Beginning of an era of remote I/O solutions in India
Messung Systems is certified for ISO 9001:2000(Standard for Quality Management System)
ISO 9001 : 2000
Certificate:04100 20047173-E3
TM
A U T O M A T I O N P E O P L E
R e m o t e I / O s
Smart AccessoriesEasy Mounting Efficient I/O Wiring Arm
Same as 20 terminals size.No change required in junction box design.
Compact
�
�
Base Unit + 3 expansion units. Each unit handles64 I/O points per remote node
16 I/O points
Expansion2 Expansion3Expansion1BaseNode ID n
64 I/O Points Per Node
Afte
r
Remote I/O System
CP-5232-BO
Standard Features:
Built in CANopen Master Functionality via CANopen Interface Port
�
�
�
�
�
�
High Speed Processing
- Bit/ Byte/ Word Execution - 0.6 to 0.8 µs
2 K Inputs & 2 K Output Points (Local + RiX)
Diagnostics Status LEDs on NG523X CPU:
- Common Error Indication (I/O error)
- Application Interlocking on error via System Variables
Modbus RTU Protocol (Master/ Slave) on serial ports
Huge Memory
- 324 KB Application Program (Flash) - 1 MB Source Code (Flash)
- 32 KB Marker (Battery Back-up) - 64 KB Data (Battery Back-up)
- 64 KB File Marker (Battery Back-up)
Easy I/O Configuration through CoDeSys Programming Software
Master CPU CP 523X Series
PLC System
Messung Systems:Your Partner In Technological Excellence
At a Glance
Standard 5-pinNetwork Connector
Simple Rotary Switches for Node ID Settings
Onboard I/O Status LED Indications
Onboard Network Status LED Indications
I/O connection LabelAvailable for guidance
Easy Push Type Terminal
DIN Mounting Clip
Test Point forMultimeter
I/O Cable Connection1 sq.mm
Remote I/O System
For Your Automation Needs
Presenting
�
�
�
�
Promoted by international organization
CAN technology is based on International Standard
ISO 11898
Most secured control network:
- Self reliant, error detection & self correction
- Undetected network error possibility 1 in a 1000 yrs
Carrier Sense Multiple Access Non Destructive Arbitration
(CSMA-NDA) Technology
- Offers maximum thoroughput
- Best Real time response even at a lower baud rate
�
�
�
Powerful network diagnostics:
- Node failure detection
- Missing node detection
- Supports hot replacement
Very robust EMC behaviour
Lower cost of networking, simple two shielded
twisted cable
CANopen Features
Centralised I/O System
Cluttered Machine Wiring
Complex Panel Wiring
Befo
re
Limitations BenefitsReducedMachineWiring
ReducedNo. of Joints
IncreasesReliability
MinimumPanelSpace
Required
LowersInstallation &
CommissioningCosts
ReducedMaintenance
Time
In an industrial scenario, sensors & actuators are key elements embedded in the machine & process control. These sensors &
actuators are generally spread over a distance. Discrete wiring to each of these devices has always been cumbersome, time
consuming & error prone. Remote I/Os connected on the field bus are designed as an intelligent alternative. They are placed near
these field elements & are wired locally.
Messung Systems introduces RiX series Remote I/O units based on highly reliable CANopen field bus technology. RiX Remote I/O
units are designed to be mounted near these field elements (e.g. in junction boxes & in push button panels) for individual I/O
connections. Further RiX units are connected to the master CPU using a two shielded twisted pair network cable.
What is Remote I/O?
ClutteredMachineWiring
HighMaintenance
Time
HighInstallation &
CommissioningCosts
ExcessPanelSpace
Required
AdditionalJoints
ReduceReliability
RiX FRC 6940/6941cable betweenbase / expansionunit
T Junction 6930 - for connecting eachdevice on a trunk line with drop lines
RiX I/OWiring Arm 6920
UnplugMounting Clip
Panel Mount clips areplugged on the bottom sidewhen the product is delivered.
2 or 3 wire sensors can be connecteddirectly. Sink/Source selectable input.
Input Signal
24 V DC
0 V DC
ProxySwitch
Cross
Horizontal
Powerpacked Features
· Auto Network Baud Rate Detected by RiX Base
Units
· Programmable Pulse Catch
· Data Transmission on I/O Status Change to
Reduce Network Traffic
· Replacement of the Faulty Unit Without
Disturbing the Live Network
· I/O Error Indication on CPU if Expansion Unit
Gets Disconnected
· Diagnostics Status LEDs on Each module:
- Status of Base Unit
- Status of Expansion Module
Highlighting Features
R e m o t e I / O s
Messung Systems is the pioneer of indigenous PLC technology and has given the world many new-age automation products. The
backbone of Messung Systems is its R & D division that is fiercely dedicated to creating automation products that can completely
transform factory working.
Today Messung Systems boasts of 35,000 successful PLC installations in diverse industries like automobile, pharmaceutical, plastic,
textile, printing and food processing. With an enviable turnover and a string of delighted customers behind it, Messung Systems is
moving ahead, creating landmark products in automaton.
RiX CANopen Remote I/O Solutions: A new era begins...
Salient Features
�
�
�
Network upto 31 NodesMaximum Network Length 500 mtrsCANopen Master CPU (CP 523X) sets Baudrate for Total Network
�
�
Replacement of the Faulty Unit without Disturbing the LiveNetworkI/O Error Indication on CPU if Expansion Unit gets Disconnected
01. Automotive / Automobile
- SPM (Special Purpose Machine)
- Production Control System
- Material Handling System - Conveyor
- ANDON Display System on Assembly Line
- Electroplating Plant - POWER RAIL
or MONORAIL
- Ultrasonic Cleaning System
- Press
- Transfer Line
- Intelligent Hydraulic & Pneumatics Panel
- Production Monitoring
02. Process
04. HVAC - Aircon
05. Utility Sector
- Water Treatment Plant- Asbestos Sheet Making Plant
- Climate Control- AC Automation
- Fire Control at Power Stations- Lift / Escalator - Residential or Commercial- Furnace / Boiler
03. Intelligent MCC Panel
06. Food & Beverage
07. Supervisory system for DG set/Furnace/Boiler/ Compressor etc.
- Filling & Bottling Line- Biscuit Mfg. Line- Ovens for Bread making Machine- Edible Oil Processing Plant
Vast Application Areas
Baudra
tein
Kbps
Distance in Mtrs.
Distance V/s Baudrate
25 100 250 500
125
250
500
1,000
Network upto 31 nodes
Expansion3
Node ID 2
Node ID 31
Base Expansion1 Expansion2 Expansion3
Expansion2Expansion1Base
4110 4632 4632 4532
CA
NO
pen
Netw
ork
4110
4632
4632
4532
Node ID 2
Node ID 3
RiX Expansion
Node ID 31
CANopen Master PLC SystemCP523X Series
CoDeSys Software
TerminatingResistor
TerminatingResistor
RiX Base
RiX Expansion
RiX Base
RiX Expansion
RiX Base
RiX Base
+24 VDCNetwork Power Supply
IBM PCCompatible
RiX Expansion
RiX Expansion
24 V Power SupplyTrunk Line Drop Line Expansion CableFRC T Junction
+24 VDCNetwork Power Supply
Node ID 4
Typical Remote I/O Scheme
Configuration Elements
���
System with CP 523X Series CPU
RiX Remote I/O Units
Network Power Supplies of Suitable
Current Rating
����
Network Cable - Two shielded Twisted Pair
Terminating Resistor
T - Junction
CoDeSys Software
Technical Specifications
CANopen Slave,RiX Remote I/O Units
Ordering Code Item Description
CP 5230-B0 Basic CPU with 1 PG Port, 1 CANopen Port
CP 5231-B0 Basic CPU with 1 PG Port,1 CANopen Port & 1 Auxiliary Port
CP 5232-B0 Basic CPU with 1 PG Port,1 CANopen Port & 2 Auxiliary Ports
CP 5232-P4 CPU with 2 HSC + 2 PTO, 1 PG Port,1 CANopen Port & 2 Auxiliary Ports
4110 Power Supply - Input: 220 VAC
4112 Power Supply - Input: 24 VDC
4113 Power Supply - Input: 90 - 260 VAC,Output: 24 VDC, 0.4 A
5900 Basic Plate without I/O
4930 Basic Plate with 3 I/O
4932 Basic Plate with 5 I/O
4906 Basic Plate with 8 I/O
*For more details please refer to the installation manual
PWR
RUN ERR
STS 0 1 2 3 4 5 6 7
10 11 12 13 14 1715 16
Base Unit : 16pt. 24 VDC InputC6616
Node Idx10 x1
Inputs
Inputs
140
5046
50
54
Ordering Code Item Description
C6616 RiX CANopen Base Unit 16 Point, 24 VDC sink/source Input
C6709 Base Unit 8 Point,1 A, Relay Output, 24 VDC/ 110 VAC/ 220 VAC Potential free Contact Type
C6710 Base Unit 8 Point, 24 VDC Source, 1.5 A Output
C6716 Base Unit 16 Point, 24 VDC Source, 250 mA Output
C6418 Base Unit 8 Point, 24 VDC sink/source Input + 8 Point,24 VDC Source, 250 mA Output
C6417 Base Unit 8 Point, 24 VDC sink/source Input + 6 Point,500 mA, Relay Output, 24 VDC/ 110 VAC/ 220 VAC
X6616 Expansion Unit - 16 Point, 24 VDC sink/source Input
X6609 Expansion Unit - 8 Point, 110 / 220 VAC Input
X6709 Expansion Unit - 8 Point,
X6710 Expansion Unit 8 Point, 24 VDC Source, 1.5 A Output
X6716 Expansion Unit 16 Point, 24 VDC, Source, 250 mA Output
X6418 Expansion Unit 8 Point, 24 VDC sink/source Input + 8 Point,24 VDC Source, 250 mA Output
X6417 Expansion Unit 8 Point, 24 VDC sink/source Input + 6 Point,500 mA, Relay Output, 24 VDC/ 110 VAC/ 220 VAC
C6609 RiX CANopen Base Unit 8 Point, 110 VAC/ 220 VAC Input
RiX CANopen
RiX CANopen
RiX CANopen
RiX CANopen
RiX CANopen
VAC
1 A, Relay Output, 24 VDC/ 110 VAC/ 220 VAC Potential free Contact Type
Note : All Dimensions are in mm
CANopen Master,Nexgen 5000 PLC System
Dimensional Details
17
�
�
�
RiX Analog Input-Output UnitsConnectivity to Nexgen-2000 PLCsRiX Key Panel
Coming Prospects
MESSUNG AREA OFFICES
NEW DELHI
MESSUNG SYSTEMSTEL:+91(011)29216128 /
29226129FAX:+91(011)29226730
BARODA
MESSUNG SYSTEMSTEL:+91(0265)2314669 /
2358137FAX:+91(0265)2333307
PUNE
MESSUNG SYSTEMS91(020)27102172
FAX:+91(020)27102173
TEL:+
HYDERABAD
MESSUNG SYSTEMSTEL:+91(040)27722519 /
27720308FAX:+91(040)27722519
BANGALORE
MESSUNG SYSTEMSTEL:+91(080)25092119FAX:+91(080)25320480
MUMBAI
MESSUNG SYSTEMSTEL:+91(022)26674308 /
56949564FAX:+91(022)26674309
AREA DISTRIBUTORS
CHENNAI
C/MOS PROCESSORS91(044)26287653 /
26217942FAX:+91(044)26217943
TEL:+
KOLKATA
TTS SYSTEMATIX PVT. LTD91(033)24635645
FAX:+91(033)24635646
TEL:+
BANGALORE
LEONARDO AUTOMATION(080)23283030
FAX:+91(080)23282613
TEL:+91
ww
w.inte
ricsdesig
ns.c
om
EL-2, J BLOCK, M.I.D.C. BHOSARI,PUNE - 411 026. INDIATEL : +91(020)27102000 / 27102125FAX : +91(020)27102130email : [email protected] : www.messungautomation.com
MESSUNG SYSTEMSMANUFACTURER OF PLCs & HMIs
TM
CANopen Network Max 31 Nodes (Up to 500 mtrs)
Max. Units per Node 1 Base + 3 Expansion Units
Operating Temperature 0 to 55 C
Relative Humidity 5 to 90% Non Condensing
Noise Immunity2 KV Conductive on NetworkPower Supply1 KV Capacitiveon Network Cable
Shock IEC61131-2 Operating:15g (DIN rail & Panel Mounting)
Vibration IEC61131-2 Operating:5 to 150 Hz, 1g, 3.5mm Amplitude
Mounting DIN rail or Panel Mount
Protection IP 20
I/O Connections 20-pin 5.00 mm Pitch Push TypeFixed Terminal Block
I/O Wire Size Recommended RiX Input Wiring: 0.5 sq. mm per i/pRIX Output Wiring: 0.75 sq. mm per o/p
Network Connections 5-pin 5.08 mm Pitch Screw TypeOpen Style Connector
Network Cable R LAPP Cable LI2YCY 2 x 2 x 0.22for Network upto 100 mtrsLeoni / Belden / Helukabel ThickCAN Cable for Network Above 100 mtrs
Unit Power Supply 11 to 30 VDC Through 5-pinNetwork Connector
Network Power Supply 24 VDC, 5 A*
Power Supply Protection Reverse Polarity
Dimensions (Base / 140 mm 54 mm 46 mm (W H D)
Baud Rate Auto Baud Detection(10, 20, 50, 125, 250, 500, 1000 Kbps)
CANopen Version CIA Standard DS 301 Version 4.02
°
Operations IEC 1000-4-4
ecommended
x x x xExpansion Unit)
RiX Spares & Accessories
6929 RiX Spare Part - RiX 5 Pin Connector, for Network Connection
6920 RiX Accessory - RiX I/O Wiring Arm, 20 Pin Terminals (Push Type)
6121 RIO Network Cable 4 Core Shielded, (LAPP Make)Li2YCy(TP) 2 x 2 x 0.22 Unitronic
6930 RiX T - Junction for Easy Multidrop Connections
6931 RiX Power Junction for Easy Power
6940 RiX Spare Part - RiX Cable Between Base/ Expansion & Expansion,FRC Type, L = 70 mm
6941 RiX Spare Part - RiX Cable Between Base/ Expansion & Expansion,FRC Type, L = 350 mm
Connections
16