BIOCLAD® Adhesive
High strength, multi-purpose, two component polyurethane adhesive DESCRIPTION
BIOCLAD Adhesive is specifically developed as a high strength, multi-purpose, “VOC free” adhesive, suitable for bonding metals, wood and uPVC. It has been fully tested and approved for use with BIOCLAD Antimicrobial and hygienic PVC sheets. PRIMARY USES
BIOCLAD Adhesive is used as a high strength, full bed adhesive for fixing BIOCLAD PVC sheets to all suitable substrates: • Fair faced concrete • Good quality blockwork • Steel trowel finished sand cement render • Degreased, well bonded ceramic tiles • Well bonded minimum 9mm WBP resin
bonded boards • Plaster and mineral cement boards ADVANTAGES • Multipurpose adhesive, suitable for gap filling. • Ensures durable, high strength bond even in
extreme conditions. • Excellent resistance to water, solvents and
heat. • Quickly and easily mixed and applied with a
notched trowel or scraper. • VOC and odor free STANDARDS / ACCREDITATION
EU & International Accreditations, BIM / NBS Plus, CE, FDA, NHS Estates Technical Memorandum (HTM) 56, LEED and Queen's Awards for Enterprise, 2017. PACKAGING
BIOCLAD Adhesive is supplied in 6.5kg kit containing two components i.e. base (A) and curing agent (B).
TYPICAL PROPERTIES*
Base Polyurethane Color Beige Viscosity CPS Part A: thick paste
Part B: liquid Pot life 75 minutes @ 20°C
30 minutes @ 30°C Cure time 6 hours @ 20°C Temperature resistance -30°C – 120°C Application temperature 5°C – 25°C Tensile bond strength Greater than 1 N/mm²∗ Cleaner Solvent 3
∗ Tested in accordance with EN 12004. GUIDE TO APPLICATION
Application should be only performed by BASF approved applicators. Contact your local BASF representative. (Full application details are available on request.) Surface preparation: Ensure all suitable surfaces to be bonded are clean and free from grease, dust and other containments. Walls which are significantly out of plumb can be levelled using the appropriate faring mortar. Contact your BASF representative for details. Mixing: Only use full kits. Pour the contents of part B into part A and mix with a slow speed drill and paddle for at least 3 minutes. Carefully scrape down the sides of the pail with a spatula or trowel and mix for a further 2 minutes. Once mixed the adhesive must be applied and the BIOCLAD PVC Sheet affixed within its pot life. Application: Apply the mixed BIOCLAD to the substrate or to the reverse of the BIOCLAD PVC sheet with a scraper or notched trowel. Present the BIOCLAD PVC sheet to the wall and press firmly to ensure the two substrates are in contact. The adhesive will cure sufficiently to permit handling after 6 hours; However, full cure will not be achieved for 24 hours.
BIOCLAD® Adhesive
BASF_CC-UAE/Bioclad_ADH_12_17/v1/
STATEMENT OF RESPONSIBILITY
The technical information and application advice given in this BASF publication are based on the present state of our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or completeness either expressed or implied is given other than those required by law. The user is responsible for checking the suitability of products for their intended use.
NOTE Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not BASF, are responsible for carrying out procedures appropriate to a specific application.
BASF Construction Chemicals UAE LLC P.O. Box 37127, Dubai, UAE Tel: +971 4 8090800, Fax: +971 4 8851002 www.master-builders-solutions.basf.ae
Disclaimer: the LRQA mark relates to certified management system and not to the product mentioned on this datasheet
COVERAGE
BIOCLAD Adhesive is supplied in 6.5kg kit. 1 x 6.5kg kit is sufficient adhesive for 1 standard BIOCLAD sheet of 2.8m x 1.22m when applied using a 5mm x 5mm notched trowel. SHELF LIFE AND STORAGE
The product should be stored unopened in a dry condition at a temperature of 5°C – 25°C. This will ensure the stated shelf-life of 12 months. The adhesive will have limited life once the container is opened. TEMPERATURE AND TIMINGS
All information on temperature and timings represent normal working condition and is provided as a guideline only SAFETY PRECAUTIONS
As with all chemical products, care should be taken during use and storage to avoid contact with eyes, mouth, skin and foodstuffs (which could be tainted during the curing/ drying phase of the product). Treat splashes to eyes and skin immediately. If accidentally ingested, seek medical attention. Reseal the containers after use. NOTE
Field service, where provided, does not constitute supervisory responsibility. For additional information contact your local BASF representative. BASF reserves the right to have the true cause of any difficulty determined by accepted test methods.
QUALITY AND CARE
All products originating from BASF’s Dubai, UAE facility are manufactured under a management system independently certified to conform to the requirements of the quality, environmental and occupational health & safety standards ISO 9001, ISO 14001 and ISO 45001. * Properties listed are based on laboratory controlled tests. Bioclad® Registered trademark of Bioclad Ltd. UK in many countries. BASF Construction Chemicals UAE LLC is exclusive distributor of BIOCLAD Adhesive in UAE, Qatar and Bahrain. BASF Construction Chemicals L.L.C. is exclusive distributor of BIOCLAD Adhesive in the Sultanate of Oman Saudi BASF for Building Materials Co. is exclusive distributor for BIOCLAD Adhesive in the Kingdom of Saudi Arabia