Solutions for Building Management

HVAC

Page 2: BME UB HVAC 99 1115 - Badger Meter Europa...For Slovakia & Czech Republic BME__HVAC_ UB_02_1901 Due to continuous research, product improvements and enhancements, Badger Meter reserves

Measurable performanceYou and your customers expect peak performance every day year-round from your HVAC, hydronic chilled and hot water applications. Optimizing these systems to meet ever changing requirements and tenant demands can be time consuming and costly.Our products provide reliable accurate measurements, energy calculations and integrated data communications of products that provide energy and flow measurement designed to obtain the highest system performance possible even under the most challenging conditions.

Building Management Solutions

HVAC SystemsMeasure your energy costs for both hydronic chilled and hot water applications with impeller and Dynasonics® Btu meters from Badger Meter. Both systems integrate metering components with flow and temperature sensors to provide an effective metering solution for your facility.

Our systems have the flexibility to interface with most control systems utilizing BACnet™ MSTP, BACnet/IP, EtherNet/IP, LonWorks®, Metasys®, ModBus® RTU or ModBus® TCP/IP. Scaled pulse and analog outputs are also available.

Badger Meter offers solutions for:• Energy metering and submetering• Irrigation management• Water and waste water management• Data acquisition and analysis

Applications:• Energy metering and submetering• Energy distribution• System monitoring• Operating efficiency calculations

01

Page 3: BME UB HVAC 99 1115 - Badger Meter Europa...For Slovakia & Czech Republic BME__HVAC_ UB_02_1901 Due to continuous research, product improvements and enhancements, Badger Meter reserves

Product Solutions

02

Ultrasonic energy meter DXN and TFX Ultra®

The ultrasonic energy meters DXN and TFX Ultra® can be clamped-on outside of the pipe and do not come into contact with the liquid. The energy meter measures flow and also energy usage in BTU, MBTU, MMBTU, tons, kJ, kW, kWh, MW and is ideal for retrofit liquid and HVAC applications.

• Ultrasonic technology• DN 50 – DN 3000• Accuracy of ±1 % of reading• -40 °C up to +85 °C/120 °C

Impeller model Btu 380 is used for simple in-line operations. Type Btu 380 provides BACnet® MSTP and ModBus® RTU protocols as standard. The chosen protocol can be user defined. Data about flow rates, total range, energy, total flow, temperature 1, temperature 2 and ∆t can be transmitted with the RS 485.

• Impeller technology• DN 20 – DN 50• Accuracy of ±3 % of full scale• 20 °C up to +60 °C

Electromagnetic flow meter ModMAG® M1000 / ModMAG® M2000The electromagnetic flow meters ModMAG® M1000 and ModMAG® M2000 display all necessary information such as flow rate, total flow rates, daily flow rate or even an alert. The information can be read-out from an LCD display. Both models offer various inputs, outputs and interfaces and can ideally be used with the heat calculator 212 in cooling or heating system measurements.

• Electromagnetic flow measurement• DN 6 – 2000• Accuracy of ±0,2 % or 0,3 % of actual value (acc. to model)• -40 °C up to +150 °C

212 Energy calculatorThe 212 energy calculator has been designed to measure the energy consumed in hot water heating systems and chilled water cooling systems. The 212 is supplied with temperature probes and easily interfaces with our MAG meters, impeller meters and non-invasive ultrasonic meters.

• Complies with OIML R75 and EN1434 standards• Provides multilingual capability• For hot water heating systems and chilled water cooling

systems• M-Bus, ModBus® RTU RS 485• IP 66 (Nema 4x)• CE compliant

UHC100 ultrasonic heat meter /cooling energy meterThe UHC100 has been designed to measure heating and cooling energy. It can be used with heating media (water or glyco solution) in centrally heated objects like residential houses or heat supply.

• Ultrasonic technology• High accuracy• MID DN15 – DN100• 0 °C up to +90 °C or 0 °C up to +130 °C

Page 4: BME UB HVAC 99 1115 - Badger Meter Europa...For Slovakia & Czech Republic BME__HVAC_ UB_02_1901 Due to continuous research, product improvements and enhancements, Badger Meter reserves

DXN ModMAG®

M1000

Flow meter

Water return

Water delivery

10D 5D

TFX Ultra®

212 Energy calculator

Temperature sensor on return line

Temperature sensor on supply line

UHC100 DFX ModMAG® M2000

BME_

_HVA

C_ U

B_02

_190

1 D

ue to

con

tinuo

us re

sear

ch, p

rodu

ct im

prov

emen

ts a

nd e

nhan

cem

ents

, Bad

ger

Met

er re

serv

es th

e rig

ht to

cha

nge

prod

ucts

spec

ifica

tions

with

out p

rior n

otice

.

For Slovakia & Czech RepublicBadger Meter Slovakia s. r. o.Racianska 109 / B83102 BratislavaSlovakiaTel. +421-2-44 63 83 01Fax +421-2-44 63 83 [email protected]

For the USA, Canada and Latin AmericaBadger Meter, Inc.P.O. Box 245036Milwaukee, WI 53224-9536USATel. +1-414-355-04 00Fax +1-414-355-74 [email protected]

For MexicoBadger Meter de las Americas S. A. de C. V.Pedro Luis Ogazon #32Col. Guadalupe InnMexico, D. F. 01020MexicoTel. +52-55-56 62-08 82Fax +52-55-56 62-75 [email protected]

For SwitzerlandBadger Meter Swiss AGMittelholzerstr. 83006 BernSwitzerlandTel. +41-31-93 20 111Fax +41-31-93 10 [email protected]

For the Middle EastBadger Meter EuropeMiddle East Branch OfficeDubai Silicon OasisHead Quarter BuildingWing C, Office #C209Dubai / UAETel. +971-4-371 2503Fax +971-4-371 [email protected]

For AsiaBadger Meter Europa GmbHSingapore Branch80 Marine Parade Road#19–07 Parkway ParadeSingapore 449269SingaporeTel. +65-63 46 48 36Fax +65-63 46 48 [email protected]

For Poland, Ukraine, Belarus and the Baltic countriesBadger Meter Eastern Europe Eastern Europe Branch Officeul. Korfantego 644-193 Knurów / PolandTel. +48-32 236 744 [email protected]

Badger Meter Europa GmbHNürtinger Str. 7672639 NeuffenGermanyTel. +49-70 25-92 08-0Fax +49-70 25-92 [email protected]