20
BioPlug 3.5 and 4.2 for use in reconstructive surgery ART 26 16.1 09/2015-E including DVD “Anterior Instability”

BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

Embed Size (px)

Citation preview

Page 1: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

BioPlug 3.5 and 4.2for use in reconstructive surgery

A R T 2 6 1 6 . 1 0 9 / 2 0 1 5 - E

including DVD

“Anterior Instability”

Page 2: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

2

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

BioPlug 3.5 and 4.2for use in reconstructive surgeryBioPlug 3.5 and 4.2 are resorbable suture anchors from KARL STORZ. These anchors are characterized,inparticular,bytheirmaterial,excellentfixationstrengthandtheirpulloutresistance.

BioPlug 4.2 has a drill hole of 3.7 mm, BioPlug 3.5 of 2.7 mm.

The material is an amorphous stereocopolymer poly-(L-co-D,L-lactide) 70:30, which has alreadybeenusedwithgreatsuccessintheMega Fix®-BandMega Fix®-P products. This special material, and thus the BioPlug 3.5 and 4.2, degrade (bio resorb) slowly and without any resorption reactions. It remains amorphous during the entire degradation process.

The complete instrument set for use with the BioPlug is not only reusable but has also been produced in line with the accustomed KARL STORZ high quality standards, and thus meets even the toughest demands.

TheBioPlug3.5comesinauniquepackagealreadypreloadedwiththeMegaFibre® USP 2thread.TheMegaFibre® is a non-absorbable suture composed of a unique, ultra-high-molecular-weightpolyethylenefiber.Itoffersgreatertensilestrengththanpolyesterandpolyblend sutures as well as increased lubricity and superior knot break strength.

The BioPlug 4.2 is supplied in sterile packaging and without thread.

KARL STORZ is a partner of DVSE

(German Association of Shoulder and Elbow

Surgery)

Page 3: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

3

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

Diagram of a Bankart lesion.

Tear of the middle glenohumeral ligament (MGHL) and of the anterior part of the inferior glenohumeral ligament (IGHL).

Anterior-superior, anterior-inferior portal, positioned with the SPS system.

Mobilization of the labrum-capsule complex with a sharp raspatory.

Insertion of glenoid guide and drilling of implant site with drill 28179 TB (dia. 3.7 mm) for BioPlug 4.2 and drill 28179 TD(dia.2.7mm)forBioPlug3.5.The implant site is drilled through the inferior cannula until the mark of the respective drill.

Anatomic reconstruction of the labrum-capsule complexin the case of a Bankart lesion

Page 4: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

4

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

Insertion of the BioPlug 3.5 or 4.2 suture anchor through the inferior cannula.

Removal of the inferior thread through the anterior-superior cannula.

Penetration of the labrum-capsule complex with the suture hook and guiding out of the carrier thread through the anterior-inferior cannula.

Extracorporeal knot tying with the anchor strand that has been pulled out previously.

Pulling of the thread through the labrum-capsule complex.

Page 5: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

5

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

Tying of an arthroscopic slip knot (e.g. outback).

Positioning of further BioPlug 3.5 or 4.2 anchor sutures.

Insertion of the next BioPlug anchor and penetration of the labrum capsule complex with the carrier thread (as described above)

Page 6: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

6

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

How to use the package of the preloaded BioPlug 3.5

Open the primery sterile pouch and take the package out

Hold it like it is shown in the picture. The blue triangle indicates where the BioPlug is located.

The black arrow indicates the direction for the inserter

Push the inserter (28179 TK) into the BioPlug 3.5 with the groove (retaining area for the thread) facing sideways.

Push the inserter all the way onto the BioPlug 3.5.Theanchorhastobeflushontheinserter

Page 7: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

7

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

Hold the package and just lift the inserter upwards. By tearing the paper starp on top youstarttounwindtheMegaFibre®.

SecuretheMegaFibre® thread by using the thread clips at the side of the handle.

All BioPlug anchors are resorbable push anchors. Do not twist the Inserter in order to release him. This could damage the anchor.

Pull the Inserter straight back.

Page 8: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

8

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

28229 DS High-Flow Arthroscope Sheath, with snap-in coupling mechanism, diameter 6.5 mm, working length 13.5 cm, two stopcocks, rotatable, for use with HOPKINS® Telescopes 0°, 30°, 70°andObturators28229 BC/BT

28229 BC Obturator, blunt, forusewithArthroscopeSheaths28229 DS/S,color code: green-red-yellow

28229 BT Obturator, semisharp, for use with Arthroscope Sheaths 28229 DS/S,colorcode:green-red-yellow

28140 D Gasket Attachment, withcone,includingGasket28140 GUforusewith all arthroscope sheaths

28140 GU Gasket, for single use, unsterile, single-packaged, for use with GasketAttachment28140 D

28124 BX Changing Rod, length 23 cm, for use with arthroscope sheaths with inner diameter 4 mm

28229 DS

Page 9: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

9

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

28179 TB Drill, for preparation of the tunnel for suture anchor BioPlug 2870511 BP,withlasermarkingforthedepthofthedrillhole,diameter 3.7 mm, length 15 cm

28179 TI Inserter, with lateral thread guide and thread clip at the handle, working length 18 cm, for use with BioPlug2870411 BPand2870514 BP

28179 TK Inserter, with lateral thread guide and thread clip at the handle, working length 18 cm, for use with BioPlug2870310 BP

2870411 BP* BioPlug, bioresorbable suture anchor, diameter 4.2 mm, length 11 mm, sterile, for single use, forusewithInserter28179 TI

2870310 BP*BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length10mm,withoneMegaFibre® USP 2 suture, sterile, for single use, for use with Inserter 28179 TK

* not for sale in the United States

28179 TD Drill, for preparation of the tunnel for suture anchor BioPlug 2870310 BP,withlasermarkingforthedepthofthedrillhole,diameter 2.7 mm, length 15 cm

28270 H Mallet, ergonomic handle, two plane faces, length 17 cm, color code: blue

Page 10: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

10

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

28179 KP Knot Pusher, working length 18 cm

28179 GG Glenoid Guide, working length 12.5 cm, for use with BIOPLUG 2870411 BP,2870310 BPand Drills28179 TB/TD

28179 I Crochet Hook, working length 15 cm

2870356 SC Suture Cutter, for cutting sutures size USP 2

NEW2870356 KP Knot Pusher and Suture Cutter,

for cutting sutures up to size USP 2

including: Insert and Blade Handle

Page 11: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

11

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

28179 GH HALF PIPE® long, working length 95 mm, for use with Obturator 28179 OB

28179 GK HALF PIPE® short, working length 80 mm, for use with Obturator 28179 OB

28179 OB Obturator, forusewithHALFPIPE®28179 GH/GK

28171 SGN SILGRASP® Suture Grasper, straight jaws, sheath diameter 3 mm, straight, handle with cleaning connector, working length 14 cm

28171 AGN SILGRASP® Alligator Grasping Forceps, surgical, straight jaws, sheath diameter 3 mm, straight, handle with cleaning connector, working length 12 cm

28171 AGSNSILGRASP® Alligator Grasper, surgical, with ratchet, straight jaws, sheath diameter 3 mm, straight, handle with cleaning connector, working length 12 cm

28171 PGN SILGRASP® Foreign Body Grasping Forceps, aggressive, straight jaws, sheath diameter 3 mm, straight, handle with cleaning connector, working length 14 cm

28171 PGSNSILGRASP® Foreign Body Grasper, aggressive, with ratchet, straight jaws, sheath diameter 3 mm, straight, handle with cleaning connector, working length 14 cm

Page 12: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

12

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

28179 BB Elevator, width 4 mm, 15° curved upwards, working length 15 cm

28179BC Elevator, width 4 mm, 30° curved upwards, working length 15 cm

28179CB Glenoid Rasp, width 5.5 mm, curved upwards 30°, working length15cm

28179CC S.L.A.P. Rasp, width 5.5 mm, curved upwards 30°, working length15cm

Page 13: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

13

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

28180 CB Elevator, width 4 mm, curved downwards 15°, also curved downwards in sheath, working length 15 cm, for use with cannulas inner diameter 8.25 mm

28180CC Elevator, width 4 mm, curved downwards 30°, also curved downwards in sheath, working length 15 cm, for use with cannulas inner diameter 8.25 mm

28180DC Glenoid Rasp, width 4.5 mm, curved upwards 30°, also curved upwards in sheath, working length 15 cm, for use with cannulas inner diameter 8.25 mm

28180CE S.L.A.P. Rasp, width 4.5 mm, curved downwards 30°, also curved downwards in sheath, working length 15 cm, for use with cannulas inner diameter 8.25 mm

28180CF Elevator, width 4 mm, curved downwards 15°, blade turned 180°, also curved downwards in sheath, working length 15 cm,forusewithcannulasinnerdiameter8.25mm

28180CJ Elevator, width 4 mm, curved downwards 30°, blade turned 180°, also curved downwards in sheath, working length 15 cm,forusewithcannulasinnerdiameter8.25mm

28180CL Rasp, for use as Glenoid or S.L.A.P. rasps, double-sided, width 4.5 mm, curved downwards 30°, also curved downwards in sheath, working length 15 cm, for use with cannulas inner diameter 8.25 mm

Page 14: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

14

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

Optional: The sets include Handle 28179 DH, which makes it easier to introduce Dilator 28179 DL.

Transparent plastic cannulas for single use, sterile, package of 10, are available as an alternative to

reusablecannulas.ThreadedCannulas28179SA-SDforsingleusearesuppliedunsterile.

Recommended Sets

28179FB

28179FC 28179FP

28179 EB 28179 EO

28179EC 28179 EP

28179DF

28179FO

Positioning Needle Obturator

Guide Wire

28179 DG

Dilator

28179 OG

28179 SA/SB 28179SC/SD

Page 15: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

15

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

Portal Systems for Shoulder Arthroscopy

SPS – Secure Portal System

A workable instrument set requires the following supplementary sets:

1. For inner diameter 6.1 mm, working length 7 cm 28179 EB Handle, with integrated dilator

28179 EO Obturator,diameter4mm,forusewithHandle28179 EB 28179 SA Cannula, with thread, transparent, for single use

Optional: 28179 GS Set of Gaskets, 10x 2 sealing caps, sterile, for use with

ValveHousing28179 DG/OG 28179 GU Set of Gaskets, 10x 2 sealing caps, unsterile, for use with

ValveHousing28179 DG/OG 28179 OG Valve Housing,withoutLUER-Lock,forusewithCannulasand

SetofGaskets28179 GU/GS

2. For inner diameter 6.1 mm, working length 8.5 cm 28179 EC Handle, with integrated dilator

28179 EP Obturator,diameter4mm,forusewithHandle28179EC 28179 SB Cannula, with thread, transparent, for single use

3. For inner diameter 8.25 mm, working length 7 cm 28179FB Handle, with integrated dilator 28179FO Obturator,diameter4mm,forusewithHandle28179 FB 28179SC Cannula, with thread, transparent, for single use

4. For inner diameter 8.25 mm, working length 8.5 cm 28179FC Handle, with integrated dilator 28179FP Obturator,diameter4mm,forusewithHandle28179 FC 28179 SD Cannula, with thread, transparent, for single use

28179 E Basic Set for SPS – Secure Portal System

including: Positioning Needle Obturator Guide Wire, package of 6 Dilator Handle,forDilator28179 DL Valve Housing Set of Gaskets, unsterile, package of 10

Page 16: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

16

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

Suture Instruments

28179 HG Handle, for use with monofilament threads size USP 2-0 to 2, for use with Suture Attachments 28179 PA – PH, 28728 NA – NG and Wheel Attachment 28179 HR

28179 HR Wheel Attachment, for use with monofilament threads size USP 2-0 to 2, for use with Handle 28179 HG and Wheel 28179 R

28179 R Wheel, for use with monofilament threads size USP 2-0 to 2, forusewithWheelAttachment28179 HR

28179 PA

28179 PA Suture Attachment, distal tip curved upwards, straight, 5 mm inheight,workinglength15cm,forusewithHandle28179 HG

28179 PB Suture Attachment, distal tip curved upwards, straight, 7 mm inheight,workinglength15cm,forusewithHandle28179 HG

28179PC Suture Attachment, distal tip curved upwards, straight, 8 mm in height, working length 15 cm, for use with Handle 28179 HG

28179 PD Suture Attachment, hook-shaped distal tip curved upwards, straight, 8 mm in height, working length 15 cm, for use with Handle28179 HG

28180 BG Suture Catcher, with inserter, sterile, package of 10, for use with Suture Attachments 28179 PA – PH and 28728 NA – NG, Wheel Attachment 28179 HR and Handle 28179 HG

28180 BG

Page 17: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

17

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

28179PE/PF

28179PE/PF

28179 PE Suture Attachment, hook-shaped distal tip curved upwards, straight, 8.7 mm in height, working length 15 cm, for use with Handle 28179 HG and not for use with Cannulas 28179SS/SL/BS/BL

28179 PG Suture Attachment, distal tip angled 30° to right, straight, 8 mm in height, working length 15 cm, for use with Handle 28179 HG

28179PF Suture Attachment, hook-shaped distal tip curved upwards, straight, 10 mm in height, working length 15 cm, for use with Handle 28179 HG and not for use with Cannulas 28179SS/SL/BS/BL

28179 PH Suture Attachment, distal tip angled 30° to left, straight, 8 mm inheight,workinglength15cm,forusewithHandle28179 HG

28179 R1 Cleaning Adaptor, for use with Suture Attachments 28179 PA –PHand28728 NA–NG

28179 R2 Cleaning Adaptor, forusewithHandle28179 HG

Page 18: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

18

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

Notes

Page 19: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

19

© K

AR

L S

TOR

Z 9

6152

023

AR

T 26

16.

1 09

/201

5/E

W

DVD is missing?Please call KARL STORZ for your free copy!

It is recommended to check the suitability of the product for the intended procedure prior to use.

Page 20: BioPlug 3.5 and 4 - karlstorz.com · 2870310 BP* BioPlug, bioresorbable suture anchor, diameter 3.5 mm, length 10 mm, with one MegaFibre ... for use with Obturator 28179 OB 28179

9615

2023

AR

T 26

16.

1 09

/201

5/E

W-E

KARL STORZEndoscopy-America,Inc. 2151 East Grand Avenue ElSegundo,CA90245-5017,USA Phone: +1 424 218-8100 Phone toll free: 800 421-0837 (US only) Fax: +1424218-8525 Faxtollfree: 800321-1304(USonly) E-Mail: [email protected]

KARL STORZGmbH&Co.KG Mittelstraße 8, 78532 Tuttlingen, Germany Postbox 230, 78503 Tuttlingen, Germany Phone: +49 (0)7461 708-0 Fax: +49(0)7461708-105 E-Mail: [email protected]

www.karlstorz.com