BAT11B WLAN Overview
Wireless LAN AP (Access Point)or
Wireless LAN AC (Access Client)
RF Technology:•802.11b
Antenna Connection:•Two external RSMA antenna connections(For Diversity)
Range:•11mbp/s: 160m Outdoors, 30m Indoors, depending on antenna positioning
BAT11B WLAN Overview
Transmission speed:•11 Mbit/s (high) •5.5 Mbit/s (middle)•2 Mbit/s (standard)•1 Mbit/s (st. low speed)•Automatic Rate Selection (ARS)
Encryption:•No encryption•64 Bit (WEP)•128 Bit RC4 and WEP plus (weak key avoidance)
Frequency band:•2-4 to 2.4835 GHz (ISM band)•13 channels
Modulation:•Direct Sequence Spread Spectrum (DSSS) with CCK, DQPSK, DBPSK, CCK
Spreading:•11-chip Barker sequence
Delay spread (FER <1%):•11 Mbit/s: 65 ns•5.5 Mbit/s: 225 ns•2 Mbit/s: 400 ns•1 Mbit/s: 500 ns
BAT11B RF Module
Receiver sensitivity:•11 Mbit/s: -82 dB•5.5 Mbit/s: -87 dB•2 Mbit/s: -91 dB•1 Mbit/s: -94 dB
Bit error rate:•< 10-5
Transmitting power:•< 100 mW E.I.R.P. (ETSI); 15 dBm
Input voltage:•9 to 36 V
Power consumption:•Max. 500mA@9V
BAT11B RF Module
Media access protocol:•CSMA/CA with ACK
RF protocol:•IEEE 802.11b @ 11 Mbit/s and 5.5 Mbit/s,
IEEE 802.11 @ 2 Mbit/s and 1 Mbit/s
Topology:•Access point (infrastructure)•Access client (ad-hoc)
BAT11B Network
EMC interference immunity•EN 61000-4-2 Electrostatic discharge immunity test.•EN 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test•EN 61000-4-4 Electrical fast transient/burst •EN 61000-4-5 Surge immunity test•EN 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields
EMC radiated and conducted interference•EN 55022 class A
Approvals•As per R&TTE directive 1999/5/EC
Operating Temperature•-20 to +70 C
Humidity•0-95% non-condensing
BAT11B Environmental
LS1=Ethernet port 1&
LS2=Ethernet port 2 •Connected to LAN -> green
DA1=Data Transmission&
DA2=Data Transmission•Minor data received -> intermittent orange•Major data received -> constant orange
BAT11B Display & Operation 1
LS WAN •No AP/AC connection -> Intermittent Green•Valid AP/AC operation -> green•AP operation -> green
DA WAN•Minor data received -> blinks orange•Major data received -> solid orange
BAT11B Display & Operation 2
Management•BAT Discovery•Web Interface•SNMP-???
Diagnostics•LED’s•Signal Contact/Fault Relays
Configuration•BAT Discovery•Web Interface•DHCP
BAT11B Configuration
BAT11B Access Point Operation
Example 1 - the BAT in LAN 1 acts as an Access Point and the BAT in LAN 2 works as an Access Client. All clients in LAN 2 are connected to the AP in LAN 1.
BAT11B Infrastructure Operation
Example 2 – All clients communicate via the access point. However, all AC's have to be located within the range of the access point.
Example 2 – All clients communicate directly with each other. However, this method is not optimal as interference can occur with more regularity.
BAT11B Ad-Hoc Operation
BAT11B – BAT Discovery Protocol
Rail Power Supply RPS60Product features
Power Supply
-For 24V DC (2.5A) power supply(RPS60) - For 24V DC (5A) power supply(RPS120) - Input voltage ranges: 115/230V AC
160/375V DC
-Quick assembly on a standard DIN rail
- Operating temperature -100C to+600C
diverse applications
-Parallel connection ensures high availability
Of the power supply