR LOCATED
BELOW UNIT.
1
MD102 MD102
5
6
7
1
1/4" = 1'-0"
5' 0 5' 10'
ZHC, ETR
EXISTING
DUCT UP
8
9
3
9
1"
BOBBITT SITE MECHANICAL PLAN
SCALE: 1" = 10'-0"
1
MD102 MD102
7
6
1" = 10'-0"
10' 5' 0 10' 20' 30'
GRAPHIC SCALE
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
MD102
BO
BB
ITT
MEC
HA
NIC
AL
DEM
OLI
TIO
N P
LAN
S
PA-12 VFD, ETR
PURGE FAN, ETR
CHEMICAL FEED, ETR
COOLING TOWER, ETR
CIRCULATION FAN, ETR
FD
VFD
INCOMING
DOMESTIC WATER
EXISTING ROLL-UP DOOR
1/4" = 1'-0"
5' 0 5' 10'
PROVIDE CHILLER AND SUPPORTS COMPLETE. PROVIDE MANUFACTURER
RECOMMENDED.
PROVIDE INSULATED CHWS & CHWR PIPING COMPLETE. PAINT PIPE TO MATCH
EXISTING COLOR CONVENTION. CONTRACTOR TO VERIFY SIZE PRIOR TO
INSTALLATION.
PROVIDE CWS & CWR PIPING, INSULATION, HANGERS AND SUPPORTS COMPLETE.
PAINT PIPE TO MATCH EXISTING COLOR CONVENTION. CONTRACTOR TO VERIFY SIZE
PRIOR TO INSTALLATION.
INSTALL STORED PUMP, PA-12, IN NEW LOCATION TO PROVIDE SPACE TO SERVICE
CHILLER. REFER TO PUMP INSTALLATION DETAIL.
PROVIDE AND INSTALL SINGLE ZONE REFRIGERANT MONITOR.
PROVIDE AND INSTALL COMBINATION HORN/STROBE ALARM ABOVE REFRIGERANT
MONITOR.
PROVIDE AND ROUTE TUBING FROM THE MONITOR TO A SAMPLE LOCATION NEAR
THE CHILLER. TERMINATE 12" AFF.
PROVIDE AND ROUTE TUBING FROM THE MONITOR TO A REFERENCE LOCATION
EXTERIOR TO THE ROOM, TERMINATE AT LEAST 8 FEET AFF. PROVIDE WEATHER
PROTECTION SHIELD.
MAINTAIN CONNECTIONS OF CHEMICAL FEED SYSTEM TO EXISTING PIPE. IF
CONNECTIONS ARE DEMOLISHED, CONTRACTOR SHALL INSTALL TO MAINTAIN
OPERATION OF CHEMICAL FEED SYSTEM.
FILL SYSTEM AND MAINTAIN CHEMICAL LEVELS TO ESTABLISHED STANDARDS.
CHEMICALS SHOULD BE PURCHASED FROM CHEMTREAT, INC; 10040 LICKINGHOLD
ROAD, ASHLAND, VIRGINIA 23005, 1-804-935-2000. CONTRACTOR SHALL SHOCK TOWER
AS REQUIRED TO BRING ENTIRE SYSTEM UP TO OPERATIONAL LIMITS.
PROVIDE FLOW STATION.
TIE EXISTING PURGE FAN IN WITH NEW REFRIGERANT MONITORING SYSTEM.
1
NEW WORK NOTES THIS SHEET
2
3
SIEMENS CONTROL
PANEL, ETR
1
2
3
HUNTER SQUARE MECHANICAL ROOM - MECHANICAL NEW WORK PLAN
SCALE: 1/4" = 1'-0"
CH
WS
CH
WR
CWR
CWS
AREA OF WORK
KEYPLAN
NO SCALE
GRAPHIC SCALE
4
5
6
7
8
9
RM
65
7
8
9
BFP
DOMESTIC WATER
MAKEUP LINE, ETR
CHW PUMPS, ETR
4
10
10
10
A/V
, E
TR
CHWS
CHWR
6"
6"
11
11
12
12
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
M101
HU
NTE
R S
QU
AR
E M
ECH
AN
ICA
L N
EW W
OR
K P
LAN
NOTES THIS SHEET
PROVIDE 100% OUTSIDE AIR UNIT ON VIBRATION ISOLATION HANGERS. PROVIDE FLEXIBLE CONNECTORS
TO DUCTWORK. EXTEND UNISTRUT TO HANG UNIT SECURELY. CONTRACTOR SHALL FIELD COORDINATE
CONNECTIONS TO EXISTING DUCT. VERIFY ALL DUCT SIZES.
PROVIDE DUCT TRANSITION TO EXISTING DUCTWORK.
PROVIDE RS/RL PIPING, INSULATION, HANGERS, AND SUPPORTS.
PROVIDE HWS/R, INSULATION, PIPING, HANGERS AND SUPPORTS.
PROVIDE UNDERGROUND ENCASED RS/RL PIPING. SEE DETAIL ON M201.
PROVIDE CONDENSING UNIT.
PROVIDE CONDENSATE DRAIN. CONNECT TO EXISTING.
1
BOBBITT FIRST FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
(24x18)
(1
8x8
)
(6x18)
2-1/2" CHS
(2
6x1
2)
(18x18)
(32x8)
(10x12)(12x12)
(16x12)
ZHC-3
MUA-1
ZHC-2
FOR CONTINUATION
SEE SITE PLAN
DOMESTIC WATER
TANK, ETR LOCATED
BELOW UNIT.
1
M102 M102
1/4" = 1'-0"
5' 0 5' 10'
S
D
2
3
4
5
6
2
2
3
1
4
PROVIDE SCHEDULE 40 PVC WITH LONG SWEEP TEE FOR EACH OF THE THREE PIPES REQUIRED.
TRENCH SHALL BE PARTIALLY BACK FILLED WITH PEA GRAVEL, NOTHING LARGER THAN 6" IN DIAMETER.
NO WHEELED OR TRACKED VEHICLES SHALL BE USED FOR TAMPING.
ALL REFRIGERANT PIPING MUST PASS THE LEAK TEST AND BE VACUUMED CLEANED PRIOR TO BEING
BACKFILLED.
PVC SHALL BE BROUGHT MIN OF 8" ABOVE GRADE PRIOT TO TERMINATION. INSTALL A WATERTIGHT
ENCLOSURE OVER REFRIGERANT LINES AT POINT OF ENTRY.
BURIED REFRIGERANT PIPING NOTE
7
7
1"
1-1/2"
BOBBITT SITE MECHANICAL PLAN
SCALE: 1" = 10'-0"
ACCU-1
1" = 10'-0"
10' 5' 0 10' 20' 30'
GRAPHIC SCALE
5
6
1
M102 M102
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
M102
BO
BB
ITT
MEC
HA
NIC
AL
NEW
WO
RK
PLA
NS
AHU INSTALLATION DETAIL
SUPPLY AIR DUCT
MOUNT HIGH ENOUGH
FOR CONDENSATE
DRAIN TO SLOPE
D
RL
RS
CEILING
3/8" THREADED ROD
(TYP. OF 4)
VIBRATION ISOLATOR
(TYP OF 4)
FIL
TE
R
FLEX CONNECTION
AUXILIARY DRAIN PAN, EXTEND 3"
ON ALL SIDES OF UNIT, PROVIDE
FLOAT SWITCH
NOT TO SCALE
CIRCULATING PUMP CONNECTIONS DETAIL
SUCTION DIFFUSER
PRESSURE GAUGE
THERMOMETER (TYP.)
GATE VALVE (TYP.)
FLEXIBLE CONNECTOR (TYP.)
VERTICAL LIFT CHECK VALVE
CONCENTRIC REDUCER
COUPLING GUARD
PUMP
PUMP BASE
MOTOR
BLOW-OFF
SUPPORT
EXISTING PAD
NOT TO SCALE
VALVE
T
T
PT
PT
NOT TO SCALE
HOT WATER COIL PIPING DIAGRAM
HWR
HWS
3-WAY CONTROL VALVEBALANCING
BALANCING VALVE
3/4" DRAIN VALVE
WITH HOSE FITTING
MANUAL AIR VENT
VENTURI
NOTE: ARRANGE PIPING TO PERMIT REMOVAL OF COIL IN AHU.
FLOW STATION DETAIL
TRANSMITTER, DIERIECH MOD. 2000CX
OR EQUAL 4-20ma OUTPUT, 24VDC INPUT
ANNUBAR OR EQUAL
FLOW SENSOR ANNUBAR
OR EQUAL
CHWR
MIN. 42" STRAIGHT MIN. 24" STRAIGHT
MOUNTING BRACKET
NOT TO SCALE
AHU CONDENSATE TRAP DETAIL
AUXILIARY DRAIN PAN, EXTEND 3"
ON ALL SIDES OF UNIT. PROVIDE
WITH FLOAT SWITCH
3/4" SCHEDULE 40 PVC, SEE
PLUMBING PLANS FOR
LOCATIONS
CLEAN OUT
AIR HANDLING UNIT
NOT TO SCALE
UNDERGROUND PIPING DETAIL
NOT TO SCALE
PVC SCHEDULE 40 PIPE
REFRIGERANT GAS
PIPE
INSULATION MATERIAL
FINISHING TAPE
PVC SCHEDULE 40 PIPE
4"
REFRIGERANT LIQUID
PIPE
4"
12"
BEDDING SOIL
NATIVE BACKFILL
NOTE: PUMP IS EXISTING. ALL VALVE WORK TO PUMP AND PIPING IS NEW.
BUTTERFLY VALVE (TYP.)
PRESSURE GAUGE
TEMPERATURE TRANSMITTER (TYP.)
THERMOMETER (TYP.)
3/4" BALL VALVE W/HOSE
CONNECTION AND CAP (TYP.)
FLANGE (TYP.)
CONDENSER
EVAPORATOR
STAINLESS STEEL
SPARE WELL (TYP.)
RELIEF VALVE SET AT 150 PSI
PIPE TO DISCHARGE TO DRAIN
DIFFERENTIAL PRESSURE
SWITCH (TYP.)
MOUNTING CONTROL
VALVE (TYP.)
CWS
CWR
DPS
1" BALL VALVE WITH
THREADED CAP (TYP. 4)
1. SPECIFY FIELD FABRICATED, REMOVABLE
AND REUSEABLE INSULATION BOXES ON
EVAPORATOR MACHINE BOX HEADS.
2. ROUTE REFRIGERANT RELIEF VALVES TO
EXTERIOR OF BUILDING.
3. INDICATE DRAINS ON BOTTOM OF HEAT
EXCHANGER HEADS/MARINE WATER BOXES,
EACH END.
NOTES:
DPS
CHWR
CHWS
TT
TT
TT
WATER-COOLED CHILLER PIPING DIAGRAM
NOT TO SCALE
SEED ALL AREAS DISTURBED BY
DEMOLITION AND NEW WORK
ELECTRICAL AND
CONTROL WIRING
INSULATION MATERIAL
4"
PEA GRAVEL BACKFILL
OUTSIDE
AIR DUCT
4"
FLOW MEASURING
DEVICE (TYP.)
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
M201
MEC
HA
NIC
AL
DET
AIL
S
CHILLED WATER BYPASS VALVE
CHILLED WATER ISOLATION VALVE
CHILLER
LOCAL DDC CONTROLLER
CHILLED WATER ISOLATION VALVE STATUS
AN
ALO
G
DIG
IT
AL
D01
OUTPUTS
A01
DIG
IT
AL
DI1
DI2
AN
ALO
G
AI1
INPUTS
CHILLED WATER FLOW
DI3
AI2CHILLED WATER RETURN TEMP
AI3CHILLED WATER SUPPLY TEMP
CONDENSER WATER PUMP STATUSDI4
CHILLER STATUS
CHILLED WATER PUMP STATUS
AI4CONDENSER WATER RETURN TEMP
DI5
AI5CONDENSER WATER SUPPLY TEMP
CHILLED WATER PUMP START/STOPD02
CHILLER ENABLED03
CONDENSER WATER PUMP START/STOPD04AI6
CHILLED WATER FLOW SETPOINT
DI6
EMERGENCY SHUTDOWN
REFRIGERANT LEAK SHUTDOWN
CHILLED WATER SYSTEM CONTROL DIAGRAM, POINTS LIST, AND SEQUENCE OF OPERATION
NO SCALE
M
CT
Starter
CWS
CWR
T
T
T
T
R
Chiller
CHWR
M
CT
Starter
CHWS
S
AI7OUTSIDE AIR TEMP
DI5
D01
DI1
D02
DI2
AI1
AI2
DI6
DI3
D03
AI3
AI4
AI5
DI4
D04
1. SINGLE WATER COOLED CHILLER (TYPICAL OF 1)
CHILLER - RUN CONDITIONS:
THE CHILLER SHALL BE ENABLED TO RUN WHENEVER:
• A DEFINABLE NUMBER OF CHILLED WATER COILS NEED COOLING
• AND THE OUTSIDE AIR TEMPERATURE IS GREATER THAN 54°F (ADJ.).
TO PREVENT SHORT CYCLING, THE CHILLER SHALL RUN FOR AND BE OFF FOR
MINIMUM ADJUSTABLE TIMES (BOTH USER DEFINABLE), UNLESS SHUTDOWN ON
SAFETIES OR OUTSIDE AIR CONDITIONS.
THE CHILLER SHALL RUN SUBJECT TO ITS OWN INTERNAL SAFETIES AND
CONTROLS.
EMERGENCY SHUTDOWN:
THE CHILLER SHALL SHUT DOWN AND AN ALARM GENERATED UPON RECEIVING
AN EMERGENCY SHUTDOWN SIGNAL STATUS.
REFRIGERANT DETECTION:
THE CHILLER SHALL SHUT DOWN AND AN ALARM GENERATED UPON RECEIVING
A REFRIGERANT LEAK DETECTION STATUS.T HE EXISTING PURGE FAN SHALL
ENGAGE UPON DETECTION OF REFRIGERANT AT LOW SPEED. UPON INCREASE
IN REFRIGERANT DETECTED THE PURGE FAN SHALL OPERATE AT HIGH SPEED.
CHILLED WATER ISOLATION VALVE:
THE CHILLED WATER ISOLATION VALVE SHALL OPEN ANYTIME THE CHILLER IS
CALLED TO RUN. THE CHILLED WATER ISOLATION VALVE SHALL ALSO OPEN
WHENEVER THE CHILLED WATER PUMP RUNS FOR FREEZE PROTECTION.
THE CHILLED WATER ISOLATION VALVE SHALL OPEN PRIOR TO THE
CHILLER BEING ENABLED AND SHALL CLOSE ONLY AFTER THE CHILLER IS
DISABLED. THE CHILLED WATER ISOLATION VALVE SHALL THEREFORE HAVE:
• A USER ADJUSTABLE DELAY ON START.
• AND A USER ADJUSTABLE DELAY ON STOP.
THE DELAY TIMES SHALL BE SET APPROPRIATELY TO ALLOW FOR ORDERLY
CHILLED WATER SYSTEM START-UP, SHUTDOWN AND SEQUENCING.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• CHILLED WATER ISOLATION VALVE FAILURE: VALVE COMMANDED OPEN
BUT THE STATUS INDICATES CLOSED.
• CHILLED WATER ISOLATION VALVE OPEN IN HAND: VALVE COMMANDED
CLOSED BUT THE STATUS INDICATES OPEN.
• CHILLED WATER ISOLATION VALVE RUNTIME EXCEEDED: VALVE STATUS
RUNTIME EXCEEDS A USER-DEFINABLE LIMIT.
CHILLED WATER PUMP:
THE CHILLED WATER PUMP SHALL RUN ANYTIME THE CHILLER IS CALLED TO
RUN. THE CHILLED WATER PUMP SHALL ALSO RUN FOR FREEZE PROTECTION
WHENEVER THE OUTSIDE AIR TEMPERATURE IS LESS THAN A USER
DEFINABLE SETPOINT (ADJ.).
THE CHILLED WATER PUMP SHALL START PRIOR TO THE CHILLER BEING
ENABLED AND SHALL STOP ONLY AFTER THE CHILLER IS DISABLED. THE
CHILLED WATER PUMP SHALL THEREFORE HAVE:
• A USER ADJUSTABLE DELAY ON START.
• AND A USER ADJUSTABLE DELAY ON STOP.
THE DELAY TIMES SHALL BE SET APPROPRIATELY TO ALLOW FOR ORDERLY
CHILLED WATER SYSTEM START-UP, SHUTDOWN AND SEQUENCING.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• CHILLED WATER PUMP FAILURE: COMMANDED ON, BUT THE STATUS IS
OFF.
• CHILLED WATER PUMP RUNNING IN HAND: COMMANDED OFF, BUT THE
STATUS IS ON.
• CHILLED WATER PUMP RUNTIME EXCEEDED: STATUS RUNTIME
EXCEEDS A USER DEFINABLE LIMIT.
CHILLED WATER BYPASS VALVE - MINIMUM FLOW CONTROL:
THE CONTROLLER SHALL MEASURE CHILLED WATER FLOW THROUGH THE
CHILLER AND, AS THE CHILLED WATER FLOW DROPS BELOW SETPOINT, THE
CONTROLLER SHALL MODULATE THE CHILLED WATER BYPASS VALVE OPEN TO
MAINTAIN THE MINIMUM CHILLED WATER FLOW SETPOINT.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• LOW CHILLED WATER FLOW: IF THE CHILLED WATER FLOW IS 25% LESS
THAN SETPOINT.
CONDENSER WATER PUMP:
THE CONDENSER WATER PUMP SHALL RUN ANYTIME THE CHILLER IS CALLED TO
RUN.
THE CONDENSER WATER PUMP SHALL START PRIOR TO THE CHILLER BEING
ENABLED AND SHALL STOP ONLY AFTER THE CHILLER IS DISABLED. THE
CONDENSER WATER PUMP SHALL THEREFORE HAVE:
• A USER ADJUSTABLE DELAY ON START.
• AND A USER ADJUSTABLE DELAY ON STOP.
THE DELAY TIMES SHALL BE SET APPROPRIATELY TO ALLOW FOR ORDERLY
CHILLED WATER SYSTEM START-UP, SHUTDOWN AND SEQUENCING.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• CONDENSER WATER PUMP FAILURE: COMMANDED ON, BUT THE STATUS
IS OFF.
• CONDENSER WATER PUMP RUNNING IN HAND: COMMANDED OFF, BUT
THE STATUS IS ON.
• CONDENSER WATER PUMP RUNTIME EXCEEDED: STATUS RUNTIME
EXCEEDS A USER DEFINABLE LIMIT.
CHILLER:
THE CHILLER SHALL BE ENABLED A USER ADJUSTABLE TIME AFTER PUMP
STATUSES ARE PROVEN ON. THE CHILLER SHALL THEREFORE HAVE A
USER ADJUSTABLE DELAY ON START.
THE DELAY TIME SHALL BE SET APPROPRIATELY TO ALLOW FOR ORDERLY
CHILLED WATER SYSTEM START-UP, SHUTDOWN AND SEQUENCING.
THE CHILLER SHALL RUN SUBJECT TO ITS OWN INTERNAL SAFETIES AND
CONTROLS.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• CHILLER FAILURE: COMMANDED ON, BUT THE STATUS IS OFF.
• CHILLER RUNNING IN HAND: COMMANDED OFF, BUT THE STATUS IS ON.
• CHILLER RUNTIME EXCEEDED: STATUS RUNTIME EXCEEDS A USER
DEFINABLE LIMIT.
CHILLER CHILLED WATER SUPPLY SETPOINT:
THE CHILLER SHALL MAINTAIN A CHILLED WATER SUPPLY
TEMPERATURE SETPOINT AS DETERMINED BY ITS OWN INTERNAL CONTROLS
(PROVIDED BY OTHERS).
CHILLED WATER TEMPERATURE MONITORING:
THE FOLLOWING TEMPERATURES SHALL BE MONITORED:
• CHILLED WATER SUPPLY.
• CHILLED WATER RETURN.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• HIGH CHILLED WATER SUPPLY TEMP: IF THE CHILLED WATER SUPPLY
TEMPERATURE IS GREATER THAN 55°F (ADJ.).
• LOW CHILLED WATER SUPPLY TEMP: IF THE CHILLED WATER SUPPLY
TEMPERATURE IS LESS THAN 38°F (ADJ.).
CONDENSER WATER TEMPERATURE MONITORING:
THE FOLLOWING TEMPERATURES SHALL BE MONITORED:
• CONDENSER WATER SUPPLY TEMPERATURE.
• CONDENSER WATER RETURN TEMPERATURE.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• HIGH CONDENSER WATER SUPPLY TEMP: IF THE CONDENSER WATER
SUPPLY TEMPERATURE IS GREATER THAN 86°F (ADJ.).
• LOW CONDENSER WATER SUPPLY TEMP: IF THE CONDENSER WATER
SUPPLY TEMPERATURE IS LESS THAN 65°F (ADJ.).
• HIGH CONDENSER WATER RETURN TEMP: IF THE CONDENSER WATER
RETURN TEMPERATURE IS GREATER THAN 100°F (ADJ.).
• LOW CONDENSER WATER RETURN TEMP: IF THE CONDENSER WATER
RETURN TEMPERATURE IS LESS THAN 75°F (ADJ.).
CONTROLS LEGEND
ANALOG INPUT POINT
DIGITAL INPUT POINT
ANALOG OUTPUT POINT
DIGITAL OUTPUT POINT
2 WAY CONTROL VALVE
3 WAY CONTROL VALVE
TEMPERATURE PORT
MOTOR
CURRENT TRANSDUCER PUMP
PUMP
FLOW METER
FREEZESTAT
DAMPER
STATUS SWITCH
AI1
DI1
A01
D01
S
S
T
M
CT
T
S
S
A01
PURGE FAN ENABLE/DISABLED05
DI7
DI8
DI9
CONDENSER STATUS
EVAPORATOR STATUS
PURGE FAN STATUS
DP
D17
DP
D18
D06
DI9
D05
VFD
CONTROLS CONTRACTOR SHALL
SUPPLY AND INSTALL NEW VFD
FOR EXISTING FAN
AI8
AI8CONDENSER WATER FLOW
VALVE IS ETR
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
M301
MEC
HA
NIC
AL
CO
NTR
OL
DIA
GR
AM
S
MAKE-UP AIR UNIT CONTROL DIAGRAM
NO SCALE
HEATING VALVE
MAKE-UP AIR UNIT
LOCAL DDC CONTROLLER
AN
ALO
G
DIG
IT
AL
D01
OUTPUTS
A01
DIG
IT
AL
DI1
DI2
AN
AL
OG
AI1
INPUTS
PREFILTER DIFFERENTIAL PRESSURE
DI3
AI2SUPPLY AIR TEMP
AI3SUPPLY AIR TEMP SETPOINT
OUTSIDE AIR DAMPER STATUS
FREEZESTAT
SUPPLY FAN STATUS
H L
OA SA
M
Starter
CT
TS
HWS
HWR
M
T
HW
N.C.
DX
D02
D03
D04
COOLING STAGE 1
COOLING STAGE 2
OUTSIDE AIR DAMPER
SUPPLY FAN START/STOP
A01
DI3
D04
D01
D02
DI1
AI2
AI1
DI2
D03
1. MAKEUP AIR UNIT - SUPPLY AIR TEMP (TYPICAL OF 1)
RUN CONDITIONS - CONTINUOUS:
THE UNIT SHALL RUN CONTINUOUSLY.
FREEZE PROTECTION:
THE UNIT SHALL SHUT DOWN AND GENERATE AN ALARM UPON RECEIVING A
FREEZESTAT STATUS.
OUTSIDE AIR DAMPER:
THE OUTSIDE AIR DAMPER SHALL OPEN ANYTIME THE UNIT RUNS AND SHALL
CLOSE ANYTIME THE UNIT STOPS. THE SUPPLY FAN SHALL START ONLY AFTER
THE DAMPER STATUS HAS PROVEN THE DAMPER IS OPEN. THE OUTSIDE AIR
DAMPER SHALL CLOSE 4SEC (ADJ.) AFTER THE SUPPLY FAN STOPS.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• OUTSIDE AIR DAMPER FAILURE: COMMANDED OPEN, BUT THE STATUS IS
CLOSED.
• OUTSIDE AIR DAMPER IN HAND: COMMANDED CLOSED, BUT THE STATUS
IS OPEN.
SUPPLY FAN:
THE SUPPLY FAN SHALL RUN ANYTIME THE UNIT IS COMMANDED TO RUN. TO
PREVENT SHORT CYCLING, THE SUPPLY FAN SHALL HAVE A USER DEFINABLE
(ADJ.) MINIMUM RUNTIME, UNLESS SHUTDOWN ON SAFETIES.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• SUPPLY FAN FAILURE: COMMANDED ON, BUT THE STATUS IS OFF.
• SUPPLY FAN IN HAND: COMMANDED OFF, BUT THE STATUS IS ON.
• SUPPLY FAN RUNTIME EXCEEDED: STATUS RUNTIME EXCEEDS A USER
DEFINABLE LIMIT (ADJ.).
SUPPLY AIR TEMPERATURE SETPOINT - FIXED:
THE CONTROLLER SHALL MONITOR THE SUPPLY AIR TEMPERATURE AND SHALL
MAINTAIN A FIXED SUPPLY AIR TEMPERATURE SETPOINT OF 55°F (ADJ.).
COOLING STAGES:
THE CONTROLLER SHALL MEASURE THE SUPPLY AIR TEMPERATURE AND STAGE
THE COOLING TO MAINTAIN ITS COOLING SETPOINT. TO PREVENT SHORT
CYCLING, THERE SHALL BE A USER DEFINABLE (ADJ.) DELAY BETWEEN STAGES,
AND EACH STAGE SHALL HAVE A USER DEFINABLE (ADJ.) MINIMUM RUNTIME.
THE COOLING SHALL BE ENABLED WHENEVER:
• OUTSIDE AIR TEMPERATURE IS GREATER THAN 60°F (ADJ.).
• AND THE SUPPLY AIR TEMPERATURE IS ABOVE COOLING SETPOINT.
• AND THE FAN STATUS IS ON.
HEATING COIL VALVE:
THE CONTROLLER SHALL MEASURE THE SUPPLY AIR TEMPERATURE AND
MODULATE THE HEATING COIL VALVE TO MAINTAIN ITS HEATING SETPOINT.
THE HEATING SHALL BE ENABLED WHENEVER:
• OUTSIDE AIR TEMPERATURE IS LESS THAN 65°F (ADJ.).
• AND THE SUPPLY AIR TEMPERATURE IS BELOW HEATING SETPOINT.
• AND THE FAN STATUS IS ON.
THE HEATING COIL VALVE SHALL OPEN TO 100% (ADJ.) WHENEVER THE
FREEZESTAT IS ON.
PREFILTER DIFFERENTIAL PRESSURE MONITOR:
THE CONTROLLER SHALL MONITOR THE DIFFERENTIAL PRESSURE ACROSS THE
PREFILTER.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• PREFILTER CHANGE REQUIRED: PREFILTER DIFFERENTIAL PRESSURE
EXCEEDS A USER DEFINABLE LIMIT (ADJ.).
SUPPLY AIR TEMPERATURE:
THE CONTROLLER SHALL MONITOR THE SUPPLY AIR TEMPERATURE.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
• HIGH SUPPLY AIR TEMP: IF THE SUPPLY AIR TEMPERATURE IS GREATER
THAN 120°F (ADJ.).
• LOW SUPPLY AIR TEMP: IF THE SUPPLY AIR TEMPERATURE IS LESS
THAN 45°F (ADJ.).
DAMPER AND SMOKE
DETECTOR ARE ETR -
PROVIDE NEW
CONTROL POINTS
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
M302
MEC
HA
NIC
AL
CO
NTR
OL
DIA
GR
AM
S
POWER SYSTEM LEGEND
LIGHT AND SOLID INDICATES EXISTING TO REMAIN
HEAVY AND DASHED INDICATES EXISTING TO BE
DEMOLISHED.
HEAVY AND SOLID INDICATED NEW TO BE PROVIDED.
LINE TYPE LEGEND
1. UNLESS SPECIFICALLY NOTED TO BE EXISTING, ALL WORK AND MATERIAL
SHOWN IS NEW AND SHALL BE PROVIDED BY THE CONTRACTOR. WHEREVER A
"NEW TO EXISTING" ELECTRICAL CONNECTION IS REQUIRED, PROVIDE ALL
ACCESSORIES, SPLICES, CONDUIT, FITTINGS, AND MISCELLANEOUS
HARDWARE AND COMPONENTS AS NECESSARY TO EFFECT THE
CONNECTIONS. PROVIDE ALL DRILLING, CUTTING AND PATCHING OF THE
EXISTING BUILDING STRUCTURE AS NECESSARY TO PROPERLY INSTALL
ELECTRICAL CONDUITS AND ALL MATERIALS PROVIDED UNDER THE
CONTRACT.
2. THE CONSTRUCTION CONTRACT DRAWINGS ARE BASED UPON AS-BUILT
DRAWINGS AND VISUAL FIELD OBSERVATIONS AND WITHOUT DE-ENERGIZING
ANY ELECTRICAL CIRCUITS AS REQUIRED TO OBTAIN DETAILED INFORMATION.
THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE EXISTING
CONDITIONS IN ORDER TO AVOID CONFLICTS AND TO VERIFY THE ACTUAL
EXISTING CONDITIONS OF ALL AFFECTED CIRCUITRY AND EQUIPMENT. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE ACTUAL SIZES
AND TYPES OF EXISTING CONDUCTORS AND CONDUITS THAT ARE BEING
EXTENDED AS PART OF THE CONTRACT.
3. ALL WORK IN THE BUILDING SHALL BE SCHEDULED AT TIMES THAT ARE
CONVENIENT AND ACCEPTABLE TO THE OWNER. ENTIRE FACILITY SHALL
REMAIN OPERATIONAL DURING THE ENTIRE CONSTRUCTION PERIOD. ALL
REQUIRED POWER OUTAGES SHALL BE PLANNED AHEAD OF TIME SO THAT
THE DURATION OF EACH OUTAGE IS MINIMIZED. PROVIDE ALL NEW
CONSTRUCTION TO THE FULLEST EXTENT POSSIBLE PRIOR TO ANY GIVEN
OUTAGE. WHERE A UTILITY COMPANY IS REQUIRED TO SHUTDOWN OR
DE-ENERGIZE THEIR SYSTEM, THE CONTRACTOR SHALL BE RESPONSIBLE FOR
CONTACTING THE RESPECTIVE UTILITY COMPANY AND COORDINATING ALL
ASSOCIATED EFFORTS. PROVIDE WRITTEN NOTICE TO THE OWNER OF ANY
PLANNED POWER OUTAGE. NOTICE SHALL BE GIVEN TO THE OWNER A
MINIMUM OF FOURTEEN DAYS PRIOR TO PLANNED OUTAGE. NO OUTAGE
SHALL BE ALLOWED UNLESS SPECIFICALLY APPROVED IN WRITING BY THE
OWNER.
4. NEW CONDUIT PENETRATIONS THROUGH BLOCK, BRICK AND/OR CONCRETE
WALLS, FLOORS AND OTHER SIMILAR CONSTRUCTION SHALL BE
ACCOMPLISHED BY DRILLING THE ASSOCIATED STRUCTURES. HOLES LARGER
THAN ONE INCH SHALL BE CORE DRILLED. SEAL AND CAULK AROUND ALL
CONDUIT PENETRATIONS. PROVIDE PROPERLY RATED FIRE SEALS FOR ALL
CONDUITS THAT PENETRATE FIRE RATED CONSTRUCTION. EXTERIOR WALL
PENETRATIONS SHALL BE WATERPROOF.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING AND PATCHING OF
ALL INTERIOR AND EXTERIOR SURFACES REQUIRED FOR PROPER
INSTALLATION. ALL FINISHES SHALL BE REPAIRED AND PAINTED TO MATCH
EXISTING SURROUNDING FINISHES.
GENERAL ELECTRICAL NOTES
ABBREVIATIONS
PHASE
AMPERES
ABOVE FINISHED FLOOR
BREAKER
CONDUIT
CIRCUIT
GROUND
KILO-AMPS INTERRUPTING CAPACITY
THOUSANDS CIRCULAR MILS
SWITCHBOARD
Ø
A
AFF
BKR
C
CKT
GND
KAIC
KCMIL
SWBD
1. IT SHALL BE THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROTECT
AND RETAIN POWER TO ALL EXISTING ACTIVE EQUIPMENT WHICH SHALL
REMAIN.
2. DISCONNECT, REMOVE OR RELOCATE ALL ELECTRICAL MATERIAL AND
EQUIPMENT THAT INTERFERES WITH NEW INSTALLATION. THIS INCLUDES, BUT
IS NOT LIMITED TO CONDUITS, PANELS, LIGHTING FIXTURES, WIRING DEVICES,
SIGNAL EQUIPMENT, EXHAUST FANS, BASEBOARD HEATERS, UNIT HEATERS,
ETC. REMOVE ALL CONDUIT AND WIRING OF INACTIVE CIRCUITS COMPLETE
BACK TO THEIR ORIGIN AT THE ASSOCIATED PANELBOARD UNLESS OTHERWISE
NOTED.
3. REMOVE ALL CONDUIT, WIRE, BOXES AND FASTENING DEVICES AS REQUIRED
TO AVOID ANY INTERFERENCE WITH NEW INSTALLATION. CONDUITS MAY BE
ABANDONED IN FLOOR AND WALLS ONLY. ELECTRICAL CONTRACTOR SHALL
REMOVE ALL WIRING FROM ABANDONED CONDUITS, DISCONNECT FROM ALL
POWER SOURCES AND PROVIDE STAINLESS STEEL BLANK PLATES ON ALL
ABANDONED OUTLETS. CUT OFF ABANDONED CONDUITS 1" BELOW FINISHED
FLOOR AND GROUT FLUSH. ABANDONED CONDUIT SHALL BE CAPPED AT BOTH
ENDS.
4. ELECTRICAL CONTRACTOR SHALL RECONNECT ANY EQUIPMENT BEING
DISTURBED BY THE RENOVATION YET REQUIRED FOR CONTINUED SERVICE TO
SAME PANEL.
5. ELECTRICAL CONTRACTOR SHALL RING OUT ALL CIRCUITS IN EXISTING PANELS
AFFECTED BY THIS ALTERATION. NEW, TYPED PANELBOARD SCHEDULES SHALL
BE PROVIDED FOR ALL PANELS AFFECTED BY THIS ALTERATION.
6. REMOVE ALL EXISTING DEVICES AS INDICATED AND/OR REQUIRED TO CLEAR
AREA FOR NEW INSTALLATION.
7. COORDINATE WORK SCHEDULE IN EXISTING BUILDING WITH OWNER'S
REPRESENTATIVE.
8. ANY ELECTRICAL OUTAGES REQUIRED BY THE WORK SHALL BE COORDINATED
WITH OWNER'S REPRESENTATIVE AND CONFIRMED IN WRITING. ANY OUTAGE
SHALL NOT BE SCHEDULED DURING NORMAL BUSINESS HOURS AND ALL COSTS
FOR OVERTIME SHALL BE INCLUDED IN THE BID.
9. ANY DAMAGE DONE TO THE EXISTING BUILDING BY THE CONTRACTOR SHALL BE
REPAIRED BY THE CONTRACTOR TO THE SATISFACTION OF THE OWNER AT NO
ADDITIONAL CHARGE.
10. ALL BREAKERS AND THEIR ASSOCIATED HARDWARE NOT BEING REUSED SHALL
BE CAREFULLY REMOVED AND TURNED OVER TO THE OWNER IN THE SAME
CONDITION IN WHICH IT WAS FOUND, OR LABELED AS 'SPARE' WHERE
REMAINING INSTALLED IN THE EXISTING PANELBOARD.
GENERAL DEMOLITION NOTES
PANELBOARD, 208Y/120 VOLT, 3 PHASE, 4 WIRE, SOLID
NEUTRAL.
BRANCH CIRCUITS CONDUCTORS IN CONDUIT, RUN
CONCEALED IN WALLS UNDERGROUND AND ABOVE CEILING
EXCEPT IN EXPOSED CONSTRUCTION AREAS. REFER TO
PANELBOARD SCHEDULES FOR CONDUCTOR SIZES.
PROVIDE A GROUND WIRE IN ALL CIRCUITS.
HOMERUN TO PANELBOARD, PANELBOARD AND CIRCUIT
DESIGNATION AS INDICATED.
EQUIPMENT CONNECTION.
JUNCTION BOX WITH BLANK COVERPLATE.
DISCONNECT SWITCH, 240 OR 600 VOLTS AS REQUIRED,
AMPS AND POLES, FUSING AS NOTED. 3P = NUMBER OF
POLES, 60 = SWITCH AMPERE RATING, 40 = FUSE AMPERE
RATING (NF = NON-FUSED), 3R = ENCLOSURE NEMA RATING
IF OTHER THAN NEMA 1.
MOTOR STARTER WITH SOLID STATE OVERLOAD RELAYS.
E
MEQ-17
60
40
3P 3R
J J
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
E001
ELEC
TRIC
AL
LEG
END
S, N
OTE
S A
ND
SC
HED
ULE
S
DISCONNECT EXISTING CHILLER. REMOVE CIRCUITING AS INDICATED.
REMOVE EXISTING FUSES IN DISCONNECT SWITCH.
REMOVE EXISTING DISCONNECT SWITCH. CIRCUITING SHALL REMAIN FOR
CONNECTION OF NEW DISCONNECT SWITCH IN EXISTING LOCATION. REMOVE FUSES
FROM DISCONNECT SWITCH AND STORE FOR INSTALLATION IN NEW DISCONNECT
SWITCH.
DISCONNECT EXISTING REFRIGERANT MONITORING SYSTEM. CIRCUITING SHALL
REMAIN FOR CONNECTION OF NEW REFRIGERANT MONITORING SYSTEM IN EXISTING
LOCATION.
DISCONNECT EXISTING PUMP, PA-12. CIRCUITING SHALL REMAIN FOR CONNECTION
OF PUMP AT NEW LOCATION.
1
DEMOLITION NOTES THIS SHEET
1
2
HUNTER SQUARE MECHANICAL ROOM - ELECTRICAL DEMOLITION PLAN
SCALE: 1/4" = 1'-0"
EXISTING GATE (ACCESS
FOR CHILLER REMOVAL)
EXISTING ROLL-UPDOOR
3
3
E
J
EXISTING MAIN SWITCHBOARD
1/4" = 1'-0"
5' 0 5' 10'
3
2
GRAPHIC SCALE
AREA OF WORK
KEYPLAN
NO SCALE
PA-12
4
E
4
5
5
60
*
3P
60
*
3P
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
ED101
HU
NTE
R S
QU
AR
E EL
ECTR
ICA
L D
EMO
LITI
ON
PLA
N
NOTES THIS SHEET
DISCONNECT EXISTING DEDICATED OUTSIDE AIR UNIT. REMOVE EXISTING STARTER AND DISCONNECT
SWITCH. REMOVE CIRCUITING BACK TO PANEL.
DISCONNECT EXISTING CONDENSING UNIT. REMOVE EXISTING DISCONNECT SWITCH. REMOVE
CIRCUITING BACK TO PANEL.
BOBBITT FIRST FLOOR ELECTRICAL PLAN
SCALE: 1/4" = 1'-0"
MUA-1
ED102 ED102
E
MEQ-17
MAIN SWITCHBOARD SWBD
PANEL MEQ
PANEL MEQ2
1" = 10'-0"
10' 5' 0 10' 20' 30'
1/4" = 1'-0"
5' 0 5' 10'
1
2
1
GRAPHIC SCALE
30
**
3P
BOBBITT SITE ELECTRICAL PLAN
SCALE: 1" = 10'-0"
E
2
MSB-2
200
**
3P 3R
ED102 ED102
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
ED102
BO
BB
IT E
LEC
TRIC
AL
DEM
OLI
TIO
N P
LAN
S
COOLING TOWER, ETR
EXISTING GATE (ACCESS
FOR CHILLER REMOVAL)
EXISTING ROLL-UPDOOR
E
J
EXISTING MAIN SWITCHBOARD
30
**
3P 3R
60
**
3P 3R
HUNTER SQUARE MECHANICAL ROOM - ELECTRICAL NEW WORK PLAN
SCALE: 1/4" = 1'-0"
CONNECT NEW CHILLER AT EXISTING LOCATION WITH FOUR 350 KCMIL AND ONE #4
GROUND IN 3" CONDUIT.
PROVIDE NEW 300 AMP FUSES IN EXISTING DISCONNECT SWITCH. EXISTING
DISCONNECT SWITCH IS A SIEMENS I-T-E ENCLOSED HEAVY DUTY DISCONNECT
SWITCH CAT NO F355 SERIES B.
NEW DISCONNECT SWITCH AT EXISTING LOCATION. EXTEND AND REWORK
CIRCUITING AS NECESSARY. INSTALL EXISTING FUSES SAVED DURING DEMOLITION.
CONNECT NEW REFRIGERANT MONITORING SYSTEM AT EXISTING LOCATION.
EXTEND AND REWORK WIRING AS NECESSARY.
CONNECT EXISTING PUMP AT RELOCATED LOCATION. EXTEND AND REWORK
CIRCUITING AS NECESSARY.
DEMOLITION NOTES THIS SHEET
1/4" = 1'-0"
5' 0 5' 10'
1
2
3
3
1
3
2
GRAPHIC SCALE
AREA OF WORK
KEYPLAN
NO SCALE
E
4
5
4
5J
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
E101
HU
NTE
R S
QU
AR
E EL
ECTR
ICA
L N
EW W
OR
K P
LAN
NOTES THIS SHEET
CONNECT NEW MAKE UP AIR UNIT. EXTEND AND REWORK CIRCUITING AS NECESSARY.
CONNECT NEW CONDENSING UNIT. EXTEND AND REWORK CIRCUITING AS NECESSARY.
SCALE: 1/4" = 1'-0"
E
SWBD-16
MAIN SWITCHBOARD
PANEL MEQ
PANEL MEQ2
1" = 10'-0"
10' 5' 0 10' 20' 30'
1/4" = 1'-0"
5' 0 5' 10'
1
2
MUA-1
1
100
NF
3P 3R
GRAPHIC SCALE
BOBBITT ELECTRICAL NEW WORK PLAN
ED102 ED102
SCALE: 1" = 10'-0"
E
MEQ-17
60
35
3P 3R
2
BOBBITT SITE ELECTRICAL PLAN
ED102 ED102
BO
BB
ITT
MA
KE-
UP
AIR
AN
D
NO
RFO
LK, V
IRG
INIA
HU
NTE
R S
QU
AR
E C
HIL
LER
REP
LAC
EMEN
T91
0 B
ALL
LEN
TIN
E B
LVD
NO
RFO
LK, V
IRG
INIA
E102
BO
BB
IT E
LEC
TRIC
AL
NEW
WO
RK
PLA
NS