13
Biosensor Technologies

Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

  • Upload
    votruc

  • View
    237

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Biosensor Technologies

Page 2: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 2 Confidential

Johnson Medtech Biosensor Technology Overview

► Johnson Medtech biosensor technologies provide world-class design,

prototyping, and value added assembly for flexible circuits, printed

electronics, flat flexible cabling and microelectronics.

► Johnson Medtech has the broadest range of flexible interconnects, flex

circuits and sensor products to serve the global medical industry.

► Custom circuits are developed based on proprietary designs, processes

and materials including dielectrics, conductors, printed electronics

technology and the expert formulation of inks.

► We provide unique microelectronic design and solutions as an integral

part of our customers’ advanced system products.

Page 3: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 3 Confidential

Johnson Medtech Biosensor Products

► Applications

– ECG Sensors

– Microfluidic Sensors

► Technology Leadership

– Custom-engineered solutions

– Superior signal integrity

– Testing accuracy

– High precision

– Ease-of-use

Page 4: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 4 Confidential

Technology Print Electronic

Additive Printing

Subtractive Printing

Data Acquisition &

Accuracy

Good

(Electrochemical)

Good

(Electrochemical)

Thickness Very thin (0.4 mm) Thin (1.1 mm)

Production Process

Waste

Low (0% waste / 100%

utilized)

High (15% etched away)

Layer Configuration Single Sided, Double-

Sided, Multi-Layer

Single Sided, Double

Sided, Multi-Layer

Sensor Flexibility Curvable, Integration of

circuit & interconnects

Curved, Integration of

circuit & interconnects

Environmental

Concern

RoHS compliance RoHS compliance

Print Electronic (PE) Technology

Page 5: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 5 Confidential

Johnson Medtech ECG Disposable Sensors

► Safe Choice

– Industry leader in biosensor technology

– Testing accuracy

– Stability when exposed to human body fluid

– Over 20 years medical device experience

► Technology Leadership

– Unique AgCI conductor

– Customized conductivity

– Most conductive low impedance gel

– Superior signal integrity

– Ease-of-use

ECG Sensors ECG Sensor Applications

Page 6: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 6 Confidential

Johnson Medtech Microfluidic Sensors

► Safe Choice

– Testing accuracy

– Precise sensor printing

– Precision channel cutting

– Industry leader in biosensor technology

► Technology Leadership

– Custom-engineers solutions

– Integrated hydrophilic electrode / sensor

– Best fluid spread-ability

– Ease-of-use

Microfluidic Sensor Microfluidic Application

Page 7: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 7 Confidential

Construction of Microfluidic Sensors

(Print Electronic Technology)

Cover Layer

With circuit layout

Microfluidic Sensor

Blood

entry Enzyme or reagents Vents

Pre-cut Channels

Reaction Zone

`

Spacer Layer

Electrode Layer

Page 8: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 8 Confidential

Blood Flow in Microfluidic Sensors

► The print electronic (PE) technology allows improvements in testing accuracy, consistency and total sensor cost in four areas:-

► Electrode thickness

► Electrode surface roughness

► Electrode edge irregularity

► Electrode spacing

Electrode 1

Electrode 2

Blood flow

Channel

Page 9: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 9 Confidential

Electrode Thickness

► Reduced thickness can drive material cost saving and enable thinner microfluidic channel for lower sample volume.

Parlex

(Cross-Section View)

Others

(Cross-Section View)

Electrode (Avg. 7.0 µm*)

* Average values in 40 measurements

Electrode (Avg. 13.9 µm*)

Potting Epoxy Potting Epoxy

PET PET

Page 10: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 10 Confidential

Electrode Surface Roughness

► Reduced surface roughness leads to uniform blood flow.

Johnson Medtech Others

19.0 μm 8.0 μm

Electrode

PET

Page 11: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 11 Confidential

► Reduced edge irregularity to improve electrode spacing consistency for accurate impedance results.

Electrode Edge Irregularity

Johnson Medtech

(Top View) Others

(Top View)

40.5 μm 16.5 μm

Substrate

Electrode

Substrate

Page 12: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 12 Confidential

Electrode Spacing

► As gap between electrodes affect impedance value, this is important to maintain consistent spacing when printing is made.

Electrode Parlex Others

Spacing (mm)* 1.90 to 1.92

(1% variation)

1.94 to 2.00

(2% variation)

Electrode

Spacing

* Measurement: 10 parts / 20 data points

Electrode ink

Electrode ink

Substrate

(Top View)

Page 13: Biosensor Technologies Medtech Biosensor Technology Overview Johnson Medtech biosensor technologies provide world-class design, prototyping, and value added assembly for flexible circuits,

Page 13 Confidential

Johnson Medtech Biosensor Technology

► Technology Leadership

– Custom-engineered solutions

– Custom printed electronics

– Unique printing technology

– High precision

► Safe Choice

– Superior signal integrity

– Highly accurate testing for improved clinical outcomes

– Industry leader in biosensor technology