16
Binks Smart Pump

Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Embed Size (px)

Citation preview

Page 1: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Binks Smart Pump

Page 2: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Smart Pump Product Line

Electric Smart Pump

• E2-20: 5 GPM (260 PSI)

• E2-30: 8 GPM (260 PSI)

• E4-60: 16 GPM (260 PSI)

• E4-90: 24 GPM (203 PSI)

Page 3: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Accessories:• Low Shear Smart BPR

¾” to 2” Connections

• Smart Card: Automatic controls for

“Smart Circ” operation

Smart Pump Product Line

Page 4: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

• Fluid Sections

• CV Drive Section

• 40:1 Gearbox

• 1.5 HP AC Motor

Description E2-20: 5 GPMDescription E2-20: 5 GPM

Page 5: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

CV Cam

Cam Follower

Swivel Joint Tension Springs

Slide Rails

Description E2-20: 5 GPMDescription E2-20: 5 GPM

Page 6: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

• AC Motor drives gear box and CV Cam.• Motor is controlled by inverter with either manual or PLC instruction.

• The motor frequency is directly proportional to the Fluid Output!

Motor Speed (HZ)

Pump CPMFluid Flow

(GPM)

20 9.8 1.23

25 12.25 1.53

30 14.7 1.84

35 17.25 2.16

40 19.8 2.48

45 22.25 2.79

50 24.7 3.09

55 27.1 3.39

60 29.5 3.69

65 31.85 3.99

70 34.2 4.28

75 36.6 4.58

80 39 4.88

Description E2-20: 5 GPMDescription E2-20: 5 GPM

Page 7: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Main Pump Assembly

Description E2-30: 8 GPM

Main Components

• 2 HP Motor & Gearbox

• Main Cam Shaft and Bearings

• 2 Cylinders 4 Ball Check

• Carriage and Cam Follower

• Carriage Support Shaft and Linear Ball Bearing Bushes

Page 8: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Description E2-30: 8 GPM

• 2 HP motor reduced through 56:1 gearbox.

• Single “constant velocity” cam & carriage assembly ensures no “hard” connections.

• (2) horizontally opposed fluid sections provide 8 GPM fluid output.

Page 9: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

E2-30 Fluid Section

• Quick disconnect fluid section.

• Internal piston/fluid seal.

• Low pressure bellows seal.

• “Run to Failure” back up seal.

Page 10: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Main Components

• 5 HP Motor & Gearbox

• Main Cam Shaft and Bearings

• 4 Cylinders 8 Ball Check

• Carriage and Cam Follower

• Carriage Support Shaft and Linear Ball Bearing Bushes

Main Pump Assembly

Description E4-60 & E4-9016 & 24 GPM

Description E4-60 & E4-9016 & 24 GPM

Page 11: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Cam area drives (4) horizontal fluid pistons therefore providing a (4) cylinder true positive displacement operating pump.

Description E4-60: 15 GPMDescription E4-60: 15 GPM

View showing Min Max Cylinder position

Page 12: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Quick Disconnect Fluid Section

QD Sanitary Clamp piston

shaft connection

“Module” Designed Fluid Section

Complete fluid section can be removed by disconnecting (4) sanitary clamps and removal of (8) bolts!

Bolted connections

Page 13: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Bellows: “Run to Failure”

Use of secondary chevron style seal behind bellows provides a back up seal and allows for visual indication of bellows failure.

• Material flow path

• Secondary Seal (vertical piston pump style seal)

• Bellows location

Provides visual indication of bellows failure and allows operator time to repair before affecting production.

Page 14: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

E4-60 Energy Consumption

Page 15: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

E2-30 Energy Consumption

Page 16: Binks Smart Pump. Smart Pump Product Line Electric Smart Pump E2-20: 5 GPM (260 PSI) E2-30: 8 GPM (260 PSI) E4-60: 16 GPM (260 PSI) E4-90: 24 GPM (203

Binks Smart Pumps

ITW Ransburg – BinksITW Group – Finishing Division

320 Phillips Ave

Toledo OH 453612