InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 1 BL67 – Table of Contents BL67 – Gateways DeviceNet 14 PROFIBUS ® -DP 16 BL67 – Electronic and Base Modules Power Feeder Module 18 Digital Input Modules 20 Digital Output Modules 24 Analog Input Modules 28 Resistive Thermal Device Input Module 30 Thermocouple Input Module 32 Analog Output Modules 34 Serial Interface Module 36 BL67 – Accessories I/Oassistant Software 38 BL67 – Labels 39 BL67 – Manuals 39 BL67 – Programming Cable 39 BL67 – System Concept 2 BL67 – Module Key 4 Quick Selection Guide 5 BL67 – General System Description – BL67 and PROFIBUS ® -DP 6 System Description – BL67 and DeviceNet 8 BL67 – Power Distribution 10 BL67 – Dimensions 12 BL67 – Environmental Conditions 13 2 3 1 5 Installations 105 Flexlife ® 10 Performance 106 Cable Bundling Techniques 107 Cable Installation 108 Cable and Accessories DeviceNet 41 Power Cordsets for DeviceNet 72 Power Field Wireables for DeviceNet 75 PROFIBUS ® -DP 77 Power Cordsets for PROFIBUS ® -DP 89 Power Field Wireables for PROFIBUS ® -DP 91 I/O Cordsets 93 Cable Characteristics 103 4 Index of Components 110 Warranty Statement 112

BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 1

BL67 – Table of Contents

BL67 – GatewaysDeviceNet™ 14PROFIBUS®-DP 16

BL67 – Electronic and Base ModulesPower Feeder Module 18Digital Input Modules 20Digital Output Modules 24Analog Input Modules 28Resistive Thermal Device Input Module 30Thermocouple Input Module 32Analog Output Modules 34Serial Interface Module 36

BL67 – AccessoriesI/Oassistant Software 38BL67 – Labels 39BL67 – Manuals 39BL67 – Programming Cable 39

BL67 – System Concept 2BL67 – Module Key 4Quick Selection Guide 5

BL67 – GeneralSystem Description – BL67 and PROFIBUS®-DP 6System Description – BL67 and DeviceNet™ 8BL67 – Power Distribution 10BL67 – Dimensions 12BL67 – Environmental Conditions 13

2

3

1

5 Installations 105

Flexlife®10 Performance 106Cable Bundling Techniques 107Cable Installation 108

Cable and AccessoriesDeviceNet™ 41Power Cordsets for DeviceNet™ 72Power Field Wireables for DeviceNet™ 75PROFIBUS®-DP 77Power Cordsets for PROFIBUS®-DP 89Power Field Wireables for PROFIBUS®-DP 91I/O Cordsets 93Cable Characteristics 103

4

Index of Components 110

Warranty Statement 112

Page 2: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-58802

The BL67 Concept

The BL67 modular concept is a very flexibleapproach to connectorized I/O; the gateway,base, and electronic module combine manybenefits. I/O modules are not dependent on thefieldbus protocol with the BL67 gateway. Thegateway provides communication between thefieldbus and the I/O modules. The DIN-rail, orframe mountable base modules, are availablewith eurofast®, minifast® and picofast® connec-tors. The electronic modules are hotswappable. The power distribution module (24VDC) supplies the connected I/O with therequired voltage. The system supports multiplenetworks and a wide variety of I/O signals in acompact and rugged housing. The BL67’sstrengths are its openness, flexibility,connectorization and ruggedness.

Gateway

• Interface between the BL67 station and the fieldbus

• Supports PROFIBUS®-DP and DeviceNet™

• Coordinates the entire I/O data exchange

• Generates detailed diagnostic information for the PLC

• Provides I/Oassistant configuration and monitoring software interface

• Provides rotary switches for setting network address

• The I/O modules are independent of the bus system

DeviceNet™

Address Window

The BL67 Solution

BL67 combines all the flexibility of in the cabinet PLC I/O systems, with modularity,ruggedness, and connectorization. BL67 is a complementary product to the AIM™,BL20, and piconet® product families to meet the needs of unique applications such assmall machine or conveyor systems requiring IP67 protection.

Gateway

Page 3: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 3

Connectorized Base Modules

• Available in eurofast®, minifast® or picofast® connectors

• Eliminates wiring errors

• Greatly reduces wiring time and cost

Electronic Modules

• Available in digital, analog, temperature, RS232/485 and more

• Communicate with the gateway via an internal bus

• Independent of the higher-level fieldbus

• Replaceable without removing I/O wiring

• Available with 2, 4 or 8 channels

• Color coded for easy identification

Software I/Oassistant

• Project planning

• Documentation

• Configuring BL67 Station

• Monitoring I/O data

• Error logging

Mechanical Key

• Keys an electronic module to a particular base module

• Prevents insertion of incorrect electronic module

Power Feeder Modules

• Supplies isolated 24VDC to electronic modules

• Create isolated groups of I/O

Base Module

Electronic ModuleLED’s

1

Page 4: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-58804

BL67 – Module Key

BL67 – Gateways

BL67 – Base Modules

B L 6 7 – 2 A I

Signal Number

Signal Type:AI = Analog InputAO = Analog OutputDI = Digital InputDO = Digital Outputetc.

– P

Additional Information:V = VoltageI = CurrentPT = Pt100, Pt1000, Ni100 etc.TC = ThermocoupleP = Paired

BL67 – Electronic Modules

B L 6 7 – B – 2 M 1 2

B Base Module

Connector Number:2/4/8

Connector Type:M8 = picofast®M12 = eurofast®

RSM = minifast®

– P

Wiring:P Paired8 8-pin

B L 6 7 – G W – DP

G W Gateway DP PROFIBUS®-DPDN DeviceNet™

Page 5: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 5

1

BL67 – Quick Selection Guide

BL67 – Electronic modules andcorresponding bases

BL6

7-B

-4M

8

BL6

7-B

-8M

8

BL6

7-B

-1R

SM

BL6

7-B

-1M

12

BL6

7-B

-1M

12-8

BL6

7-B

-2M

12

BL6

7-B

-2M

12-P

BL6

7-B

-4M

12

BL6

7-B

-4M

12-P

Bas

e M

od

ule

s

Pag

e

Digital Input Modules

BL67-4DI-P 20

BL67-8DI-P 22

Analog Input Modules

BL67-2AI-I 28

BL67-2AI-V 28

BL67-2AI-PT 30

BL67-2AI-TC 32

Digital Output Modules

BL67-4DO-0.5A-P 24

BL67-4DO-2A-P 24

BL67-8DO-0.5A-P 26

Analog Output Modules

BL67-2AO-I 34

BL67-2AO-V 34

Serial Interface Module

BL67-1RS232 36

Power Feeder Module

BL67-PF-24VDC 18

Page 6: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-58806

BL67 and PROFIBUS®-DP

System Description

PROFIBUS®, or “Process Field Bus”, is a standardized, open communication network. It complies with the DIN 19 245 standard andconsists of three different protocol profiles:

PROFIBUS®-FMS (Fieldbus Message Specification) is designed to handle the data exchange between PLC’s or PC-based controllers.InterlinkBT® stations are designed to support PROFIBUS®-DP, not FMS.PROFIBUS®-PA (Process Automation) is an intrinsically safe network for the process industry. InterlinkBT I/O stations do not supportPA.PROFIBUS®-DP (Decentralized Periphery) is designed to handle the data exchange between PLC’s and their I/O. InterlinkBT stationssupport PROFIBUS®-DP.PROFIBUS®-DP operates as a master slave system. It usually consists of a single Master (PLC) and from 4 to 30 or more slaves (I/OBlocks). When the system is running, the master simply polls each slave in sequence. It is possible to have multiple masters on anetwork. The masters then share the network by passing a token.PROFIBUS®-DP uses an industrially proven physical layer based on the RS-485 standard. It is a two-wire differential system that isextremely resistant to electrical interference. At 12 Mbps it’s the fastest in its class.PROFIBUS®-DP can accommodate a large number of I/O points. With up to 126 addressable nodes, systems may have thousandsof analog and digital I/O points per network.Every PROFIBUS®-DP device has a Device Master File (GSD File) associated with it. This file contains detailed information about thedevice, including: I/O data size, comm rates supported, revision, etc. To configure a station within a PROFIBUS®-DP system a GSD Filefor that station is required. GSD files are available at www.interlinkbt.com.InterlinkBT stations and cordsets are certified by the Profibus Trade Organization (PTO).

Maximum System Extension without Repeaters

A PROFIBUS®-DP bus line consists of at least a master anda slave. Without a repeater, a PROFIBUS®-DP bus line canconsist of up to 31 slaves.

Maximum System Extension with Repeaters

Repeaters can be used within a PROFIBUS®-DP structure.This increases the number of possible slaves to 122. Do notexceed the maximum number of 125 bus stations. ThePROFIBUS®-DP addresses 000, 126 and 127 are reservedand cannot be used for BL67.

A maximum of 32 devices can be connected on aPROFIBUS®-DP segment. A repeater allows 31 more devicesto be connected (32-1: the repeater itself is a device). Up to 4repeaters can be used on any network. In some cases,master timing characteristics may need to be adjusted.

Page 7: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 7

2

PROFIBUS®-DP

Maximum Size of the BL67 Station

A BL67 station consists of a gateway for PROFIBUS®-DP anda maximum of 32 modules (approximately 1 meter of din rail).

When using mixed systems (digital, analog, and serial modules together in one system), determining the number of modules thatare supported can become complicated. Maximum system size depends on a number of factors, such as : overall I/O data size,diagnostic data size, parameterization (or configuration) data size, and power requirements.

To determine exactly if a given system will work:1) Build the system using the I/Oassistant software2) Click on “Station” and then “Verify”The I/Oassistant will return “No Error” if the configuration is within total limits.

To quickly estimate if a system will work:Add up the fractional usage of each module. For example, consider a system with the following: 10 of the 8 DI modules 2 of the 1 RS232 modules 8 of the 2 AI-TC modules

- For the 8 DI we are using 10 out of 32 possible or 31.2 % of the total system resources- For the 1 RS232 we are using 2 out of 15 possible or 13.3% of the total system resources- For the 2 AI-TC modules we are using 8 out of 30 possible or 26.6% of the total system recources

Adding all the percentages together equals 71.1% which is less than 100%; this system will work.

Note: This simple aproach is a worst case approximation. Often you can build a system slightly larger than shown by this “esti-mate”. Use the I/Oassistant to determine the exact system limitations.

Maximum Station Extension,Based on Diagnostic Data Limits

Digital inputs, 8 DIDigital outputs, 8 DOAnalog inputs, 2 AIAnalog inputs, 2 AI-PTAnalog inputs, 2AI-TCAnalog outputs, 2 AO1RS232

Module TypeChannelMaximum

ModuleMaximum

2562566046603215

32323023301615

Maximum Station Extension,Based on I/O Data Limits

Digital inputs, 8 DIDigital outputs, 8 DOAnalog inputs, 2AIAnalog inputs, 2 AI-PTAnalog inputs, 2 AI-TCAnalog outputs, 2 AO1RS232

2562566446643215

32323223321615

Module TypeChannelMaximum

ModuleMaximum

Page 8: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-58808

BL67 and DeviceNet™

System Description

DeviceNet is a low-cost communications link to connect industrial devices such as limit switches, photoelectric sensors, valvemanifolds, motor starters, process sensors, bar code readers, variable frequency drives, panel displays and operator interfacesto a network and eliminate hard wiring. The direct connectivity provides improved communication between devices as well asimportant device-level diagnostics not easily accessible or available through hard-wired I/O interfaces.

DeviceNet is based on a broadcast-oriented communication architecture - the Controller Area Network (CAN). CAN uses theCSMA/BA bus arbitration method. CSMA/BA assures that the highest priority message always gets transmitted. TheDeviceNet protocol further defines message priorities such that I/O messages are given top priority and configuration mes-sages have lower priority.

A DeviceNet network supports up to 64 nodes and an unlimited amount of I/O. The bus uses a trunkline-dropline topology. Buspower and communication are supplied on a single cable. Bus power is 24 VDC and supplies current to operate the node aswell as current to power input devices. Some InterlinkBT® stations require an additional 24 VDC auxiliary power to supplycurrent for the outputs.

DeviceNet allows for Peer-to Peer data exchange (in which a DeviceNet product can produce and consume messages) andMaster/Slave operation (called the Predefined Master/Slave Connection Set).

Maximum System Extension

The branches can be up to 6 meters (20 ft) long, but thetotal length of all branches depends on the baud rate.A DeviceNet bus line consists of a scanner and at leastanother device. Do not exceed the maximum number of 64devices (including the scanner).

Mixed Operation with Other Devices

Within a DeviceNet structure, BL67 can be used in conjunc-tion with standardized DeviceNet fieldbus devices fromvarious manufacturers.

Page 9: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 9

2

DeviceNet™

Maximum size of the BL67 station

A BL67 station consists of a gateway forDeviceNet and a maximum of 32 electronicmodules (approximately 1 meter of din rail,including end bracket and end plate).

When using mixed systems (digital, analog, and serial modules together in one system), determining the number of modules thatare supported can become complicated. Maximum system size depends on a number of factors, such as : overall I/O data size,diagnostic data size, parameterization (or configuration) data size, and power requirements.

To determine exactly if a given system will work:1) Build the system using the I/Oassistant software2) Click on “Station” and then “Verify”The I/Oassistant will return “No Error” if the configuration is within total limits.

To quickly estimate if a system will work:Add up the fractional usage of each module. For example, consider a system with the following: 10 of the 8 DI modules 2 of the 1 RS232 modules 8 of the 2 AI-TC modules

- For the 8 DI we are using 10 out of 32 possible or 31.2 % of the total system resources- For the 1 RS232 we are using 2 out of 15 possible or 13.3% of the total system resources- For the 2 AI-TC modules we are using 8 out of 32 possible or 25% of the total system recources

Adding all the percentages together equals 69.5% which is less than 100%; this system will work.

Note: This simple aproach is a worst case approximation. Often you can build a system slightly larger than shown by this “esti-mate”. Use the I/Oassistant to determine the exact system limitations.

Digital inputs, 8 DIDigital outputs, 8 DOAnalog inputs, 2 AIAnalog outputs, 2 AO-IAnalog outputs, 2 AO-V1RS232

Module TypeChannelMaximum

ModuleMaximum

25625664645015

323232322515

Page 10: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588010

BL67 Power Distribution

Power Overview

The power supply to a BL67 station is fed via the powerconnector on the PROFIBUS® gateway or directly from thenetwork on the DeviceNet™ gateway.Power feeder modules can be added to the system at anypoint. Power feeder modules will provide a fresh isolated supplyof power to all I/O connected to their right.

Internal Power Consumption Via Module Bus

The number of BL67 modules that can be supplied via theinternal module bus depends on the respective nominalcurrent IMB of the individual modules on the module bus. Thesum total of the nominal current inputs of the connected BL67modules must not exceed 1.5 A. If the I/Oassistant softwareis used, an error message is generated automatically via the<Station - Verify> as soon as the system supply via themodule bus is no longer sufficiently guaranteed.

1) The sum of these currents must be less than 1.5 amps. This is only a concern when using the 1RS232 electronic module.2) The sum of these currents is drawn from DeviceNet, or VI on the PROFIBUS® gateway.3 & 4) The sum of these currents are drawn from the gateway or power feeding module.

Nominal Current Consumption

The following table offers an overview of the nominal internal current consumption of the different BL67 types on the module bus:

To calculate current draw on DeviceNet:-Add IMB(24) for all modules, then add VI and VO for electronic modules to the left of the first power feed module.-Then add the current draw of the I/O devices.

To calculate current draw on PROFIBUS® Gateway power connector for VI:-Add IMB for all modules, then add VI current for all modules to the left of the first power feed module.-Then add the current draw of the input devices.

For VO add the VO current for all modules to the left of the first power feed module.-Then add the current draw of output devices themselves.

VMB = Module Bus PowerVI = Input PowerVO = Output PowerIMB = Module Bus CurrentIMB(24) = Effective Current Draw from Gateway at 24 VDC Supply

Module Nominal 1)Current at 5 V IMB

Gateway PROFIBUS®-DPGateway DeviceNet™

BL67-PF-24VDCBL67-4DI-PBL67-8DI-PBL67-4DO-0.5A-PBL67-4DO-2A-PBL67-8DO-0.5A-PBL67-2AI-VBL67-2AI-IBL67-2AI-TCBL67-2AI-PTBL67-2AO-IBL67-2AO-VBL67-1RS232

- -< 30 mA< 30 mA< 30 mA< 30 mA< 30 mA< 30 mA< 35 mA< 35 mA< 35 mA< 45 mA< 40 mA< 60 mA< 100 mA

Effective Draw 2)from Gateway at 24VDC IMB (24)

Nominal 3)Current from VI

Nominal 4)Current from VO

<150 mA<100 mA< 9 mA< 9 mA< 9 mA< 9 mA< 9 mA< 9 mA< 10 mA< 10 mA< 10 mA< 13 mA< 12 mA< 17 mA< 28 mA

< 12 mA< 12 mA< 30 mA< 45 mA

< 50 mA

< 100 mA< 100 mA< 100 mA

< 40 mA< 40 mA

< 50 mA< 50 mA

Page 11: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 11

2

BL67 Power Distribution

DeviceNet™ System

System Power

Field Power

PROFIBUS® System

System Power

Field Power

A power feeder module provides a newisolated power segment for all modules toits right.

VI, Vo, VMB from Poweron Gateway

VMB(5V)

VI Vo

4A

VOVI

4A

Isolation of Field Power VI, VO

VMB(24V)

IMB(5V)

IMB(24V)II

IO

II

IO

VI, VO, VMBfrom DeviceNet

VI Vo

4A

VoVI

4A

Isolation of Field Power VI, VO

A power feeder module provides a newisolated power segment for all modules toits right.

VMB(5V)

VMB(24V)

IMB(5V)

IMB(24V) II

IO

II

IO

VMB = Module Bus PowerVI = Input PowerVO = Output Power

IMB(5V) < 1.5AII < 4A (protected)

IO < 8A

VMB = Module Bus PowerVI = Input PowerVO = Output Power

IMB(5V) < 1.5AII < 4A (protected)

IO < 8A

Isolation

Isolation

Page 12: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588012

Dimensions

Page 13: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 13

2

Environmental Conditions

General Environmental

via optocoupler32 °F to +131 °F (0 to +55 °C)-13 °F to +185 °F (-25 to +85 °C)5 to 95 % (indoor), noncondensing1.0g 5-100Hz15gIP 67, NEMA 1, 3, 4, 12, 13according to EN 61131-2PC-V0 (Lexan), Nickel plated brass

Potential isolationOperating temperatureStorage temperatureRelative humidityVibrationShockProtection classElectromagnetic compatibility (EMC)Housing Material

Not Intended for these Environments

• Continuous submersion

• 100 percent humidity

• Outdoors

• High pressure washdown

Intended Application Environments

• The BL67 does not need an enclosure

• Mount directly on machine or conveyor

• Rugged design provides protection against dirt, dust, and liquids

CEUL (Pending)CSA (Pending)

Approvals

NOTE: For higher levels of protection consider fully potted AIM™ stations

Page 14: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

14 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - GatewaysDeviceNet™

Gateway overview

• The gateway connects the BL67 station to DeviceNet• The gateway exchanges data between the BL67 station and the DeviceNet scanner• The connection to DeviceNet is made via a 5-pin minifast® connector• LEDs indicate supply voltage, group diagnostics and bus errors• End plate included

BL67 DeviceNet™ Gateway BL67-GW-DN

Supply voltagePermissible rangeNominal current consumptionService interfaceConnection technology fieldbusTransmission speedDeviceNet address set usingDeviceNet address range

24 VDC (from DeviceNet)11-26 VDC100 mA (see page 10 for details)PS/2 socketminifast® IP67 connector125/250/500/kBits/s2 rotary switches0 to 63

Page 15: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

15InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - GatewaysDeviceNet™ - Pinout and Accessories

Cordset: Male and Female minifast®

connectors use RSM RKM 579-*M

Tee: Male and Female minifast®

connectors use RSM 2RKM 57

1= Shield2 = V+3 = V -4 = CAN_H5 = CAN_L

5-pin minifast®

Male Female

Through Bus

Gateway Pinout Accessories

* indicates length in meters

• Set-button: press to learn existing configuration

• Service-interface for I/Oassistant: cable part number is XN-PS2-CABLE• Rotary address switch

• Data rate switch: 125/250/500/Auto kBits/s

Settings-I/Oassistant, transfer rate, addressing

BL67-GW-DN

Page 16: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

16 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - GatewaysPROFIBUS®-DP

Gateway Overview

• The gateway connects the BL67 station to PROFIBUS®-DP• The gateway exchanges data between the BL67 station and the PROFIBUS®-DP master• The connection to PROFIBUS®-DP is made via 2 eurofast® connectors• 3 rotary switches for setting the PROFIBUS®-DP station address (001-125)• LEDs indicate supply voltage, group or bus errors• End plate included

24 VDC via 5-pin minifast® connector18-30 VDCaccording to EN 61131-2<150 mA (see page 10 for details)PS/2 socketeurofast® IP67 connectorsmax. 12 MBit/s3 rotary switchesvia eurofast® connectors5 Bytes3 Bytes001 to 125

BL67 PROFIBUS®-DP Gateway BL67-GW-DP

Supply voltagePermissible rangeResidual rippleNominal current consumption from Vinput

Service interfaceConnection technology fieldbusTransmission speedPROFIBUS®-DP addressingPROFIBUS®-DP connectionNumber of parameter bytesNumber of diagnostic bytesAddress range for PROFIBUS®-DP

Page 17: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

17InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - GatewaysPROFIBUS®-DP - Pinout and Accessories

Cordset: Male minifast® connector use RKM 50-*M

Tee: Male minifast® connector use RSM 2RKM 50

Wiring diagram for BL67-GW-DP

Cordset: Male and Female eurofast®

connectors use RSSW RKSW 456-*M

Tee: Male and Female eurofast®

connectors use RKSW 2RSSW 45

1 = 5 VDC2 = Bus - A3 = Bus GND4 = Bus - B5 = Shield

1 = GND2 = GND3 = PE4 = Vinputs

5 = Voutpus

5-pin eurofast®

5-pin minifast®

Gateway Pinout Accessories

Male

FemaleMale

* indicates length in meters

Settings-I/Oassistant, transfer rate, addressing

• Service-Interface for I/Oassistant: cable part number is XN-PS2-CABLE• Setting PROFIBUS® address: 1-125

BL67-GW-DN

Page 18: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

18 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - Power Distribution ModulePower Feeder Module with Diagnostics

Module overview

• Supply the field with 24 VDC• Used to create isolated I/O groups• LEDs indicate system and field supply as well as diagnostics

Power Feeder Module with Diagnostics BL67-PF-24VDC

Electronic moduleNominal voltagePermissible rangeNominal current from module bus IMB

Maximum current Voutput

Maximum current Vinput

Diagnostic data

Base module

24 VDC18 to 30 VDC< 30 mA10 Amps not limited, output electronicsmodules limit this individually4 Amps short circuit protected1 Byte (overcurrent,undervoltage Vinput,undervoltage, Voutput)BL67-B-1RSM

Page 19: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

19InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - Power Distribution ModuleBase Module, Pinout and Accessories

Cordset: Male minifast® connector use RKM 50-*M

5-pin minifast®

1= GND2= GND3= PE4= Vinputs

5= Voutputs

Male

Pinout AccessoriesBase Module

* indicates length in meters

BL67-B-1RSM

minifast®, 1 Connector

Page 20: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

20 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - Digital Input Modules4DI, 24 VDC

Module overview

• Digital input for 24VDC PNP 3-wire sensors• 4 channels, positive switching• Electronics galvanically isolated from the field level via optocoupler• LEDs for indicating status and diagnostics

Digital Input Module BL67-4DI-P

424 VDC< 40 mA< 30 mA< 250 mW

< 4.5 V7 to 9 V-20 to 5 mA< 1.5 mA2.1 to 3.7 mA

max. 1000 VDCBL67-B-2M12BL67-B-2M12-PBL67-B-4M12BL67-B-4M8

Electronic moduleNumber of channelsNominal voltage from power feed Vinput

Nominal current from power feed Vinput

Nominal current from module bus IMB

Power loss of the module, typicalInput voltage, nominal value at 24 VDC

Low levelHigh level

Input current IinLow levelHigh level

Isolation voltageUTMB (module bus/field)

Base module

Page 21: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

21InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - Digital Input ModulesBase Module, Pinout and Accessories

* indicates length in meters

5-pin eurofast® Cordset: Sensor with 2 Signals use RK 4.4T-*-RS 4.4T

Sensor with 2 Signals

Splitter: Splitter with 2 Sensors use VBRS 4.4-2RK 4T-*/*

Splitter and 2 Sensors

1= Vinput

2 = Input B3 = GND4 = Input A5 = PE

Cordset: Single Sensor use RK 4.4T-*-RS 4.4T

1= Vinput

2 = N/C3 = GND4 = Input A5 = PE

Single Sensor

5-pin eurofast®

Cordset: Single Sensor use PKG-3M-*-PSG 3M

1= Vinput

3 = GND4 = Input

3-pin picofast®

Single Sensor

BL67-B-4M8

Pinout AccessoriesBase Module

picofast®, 4 Connectors

Pinout AccessoriesBase Module

eurofast®, 4 Connectors

BL67-B-4M12

PinoutBase Module

eurofast®, 2 Connectors

BL67-B-2M12 -Standard

BL67-B-2M12-P -Paired

Accessories

Page 22: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

22 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - Digital Input Modules8DI, 24 VDC

824 VDC< 40 mA< 30 mA< 250 mW

< 4.5 V7 to 9 V-20 to 5 mA< 1.5 mA2.1 to 3.7 mA

max. 1000 VDCBL67-B-4M12BL67-B-4M12-PBL67-B-8M8

Module overview

• Digital input for 24 VDC PNP 3-wire sensors• 8 channels, positive switching• Electronics galvanically isolated from the field level via optocoupler• LEDs for indicating status and diagnostics

Digital Input Module BL67-8DI-P

Electronic moduleNumber of channelsNominal voltage from power feed Vinput

Nominal current from power feed Vinput

Nominal current from module bus IMB

Power loss of the module, typicalInput voltage, nominal value at 24 VDC

Low levelHigh level

Input current IinLow level ILHigh level IH

Isolation voltageUTMB (module bus/field)

Base module

Page 23: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

23InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - Digital Input ModulesBase Module, Pinout and Accessories

1= Vinput

2 = Input B3 = GND4 = Input A5 = PE

Cordset: Sensor with 2 Signals use RK 4.4T-*-RS 4.4T

Sensor with 2 Signals

Splitter: Splitter with 2 Sensors use VBRS 4.4-2RK 4T-*/*

5-pin eurofast®BL67-B-4M12 -Standard

BL67-B-4M12-P -Paired

Splitter and 2 Sensors

eurofast®, 4 Connectors

* indicates length in meters

Cordset: Single Sensor use PKG-3M-*-PSG 3M

1= Vinput

3 = GND4 = Input

3-pin picofast®

Single Sensor

* indicates length in meters

BL67-B-8M8

Pinout AccessoriesBase Module

Pinout AccessoriesBase Module

picofast®, 8 Connectors

Page 24: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

24 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - Digital Output Modules4 DO, 24 VDC

Digital Output Module BL67-4DO-0.5A-P BL67-4DO-2A-P

WWWWW

424 VDC< 100 mA< 30 mA< 1.5 W

min. L+ (-1 V)

0.5 A0.6 A (acc. to IEC 6 11 31-2)max. 190 m

< 3 ms< 3 ms48 to 1 k100 %

< 4 ms< 10 smin.10 s/max. 60 s

resistive and inductive loadsas well as lamp loadsmin. 483 W

200 Hz2 Hz20 HzShort circuit/per channelBL67-B-2M12BL67-B-2M12-PBL67-B-4M12BL67-B-4M8

WWWWW WWWWW

WWWWW

424 VDC< 100 mA< 30 mA< 1.5 W

min. L+ (-1 V)

2 Amax. 2.4 A (acc. to IEC 6 11 31-2)max. 50 m

< 3 ms< 3 ms12 to 1 k100 %

< 4 ms< 10 smin.10 s/max. 60 s

resistive and inductive loadsas well as lamp loadsmin. 1210 W

200 Hz2 Hz20 HzShort circuit/per channelBL67-B-2M12BL67-B-2M12-PBL67-B-4M12BL67-B-4M8

WWWWW WWWWW

WWWWW

Module overview

• Digital output, 24 VDC• 4 channels, positive switching• 0.5A or 2A rated current• Electronics galvanically isolated from the field level via optocoupler• LEDs indicate status and diagnostics

WWWWW WWWWW

Electronic moduleNumber of channelsNominal voltage from power feed Voutput

Nominal current from power feed Voutput

Nominal current from module bus IMB

Power loss of the module, typicalOutput voltage (loaded)

High levelOutput current

High level IA (nominal value)High level IAMAX

Switch-on resistance RON

Delay at signal changeand resistive load (RLO < 1 k )

from low to high levelfrom high to low levelLoad impedance range

Synchronization factorSwitching off characteristic KA

(for 4DO-0.5A) (for 4DO-0.5A) (for 4DO-0.5A) (for 4DO-0.5A) (for 4DO-0.5A) ( for 4DO-2A)( for 4DO-2A)( for 4DO-2A)( for 4DO-2A)( for 4DO-2A) IOUT > 1.5 A IOUT > 6 A 1.0 A < IOUT < 1.5 A 4 A < IOUT < 6 A 0.6 A < IOUT > 1.0 A 2.4 A < IOUT > 4 A

Load Type

Load impedance, resistive RLO

Lamp load RLL

Switching frequencyResistive loadInductive loadLamp load

Diagnostic DataBase module

Page 25: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

25InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - Digital Output ModulesBase Module, Pinout and Accessories

* indicates length in meters

Pinout AccessoriesBase Module

eurofast®, 4 Connectors

BL67-B-4M12 Cordset: Single Output use RK 4.4T-*-RS 4.4T

Field Wireable: Single Output use BS8141-0

Single Output

5-pin eurofast®

1 = Vinput

2 = N/C3 = GND4 = Output5 = PE

PinoutBase Module

eurofast®, 2 Connectors

BL67-B-2M12 -Standard

BL67-B-2M12-P -Paired

Accessories

Cordset: Dual Output use RK 4.4T-*-RS 4.4T

Splitter: Dual Output use VB2-RS 4.5T-*/2VAS 22-A528-*/* (“A” Style valve plug, other’s available)

Field Wireable: Dual Output use BS8141-0

1 = Vinput

2 = Output B3 = GND4 = Output A5 = PE

5-pin eurofast®

Dual Output

Cordset: Single Output use PKG-3M-*-PSG 3M

Field Wireable: Single Output use BS5131-0

Pinout AccessoriesBase Module

picofast®, 4 Connectors

1 = Vinput

3 = GND4 = Output

3-pin picofast®BL67-B-4M8

Single Output

Page 26: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

26 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - Digital Output Modules8 DO, 24 VDC

824 VDC<100 mA< 30 mA< 1.5 W

min. L+ (-1V)

0.5 A0.6 A (according to IEC 61131-2)max. 190 m

< 3 ms< 3 ms48 to 1k100 %

< 4 ms< 10 smin. 10 s/max. 60 sresistive and inductive loadsas well as lamp loadsmin. 48WWWWW3 W

200 Hz2 Hz20 HzShort circuit, per channelBL67-B-4M12BL67-B-4M12-PBL67-B-8M8

Electronic moduleNumber of channelsNominal voltage from power feed Voutput

Nominal current from power feed Voutput

Nominal current from module bus IMB

Power loss of the module, typicalOutput voltage (loaded)

High levelOutput current

High level IA (nominal value)High level IAMAX

Load resistance RON

Delay at signal changeand resistive load (RLO < 1 )

from low to high levelfrom high to low levelLoad impedance range

Synchronization factorSwitching off characteristic KA

IOUT > 1.5 A1.0 A < IOUT < 1.5 A0.6 A < IOUT > 1.0 A

Connectable are

Load impedance, resistive RLO

Lamp load RLL

Switching frequencyResistive loadInductive loadLamp load

Diagnostic DataBase module

Digital Output Module BL67-8DO-0.5A-P

WWWWW

Module overview

• Digital output signals 24 VDC• 8 channels, positive switching• 0.5 A rated current• Electronics galvanically isolated from the field level via optocoupler• LEDs indicate status and diagnostics

WWWWW

WWWWWWWWWW

Page 27: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

27InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - Digital Output ModulesBase Module, Pinout and Accessories

* indicates length in meters

Pinout AccessoriesBase Module

Cordset: Dual Output use RK 4.4T-*-RS 4.4T

Splitter: Dual Output use VB2-RS 4.5T-*/2VAS 22-A528-*/* (“A” Style valve plug, other’s available)

Field Wireable: Dual Output use BS8141-0

1 = Vinput

2 = Output B3 = GND4 = Output A5 = PE

5-pin eurofast®

Dual Output

Pinout AccessoriesBase Module

picofast®, 8 Connectors

Cordset: Single Output use PKG-3M-*-PSG 3M

Field Wireable: Single Output use BS5131-0

1 = Vinput

3 = GND4 = Output

3-pin picofast®

Single Output

* indicates length in meters

BL67-B-4M12-P -Paired

BL67-B-4M12 -Standard

BL67-B-8M8

eurofast®, 4 Connectors

Page 28: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

28 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - Analog Input Modules2AI-I (0/4 to 20 mAmps),2AI-V (-10/0 to +10 Volts)

Module overview

• Analog input signals• 2 channel current or voltage• Electronics galvanically isolated from the field level via optocoupler• LEDs indicate diagnostics

224 VDC< 12 mA< 35 mA< 1 W

-10/0 to +10 VDC35 V continuous> 98.5 k> 50 Hz< 0.2 %0.05 %< 150 ppm/°C from end value16 BitDelta sigma16 Bit signed integer /12 Bit signed integer left-justified /1 Byte per channel-16/12 bit data- -10 to +10V/ 0 to 10V-Suppress/enable diagnostics-Activate/deactivate channel1 Byte per channel-over/under voltage

BL67-B-2M12

Analog Input Module BL67-2AI-I

224 VDC< 12 mA< 35 mA< 1 W0/4 to 20 mA50 mA

<125> 50 Hz< 0.2 %0.05 %< 300 ppm/°C from end value16 BitDelta sigma16 Bit signed integer /12 Bit full-range left-justified1 Byte per channel-16/12 bit data- 0 to 20/4 to 20mA-Suppress/enable diagnostics-Activate/deactivate channel1 Byte per channel-Over/under current-Short circuitBL67-B-2M12

BL67-2AI-V

WWWWW W W W W W

Electronic moduleNumber of channelsNominal voltage from power feed Vinput

Nominal current from power feed Vinput

Nominal current from module bus IMB

Power loss of the module, typicalInput currentMax. input currentInput voltageMax. input voltageInput resistance (burden)Cutoff frequency (-3 dB)Basic error at 23 °CRepeat accuracyTemperature coefficientResolution of A/D converterMeasuring principleMeasurement value representation

Parameter data

Diagnostic data

Base module

Page 29: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

29InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - Analog Input ModulesBase Module, Pinout and Accessories

Cordset: Single Sensor use RK 4.4T-*-RS 4.4T

1 = Vinput

2 = AIN +3 = GND4 = AIN -5 = PE

Single Sensor

5-pin eurofast®

Pinout AccessoriesBase Module

* indicates length in meters

BL67-B-2M12

eurofast®, 2 Connectors

Cordset 4-wire: No Drain, No Shield, Single Sensor use RK 4.4T-*-RS 4.4T

Cordset 5-wire: Drain and Shield, Single Sensor use RK 4.5T-*-RS 4.5T/S653

Page 30: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

30 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - Resistive Thermal Device (RTD) Input Module2 AI-PT

Module overview

• RTD temperature inputs: Pt100, Pt200, Pt500 and Pt1000 as well as nickel sensors Ni100 and Ni1000• 2- or 3-wire connections• Electronics galvanically isolated from the field level via optocoupler• LEDs indicate diagnostics

RTD Input Module BL67-2AI-PT

224 VDC< 30 mA< 45 mA< 1 W< 1 mA> 30 VDCaccording to DIN IEC 751according to DIN 43 76016 Bit signed integer /12 Bit full-range left-justified< 0.1 %< 0.1 %< 0.2 %0.05 %< 300 ppm/°C from end value< 130 ms per channel

Pt100, Pt200, Pt500, Pt1000Ni100, Ni1000- 50/60 Hz filter- 16/12 bit data- Enable/suppress diagnostics- Activate/deactivate channel- RTD type- 2-wire/3-wire- Over/under range- Open circuit- Short circuitBL67-B-2M12

Electronic moduleNumber of channelsNominal voltage from power feed Vinput

Nominal current from power feed Vinput

Nominal current from module bus IMB

Power loss of the module, typical PMAX

Measurement currentDestruction limitPlatinum sensorsNickel sensorsMeasurement value representation

Offset errorLinearityBasic error at 23 °CRepeat accuracyTemperature coefficient TK

Cycle timeConnectable sensors

Platinum sensorsNickel sensors

Parameter data

Diagnostic data

Base module

Page 31: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

31InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - Resistive Thermal Device Input ModuleBase Module, Pinout and Accessories

Cordset: Single Sensor use RK 4.4T-*-RS 4.4T

Pinout Accessories

1 = S +2 = AIN +3 = GND4 = AIN -5 = PE

Single Sensor

5-pin eurofast®

Base Module

* indicates length in meters

BL67-B-2M12

eurofast®, 2 Connectors

Cordset 4-wire: No Drain, No Shield, Single Sensor use RK 4.4T-*-RS 4.4T

Cordset 5-wire: Drain and Shield, Single Sensor use RK 4.5T-*-RS 4.5T/S653

Page 32: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

32 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - Thermocouple Input Module2 AI-TC

Module overview

• Thermocouple input types: B, E, J, K, N, R, S and T• Electronics galvanically isolated from the field level via optocoupler• Internal or remote cold junction compensation• LEDs indicate diagnostics

Thermocouple Input Module BL67-2AI-TC

Electronic moduleNumber of channelsNominal voltage from power feed Vinput

Nominal current from power feed Vinput

Nominal current from module bus IMB

Power loss of the module, typical PMAX

Max. input voltage UMAX (destruction limit)SensorsTemperature ranges

Type BType EType JType KType NType RType SType T

Voltage measurements (resolution)± 50 mV± 100 mV± 500 mV± 1 V

Measurement value representation

Offset errorLinearityBasic error at 23 °CRepeat accuracyTemperature coefficient TK

Cycle time

Parameter data

Diagnostic data

Base module

224 VDC< 30 mA< 35 mA< 1 W> 10 VDC (continuous)according to DIN IEC 584, Class 1, 2, 3

100 to 1820.0 °C-270 to 1000.0 °C-210 to 1200.0 °C-270 to 1370.0 °C-270 to 1300.0 °C-50 to 1760.0 °C-50 to 1540.0 °C-270 to 400.0 °C

< 2 µV< 4 µV< 20 µV< 50 µV16 Bit signed integer /12 Bit full-range left-justified< 0.1 %< 0.1 %< 0.2 %0.05 %< 300 ppm/°C from end valuetemperature: <130 ms per channel;voltage: <70 ms per channel- 50/60 Hz filter- 16/12 bit data- Enable/suppress diagnostics- Activate/deactivate channel- Thermocouple type- Over/under range- Open circuit- no Pt1000-sensor found(cold juntion compensation)BL67-B-2M12

Page 33: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

33InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - Thermocouple Input ModuleBase Module, Pinout and Accessories

Pinout Accessories

Cordset: Single Sensor use RK 4.4T-*-RS 4.4T

Field Wireable (built in Pt1000): Single Sensor use BL67-WAS5-THERMO

1 = CJ+2 = TC+3 = GND4 = TC-, CJ-5 = PE

Single Sensor

5-pin eurofast®

Base Module

* indicates length in meters

CJ = Cold Junction Compensator Pt1000TC = Thermocouple

eurofast®, 2 Connectors

BL67-B-2M12

Thermoelement can be replaced remotely using this configuration.

Cordset 4-wire: No Drain, No Shield, Single Sensor use RK 4.4T-*-RS 4.4T

Cordset 5-wire: Drain and Shield, Single Sensor use RK 4.5T-*-RS 4.5T/S653

RK 4.5T-*-RS 4.5T/S653 BL67-WAS5-THERMO

* indicates length in meters

BL67-B-2M12

Thermocouple Probe

Page 34: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

34 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Technical Data - Analog Output Modules2 AO-I (0/4 to 20 mAmps),2AO-V (-10/0 to +10 Volts)

Analog Output Module BL67-2AO-V

WWWWW

BL67-2AO-I

Module overview

• An analog output signal• 2 channel current or voltage• Electronics galvanically isolated via optocoupler• LEDs indicate diagnostics

WWWWW

Electronic moduleNumber of channelsNominal voltage from power feed Vinput

Nominal current from power feed Vinput

Nominal current from module bus IMB

Power loss of the module, typicalOutput voltage UA

Output currentBurden resistance

Resistive load RLO

Inductive load RLI

Capacitive load RLK

Short-circuit current IKTransmission frequency fT

Basic error at 23 °CRepeat accuracyOutput rippleTemperature coefficientSettling time (maximal)

Resistive loadInductive loadCapacitive load

Interference voltage suppressionCommon modeNormal mode

Interference between channelsData format

Parameter data

Base module

224 VDC< 50 mA< 60 mA< 1 W-10/0 to +10VDC

> 1 k

> 1 µF< 40 mA< 100 Hz0.2 %0.05 %0.02 %< 300 ppm/°C from end value

0.1 ms0.5 ms0.5 ms

> 90 dB> 70 dB> -50 dB16 Bit signed integer /12 Bit signed integer left-justified /12 Bit full-range left-justifiedNegative values are set to 0 when themeasurement range is 0 to +10 VDC.-16/12 bit data- 0 to +10 V/ -10 to +10V-substitute value-activate/deactivate channelBL67-B-2M12

224 VDC< 50 mA< 40 mA< 1 W

0/4 to 20 mA

< 450< 1 mH

< 200 Hz0.2 %0.05 %0.02 %< 150 ppm/°C from end value

0.1 ms0.5 ms

16 Bit signed integer /12 Bit full-range left-justifiedNegative values are set to0 mA or 4 mA.

-16/12 bit data- 0 to 20/4 to 20 mA-substitute value-activate/deactivate channelBL67-B-2M12

Page 35: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

35InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - Analog Output ModulesBase Module, Pinout and Accessories

Cordset: Single Sensor use RK 4.4T-*-RS 4.4T

Pinout Accessories

Single Sensor

5-pin eurofast®

1= Vinput

2 = AOUT +3 = GND4 = AOUT -5 = PE

Base Module

* indicates length in meters

BL67-B-2M12

eurofast®, 2 Connectors

Cordset 4-wire: No Drain, No Shield, Single Sensor use RK 4.4T-*-RS 4.4T

Cordset 5-wire: Drain and Shield, Single Sensor use RK 4.5T-*-RS 4.5T/S653

Page 36: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

36 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Serial Interface Module

Technical Data - Serial Interface Module1RS232

BL67-1RS232

Electronic moduleNumber of channelsVoltage supplyVoltage from module bus UMB

voltage rangeNominal current from power feed Vinput

Nominal current from module bus IMB

In/- Outputs transmission level active (URS1) transmission level inactive (URS0) common mode voltage range (UGL) transmission channels transmission rateRS232 cable lengthIsolation voltage UTMB (module bus/RS232)MemoryParameter data

Diagnostic Data

Base module

1via module bus5 VDC4.75 to 5.25 VDC < 50 mA100 mA

-15 to -3 VDC3 to 15 VDC-7 to 12 VDC2 (1/1) TxD and RxD, full duplex300 to 115200 Baudmax. 15 m

min. 1000 VDC128 Byte receive; 64 Byte transmit-Enable/suppress diagnostics-Data rate-Data bits-Parity-Stop bits-Data flow control-XON character-XOff character-Buffer overflow-Frame error-Data flow control error-Hardware failure-Parameterization errorBL67-B-1M12-8BL67-B-1M12

Module overview

• Transfer of serial RS232 data• Bit Transfer Rate: 300 Bit/s to 115200 Bit/s.• 7 or 8 bit format• Parity: None, even or odd• 1 or 2 stop bits• LEDs indicate data transfer status

Page 37: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

37InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

Technical Data - Serial Interface ModuleBase Module, Pinout and Accessories

* indicates length in meters

Cordset: 8-pin eurofast®

use RKC 8T-*-RSC 8T8-pin eurofast®

1 = RxD2 = TxD3 = RTS4 = CTS5 = GND6 = RTS7 = TxD8 = PE

eurofast®, 1 Connector

BL67-B-1M12-8

Pinout AccessoriesBase Module

5-pin eurofast®

1 = GNDMB

2 = TxD3 = GNDIO

4 = RxD5 = PE

Cordset: 4-pin eurofast®

use RS 4.4T-*-RK 4.4T

Pinout AccessoriesBase Module

BL67-B-1M12

eurofast®, 1 Connector

* indicates length in meters

Page 38: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

38 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

SoftwareI/Oassistant Software for the BL67 Station

Overview

Diagnostic software for• project planning• configuring BL67 station• monitoring I/O data• error logging

Functions

• Example projects

• Projects can be created on the monitor, structured and extended according to needs

• Selection of the required modules

• Plausibility tests of the station

• Off-line configuration of individual stations

• Detailed project documentation

• On-line help

• On-line configuration and parameterization of individual stations

• Creation of station-specific GSD files

• Commissioning station

• Reading and setting I/O data

• Diagnostic and error correction

• Download of new firmware into the BL67 gateway

• Resetting a BL67 station

• Error logging

Description

The I/Oassistant software package is an integralpart of the BL67 system. At every step in theprocess this software provides helpful informationin a clear, concise and easy to use manner.

During the initial design stages you can build an“off-line” system before you order a single pieceof hardware. The I/Oassistant will guide youthrough choosing the right base and electronicmodules. It will determine if the system is withinpower and data limitations. It will provide detaileddocumentation including: bills of material, overalldimensions, and labels. With real hardware, thesoftware is used to configure the BL67 station. Itcan be used to set any settable parameterincluding: thermocouple types, analog ranges,diagnostic reporting events and more. Once theBL67 system is installed and running, the I/Oassistant can be used to monitor I/O data.

One of the best features of the I/Oassistant is itsability to automatically down load a diagnostic logfrom a running BL67 station. One of the mostpowerful features of the BL67 station is that itautomatically logs all diagnostic messages - witha time and date stamp! This is great for thosehard to find intermittent problems.

Programming Cable

Part no. XN-PS2-CABLE

Page 39: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

39InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

3

For labeling electronic modules BL67-LABEL/DIN-A4 50STCK DIN A4 sheets, slice, perforated (laser print)

50 labels

Designation

Labels, Manuals and Programming Cable

Description Type

Labels

BL67 PROFIBUS® ManualBL67 DeviceNet™ ManualBL67 Electronic Modules

Manuals

Description of BL67-Gateway for PROFIBUS®-DPDescription of BL67-Gateway for DeviceNetDescription of fieldbus independent BL67 electronic modules

Programming Cable

For online configuration of BL67 Gateway XN-PS2-CABLE

Page 40: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588040

Notes

Page 41: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 41

4

DeviceNet™ Cables and Accessories

Page 42: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588042

Pre-molded Fieldbus Cables for DeviceNetTM

Standard lengths of pre-molded cordsets and bulk cable are listed below.

Cordsets Bulk Cable

metersmeters feet

0.3

0.5

1.0

1.5

2.0

2.5

3.0

4.0

5.0

6.0

8.0

10

15

20

25

30

40

50

1.0

1.6

3.3

4.9

6.6

8.2

9.8

13

16

20

26

33

49

66

82

98

131

164

30

75

150

225

300

- - -

Standard Cable Lengths

+ 4 % (or 50 mm) of length-0% of lengthwhichever is greater

Other lengths available upon request. Contact the factory at 1-888-546-5880.

Unit Conversions:1 meter = 3.28 feet1 meter = 39.8 inches

Tolerances:

feet

98

246

492

738

984

- - -

Page 43: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 43

4

DeviceNetTM – Thin Cable Specifications

Outer JacketData PairPower Pair BulkCable

Type

572AWM 2464

75°C 300V

PVC Gray7.3 mm(.285 in)

16.5 ΩΩΩΩΩ PE

NEC PLTCCEC AWM-I/II A/B FT4

DCR (/1000 ft) Insulation

AWGColor Code

DCR (/1000ft) Insulation

Material Color Nominal O.D.

RB50603-*M

PVC Gray7.3 mm(.285 in)

PVC Gray8.4 mm(.330 in)

16.5 ΩΩΩΩΩ PE

16.5 ΩΩΩΩΩ PE

2/22 AWGBlue/White

2/22 AWGBlue/White

2/22 AWGBlue/White

16.5 ΩΩΩΩΩ PVC

16.5 ΩΩΩΩΩ PVC

16.5 ΩΩΩΩΩ SR-PVC RB50629-*M

RB50651-*M

Cable that meets the requirements ofODVA Thin or Type 1 cable. This cable iscommonly used as drop cable to amaximum length of 6 meters (20 feet) ortrunk cable in networks up to a maximumlength of 100 meters (328 feet).

Foil22 AWG

Shields

TypeDrain Wire

Foil/Braid 22 AWG

Foil/Braid 22 AWG

Approvals

577AWM 2464

75°C 300V

NEC PLTCCEC AWM-I/II A/B FT4

NEC PLTC/CL2CEC CMG

AWGColor Code

2/22 AWGBlack/Red

2/22 AWGBlack/Red

2/22 AWGBlack/Red

578AWM 2464

75°C 300V

PVC Gray6.0 mm(.235 in)

16.5 ΩΩΩΩΩ PE

2/22 AWGBlue/White

16.5 ΩΩΩΩΩ PVC

RB50764-*MFoil (Data Only) 22AWG

NEC AWMCEC AWM-I/II A/B FT1

2/22 AWGBlack/Red

5715AWM 2095

80°C 300V

††

Data Rate MaximumTrunk Length

125 Kbaud

250 Kbaud

500 Kbaud

100M (328FT)

100M (328FT)

100M (328FT)

Drop LengthMaximum Cumulative

156M (512FT)

78M (256FT)

39M (128FT)

6M (20FT)

Available on some cable types.†

5724AWM 2464

75°C 300V

NEC AWMCEC AWM-I/II A/B FT1

2/24 AWGBlack/Red

24.9 ΩΩΩΩΩ PVC

2/24 AWGBlue/White

24.9 ΩΩΩΩΩ PE

PVC Light Gray5.7 mm(.224 in)

Foil24 AWG

RB51045-*M† † †

* indicates length in meters.

See page 42 for standard bulk cable lengths.†

† † † Maximum trunk length is 75 meters at all data rates.

† See page 106 for flexlife performance.†

Page 44: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588044

DeviceNetTM – Mid Cable Specifications

Cable that meets the requirements ofODVA Mid or Type III cable. Itprovides more flexibility when usedas a trunk cable up to a maximumlength of 300 meters (984 feet).

Outer JacketData PairPower Pair Shields

AWGColor Code

DCR (/1000 ft) Insulation

AWGColor Code

DCR (/1000ft) Insulation

Material Color Nominal O.D.

PVC Gray13.5 mm(.530 in)Aluminum Armor

2/18 AWGBlack/Red

6.7 ΩΩΩΩΩ PVC

2/20 AWGBlue/White

10.4 ΩΩΩΩΩ PE†††

Type TypeDrain Wire

Foil/Armor 20 AWG

NEC PLTC/CMCEC CMG

See page 42 for standard bulk cable lengths.†

Approvals

See page 106 for flexlife performance.

* indicates length in meters.

††

Armorfast Cable†††

PVC Gray8.4 mm(.330 in)

10.4 ΩΩΩΩΩ PE

2/20 AWGBlue/White

2/16 AWGBlack/Red

4.1 ΩΩΩΩΩ PVC

Foil 22 AWG

NEC PLTCCEC AWM-I/II A/B FT4

PVC Gray8.4 mm(.330 in)

10.4 ΩΩΩΩΩ PE

2/20 AWGBlue/White

2/17 AWGBlack/Red

5.2 ΩΩΩΩΩ PVC

PUR Gray8.4 mm(.330 in)

10.4 ΩΩΩΩΩ PE

2/20 AWGBlue/White

2/17 AWGBlack/Red

5.2 ΩΩΩΩΩ PVC

Foil22 AWG

Foil22 AWG

NEC AWMCEC AWM-I/II A/B FT1

NEC PLTCCEC AWM-I/II A/B FT4

5721A75°C 300V

5711AWM 2464

75°C 300V

5723AWM 20233

80°C 300V

5722AWM 2464

75°C 300V

Data Rate MaximumTrunk Length

125 Kbaud

250 Kbaud

500 Kbaud

300M (984FT)

250M (820FT)

100M (328FT)

A

RB50859-*M†††

RB50721-*M

RB50877-*M

RB50876-*M

††

Dwg

B

A

A

A

B

BulkCable PartNumber

Page 45: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 45

4

DeviceNetTM – Thick Cable Specifications

Flat Cable

Cable that meets the requirements ofODVA Thick or Type II cable. It providesthe most power to a network when usedas a trunk cable up to a maximumstandard cable length of 500 meters(1640 feet). Flat cable and TC ratedcables may be used as a trunk cable to amaximum length of 420M (1378FT).

Flat Profile is 19.3 mm (0.760 in) x 5.3 mm (0.210 in).

See page 42 for standard bulk cable lengths.

* indicates length in meters.

††

Outer JacketData PairPower Pair Shields

Type

PUR Light Gray10.4 mm(.409 in)

6.9 ΩΩΩΩΩ PE

DCR (/1000 ft) Insulation

AWGColor Code

DCR (/1000ft) Insulation

Material Color Nominal O.D.

PVC Light Gray11 mm(.435 in)

6.9 ΩΩΩΩΩ PE

2/18 AWGBlue/White

2/18 AWGBlue/White

3.2 ΩΩΩΩΩ PVC

3.2 ΩΩΩΩΩ SR-PVC

PVC Light GrayFlat Profile

4.1 ΩΩΩΩΩ PE

2/16 AWGBlue/White

4.4 ΩΩΩΩΩ PVC

PVC Light Gray13 mm (.515)

6.9 ΩΩΩΩΩ PE

2/18 AWGBlue/White

4.9 ΩΩΩΩΩ PVC

††

579AWM 2570

75°C 300V

NEC PLTC/CL2CEC CMB

AWGColor Code

2/15 AWGBlack/Red

2/15 AWGBlack/Red

2/16 AWGBlack/Red

2/16 AWGBlack/Red

TypeDrain Wire

Foil/Braid18 AWG

Foil/Braid 18 AWG

None

Foil/Braid 18 AWG

RB50652-*M

RB50787-*M

Approvals

575AWM20233

80°C 300V

NEC AWMCEC AWM-I/II A/B FT1

RB50633-*M

5720

75°C 600V

5713

75°C 300V

RB50793-*MNEC TC

NEC CL2CEC AWM-I/II A/B FT4

Data RateMaximum Standard Trunk Length

125 Kbaud

250 Kbaud

500 Kbaud

500M (1640FT)

250M (820FT)

100M (328FT)

Maximum TrunkLength (5713, 5720)

420M (1378FT)

200M (656FT)

100M (328FT)

BulkCable PartNumber

†Dwg

A

B

A

B

A

A

Page 46: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588046

DeviceNet™ Thin, Mid, and Thick Cable and Cordsets

RSM RSM 57x- *M

euro

fast

® (t

hin

, m

id o

nly

)

RSM RKM RSC

RSM

WSM

RKM

WKM

RSC

WSC

RKC

WKC

RSM WSM 57x- *M RSM RKM 57x- *M RSM WKM 57x- *M RSM RSC 57x- *M

WSM WSM 57x- *M WSM RKM 57x- *M WSM WKM 57x- *M WSM RSC 57x- *M

RKM RKM 57x- *M RKM WKM 57x- *M RKM RSC 57x- *M

WKM WKM 57x- *M WKM RSC 57x- *M

RSC RSC 57x- *M

min

ifas

Pin

(M

ale)

So

cket

(Fe

mal

e)P

in (

Mal

e)S

ock

et (

Fem

ale)

minifast®

Pin (Male) Socket (Female) Pin (Male)eurofast® (thin, mid only)

RSM 57x- *M WSM 57x- *M RKM 57x- *M WKM 57x- *M RSC 57x- *M

For stainless steel coupling nut:Change part number (RSM...to RSV, RSC...to RSCV).

Refer to the Cordset Builder on www.interlinkbt.com forassistance with cordset/cable combinations.

x indicates cable type.* indicates length in meters.

Standard cable lengths are 0.3, 0.5, 1.0, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0 ,6.0 ,8.0 ,10 ,15....50M. Consult factory for other lengths.

Armorfast cable is only available with straight minifast® connectors (RSM, RKM).

WSM

Example WSM RSC 57x- *M

1 Meter

WKM

Bare

Page 47: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 47

4

DeviceNet™ Thin, Mid, and Thick Cable and Cordsets

RSC FKFD 57x- *MRSC FSFD 57x- *MRSC RKFP 57x- *MRSC RSFP 57x- *MRSC WKC 57x- *MRSC RKC 57x- *MRSC WSC 57x- *M

WSC FKFD 57x- *MWSC FSFD 57x- *MWSC RKFP 57x- *MWSC RSFP 57x- *MWSC WKC 57x- *MWSC RKC 57x- *MWSC WSC 57x- *M

RKC FKFD 57x- *MRKC FSFD 57x- *MRKC RKFP 57x- *MRKC RSFP 57x- *MRKC WKC 57x- *MRKC RKC 57x- *M

WKC FKFD 57x- *MWKC FSFD 57x- *MWKC RKFP 57x- *MWKC RSFP 57x- *MWKC WKC 57x- *M

WSC RKC WKC RSFP RKFP FSFD FKFD

minifast® bulkheadPin (Male) Socket (Female) Pin (Male)

eurofast® bulkhead (thin only)Pin (Male) Socket (Female)Socket (Female)

eurofast® (thin and mid only)

WSC 57x- *M RKC 57x- *M WKC 57x- *M RSFP 57x- *M RKFP 57x- *M FSFD 57x- *M FKFD 57x- *M

RSM FKFD 57x- *MRSM FSFD 57x- *MRSM RKFP 57x- *MRSM RSFP 57x- *MRSM WKC 57x- *MRSM RKC 57x- *MRSM WSC 57x- *M

WSM FKFD 57x- *MWSM FSFD 57x- *MWSM RKFP 57x- *MWSM RSFP 57x- *MWSM WKC 57x- *MWSM RKC 57x- *MWSM WSC 57x- *M

RKM FKFD 57x- *MRKM FSFD 57x- *MRKM RKFP 57x- *MRKM RSFP 57x- *MRKM WKC 57x- *MRKM RKC 57x- *MRKM WSC 57x- *M

WKM FKFD 57x- *MWKM FSFD 57x- *MWKM RKFP 57x- *MWKM RSFP 57x- *MWKM WKC 57x- *MWKM RKC 57x- *MWKM WSC 57x- *M

Page 48: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588048

DeviceNet™ Open Connector Cordsets

x indicates cable type.* indicates length in meters.For stainless steel coupling nut: Change part number (RSM...to RSV, RSC...to RSCV).

Pinouts

RSM CBC5 57x-*M RKM CBC5 57x-*MWSM CBC5 57x-*M WKM CBC5 57x-*M

WSM BK52C 57x-*M WKM BK52C 57x-*MRKM BK52C 57x-*M

CBC5

BK52C

RSM WSMBare RKM WKM RSC

RSC BK52C 57x-*M

minifast® eurofast®

Pin (Male)Socket (Female)Pin (Male)

CBC5 57x-*M

BK52C 57x-*M RSM BK52C 57x-*M

Thin, Mid and Thick Thin & Mid only

RSC CBC5 57x-*M

1 = Black (-Voltage)

2 = Blue (CAN_L)

3 = Bare (Shield Drain)

4 = White (CAN_H)

5 = Red (+Voltage)

CBC5BK52C

1 = Black (-Voltage)

2 = Blue (CAN_L)

3 = Bare (Shield Drain)

4 = White (CAN_H)

5 = Red (+Voltage)

1 = Bare (Shield Drain Wire)

2 = Red (+ Voltage)

3 = Black (-Voltage)

4 = White (CAN_H)

5 = Blue (CAN_L)

Male eurofast®Female minifast® Female eurofast®Male minifast®

Page 49: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 49

4

See page 47 for bare lead options on bulkheads.

Refer to the Cordset Builder on www.interlinkbt.com for assistance with cordset/cable combinations.

Standard cable lengths are 0.3, 0.5, 1.0, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0 ,6.0 ,8.0 ,10 ,15....50M. Consult factory for other lengths.

Consult factory for daisy chain options.

DeviceNet™ Open Connector Cordsets

eurofast®

WKC CBC5 57x-*M RSFP CBC5 57x-*M RKFP CBC5 57x-*M FSFD CBC5 57x-*M

RKFP BK52C 57x-*MRSFP BK52C 57x-*M FSFD BK52C 57x-*M

RSFP RKFP FSFD FKFD

FKFD CBC5 57x-*M

FKFD BK52C 57x-*M

Socket (Female)Pin (Male) Pin (Male) Socket (Female) Pin(Male)

RKC CBC5 57x-*M

WKC BK52C 57x-*M RKC BK52C 57x-*M

WSC CBC5 57x-*M

WSC BK52C 57x-*M

RKC

eurofast® bulkheadminifast® bulkheadSocket (Female)

Thin and Mid only Thin, Mid and Thick Thin only

WSC WKC

DeviceNet™ Multi-Drop Harnesses

CBC5 VB2

VBRK Mini-Tee

Page 50: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588050

minifast® Cordset and Receptacle Connector Dimensions/Configuration

RKM

WSM WKM

RSFP Mounting InstallationRKFP

RSM

Pinouts

Male Female

1. Bare (Shield Drain Wire)2. Red ( + Voltage)3. Black ( - Voltage)4. White (CAN_H)5. Blue (CAN_L)

Page 51: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 51

4

eurofast® Cordset and Receptacle Connector Dimensions/Configuration

WSCWKC

RSC RKC

Mounting InstallationFKFDFSFD

Pinouts

Male Female

1. Bare (Shield Drain Wire)2. Red ( + Voltage)3. Black ( - Voltage)4. White (CAN_H)5. Blue (CAN_L)

Page 52: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588052

DeviceNetTM Terminating Resistors

eurofast® terminating resistor• internal resistor• male eurofast® connector

RSE 57-TR2

Type Applications Wiring diagram / Pin configuration

nominal voltage: 24 VDCinternal resistance: 120 Ω, 1/4 W

RKM 57-TR2

RKE 57-TR2

eurofast® terminating resistor• internal resistor• female eurofast® connector

nominal voltage: 24 VDCinternal resistance: 120 Ω, 1/4 W

minifast® terminating resistor• internal resistor• female minifast® connector

nominal voltage: 24 VDCinternal resistance: 120 Ω, 1/4 W

minifast® terminating resistor withvoltage monitoring

• internal resistor• male minifast® connector• led indication red-reverse polarity green-okay

nominal voltage: 24 VDCinternal resistance: 120 Ω, 1/4 W

nominal voltage: 24 VDCinternal resistance: 120 Ω, 1/4 W

minifast® terminating resistor• internal resistor• male minifast® connector

RSM 57VM-TR2

RSM 57-TR2

Page 53: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 53

4

DeviceNetTM Feed Through Connectors

Type ApplicationsFKM FS 57/M12

RSF RKF 57/22

Panel Cutout

minifast® Bulkhead Receptacle

• straight male/female feed-through• for use with DeviceNet minifast® cordsets

Closure Caps

minifast® Closure Cap

• mates to female receptacles• nylon

eurofast® Closure Cap

• mates to female receptacles• nylon

Type Applications

RSFK-BC (10/BAG)

VZ-3 (8/BAG)

eurofast® feed through connection, M 12 x 1

• straight male/female connector• for pre-molded eurofast® cables

Page 54: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588054

Flat Cable Connectors

eurofast® Flat Cable Connector

Flat cable connector tofemale eurofast® drop

Type Dimensions

FK 57-IDC

For stainless steel: Change part number (FK...to FKV).

FK 57-IDC ET

Includes connector, end termination kit, and splice kit.

minifast® Flat Cable Connector

Flat cable connector tofemale minifast® drop

For stainless steel: Change part number (RKF...to RKFV).

RKF 57-IDC

Type Dimensions

RKF 57-IDC ET

Includes connector, end termination kit, and splice kit.

Page 55: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 55

4

Circuit Board Connectors and Receptacles with Leadseurofast®

FKFD 57 PCB

FSFD 57 PCB

WFS 57 PCB

Panel Cut-out Board Layout (reference only**)

* indicates length in meters.** consult source drawing for board layout.Refer to page 42 for standard cable lengths.

Pinoutsminifast® Female

FKFD 57- *M

FSFD 57- *M

FK 57 PCB KIT

FS 57 PCB KIT

1. Bare2. (+Volt)3. (-Volt)4. (CAN_H)5. (CAN_L)

eurofast® Femaleeurofast® Male

minfast®

RKF 57 PCB KIT

RSF 57 PCB KIT

RKF 57- * M

RSF 57- *M

Panel Cut-out Board Layout (reference only**)

minifast® Male

Page 56: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588056

DeviceNetTM eurofast® Junction- Standard and with Voltage Monitoring

JBBS-57-E811Type Applications Wiring diagram / Pin configuration

8-port busstop® junction with voltagemonitoring

• bus in/bus out connections (7/8" minifast®)• eight eurofast® connectors for field connections• voltage monitoring provides low voltage (12.9V) and high voltage (25.6V) indication.

LED Indication(Lo) < 12.9V Amber(Ok) 12.9V-25.6V Green(Hi) > 25.6V Amber

JBBS-57-E812

Type Applications Wiring diagram / Pin configuration

8-port busstop® junction

• bus in/bus out connections (7/8" minifast®)• eight eurofast® connectors for field connections

Page 57: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 57

4

DeviceNetTM eurofast® Junction Tee

Pinouts

eurofast® Female1. Bare (Shield Drain Wire)2. Red (+Voltage)3. Black (-Voltage)4. White (CAN_H)5. Blue (CAN_L)

minifast® Male minifast® Female

Type Applications Wiring diagram / Pin configuration

4-port busstop® junction tee

• minifast ® bus in/bus out connections• four eurofast® device ports• for stainless steel connectors change part number to JTBS 57-E433

JTBS 57-E434

JTBS 57-E634

6-port busstop® junction tee

• minifast® bus in/bus out connections• six eurofast® device ports• for stainless steel connectors change part number to JTBS 57-E633

Page 58: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588058

DeviceNetTM minifast® Junction Tee

minifast® Male minifast® Female

Pinouts

1. Bare (Shield Drain Wire)2. Red (+Voltage)3. Black (-Voltage)4. White (CAN_H)5. Blue (CAN_L)

Type Applications Wiring diagram / Pin configuration

4-port busstop® junction tee

• minifast® bus in/bus out connections• four minifast® device ports• for stainless steel connectors change part number to JTBS 57-M433

JTBS 57-M434

JTBS 57-M634

6-port busstop® junction tee

• minifast® bus in/bus out connections• six minifast® device ports• for stainless steel connectors change part number to JTBS 57-M633

Page 59: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 59

4

Pinouts

eurofast® Female1. Bare (Shield Drain Wire)2. Red (+Voltage)3. Black (-Voltage)4. White (CAN_H)5. Blue (CAN_L)

minifast® Male minifast® Female

DeviceNetTM eurofast® Junction Tee with Voltage Monitoring

Type Applications Wiring diagram / Pin configuration

4-port busstop® junction tee withvoltage monitoring

• minifast ® bus in/bus out connections• four eurofast® device ports• for stainless steel connectors change part number to JTBS 57-E433• voltage monitoring provides low voltage (12.9V) and high voltage (25.6) indication.

Led Indication(Lo) < 12.9V Amber(Ok) 12.9-25.6V Green(Hi) > 25.6V Amber

JTBS 57VM-E434

JTBS 57VM-E634

6-port busstop® junction tee with voltagemonitoring

• minifast® bus in/bus out connections• six eurofast® device ports• for stainless steel connectors change part number to JTBS 57-E633• voltage monitoring provides low voltage (12.9V) and high voltage (25.6) indication.

Led Indication(Lo) < 12.9V Amber(Ok) 12.9-25.6V Green(Hi) > 25.6V Amber

Page 60: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588060

minifast® Male minifast® Female

Pinouts

1. Bare (Shield Drain Wire)2. Red (+Voltage)3. Black (-Voltage)4. White (CAN_H)5. Blue (CAN_L)

DeviceNetTM minifast® Junction Tee with Voltage Monitoring

Type Applications Wiring diagram / Pin configuration

4-port busstop® junction tee with voltagemonitoring

• minifast® bus in/bus out connections• four minifast® device ports• for stainless steel connectors change part number to JTBS 57-M433• voltage monitoring provides low voltage (12.9V) and high voltage (25.6) indication.

Led Indication(Lo) < 12.9V Amber(Ok) 12.9-25.6V Green(Hi) > 25.6V Amber

JTBS 57VM-M434

JTBS 57VM-M634

6-port busstop® junction tee with voltagemonitoring

• minifast® bus in/bus out connections• six minifast® device ports• for stainless steel connectors change part number to JTBS 57-M633• voltage monitoring provides low voltage (12.9V) and high voltage (25.6) indication.

Led Indication(Lo) < 12.9V Amber(Ok) 12.9-25.6V Green(Hi) > 25.6V Amber

Page 61: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 61

4

DeviceNetTM Conduit Adapter

Conduit BodiesCROUSE - HINDS Hub Size = 3/4

Shape

CCCCC

LBLBLBLBLB

LLLLLLLLLL

LRLRLRLRLR

Style

Form 8Mark 9

Form 8Mark 9

Form 8Mark 9

Form 8Mark 9

Part Number

C28C29

LB28LB29

LL28LL29

LR28LR29

The conduit adapter attaches to a standard conduit body for transition to minifast® or eurofast® connectors.

Gasket and mounting hardware included (8-32 x 1/2”).

Dimensions

Description

Check network layout to see if the terminator should be turned on. Default is to off position.

minifast® eurofast®

1-p

ort

2-p

ort

BCA 57-M123

BCA 57-M223 BCA 57-E223

BCA 57-E123

1 = Black (-Voltage)

2 = Blue (CAN_L)

3 = Bare (Shield Drain)

4 = White (CAN_H)

5 = Red (+Voltage)

Schematic

Trunk

Drop

Trunk

Drop

Drop

Page 62: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588062

VB2 junction• ready for eurofast®

branch and trunk cordsets• maximum 6 meter drop

DeviceNetTM eurofast® Drop Junctions

Part Number Definition

VB2-RKC57x-*M-FKM FSM

VB2-FKM/RKC RSC57x-*M/*M

VB2 junction with trunk line• reduced power and data branch• maximum 6 meter branch

Type Applications Wiring diagram / Pin configuration

VB2 junction with trunk line• ready for eurofast® trunk line• maximum 6 meter drop

J2

J1 J3

J2

J1 J3

J2

J1 J3

* indicates cable length.x indicates cable type.

C

B

A

x indicates cable type; thin and mid only.* indicates cable length.

x x

VB2-FKM/FKM/FSM 57

Page 63: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 63

4

DeviceNetTM eurofast® Bus Tees

eurofast® Branch• minifast® (7/8“) to eurofast®

(M12 x 1)• bus power and data branch

eurofast® Cordset Branch• minifast® (7/8“) to eurofast®

(M12 x 1) extension cable• available with all thin cables; limit 6 M branch• for right angle connector, change RKC to WKC

Type Applications Wiring diagram / Pin configuration

eurofast® Tee• eurofast® (M12 x 1) trunk and drop

RSM-FKM-RKM57

RSM RKC 57x-*M RKM 57

RSC 2RKC 57

* indicates cable length.x indicates cable type.

Page 64: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588064

Bus Drop, Power and Diagnostic Tees

For stainless steel coupling nuts: Change part number (RSM 2RKM..to RSV 2RKV..).

RSM 2RKM 57

RSM 2RKM 57-KF

RSM 2RKM 57-KM

Type Applications Wiring diagram / Pin configuration

RSM RKM 57 WSM 40 PST

RSM 2RKM 57 DGT

minifast® Drop Off Bus Line• full power and data drop• maximum 6 meter branch• standard keyway

minifast® Drop Off Bus Line• full power and data drop• maximum 6 meter branch• keyway facing female

minifast® Drop Off Bus Line• full power and data drop• maximum 6 meter branch• keyway facing male

busstop® Power Tee• provides segment power• includes reverse current protection

busstop® Diagnostic Tee• provides easy connection for diagnostic tools• tap protected with cover when not in use (not shown)

Page 65: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 65

4

Gender Changers and Elbow Connectors

For stainless steel coupling nuts: Change part number (RKM RKM.. to RKV RKV..).

Type Applications

RSM RSM 57

RKM RKM 57

WSM RKM 57

RSM 57-FK 4.5

Male minifast® Gender Changer• changes female cordset to male receptacle

Female minifast® Gender Changer• changes male cordset to female receptacle

minifast® Elbow• right angle male to female connector

minifast® to eurofast® Adapter• minifast male to eurofast female connector

not available in stainless steel.†

Page 66: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588066

FSV 57-*M / 14.75 RSFV 57-*M / 14.75

Device Gland Receptacles

* indicates cable length.Consult factory for availabilityof nickel plated brass.

1. Grey (Shield)2. Red (+ Voltage)3. Black (- Voltage)4. White (CAN_H)5. Blue (CAN_L)

eurofast® minifast®Selection Guide

M20 FSV 57-*M / M20FSV 57-*M / M20FSV 57-*M / M20FSV 57-*M / M20FSV 57-*M / M20 RSFV 57-*M / M20RSFV 57-*M / M20RSFV 57-*M / M20RSFV 57-*M / M20RSFV 57-*M / M20

1/2 - NPT FSV 57-*M / 14.5FSV 57-*M / 14.5FSV 57-*M / 14.5FSV 57-*M / 14.5FSV 57-*M / 14.5 RSFV 57-*M / 14.5RSFV 57-*M / 14.5RSFV 57-*M / 14.5RSFV 57-*M / 14.5RSFV 57-*M / 14.5

3/4 - NPT FSV 57-*M / 14.75FSV 57-*M / 14.75FSV 57-*M / 14.75FSV 57-*M / 14.75FSV 57-*M / 14.75 RSFV 57-*M / 14.75RSFV 57-*M / 14.75RSFV 57-*M / 14.75RSFV 57-*M / 14.75RSFV 57-*M / 14.75

FSV 57-*M / 14.5 RSFV 57-*M / 14.5

Male eurofast®Male minifast®

RSFV 57-*M / M20FSV 57-*M / M20

Page 67: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 67

4

Panel Mount Receptacles - minifast®, eurofast®

RKF 57 - *MRKF 57 - *MRKF 57 - *MRKF 57 - *MRKF 57 - *M RSF 57 - *MRSF 57 - *MRSF 57 - *MRSF 57 - *MRSF 57 - *M

FK 57 - *MFK 57 - *MFK 57 - *MFK 57 - *MFK 57 - *M FS 57 - *MFS 57 - *MFS 57 - *MFS 57 - *MFS 57 - *Meurofast®

minifast®

eurofast®

minifast® RKF 57x - *MRKF 57x - *MRKF 57x - *MRKF 57x - *MRKF 57x - *M RSF 57x - *MRSF 57x - *MRSF 57x - *MRSF 57x - *MRSF 57x - *M

FK 57x - *MFK 57x - *MFK 57x - *MFK 57x - *MFK 57x - *M FS 57x - *MFS 57x - *MFS 57x - *MFS 57x - *MFS 57x - *M

Selection Guide Female Male

Lea

ds

Cab

le

Panel locknuts: LN 1/2-14/10 (10 pieces) for RSF and RKF styles.

Receptacles also available with DeviceNet cable; see pages 43-45 for cable specifications.

Example: RSF 57x-*Mx indicates cable type (57 only for bare lead option).* indicates cable length.

Parts in photo represent solder cups only. For solder cup only order part number RKF 57, FS 57 etc.

For stainless steel add “V” to housing identifier. Example: RKF...to RKFV or FK...to FKV...

RKF 57 RSF 57

FS 57

Female minifast® Female eurofast®1. Grey (Shield)2. Red (+ Voltage)3. Black (- Voltage)4. White (CAN_H)5. Blue (CAN_L)

1 Meter

FK 57

Page 68: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588068

Typical Application

eurofast® System Module Junction

Note: See following page for descriptions of part numbers.

* indicates length in meters.

ApplicationsPart Number Schematic

System Module with TwoCircuit Groups• DeviceNet™ Circuit - Supplies DC power - Two Drops• Auxiliary Power - Supplies DC power - Category 2 E-stop - General Purpose M(achine)-stop

JBBS-57-SM01

Page 69: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 69

4InterlinkBT®

RSC CBC5 572-*M *-meter, DeviceNet™ 5-pin eurofast® connector to 5 combicon connectorRSM RKM 579-*M *-meter, full trunkline (bus line) DeviceNet cable, male/female molded endsRSF RKF 57/22 male/female, 5-pin minifast® through-wall connectorRKC 572-*M *-meter, 5-wire DeviceNet thin cable, female/tinned endsRSC 572-*M *-meter, 5-wire DeviceNet thin cable, male/tinned endsJBBS-57-SM01 System Module

TURCK

RS 4.5T-*M *-meter, 5-wire eurofast cable, male/tinned ends, 20 AWG,gry PVC, ground allRSF RKF 40/22 male/female, 4-pin minifast® through-wall connectorRSM RKM 46-*M *-meter, 4-wire, male/female molded minifast® cable, 16 AWG, yellow PVC jacketRKM 46-*M *-meter, 4-wire, female/tinned ends minifast® cable, 16 AWG, yellow PVC jacketS7-M relay base, DIN and panel mount,with relay locking tabC7-A20DX/24VDC w/S9-N relay, 24 VDC coil with free-wheeling diode, 10A, DPDT

Caution! Install with S9-N blank plug to disable Push-To-Test/Pull-To-Lock functions.

Specifications

* indicates cable length.

Pinouts-minifast®Dimensions

FemaleTrunk Left & Right

Female Aux PowerLeft & Right

MaleBus Power inAux Power in

1 = Shield2 = V+3 = V-4 = CAN_H5 = CAN_L

1 = V+2 = E-Stop +3 = E-Stop-4 = V-

1 = V+Right (Red)2 = V+Left (Green)3 = V-Left (White)4 = V-Right (Black)

RKM 46-*M

FemaleDropline Local

Female Shield

Male E-Stop

1 = Shield2 = Shield3 = Shield4 = Shield5 = Shield

1 = E-Stop -Right2 = E-Stop +Right3 = E-Stop -Left4 = E-Stop +Left

1 = Shield2 = V+3 = V-4 = Can_H5 = CAN_L

Pinouts-eurofast®

Page 70: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588070

Power Taps

SPTC2

Type Wiring diagram / Pin configuration

SPTT1

busstop® Power Tap with minifast® connectors• minifast® male to female bus connector• minifast® female power connector

busstop Power Tap with minifast® connectors• minifast® female to female bus connector• minifast® female power connector

busstop® Power Tap with terminal connectors• terminal strip bus connectors• terminal strip power connector

SPTC1

Bus Line Auxiliary Power

1. Shield2. + Voltage3. - Voltage4. CAN_H5. CAN_L

1. + Voltage2. - Voltage3. + Voltage4. - Voltage

Page 71: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 71

4

For stainless steel housing: Change part number (BS 4151...to BSV 4157 or B 4151...to BV 4157...).

minifast® 5-pin Field Wireable Connectors

Female minifast®

Rating: 9 A, 300 VDC

Male minifast®

Rating: 9 A, 300 VDC

Thin CableB 4151-0/9

Thick CableB 4151-0/13.5

Fem

ale

Mal

e

BS 4151-0/9 BS 4151-0/13.5

Accepts 6-8 mm cable. Accepts 10-12 mm cable.

Accepts 6-8 mm cable. Accepts 10-12 mm cable.

eurofast® 5-pin Field Wireable Connectors

Accepts 4-8 mm cable.

Straight Right Angle

Fem

ale

Mal

e

B 8151-0 B 8251-0

BS 8151-0 BS 8251-0

Accepts 4-8 mm cable.

Accepts 4-8 mm cable.Accepts 4-8 mm cable.

Male eurofast®Female eurofast®

Rating: 3 A, 36 VDC Rating: 3 A, 36 VDC

To connect thermocouples use the field wireable with built in cold junction compensation. Part number BL67-WAS5-THERMO.

Page 72: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588072

TURCK Power Cordsets for DeviceNet™ - minifast® Connectors

WSM RKM 46-1M

For stainless steel coupling nuts: Change part number (RSM..to RSV..).

minifast®

RSM 46-*M WSM 46-*M RKM 46-*M WKM 46-*M

RSM RSM 46-*M RSM RKM 46-*MRSM WSM 46-*M RSM WKM 46-*M

WSM WSM 46-*M WSM WKM 46-*M

RKM RKM 46-*M RKM WKM 46-*M

WKM WKM 46-*M

Pin (Male) Socket (Female)

Pin

(M

ale)

Soc

ket

(Fem

ale)

min

ifast

®

WSM RKM 46-*M

RSM WSM RKM WKM

RSM

RKM

Example

WKM

WSM

* indicates length in meters.

Standard cable lengths are 0.3, 0.5, 1.0, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0 ,6.0 ,8.0 ,10 ,15....50M.Consult factory for other lengths.

1 Meter

Page 73: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 73

4

Specifications for DeviceNet™ Systems

Dimensions Cordset Pinouts(per SAE-J-1738 A)

Station Pinouts(per EN 50 044)

Female minifast®

WKM WKM

Female minifast®

Male minifast®

RSMMale minifast®

RSM

RKM

Female minifast®Female minifast®

RKM

WSM

Male minifast® Male minifast®

WSM

Power Pair

NEC STOWCEC STOWFT2

DCR (/1000 ft) Insulation

4.3 ΩΩΩΩΩ PVC

Approvals AWGColor Code

4/16 AWGBk,Wh,Rd,Gn

Cable Type

46 AWM 2464

105°C 300V

Outer Jacket

PVC Yellow11 mm(.435 in)

Material Color Nominal O.D.

None

Shields

TypeDrain Wire

Bulk Cable

RF50538-*M

1. Black (-Voltage)2. White (E-)3. Red (+ Voltage)4. Green (E+)

1. Red (+ Voltage)2. Green (E+)3. White (E-)4. Black (-Voltage)

Color Codes

Page 74: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588074

TURCK Power Tees for DeviceNet™ - minifast® Connectors

For stainless steel coupling nuts: Change part number ( RSM 2RKM..to RSV 2RKV..).

Part Number Applications

minifast® Power Tee• standard keyway

RSM 2RKM 40

RSM 2RKM 40-KF

RSM 2RKM 40-KM

minifast® Power Tee• keyway facing male

minifast® Power Tee• keyway facing female

Page 75: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 75

4

TURCK eurofast® 4-pin Field Wireable Connectors

Male eurofast®Female eurofast®

Accepts 4-8 mm cable.

Straight Right Angle

Fem

ale

Mal

e

B 8141-0/PG 9 B 8241-0/PG 9

BS 8141-0/PG 9 BS 8241-0/PG 9

Accepts 4-8 mm cable.

Accepts 4-8 mm cable.Accepts 4-8 mm cable.

Rating: 4 A, 150 VDC Rating: 4 A, 150 VDC

Page 76: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588076

Notes

Page 77: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 77

4

PROFIBUS®-DP Cables and Accessories

Page 78: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588078

Standard lengths of pre-molded cordsets and bulk cable are listed below.

Other lengths available upon request. Contact the factory at 1-888-546-5880.

Unit Conversions:1 meter = 3.28 feet1 meter = 39.8 inches

Tolerances:

Pre-molded Fieldbus Cables for PROFIBUS®-DP

Cordsets Bulk Cable

metersmeters feet

0.3

0.5

1.0

1.5

2.0

2.5

3.0

4.0

5.0

6.0

8.0

10

15

20

25

30

40

50

1.0

1.6

3.3

4.9

6.6

8.2

9.8

13

16

20

26

33

49

66

82

98

131

164

30

75

150

225

300

- - -

Standard Cable Lengths

feet

98

246

492

738

984

- - -

+ 4 % (or 50 mm) of length-0% of lengthwhichever is greater

Page 79: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 79

4

Cable that meets the requirements ofEN50170-2-2:1996 for communicationsup to 12Mbaud.

Data Pair Shields

Type AWGColor Code

DCR (/1000ft) Insulation

Outer Jacket

Material Color Nominal O.D.

TypeDrain Wire

16.5 ΩΩΩΩΩ PE

PUR Purple8.1 mm(0.319 in)

Foil/Braid 22 AWG

2/22 AWGRed/Green

16.5 ΩΩΩΩΩ PE

PUR Purple8.0 mm(0.315 in)

Foil/Braid No Drain

2/22 AWGRed/Green

16.5 ΩΩΩΩΩ PE

2/22 AWGRed/Green

PVC Purple8.1 mm(0.319 in)

Foil/Braid 22 AWG

456AWM 20233 80°C 300V

NEC AWMCEC AWM-I/II A/B FT1

RB50683-*M

RB50708-*M

2/22 AWGRed/Green

16.5 ΩΩΩΩΩ PE

PVC Purple8.1 mm(0.319 in)

Foil/Braid 22 AWG RB50881-*M

458

AWM 20233 80°C 300V

4511

105°C 300V

NEC AWMCEC AWM-I/II A/B FT1

16.5 ΩΩΩΩΩ PE

PUR Plum8.1 mm(0.319 in)

2/22 AWGRed/Green

Foil/Braid 22 AWG

RB50692-*M

NEC PLTCCEC AWM-I/II A/B FT4

457

75°C 100V

NEC CMX

Approvals

455AWM 2464 75°C 300V

NEC PLTCCEC AWM-I/II A/B FT4

RB50672-*M

PROFIBUS®-DP Cable Specifications

* indicates length in meters.

See page 78 for standard bulk cable lengths.†

4510A

105°C 300V

† † See page 106 for flexlife performance.

Armorfast Cable† ††

2/22 AWGRed/Green

NEC PLTCCEC CM-CMG

16.5 ΩΩΩΩΩ PE

Aluminum Armor/PVC Purple 14.2 mm (.560 in)

RB50875-*MArmor Foil/Braid 22 AWG

††

††

† ††

Baud Rate (k baud)

Maximum Trunk Length

9.6 50093.7519.2 187.5 1500 12000

1200m 1200m 1200m 1000m 400m 200m 100m

Dwg†Bulk CablePart Number

A

A

A

A

A

B

B

A

Page 80: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588080

PROFIBUS®-DP Cables, Extensions, eurofast®

x indicates cable type.* indicates length in meters.Refer to the Cordset Builder on www.interlinkbt.com for assistance with cordset/cable combinations.

RSSW

RSSW

RKSW

RKSW

Pin

(M

ale)

Socket (Female)

So

cket

(Fe

mal

e)

Pin (Male)

euro

fast

®

eurofast®

RKSW 45x-*MRSSW 45x-*M WSSW 45x-*M WKSW 45x-*M

RSSW WSSW 45x-*MRSSW RSSW 45x-*M RSSW WKSW 45x-*MRSSW RKSW 45x-*M

WSSW WSSW 45x-*M

RKSW RKSW 45x-*M RKSW WKSW 45x-*M

WSSW WKSW 45x-*M

WKSW WKSW 45x-*M

WSSW RKSW 45x-*M

1 Meter

Standard cable lengths are 0.3, 0.5, 1.0, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0 ,6.0 ,8.0 ,10 ,15....50M. Consult factory for other lengths.

WSSW WKSW

WSSW

WKSW

Example WSSW RKSW 45x- 1M

Page 81: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 81

4

PROFIBUS®-DP Dimensions / Configuration

RKSWRSSW

1. N/C2. Green3. N/C4. Red5. Bare (shield drain)

Male Female

FKSDWEFSFDWE

WKSWWSSW

Pinouts

Page 82: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588082

PROFIBUS®-DP Cables, Extensions, eurofast®

RSSW WSSW

Socket (Female)Pin (Male)

9-P

in S

ub D

Co

nnec

tor

eurofast®

FieldWireable 45x

D9S

D9SM/T

D9S/T

SD9S

Ter

min

ato

rN

ode

Str

aig

htM

aste

r

D9S/T 45x-*M

SD9S 45x-*M

D9SM/T 45x-*M

D9S 45x-*M

WSSW D9S/T 45x-*MRSSW D9S/T 45x-*M

RSSW D9S RSSW 45x-*M-*M RKSW D9S RKSW 45x-*M-*MWSSW D9S WSSW 45x-*M-*M

RSSW D9SM/T 45x-*M WSSW D9SM/T 45x-*M

RSSW SD9S RSSW 45x-*M-*M WSSW SD9S WSSW 45x-*M-*M RKSW SD9S RKSW 45x-*M-*M

RKSW WKSW

RKSW D9S/T 45x-*M WKSW D9S/T 45x-*M

WKSW D9S WKSW 45x-*M-*M

RKSW D9SM/T 45x-*M WKSW D9SM/T 45x-*M

WKSW SD9S WKSW 45x-*M-*M

PROFIBUS-DP D9 Sub Connector

D9SM D9S or D9S/T SD9S

Schematic for RSSW D9S RKSW 45x-*M-*M-with termination switch off

Schematic for RKSW D9S/T 45x-*M-with termination switch on

D9 Sub Connector

x indicates cable type.* indicates length in meters.

Page 83: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 83

4

RSSW/RKSW FSSDWE FKSDWE FSSDWE/FKSDWE

FSSDWE D9S/T 45x-*M FKSDWE D9S/T 45x-*M

WSSW/WKSW

RSSW D9S RKSW 45x-*M-*M WSSW D9S WKSW 45x-*M-*M

RSSW SD9S RKSW 45x-*M-*M WSSW SD9S WKSW 45x-*M-*M FSSDWE SD9S FSSDWE

45x-*M-*M

FKSDWE SD9S FKSDWE

45x-*M-*M

FSSDWE SD9S FKSDWE

45x-*M-*M

FKSDWE D9SM/T 45x-*MFSSDWE D9SM/T 45x-*M

FSSDWE D9S FSSDWE

45x-*M-*M

FKSDWE D9S FKSDWE

45x-*M-*M

FSSDWE D9S FKSDWE

45x-*M-*M

Pin (Male) /Socket (Female)

eurofast® eurofast® bulkhead

Socket (Female)Pin (Male) Pin(Male)/Socket(Female)

PROFIBUS®-DP D9 Sub Connector Examples

x indicates cable type.* indicates length in meters.

FSSDWE D9S FKSDWE 45x-*M-*M

RSSW D9S RKSW 45x-*M-*M

PROFIBUS®-DP Cables, Extensions, eurofast®

Page 84: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588084

PROFIBUS®-DP Bus Tees

PROFIBUS-DP Bus Y-junction

RKSW 2RSSW 45

fully shielded eurofast® tee

PROFIBUS-DP tee (12 M baud), M 12x1

Dimensions Pin configuration Wiring diagram

S einfügen!eurofast® femaleeurofast® male

Dimensions Wiring diagramPin Configuration

eurofast® femaleeurofast® male

RKSW 2RSSW 45-0001

fully shielded eurofast® tee

PROFIBUS-DP tee (12 M baud), M 12x1

eurofast® femaleeurofast® male

Note: This part must be used when joining two tees together directly. A female terminating resistor will not work with this tee sincethere is no ground and power connection on the male side.

VB2/FSW/FKW/FSW 45

fully shielded eurofast®

PROFIBUS-DP tee (12 M baud), M 12x1

Page 85: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 85

4

PROFIBUS®-DP -eurofast® Field Wireable Connectors

eurofast® female

rating: 3 A,36 VDC

eurofast® male

rating: 3 A,36 VDC

Straight

BMSWS 8151-8.5

BMWS 8151-8.5

Right Angle

BMWS 8251-8.5

BMSWS 8251-8.5

Fem

ale

Mal

e

Accepts 4-9 mm cable.

Accepts 4-9 mm cable. Accepts 4-9 mm cable.

Accepts 4-9 mm cable.

Assembly

Page 86: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588086

PROFIBUS®-DP-Field Wireable D9 Connectors

Pinouts

1 - N/C

2 - N/C

3 - Red (Bus_B)

4 - N/C

5 - N/C

6 - N/C

7 - N/C

8 - Green (Bus_A)

9 - N/C

Right Angle Straight

Sta

ndar

dD

iag

nost

ic

PDP-Connector/D9SM

PDP-Connector/SD9SPDP-Connector/D9S

PROFIBUS®-DP – Feed Through Receptacles - type eurofast®

eurofast® feed-through receptacle,M 12 x 1• straight male/female connector• for premolded, reverse-keyed eurofast® cables

Type Applications Recommended Panel Cutout

0.63

15.9

FKW FSW 45/M12

Page 87: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 87

4

eurofast® terminating resistor(M 12 x 1)• internal resistor• female eurofast® connector• reverse-keyed

PROFIBUS®-DP Terminating Resistors

eurofast® terminating resistor(M 12 x 1)• internal resistor• male eurofast® connector• reverse-keyed

RSSW 45-TR

Type Applications Wiring diagram/pin configuration

nominal voltage: 50 VDCinternal resistance: 330 Ω, 1/4 W (2)

220 Ω, 1/4 W

RKSW 45-TR

nominal voltage: 50 VDCinternal resistance: 330 Ω, 1/4 W (2)

220 Ω, 1/4 W

PROFIBUS®-DP Active Terminating Resistors

Type Wiring diagrams

PDP-TRA

nominal voltage: 50 VDCinternal resistance: 390 Ω, 1/4 W (2)

220 Ω, 1/4 W

The active terminating resistor PDP-TRA is used to terminate a PROFIBUS®-DP segment. Due to its external power supply it ispossible to connect/disconnect any of the bus occupants without causing interferences on the bus. An LED signals the powerstatus.

eurofast® connector

1. N/C2. Bus_A3. N/C4. Bus_B5. N/C

1. N/C2. GND3. N/C4. UI = 24 VDC5. N/C

minifast® connector

Page 88: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588088

Circuit Board Connectors and OEM Receptacles

eurofast®

FKFDW 45 PCB

FSFDW 45 PCB

Panel Cut-out Board Layout (reference only**)

FKW 45 PCB KIT

FSW 45 PCB KIT

* indicates length in meters.** consult source drawing for board layout.Refer to page 78 for standard cable lengths.

FKFDW 45- *M

FSFDW 45- *M

Pinout 1. N/C2. Bus_A3. N/C4. Bus_B5. Bare

FemaleMale

WFSW 45 PCB

Page 89: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 89

4

1 Meter

TURCK Power Cordsets for PROFIBUS®-DP-minifast® Connectors and Tees

For stainless steel coupling nuts: Change part number (RSM.... to RSV....).

minifast®

RSM 50-*M WSM 50-*M RKM 50-*M WKM 50-*M

RSM RSM 50-*M RSM RKM 50-*MRSM WSM 50-*M RSM WKM 50-*M

WSM WSM 50-*M WSM WKM 50-*M

RKM RKM 50-*M RKM WKM 50-*M

WKM WKM 50-*M

Pin (Male) Socket (Female)

Soc

ket

(Fem

ale)

WSM RKM 50-*M

RSM

RKM

RSM WSM RKM

Pin

(M

ale)

min

ifast

®

WKM

WKM

WSM

Example

For stainless steel coupling nuts: Change part number (RSM 2RKM.. to RSV 2RKV..).

minifast® Power Tee

RSM 2RKM 50

Schematic Part Number Applications

WSM RKM 50-1M

Page 90: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588090

Specifications for PROFIBUS®-DP Systems

RSM 2RKM 50

WKMWSM

Pinouts

1. Black2. Blue3. Green/Yellow4. Brown5. White

Female minifast®Male minifast®

Dimensions

RKMRSM

Power Pair

NEC AWMCEC AWMFT1

DCR (/1000 ft) Insulation

6.9 ΩΩΩΩΩ PVC

Approvals AWGColor Code

5/18 AWGBk,Bu,Gn/Ye,Bn, Wh

Cable Type

50 AWM 2517

105°C 300V

Outer Jacket

PVC Yellow7.2 mm(.285 in)

Material Color Nominal O.D.

None

Shields

TypeDrain Wire

BulkCable

RF50549-*M

Page 91: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 91

4

eurofast® 5-pin Field Wireable Connectors for PROFIBUS®-DP

Male eurofast®Female eurofast®

Rating: 3 A, 36 VDC Rating: 3 A, 36 VDC

Accepts 4-8 mm cable.

Straight Right Angle

Fem

ale

Mal

e

B 8151-0 B 8251-0

BS 8151-0 BS 8251-0

Accepts 4-8 mm cable.

Accepts 4-8 mm cable.Accepts 4-8 mm cable.

Page 92: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588092

Notes

Page 93: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

4

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 93

I/O Cordsets

Page 94: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588094

TURCK Valve Connectors and eurofast® Extensions

Cable

Connector

“A” Style (18 mm)

Without LED Indicator With LED Indicator

Standard Duty PVC

Standard Duty PUR

Standard Duty PUR

Standard Duty PVC

Heavy Duty Rubber

Heavy Duty Rubber

Mal

e eu

rofa

st®

Lead

ed E

nds

Straight

Standard

Automotive

IEC

VAS 22-A653-*M-RS 5.3T

VAS 22-A669-*M-RS 5.3T

VAS 22-A654-*M-RSE 5.3T

VAS 22-B653-*M-RS 5.3T

VAS 22-B669-*M-RS 5.3T

VAS 22-B654-*M-RSE 5.3T

VAS 22-B654-*M-WSE 5.3T

VAS 22-B669-*M-WS 5.3T

VAS 22-B653-*M-WS 5.3T

VAS 22-A654-*M-WSE 5.3T

VAS 22-A669-*M-WS 5.3T

VAS 22-A653-*M-WS 5.3T

VAS 22-A653-*M VAS 22-A669-*M VAS 22-B669-*MVAS 22-B653-*M

VAS 22-A642-*M VAS 22-A587-*M VAS 22-B587-*MVAS 22-B642-*MVAS 22-A654-*M VAS 22-B654-*M

VAY 22-A658-*M VAY 22-B658-*M

Dimensions

Right

For additional options, consult TURCK Tech Support (1-800-544-7769).

* indicates length in meters.

Page 95: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

4

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 95

TURCK Valve Connectors and eurofast® Extensions

Cable

Connector

“B” Style (10 mm)

Without LED Indicator With LED Indicator

Standard Duty PVC

Standard Duty PUR

Standard Duty PUR

Standard Duty PVC

Heavy Duty Rubber

Heavy Duty Rubber

Mal

e eu

rofa

st®

Lead

ed E

nds

Straight

Standard

Automotive

IEC

VBS 2-A653-*M-RS 5.3T

VBS 2-A669-*M-RS 5.3T

VBS 2-A654-*M-RS E 5.3T

VBS 2-B653-*M-RS 5.3T

VBS 2-B669-*M-RS 5.3T

VBS 2-B654-*M-RSE 5.3T

VBS 2-B654-*M-WSE 5.3T

VBS 2-B669-*M-WS 5.3T

VBS 2-B653-*M-WS 5.3T

VBS 2-A654-*M-WSE 5.3T

VBS 2-A669-*M-WS 5.3T

VBS 2-A653-*M-WS 5.3T

VBS 2-A653-*M VBS 2-A669-*M VBS 2-B669-*MVBS 2-B653-*M

VBS 2-A642-*M VBS 2-A587-*M VBS 2-B587-*MVBS 2-B642-*MVBS 2-A654-*M VBS 2-B654-*M

VBY 2-B658-*MVBY 2-A658-*M

Dimensions

Right

For additional options, consult TURCK Tech Support (1-800-544-7769).

* indicates length in meters.

Page 96: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588096

TURCK Valve Connectors and eurofast® Extensions

Cable

Connector

“C” Style (8 mm)

Without LED Indicator With LED Indicator

Standard Duty PVC

Standard Duty PUR

Standard Duty PUR

Standard Duty PVC

Heavy Duty Rubber

Heavy Duty Rubber

Mal

e eu

rofa

st®

Lead

ed E

nds

Straight

Standard

Automotive

IEC

TC8S 2-A669-*M-RS 5.3T

TC8S 2-L669-*M-RS 5.3T

TC8S 2-L669-*M-WS 5.3T

TC8S 2-A669-*M-WS 5.3T

Dimensions

TC8S 2-A669-*M TC8S 2-L653-*M

TC8S 2-A653-*M-RS 5.3T

TC8S 2-A653-*M-WS 5.3T

TC8S 2-A653-*M

TC8S 2-A587-*MTC8S 2-A642-*M

TC8S 2-L653-*M-RS 5.3T

TC8S 2-L653-*M-WS 5.3T

TC8S 2-L669-*M

TC8S 2-L587-*MTC8S 2-L642-*M

.45.45.45.45.45

Right

For additional options, consult TURCK Tech Support (1-800-544-7769).

* indicates length in meters.

Page 97: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

4

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 97

TURCK Valve Connectors and eurofast® Extensions

Cable

Connector

“I” Style (11 mm)

Without LED Indicator With LED Indicator

Standard Duty PVC

Standard Duty PUR

Standard Duty PUR

Standard Duty PVC

Heavy Duty Rubber

Heavy Duty Rubber

Mal

e eu

rofa

st®

Lead

ed E

nds

Straight

Standard

Automotive

IEC

VIS 2-A653-*M-RS 5.3T

VIS 2-A669-*M-RS 5.3T

VIS 2-A654-*M-RSE 5.3T

VIS 2-B653-*M-RS 5.3T

VIS 2-B669-*M-RS 5.3T

VIS 2-B654-*M-RSE 5.3T

VIS 2-B654-*M-WSE 5.3T

VIS 2-B669-*M-WS 5.3T

VIS 2-B653-*M-WS 5.3T

VIS 2-A654-*M-WSE 5.3T

VIS 2-A669-*M-WS 5.3T

VIS 2-A653-*M-WS 5.3T

VIS 2-A653-*M VIS 2-A669-*M VIS 2-B653-*M VIS 2-B669-*M

VIS 2-A642-*M VIS 2-A587-*M VIS 2-A654-*M VIS 2-B642-*M VIS 2-B587-*M VIS 2-B654-*M

VIY 2-A658-*M VIY 2-B658-*M

Dimensions

Right

For additional options, consult TURCK Tech Support (1-800-544-7769).

* indicates length in meters.

Page 98: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-588098

Turck eurofast® 2-Branch Molded Splitters

• for sensors with complementary outputs, split signal.• branches have picofast®

snap lock.• combines 2 sensors into the input connector.

VBRK 4.4-2ESM 3S

VBRS 4.4-2RK 4T-*/*

• for sensors with complementary outputs, split signal.• combines 2 sensors into 1 input connector.

• combines 2 sensors into 1 input connector.• allows open circuit detection on both inputs.

VBRS 4.5-2RK 4T-*/*/S818

5

Wiring diagramApplicationsType

Turck eurofast® 2-Branch Molded Splitters

For additional options, consult TURCK Tech Support (1-800-544-7769).

* indicates length in meters.

Wiring diagramApplicationsType

YB2-FSM 4.5-2FKM 4.5

• for sensors with complementary outputs, split signal.• branches have eurofast®

connectors.• combines 2 sensors into the input connector.

3

2

5

1

4

4

1

2

3

3

5

5

4

2

1

Page 99: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

4

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 99

Dimensions

TURCK picofast® Cable and Connectors

For additional options, consult TURCK Tech Support (1-800-544-7769).

* indicates length in meters.

picofast® Pinouts

Female Male

pico

fast

®

picofast®

Page 100: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880100

TURCK eurofast® Cable and Connectors

Dimensions

For additional options, consult TURCK Tech Support (1-800-544-7769).

euro

fast

®

eurofast®

* indicates length in meters.Replace 4.4 with 4.5 and add /S653 to the end of part number for 5-pin (4-wire and connected drain) with foil shield.

TURCK eurofast® Cordset, 8-pin

For additional options, consult TURCK Tech Support (1-800-544-7769).

WK

WS

RK RS

eurofast® PinoutsFemale Male

eurofast® Pinouts

Female MaleRKC 8T-*-RSC 8T

* indicates length in meters.

Page 101: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

4

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 101

TURCK picofast® 3-pin Field Wireable ConnectorsMale picofast®Female picofast®

Accepts 3-5 mm cable.

Straight Right Angle

Fem

ale

Mal

e

B 5131-0 B 5231-0

BS 5131-0 BS 5231

Accepts 3-5 mm cable.

Rating: 3 A, 75 VDC Rating: 3 A, 75 VDC

Accepts 3-5 mm cable.

Accepts 3-5 mm cable.

Page 102: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880102

Cable Lengths and ConnectorsStandard lengths of pre-molded cordsets and bulk cable are listed below.

Cordsets Bulk Cable

meters feetmeters feet

0.3

0.5

1.0

1.5

2.0

2.5

3.0

4.0

5.0

6.0

8.0

10

15

20

25

30

40

50

1.0

1.6

3.3

4.9

6.6

8.2

9.8

13

16

20

26

33

49

66

82

98

131

164

30

75

150

225

300

- - -- - -- - -- - -- - -

Standard Cable Lengths

0-1 meter: +35 / - 0 mm> 1 m +85/-0 mm or +4% of length which ever is greater

Other lengths available upon request. Contact the factory at 1-888-546-5880. Unit Conversions:

1 meter = 3.28 feet1 meter = 39.8 inches

Tolerances:

Leaded End Color Codes and Connectors

1. N/C2. N/C3. Red 24. Red 15. Gray

1. N/C2. N/C3. Blue4. Brown5. Black

1. N/C2. N/C3. Black 24. Black 15. Gn/Yel

AutomotiveIECStandard

4

1

2

3

5

4

1

2

3

5

4

1

2

3

5

98

246

492

738

984

- - -- - -- - -- - -- - -

Page 103: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

4

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 103

P=Poor F=Fair G=Good E=Excellent

TURCK Cable Characteristics

Page 104: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

104 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Notes

Page 105: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 105

5

Installations

Page 106: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

106 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

PerformancePerformancePerformancePerformancePerformance

Flexlife cables and cordsets are designed to handle theabuse of constant motion and bending. To ensure this,FlexLife® cables undergo a series of rigorous tests to ensurelonger life in industrial settings. The tests exceed ASTM testsand MIL-specs for bend and torsional flex testing. In additionto their flexibility, they meet the signal attenuation require-ments of DeviceNet™ and PROFIBUS® networks.

The Bend Radius Test repeatedly bends the cable back and forth with a6.5 inch radius on a 180 degree plane, at a rate of 30 cycles per minute.During the test all conductors are monitored until a conductor fails. This“tick-tock” motion replicates the strenuous abuse of bending and contactwith industrial machines. Flexlife cables can withstand 10 million cycles ofthe Bend Radius Test.

The Torsional Flex Test repeatedly moves and twists the cable through 360degrees of torsional twisting. Simultaneously, it is rolling 14 inches back andforth over an eight inch diameter sheave, which remains in contact throughoutthe test. This action is continuous (30 cycles per minute) and replicates themost abusive robotic movements for an industrial cable. Again, all conductorsare monitored until a conductor fails. Flexlife cables withstand 10 million cyclesof the Torsional Flex Test.

Cable InstallationCable InstallationCable InstallationCable InstallationCable Installation

Page 107: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 107

5

Cable Bundling TCable Bundling TCable Bundling TCable Bundling TCable Bundling Techniquesechniquesechniquesechniquesechniques

CorrectCorrectCorrectCorrectCorrect IncorrectIncorrectIncorrectIncorrectIncorrect

When bundling several cables together, always keep the bundle loose enough to move within itself. Tightly tiedbundles create both compression and tension stresses when the bundle is moved.

TTTTTying Cables with Cable Tying Cables with Cable Tying Cables with Cable Tying Cables with Cable Tying Cables with Cable Tiesiesiesiesies

CorrectCorrectCorrectCorrectCorrect IncorrectIncorrectIncorrectIncorrectIncorrect

When tying cable with self locking ties, always leave the ties loose enough for the cables to slide freely under the tie.Over-tightening will create stress concentrations that can cause the conductors to fail prematurely. Never tighten thetie to the point where the cable jacket becomes deformed or pinched.

Page 108: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

108 InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880

Proper Bend Radius for Fixed and Moving ApplicationsProper Bend Radius for Fixed and Moving ApplicationsProper Bend Radius for Fixed and Moving ApplicationsProper Bend Radius for Fixed and Moving ApplicationsProper Bend Radius for Fixed and Moving Applications

Fixed ApplicationsFixed ApplicationsFixed ApplicationsFixed ApplicationsFixed ApplicationsMinimum bend radius 5 x cable diameterMinimum bend radius 5 x cable diameterMinimum bend radius 5 x cable diameterMinimum bend radius 5 x cable diameterMinimum bend radius 5 x cable diameter

Moving ApplicationsMoving ApplicationsMoving ApplicationsMoving ApplicationsMoving ApplicationsMinimum bend radius 10 x cable diameterMinimum bend radius 10 x cable diameterMinimum bend radius 10 x cable diameterMinimum bend radius 10 x cable diameterMinimum bend radius 10 x cable diameter

Proper management of cabling systems can mean the difference between a dependable and smooth operatinginstallation and costly recurring down time. The suggestions outlined below illustrate some of the common sources ofproblems and provide simple and effective solutions.

Providing sufficient bend radius will allow the cable to absorb the energy of bending over a greater portion of its length,increasing its effective working life. Small increases in the radius of the bend can produce substantial increases in cablelife.

Cable InstallationCable InstallationCable InstallationCable InstallationCable Installation

Eliminating Stress Points in Cable DressEliminating Stress Points in Cable DressEliminating Stress Points in Cable DressEliminating Stress Points in Cable DressEliminating Stress Points in Cable Dress

Strain ReliefStrain ReliefStrain ReliefStrain ReliefStrain ReliefCorrectCorrectCorrectCorrectCorrect IncorrectIncorrectIncorrectIncorrectIncorrect

Installing cables to allow for adequate stress loops and freedom of motion increases the life of the cables. InterlinkBT®

cordsets incorporate molded strain reliefs that will assist in preventing stress.

Page 109: BL67 – Table of Contents - Steven Engineeringstevenengineering.com/tech_support/PDFs/46BBL67IO.pdf · BL67 – Table of Contents BL67 – Gateways DeviceNet™ 14 PROFIBUS®-DP

InterlinkBT® 3000 Campus Drive Minneapolis, MN 55441 Phone: (01) (763) 694-2300 Fax: (01) (763) 694-2399 Toll Free: 1-888-546-5880 109

5

VVVVVisit us at wwwisit us at wwwisit us at wwwisit us at wwwisit us at www.interlinkbt.com.interlinkbt.com.interlinkbt.com.interlinkbt.com.interlinkbt.com

Check the latest articles, literature updates and product releases.Complete listing of network cables and cordsets, interconnection products, accessories,I/O stations and modules, I/O systems and more.Use keywords and phrases to locate specific information.See page link above.Check out the events in your area.Contains a complete listing of catalogs, brochures, tutorials, CAD drawings and electronicnews releases from InterlinkBT®.

Contains company information and opportunities.The login page is to access the secure area for the InterlinkBT® sales channel.

What’What’What’What’What’s New:s New:s New:s New:s New:Products:Products:Products:Products:Products:

Search:Search:Search:Search:Search:TTTTTech Support:ech Support:ech Support:ech Support:ech Support:Calendar:Calendar:Calendar:Calendar:Calendar:Literature:Literature:Literature:Literature:Literature:

Contacts:Contacts:Contacts:Contacts:Contacts:

About Us:About Us:About Us:About Us:About Us:Login:Login:Login:Login:Login:

Sales - Find reps and distributors in your area.Partners - Lists affiliates and trade associationsIntegrators - Contains integrators business summaries and web site links.Us - Submit requests and comments

Web Site Features:Web Site Features:Web Site Features:Web Site Features:Web Site Features:

Link to support.interlinkbt.comLink to support.interlinkbt.comLink to support.interlinkbt.comLink to support.interlinkbt.comLink to support.interlinkbt.com*