DRAWINGS (ELECTRICAL & CIVIL) Volume-4 of 4 Planning, Designing, Supply, Manufacturing, Testing, Erection and Commissioning and trial run for 3 months of Electrical works with complete Automation , Civil and structural works for 6 nos. 12.5 MVA, 33/11 KV, Indoor Sub-stations including civil works i.e Sub-Station Building, foundation of various equipment, campus development with boundary wall, Gates, Roads, Drainage, Fire Protection Works, Campus light etc. and one no. office building having an overall covered area of about 100 sqmtrs. at one of the Sub-station Sites at IMT Faridabad MARCH 2013

BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

Embed Size (px)

Citation preview

Page 1: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

DRAWINGS

(ELECTRICAL & CIVIL)

Volume-4 of 4 Planning, Designing, Supply, Manufacturing, Testing, Erection and Commissioning and trial run for 3 months of Electrical works with complete Automation , Civil and structural works for 6 nos. 12.5 MVA, 33/11 KV, Indoor Sub-stations including civil works i.e Sub-Station Building, foundation of various equipment, campus development with boundary wall, Gates, Roads, Drainage, Fire Protection Works, Campus light etc. and one no. office building having an overall covered area of about 100 sqmtrs. at one of the Sub-station Sites at IMT Faridabad

MARCH 2013

Page 2: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

BATTER

Y RO

OM

CO

NTR

OL R

OO

M

3500 X

3500

3500 X

3500

TO

ILET

BATH

33/1

1 kv

10/1

2.5

M

VA

TRF.-2

33/1

1 kv

10/1

2.5

M

VA

TRF.-1

L.V. SIDE

L.V. SIDE

H.V. SIDE

S.T

RF

11/.4

33KV

415V ACDB

2500

33 KV I/C-1

33 KV O/G-1

TRF-1

BUS

BUS PT-2

TRF-2

33 KV O/G-2

33KV I/C-2

SPACE

COUPLER

SPACE

BUS PT-1

H.V. SIDE

CHARGER/DCDB

1500

3500

40000

800

800

1300

1300

1300

1300

1300

1300

1300

1300

1300

1300

1300

345

3000345

RS

5 MTR. wide Road

10402301635

1990

2000

7500

7500

Burn

tO

ilTank

1500

2500

19200

RS3000

D

D

1635

1493

1635

1493

D2D2

2, D

=1000X2100

2, D

2=750X

1750

19, W

=1500X1500

3, G

=5000m

m W

ide

2, R

S=

3000m

m W

ide

1635 345

230

Boundary

Wall =

1.5

mtr. h

ightW

ith M

.S.

Hooks &

Barb

ed w

ire. 0

.60 m

ts. lenght fixed

on Y S

hap

ed a

ngle

s.

WW

WW

WW

W

W

WW

WW

WW

WW

W

GG

23, C

olu

mn=

345X450

G

2, V

=300X300

V V

345

2000

13000

I/C-1

I/C-2

BPT-2

BPT-1

B/C

CF-2

CF-1

O/G-7

O/G-8

O/G-9

O/G-10

O/G-11

SPACE

SPACE

O/G-5

O/G-4

O/G-3

O/G-2

O/G-1

O/G-12

SPACE

SPACE

S.TRF.

O/G-6

1250X1200

mm

BU

RIE

D

AR

R. for 3

3KV

H.T

.Cable

2000

700

850

5000

5000

WW

11 K

V P

AN

EL

345

3500

3850

9039

5000

5000

3000

3000

2000

1000

1000

1200230

4500

4500

1000 4500 1000 1339

9039

5000

1000

1000 13001 1500 230

30000

3580

2000

1000

5000

1800

3200

1200

567

3200

233

230

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

800

1500

1820

27850

230

345

1000345

12311345

1500230

30000

230

Typ

ical Indoo

r Type

33/1

1KV S

ub S

tationLayo

ut Pla

n

For IMT Farid

abad

N

Draw

ing no.:S

S-1

1000

6500

1166

11 P,S

ector 30, G

urgaon- 122001 P

h: 0124-4034715 FA

X: 4034714

Legen

d

4.8

MVAR

CAP.B

AN

K-1

4.8

MVAR

CAP.B

AN

K-2

1000

1000

Fire W

all

61393000

1500

1500

2000800

Cam

pus Lig

ht 1

50

W H

PSV(1

2 N

os )

Roa

d C

rossing

Thro

ugh

NP-4

Rcc Pip

e

Roa

d C

rossing

Throu

gh R

CC

NP-4

Paved Area

Road C

rossin

g T

hrou

gh

300 sq

m. N

P-2

Rcc Pip

e/ C

ulv

ert

Road C

rossin

g T

hrou

gh

NP-4

Rcc P

ipe/cu

lvert

Tre

nch

cove

red w

ith

chequre

d p

late

Tre

nch

cove

red w

ith

chequre

d p

late

Tre

nch

cove

red w

ith

chequre

d p

lateTre

nch

cove

red w

ith

PCC sla

bes

Tre

nch

cove

red w

ith

PCC sla

bes

850

1250

SECTION-B-B

SEC

TIO

N-B

-B

SEC

TIO

N-A

-A

SEC

TIO

N-A

-A

850X1200 m

m B

URIE

D A

RR.

FOR

33 K

V H

.T. C

ABLE

S

1000X1000

mm

RC

C C

able

Tre

nch

for 1

1 K

VH

.T. ca

ble

700X1000m

m C

able

Tre

nch

forL.T

./Contro

l Cable

coverd

with

RCC

slabs

Page 3: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

33K

V O

/G L

INE-

1 TO

OTH

ER

33/1

1KV

SU

BST

ATI

ON

FO

R

RIN

G M

AIN

SY

STEM

33K

V I/

C L

INE-

2 FR

OM

22

0/33

KV

HV

PN

SUB

.STA

TIO

N

1C-6

30 S

QM

M-A

L-X

LPE

CABL

E

36 K

V 6

30A

VC

BO

UTG

OIN

G-1

36 K

V 6

30A

VC

BIN

CO

MER

-2

BUS

SEC

TIO

N

630

A V

CB

600

-300

/5 A

15V

A,

5P1

036

KV

400

AV

CB

TR

F.-1

36 K

V 4

00A

VC

B T

RF.

-2

400-200/5/5 A

12K

V 4

00A

VC

B C

.F.-1

12 K

V 8

00A

VC

B

INC

OM

ER.-1

400A

400A

400A

400A

400A

400A

400A

400A

400A

800/

5A15

VA

5P1

0

0-80

0/5

A

600

-300

/5 A

15V

A,

0.5

400-200/5/5 A

400-200/5/5 A 400-200/5/5 A

12 K

V 8

00A

VC

B

INC

OM

ER.-2

300-150-75/5/5A

0-75

/300

300-150/5/5A

60-30/5/5A

800/5/5A 800/5/5A

11 P

,Sec

tor 3

0,

Gur

gaon

- 122

001

P

h: 0

124-

4034

715

FAX

:

40

3471

4

Dra

win

g N

o.

SLD

-1

800/5/5A 800/5/5A

800A

BU

S-C

OU

PLER

33K

V I/

C L

INE-

1 FR

OM

22

0/33

KV

HV

PN

SUB

.STA

TIO

N

36 K

V 6

30A

VC

BIN

CO

MER

-136

KV

630

A V

CB

OU

TGO

ING

-2

33K

V O

/G L

INE-

2 TO

OTH

ER

33/1

1KV

SU

BST

ATI

ON

FO

R

RIN

G M

AIN

SY

STEM

POW

ER T

RF.

-1

33/1

1 K

V 1

2.5

MV

A

,DY

n11,

ON

AN

TY

PE

POW

ER T

RF.

-233

/11

KV

12.

5 M

VA

,D

Yn1

1, O

NA

N T

YPE

YY

600-300/5/5 A

33K

V /

√3 3P

H P

T 0.

11KV

/ √

3 0.

11KV

3

SUR

GE

D

IVER

IER

50 V

A /

50 V

A / 3

P

2A M

CB

2A M

CB

FUSE3A

P2

51

51N

67

67

N

27

59

TO

SC

AD

A

TTB

MFM

K

WH

ASS

A V

VSS

P1

DIR

. 0 /

C&

E / F

PR

OTE

CTI

ON

TO S

CADA

CO

RE-

115

VA

/ 5P

10

CO

RE-

20.

5

94

74

86

52X

33K

V

MA

IN B

US,

630A

,

50H

Z.

26.3

KA

FO

R 3

SEC.

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

11K

V

MA

IN B

US,

10

00A

,

50H

Z.

18.4

KA

FO

R 1

SEC.

IDM

T O

VER

CUR

RENT

51N

51

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

94

74

86

52X

1C-6

30 S

QM

M-A

L-X

LPE

CABL

E

600-300/5/5 A

33K

V /

√3 3P

H P

T 0.

11KV

/ √

3 0.

11KV

3

SUR

GE

D

IVER

IER

50 V

A /

50 V

A / 3

P 2A M

CB

2A M

CB

FUSE3A

P2

51

51N

67

67

N

27

59

TO

SC

AD

A

TTB

MFM

K

WH

ASS

A V

VSS

P1

DIR

. 0 /

C&

E / F

PR

OTE

CTI

ON

TO S

CADA

CO

RE-

115

VA

/ 5P

10

CO

RE-

20.

5

1C-6

30 S

QM

M-A

L-X

LPE

CABL

E

600-300/5/5 A

33K

V /

√3 3P

H P

T 0.

11KV

/ √

3 0.

11KV

3

SUR

GE

D

IVER

IER

50 V

A /

50 V

A / 3

P

2A M

CB

2A M

CB

FUSE3A

P2

51

51N

67

67

N

27

59

TO

SC

AD

A

TTB

MFM

K

WH

ASS

A V

VSS

P1

DIR

. 0 /

C&

E / F

PR

OTE

CTI

ON

TO S

CADA

CO

RE-

115

VA

/ 5P

10

CO

RE-

20.

5

1C-6

30 S

QM

M-A

L-X

LPE

CABL

E

600-300/5/5 A

33K

V /

√3 3P

H P

T 0.

11KV

/ √

3 0.

11KV

3

SUR

GE

D

IVER

IER

50 V

A /

50 V

A / 3

P

2A M

CB

2A M

CB

FUSE3A

P2

51

51N

67

67

N

27

59

TO

SC

AD

A

TTB

MFM

K

WH

ASS

A V

VSS

P1

DIR

. 0 /

C&

E / F

PR

OTE

CTI

ON

TO S

CADA

CO

RE-

115

VA

/ 5P

10

CO

RE-

20.

5

IDM

T O

VER

CU

RR

ENT

ASS A

51

3A

33K

V /

√3

TO M

FM

0.11

KV /

√3

0.11

KV

√3

50V

A

0.5/

3P

2A M

CB

3PH

BU

S P

T2 50V

A 3P

SP

ARE

RV

SSV

272

59

1-10

Sec

104-

110%

40-8

0%

3A

33K

V /

√3

TO M

FM

0.11

KV /

√3

0.11

KV

√3

50V

A

0.5/

3P

2A M

CB

3PH

BU

S P

T1 50V

A 3P

SP

ARE

RV

SSV

272

59

1-10

Sec

104-

110%

40-8

0%

CO

RE-

1C

LASS

5P1

0

CO

RE-

2C

LASS

5P1

0

CO

RE-

1C

LASS

0.5

CO

RE-

2

5P

10

A

MFM

A

SS

51

TO

SC

AD

A

50

SPA

RE

P1 P2 P1 P2

FRO

M B

US

PT

87

SUR

GE

D

IVER

TER

1C-3

00 S

q.m

m-A

L-X

LPE

1Cor

e 10

00 S

q.m

m-A

L-X

LPE

SUR

GE

D

IVER

TER

CO

RE-

1C

LASS

0.5

CO

RE-

2

5P

10

P1

P2 P1

BC

T-2

800/

5 A

20V

A5P

10

BC

T-1

800/

5 A

V(R

)L

e<30

mA

at V

51N

TTB

MFM

K

WH

ASS

A

VSS

V

59

27/2

0-15

KV

51N

51

CO

RE-

1C

LASS

PS

CO

RE-

2C

LASS

5P1

0

64R

11K

V /

√3

50V

A/0

.5

50V

A/3

P

0.11

KV

√3

0.11

KV /

√3

FUSH

3A

FUSH

4A

PT

P2

11

KV

SW

ITC

HG

EAR

TTB

M

FM

KW

H

ASS

VSS

V

59

27/2 51

N

51

A

FR

OM

B

US

PT

CO

RE-

115

VA

CL.

1

CO

RE-

215

VA

5P 1

0

P2P1

1-3C-300 Sq mm-AL-XLPE

Station Transformer

TTB

MFM

K

WH

ASS

A

VSS

V

59

27

51N

51

37

46SU

RG

E

DIV

ERTE

R

0-80

0 /5

A

CO

RE-

1C

LASS

0.5

CO

RE-

2

5P

10

P2 P1

FRO

M

NCT

3Cx

300

Sq.

mm

-AL-

XLP

E

11K

V /

√3

50V

A/0

.5

50V

A/3

P

0.11

KV

√3

0.11

KV /

√3

FUSH

3A

FUSH

4A

PT

4.8

MV

AR

CA

PS. B

AN

K

11K

V C

APA

CIT

OR

BAN

K -

1

N

CT-1

10

/1+1

15V

A,

CL

0.5

15V

A,

5P10

TTB

M

FM

KW

H

ASS

51N

51

A

FR

OM

B

US

PT

CO

RE-

115

VA

CL.

1

CO

RE-

215

VA

5P 1

0

P1 P2

1-3C-300 Sq mm-AL-XLPE

OUT GOING FEEDER 1

300-150/5/5A

TTB

M

FM

KW

H

ASS

51N

51

A

FR

OM

B

US

PT

CO

RE-

115

VA

CL.

1

CO

RE-

215

VA

5P 1

0

P1 P2

1-3C-300 Sq mm-AL-XLPE

OUT GOING FEEDER 2

300-150/5/5A

TTB

M

FM

KW

H

ASS

51N

51

A

FR

OM

B

US

PT

CO

RE-

115

VA

CL.

1

CO

RE-

215

VA

5P 1

0

P1 P2

1-3C-300 Sq mm-AL-XLPE

OUT GOING FEEDER 3

300-150/5/5A

TTB

M

FM

KW

H

ASS

51N

51

A

FR

OM

B

US

PT

CO

RE-

115

VA

CL.

1

CO

RE-

215

VA

5P 1

0

P1 P2

1-3C-300 Sq mm-AL-XLPE

OUT GOING FEEDER 4

300-150/5/5A

TTB

M

FM

KW

H

ASS

51N

51

A

FR

OM

B

US

PT

CO

RE-

115

VA

CL.

1

CO

RE-

215

VA

5P 1

0

P1 P2

1-3C-300 Sq mm-AL-XLPE

OUT GOING FEEDER 5

300-150/5/5A

TTB

M

FM

KW

H

ASS

51N

51

A

FR

OM

B

US

PT

CO

RE-

115

VA

CL.

1

CO

RE-

215

VA

5P 1

0

P1 P2

1-3C-300 Sq mm-AL-XLPE

OUT GOING FEEDER 6

300-150/5/5A

TTB

M

FM

KW

H

ASS

51N

51

A

FR

OM

B

US

PT

CO

RE-

115

VA

CL.

1

CO

RE-

215

VA

5P 1

0

P1 P2

1-3C-300 Sq mm-AL-XLPE

OUT GOING FEEDER 7

300-150/5/5A

TTB

M

FM

KW

H

ASS

51N

51

A

FR

OM

B

US

PT

CO

RE-

115

VA

CL.

1

CO

RE-

215

VA

5P 1

0

P1 P2

1-3C-300 Sq mm-AL-XLPE

OUT GOING FEEDER 8

12K

V 4

00A

VC

B C

.F.-1

300-150-75/5/5A

0-75

/300

94

74

86

52X

TTB

MFM

K

WH

ASS

A

VSS

V

59

27

51N

51

37

46SU

RG

E

DIV

ERTE

R

CO

RE-

1C

LASS

0.5

CO

RE-

2

5P

10

P2 P1

FRO

M

NCT

11K

V /

√3

50V

A/0

.5

50V

A/3

P

0.11

KV

√3

0.11

KV /

√3

FUSH

3A

FUSH

4A

PT

4.8

MV

AR

CA

PS. B

AN

K

11K

V C

APA

CIT

OR

BAN

K -

2

11K

V /

√3

50V

A/0

.5

50V

A/3

P

0.11

KV

√3

0.11

KV /

√3

FUSH

3A

FUSH

4A

PT

CO

RE-

2C

LASS

5P

10

CO

RE-

1C

LASS

0.5

CO

RE-

1C

LASS

PS

CO

RE-

25P

10

TTB

MFM

K

WH

ASS

A

51N

51

64R

SUR

GE

D

IVER

TER

TO

SC

AD

A

MFM

A

SS

A

VV

SS

59

27/2

0-15

KV

51N

P1 P2

CO

RE-

2C

LASS

5P

10

CO

RE-

1C

LASS

0.5

CO

RE-

25P

10

P2

CO

RE-

1C

LASS

5P

10

P1

SUR

GE

D

IVER

IER

50 51

SPA

RE

P2 P1

P1

P2

87

BC

T-2

800/

5 A

20V

A5P

10

BC

T-1

800/

5 A

V(R

)Le

<30m

Aat

V

FRO

M B

US

PT

Y Y Y

Y Y

Y

Y Y Y

Y Y Y

LEG

END

SYM

BO

LD

ESC

RIP

TIO

NSY

MB

OL

DES

CR

IPTI

ON

M

SUR

GE

D

IVER

IER

MO

TOR

ISED

ISOL

ATOR

WIT

H E

/S

BU

SHIN

G C

.T.

CU

RR

ENT

TRA

NSFO

RMER

11K

V V

AC

UU

M C

KT.

BR

K.

DR

AW

OU

T TY

PE

CB

CT-

CO

RE

BALA

NCE

CU

RR

ENT

TRA

NSF

ORM

ER

MU

LTI

FUN

CTI

ON

MET

ER

CB

CT-

CO

RE

BALA

NCE

CU

RR

ENT

TRA

NSF

ORM

ER

(IC

T)

TEST

TER

MIN

AL

BLOC

K

KIL

O W

ATT

HO

UR

MET

ER

VO

LT M

ETER

SEL

ECTO

R SW

ITCH

AM

ETER

SEL

ECTO

R SW

ITCH

TIM

ER R

ELAY

CIR

CU

IT B

REAK

ER

IDM

T O

VER

CU

RR

ENT

RELA

Y

DIR

ECTI

ON

EA

RTH

FA

ULT

REL

AY

OV

ER V

OLT

EGE

PRO

TEC

TION

REL

AY

NEG

ATI

VE

PHA

SE S

EQU

ENC

E PR

OCTI

ON

RES

TRIC

TED

E/F

REL

AY

DEF

FER

ENTI

AL

PR

OTE

CTI

ON R

ELAY

BR

K. A

UX

. C

ON

TAC

T M

ULTI

PLIE

R

EAR

TH P

RO

TEC

TIO

N W

ITH

INVE

RSE

DEF

INIT

E M

INIM

UM

TIM

E

UN

DER

VO

LTA

GE

REL

AY

VO

LTM

ETER

AM

ETER

AN

TI P

UM

PIN

G N

REL

AY

TRIP

CIR

CU

IT S

UPE

RVI

SION

REL

AY

TRIP

ING

REL

AY

DIR

ECTI

ON

AL

OV

ER C

UR

REN

T R

ELAY

INST

AN

TAN

EOU

S, T

IME

DELE

Y O

VER

CU

RR

ENT

RELA

Y

UN

DER

CU

RR

ENT

REL

AY

MFM

TTB

KW

H

VSS

ASS 2 52 51 67

N

59

46 64R 87 94 74 86 52X

51N 27 V A 67 50 51 37

Sin

gle

Line

Dia

gram

for T

ypic

al In

door

Typ

e 33

/11K

VS

ub S

tatio

n (

IMT

Farid

abad

)

Page 4: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

1250

d 75

875

2d

2d

2d

2d

75

75

Cable R

oute Marker

H.T. C

able

Ram

med Fill Excauted soil

(after removing bigger

stones or pieces of rock)

PCC

PREC

AST SLA

B75 m

m TH

K./class A

Brick

150

TYPIC

AL 33kV

H.T. C

AB

LE BU

RIED

AR

RA

NG

EMEN

T FOR

IMT (Faridabad)

Quarry D

ust/Sand

11 P,Sector 30,

Gurgaon- 122001

Ph: 0124-4034715 FAX

: 4034714

Note:-

1- Burial D

epth of cable =1025mm

2- "d" is overall diameter of cable.

3- Bending radiuos not less than 8 d.

Generally shall be m

aintained at 15 d.4- PC

C slab shall be laid over the sand cushion

flat along the entire length.5- cables are to be laid as per TechnicalSpecification.6- R

elevent clauses of IS are to be followed.

7- All diem

ensions are in mm

.

DRW

.No.

SS-3

1200

75

2d

75

Section- A-A

Page 5: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

850

d 75

875

2d

2d

2d

75

75

Cable R

oute Marker

H.T. C

able

Ram

med Fill Excauted soil

(after removing bigger

stones or pieces of rock)

PCC

PREC

AST SLA

B75 m

m TH

K./class A

Brick

150

Quarry D

ust/Sand

11 P,Sector 30,

Gurgaon- 122001

Ph: 0124-4034715 FAX

: 4034714

Note:-

1- Burial D

epth of cable =1025mm

2- "d" is overall diameter of cable.

3- Bending radiuos not less than 8 d.

Generally shall be m

aintained at 15 d.4- PC

C slab shall be laid over the sand cushion

flat along the entire length.5- cables are to be laid as per TechnicalSpecification.6- R

elevent clauses of IS are to be followed.

7- All diem

ensions are in mm

.

DRW

.No.

SS-3A

1200

75

75

Section- B-B

TYPIC

AL 33kV

H.T. C

AB

LE BU

RIED

AR

RA

NG

EMEN

T FOR

IMT (Faridabad)

Page 6: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

TYPIC

AL 11kV

H.T. C

AB

LEU

ND

ERG

RO

UN

D C

AB

LE TREN

CH

FOR

IMT (Faridabad)

11 P,Sector 30,

Gurgaon- 122001

Ph: 0124-4034715 FAX

: 4034714

Note:-

1- Distance betw

een M.S. C

hannel Supportsshould not be m

ore than 1 mtr.

2- Slabs shall be laid over the Trenchalong the entire length.4- cables are to be laid as per TechnicalSpecification.5- R

elevent clauses of IS are to be followed.

6- All diem

ensions are in mm

.

DRW

.No.

SS-4

1000

1000 115

300

250

250

300

115 thick RC

C slab

75 mm

thick RC

C Trench w

all

ISMC

100 x 50 x 6mm

,800mm

longM

.S.Channel Support fixed in

RC

C Trench W

all

ISA 50 x 6 m

m 300m

m long A

ngle welded

with M

.S. Channel Support

78 197250

347228

75800

Page 7: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

TYPIC

AL L.T./C

ON

TRO

L CA

BLE

TREN

CH

FOR

IMT (Faridabad)

11 P,Sector 30,

Gurgaon- 122001

Ph: 0124-4034715 FAX

: 4034714

Note:-

1- Distance betw

een M.S. C

hannel Supportsshould not be m

ore than 1 mtr.

2- Slabs shall be laid over the Trenchalong the entire length.4- cables are to be laid as per TechnicalSpecification.5- R

elevent clauses of IS are to be followed.

6- All diem

ensions are in mm

.

DRW

.No.

SS-5

700

1000 115

250

250

250

115 thick RC

C slab

75 mm

thick RC

C Trench w

all

ISMC

100 x 50 x 6mm

,800mm

longM

.S.Channel Support fixed in

RC

C Trench W

all

ISA 50 x 6 m

m 300m

m long A

ngle welded

with M

.S. Channel Support

78197

250

347228

75800

Page 8: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

D

D

D2

D

D2DD

D

Verandah

2500 mm

wide

Toilet 2270 X 1440

Verandah

2500 mm

wide

D2

Staff R

oom4000 X5040

Toilet1290X2500

R/R

2480X2500W WV

W

WW W

Room

3790 X 3370

Staff Room

3790 X 4270D

OO

R / W

IND

OW

SC

HE

DU

LED

= 1000 X 2100

D2 = 750 X 2100

W = 1200 X

1200V

= 600 X 450

73103

Area=100 Sqm

.

Plan

SU

N S

HA

DE

SU

N S

HA

DE

SU

N S

HA

DE

SUN SHADE SUN SHADE SUN SHADE

SUN SHADE SUN SHADE

Projection

Office B

uilding 33kvS

ubstation IMT Faridabad

DW

Notes:-

1. All D

imensions in M

illimeters

2. Dim

ensions shall not be measured

3. Any draw

ing error or divergences be brought to the N

otice

Plinth Projection

Page 9: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

G.L.

P.L.

Rcc P

arapet Wall

200mm

Thick RC

C

40mm

thick Kotah S

tone Flooring

100mm

thick sand filling

100mm

Thick RC

C

100mm

Thick RC

C

D2

40mm

thick slab CC

1:2:4

DD

W

Office B

uilding 33kvS

ubstation IMT Faridabad

Detail of S

un Shade

DP

C &

Plinth Beam

DP

C &

Plinth Beam

DP

C &

Plinth Beam

Foundationas per design

Page 10: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

G.L.

P.L.

Rcc P

arapet Wall

LVL.+0.00

100mm

Thick RC

C

D

Office B

uilding 33kvS

ubstation IMT Faridabad

Notes:-

1. All D

imensions in M

illimeters

2. Dim

ensions shall not be measured

3. Any draw

ing error or divergences be brought to the N

otice

RE

AR

ELE

VA

TION

Parapet W

all

G.L.

P.L.

LVL.+0.00

Page 11: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

FOUNDATION PLAN FOR 12.5MVA TRANSPORMER

℄ of Rail

AA A

Detail -C

Detail-D

Detail -1Insert Plate1000' c/c

P1P1

P1 P1

JP JP

JP JP

BB

HV S

IDE

LV S

IDE

SWR PIPE SLEEVE

100 OPNING

CC

100 OPNING

GRAVELFILLING

SECTION A-ATRANSFORMER FOUNDATION

12 Ø T 120 C/CTOP/BOTH WAYS

12 Ø T 200 C/C

12 Ø 200 C/C

100 TH. PCC ( 1:4:8 )

8 Ø T 150 C/CTOP/BOTH WAYS

T1ES8 T 175 C/C

Q

8 Ø T 200 C/C

PLINTH LEVELLEVEL

ADJUSTING NUT

20 Ø FOUNDATION

MAIN NUT

LDCK NUT

3 THICK VASHER

STRUCTURE BASE PLATE

FOOTING DETAIL OF FOUNDATIONBOLT FOR CABLE SUPPORT STRUCTURE

Q

Q

100 TH. PCC ( 1:4:8 )Q

Q

33kv Substation IMT Faridabad

Page 12: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

AAA

CAP

ACITO

R BA

NK

FOU

ND

ATIO

N PLAN

Threaded Portion

Structure B

ase Plate

Plinth Level

10 T Ø200 c/c

Both W

aysTop &

Bottom

Q

SEC

TION

A-A

33kv Substation

IMT Faridabad

Page 13: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

5 M. W

IDE

RO

AD

Expansion Joint 25 m

m w

ideE

xpansion Joint 25 mm

Thick

Contraction Joint 20 m

m w

ide

33kv Substation IM

T Faridabad

Page 14: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

200 mm

Thick Cem

ent Concrete (1:1.5:3 ) M

-40

1:50 Cam

ber1:50 C

amber

TYP

ICA

L DE

TAIL O

F CO

NC

RE

TE R

OA

D

33kv SubstationIM

T Faridabad

Notes:-

1. All D

imensions in M

illimeters

Kurb

Kurb

Page 15: BhallajidELECTRICALIMT Faridabad-33 kV Sub-station …hsiidc.etenders.in/tnduploads/hsiidc/tndheader/TND000097000000000... · 33kv o/g line-1 to other 33/11kv substation for ring

Master D

isplayU

nit

A4 Laser P

rinterN

etwork P

rinterA

4 Laser Printer

Netw

ork Printer

Antenne

P1

P2 S

ync Unit

GP

STim

eM

DU

Ant. 0/P

P1

P2

P1

P2

M-H

MI

R-H

MI

Station Level E

thernet Sw

itch-1S

tation Level Ethernet S

witch-2

SU

BS

TATIO

N-1

SU

BS

TATIO

N-2

SU

BS

TATIO

N-4

SU

BS

TATIO

N-5

SU

BS

TATIO

N-6

SU

BS

TATIO

N-3

Bay Level E

thernet Sw

itch

BC

U

ED

-1

ED

-2

M-G

ATE

WA

Y

BC

U

ED

-1

ED

-2

M-G

ATE

WA

Y

BC

U

ED

-1

ED

-2

M-G

ATE

WA

Y

BC

U

ED

-1

ED

-2

M-G

ATE

WA

Y

BC

U

ED

-1

ED

-2

M-G

ATE

WA

Y

BC

U

ED

-1

ED

-2

M-G

ATE

WA

Y

Bay Level E

thenet Sw

itchB

ay Level Ethernet S

witch

Bay Level E

thernet Sw

itchB

ay Level Ethernet S

witch

Bay Level E

thernet Sw

itch

NO

TE:-$$$ H

MI S

HA

LL BE

PLA

CE

D IN

SU

BS

TAIO

N-6

AR

MO

UR

ED

FO C

AB

LE S

HA

LL BE

LAY

ED

BE

TWE

EN

SU

BS

TAIO

NS