Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
1
2
Basic Automation a BRISK group company is one of the
fastest growing solution providers of Industrial Interfacing
and Automation solutions in the country today. Our mission
is to provide swift, reliable and complete customer service
and support.
In our aim to be the complete and leading solution
provider of Industrial and Interfacing Automation
we look to our founding principles and continue to
build upon them.
In all our work we adhere to highest professional
standards and by imposing these high standards
we have earned trust and confidence of our
customers.
PrinciPles
HigH standards and etHics
tecHnical innovation and dynamic growtH
meeting and surPassing customer needs and exPectations
Accompanied by growth Basic automation has
more then kept pace with the technological
change in the industry and we will keep doing so
in the coming years.
We believe that if we deliver products of quality
beyond customer’s expectations, customers
will return again and again, asking us to further
contribute to their success.
Interfacing Redefined...
B A S I CAUTOMATION
measuring & monitoring relays 3
relay interFace moduleBasic automation offers a wide range of interfacing
modules used for control process. Whether it is just
a small system with few I/O signals or a complex
power station that is being put into operation, what
they all have in common is that the signals from
the automation device must be connected to the
field level in an industry. The range offers Standard
Cards, PLC/DCS specific cards, CNC Specific Cards,
Genset Cards, Panel accessory cards, Passive cards
and various Customised solutions.
signal isolators & convertersBasic automation offers modular converters for
measuring and control technology to avoid distortion
of analog signals caused by external interference.
With accurate conversions, electrical isolation or
adaptation of analog signals, they provide safe and
increased transmission quality and thus quality
of control circuits. The range includes isolators
and converters for Voltage, Current, Temperature,
Frequency and Resistance thermometers.
By following cutting edge solutions, products of highest calibre and above
all our extensive marketing network and dedicated employees, has resulted
in our meeting complex needs of the most demanding users and propelled
Basic Automation to be the preferred supplier of Interfacing products
CERTI
FIED
QUA
L ITY MANAGEMENT SYSTEM
ISO
9001 : 2
000
measuring & monitoring relays4
measuring & monitoring relaysBasic automation offers a fully coordinated
range of automation components for monitoring
applications. A variety of designs with different
functionalities is available from monitoring of
Current, Voltage, Frequency and Phase. The Swift
series precisely capture various characteristics
and consequently enhance the availability and
reliability of plants, buildings and machines.
They monitor and control wide variety of
different processes in different Industries. By
exact recognition of characteristics generate a
consistent added value.
analog timersBasic automation offers timers ranging from single-
function to multi-function timer with display,
are employed in all branches of industry. The
brain chip of your application-specific miniature
controller is the ideal solution for realizing custom
control applications within minimum space at low
cost.
our tecHnology Partners
measuring & monitoring relays 5
6-8 Voltage Monitoring Relays Phase Monitoring Relays 6
Voltage Monitoring Relays 7
Voltage Monitoring Relays Malfunction 8
9-10 Current Monitoring Relays Current Monitoring Relays 9
Current Monitoring Relays Malfunction 10
11-12 Frequency Monitoring Relays Frequency Monitoring Relays 11
Frequency Monitoring Relays Malfunction 12
13-14 Reverse Power Monitoring Relays Reverse Power Monitoring Relays 13
Reverse Power Monitoring Relays Malfunction 14
contents
measuring & monitoring relays6
aPPlicationIt is a Negative Sequence Voltage Sensing Phase Failure Relay. It is best suitable for 3 phase loads or
3 phase motor / pump loads only. It offers protection against Phase Failure, Phase Unbalance, Phase
Sequence Reversal, Under Voltage & Over Voltage faults. It is useful for incoming side, Mains Supply
monitoring, General voltage faults, AMF/Transfer Switch Panels & Pump Control
Phase Monitoring RelaysB A S I CAUTOMATION
Function Part numBer
Phase-Failure, Sequence,UnbalancReversal,. UV/OV Adj, Trip time Adj.
SP-FUSOV-1P-2
SP-FUSOV-3P-2
SP-FUSOV-3P-2-D
SP-FUSOV-1P-2-D
SP-FUSOV(TD)-3P-2
ordering inFo
range Features
Phase Failure, Phase Sequence, Phase Output Relay 10A@230AC
Unbalance, Phase Reversal, Phase Loss 5A@230AC
Under-Over Voltage Adjustable Adj. Settings: Thru Knobs
Voltage Selection Thru Jumpers
tecHnical data: general data
Output Contacts Optional 1C/o or 2C/o Supply Voltage System 110/240/380/415 +/-
20%,50-60Hztrip settings
Phase Sequence Yes Auxilliary 110/240/380/415 +/- 20%,Phase Unbalance 4% to 20% Variable Mechanical Size 45 X 75 X 110 UV/OV Variable (85%U & 110%O) Enclosure ABS Plastic , 35 mmtrip time delay Operating Temp. 0 – 55 Deg. C On Phase Sequence Instant Protection Level IP 20
On SP/UV/OV 1 to 10 Sec Variable (>2Sec) Mounting Din Rail
Resetting Mode Optional Auto/Remote/Manual display: model witH disPlay
standards & aPProval
*PCB: Type tested STQC, IEC 61373,
*ANSI IPC 319 MIL 275B
*Terminals: UL/CE & CSA
measuring & monitoring relays 7
aPPlicationIt is a Negative Sequence Voltage Sensing Phase Failure Relay. It is best suitable for 3 phase loads or
3 phase motor / pump loads only. It offers protection against Phase Failure, Phase Unbalance, Phase
Sequence Reversal, Under Voltage & Over Voltage faults. It is useful for incoming side, Mains Supply
monitoring, General voltage faults, AMF/Transfer Switch Panels & Pump Control
Voltage Monitoring RelaysB A S I CAUTOMATION
Function Part numBer
Voltage- Under, Adj. Trip Delay and On Delay Adj. 1 Phase and 3 Phase
SV-U(TDOD)-1P-1
SV-U(TDOD)-3P-1
ordering inFo
range Features
1 Phase Under & Over Voltage, Output Relay 5A @ 230AC
Trip Delay, ON Delay Adjustable
Adj. Settings: Thru Knobs
Voltage Selection Thru Jumpers
tecHnical data: general data
Output Contacts Optional 1C/o or 2C/o Supply Voltage System 110/240/380/415 +/-
20%,50-60Hz trip settings
Under Voltage 75% - 90% - Fixed Auxilliary 110/240/380/415 +/- 20%,Over Voltage N.A Mechanical Size 23 X 75 X 110
Enclosure ABS Plastic , 35 mmtrip time delay 1-10 Sec Adj or Fixed Operating Temp. 0 – 55 Deg. C Power On Delay 1-10 Sec Adj or Fixed Protection Level IP 20 Resetting Mode Auto Mounting Din Rail
standards & aPProval
*PCB: Type tested STQC, IEC 61373, *Ambient Opt Temp: Max 60 Deg.C
*ANSI IPC 319 MIL 275B *Relative Humidity: Max 90% (Non-Condensing)
*Terminals: UL/CE & CSA *Enclosure : CE, UL Approved
Sw
ift S
erie
s -
Vol
tage
Mon
itorin
g R
elay
s
measuring & monitoring relays8
aPPlicationIt is a 1 OR 3 Phase Voltage Monitoring Relay. It is best suitable for monitoring1 phase 2 wire loads powered by Single Phase Generators, Stabilizers, Inverters or Electricity Board (Utility). It is used to protect against fluctuating voltage to start standby generators, to operate mains failure units, Gensets, AMF Panels, PCC, Distribution boards and similar applications, where close regulation is required. Some of the other added advantages are easy & quick settings from front. User friendly indications. DIN-Rail mounting and Panel mounting facility.
Voltage Monitoring Relays MultifunctionB A S I CAUTOMATION
Function Part numBer
Voltage- Under, Over Adj. Trip Delay and On Delay Adj. 1 Phase and 3 Phase
SV-UO(TDOD)-1P-2
SV-UO(TDOD)-3P-2
3W SV-UO(TDOD)-3W-3P-2
4W SV-UO(TDOD)-4W-3P-2
ordering inFo
range Features
1 - 3 Phase Under & Over Voltage, Output Relay 5A@230AC
Trip Delay, ON Delay Adjustable
3 Wire and 4 Wire Systems Adj. Settings: Thru Knobs
Voltage Selection Thru Jumpers
tecHnical data: general data
Output Contacts Optional 2C/o Supply Voltage System 110/240/380/415 +/-
20%,50-60Hztrip settings
Under Voltage 75% - 90% - Variable Auxilliary 110/240/380/415 +/- 20%,Over Voltage 105% - 120% - Variable Mechanical Size 23 X 75 X 110
Enclosure ABS Plastic , 35 mmtrip time delay 1-10 Sec Adjustable Operating Temp. 0 – 55 Deg. C Power On Delay 1-10 Sec Adjustable Protection Level IP 20 Resetting Mode Optional Auto/Remote/Manual Mounting Din Rail
standards & aPProval
*PCB: Type tested STQC, IEC 61373, *Ambient Opt Temp: Max 60 Deg.C
*ANSI IPC 319 MIL 275B *Relative Humidity: Max 90% (Non-Condensing)
*Terminals: UL/CE & CSA *Enclosure : CE, UL Approved
measuring & monitoring relays 9
aPPlicationMeasures 1 phase current through 1 A or 5A external current transformer(CT) & monitors under & over
current conditions. It energizes with time delay and trips with time delay under above conditions.
Current Monitoring RelaysB A S I CAUTOMATION
Function Part numBer
Current- Over, Adj. Trip Delay Adj. 1 Phase
SC-U(TD)-1P-1
ordering inFo
range Features
1 Phase Under Current, Output Relay 5A @ 230AC
Trip Delay, ON Delay Adjustable
Input 1A or 5A through CT Adj. Settings: Thru Knobs
Voltage Selection Thru Jumpers
tecHnical data: general data
Output Contacts 1C/o Supply Voltage Auxilliary 110/240/380/415 +/- 20%,50-60Hz
trip settings Ext. Input 1Amp or 5 Amp (Secondary) CT
Under Voltage Mechanical Size 23 X 75 X 110
Over Voltage 50% - 140% Enclosure ABS Plastic , 35 mm
Operating Temp. 0 – 55 Deg. C
trip time delay 1-10 Sec Adj or Fixed Protection Level IP 20
Power On Delay 3.5 secs +/-1.5 sec(Fixed) Mounting Din Rail
Resetting Mode Auto
standards & aPProval
*PCB: Type tested STQC, IEC 61373, *Ambient Opt Temp: Max 60 Deg.C
*ANSI IPC 319 MIL 275B *Relative Humidity: Max 90% (Non-Condensing)
*Terminals: UL/CE & CSA *Enclosure : CE, UL Approved
Sw
ift S
erie
s -
Cur
rent
Mon
itorin
g R
elay
s
measuring & monitoring relays10
aPPlicationMeasures 1 phase current through 1 A or 5A external current transformer(CT) & monitors under & over
current conditions. It energizes with time delay and trips with time delay under above conditions
Current Monitoring Relays MultifunctionB A S I CAUTOMATION
Function Part numBer
Current- Under, Over Adj. Trip Delay and On Delay Adj. 1 Phase
SC-UO(TDOD)-1P-2
SC-UO(TDOD)-3P-2
ordering inFo
range Features
1 Phase Under & Over Current, Output Relay 5A@230AC (resistive)
Trip Delay, ON Delay Adjustable 5A@230AC
Input 1A or 5A through CT Adj. Settings: Thru Knobs
Voltage Selection Thru Jumpers
tecHnical data: general data
Output Contacts 2C/o Supply Voltage Auxilliary 110/240/380/415 +/-
20%,50-60HzTrip Settings Ext. Input 1Amp or 5 Amp (Selectable) CT
Under Voltage 10% - 100% Adjustable Mechanical Size 45 X 75 X 110
Over Voltage 50% - 140% Adjustable of CT Enclosure ABS Plastic , 35 mm
Operating Temp. 0 – 55 Deg. C
Trip Time Delay 1-10 Sec Adjustable Protection Level IP 20
Power On Delay 1-10 Sec Adjustable Mounting Din Rail
Resetting Mode Auto
standards & aPProval
*PCB: Type tested STQC, IEC 61373, *Ambient Opt Temp: Max 60 Deg.C
*ANSI IPC 319 MIL 275B *Relative Humidity: Max 90% (Non-Condensing)
*Terminals: UL/CE & CSA *Enclosure : CE, UL Approved
measuring & monitoring relays 11
Current Monitoring Relays Multifunction
aPPlicationIt is a Over Frequency Relay. It is best suitable for monitoring supply over frequency or generator over speed. It is used in single phase system supply, where Over Frequency monitoring or protection is required. It can be Rail mounted & have individually settable over frequency settings, thus increasing their utility as entire System Protection Relays. Added facility of adjustable Trip Time Delay and Power-ON Delay has also be provided, alongwith separate indications. It can be used as over speed monitor of DG sets.
Fequency Monitoring RelaysB A S I CAUTOMATION
Function Part numBer
Frequency- Over, Adj. Trip Delay Adj. 1 Phase
SF-O(TD)-1P-1
ordering inFo
range Features
1 Phase Over Frequency, Output Relay 5A @ 230AC
Trip Delay, Over Frequency Adjustable
Adj. Settings: Thru Knobs
Voltage Selection Thru Jumpers
tecHnical data: general data
Output Contacts 2C/o Supply Voltage System 110/240/380/415 +/-
20%,50-60Hz trip settings
Under Frequency Auxilliary 12 / 24 VDC or Built in
Over Frequency 50 Hz - 70 Hz Mechanical Size 23 X 75 X 110
Enclosure ABS Plastic , 35 mmtrip time delay 1-10 Sec Adj or Fixed Operating Temp. 0 – 55 Deg. C Power On Delay 3.5 secs +/-1.5 sec(Fixed) Protection Level IP 20 Resetting Mode Auto Mounting Din Rail
display: model witH disPlay
standards & aPProval
*PCB: Type tested STQC, IEC 61373, *Ambient Opt Temp: Max 60 Deg.C
*ANSI IPC 319 MIL 275B *Relative Humidity: Max 90% (Non-Condensing)
*Terminals: UL/CE & CSA *Enclosure : CE, UL Approved
Sw
ift S
erie
s -
Fre
quen
cy M
onito
ring
Rel
ays
measuring & monitoring relays12
aPPlicationIt is a Over Frequency Relay. It is best suitable for monitoring supply over frequency or generator over speed. It is used in single phase system supply, where Over Frequency monitoring or protection is required. It can be Rail mounted & have individually settable over frequency settings, thus increasing their utility as entire System Protection Relays. Added facility of adjustable Trip Time Delay and Power-ON Delay has also be provided, alongwith separate indications. It can be used as over speed monitor of DG sets
Frequency Monitoring Relays MultifunctionB A S I CAUTOMATION
Function Part numBer
Frequency- Under, Over Adj. Trip Delay and On Delay Adj. 1 Phase
SF-UO(TDOD)-1P-2
SF-UO(TDOD)-3P-2
ordering inFo
range Features
1 Phase Under & Over Frequency, Output Relay 5A@230AC (resistive)
Trip Delay, ON Delay Adjustable 5A@230AC
Input 1A or 5A through CT Adj. Settings: Thru Knobs
Voltage Selection Thru Jumpers
tecHnical data: general data
Output Contacts 2C/o Supply Voltage System 110/240/380/415 +/-
20%,50-60HzTrip Settings Auxiliary Built In
Under Voltage 40 Hz - 60 Hz (Variable) Mechanical Size 45 X 75 X 110
Over Voltage 50 Hz - 70 Hz (Variable) Enclosure ABS Plastic , 35 mm
Operating Temp. 0 – 55 Deg. C
Trip Time Delay 1-10 Sec Adjustable Protection Level IP 20
Power On Delay 1-10 Sec Adjustable Mounting Din Rail
Resetting Mode Auto
standards & aPProval
*PCB: Type tested STQC, IEC 61373, *Ambient Opt Temp: Max 60 Deg.C
*ANSI IPC 319 MIL 275B *Relative Humidity: Max 90% (Non-Condensing)
*Terminals: UL/CE & CSA *Enclosure : CE, UL Approved
measuring & monitoring relays 13
Frequency Monitoring Relays Multifunction
aPPlicationIt is a 3 Phase 4 Wire Reverse Power Relay. It is best suitable for monitoring the reverse flow of power from the 1 Phase or 3 Phase Generators or Emergency Power Supplies or when motors act as Generators. It senses the direction of power (current) by sensing the reverse Current. The power is calculated as V x I (Reverse Current) x COS f. It is measured by considering 5 Amps as the maximum Reverse Current for 100% Reverse Power. It can be preset from 2% - 20% reverse power. If the current from the Generator becomes reversed and it exceed the setting then the relay trips.
Reverse Power Monitoring RelaysB A S I CAUTOMATION
Function Part numBer
Revrse Power- Adj. Trip Delay and On Delay Adj. 3 Phase, 3 Wire or 4 Wire
SP-R(TDOD)3W-3P-2
SP-R(TDOD)4W-3P-2
ordering inFo
range Features
3 Phase Generator Reverse Power Monitoring, Output Relay 5A @ 230AC
Trip Delay, ON Delay Adjustable
3 Wire - 4 Wire Selectable Adj. Settings: Thru Knobs
Voltage Selection Thru Jumpers
tecHnical data: general data
Output Contacts 2C/o System 3P-3W/4W-
110/240/380/415trip settings Auxilliary Built in
Reverse Power 2% - 20% - (Adjustable) Ext. Input 5A, CT & R,Y,B
Mechanical Size 45 X 75 X 110
Enclosure ABS Plastic , 35 mmtrip time delay 1-10 Sec Adj or Fixed Operating Temp. 0 – 55 Deg. C Power On Delay 1-10 Sec Adjustable or Fixed Protection Level IP 20 Resetting Mode Auto Mounting Din Rail
standards & aPProval
*PCB: Type tested STQC, IEC 61373, *Ambient Opt Temp: Max 60 Deg.C
*ANSI IPC 319 MIL 275B *Relative Humidity: Max 90% (Non-Condensing)
*Terminals: UL/CE & CSA *Enclosure : CE, UL Approved
Sw
ift S
erie
s -
Rev
erse
Pow
er M
onito
ring
Rel
ays
measuring & monitoring relays14
aPPlicationIt is a 3 Phase 4 Wire Reverse Power Relay. It is best suitable for monitoring the reverse flow of power from the 1 Phase or 3 Phase Generators or Emergency Power Supplies or when motors act as Generators. It senses the direction of power (current) by sensing the reverse Current. The power is calculated as V x I (Reverse Current) x COS f. It is measured by considering 5 Amps as the maximum Reverse Current for 100% Reverse Power. It can be preset from 2% - 20% reverse power. If the current from the Generator becomes reversed and it exceed the setting then the relay trips.
Reverse Power Monitoring Relays Multifunction
B A S I CAUTOMATION
Function Part numBer
Revrse Power- Adj. Under
and Over,Trip Delay and On
Delay Adj. 3 Phase, 3 Wire
SP-UO(TDOD)3W-3P-2
ordering inFo
range Features
3 Phase Generator Reverse Power Monitoring, Output Relay 5A@230AC (resistive)
Trip Delay, ON Delay Adjustable 5A@230AC
3 Wire - 4 Wire Selectable Adj. Settings: Thru Knobs
Voltage Selection Thru Jumpers
tecHnical data: general data
Output Contacts 1C/o + 1C/o System 3P-3W-110/240/380/415 Trip Settings Auxiliary Built In
Under Power 10% - 100% - (Adjustable) Ext. Input PTS D1(1A/5A, CT 3P)
Over Power 10% - 100% - (Adjustable) Mechanical Size 45 X 75 X 110
Enclosure ABS Plastic , 35 mmTrip Time Delay 1-10 Sec Adjustable Fixed Protection Level IP 20
Power On Delay 1-10 Sec Adjustable Fixed Mounting Din Rail
Resetting Mode Auto/Manual
standards & aPProval
*PCB: Type tested STQC, IEC 61373, *Ambient Opt Temp: Max 60 Deg.C
*ANSI IPC 319 MIL 275B *Relative Humidity: Max 90% (Non-Condensing)
*Terminals: UL/CE & CSA *Enclosure : CE, UL Approved
15
Reverse Power Monitoring Relays Multifunction
NOTES
B A S I CAUTOMATION
measuring & monitoring relays16