27

beko part2

Embed Size (px)

DESCRIPTION

beko part2

Citation preview

Page 1: beko part2

LG Air Conditioners 2011

Page 2: beko part2

If you need a highly efficient airconditioning system in your building, VRS is the right choice for you.

Low Static

High Static

Ceiling & Floor

Ceiling Suspended

Floor Standing- With Case

Floor Standing- Without Case

Wall Mounted

4Way Casstte

2Way Casstte

1Way Casstte

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 3: beko part2
Page 4: beko part2

Super l ight BLDC motor guarantees your enhanced comfortable indoor environment.

Vane angle control satisfies both users who like direct wind and indirect wind. and also it prevents cold air draft.

Low Noise

4 Vanes Independent Operation

Easy filter cleaning with elevation grille

Auto Elevation Grille

Typing Office Conversation Library 4 way CST

Direct air flow Indirect air flow

Individual vane operation

Individual vane angle control

All vane operation

Air flow rate control

- Installed inside main body- Auto horizontal level- 4 points support- Memory for user’s level- Max. 4.5m length

New Cassette4.5m

Conventional3.5m

4-Point support structure Auto horizontal control

STOP

Memory

Memory for user’s level Auto bottom detection

Max

.4.5

m

*Available for 24k ~ 48k Btu/h

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 5: beko part2

Wide Jet Vane

High Ceiling Mode

Improved wide and narrow vane will provide comfortabletemperature distribution without air flow dead zone.

High ceiling mode with phase-control algorithm is possible toapply as high as 3.6m of ceiling.

80mm Wider!! 567mm

487mm

NEW

Current

Even air distribution27°C

Temp.

15°C

Highlander

Air flow dead zone27°C

Temp.

15°C

Current

• Air flow improvement

4 way CSTConventional

Page 6: beko part2

Flexible connection of remote controller

- Group control : 1 remote controller to several indoor units

- Second remote control : 2 remote controllers to 1 indoor unit

Flexible Connection

It is possible to make each rooms cool & warm withinstalling a chamber and a spiral duct.

Application of Ceiling Concealed Duct

Max. 9 discharging

• Easy & solid attachment to the wall

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 7: beko part2

Linear E.S.P ControlAir volume and sound are always kept as design regardless ofE.S.P change using this technology , you can

• Optimize duct work Installation• Keep capacity & sound level as desired• Simplify model numbers

The phase control motor technology offers money savingbenefit to the installer.

The indoor unit with slim and compact size has reduced therestriction which enables successful installation in variousspaces.

Compact Size

*E.S.P is easily controlled by remote controller

LG conventional

204mm

218mm

246mm

288mm

6.0 ~ 7.2 kW 8.3 ~ 11.0 kW

Page 8: beko part2

It provides easy installation with a one-touch detachable panel.

Easy installation with corner detachable decoration panel.

One Touch Type Panel

Convenient Installation

• Coner detachable design

Drain leakage check

Refrigerantpiping check

Hanger adjust Hanger adjust

Drain leakage check Hanger adjust

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 9: beko part2

Easy Drain InstallationIt reduces the installation time by over 40% with elbow-lessdrain hose.

Midget drain pump covers maximum 800mm high, featuringeasy piping installation.

* Accessory (Drain hose) PHDHA05T – 500mm 30EA

PHDHA07T - 700mm 30EAPHDHA05B – 500mm 5EAPHDHA07B – 700mm 5EA

Drain hose Drain pump

3Way Flexible InstallationAll sides (front, back, floor) are possible to install and connectto the outdoor unit.

Back

Side Floor

Sliding Type FilterAll sides (front, back, floor) are possible to install and connectto the outdoor unit.

Sliding type

Anti-biotic filter Easy cleaning

Page 10: beko part2

Unique NEO Plasma air purifying system is equipped with 7 specialized filters in 5 separate stages toenhance its cleaning power. It reduces fine dust and mold, unpleasant odors and cigarette smoke as airpasses through each filter.

Neo Plasma Air Purifying System

Clean AirPolluted Air

Odor Free! Dust Free! Allergy Free!

Pre Filter

The antibacterial pre-filter primarily reduces large dust, mold and

quilt dust.

01

Triple Filter

The triple filter consists of three specialized filters to reduce the

symptoms associated with various organic compounds

including formaldehyde. It also has the ability to reduce

unpleasant odors creating a more comfortable environment.

02

Bio Fusion Filter

Bio fusion filters allow their Bio enzymes to directly penetrate

through cell walls of some bacteria and allergen to decompose

its cell nuclei.

03

Plasma Filter

The PLASMA Air Purifying System developed uniquely and

not only reduces microscopic contaminants and dust, but also

reduces house mites, pollen, and pet fur to reduce allergy and

asthma symptoms.

04

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 11: beko part2

Digital Air Flow ControlThe air flow can be controlled to ensure maximum comfortand convenience.

Swirl SwingSwirl swing distributes air evenly throughout the room toensure a more comfortable conditioned environment byadjusting the movement of the vane.

Healthy DehumidificationDehumidification mode reduces uncomfortable humidity fromthe room without over cooling.

Normalfast & even widely

Jet coolspeedy & powerful

Sleep modeindirectly & softly

Swirl swing(plaesant air)

Normal air flow Vertical Temp.differences

Horizontal Temp.differences

• Comparison of temperatures

Healthy

By increasing the vane angle,a better approach of the actualtemperature is possible to pre-vent over cooling.

ConventionalSince the surrounding tempera-ture is measured after the airfrom the unit is widely distrib-uted, accurate approach of theair is not possible.

Indoor Temperature Distribution Chart

Page 12: beko part2

Different air flow of cooling & heating For cooling, the vane is adjusted upwards to let the cold air travel up. As for heating, the vane sends the heated air downwards to balance room temperature specially for floor.

1st Advanced pre filter :The antibacterial pre-filter primarily reduces large dust, mould and quilt dust.

2nd Allergy Filter : Filter consists of enzyme that breaks down allergen, apatite, andorganic/inorganic binder that attaches the enzyme to the filter. When the air passes the filter, allergen clings to the filter and like tiny pairs of scissors the enzymes cut allergen's protein to deactivate the allergen.

3rd Plazma Inon Generator : The sterilized ion generating system, Ion Generator, emits around 1.2 million ions, and catches hazardous substances floating in the air, therefore proactively looking for and catching germs.

Comfort Air Flow

Healthy Air (3 stage air filter system)

Cooling Heating (Nomal)

Heating(Floor Heating Mode)

3rd Plazma Inon Generator

1st Advanced pre filter

2nd Allergy Filter

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 13: beko part2

Auto CleanAuto clean helps to remove odor and save clean-up time.After using airconditioner, “Auto clean” makes the inner part ofAir conditioner dry for 30 min. It removes mositure and moldso you can enjoy odor-free air and save time to clean up.

Auto Clean Conventional

Dries the evaporator with gentlelow noise air from the fan byremoving any remaining moisture.Pressing the Auto Clean button will acti-vate the automatic cleaning function afterthe cooling operation.

1 STEP

Removes moulds through theneo plasma system.Only the fan will operate to dry the inner partof the air conditioner in just 30 minutes.

2 STEP

ow controlAdjust the horizontal airflow direction by manually movingthe horizontal airflow direction vane by hand.

owThe airflow direction can be adjusted as desired by usingthe remote controller.

Air Flow Direction Control

latnoziroH•airflow control

lacitreV•airflow control

Page 14: beko part2

The operator can set an on/of f reservation of the airconditioner for a period of one week.

LCD Wired Remote Controller

• On/Off• Test run mode• Self-diagnosis• 3-step fan speed selection• Operation indication• Room temperature

Wired Remote Controller

Wireless remote controller

Weekly Program

Accessory

SUNDAY

MONDAY

TUESDAY

WEDNESDAY

THURSDAY

FRIDAY

SATURDAY

PQWRH(C)DF0-X

Deluxe Type

PQRCUDS0-XStandard Type

PQRCVSL0-X Standard Type

PQRCVSL0QW-XSimple Type

PQRCVCL0QW-XPQRCVCL0Q-X

Simple Type for Hotel

PQRCHCA0QW-XPQRCHCA0Q-X

Standard Type

PZRCUSB0-X

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 15: beko part2

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions(WxDxH) mm

Weight kg

Noise level dBA±3

Air flow rate H/M/L CMM

Neo Plasma air purifying filter

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI07GGSEP-X

2.2

7,500

2.5

8,500

40

40

1, 220~240, 50

895x165x282

9

37 / 33 / 23

5.6 / 5 / 4.6

Ø6.35(1/4)

Ø12.7(1/2)

20/16

BTNI12GGSEP-X

3.6

12,300

4.0

13,600

40

40

1, 220~240, 50

895x165x282

9

41 / 36 / 27

9.5 / 9 / 8.5

Ø6.35(1/4)

Ø12.7(1/2)

20/16

BTNI09GGSEP-X

2.8

9,600

3.2

10,900

40

40

1, 220~240, 50

895x165x282

9

39 / 35 / 25

7 / 6.5 / 6

Ø6.35(1/4)

Ø12.7(1/2)

20/16

BTNI15GGSEP-X

4.5

15,400

5.0

17,100

40

40

1, 220~240, 50

895x165x282

9

42 / 36 / 27

10.5 / 9 / 8.5

Ø6.35(1/4)

Ø12.7(1/2)

20/16

BTNI18GS5P-X

5.6

19,100

6.3

21,500

40

40

1, 220~240, 50

1090x178x300

12

44 / 40 / 36

12 / 10.5 / 9

Ø6.35(1/4)

Ø12.7(1/2)

20/16

BTNI24GS5P-X

7.1

24,200

8.0

27,300

40

40

1, 220~240, 50

1090x178x300

12

46 / 41 / 38

14 / 13 / 10

Ø9.52(3/8)

Ø15.88(5/8)

20/16

Note :1. Capacities are based on the following conditions

Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WBOutdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WBInterconnecting piping length 7.5mLevel difference of zero

Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WBOutdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5mLevel difference of zero

2. Due to our policy of innovation some specifications may be changed without notification

WALL MOUNTEDBTNI07GGSEP-X

BTNI09GGSEP-X

BTNI12GGSEP-X

BTNI15GGSEP-X

BTNI18GS5P-X

BTNI24GS5P-X

* AccessoriesModel

Dry Contact PQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI07GGSEP-X BTNI12GGSEP-XBTNI09GGSEP-X BTNI15GGSEP-X BTNI18GS5P-X BTNI24GS5P-X

Page 16: beko part2

BTNI05GTRP-X

BTNI07GTRP-X

BTNI09GTRP-X

BTNI12GTRP-X

BTNI15GTQC-X

BTNI18GTQC-X

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions Body mm

(WxDxH) Front panel mm

Weight Body kg

Front panel

Panel Color

Noise level dBA±3

Air flow rate H/M/L CMM

Neo Plasma air purifying filter

Drain Pump

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI05GTRP-X

1.6

5,500

1.8

6,100

30

30

1, 220~240, 50

570x570x214

700x700x30

13.1

3.2

Morning Fog

29 / 27 / 26

7.5 / 7 / 6.6

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI09GTRP-X

2.8

9,600

3.2

10,900

30

30

1, 220~240, 50

570x570x214

700x700x30

14.2

3.2

Morning Fog

30 / 29 / 27

8 / 7.5 / 7.1

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI18GTQC-X

5.6

19,100

6.3

21,500

30

30

1, 220~240, 50

570x570x256

700x700x30

15.5

3.2

Morning Fog

37 / 35 / 34

11.2 / 11 / 10

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI07GTRP-X

2.2

7,500

2.5

8,500

30

30

1, 220~240, 50

570x570x214

700x700x30

13.1

3.2

Morning Fog

29 / 27 / 26

7.5 / 7 / 6.6

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI15GTQC-X

4.5

15,400

5.0

17,100

30

30

1, 220~240, 50

570x570x256

700x700x30

15.5

3.2

Morning Fog

36 / 34 / 32

11 / 10 / 9.3

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI12GTRP-X

3.6

12,300

4.0

13,600

30

30

1, 220~240, 50

570x570x214

700x700x30

14.2

3.2

Morning Fog

32 / 30 / 27

8.7 / 8 / 7

Ø6.35(1/4)

Ø12.7(1/2)

32/25

Note :1. Capacities are based on the following conditions

Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WBOutdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WBInterconnecting piping length 7.5mLevel difference of zero

Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WBOutdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5mLevel difference of zero

2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact

Front Panel

PQDSA

PQDSB/ PQDSB1

PQDSBC

PT-UQC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI05GTRP-X BTNI09GTRP-X BTNI18GTQC-XBTNI07GTRP-X BTNI15GTQC-XBTNI12GTRP-X

4 WAY CASSETTE (570*570)

Page 17: beko part2

BTNI24GTPP-X

BTNI28GTPP-X

BTNI36GTNP-X

BTNI42GTMP-X

BTNI48GTMP-X

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions Body mm

(WxDxH) Front panel mm

Weight Body kg

Front panel

Panel Color

Noise level dBA±3

Air flow rate H/M/L CMM

Neo Plasma air purifying filter

Drain Pump

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI24GTPP-X

7.1

24,200

8.0

27,300

33

33

1, 220~240, 50

840x840x204

950x950x25

20.8

5.6

Morning Fog

36 / 34 / 31

17 / 15 / 13

Ø9.52(3/8)

Ø15.88(5/8)

32/25

BTNI36GTNP-X

10.6

36,200

11.9

40,600

144

144

1, 220~240, 50

840x840x246

950x950x25

23.5

5.6

Morning Fog

43 / 40 / 37

25 / 21 / 19

Ø9.52(3/8)

Ø15.88(5/8)

32/25

BTNI28GTPP-X

8.2

28,000

9.2

31,500

33

33

1, 220~240, 50

840x840x204

950x950x25

20.8

5.6

Morning Fog

39 / 35 / 33

19 / 16 / 14

Ø9.52(3/8)

Ø15.88(5/8)

32/25

BTNI48GTMP-X

14.1

48,100

15.9

51,200

144

144

1, 220~240, 50

840x840x288

950x950x25

25.6

5.6

Morning Fog

46 / 43 / 41

31 / 29 / 27

Ø9.52(3/8)

Ø15.88(5/8)

32/25

BTNI42GTMP-X

12.3

42,000

13.8

43,800

144

144

1, 220~240, 50

840x840x288

950x950x25

25.6

5.6

Morning Fog

44 / 41 / 38

30 / 27 / 24

Ø9.52(3/8)

Ø15.88(5/8)

32/25

Note :1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact

Front Panel

Auto Elevation Grille

Ventilation Kit

PQDSA

PQDSB/ PQDSB1

PQDSBC

PT-UMC

PTEGM0

PTVK410 / PTVK420 / PTVK 430

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI24GTPP-X BTNI28GTPP-X BTNI36GTNP-X BTNI42GTMP-X BTNI48GTMP-X

4 WAY CASSETTE (840*840) Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 18: beko part2

BTNI18GTLP-X

BTNI24GTLP-X

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions Body mm

(WxDxH) Front panel mm

Weight Body kg

Front panel

Panel Color

Noise level dBA±3

Air flow rate H/M/L CMM

Neo Plasma air purifying filter

Drain Pump

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI18GTLP-X BTNI24GTLP-X

5.6

19,100

6.3

21,500

70

70

1, 220~240, 50

830x550x225

1,050x640x28.5

22

4.5

Morning Fog

40 / 36 / 32

13 / 12 / 10

Ø6.35(1/4)

Ø12.7(1/2)

32/25

7.1

24,200

8.0

27,300

70

70

1, 220~240, 50

830x550x225

1,050x640x28.5

22

4.5

Morning Fog

42 / 38 / 34

17 / 15 / 13

Ø9.52(3/8)

Ø15.88(5/8)

32/25

Note :1. Capacities are based on the following conditions

Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WBOutdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WBInterconnecting piping length 7.5mLevel difference of zero

Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WBOutdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5mLevel difference of zero

2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact

Front Panel

PQDSA

PQDSB/ PQDSB1

PQDSBC

PT-HLC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI18GTLP-X BTNI24GTLP-X

2 WAY CASSETTE

Page 19: beko part2

BTNI07GTUP-X

BTNI09GTUP-X

BTNI12GTUP-X

BTNI18GTTP-X

BTNI24GTTP-X

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions Body mm

(WxDxH) Front panel mm

Weight Body kg

Front panel(Panel/Grille)

Panel Color

Noise level dBA±3

Air flow rate H/M/L CMM

Neo Plasma air purifying filter

Drain Pump

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI07GTUP-X

2.2

7,500

2.5

8,500

40

40

1, 220~240, 50

860x450x132

1,100x500x34

14.7

5.3/4.4

White

32 / 29 / 25

8.2 / 7.3 / 6.4

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI09GTUP-X

2.8

9,600

3.2

10,900

04

40

1, 220~240, 50

860x450x132

1,100x500x34

14.7

5.3/4.4

White

35 / 34 / 32

9.2 / 8.6 / 8.2

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI12GTUP-X

3.6

12,300

4.0

13,600

40

40

1, 220~240, 50

860x450x132

1,100x500x34

14.7

5.3/4.4

White

38 / 35 / 32

10 / 9.2 / 8.2

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI18GTTP-X

5.6

19,100

6.3

21,500

70

70

1, 220~240, 50

1,180x450x132

1,420x500x34

18.7

6.5/5.5

White

40 / 37 / 35

14.6 / 12.1 / 10.9

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI24GTTP-X

7.1

24,200

7.1

24,200

70

70

1, 220~240, 50

1,180x450x132

1,420x500x34

18.7

6.5/5.5

White

43 / 40 / 36

14.6 / 13.3 / 11.5

Ø9.52(3/8)

Ø15.88(5/8)

32/25

Note :1. Capacities are based on the following conditions

Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WBOutdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WBInterconnecting piping length 7.5mLevel difference of zero

Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WBOutdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5mLevel difference of zero

2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact

Front Panel

PQDSA

PQDSB/ PQDSB1

PQDSBC

PT-UUC

PT-UUD

PQDSA

PQDSB/ PQDSB1

PQDSBC

PT-UUC

PT-UUD

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

Grill Type

Moving Panel Type

BTNI07GTUP-X BTNI09GTUP-X BTNI12GTUP-X BTNI18GTTP-X BTNI24GTTP-X

1 WAY CASSETTE

Grill Type

Moving Panel Type

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 20: beko part2

BTNI07GB1S-X

BTNI09GB1S-X

BTNI12GB1S-X

BTNI15GB1S-X

BTNI18GB2S-X

BTNI24GB2S-X

LOW STATIC DUCT

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions(WxDxH) mm

Weight kg

Noise level dBA±3

E.S.P range mmAq

Air flow rate H/M/L CMM

Neo Plasma air purifying filter

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI07GB1S-X

2.2

7,500

2.5

8,500

30

30

1, 220~240, 50

820x575x190

21

29 / 26 / 24

0~4

8.5 / 7.5 / 6.5

-

Ø6.35(1/4)

Ø12.7(1/2)

32/25.4

BTNI09GB1S-X

2.8

9,600

3.2

10,900

30

30

1, 220~240, 50

820x575x190

21

31 / 29 / 26

0~4

9.5 / 8.5 / 7.5

-

Ø6.35(1/4)

Ø12.7(1/2)

32/25.4

BTNI12GB1S-X

3.6

12,300

4.0

13,600

30

30

1, 220~240, 50

820x575x190

21

33 / 30 / 29

0~4

10.5 / 9.5 / 8.5

-

Ø6.35(1/4)

Ø12.7(1/2)

32/25.4

BTNI15GB1S-X

4.5

15,400

5.0

17,100

30

30

1, 220~240, 50

820x575x190

21

34 / 33 / 31

0~4

11.5 / 10.5 / 9.5

-

Ø6.35(1/4)

Ø12.7(1/2)

32/25.4

BTNI18GB2S-X

5.6

19,100

6.3

21,500

80

80

1, 220~240, 50

1,100x575x190

26

40 / 37 / 34

0~4

16 / 14 / 12

-

Ø6.35(1/4)

Ø12.7(1/2)

32/25.4

BTNI24GB2S-X

7.1

24,200

8.0

27,300

80

80

1, 220~240, 50

1,100x575x190

26

43 / 40 / 37

0~4

19 / 17 / 15

-

Ø9.52(3/8)

Ø15.88(5/8)

32/25.4

Note :1. Capacities are based on the following conditions

Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WBOutdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WBInterconnecting piping length 7.5mLevel difference of zero

Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WBOutdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5mLevel difference of zero

2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact PQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI07GB1S-X BTNI09GB1S-X BTNI12GB1S-X BTNI15GB1S-X BTNI18GB2S-X BTNI24GB2S-X

Page 21: beko part2

BTNI07GBHS-X

BTNI09GBHS-X

BTNI12GBHS-X

BTNI15GBHS-X

BTNI18GBHS-X

BTNI24GBHS-X

HIGH STATIC DUCT

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions(WxDxH) mm

Weight kg

Noise level dBA±3

E.S.P range mmAq

Air flow rate H/M/L CMM

Neo Plasma air purifying filter

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI07GBHS-X

2.2

7,500

2.5

8,500

150

150

1, 220~240, 50

882x450x260

26

34 / 33 / 32

8.5 / 7.5 / 6

-

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI09GBHS-X

2.8

9,600

3.2

10,900

150

150

1, 220~240, 50

882x450x260

26

35 / 34 / 33

10 / 8.5 / 7.5

-

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI12GBHS-X

3.6

12,300

4.0

13,600

150

150

1, 220~240, 50

882x450x260

26

37 / 35 / 34

12 / 10 / 8.5

-

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI15GBHS-X

4.5

15,400

5.0

17,100

150

150

1, 220~240, 50

882x450x260

26

39 / 38 / 37

13.5 / 12 / 8.5

-

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI18GBHS-X

5.6

19,100

6.3

21,500

150

150

1, 220~240, 50

882x450x260

26.5

42.5 / 41 / 37

15.5 / 13.5 / 12.4

-

Ø6.35(1/4)

Ø12.7(1/2)

32/25

BTNI24GBHS-X

7.1

24,200

8.0

27,300

150

150

1, 220~240, 50

882x450x260

26.5

45 / 43 / 41

18.3 / 16.9 / 15.5

-

Ø9.52(3/8)

Ø15.88(5/8)

32/25

Note :1. Capacities are based on the following conditions

Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WBOutdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WBInterconnecting piping length 7.5mLevel difference of zero

Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WBOutdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5mLevel difference of zero

2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact PQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI07GBHS-X BTNI09GBHS-X BTNI12GBHS-X BTNI15GBHS-X BTNI18GBHS-X BTNI24GBHS-X

Page 22: beko part2

BTNI28GBGS-X

BTNI36GBGS-X

BTNI42GBGS-X

BTNI48GBRS-X

URNU76GB8S-X

URNU96GB8S-X

HIGH STATIC DUCT

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions(WxDxH) mm

Weight kg

Noise level dBA±3

E.S.P range mmAq

Air flow rate H/M/L CMM

Neo Plasma air purifying filter

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI28GBGS-X

8.2

28,000

9.2

31,500

450

450

1, 220~240, 50

1,182x450x298

38

44 / 42 / 40

6~16

25.9 / 24.1 / 21.8

-

Ø9.52(3/8)

Ø15.88(5/8)

32/25

BTNI36GBGS-X

10.6

36,200

11.9

40,600

450

450

1, 220~240, 50

1,182x450x298

38

46 / 44 / 42

6~14

32.3 / 29 / 25.3

-

Ø9.52(3/8)

Ø15.88(5/8)

32/25

BTNI42GBGS-X

12.3

42,000

13.8

43,800

450

450

1, 220~240, 50

1,182x450x298

38

48 / 46 / 45

6~12

34.5 / 32.3 / 30.7

-

Ø9.52(3/8)

Ø15.88(5/8)

32/25

BTNI48GBRS-X

14.1

48,100

15.9

51,200

450

450

1, 220~240, 50

1,230x590x380

53

45 / 43 / 41

7~20

44.8 / 40.6 / 33.3

-

Ø9.52(3/8)

Ø15.88(5/8)

32/25

URNU76GB8S-X

22.4

76,400

25.2

86,000

800

800

1, 220~240, 50

1,562x688x460

87

50 / 48 / 48

64 / 50 / 50

-

Ø9.52(3/8)

Ø19.05(3/4)

32/25

URNU96GB8S-X

28.0

95,900

31.5

107,500

800

800

1, 220~240, 50

1,562x688x460

87

52 / 50 / 50

76 / 64 / 64

-

Ø9.52(3/8)

Ø22.2(7/8)

32/25

Note :1. Capacities are based on the following conditions

Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WBOutdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WBInterconnecting piping length 7.5mLevel difference of zero

Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WBOutdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5mLevel difference of zero

2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact PQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI28GBGS-X BTNI36GBGS-X BTNI42GBGS-X BTNI48GBRS-X URNU76GB8S-X URNU96GB8S-X

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 23: beko part2

BTNI09GVES-X

BTNI12GVES-X

CEILING & FLOOR

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions(WxDxH) mm

Weight kg

Noise level dBA±3

Air flow rate H/M/L CMM

Plasma air purifying filter

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI09GVES-X

2.8

9,600

3.2

10,900

30

30

1, 220~240, 50

900x200x490

13.7

36 / 32 / 28

7.6 / 6.9 / 6.2

-

Ø6.35(1/4)

Ø12.7(1/2)

20/16

BTNI12GVES-X

3.6

12,300

4.0

13,600

30

30

1, 220~240, 50

900x200x490

13.7

38 / 36 / 30

9.2 / 7.6 / 6.9

-

Ø6.35(1/4)

Ø12.7(1/2)

20/16

Note :1. Capacities are based on the following conditions

Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WBOutdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WBInterconnecting piping length 7.5mLevel difference of zero

Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WBOutdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5mLevel difference of zero

2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact PQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI09GVES-X BTNI12GVES-X

Page 24: beko part2

URNU18GVJS-X

URNU24GVJS-X

URNU48GVLS-X

CEILING SUSPENDED

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions(WxDxH) mm

Weight kg

Noise level dBA±3

Air flow rate H/M/L CMM

Plasma air purifying filter

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit URNU18GVJS-X

5.6

19,100

6.3

21,500

63

63

1, 220~240, 50

950x220x650

24.6

42 / 40 / 37

16 / 14 / 12

-

Ø6.35(1/4)

Ø12.7(1/2)

20/16

URNU24GVJS-X

7.1

24,200

8.0

27,300

63

63

1, 220~240, 50

950x220x650

24.6

43 / 41 / 39

18 / 16 / 14

-

Ø9.52(3/8)

Ø15.88(5/8)

20/16

URNU48GVLS-X

14.1

48100

15.9

51200

63

63

1, 220 ~ 240, 50

1750x650x220

45

49/48/47

35/32/30

-

Ø9.52(3/8)

Ø15.88(5/8)

16(5/8)

Note :1. Capacities are based on the following conditions

Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WBOutdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WBInterconnecting piping length 7.5mLevel difference of zero

Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WBOutdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5mLevel difference of zero

2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact PQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI18GVJS-X BTNI24GVJS-X URNU48GVLS-X

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 25: beko part2

BTNI07GCES-X

BTNI09GCES-X

BTNI12GCES-X

BTNI15GCES-X

BTNI18GCFS-X

BTNI24GCFS-X

FLOOR STANDING WITH CASE

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions(WxDxH) mm

Weight kg

Noise level dBA±3

Air flow rate H/M/L CMM

Plasma air purifying filter

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI07GCES-X

2.2

7,500

2.5

8,500

30

30

1, 220~240, 50

1,067x203x635

27

35 / 33 / 31

8.5 / 7.5 / 6.5

-

Ø6.35(1/4)

Ø12.7(1/2)

12

BTNI09GCES-X

2.8

9,600

3.2

10,900

30

30

1, 220~240, 50

1,067x203x635

27

36 / 34 / 32

9.5 / 8.5 / 7.5

-

Ø6.35(1/4)

Ø12.7(1/2)

12

BTNI12GCES-X

3.6

12,300

4.0

13,600

30

30

1, 220~240, 50

1,067x203x635

27

37 / 35 / 33

10.5 / 9.5 / 8.5

-

Ø6.35(1/4)

Ø12.7(1/2)

12

BTNI15GCES-X

4.5

15,400

5.0

17,100

30

30

1, 220~240, 50

1,067x203x635

27

38 / 37 / 25

11.5 / 10 / 9.5

-

Ø6.35(1/4)

Ø12.7(1/2)

12

BTNI18GCFS-X

5.6

19,100

6.3

21,500

80

80

1, 220~240, 50

1,345x203x635

34

40 / 37 / 34

16 / 14 / 12

-

Ø6.35(1/4)

Ø12.7(1/2)

12

BTNI24GCFS-X

7.1

24,200

8.0

27,300

80

80

1, 220~240, 50

1,345x203x635

34

43 / 40 / 37

18 / 16 / 14

-

Ø9.52(3/8)

Ø15.88(5/8)

12

Note :1. Capacities are based on the following conditions Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WB Outdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WB Interconnecting piping length 7.5m Level difference of zero Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WB Outdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WB Interconnecting piping length 7.5m Level difference of zero2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact PQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI07GCES-X BTNI09GCES-X BTNI12GCES-X BTNI15GCES-X BTNI18GCFS-X BTNI24GCFS-X

Page 26: beko part2

BTNI07GCEUS-X

BTNI09GCEUS-X

BTNI12GCEUS-X

BTNI15GCEUS-X

BTNI18GCFUS-X

BTNI24GCFUS-X

FLOOR STANDING WITHOUT CASE

Specifications

Capacity Cooling kW

Btu/h

Heating kW

Btu/h

Power Cooling W

Input Heating W

Power Supply Ø, V, Hz

Dimensions(WxDxH) mm

Weight kg

Noise level dBA±3

Air flow rate H/M/L CMM

Plasma air purifying filter

Piping Liquid mm(inch)

Connection Gas mm(inch)

Drain(OD/ID) mm

Model Unit BTNI07GCEUS-X

2.2

7,500

2.5

8,500

30

30

1, 220~240, 50

978x190x639

20

35 / 33 / 31

8.5 / 7.5 / 6.5

-

Ø6.35(1/4)

Ø12.7(1/2)

12

BTNI09GCEUS-X

2.8

9,600

3.2

10,900

30

30

1, 220~240, 50

978x190x639

20

36 / 34 / 32

9.5 / 8.5 / 7.5

-

Ø6.35(1/4)

Ø12.7(1/2)

12

BTNI12GCEUS-X

3.6

12,300

4.0

13,600

30

30

1, 220~240, 50

978x190x639

20

37 / 35 / 33

10.5 / 9.5 / 8.5

-

Ø6.35(1/4)

Ø12.7(1/2)

12

BTNI15GCEUS-X

4.5

15,400

5.0

17,100

30

30

1, 220~240, 50

978x190x639

20

38 / 37 / 35

11.5 / 10 / 9.5

-

Ø6.35(1/4)

Ø12.7(1/2)

12

BTNI18GCFUS-X

5.6

19,100

6.3

21,500

80

80

1, 220~240, 50

1,256x190x639

27

40 / 37 / 34

16 / 14 / 12

-

Ø6.35(1/4)

Ø12.7(1/2)

12

BTNI24GCFUS-X

7.1

24,200

8.0

27,300

80

80

1, 220~240, 50

1,256x190x639

27

43 / 40 / 37

18 / 16 / 14

-

Ø9.52(3/8)

Ø15.88(5/8)

12

Note :1. Capacities are based on the following conditions

Cooling- Indoor temp. 27°C[80.6°F]DB / 19°C[66.2°F]WBOutdoor temp. 35°C[95°F]DB / 24°C[75.2°F]WBInterconnecting piping length 7.5mLevel difference of zero

Heating- Indoor temp. 20°C[68°F]DB / 15°C[59°F]WBOutdoor temp. 7°C[44.6°F]DB / 6°C[42.8°F]WBInterconnecting piping length 7.5mLevel difference of zero

2. Due to our policy of innovation some specifications may be changed without notification

* AccessoriesModel

Dry Contact PQDSA

PQDSB/ PQDSB1

PQDSBC

Without case(1 contact point)

With case(1 contact point)

With case(2 contact point)

BTNI07GCEUS-X BTNI09GCEUS-X BTNI12GCEUS-X BTNI15GCEUS-X BTNI18GCFUS-X BTNI24GCFUS-X

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory

Page 27: beko part2

Tropical Multi V III

Tropical Multi V M

iniTropical M

ulti V Water II

Multi V series Indoor unit

eco VV-N

et & Accessory