Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
163Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
FRAME
• Robust 102mm semi commercial aluminium door frame.
PANEL
• 62mm door sash stile• Durable bifold panels.• Individual panels can measure up to 2400mm high
and 900mm wide. (Note: 2700mm high in Heavy Duty panel and 1000mm wide is available)
• Sash punched holes are fitted with infill caps.*Panels configure to open out only.
SILL
• If no sill is required option is available for clear alfresco walkway.* *Nosilloptiondoesnotmeetwaterandwindrequirements.
GLAZING & ENERGY EFFICIENCY
• All Trend® Windows and Doors comply with Australian Standards AS1288.
• Glazing options from 4mm single glazed to 18mm insulated glazed units (IGUs) .
• Available in a range of glazing option.• Energy efficiency options available to help reduce
home energy consumption.• All glazing options are Window Energy Rating Scheme
(WERS) rated - providing a wide range of energy efficient solutions.
ACOUSTICS
• Acoustic solutions available for improved noise reduction.
• High Rw ratings available .
WIND & WATER RATINGS
• All Trend® Windows and Doors are designed to meet and surpass 700Pa wind velocity rating and 150Pa water penetration rating and comply with Australian Standards AS2047.
• Pascal deflection rates up to 2200Pa.• Bifold door rated at an air infiltration of 0.67L/s m2.
Bifold Door - Features & Benefits
164Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014
ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend®
Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
SECURITY
• Infinity night latch key lock hardware supplied as standard• Mortice lock mechanism pulls the door panels in tight in the
center, top and bottom locking the doors securely.
Bifold Door - Features & Benefits
BUSHFIRE
• Xtreme® Bushfire Protection option is available**.
• Xtreme® options have been tested by CSIRO to meet BAL-40 - compliant to AS1530.8.1 within Australian Standards AS3959-2009.
**Maxdoorwidthforbushfirezonesis2400mm
HARDWARE
• Infinity Satin Chrome hardware supplied as standard.• Infinity bifold lock include night latch feature - locking doors
when handle is in verticle position.• Optional colours are available:
- Pearl White- Stone Beige- Anodic Natural Matt- Gloss Black
• Door locks can be keyed alike to other Quantum® door products for ease of use.
• Hinges made out of durable stainless steel - optional black color is also available.
OPTIONS
• Glazing options also available in bar layout styles:- Colonial- Federation - Ovolo glazing bar style*
• Wide range of powder coating colours.• Customised WERS ratings.• Variety of sizes and custom made options available.• Variety of configuration options available.
*Ovoloonlyavailableinsingleglazing.
DELIVERY
• Protective wrapping for delivery to site comes standard for all Quantum® products.
165
167Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
FLASHINGBY BUILDER
HEAD
TIMBER REVEAL
HEADER
12mm CLEARANCE
NO PACKING
TIMBERARCHITRAVEBY BUILDER
OUTSIDE
10mm CLEARANCEBETWEEN SOFFIT LINING AND DOOR HEAD
QUAD BYBUILDER
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 4
0mm
FRA
ME
SIZE
FLASHINGBY BUILDER
BRICK SILLSILL TILE
FIXING BY BUILDER
65
101.6
101.6
SILL 47.7
PAC
KIN
G B
Y B
UIL
DER
FIXI
NG
S AT
450m
m C
ENTR
ES
FLA
SHIN
G B
Y B
UIL
DER
FRAME SIZE
STUD OPENING = FRAME SIZE + 60mm
STU
D
TIM
BER
REV
EAL
STU
D
BR
ICK
WO
RK
JAM
B
35.0
101.
6
SOFFIT LINING
FLOORING
MORTAR
Building In Detail | Brick Veneer - 240mm wall
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 40mmWidth = Frame Size + 60mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Sill bricks should be at least 10mm clear of door frame to allow settlement in brick veneer construction.
• Header beam should be at least 12mm clear of door frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, sill must be fully supported.
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
168Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014
ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend®
Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
FLASHINGBY BUILDER
PACKING BY BUILDER
FIXINGS AT450mm CENTRES
FLASHING BY BUILDER
FRA
ME
SIZE
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 6
0mm
STUD
HEAD
TIMBER REVEAL
STUD
TIMBER REVEAL
HEADER
12mm CLEARANCE
NO PACKING
TIMBERARCHITRAVEBY BUILDER
OUTSIDE
10mm CLEARANCEBETWEEN SOFFIT LINING AND DOOR HEAD
QUAD BYBUILDER
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 4
0mm
FRA
ME
SIZE
FLASHINGBY BUILDER
BRICK SILL
SILL TILE
MORTAR
BRICKWORK
FIXING BY BUILDER
65.0
101.6
101.6
SUMPSILL
SILL
76.8
JAMB
35
101.6
PAC
KIN
G B
Y B
UIL
DER
FIXI
NG
S AT
450m
m C
ENTR
ES
FLA
SHIN
G B
Y B
UIL
DER
FRAME SIZE
STUD OPENING = FRAME SIZE + 60mm
STU
D
TIM
BER
REV
EAL
STU
D
BR
ICK
WO
RK
JAM
B
35.0
101.
6
SOFFIT LINING
FLOORING
Building In Detail | Brick Veneer - 240mm wall | Sump Sill
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 40mmWidth = Frame Size + 60mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Sill bricks should be at least 10mm clear of door frame to allow settlement in brick veneer construction.
• Header beam should be at least 12mm clear of door frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, sill must be fully supported.
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
169Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
FLASHINGBY BUILDER
HEAD
TIMBER REVEAL
HEADER
12mm CLEARANCE
NO PACKING
TIMBERARCHITRAVEBY BUILDER
OUTSIDE
10mm CLEARANCEBETWEEN SOFFIT LINING AND DOOR HEAD
QUAD BYBUILDER
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 4
0mm
FRA
ME
SIZE
FLASHINGBY BUILDER
BRICK SILL
SILL TILEMORTAR
FIXING BY BUILDER
65.0
101.6
101.6
SILL
47.7
PAC
KIN
G B
Y B
UIL
DER
FIXI
NG
S AT
450m
m C
ENTR
ES
FLA
SHIN
G B
Y B
UIL
DER
FRAME SIZE
STUD OPENING = FRAME SIZE + 60mm
STU
D
TIM
BER
REV
EAL
STU
D
BR
ICK
WO
RK
JAM
B
35.0
101.
6
SOFFIT LINING
FLOORING
Building In Detail | Brick Veneer - 240mm wall | Rebated
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 40mmWidth = Frame Size + 60mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Sill bricks should be at least 10mm clear of door frame to allow settlement in brick veneer construction.
• Header beam should be at least 12mm clear of door frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, sill must be fully supported.
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
170Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014
ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend®
Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
FLASHINGBY BUILDER
HEAD
TIMBER REVEAL
HEADER
12mm CLEARANCE
NO PACKING
TIMBERARCHITRAVEBY BUILDER
OUTSIDE
10mm CLEARANCEBETWEEN SOFFIT LINING AND DOOR HEAD
QUAD BYBUILDER
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 4
0mm
FRA
ME
SIZE
FLASHINGBY BUILDER
BRICK SILL
SILL TILEMORTAR
FIXING BY BUILDER
65.0
101.6
101.6
SILL
SUMPSILL
76.8
PAC
KIN
G B
Y B
UIL
DER
FIXI
NG
S AT
450m
m C
ENTR
ES
FLA
SHIN
G B
Y B
UIL
DER
FRAME SIZE
STUD OPENING = FRAME SIZE + 60mm
STU
D
TIM
BER
REV
EAL
STU
D
BR
ICK
WO
RK
JAM
B
35.0
101.
6
SOFFIT LINING
FLOORING
Building In Detail | Brick Veneer - 240mm wall | Rebated | Sump Sill
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 40mmWidth = Frame Size + 60mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Sill bricks should be at least 10mm clear of door frame to allow settlement in brick veneer construction.
• Header beam should be at least 12mm clear of door frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, sill must be fully supported.
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
171Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
FLASHINGBY BUILDER
HEAD
TIMBER REVEAL
HEADER
12mm CLEARANCE
NO PACKING
TIMBERARCHITRAVEBY BUILDER
OUTSIDE
10mm CLEARANCEBETWEEN SOFFIT LINING AND DOOR HEAD
QUAD BYBUILDER
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 4
0mm
FRA
ME
SIZE
FLASHINGBY BUILDER
BRICK SILL
SILL TILE
MORTAR
FIXING BY BUILDER
65
101.6
101.6
SILL 47.7
PAC
KIN
G B
Y B
UIL
DER
FIXI
NG
S AT
450m
m C
ENTR
ES
FLA
SHIN
G B
Y B
UIL
DER
FRAME SIZE
STUD OPENING = FRAME SIZE + 60mm
STU
D
TIM
BER
REV
EAL
STU
D
BR
ICK
WO
RK
JAM
B
35
101.
6
SOFFIT LINING
FLOORING
TIMBERJOIST
SILLSUPPORT
Building In Detail | Brick Veneer - 240mm wall | Joists
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 40mmWidth = Frame Size + 60mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Sill bricks should be at least 10mm clear of door frame to allow settlement in brick veneer construction.
• Header beam should be at least 12mm clear of door frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of door, install sill support (refer to drawings below).
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
172Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014
ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend®
Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
FLASHINGBY BUILDER
HEAD
TIMBER REVEAL
HEADER
12mm CLEARANCE
NO PACKING
TIMBERARCHITRAVEBY BUILDER
OUTSIDE
10mm CLEARANCEBETWEEN SOFFIT LINING AND DOOR HEAD
QUAD BYBUILDER
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 4
0mm
FRA
ME
SIZE
FLASHINGBY BUILDER
BRICK SILL
SILL TILE
MORTAR
FIXING BY BUILDER
65.0
101.6
101.6
SILL
76.8
PAC
KIN
G B
Y B
UIL
DER
FIXI
NG
S AT
450m
m C
ENTR
ES
FLA
SHIN
G B
Y B
UIL
DER
FRAME SIZE
STUD OPENING = FRAME SIZE + 60mm
STU
D
TIM
BER
REV
EAL
STU
D
BR
ICK
WO
RK
JAM
B
35.0
101.
6
SOFFIT LINING
FLOORING
TIMBERJOIST
SILLSUPPORT
SUMPSILL
Building In Detail | Brick Veneer - 240mm wall | Joists | Sump Sill
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 40mmWidth = Frame Size + 60mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Sill bricks should be at least 10mm clear of door frame to allow settlement in brick veneer construction.
• Header beam should be at least 12mm clear of door frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of door, install sill support (refer to drawings below).
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
173Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
OUTSIDE
FRA
ME
SIZE
BR
ICK
OPE
NIN
G =
FR
AM
E SI
ZE +
3m
m
FLASHING BY BUILDER
BRICKWORK BRICKWORK
CAVITY FIXING BLOCK
CEMENT RENDER
STEEL LINTEL BY BUILDER
SILL TILE
MORTAR
FLASHING BY BUILDER
BRICK SILL
65.0HEAD
101.6
FIXING BY BUILDER
47.7
101.6
SILL
FRAME SIZE
BRICK OPENING = FRAME SIZE + 3mm
JAM
B
FLA
SHIN
GB
Y B
UIL
DER
CEMENT RENDERB
RIC
KW
OR
K
BU
ILD
ING
IN L
UG
S AT
450m
m C
ENTR
ESB
RIC
KW
OR
K
101.
6
35.0
FLOORING
Building In Detail | Double Brick - 280mm wall
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 3mmWidth = Frame Size + 3mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Header beam should be at least 12mm clear of window frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, sill must be fully supported.
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
174Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014
ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend®
Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
OUTSIDE
FRA
ME
SIZE
BR
ICK
OPE
NIN
G =
FR
AM
E SI
ZE +
3m
m
FLASHING BY BUILDER
BRICKWORK BRICKWORK
CAVITY FIXING BLOCK
CEMENT RENDER
STEEL LINTEL BY BUILDER
SILL TILE
MORTAR
FLASHING BY BUILDER
BRICK SILL
65.0
HEAD
101.6
FIXING BY BUILDER
76.8
101.6
SILL
SUMPSILL
FRAME SIZE
BRICK OPENING SIZE = FRAME SIZE + 3mm
JAM
B
FLA
SHIN
GB
Y B
UIL
DER
CEMENT RENDER
BR
ICK
WO
RK
BU
ILD
ING
IN L
UG
S AT
450m
m C
ENTR
ESB
RIC
KW
OR
K
101.
6
35.0
FLOORING
Building In Detail | Double Brick - 280mm wall | Sump Sill
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 3mmWidth = Frame Size + 3mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Header beam should be at least 12mm clear of window frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, sill must be fully supported.
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
175Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
OUTSIDE
FRA
ME
SIZE
BR
ICK
OPE
NIN
G =
FR
AM
E SI
ZE +
3m
m
FLASHING BY BUILDER
BRICKWORK BRICKWORK
CAVITY FIXING BLOCK
CEMENT RENDER
STEEL LINTEL BY BUILDER
SILL TILE
MORTAR
FLASHING BY BUILDER
BRICK SILL
65.0
HEAD
101.6
FIXING BY BUILDER
47.7
101.6
SILL
FLOORING
FRAME SIZE
BRICK OPENING = FRAME SIZE + 3mm
JAM
B
FLA
SHIN
GB
Y B
UIL
DER
CEMENT RENDER
BR
ICK
WO
RK
BR
ICK
WO
RK
101.
6
35.0
BU
ILD
ING
IN L
UG
S
FIXI
NG
AT
450m
m C
ENTR
ES
Building In Detail | Double Brick - 280mm wall | Prepared Opening
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Brick Opening:Height = Frame Size + 3mmWidth = Frame Size + 3mm
• Secure aluminum doors using building lug into mortor - fixing at 450mm max centres
• Sill bricks should be at least10 mm clear of window frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, sill must be fully supported.
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
176Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014
ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend®
Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
OUTSIDE
101.6
101.6
61.7
SUBSILL
FLOORING
SILL
BLOCKWORK(SEALED OR PRETREATED BY BUILDER
AS PER BLOCKWORK SUPPLIER’S SPECIFICTION - TO PREVENT WATER PENETRATION)
FIXING 450 CENTRES
PACKER
FIXING 450 CENTRES
FIXING 450 CENTRES
SEALANT
FRA
ME
SIZE
BLO
CK
WO
RK
OPE
NIN
G =
FR
AM
E H
EIG
HT
+ 40
mm
PACKER
SEALANT
35.0
101.
6
JAM
B
BLO
CK
WO
RK
(SEA
LED
OR
PR
ETR
EATE
D B
Y B
UIL
DER
AS
PER
BLO
CK
WO
RK
SU
PPLI
ER’S
SPE
CIF
ICTI
ON
- TO
PR
EVEN
T W
ATER
PEN
ETR
ATIO
N)
FRAME SIZE
BLOCKWORK OPENING = FRAME SIZE + 20mm
FIXI
NG
450
CEN
TRES
AN
GLE
TR
IM B
Y B
UIL
DER
FIXI
NG
450
CEN
TRES
REN
DER
BY
BU
ILD
ER
REN
DER
BY
BU
ILD
ER
HEAD
65.0
Building In Detail | Blockwork
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Blockwork Opening:Height = Frame Height + 40mmWidth = Frame Size + 20mm
• Fit subframe to opening and seal fixings.• Fit window to subframe (screw or pop-rivet).• Do not permit weight of eaves or arch bars to bear
on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, sill must be fully supported.
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
177Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
OUTSIDE
NO PACKING
TIMBER REVEAL
HEADER
TIMBER ARCHITRAVE BY BUILDER
12mm CLEARANCE
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 4
0mm
FRA
ME
SIZE
DRESS SARKING INTO CLADDING "U" TRIM AT HEAD AS SHOWN
FIXING BY BUILDER
WALL CLADDING
FLASHING BY BUILDER
TRIM BY BUILDER
ALUMINIUM OR VINYLWALL CLADDING
FLASHING BY BUILDER
65.0HEAD
101.6
101.6
47.7SILL
CA
ULK
ING
FRAME SIZE
STUD OPENING = FRAME SIZE + 60mm
FIXI
NG
S AT
450
mm
CEN
TRES
PAC
KIN
G B
Y B
UIL
DER
STU
D
TIM
BER
REV
EAL
STU
D
FLA
SHIN
G
BY
BU
ILD
ER
WALL CLADDING
35.0
101.
6
JAM
B
FLOORING
Building In Detail | Cladding on Studwall
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 40mmWidth = Frame Size + 60mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Header beam should be at least 12mm clear of window frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, install sill support (refer to drawings below).
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
178Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014
ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend®
Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
OUTSIDE
NO PACKING
TIMBER REVEAL
HEADER
TIMBER ARCHITRAVE BY BUILDER
12mm CLEARANCE
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 4
0mm
FRA
ME
SIZE
DRESS SARKING INTO CLADDING "U" TRIM AT HEAD AS SHOWN
FIXING BY BUILDER
WALL CLADDING
FLASHING BY BUILDER
TRIM BY BUILDER
ALUMINIUM OR VINYLWALL CLADDING
FLASHING BY BUILDER
65.0HEAD
101.6
101.6
76.8
SILL
SUMPSILL
FLOORING
CA
ULK
ING
FRAME SIZE
STUD OPENING = FRAME SIZE + 60mm
FIXI
NG
S AT
450
mm
CEN
TRES
PAC
KIN
G B
Y B
UIL
DER
STU
D
TIM
BER
REV
EAL
STU
D
FLA
SHIN
G
BY
BU
ILD
ER
WALL CLADDING
35.0
101.
6
JAM
B
Building In Detail | Cladding on Studwall | Sump Sill
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 40mmWidth = Frame Size + 60mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Header beam should be at least 12mm clear of window frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors install sill support (refer to drawings below).
• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
179Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
RENDERBY BUILDER
FLASHINGBY BUILDER
RENDERBY BUILDER
FLOORING
HEBEL POWER PANEL
SILL
FRA
ME
SIZE
OUTSIDE
NO PACKING12mm CLEARANCE
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 4
0mm
10mm CLEARANCEBETWEEN SOFFIT LINING AND WINDOW HEAD
QUAD BYBUILDER
SOFFIT LINING
TIMBER ARCHITRAVEBY BUILDER
TIMBER REVEAL
FLASHINGBY BUILDER
HEADER
101.6
101.6
47.7
HEAD
HEB
EL P
OW
ER P
AN
EL
FLA
SHIN
G B
Y B
UIL
DER
STU
D
STU
D
FRAME SIZE
STUD OPENING = FRAME SIZE + 60mm
PAC
KIN
GB
Y B
UIL
DER
FIXI
NG
S AT
450m
m C
ENTR
ES
TIM
BER
REV
EAL
JAM
B
35.0
65.0
FIXINGS AT450mm CENTRES
Building In Detail | Hebel Power Panel
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 40mmWidth = Frame Size + 60mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Header beam should be at least 12mm clear of window frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, sill must be fully supported.
• Caulking between render and frame• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
180Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014
ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend®
Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
RENDERBY BUILDER
RENDERBY BUILDER
FLOORING
HEBEL POWER PANEL
SILL
SUMPSILL
FRA
ME
SIZE
OUTSIDE
NO PACKING12mm CLEARANCE
STU
D O
PEN
ING
= F
RA
ME
SIZE
+ 4
0mm
10mm CLEARANCEBETWEEN SOFFIT LINING AND WINDOW HEAD
QUAD BYBUILDER
SOFFIT LINING
TIMBERARCHITRAVEBY BUILDER
TIMBER REVEAL
FLASHINGBY BUILDER
HEADER
101.6
76.8
HEAD
HEB
EL P
OW
ER P
AN
EL
FLA
SHIN
G B
Y B
UIL
DER
STU
D
STU
D
FRAME SIZE
STUD OPENING = FRAME SIZE + 60mm
PAC
KIN
GB
Y B
UIL
DER
FIXI
NG
S AT
450m
m C
ENTR
ES
TIM
BER
REV
EAL
JAM
B
35.0
65.0
FLASHINGBY BUILDER
FIXINGS AT450mm CENTRES
Building In Detail | Hebel Power Panel | Sump Sill
Bifold Door - Installation
INSTALLING FRAME CORRECTLY
• Fit flashing to door surround (refer to drawing below).
• Measure the frame opening to ensure that there is sufficient room for the product and additional packing.
Stud Opening:Height = Frame Size + 40mmWidth = Frame Size + 60mm
• Secure aluminum door by nailing through reveal into studwork - fixing at 450mm maximum centres.
• Header beam should be at least 12mm clear of window frame.
• Do not permit weight of eaves or arch bars to bear on any window or door frame. (Windows and doors are not load bearing.)
• To ensure the satisfactory long term performance of doors, sill must be fully supported.
• Caulking between render and frame• Build-in 3mm camber to head.• Bifolds top-hung - beam must support weight.• Ensure outside finish does not block sill drainage
holes.
181
182
Quantum® Bifold Door
Cross Sectional Views
Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend®
Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
183Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
Two Panel
73.0 73.027.4 27.4
35.037.0
125.816.0
16.0
100.
030
.0
60.0
65.090.0
47.788.9
13.5
48.0
101.6
32.5
25.0
outside outside
Bifold Door - Cross Sectional Views
184Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014
ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend®
Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
Two Panel | Thermashield
73.0 73.027.4 27.4
35.0125.8
35.016.0
16.0
100.
030
.0
60.0
18.0
65.090.0
47.788.9
48.0
101.6
32.5
26.5
outside outside
Bifold Door - Cross Sectional Views
185Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend® Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
Two Panel | Heavy Duty | Elevation
73.027.4
115.
030
.0
65.0105.0
88.947.7
48.0
101.6
42.5
outside
Bifold Door - Cross Sectional Views
186Trend® Windows & Doors | Design Manual | Q-Mk-1 | May 2014
ConfidentialityNotice:ThisdocumentandtheinformationitcontainsarecopyrightandconfidentialtoTrend® Windows&DoorsPtyLimited.Disclosure,useandcopyinginanyformwhatsoever,exceptasauthorisedbyTrend®
Windows&Doorsinwriting,arestrictlyprohibited.PatentsandDesignRegistrationspending
Please note that drawings displayed are not to scale
73.0
35.0
27.4
35.0
125.816.0
16.085
.0
outside
Two Panel | Heavy Duty | Plan
Bifold Door - Cross Sectional Views