better analysis counts
Application Areas: • Totalsulfuranalysisfromultralowsulfur
fuelstocrudes.
• Totalchlorineanalysisfromaqueous solutionsandaromaticproductstoheavy fuels,crudes,andcatalyst.
• Foruseinrefinerylabs,pipelineterminals, additiveplantsandinspectionlaboratories.
• ComplieswithASTMD2622,D7039, D7536,andSH/T0842.
Features and Benefits:• Sulfur
- LOD:0.4ppmat300s.- DynamicRange:0.4ppmto5%
• Chlorine- LOD:0.3ppmat300s.- DynamicRange:0.3ppmto3000ppm
• Extremelylowmaintenance:noconversiongasses,heatingelements,columns,orquartztubing.
• Automaticsulfurcorrectionforchlorine.
• Easytouse- Intuitivetouchscreen- Justplug-inandmeasure- Measurementtime:30-900s
• Fitsonanybench:37cm(w)x50cm(d)x34cm(h).
Options:• LIMSdataoutputsoftwarecapability.
TWO critical measurements, ONE push of a button, ZERO hassleSindie+Clisatwo-in-oneinstrumentenablingtraceanalysisofbothsulfur
andchlorinewithonepushofabutton.Itistheidealsolutiontocertifysulfur
levelsinfinishedproducts,assesschlorineforcorrosionmitigation,and
optimizeprocessparameters.
better analysis counts15 Tech Valley Drive • East Greenbush, New York 12061, USA • 518.880.1500 • Fax: 518.880.1510 e-mail: [email protected] • website: www.xos.com
© XOS
POLYCHROMATICX-RAYS FROM TUBE
MONOCHROMATICEXCITATION
X-RAYSFROM SAMPLE
SULFURBEAM
CHLORINEBEAM
SAMPLE
OPTIC 1 OPTICS 2 & 3
Cl S
Cl DETECTO
R
S DETECTO
RTUBE
Trusted Precision Using the industry’s most advanced optics, doubly curved crystals, Sindie +Cl achieves a high signal-to-background ratio for the most reproducible results.
MonochromaticWavelengthDispersiveX-RayFlourescence(MWDXRF)usingdoubly
curvedcrystalopticshastheadvantageofveryhighsensitivityandprecision.This
techniquehasbeensuccessfullyusedtodeliververyprecisemeasurementsoflow
levelsofsulfurandchlorine.
Test Method ASTM D7039, D2622, D7536, and SH / T 0842
Dimensions 37 cm (w) x 50 cm (d) x 34 cm (h)
Power 100-120 VAC, 47-63 HZ at 6.0 Amps/200-240 VAC, 47-63 HZ at 6.0 Amps
Sample Cup Volume 10 ml
I/O Ports Ethernet 10/100 base T, RS232
Ambient Temperature Requirements 5-40o C (40-104o F)
Dynamic Range Sulfur: 0.4 ppm - 5% Chlorine: 0.3 ppm - 3000 ppm
Measurement User selectable: 30-900 s
Calibration 8 calibration curves. Automatic and Manual Calibration functionality
Product Specifications
Zero Hassle
Sindie+Clanalyzesabroadrangeofliquidsamplesfromaqueoussolutionstotheheaviestofhydrocarbons(e.g.VGOorcrudeoil),allwithouttheneedfordilution,combustiongasses,orotherhassleslikechangingdetectors,boats,injectors,furnaces,etc.
1 2
3 4
Two Critical Measurements
Sindie+Clperformstraceanalysisofbothsulfurandchlorinewithonepushofabutton.Youcanmeasurebothelementsinonesample,ormeasureeachseparatelybysimplyinsertinganewsample.