16
Glastender, Inc. • 5400 North Michigan • Saginaw, MI • 48604-9780 • 989.752.4275 • 800.748.0423 • Fax 989.752.4444 • www.glastender.com A family company manufacturing in the USA www.glastender.com BEER SYSTEMS INDEX Product Page Beer Line Chillers ....................................................... 5.01 Line Chiller Racks and Stands .................................... 5.02 Beer Towers Column Towers....................................................... 5.03 Tee Towers .............................................................. 5.04 Undercounter Towers ............................................. 5.05 Wall Mount Towers ................................................ 5.06 Wood Barrel Towers ............................................... 5.07 Beer Systems Spec Index

Beer Systems A a coa auacturg te Spec Index  · G I n m s mI F .glastender.com A a coa auacturg te beer sysTems Index Product Page Beer Line Chillers

  • Upload
    dotu

  • View
    212

  • Download
    0

Embed Size (px)

Citation preview

Glastender, Inc. • 5400 North Michigan • Saginaw, MI • 48604-9780 • 989.752.4275 • 800.748.0423 • Fax 989.752.4444 • www.glastender.com

A family company manufacturing in the USAwww.glastender.com

beer sysTems Index

Product PageBeer Line Chillers ....................................................... 5.01Line Chiller Racks and Stands .................................... 5.02

Beer Towers Column Towers ....................................................... 5.03 Tee Towers .............................................................. 5.04 Undercounter Towers ............................................. 5.05 Wall Mount Towers ................................................ 5.06 Wood Barrel Towers ............................................... 5.07

Beer SystemsSpec Index

Printed in USASpecifications subject to change without notice. For current specifications please visit our website.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444

www.glastender.com

Approval/Notes:

Project:Item #: Qty:Model #:

AIA#

SIS#

A family company manufacturing in the USAwww.glastender.com

Beer Line Chillers

Rev. 05-16-185.01

1/3 HP Beer Line ChillerModel: BLC-1/3-E

BLC-1/3-E

BLC-1/3-2

1/3, 1/2, and 3/4 HP Beer Line Chillers with Remote Installable Control PanelModels: BLC-1/3, BLC-1/3-2, BLC-1/2, BLC-1/2-2, BLC-3/4, BLC-3/4-2

Standard FeatureS:• Glycol connections with flared fittings for easy service access• Durable black vinyl-clad exterior with 16 gauge galvanized

steel base• Stainless steel, CFC-free, foamed-in-place insulated glycol bath• High efficiency heat exchanger minimizes glycol bath size to

one gallon• Front located glycol filling port

Standard FeatureS:• Control panel is removable and includes wall bracket for

remote installation• Glycol connections with flared fittings for easy service

access• Durable black vinyl-clad exterior with 16 gauge galvanized

steel base• Stainless steel, CFC-free, foamed-in-place insulated glycol

bath• High efficiency heat exchanger minimizes glycol bath size to

one gallon• Front located glycol filling port• Digital temperature control with LCD display• Over-sized condenser coil for maximum efficiency• Clear glycol bath cover for easy visual inspection• Available with two recirculating pumps (designated by “-2”

suffix in model number)BLC-3/4-2

Conforms to ANSI/UL STD 471Certified to CSA STD

C22.2 No. 120

Conforms to ANSI/UL STD 471Certified to CSA STD

C22.2 No. 120

Conforms to ANSI/UL STD 471Certified to CSA STD

C22.2 No. 120

Dimensional Information

5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA

Remote Draft Beer Line Chillers

The Glastender exclusive, patented beer line chiller design houses the heat exchanger inside the condensing unit compartment. This unique feature allows the control panel with glycol bath and recirculating pump(s) to be easily installed separate from the condensing unit in a more conveniently accessible location. Simply remove the control panel from the condensing unit cabinet and mount it in the desired location. Only glycol and electrical lines need to be run between the control panel and the condensing unit cabinet.

Glycol return from beer tower to heat exchanger

Glycol line from pump to beer tower

Glycol line from bath to pump

Recirculating pump

.94 gallon glycol bath

Condensing unit andheat exchanger cabinet

Glycol line from heat exchanger to bath

Electrical connection between condensing unit and control

panel by local electrician

Digital temperature control with LCD display

Power cord for unit

Photo shows BLC-1/3 in an installation setting with the control panel installed remotely from the condensing unit cabinet.

Remote Mounted Control Panel Installation Details

Model No. BLC-1/3-E BLC-1/3 BLC-1/3-2 BLC-1/2 BLC-1/2-2 BLC-3/4 BLC-3/4-2Dimensions† Length 27" 27" 27" 27" 27" 27" 27"

Width 21-1/4" 25-5/8" 25-5/8" 25-5/8" 25-5/8" 25-5/8" 25-5/8"Height 14-3/4" 16" 16" 16" 16" 16" 16"† Note: A minimum six inch clearance should be allowed around the entire unit for proper air flow.

Additional clearance should be considered above and in front of the unit for service access.

Electrical Voltage 120V 120V 120V 120V 120V 220V 220VFrequency 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 Hz 60 HzPhase 1ø 1ø 1ø 1ø 1ø 1ø 1øFLA 13 13 18.6 13.5 19.5 10.1 12.9DedicatedCircuit

20A 20A 30A 20A 30A 20A 20A

ElectricalConnection

Cord & PlugNEMA 5-20P

Cord & PlugNEMA 5-20P

Hard Wire Cord & PlugNEMA 5-20P

Hard Wire Cord & PlugNEMA 6-20P

Cord & PlugNEMA 6-20P

Refrigerant R134a R134a R134a R134a R134a R134A R134ARefrigerant Charge 14 oz. 26 oz. 26 oz. 30 oz. 30 oz. 35 oz. 35 oz.Compressor 1/3 HP 1/3 HP 1/3 HP 1/2 HP 1/2 HP 3/4 HP 3/4 HPCapacities* 2,175 BTU/hr 2,175 BTU/hr 2,175 BTU/hr 3,300 BTU/hr 3,300 BTU/hr 6,375 BTU/hr 6,375 BTU/hr

* Note: Rated capacities assume maximum operating ambient temperature of 80°F.Heat Rejection (BTU/hr) 5,323 BTU/hr 5,323 BTU/hr 7,616 BTU/hr 5,527 BTU/hr 7,984 BTU/hr 7,581 BTU/hr 9,683 BTU/hrMax Distance to Taps 125 ft. 125 ft. 125 ft. 250 ft. 250 ft. 400 ft. 400 ft.Circulating Pumps 60 gph 60 gph 60 gph 60 gph 60 gph 60 gph 60 gph

Glycol Bath Capacity .94 gal .94 gal .94 gal .94 gal .94 gal .94 gal .94 gal.Shipping Weight LBS (kg) 128 (58.1) 150 (68.0) 163 (73.9) 153 (69.4) 166 (75.3) 175 (79.5) 193 (87.7)

Printed in USASpecifications subject to change without notice. For current specifications please visit our website.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444

www.glastender.com

Approval/Notes:

Project:Item #: Qty:Model #:

AIA#

SIS#

A family company manufacturing in the USAwww.glastender.com

5.02

Line Chiller Racksand Stands

LCR-GO

LCS-S

Rev 08-07-15

LCR-G, LCR-S, LCR-GE, LCR-SE, LCR-SO, LCR-GO, LCS-G, LCS-S

Standard Features

Line Chiller Rack Product Details

• All 16 gauge galvanized or stainless steel construction• Pre-drilled mounting holes to fit Glastender line chiller

models• Three models of line chiller racks to accommodate various

models of Glastender line chillers• Adjustable feet on line chiller stands for leveling• One line chiller stand fits all models of Glastender line

chillers• Line chiller stands feature bottom shelf for miscellaneous

storage

LCR-GE

Line Chiller Stand Product Details

LCS-S• All 16 gauge stainless steel• Designed for use with all Glastender line chiller models

LCS-G• All 16 gauge galvanized steel• Designed for use with all Glastender line chiller models

LCR-S• All 16 gauge stainless steel• Designed for use with line chiller models BLC-1/3,

BLC-1/3-2, BLC-1/2, and BLC-1/2-2LCR-G• All 16 gauge galvanized steel• Designed for use with line chiller models BLC-1/3,

BLC-1/3-2, BLC-1/2, and BLC-1/2-2LCR-SE• All 16 gauge stainless steel• Designed for use with line chiller model BLC-1/3-E

LCR-GE• All 16 gauge galvanized steel• Designed for use with line chiller models BLC-1/3-E

LCR-SO• All 16 gauge stainless steel• Designed for use with line chiller model LC-47

LCR-GO• All 16 gauge galvanized steel• Designed for use with line chiller model LC-47,

BLC-1/3-2, BLC-1/2, and BLC-1/2-2NOTE: Line chiller racks must be properly mounted to a structural wall.

5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA

26 3/8"

1"

1"

7"

26 3/8"

1"

24"3"

38"

1"

7"

38"

3"

24"

FRONT ELEVATION SIDE ELEVATIONPLAN VIEW

ADJUSTABLE LEGS

REAR PLATE TO MOUNT ASSORTED

GAUGES

Line Chiller Racks and Stands

LCR-G and LCR-S

28" 23-1/4"

28"

23-1/4"

13"

FRONT ELEVATIONPLAN VIEW SIDE ELEVATION

MOUNTING HOLES

28" 27"

28"

27"

14"

FRONT ELEVATIONPLAN VIEW SIDE ELEVATION

MOUNTING HOLES

LCR-GE and LCR-SE

LCR-GO and LCR-SO

28"

12"

21-3/8"

28"

21-3/8"

FRONT ELEVATIONPLAN VIEW SIDE ELEVATION

MOUNTING HOLES

LCS-G and LCS-S

Dimensional Information

5.02 - page 2

Printed in USASpecifications subject to change without notice. For current specifications please visit our website.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444

www.glastender.com

Approval/Notes:

Project:Item #: Qty:Model #:

AIA#

SIS#

Standard Features

Specifications

Rev. 11-08-175.03

Drains• Drain pan models - 1/2″ tailpiece

Materials• 20 gauge stainless steel or brass parts include: head,

column, drain pan, and perforated inserts• 16 gauge stainless steel parts include: inner column

stiffener brackets• 16 gauge galvanized steel parts include: base plate

and faucet stiffeners• 11 gauge stainless steel parts include: inner column

base plateShank Sizes• 1/4″ I.D. with 3/16″ fittings

• All stainless steel construction (brass is optional)• Integral surface mount drain pan with lift-out perforated insert• 1/4″ shanks with 3/16″ restriction lines• Available in grainline stainless, mirror finish stainless, or

polished brass• Available with foamed-in-place cold plate assembly for

recirculating system• Available without drain pan (specify suffix ‘-LD’ on the

model number)• Available with one, two, or three faucets• All models include all stainless steel faucets and shanks• Unique internal support system for solid mounting• Base plate serves as template for hole cutting• Available with rinser faucet extension to the left or right

of the drain pan. Specify accessory model number RFSS, RFMF, or RFPB for stainless steel, mirror finish, or polished brass respectively.

CT- -

CT-3-SS

CT-3-SS with optional Rinser Faucet Extension

Size:Specify the number of

faucets from 1 to 3.

Finish:SS = Stainless steelMF = Mirror finishPB = Polished brass

Column Towers

NOTE: Faucet handles not included.

A family company manufacturing in the USAwww.glastender.com

Rinser Faucet Installation Notes

• Important: Unit must be installed in conformance with applicable federal, state, and local plumbing codes, including adequate backflow when required.

• Install in-line water regulator (included).• A separate shut-off valve is recommended

(not included).

03012383Rinser Faucet Assembly

4004503Conforms to NSF/ANSI STD 372

Rinser Faucet (optional)• Accepts 3/8″ cold water lead• 30 psi water pressure regulator included

NOTE: Rinser faucets are not intended for use with towers mounted to a refrigerator due to risk of water line freeze up.

4004503Conforms to NSF/ANSI STD 18

Dimensional Information

5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA

Column Towers

NOTE: Faucet handles not included.LD - LESS DRAIN RF - RINSER FAUCET

5-1/8"

5-1/8"

5-1/8"5-1/8"

14" 19"

19"14"

12" 12"

4"

1-1/4"

16-1/8"

4" 4" 4"

17-3/8" 17-3/8"

16-1/8" 17-3/8" 17-3/8"

1-1/4"

1-1/4" 1-1/4"

12"12"

12-3/8"12-3/8"12-1/2"

PLAN VIEWPLAN VIEW PLAN VIEW

FRONT ELEVATION

SIDE ELEVATION SIDE ELEVATION SIDE ELEVATION

FRONT ELEVATION FRONT ELEVATION

Printed in USASpecifications subject to change without notice. For current specifications please visit our website.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444

www.glastender.com

Approval/Notes:

Project:Item #: Qty:Model #:

AIA#

SIS#

Standard Features

Specifications

Rev. 11-08-175.04

BT-10-MFR

• All stainless steel construction (brass is optional)• Integral surface mount drain pan with lift-out perforated insert• 1/4″ shanks with 3/16″ restriction lines• Available in grainline stainless, mirror finish stainless, or

polished brass• Available with insulated cold plate assembly for

recirculating system• Available without drain pan (specify suffix ‘-LD’ on the

model number)• Available in 4, 5, 6, 8, 10, and 12 faucet sizes• All models include all stainless steel faucets and shanks• Foamed-in-place insulated column for extra rigidity• Unique internal support system for solid mounting• Base plate serves as template for hole cutting• Available with rinser faucet extension to the left or right

of the drain pan. Specify accessory model number RFSS, RFMF, or RFPB for stainless steel, mirror finish, or polished brass respectively.

BT- - Finish:

SS = Stainless steelMF = Mirror finishPB = Polished brass

Size:Specify the number of

faucets from 4, 5, 6, 8, 10, 12

Tee Towers

Drains• Drain pan models - 1/2″ tailpiece

Materials• 20 gauge stainless steel or brass parts include: head,

column, drain pan, and perforated inserts• 16 gauge galvanized steel parts include: subsurface head

stiffener and base plate• 11 gauge stainless steel parts include: inner column base

and top plate and tower head mounting plateShank Sizes• 1/4″ I.D. with 3/16″ fittings

BT-5-SSR with optional Rinser Faucet Extension

NOTE: Faucet handles not included.

A family company manufacturing in the USAwww.glastender.com

Rinser Faucet Installation Notes

• Important: Unit must be installed in conformance with applicable federal, state, and local plumbing codes, including adequate backflow when required.

• Install in-line water regulator (included).• A separate shut-off valve is recommended

(not included).

03012383Rinser Faucet Assembly

4004503Conforms to NSF/ANSI STD 372

4004503Conforms to NSF/ANSI STD 18

Rinser Faucet (optional)• Accepts 3/8″ cold water lead• 30 psi water pressure regulator included

NOTE: Rinser faucets are not intended for use with towers mounted to a refrigerator due to risk of water line freeze up.

Dimensional Information

5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA

Tee Towers

NOTE: Faucet handles not included.

SINGLE COLUMN TEE TOWERFAUCETS 4 5 6

“A” WIDTH 14″ 17″ 20″

DOUBLE COLUMN TEE TOWERFAUCETS 8 10 12

“B” WIDTH 26″ 32″ 38″

“C” WIDTH 12″ 15″ 18″

TEE TOWER W/RINSER FAUCETSINGLE COLUMN

FAUCETS 4 5 6

“D” WIDTH 14″ 17″ 20″

“E” WIDTH 19″ 22″ 25″

DOUBLE COLUMNFAUCETS 8 10 12

“F” WIDTH 26″ 32″ 38″

“G” WIDTH 31″ 37″ 43″

“H” WIDTH 12″ 15″ 18″

BT FRONT ELEVATION

BT FRONT ELEVATION

BT -LD FRONT ELEVATION

BT -LD SIDE ELEVATION

BT -RF SIDE ELEVATION

BT SIDE ELEVATION

BT -LD FRONT ELEVATION

BT -RF FRONT ELEVATION BT -RF FRONT ELEVATION

BT -LD PLAN VIEW

BT -LD PLAN VIEW

BT -RF PLAN VIEW BT -RF PLAN VIEW

BT PLAN VIEW

BT PLAN VIEW

5"11-7/8"

1-1/4"

4-7/8"

A

5"11-7/8"

4-7/8"

A

11-7/8"

1-1/4"

4-7/8"

5"

B

BC

12"

11-7/8"

4-7/8"

5"

B

BC

5-1/8"

16-3/4"12-1/2"

5-1/8"

A

5-1/8"

F

11-7/8"

1-1/4"

4-7/8"

5"

GH

12"

1/2" DRAIN

18"12-1/2"

5-1/8"

12"

D

5"

11-7/8"

1-1/4"

4-7/8"

E

12"

18"

1/2" DRAIN

12-1/2"

5-1/8"

12"

A

12"

Printed in USASpecifications subject to change without notice. For current specifications please visit our website.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444

www.glastender.com

Approval/Notes:

Project:Item #: Qty:Model #:

AIA#

SIS#

Standard Features

Specifications

Rev. 06-07-165.05

• All stainless steel construction• 1/4″shankswith3/16″restrictionlines• Includes insulated cold plate assembly for recirculating system• Available in 4, 5, 6, 8, 10, and 12 faucet sizes• Includesstainlesssteelfaucetsandshanks

NOTES:1. Undercounter towers do not include a drainpan. Glastender

offers a free standing underbar Beer Drainer, see spec guide page 3.31.

2. Beerandglycollinescanbelocatedtoexitthebackorbottomof the tower - please specify exit location when ordering.

UC- -SSRSize:

Specify the number of faucets from 4, 5, 6, 8, 10, 12

UC-4-SSR

UC-4-SSR shown installed under bar top

UndercounterTowers

Mounting Details

Bar Top

Materials• 20 gauge stainless steel

Shank Sizes• 1/4″I.D.with3/16″fittings

Beer and Glycol Lines• Must specify when ordering if lines are to exit thebackorbottomofthetower

NOTE: Faucet handles not included.

A family company manufacturing in the USAwww.glastender.com

4004503Conforms to NSF/ANSI STD 18

SIDE ELEVATION

FRONT ELEVATION

PLAN VIEW

4 1/4"

4 1/4"

3/4"

A

5 5/8"

5 5/8"

4 7/8"

A

Dimensional Information

5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA

Undercounter Towers

4....................... 14" 5....................... 17" 6....................... 20" 8....................... 26"10....................... 32"12....................... 38"

NUMBER OFFAUCETS

“A”WIDTH

UNDERCOUNTERTOWERS

NOTE: Faucet handles not included.

Printed in USASpecifications subject to change without notice. For current specifications please visit our website.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444

www.glastender.com

Approval/Notes:

Project:Item #: Qty:Model #:

AIA#

SIS#

Standard Features

Specifications

Rev. 08-01-165.06

Drains• Drain pan models - 1/2″ tailpiece

Materials• Stainless steel faucets and shanks• Stainless steel body and drain pan• Galvanized steel inner structure on glycol chilled models

Shank Sizes• 1/4″ I.D. with 3/16″ fittings

• All stainless steel construction• Integral drain pan with lift-out perforated inserts• 1/4″ shanks with 3/16″ restriction lines• Available with insulated cold plate assembly for

recirculating system• Available in 4,5,6,8,10, 12 faucet sizes• Includes stainless steel faucets and shanks• Built-in wall mounting bracket• Removable front cover for access to shanks

WT- -SSSize:

Specify the number of faucets from 4,5,6,8,10,12.

WT-6-SS

Wall MountTowers

NOTE: Faucet handles not included.

A family company manufacturing in the USAwww.glastender.com

4004503Conforms to NSF/ANSI STD 18

A

12"

WALL MOUNT TOWERS

NUMBER OFFAUCETS

45681012

"A"WIDTH

14"17"20"26"32"38"

SIDE ELEVATION

FRONT ELEVATION PLAN VIEW

1/2" DRAIN

A

5-11/16"

16"10-7/8"

1-1/4"

16"

Dimensional Information

5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA

Wall Mount Towers

NOTE: Faucet handles not included.

Printed in USASpecifications subject to change without notice. For current specifications please visit our website.

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444

www.glastender.com

Approval/Notes:

Project:Item #: Qty:Model #:

AIA#

SIS#

A family company manufacturing in the USAwww.glastender.com

Standard Features

Specifications

01-19-185.07

Drains •Drainpanmodels-1/2″tailpieceMaterials • 18gaugestainlesssteelpartsinclude:drainpan andperforateddrainpaninserts

• 20gaugestainlesssteelpartsinclude:innertower head

Shank Sizes • 1/4″I.D.with3/16″fittings

• Oakwoodbarrelconstruction• Includesseparatestainlesssteelsurfacemountdrainpanwithlift-outperforatedinsert

• 1/4″shankswith3/16″restrictionlines• Availableinflatblackornaturalunfinished• Availablewithinsulatedcoldplateassemblyforrecirculatingsystem

• Availableinthreethroughsixfaucetsizes• Includesstainlesssteelfaucetsandshanks• Includeswallmountingbrackets

WB- - Size:

Specifythenumberoffaucetsfrom3to6.

Finish:B = FlatBlackN = Natural

WB-6-B

Wood BarrelTowers

NOTE: Faucet handles not included.

5400 North Michigan Road • Saginaw, MI • 48604-9780989.752.4275 • 800.748.0423 • Fax 989.752.4444 www.glastender.com Printed in USA

Dimensional InformationWood Barrel Tower

SIDE ELEVATION

FRONT ELEVATION

PLAN VIEW

18"

10-1/2"

18"

8-3/4"

9-1/2"

22-1/4"

21"

14"

22-1/4"

17-1/2"

29"

1/2" DRAIN

1-1/2"

5.07 - page 2

NOTE: Faucet handles not included.