1
Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference Leaflet No. 234527~A 10 mm 8 mm 3 mm In masonry, drill 8mm diameter holes and insert the plugs provided. In timber, drill 3mm diameter pilot holes. Leave the screws protruding Flush the water supply line. Make sure that the strainer is in place. Then fit the water supply pipe using approved fittings. Turn on the water. Operate the cistern and check for leaks. Carefully refit the lid. Actuate the Inlet valve at least once to purge any trapped air in the valve. Adjust the water level to the WL2 mark. 20 mm 53 mm Kee seal Cut the flushpipe to dimensions shown. Lubricate the kee seal with soap and water and fit the Lower the cistern onto the pipe and hook it over the mounting screws. Nip up the mounting screws. Hand tighten the nut. When installing low level use L-shaped pipe only. For mid level fit the seal and lubricate it with soap and water. Push firmly into the shorter leg of the flush pipe. 168 mm 240 mm Correct fitting of Seal NOTE: Do Not use extension horizontally Check that the pan is installed within dimensional tolerances. Mark out the fixing holes for the cistern on the wall making sure they are level. 400 mm Reference 105 mm 50 - 260 mm to suit tiling Top of Pan 775 mm Fixing Holes (Mid Level) 365 mm Fixing Holes 190 - 330 mm 165 mm - Recommended 445 mm Fixing Holes (Low Level) Adjustment Screw BASE Mid/Low Level Cistern Only 4.5/3L White (4*) Installation Instructions Page 1 of 1

Base - 4.5/3L ML-LL Dual Flush Cistern 234027 BASE Mid/Low Level Cistern Only 4… · 4. Slide inner assembly back into cistern ensuring the the dovetail guides at the rear line up

  • Upload
    others

  • View
    12

  • Download
    0

Embed Size (px)

Citation preview

  • Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

    Base - 4.5/3L ML-LL Dual Flush Cistern

    Procedure for converting to 6/3 or 9/4.5L flush

    Manufactured in Australia and Distributed byCaroma Industries Limited.ABN 35 000 189 499Locked Bag 20, Epping, NSW 2121

    Lea�et No. 234527~A

    234027

    418

    423

    164

    1. Turn off water supply. Pull both clips on front of cistern back to release Bridge mechanism.

    3(1). - Conversion to 6/3LPull out wrap around bucket in the middle by spreading the ends apart and twisting.

    2. Remove inner outlet valve assembly from the cistern by pulling upwards.

    3(2). - Conversion to 9/4.5LPull out both of the lower 2 wrap around buckets by spreading the ends apart and twisting.

    4. Slide inner assembly back into cistern ensuring the the dovetail guides at the rear line up and the dovetail guides at the front clip into place. Turn on water supply and check water level.

    This cistern is factory set at 4.5 / 3L and can be adjusted to 6 / 3L or 9 / 4.5L as detailed below

    Reece Code: 9502717 BASE ML/LL Cistern 4.5 / 3L (ADJ) WH (4*)

    10 mm

    8 mm

    3 mm

    In masonry, drill 8mm diameter holes and insert the plugs provided. In timber, drill 3mm diameter pilot holes.Leave the screws protruding

    Flush the water supply line.

    Make sure that the strainer is in place. Then fit the water supply pipe using approved fittings.

    Turn on the water. Operate the cistern and check for leaks.

    Carefully refit the lid.Actuate the Inlet valve at least once to purge any trapped air in the valve.Adjust the water level to the WL2 mark.

    20 mm

    53 mm

    Kee seal

    Cut the flushpipe to dimensions shown. Lubricate the kee seal with soap and water and fit the

    Lower the cistern onto the pipe and hook it over the mounting screws.

    Nip up the mounting screws.Hand tighten the nut.

    When installing low level use L-shaped pipe only. For mid level fit the seal and lubricate it with soap and water. Push firmly into the shorter leg of the flush pipe.

    168mm

    240 mm

    Correct fitting of SealNOTE: Do Not use extension horizontally

    Check that the pan is installed within dimensional tolerances. Mark out the fixing holes for the cistern on the wall making sure they are level.

    400 mm Reference

    105 mm

    50 - 260 mm to suit tiling

    Top of Pan

    775 mm Fixing Holes (Mid Level)

    365 mm Fixing Holes

    190 - 330 mm

    165 mm - Recommended

    445 mm Fixing Holes (Low Level)

    Adjustment Screw

    I n s t a l l a t i o n I n s t r u c t i o n sBASE Mid/Low Level Cistern Only 4.5/3L White (4*)

    Installation Instructions

    Page 1 of 1