Warsaw, September 1-4, 2008
TECHNICALTECHNICAL PARAMETERSPARAMETERSAnti-proliferative agentAnti-proliferative agent paclitaxel (ca. 1paclitaxel (ca. 1µµg/mmg/mm22))
PolymerPolymer BiodegradableBiodegradable
Stent diameterStent diameter 2.25 – 5.00 mm2.25 – 5.00 mm
Stent lengthStent length (mm) (mm) 8, 10, 12, 18, 10, 12, 155, 18, 2, 18, 222, 2, 25, 29, 345, 29, 34
Stent platformStent platform stainless steel 316Lstainless steel 316L
Strut thicknessStrut thickness 0.12mm0.12mm
DesignDesign closed cell - closed cell - for uniform drug distribution and for uniform drug distribution and coverage of the vessel wall coverage of the vessel wall
FerromagnetismFerromagnetism nonenone
MRIMRI safesafe
Use with guide wireUse with guide wire max max .014”.014”
Use with guiding catheterUse with guiding catheter 5F5F**
Length reduction after deploymentLength reduction after deployment <<00.5.5%%
Recoil Recoil <2%<2%
Stent crimped profileStent crimped profile .0.04040” (for stent diameter 3mm)” (for stent diameter 3mm)
Distal shaft diameterDistal shaft diameter 2.7F/0.90 mm2.7F/0.90 mm
Proximal shaft diameter Proximal shaft diameter 2F/0.65 mm2F/0.65 mm
Nominal pressureNominal pressure / RBP / RBP 10 10 atm / 16 atmatm / 16 atm
* * (for stent diameter(for stent diameter 4.54.5 and and 5.0 mm 5.0 mm use guiding catheter use guiding catheter 6F6F))Warsaw, September 1-4, 2008
DEGRADATION OF TESTED POLYMERDEGRADATION OF TESTED POLYMER
The surface of the stent after 1 week
The surface after 8 weeks
Residual polymer left on the stent surface after 8 weeks
The samples of stents covered with tested polymer and removed from isotonic salt solution at different time points
Warsaw, September 1-4, 2008
EXCELLENT CEXCELLENT COATING OATING IINTEGRITYNTEGRITY OF LUC-CHOPINOF LUC-CHOPIN22 STENT STENT
Warsaw, September 1-4, 2008
COMPETITORCOMPETITOR SIROLIMUSSIROLIMUS ELUTINGELUTING STENTSTENT
Warsaw, September 1-4, 2008
Warsaw, September 1-4, 2008
- WCC Barcelona 2006, - TCT 2005, 2006, 2008 Washington- ESC Vienna, 2007- International LDDR meeting, Geneva 2006, 2008- Interventional cardiology meeting, Snowmass 2008
LIST OF ABSTRACTS PRESTENTED LIST OF ABSTRACTS PRESTENTED AT INTERNATIONAL CONGRESSESAT INTERNATIONAL CONGRESSES
1st prize for Balton!
Warsaw, September 1-4, 2008
Warsaw, September 1-4, 2008
Technical parameters of stentTechnical parameters of stent
MaterialMaterial steel 316 Lsteel 316 L
DesignDesign closed cellclosed cell
Strut thicknessStrut thickness 0.12 mm0.12 mm
Stent diameterStent diameter 2.25 – 5.00 mm2.25 – 5.00 mm
Stent lengthStent length 8, 10, 12, 18, 10, 12, 155, 18, 2, 18, 222, 2, 25, 29, 345, 29, 34 mm mm
MRIMRI safesafe
Use with guide wireUse with guide wire .014”.014”
Use with guiding catheterUse with guiding catheter 5F *5F *
Length reduction after Length reduction after deploymentdeployment <<00.5.5%%
Recoil Recoil <2%<2%
Stent crimped profileStent crimped profile .038”/0.97 mm .038”/0.97 mm (for stent diameter 3mm)(for stent diameter 3mm)
Distal shaft diameterDistal shaft diameter 2.7F/0.90 mm2.7F/0.90 mm
Proximal shaft diameter Proximal shaft diameter 2F/0.65 mm2F/0.65 mm
Nominal pressureNominal pressure/RBP/RBP 10 10 atm/16atmatm/16atm
ChopinChopin2 2 TMTM - STENT FOR CORONARY ARTERIES - STENT FOR CORONARY ARTERIESWITH DELIVERY SYSTEMWITH DELIVERY SYSTEM
* * (for stent diameter(for stent diameter 4.54.5 and and 5.0 mm 5.0 mm use guiding catheter use guiding catheter 6F6F))
Warsaw, September 1-4, 2008
Events n=97
Death 0 (0%)
Myocardial infarction:-Q wave-- non-Q wave
0 (0%)
0 (0%)
Emergent CABG 2 (1.9%)
TLR* 22 (22.6%)
Revascularization per patient 0.24
Cumulative MACE 24 (24.7%)
Late thrombosis 0 (0%)
ChopinChopin22 STENT REGISTRY STENT REGISTRY - CLINICAL OUTCOMES AFTER 6 MONTHS- CLINICAL OUTCOMES AFTER 6 MONTHS
*clinically driven
Warsaw, September 1-4, 2008
Warsaw, September 1-4, 2008
They feature high functional parameters quality:- Thin walls, allowing maximum flow.- High pressure resistant 100 atm (1450PSI).- Relevant softness, flexibility and curvature, facilitating
catheter introduction and advancement.- Good visibility in X-rays.- Perfectly smooth surface and very good finishing of
side holes.- Tip atraumatic for the vessels.
Each catheters features a Luer-Lock connector, making the set hermetic.
Some catheters size 5F and 6F are available in reinforced configuration with stainless steel braided.
All catheters feature the same softness in distal parts (unbraided).
CATHETERS FOR ANGIOGRAPHYCATHETERS FOR ANGIOGRAPHYCATHETERS FOR ANGIOGRAPHYCATHETERS FOR ANGIOGRAPHY
Warsaw, September 1-4, 2008
CARDIOLOGICALCARDIOLOGICAL INTRODUCERINTRODUCER
Radiological introducer
Radial artery cardiological introducer
Warsaw, September 1-4, 2008
GUIDEWIRESGUIDEWIRESGUIDEWIRESGUIDEWIRES
For interventional cardiology & radiology The tip of the guidewire is appropriately shaped andatraumatic for optimal patient's security Designed for complex vascular interventions including"cross-over" techniques.
Guidewires Size
Steel guidewires .022”, .035”, .038”
Hydrophilic guidewires .032”, .035”, .038”
Micro guidewires .007”, .009”, .014”
Lunderquist guidewires .035”
PTFE coated guidewires .018”, .022”, .025”, .035”, .038”
PTCA guidewire „Rider” .014”
Warsaw, September 1-4, 2008
PTCA GPTCA GUIDEUIDE WIRESWIRES „RIDER” – WITH „RIDER” – WITH HYDROPHILIC COATINGHYDROPHILIC COATINGPTCA GPTCA GUIDEUIDE WIRESWIRES „RIDER” – WITH „RIDER” – WITH HYDROPHILIC COATINGHYDROPHILIC COATING
Guidewire Size Length Type
PTCA guidewires
.014” 175 – 300 cm„J”
Straight
PTCA guide wires technical data:PTCA guide wires technical data:
•Material: steel and platinum•Length 175 -300 cm•Broad range of stiffness•Radiopaque marker of min. 25 mm length•Straight and "J" shaped guide wire tips•Excellent steerability•Special coating for optimal crossing of tortuous and narrow vessels•Stiff proximal shaft•Good visibility of guide wire tip•Optimal torque control 1:1
The guide wires are available in several kinds of flexibility of the distal tip:
•with high floppy tip – HF•with floppy tip - F, •with medium tip - M, •with stiff tip – S•with high stiff tip – HS
Guide wires are available with additional strengthening in their proximal spiral part, which enables their for the delivery of stents:
•stent support floppy – STF•stent support medium – STM•stent support stiff – STS.
Warsaw, September 1-4, 2008
PERIPHERAL ANGIOPLASTY CATHETERPERIPHERAL ANGIOPLASTY CATHETER PBA PBAPERIPHERAL ANGIOPLASTY CATHETERPERIPHERAL ANGIOPLASTY CATHETER PBA PBA
Balloon diameter 4 - 12 mm
Balloon length 20 - 100 mm
Use with introducer For balloon diameter 4 – 7 mm 6F
Use with introducer For balloon diameter 8 – 10 mm 7F
Use with introducer For balloon diameter 12 mm 8F
Nominal pressure 6 atm
Rated Burst Pressure
RBP10 atm
Catheter length 80 or 110 cm
Type of delivery system
OTW
Warsaw, September 1-4, 2008
Balloon diameter 1.5 – 5.0 mm
Balloon length 10 - 40 mm
Use with guiding catheter
For balloon diameter 1.5 – 4.0mm 5F
Use with guiding catheter
For balloon diameter 4.5 – 5.0mm 6F
Nominal pressure 10 atm
Rated Burst Pressure
RBP16 atm
Catheter length 140 cm
Type of delivery system RX
CORONARYCORONARY ANGIOPLASTYANGIOPLASTY CATHETERCATHETERCORONARYCORONARY ANGIOPLASTYANGIOPLASTY CATHETERCATHETER
NEWNEW VERSIONVERSIONNEWNEW VERSIONVERSION
Warsaw, September 1-4, 2008
NefroNefroTMTM - STENT FOR RENAL ARTERIES - STENT FOR RENAL ARTERIESWITH DELIVERY SYSTEM - Rapid Exchange WITH DELIVERY SYSTEM - Rapid Exchange (RX)(RX)
Material 316 stainless steel
Guide wire Max .014”
Guiding catheter 6F
Nominal pressure 8 atm
Rated burst pressure 12 atm
Available diameters 5.0 – 7.0mm
Lengths 8.0 – 22.0mm
Warsaw, September 1-4, 2008
NeptunNeptunTMTM - STENT FOR PERIPHERAL - STENT FOR PERIPHERAL VESSELS WITH DELIVERY SYSTEMVESSELS WITH DELIVERY SYSTEM
Stent diameterStent diameter 4 - 10 mm4 - 10 mm
Stent lengthStent length 16 - 100 mm16 - 100 mm
Use with guide Use with guide wirewire .035”.035”
Use with Use with introducerintroducer for stent diameter 4 – for stent diameter 4 – 66 mm mm 6F6F
Use with Use with introducerintroducer for stent diameter for stent diameter 77 – 9 mm – 9 mm 7F7F
Use with Use with introducerintroducer for stent diameter 10 mmfor stent diameter 10 mm 8F8F
Nominal PressureNominal Pressure 6 6 atmatm
Rated Burst Rated Burst PressurePressure 10 10 atmatm
Catheter lengthCatheter length 80 or 110 cm80 or 110 cm
Delivery system Delivery system typetype OTWOTW
Warsaw, September 1-4, 2008
JaguarJaguarTMTM -SELF EXPANDING NITINOL -SELF EXPANDING NITINOL STENT WITH DELIVERY SYSTEMSTENT WITH DELIVERY SYSTEM
Material Nitinol wire with platinum markers
Available diameters 4.0 – 10.0 mm
Lengths 15.0 – 120.0 mm
The JaguarSM self-expanding stent with a delivery system is recommended for percutaneous intravascular deployment in patients with atherosclerotic, radiation and trauma-induced stenoses.
The soft and rounded tip of delivery system is atraumatic towards the arterial wall.
Special construction of delivery system enable to correction of stent position inside a vessel even after the partial stent release
Warsaw, September 1-4, 2008
TTrachearacheall and esophag and esophageal stent - TOReal stent - TORTracheal and esophageal Tor stent is made of nitinol, which is material of high biocompatibility.Tor stent with the delivery system provides high efficiency and comfort of application during an attempt to restore patency of highly stenotic trachea, bronchi or esophagus.Thanks to its perfect elasticity the stent perfectly matches the shape of the trachea and esophagus.A special construction of the stent protects against migration.The delivery system is characterised by high elasticity.Atraumatic endings of the system minimise the risk of damage during the procedure.
TECHNICAL INFORMATION:
Stent made of nitinol Diameter of stent: 15 - 30 mm Length of stent: 20 – 80 mm Very high radial force of the stent Rounded endings of the stent which efficiently
protect the walls of the trachea and esophagus against damage
Very good stent radiopacity – platinum markers on the stent endings which allow for precise implantation
Atraumatic ending of the delivery system Size of the delivery system: 14F Length of delivery system: 50, 60, 70 cm TORTOR
Warsaw, September 1-4, 2008
Large vessel catheterization set with:- Single lumen catheter- Double lumen catheter- Triple lumen catheter- Four lumen catheter
Anaesthesia sets
Warsaw, September 1-4, 2008
Thermodilution set “BALKAT”
Spinal anaesthesia needles
Warsaw, September 1-4, 2008
Dialysis sets
Hemodialysis needles
Warsaw, September 1-4, 2008
Embolectomy catheters
Aortic catheters
Catheter for bile duct’s
Drains
Warsaw, September 1-4, 2008
- Nephrostomy sets
Nephrostomy & cystostomy set
- Cystostomy sets
- Ureteral catheters
- Sets for stent introduction
Warsaw, September 1-4, 2008
Insemination catheters
Histerosalpingography sets
HSG catheters
Warsaw, September 1-4, 2008