19
ARIDES(Advanced Real-time Information DEployment Solution)
DCS HMI Solution for safe and effective operation of power plants
HMI solution for Nuclear Industry•More than 30 years experiences specialized in Nuclear Power Plants•Monitoring and control for nuclear power plants
HMI solution for Coal-fired and Gas-fired power plants•Monitoring and control for Coal-fired Power Plants•Monitoring and control for Combined-Cycle, Combined Heat andPower Plants
Upgrading legacy DCS HMI•Solving the problem caused by legacy DCS HMI and low performancehistorian
•Upgrading GE Mark V - 16 Systems•Upgrading GE EX2000 - 30 Systems•Upgrading SIEMENS SPPA-T2000 or TXP - 2 Systems•Upgrading ABB Procontrol P13, P42 - 7 Systems•Upgrading MHI MIDAS 8000 - 1 System
DCS HMI Solution - ARIDES
2
Project Overview
Project Title
- On-Line Monitoring and Early Warning System for 24 Nuclear Power Units
Project Scope
- Build up the central monitoring center in the headquarter and research institute
- Real-time data acquisition for 24 nuclear units
- Centralize data from different sources into a single place
- Build up the predictive early warning system for 24 nuclear units
Project Duration
- Dec.26th, 2014 ~ May. 30th, 2016
<On-line Monitoring Center in the research center and headquarter>
3
This is what our client expected to see
Effective Resource Management
Reducing operation &
maintenance cost
Improving operation environment
and business process
• By monitoring and analyzing a
whole power units in the
headquarter, managing and
planning resources timely and
effective • By reinforcing accuracy of
predictive diagnosis and analysis
with the specialized members, and
doing proper actions in advance,
reduce operation & maintenance
cost
• Improving operating environment
and business process by 24X7
specialized monitoring in a single
place
• Planning and managing optimized
processes by minimizing
information gaps between all
people of the headquarter and
plant sites
• Making a right decision in a timely
manner
Benefits
Client’s Expectations
4
Our project scope was to- Collect and archive real-time data from 24 nuclear units by the PRISM system
(Data from DCS, Vibration Monitoring System, - Centralize the data in a single place - Provide various applications to monitor and analyze the field data- Deploy the cyber security solution for enhanced network security
Unit 1
Unit 2
Unit 3
Unit 4
Unit 24
The Research Center The Headquarter
…
….
PRISM Client Suit- Pre-Engineered Functions : Easy to Use- Process Mimics- Various types of analytic tools - Various types of reports- Excel Add-in program- Script Engine
Gateway and PRISM Server- Data Scanning time is as same as data acquisition
system or OPC server- Archive max 500,000 points data in a single server
without any data loss- Quick to retrieve years of historical data within few
minutes
The Project Scope
5
We successfully deployed and are currently maintaining
- The predictive early warning solution at 24 nuclear power units
Unit 1
Unit 2
Unit 3
Unit 4
Unit 24
The Research Center The Headquarter
…
….
What PHI Identify in advance- Sensor Failure- Transmitter Failure- Communication Failure- Potential Equipment Failure-Improper process operation
PHI system- Automatically modeling operation patterns of each critical equipment by the most optimized plant condition in the past
- Early warning for potential failures- Monitoring plant conditions with index- Various analytic tools to analyze causes of problem
Power Plant Predictive Analytics