AgendaAgenda Transition to the 3051SMV: 3095M-HART Discontinuance

– 3095M-HART Final Order Date– Models Affected

3051SMV Feature Improvements– 3095M-HART Comparison– Flowmeter Offering– Engineering Assistant Support

Summary

Page 3: Blue Horizon Emerson Confidential 3051SMV Transition

3Blue HorizonEmerson Confidential

Since the release of the 3051SMV in Oct. 2009, market led transition was expected– 3051SMV has higher performance and more features

Transition time-frame shortened by Japanese crisis– Earthquake and resulting tsunami destroyed a supplier’s factory– Supplier has decided to discontinue the component– Timeframe to redesign unacceptable– No other 3095 or Rosemount products are affected

Transition to the 3051SMV from the 3095M-HARTTransition to the 3051SMV from the 3095M-HART

40% of customers already transitioned

Page 4: Blue Horizon Emerson Confidential 3051SMV Transition

4Blue HorizonEmerson Confidential

3095M-HART Final Order Date3095M-HART Final Order Date Final Order Date:

July 29, 2011

Orders will ship at standard lead-times Service and warranty requests will be honored with

remaining 3095M-HART inventory or an upgrade to 3051SMV– Option to upgrade at the cost to repair a 3095M through for two

years or five years from the original shipment date of device, whichever comes first

Page 5: Blue Horizon Emerson Confidential 3051SMV Transition

5Blue HorizonEmerson Confidential

3095M-HART Models To Be Transitioned3095M-HART Models To Be Transitioned 3095MA HART Transmitters

– 3095MAxxxxxxxxxxxxx…– NOT Affected:

• 3095MV FOUNDATION fieldbus • 3095FB MODBUS

3095MFx HART Flowmeters– 3095MFAxxxxxxxxxxxxxxxxxAxx...– 3095MFCxxxxxxxxxxxxxAxx…– 3095MFPxxxxxxxxxxxxxxxAxx…– NOT Affected:

• 3095MFx FOUNDATION fieldbus Flowmeters

3095MFP 3095MFA 3095MFC

3095MA HART

Page 6: Blue Horizon Emerson Confidential 3051SMV Transition

6Blue HorizonEmerson Confidential

Sensor Matching with Callendar-van Dusen

RTD with Sensor Matching

Standard RTD Sensor

RTD Sensor Accuracy2 ºC (3.6 ºF)

-2 ºC (-3.6 ºF)

1 ºC (1.8 ºF)

-1 ºC (-1.8 ºF)

0 ºC (0 ºF)

400 ºC (752 ºF)0 ºC (32 ºF) 200 ºC (392 ºF )

User specified temperature limits and temperature backup

Time

Te

mp

era

ture

User-specified

User-specified

Fixed (Hard Limit)

Fixed (Hard Limit)

Early Detection

Backup temperature or alarm enabled

Temperature sensor limit

Terminal block temperature wiring

Energy and Mass or Actual Volumetric Flow

DPEdYNCQ Dmass2

1

DP

TP

DPP PT TT T

Coefficients vary with all three

measurements

Accurate Flow Measurement Requires Dynamic Compensation

DP

Real-time compensation of over 25 variables @ 22 updates/second

Pcan

Patmosphere

Tspray

Because Pcan > Patmosphere

Then Tcan ≠ Tspray

Tcan

COLD

Joule Thomson Correction

Gas, Natural Gas and All Steam

Saturated Steam

1. Differential Pressure2. Pressure3. Temperature

1. Differential Pressure2. Pressure

1. Differential Pressure2. Temperature

1. Differential Pressure

o

o

o

o

oo

o

o

Liquids and Saturated Steam

Liquids

Scalable Compensation

Ultra For Flow

Flow Turndown

% Reading

0123456789

10

10:1 5:1 3:1 2:1 1:1

3051S UltraUltra for Flow

±0.1% Span3051C

Rosemount 3051S MultiVariable HART Transmitter

Easy 2 StepConfiguration

Page 7: Blue Horizon Emerson Confidential 3051SMV Transition

7Blue HorizonEmerson Confidential

Integrated Flowmeters Available With the 3051SMVIntegrated Flowmeters Available With the 3051SMV

3051SFx Flowmeters Offer Equivalent 3095MFx Features– Fully Assembled, Configure, Leak Tested– Annubar, Compact Orifice, and Integral Orifice– Integral Temperature option

3051SFP3051SFA 3051SFC

Page 8: Blue Horizon Emerson Confidential 3051SMV Transition

8Blue HorizonEmerson Confidential

Transitioning to the Rosemount 3051SMV Improves Flow Measurement Transitioning to the Rosemount 3051SMV Improves Flow Measurement

Rosemount 3051SMV

Rosemount 3095M-HART

Mass or Energy Flow Reference Accuracy

Ultra for Flow: ±0.65% Rate over 14:1

Classic MV: ±0.70% Rate over 8:1

U3: ±1.0% of Rate over 10:1

Std.: ±1.0% of Rate over 8:1

Totalized Mass Flow Accuracy

±0.65% of Total Mass or Energy Flow

±1.0% of Total Mass Flow

Rangeability DP: 200:1AP: 200:1

DP: 100:1AP: 100:1

WarrantyUltra and Ultra for Flow:

12 yearsClassic: 12-18 months

U3: 12 yearsStandard: 12-18

months

Update Rate 22 updates / second 2.5 updates / second

Energy flow Calculation

Natural gas and Steam Not Available

Scalable Measurement Solutions

All combinations of DP, P, T

DP+P+T orDP+P (Fixed T)

3051SMV: Superior Flow Measurement

• Improved Mass and Energy Flow

Calculations

• Scalable Measurement Options for Liquids

and Saturated Steam

• Easy Start-up and Simplified Maintenance

with Engineering Assistant 6.1.1

Page 9: Blue Horizon Emerson Confidential 3051SMV Transition

9Blue HorizonEmerson Confidential

3095M-HART

Coplanar Connection

Height: 7.07-in. (180 mm)

Weight: 6.0 lbs (2.7 kg)

Temperature Connection– Temperature Boss

3051SMV vs. 3095M-HARTPhysical Comparison3051SMV vs. 3095M-HARTPhysical Comparison

3051SMV

Coplanar Connection

Height: 8.53-in. (217 mm)– 1.46-in. (37 mm) taller

Weight: 6.7 lbs (3.0 kg)– 0.7lb (0.3 kg) heavier

Temperature Connection– Terminal Block

Page 10: Blue Horizon Emerson Confidential 3051SMV Transition

10Blue HorizonEmerson Confidential

3051SMV vs. 3095M-HARTDimensional Comparison3051SMV vs. 3095M-HARTDimensional Comparison

Measurement 3051SMV 3095MA

A Overall Height 8.53 (217) 7.07 (180)B Width of Transmitter, without

LCD Display4.55 (116) 4.3 (110)

C Width of Transmitter, with LCD Display

5.21 (132) 5.00 (127)

D Process Connection Center-to-Center

2.1 (54) 2.1 (54)

3051SMV 3095M-HART

Page 11: Blue Horizon Emerson Confidential 3051SMV Transition

11Blue HorizonEmerson Confidential

Engineering Assistant SupportEngineering Assistant Support

EA 6.1.1 For 3051SMV Stand alone

AMS SNAP-ON planned Full listing of fluids Most primaries supported Ongoing maintenance

releases for new capabilities

EA 5.5.1 For 3095M Stand alone

powered by AMS AMS SNAP-ON Full listing of primary

elements and fluids Available to support

legacy installations

Both versions will continue to be available

Page 12: Blue Horizon Emerson Confidential 3051SMV Transition

12Blue HorizonEmerson Confidential

Start Your Transition to the 3051SMV Transmitter and Flowmeters TodayStart Your Transition to the 3051SMV Transmitter and Flowmeters Today REMEMBER: Last Order Date for 3095M-HART

– July 29, 2011

3051SMV Offers Equivalent 3095M-HART Features and More:– Superior Flow Measurement Performance– Improved Temperature Measurement– Fully Integrated Flowmeters

3051SFP

3051SFA

3051SFC

Page 13: Blue Horizon Emerson Confidential 3051SMV Transition