Upload
letram
View
219
Download
2
Embed Size (px)
Citation preview
7-106 www.norgren.com/info/en7-106
For further information
Ideally suited for most industrialapplications
Easy installation, simpleoperation and maintenance free
Full bore passage givingminimum flow resistance
3-way ball valves with surfaceconforms to ISO 5211 for rotaryactuators
TECHNICAL DATAMedium:
Compressed air, water, inertgases and any other fluidcompatible with the valvematerials
Port sizes:
Mini G1/8 to G1/2
Standard G1/8 to G3
3-way G1/4 to G3/4
Gas approved G1/4 to G1
Operating pressure:
See individual details
Operating temperature:
Refer to table over the page
MATERIALSBody: nickel plated brass to UNI5705-65
Seats: virgin PTFE
Seals: virgin PTFE, FKM or nitrile
Ball: chromium plated brass
Handle with PVC grip: zinc platedsteel (plastic handle on mini ballrange)
PORT SIZESG1/8, G1/4, G3/8, G1/2, G3/4, G1,G11/4, G11/2, G2, G21/2, G3
BALL VALVES 60, 61, 62 Series
G1/8 to G3
H
C
D
G
B
G
B
ø S
Female Maximum MODELSpressure (bar)
Tee connector
B C D G H ØS kg
G1/8 36 22 9 19 5,5 19 10 0,078 601112118
G1/4 36 22 9 19 5,5 19 10 0,071 601112128
G3/8 41 24 9 19 8 21 10 0,086 601112138
G1/2 48 30 10 22 10 25 10 0,137 601112148
Female/male
G1/8 37 22 9 19 5,5 19 10 0,07 601112218
G1/4 37 22 9 19 5,5 19 10 0,06 601112228
G3/8 41 24 9 19 8 21 10 0,09 601112238
G1/2 48 30 10 22 10 25 10 1,30 601112248
6011: Light duty in-line brass ball valves suitable for a wide variety of low pressure industrial uses.
6018: Medium duty in-line brass exhausting ball valves. Venting action & lockout design adds safety feature to valve.
6021: Medium duty in-line brass ball valves for most applications. Available as a standard valve, a three way diverting valve or with a downstream exhaust option.
6041: Designed and certified to comply with the EN331 European norm covering gas ball valves.
6251: Heavy duty ball valve, two piece bar stock construction
General information
Symbol Type Application Materials Max. Temperature Thread MODELS body seats/seals pressure (bar) range standards
Mini General, light duty Brass PTFE & nitrile ‘O’ring 10 -10 to +90°C ISO 228/1 6011
Lockable General, with exhaust Brass PTFE 13,6 4 to 60°C ISO 228/1 6018
exhausting
Standard General purpose Brass PTFE & FKM ‘O’ring 10 to 45 -20 to +150°C ISO 228/1 6021
Three way General diverting Brass PTFE & nitrile ‘O’ring 16 to 25 -15 to +150°C ISO 228/1 6021
Exhausting General with exhaust Brass PTFE 40 to 64 -20 to +100°C ISO 228/1 6021
Standard Commercial gas and Brass PTFE 63 -15 to +120°C ISO 228/1 6041
general (5 for gas) (-20 to 60 for gas)
Standard Air & Low Pressure Carbon Steel RTFE 138 -30 to 220 ISO 228/1 6251
Hydraulic
12
1
2
10
12
13
2
10
12
1
2
10
12
13
2
10
12
13
2
10
12
1
2
10
12
1
2
10
ø S B
H
D
CLever handle - 625112*
FemaleBSPP
Maximum MODELSpressure (bar)
B C D ØS H
G1/4 50 41 10 96 25 140 625112128
G3/8 50 41 10 99 25 140 625112138
G1/2 63 43 13 96 32 140 625112148
G3/4 75 52 17 129 37 140 625112168
G1 88 58 22 129 44 140 625112188
To order ‘Tee’ handled version change 4th character to 2
Full bore
Maximum pressure (bar)Fluid Gas
MODELS
A B C D ØE ØF G kg
63 5 Rp1/4 41 49 35 8 23 85 18 0,116 604112128
63 5 Rp3/8 41 49,5 36 10 24 85 21 0,125 604112138
63 5 Rp1/2 44 61 44 15 32 85 26 0,210 604112148
63 5 Rp3/4 53 69,5 52 20 40 105 32 0,356 604112168
63 5 Rp1 57 84 56 25 48 105 39 0,585 604112188
63 5 Rp1 1/4 70 98 63 32 60 130 48 0,950 6041121A8
63 5 Rp1 1/2 76 108 69 40 72,5 130 55 1,400 6041121B8
63 5 Rp2 92 130 83 50 88 165 68 2,450 6041121C8
7-107
StandardFull bore
H
C
ø F
D
G
B
Female Maximum MODELSpressure (bar)
B C D ØF G H kg
G1/4 48 36 23 12 85 18 45 0,12 602112128
G3/8 49 36 24 12 85 21 40 0,13 602112138
G1/2 60 40 30 15 85 25 35 0,18 602112148
G3/4 69 47 38 16,5 105 31 30 0,32 602112168
G1 83 51 46 19 105 38 25 0,50 602112188
G1 1/4 96 63 58 21,5 130 47 20 0,88 6021121A8
G1 1/2 106 69 70 22 130 54 20 1,30 6021121B8
G2 129 83 86 25,5 165 66 20 2,17 6021121C8
G2 1/2 159 99 111 30 248 85 16 3,77 6021121D8
G3 182 110 135 33,5 248 100 10 5,84 6021121E8
For ‘Tee’ handled version change 4th digit to 2 ie.
602212128 for a 1/4" full bore tee handled ball valve.
Only up to 1" available with tee handle.
H
C
ø F
D
ø SB B 1
Female/Male
Maximum MODELSpressure (bar)
B C D ØF H ØS kg
G1/4 50 36 23 85 8 18 45 0,12 602112228
G3/8 54 36 24 85 10 21 40 0,14 602112238
G1/2 65 40 30 85 15 25 35 0,20 602112248
G3/4 75 47 38 105 20 31 30 0,35 602112268
G1 86 51 46 105 25 38 25 0,53 602112288
G1 1/4 99 63 58 130 32 47 20 0,93 6021122A8
G
C
øB
H
ø F
D
S
Female Maximum MODELSpressure (bar)
ExhaustingFull bore
B C D ØF H ØS kg
G1/4 52 61 29 100 8 22 64 0,25 602113128EX
G3/8 54 61 29 100 10 22 64 0,25 602113138EX
G1/2 69 64 36 100 15 27 50 0,37 602113148EX
G3/4 77 76 45 120 20 33 50 0,64 602113168EX
G1 89 80 54 120 25 40 50 0,89 602113188EX
G1 1/4 103 98 65 150 32 50 40 1,55 6021131A8EX
For ‘Tee’ handled version change 4th digit to 2 ie.602213128EX for a 1/4" full bore tee handled ball valve.
Three wayFull bore
115
ø F
J
D
38
5,5
9
ø 36
B
25
G
C
M 7
Female Maximum MODELSpressure (bar)
B C D ØF G J kg
G1/4 52 60 28 11 26 22 25 0,34 602114428
G3/8 52 60 28 11,5 26 22 25 0,28 602114438
G1/2 64 62 34,5 15 33,5 27 25 0,41 602114448
G3/4 74 43 43 16 39,5 32 16 0,60 602114468
Stainless steelball valves
H
C
ø F
ø S
D
B
FemaleBSPP
Maximum MODELSpressure (bar)
B C D ØS ØF H
Rp1/4 50 45 8 29 100 22 100 615112128
Rp3/8 50 45 10 29 100 22 100 615112138
Rp1/2 60 53,5 15 34 110 27 100 615112148
Rp3/4 70 64 20 42,5 140 32 100 615112168
Rp1 85 68 25 50,5 140 40 100 615112188
To order ‘Tee’ handled version change 4th character to 2
Lockable exhaustingFull bore C
7,5
H
D
ø SB
Female Maximum MODELSpressure (bar)
B C D H ØS kg
G1/4 44 45 93 8 20 13,6 0,17 601812128
G3/8 44 45 93 9 20 13,6 0,16 601812138
G1/2 58 50 93 14 24 13,6 0,24 601812148
G3/4 64 57 114 19 30 13,6 0,37 601812168
G1 81 61 114 24 40 13,6 0,62 601812188
Note: lever lockable only in closed position. Standardhandle accepts Ø 7 mm shackle.
G
C
ø F
D
ø EA
7-108 www.norgren.com/info/en7-108
For further information
Sliding sleeve operation
Very compact in-line units
Easy to install
Very simple and reliable operation
TECHNICAL DATAMedium:
Compressed air, filtered, lubricatedand non-lubricated
Operation:
Sleeve valve, directly actuated,with open exhaust
Mounting:
Concentrically directly in thepipework
Port sizes:
G1/8 M/7218
G1/4 M/7228
G3/8 M/7238
G1/2 M/7248
Operating pressure:
0 to 16 bar
Operating temperature:
-20°C to +80°C max.Consult our Technical Service for use below +2°C
MATERIALSBody: nickel plated brass
Sleeve: clear anodised aluminium
Seals: nitrile rubber
Port size Flow factor Flow 1 - 2 kg MODELSCv (l/min)
G1/8 0,7 678 0,05 M/7218
G1/4 1,3 1107 0,09 M/7228
G3/8 2,1 2035 0,16 M/7238
G1/2 3,2 3131 0,24 M/7248
Flow (l/min) 6 bar inlet, 1 bar pressure drop.
C
A
BØ
A B C MODELS
G1/8 25 48 14 M/7218
G1/4 30 58 17 M/7228
G3/8 35 68 22 M/7238
G1/2 40 80 27 M/7248
31
2
3/2 SLEEVE VALVES M/7200 Series Manually operated - G1/8 to G1/2
O/DTube
BSPTThread
MODELS O/DTube
BSPTThread
MODELS
C
E
ø 4,3
NB
C 1
G
ø O1
O
1
2 1
C
Eø 4,3
N B
G C2ø
A
ø O1
O
1
C
E
D
C 1
ø AN
ø O1
O
1
C
E
ø 4,3
2 1 NB
GC2
ø A
C 1
ø O1
O
1
7-024
PNEUFIT C COMPOSITE FITTINGSMetric Ø 4 to 16 mm O/D tube
SHUT-OFF VALVES
O/DTube
MODELS
3/2 Shut-off valves
3/2 Shut-off valves 3/2 Shut-off valves
ØA B C C1 C2 E G N O O1
6 R1/8 62 40,5 26 19 8 18,5 18 16,5 14 C01GH0618
6 R1/4 65 40,5 26 19 10 18,5 18 16,5 14 C01GH0628
6 R3/8 66 40,5 26 19 11 18,5 18 16,5 17 C01GH0638
8 R1/8 63 40,5 27,5 19 8 18,5 18 16,5 14 C01GH0818
8 R1/4 66 40,5 27,5 19 10 18,5 18 16,5 14 C01GH0828
8 R3/8 67 40,5 27,5 19 11 18,5 18 16,5 17 C01GH0838
10 R1/4 67 41 31 24 10 21,5 21 19,5 17 C01GH1028
10 R3/8 71,5 41 31 24 11 21,5 21 19,5 17 C01GH1038
10 R1/2 74,5 41 31 24 14 21,5 21 19,5 21 C01GH1048
12 R1/4 75,5 41 34 24 10 21,5 21 19,5 19 C01GH1228
12 R3/8 76,5 41 34 24 11 21,5 21 19,5 19 C01GH1238
12 R1/2 79,5 41 34 24 14 21,5 21 19,5 21 C01GH1248
ØA B C C1 C2 E G N O O1
6 R1/8 62 40,5 26 19 8 18,5 18 16,5 14 C01GJ0618
6 R1/4 65 40,5 26 19 10 18,5 18 16,5 14 C01GJ0628
6 R3/8 66 40,5 26 19 11 18,5 18 16,5 17 C01GJ0638
8 R1/8 65 40,5 27,5 19 8 18,5 18 16,5 14 C01GJ0818
8 R1/4 66 40,5 27,5 19 10 18,5 18 16,5 14 C01GJ0828
8 R3/8 67 40,5 27,5 19 11 18,5 18 16,5 17 C01GJ0838
10 R1/4 70,5 41 31 24 10 21,5 21 19,5 17 C01GJ1028
10 R3/8 71,5 41 31 24 11 21,5 21 19,5 17 C01GJ1038
10 R1/2 74,5 41 31 24 14 21,5 21 19,5 21 C01GJ1048
12 R1/4 75,5 41 34 24 10 21,5 21 19,5 19 C01GJ1228
12 R3/8 76,5 41 34 24 11 21,5 21 19,5 19 C01GJ1238
12 R1/2 79,5 41 34 24 14 21,5 21 19,5 21 C01GJ1248
ØA C C1 ØD E N O ØO1
6 52,5 40,5 4,3 19 18,5 18 16,5 C00GF0600
8 53 40,5 4,3 19 18,5 18 16,5 C00GF0800
10 62 41 4,3 24 21,5 21 19,5 C00GF1000
12 68,5 41 4,3 24 21,5 21 19,5 C00GF1200
1. Exhaustbore hole
1. Exhaustbore hole
1. Exhaustbore hole
1. Exhaustbore hole
O/DTube
MODELS
3/2 Shut-off valves
B C C1 E G N O O1
R1/8 71 40,5 19 8 18,5 18 16,5 14 C01GG1818
R1/4 77 40,5 19 10 18,5 18 16,5 14 C01GG2828
R3/8 81 41 24 11 21,5 21 19,5 17 C01GG3838
R1/2 90 41 24 14 21,5 21 19,5 21 C01GG4848
Allow free flow in one directiononly
Simple reliable design
Low weight
Low cracking pressure
High operating pressure
TECHNICAL DATAMedium:
Compressed air, filtered, lubricatedor nonlubricated, vacuum
Operating pressure:
-0,9 ... 16 bar
Cracking pressure:
0,03 ... 0,05 bar
O/D tube:
Ø 4, 6, 8, 10, 12 mm
Operating temperature:
-20°C ... +80°C max.Consult our Technical Service for use below +2°C
Tube types:
Nylon 11 or 12, polyurethane andother plasticised or unplasticisedtubing which conforms to thetolerances specified in BS 5409,Part 1, 1976, light and normalduty, DIN 73378, DIN 74234, NFE49-100
MATERIALSBody: aluminium
Grab ring: nickel plated brass
‘O’-ring: nitrile
4 0,4 0,23 0,1 0,09 96 0,010 T50P0004
6 1,45 0,36 0,36 0,31 349 0,016 T50P0006
8 2,9 0,3 0,7 0,62 699 0,022 T50P0008
10 5,1 0,35 1,25 1,09 1229 0,048 T50P0010
12 8,4 0,42 2,1 1,79 2024 0,064 T50P0012
Tube Flow factor Flow at 6 - 5 bar kg MODELSØmm C* b Cv Kv** ( l /min)
* Measured in dm3/ (s.bar)
** Measured in m3/ h
C
21 ø K
ø A
T50P0004 4 49 11
T50P0006 6 56,5 13
T50P0008 8 61 15
T50P0010 10 77,5 20
T50P0012 12 88,5 22
MODELS ØA C ØK
PIF NON-RETURN VALVES T50P Series O/D tube 4 to 12 mm
7-097www.norgren.com/info/en7-097
For further information
7-098 www.norgren.com/info/en7-098
For further information
Low cracking pressure
Releasable grab ring technologycombining plastic and brasscomponents for a compact andsuperior non-return design
Colour coding option withtamper-resistant feature
Non-PTFE based thread sealanton tapered threads
Moulded mounting brackets ontube connector designs (PIF/PIFplastic valves)
Red release sleeve indicatingmetric tube sizes for grab ringconnection
Grey release sleeve indicatinginch tube sizes for grab ringconnection
Reliable and corrosion resistant
TECHNICAL DATAMedium:
Compressed air, filtered,lubricated or nonlubricated,vacuum
Operating pressure:
0,1 to 10 bar (T51, T52)
0,3 to 10 bar (T53)
-0,1 to -1 bar vacuum (T51, T52)
Ambient temperature:
-20°C to +80°CConsult our Technical Service for use below +2°C
Mounting:
Tube/tube PIF
Tube PIF/male thread
Male thread/tube PIF
Tube types:
Nylon 11 or 12, polyurethane* andother plasticised or unplasticisedtubing which conforms to thetolerances specified in DIN
73378, BS 5409/1, NFE 49-100 &49-101, WD 16026, ISO/WD 16627
Copper and stainless steel* Suitable for 85D, polyurethane is light-stable
and has a hardness of 92 to 98 shore A
Note: O/D 5, 10, 12 mm, 3/16, 3/8,1/2" connections (collet instead ofgrab ring) are not suitable forcopper or stainless steel tubes, orsoft plastic tubing such as 85D
MATERIALS4, 6, 8 mm, 5/32, 1/4, 5/8 inch O/D:
Body: plastic PBT
Valve: plastic PBT
Release sleeve: plastic POM
Natural brass insert
Seal: silicon free nitrile
Spring: stainless steel
Grab ring: stainless steel, BS 1440Pt 2, grade 301.S21
T52 and T53 series, nickel platedbrass threads
5, 10, 12 mm, 3/16, 3/8, 1/2 inch O/D:
Collet: nickel plated brass
Body: black anodized aluminium
Valve and insert: aluminium
Tube size Flow factor Cracking Minimum operating kg PIF/PIF MODELSInch Metric C/CV* Kv pressure (bar) pressure (bar) ** Inch Metric
5/32" 4 mm 0,75/0,18 0,16 0,03+0,06 0,1 0,006 T51Y0002 T51P0004
3/16" 5 mm 1,16/0,28 0,25 0,03+0,06 0,1 0,018 T51Y0003 T51P0005
1/4" 6 mm 1,9/0,47 0,41 0,03+0,06 0,1 0,011 T51Y0004 T51P0006
5/16" 8 mm 3,5/0,86 0,75 0,03+0,06 0,1 0,013 T51Y0005 T51P0008
3/8" 10 mm 4,7/1,15 1 0,03+0,06 0,1 0,049 T51Y0006 T51P00010
1/2" 12 mm 7,5/1,84 1,6 0,03+0,06 0,1 0,066 T51Y0007 T51P00012
Port size x tube size Flow factor Cracking Minimum kg PIF Male/thread,NPTF x BSPT x C/CV* pressure operating Male thread/PIF MODELSinch metric Kv (bar) pressure (bar) ** Inch Metric Inch Inch Metric Metric
– M5 x4 mm 0,55/0,13 0,12 0,03+0,06 0,1 – 0,008 – – T52M0504 T53M0504
1/8x5/32" 1/8x4 mm 0,75/0,18 0,16 0,03+0,06 0,1 0,015 0,015 T52A1802 T53A1802 T52B1804 T53B1804
1/8x3/16" 1/8x5 mm 1,4/0,34 0,3 0,03+0,06 0,1 0,022 0,022 T52A1803 T53A1803 T52B1805 T53B1805
1/4x3/16" 1/4x5 mm 1,4/0,34 0,3 0,03+0,06 0,1 0,032 0,027 T52A2803 T53A2803 T52B2805 T53B2805
1/8x1/4" 1/8x6 mm 1,9/0,47 0,41 0,03+0,06 0,1 0,020 0,020 T52A1804 T53A1804 T52B1806 T53B1806
1/4x1/4" 1/4x6 mm 1,9/0,47 0,41 0,03+0,06 0,1 0,030 0,028 T52A2804 T53A2804 T52B2806 T53B2806
1/8x5/16" 1/8x8 mm 3,5/0,86 0,75 0,03+0,06 0,1 0,021 0,021 T52A1805 T53A1805 T52B1808 T53B1808
1/4x5/16" 1/4x8 mm 3,5/0,86 0,75 0,03+0,06 0,1 0,030 0,026 T52A2805 T53A2805 T52B2808 T53B2808
* C measured in dm3/(s.bar)
** Minimum operating pressure 0,3 bar for T53
T53
Tube/thread
T52
Tube/thread
T51
Tube/thread
PUSH-IN NON-RETURN VALVES T51, T52 and T53 SeriesIn-line - Ø 4, 6, 8, 10, 12 mm O/D tube
Ø 5/32", 3/16", 1/4", 5/16", 1/2" inch O/D tube
7-099
5/32 49,8 4,3 10,8 5,4 11,4 4 T51Y0002 T51P0004
3/16 53,1 4,3 13 6,7 13,6 5 T51Y0003* T51P0005*
1/4 55,3 4,3 13 6,7 13,6 6 T51Y0004 T51P0006
5/16 62,5 4,3 14,6 7,6 15,2 8 T51Y0005 T51P0008
3/8 77,4 – 20 – – 10 T51Y0006* T51P0010*
1/2 88,4 – 22 – – 12 T51Y0007* T51P0012*
A C D K H O A
ø K H
O
C
ø A ø
D
ø K
C
ø A
– – – – 10,8 12 49,2 4,3 4 M5 - - T52M0504 T53M0504
5/32 1/8 54,4 9,5 10,8 12 54,4 9,5 4 1/8 T52A1802 T53A1802 T52B1804 T53B1804
3/16 1/8 57,9 9,5 13 15 57,9 9,5 5 1/8 T52A1803* T53A1803* T52B1805* T53B1805*
3/16 1/4 62,7 14,3 13 15 59,4 11 5 1/4 T52A2803* T53A2803* T52B2805* T53B2805*
1/4 1/8 59,2 9,5 13 15 59,2 9,5 6 1/8 T52A1804 T53A1804 T52B1806 T53B1806
1/4 1/8 64 14,3 13 15 60,7 11 6 1/4 T52A2804 T53A2804 T52B2806 T53B2806
1/8 1/8 63,7 9,3 14,6 15 63,7 9,5 8 1/8 T52A1805 T53A1805 T52B1808 T53B1808
1/4 1/4 68,5 14,3 14,6 15 62,2 11 8 1/4 T52A2805 T53A2805 T52B2808 T53B2808
A B** C G K C G A B***
ø K B
G
C
ø A
C
B
G
ø K
ø A
Thread sealant is applied to the full circumference of the thread. Therecommended tightening torque figures for designs with thread sealant arefound in the torque table opposite
* O'Ring
* Available only with collet tube connection
MODELSInch Metric
MODELSInch Metric
T51
T52, T53
Thread (BSPT) Tightening torque (Nm)
1/8 6,86 ... 8,82
1/4 11,76 ... 13,72
3/8 21,56 ... 25,32
1/2 27,44 ... 29,40
*Available only with collet tube connection
**NPT according to ANSI-B1.20.1
***BSPT according to ISO 7/1M according to ISO.DIN 13
T53
Tube/thread
T52
Tube/thread
T51
Tube/thread
7-100 www.norgren.com/info/en7-100
For further information
M5 0,8 0,19 0,17 0,05 0,010 T55MO500
1⁄8 2,4 0,59 0,51 0,05 0,015 T55C1800 T55B1800 T55A1800
1⁄4 5,5 1,35 1,17 0,05 0,025 T55C2800 T55B2800 T55A2800
3⁄8 9,0 2,20 1,92 0,05 0,060 T55C3800 T55B3800 T55A3800
1⁄2 15,0 3,70 3,2 0,05 0,080 T55C4800 T55B4800 T55A480021
11 27,5 M5 5 4 10,5 3 12 T55MO500
14 42,5 1/8 NPT 7 7 13,5 4 15 T55A1800
17 54 1/4 NPT 10 8 16,5 5 18,5 T55A2800
24 63 3/8 NPT 13,5 9 23,5 7 26 T55A3800
27 77 1/2 NPT 13,5 12 26,5 10 30 T55A4800
14 42,5 R 1/8 7,5 7 13,5 4 15 T55B1800
17 54 R 1/4 11 8 16,5 5 18,5 T55B2800
24 63 R 3/8 11,5 9 23,5 7 26 T55B3800
27 77 R 1/2 15 12 26,5 10 30 T55B4800
14 42,5 G 1/8 7 7 13,5 4 15 T55C1800
17 54 G 1/4 10,5 8 16,5 5 18,5 T55C2800
24 63 G 3/8 12 9 23,5 7 26 T55C3800
27 77 G 1/2 15 12 26,5 10 30 T55C4800
B C D E ØF G ØH MODELS
T 55
Port size Flow factor Cracking pressure (bar)
kg MODELSMetricC* Cv BSPP BSPT NPT
*C: measured in dm3/(s.bar)**: measured in m3/h
Kv**
E
B
G
ØF
D
C
ØH
M5 0,55 0,19 0,12 0,05 0,018 T56MO500
1⁄8 2,4 0,59 0,51 0,05 0,045 T56C1800 T56B1800 T56A1800
1⁄4 5,0 1,23 1,07 0,05 0,072 T56C2800 T56B2800 T56A280021
T 56
Port size Flow factor Cracking pressure (bar)
kg MODELSMetricC* Cv BSPP BSPT NPT
*C: measured in dm3/(s.bar)**: measured in m3/h
Kv**
11 31,5 M5 5 4 10,5 3 12 4,5 T56MO500
14 49 1/8 NPT 7 4,5 13,5 4 15 9,5 T56A1800
17 62,5 1/4 NPT 10 5 16,5 5 18,5 14,5 T56A2800
14 49 R 1/8 7,5 4,5 13,5 4 15 9,5 T56B1800
17 59 R 1/4 11 5 16,5 5 18,5 11 T56B2800
14 45 G 1/8 7 4,5 13,5 4 15 5,5 T56C1800
17 56 G 1/4 10,5 5 16,5 5 18,5 8 T56C2800
B C D E ØF G ØH I MODELSEI
B
G
ØF
D
CC
ØH
NON-RETURN VALVES T55/T56 Series In-line - M5, 1/8 to 1/2 inch - Metric, BSPP, BSPT or NPT
Permit free flow of air in onedirection only
Simple, reliable design
Light weight
Silicone free
Low cracking pressure
O-ring in the parallel threads T56series
TECHNICAL DATAMedium:
Compressed air, filtered, lubricatedand non-lubricated
Operating pressure:
0,1 to 10 bar
Ambient temperature:
-20°C to +80°CConsult our Technical Service for use below +2°C
MATERIALSBody: aluminium (T55), brass (T56)
O-ring: silicone free nitrile
Valve: POM
Spring: stainless steel
21
7-101www.norgren.com/info/en7-101
For further information
Allows free flow in one directiononly
Simple reliable design
High operating pressure andtemperature
Spares kit available
TECHNICAL DATAMedium:
Compressed air, filtered, lubricatedor nonlubricated, vacuum
Operating pressure:
0,3 to 16 bar
Ambient temperature:
-20°C to +80°CConsult our Technical Service for use below +2°C
MATERIALSBody: brass
O-ring: nitrile rubber
Valve: aluminium
Note: FKM seals for hightemperature version
ALTERNATIVE MODELSAlternative range of NPT areavailable. Consult our TechnicalService for details.
HEAVY DUTY NON-RETURN VALVES S/520 Series G1/8, G 1
Port size Port size Flow factor Cracking kg MODELS Spare kitBSPP C* Cv Kv** Pressure (bar)
G1/8 1/8 2,4 0,6 0,51 < 0,1 0,04 S/520 QS/520/00
G1/4 1/4 4,3 1 0,92 < 0,1 0,09 S/521 QS/521/00
G3/8 3/8 10,5 2,6 2,24 < 0,1 0,14 S/532 QS/532/00
G1/2 1/2 17 4,2 3,62 < 0,1 0,21 S/522 QS/522/00
G3/4 3/4 42 10,3 8,95 < 0,1 0,55 S/523 QS/523/00
G1 1 65 16 13,85 < 0,1 1,1 S/524 QS/524/00
For high temperature (150°C+) versions, insert ‘T’ in front of model code e.g. TS/520
For NPT ranges, substitute C at the 1st digit e.g. C/520
C*: Measured in dm3/ (s.bar)
Kv**: Measured in m3/ h
D E
B
CC
A
‘1’ ‘2’
A B C D E MODELS
14 43 1/8 10 10 S/520
19 48 1/4 11 11 S/521
22 62 3/8 13 13 S/532
27 76 1/2 17 17 S/522
36 92 3/4 18 18 S/523
49 124 1 25 25 S/524
7-102 www.norgren.com/info/en7-102
For further information
1
2
3
1
2
3
1
2
3
Enables air to be exhaustedquickly from air reservoirs andcylinders
Allows higher cylinder speeds tobe achieved
Simple, compact design andconstruction
Very reliable in operation
TECHNICAL DATAMedium:
Compressed air, filtered,lubricated or nonlubricated,vacuum
Operating pressure:
0,5 ... 10 bar (T70)
0,7 ... 10 bar (S/511)
0,7 ... 7 bar (S/513, S/514)
Ambient temperature:
-20°C to +80°CConsult our Technical Service for use below +2°C
Mounting:
In line mounted
MATERIALST70:
Body and Cover: Aluminium orzinc alloy
Seals: Nitrile rubber
S/511, S/513, S/514:
Cover: aluminium (S/511), plasticPOM (S/513, S/514)
Silencer shell: plastic POM (S/513,S/514)
Cup seal: polyurethane
O’ring: nitrile
Element: porous plastic (S/513, S/514)
T 70Flow from 1-2 MODELS Spare kit
Port size *3) Flow factor 1 - 2 Flow factor 2- 3 at 6-5 barInlet Outlet Exhaust C*1) Cv Kv *2) C*1) Cv Kv *2) (l /min) kg
G1/8 G1/8 G1/8 3,8 0,93 0,81 7 1,72 1,49 837 0,15 T70C1800K0 T70C1800
G1/4 G1/4 G1/4 7,4 1,8 1,58 9,7 2,38 2,07 1289 0,13 T70C2800K0 T70C2800
G3/8 G3/8 G3/8 14,5 3,55 3,1 20,5 5 4,37 2656 0,21 T70C3800K0 T70C3800
G1/2 G1/2 G1/2 19,7 4,83 4,2 25 6,13 5,33 3101 0,19 T70C4800K0 T70C4800
G1/2 21,6 5,3 4,6 2022 39 9,56 8,3 NO 0,31 S/511 QS/511/00
G1/4 7,6 1,86 1,62 900 13,5 3,3 2,9 YES 0,25 S/513 QS/510/00
G1/2 5,3 5,3 4,6 2022 39 9,56 8,3 YES 0,35 S/514 QS/511/00
Port size 1 Flow (1 to 2) Flow at 6- 5 bar Flow (2 to atm) Silencer at kg MODELS Spare kitC *1) Cv Kv *2) (l /min) C *1) Cv Kv *2) exhaust port (seals only)
S/511, S/513, S/514
QUICK EXHAUST VALVES T70, S/511, S/513, S/514 Series 1/8 to 1/2" BSPP
*1) Measured in dm3/ (s.bar)*2) Measured in m3/ h*3) For NPT version, please change substitute C into A at the 4th digit, e.g. T70A1800
*1) Measured in dm3/ (s.bar)*2) Measured in m3/ h
øB
øJ
K
F
A
H
D
A
AG
1
1
33
1
7-103
A ØB D F G H ØJ K 1 MODELS
G1/8 19 28 15,5 3,5 53 29 35,5 19 30 T70C1800
G1/4 19 28 15,5 3,5 53 29 35,5 19 30 T70C2800
G3/8 30 40 15,5 4 73,5 46 48 30 46 T70C3800
G1/2 30 40 15,5 4 73,5 46 48 30 46 T70C4800
Characteristic curvesChoked flow versus inlet pressureWay (1 - 2) + (2 - 3)
1 2 3 4 5 6 7 8 9 1000
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
2 - 3
1 - 2
1 2 3 4 5 6 7 8 9 1000
10
20
30
40
50
60
70
80
90
100
110 2 - 3
120
1 - 2
1 2 3 4 5 6 7 8 9 1000
20
40
60
80
100
120
140
160
180
200
220
240 2 - 3
1 - 2
1 2 3 4 5 6 7 8 9 1000
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
2 - 3
1 - 2
T 70
ØL
M
E
F
D
G A
K
B H
J
C
1
32
1
2
A B C D E F G H J K ØL M 1 2 MODELS
G1/2 G3/4 G3/4 100 86 50 28,5 35 36 48 17 47,5 15,0 32 30 S/511
S/511
ØL
E
F
1
D
G A
K
B H
J1
2
3
A B C D E F G H J K ØL ØO 1 MODELS
G1/4 G3/8 47,5 58 86,5 29 18,0 23 23 23 10 34,0 34 21 S/513G1/2 G3/4 63,0 100 134,0 50 28,5 35 36 48 17 47,5 59 30 S/514
S/513, S/514
Inlet pressure (bar)
Ch
oke
d f
low
l/s
T70.1800
Inlet pressure (bar)
Ch
oke
d f
low
l/s
T70.2800
Inlet pressure (bar)
Ch
oke
d f
low
l/s
T70.3800
Inlet pressure (bar)
Ch
oke
d f
low
l/s
T70.4800
For NPT ranges, substitute C at the first digit, e.g. C/511
7-104 www.norgren.com/info/en7-104
For further information
1
2
3
High flow rate from A to R
Low min. pressure
Compact design
Simple construction
Also suitable as two-way valveor double check valve
TECHNICAL DATAMedium:
Compressed, filtered, lubricated ornon-lubricated air
Operating pressure:
0,5 to 10 bar
Ambient temperature:
-20°C to +80°C max.
MATERIALSBody: Brass, nickel-plated
Cover: Brass, nickel-plated
Moulded part: PUR
QUICK EXHAUST VALVES 4050 SeriesG 1/8 to G 1
B C E F ØH Flow rate (l/min)* kg MODELS1 to 2 2 to 3
G1/4 65 24 25,5 34 19 850 2160 0,18 4050214
G1/2 82 30 33 44 32 2160 5700 0,43 4050314
G1 109 48 39 80 46 3400 12500 1,76 4050514
F
2
C
E
B
1
3
ø H
*At 6 bar with 1 bar pressure drop
111
2
7-105www.norgren.com/info/en7-105
For further information
Allow two independent signalsources to be connected to acommon pilot line
Can be used to perform an 'OR'logic function
Can be combined to operate fromthree or more sources
Valves can be ganged together
TECHNICAL DATAMedium:
Compressed air, filtered, lubricatedor non-lubricated, inert gas
Port size:
G1/8 (T65C1800)
G1/4 (T65C2800)
Operating pressure:
0,7 ... 10 bar
Operating temperature:
-20°C ... +80°CConsult our Technical Service for use below +2°C
MATERIALSBody: zinc alloy
Ball: nitrile
Valve seat: brass
G 1/8 1,7 0,42 0,364 412 0,055 T65C1800
G 1/4 2,6 0,64 0,56 631 0,130 T65C2800
Port Flow factor Flow at kg MODELS*3)size 6 - 5 bar
C *1) Cv Kv *2) (l/min)
N
ØH
G
M
LK
F
A
1 1
2
A F G ØH K L M N MODELS
G 1/8 15 20 5,25 6 10 25 36 T65C1800
G 1/4 20 25 5,25 8 12 30 50 T65C2800
SHUTTLE VALVE ('OR' LOGIC FUNCTION) T65C Series G1/8 & G1/4
*1) Measured in dm3/ (s.bar)*2) Measured in m3/ h*3) For NPT ranges, substitute A at the digit C, e.g. T65A1800.
7-111www.norgren.com/info/en7-111
For further information
BG4000:
Bright chrome finish
Cushioned corporate vinyl thumbgrip
Exhausts air when nozzle isblocked
Complies with O.S.H.A.
BG5000:
One piece design in moulded highimpact plastic
Exhausts air when nozzle isblocked
Complies with O.S.H.A.
TECHNICAL DATAMedium:
Non-lubricated compressed air,filtered
Connection:
G1/4 (BG4000 and BG5000)
Operating pressure:
10 bar maximum line pressure
The USA O.S.H.A. recommendations state thatnozzle pressures should not exceed 2 bar. Thisensures that the blocked end condition pressurewill not exceed the 0,4 bar that could penetratehuman skin with possibly fatal consequences.Blow guns should always be supplied through asuitable pressure regulator to ensure safe operation
COMPLIMENTARYPRODUCT2 bar, G1/4 pre-set pressureregulator
Part number: R16-200-R30D
BLOW GUNS BG SeriesRc1/4, G1/4
110
G1/
4
60
1/8
x 27
NP
T
BG4000
195
146
10
G1/4
BG5000
Accessories for BG4000
45
12,5
1/8
x 27
NP
T
Safety booster BG0100
163 (BG0106), 315 (BG0112)
1/8
x 27
NP
T
8
12,7 (A/F)
Extension tubes BG0106, BG0112
Size MODELS
G1/4 BG4000
G1⁄4 BG5000
7-112 www.norgren.com/info/en7-112
For further information
Assists in complying with safetyregulations
Tamper proof
Compact and safe design
Low pressure drop
Automatically resets after failurecorrection
High corrosion resistance
High air pressure rating
TECHNICAL DATAMedium:
Compressed air, filtered,lubricated and non lubricated inertgases
Operating pressure:
Maximum 16 bar
Minimum according to hose length
Ambient temperature:
-20°C to +80°CConsult our Technical Service for use below +2°C
Mounting:
In-line two way valve. To beinserted between fixed air supplyand flexible hose air line. Seeguidelines for typical installation.
MATERIALSBody: aluminium
Internal parts: brass
Spring: stainless steel
AIR FUSES In-line excess flow shut-off valves1/4 to 1 1/2” BSPP
1/4 0,14 8,3 6,5 0,041 T60C2890
1/4 0,3 14 6,5 0,041 T60C2891
3/8 0,14 19,4 13,5 0,065 T60C3890
3/8 0,3 32,2 13,5 0,065 T60C3891
1/2 0,14 32,2 23,2 0,150 T60C4890
1/2 0,3 48,3 23,2 0,150 T60C4891
3/4 0,14 48,3 43 0,130 T60C6890
3/4 0,3 80 43 0,130 T60C6891
1 0,14 92 68 0,540 T60C8890
1 0,3 128 68 0,540 T60C8891
1 1/2 0,14 186 145 1,1 T60CB890
1 1/2 0,3 268 145 1,1 T60CB891
Function Port sizeBSPP
Drop pressure atshut off flow (bar)
Shut off flow rate at 7 bar (dm3/s) ±10%
Flow at 7 bar kgΔ P 0,07 bar (dm3/s)
MODELS
21
Ø T60C289* T60C389* T60C489* T60C689* T60C889* T60CB89*BSPP BSPP BSPP BSPP BSPP BSPP
B
C
DD
C
A
F
E
**
**
**
**
**
**
*
*
*
*
*
*
�
Guidelines for typical installation
The air fuse should be installed directly between fixed or rigid pipework and the flexible tube toprotect the whole length of the flexible tube. Only tubing after the air fuse is protected. The air fusemust be installed in the correct direction for airflow. Failure to do this will render the air fuseineffective. When a shut-off valve is located before the air fuse, the valve must be opened slowlyin order to control initial air flow and avoid decompression effects which may trip the air fuse.
Air
su
pp
ly
Rigid line Flexible line
A a/f 20,6 24 31,75 31,75 50,8 63,5
B 51 62 78 90 118 145
C 1/4 3/8 1/2 3/4 1 1 1/2
D 11 14 15 19 25,5 25,5
E 3 5 5 5 5 5
F 20,6 24 31,75 31,75 50,8 63,5
* Last digit depends on flow range. For NPT ranges, substitute A at digit C, e.g. T60A289*
BSPP: according to BS2779 and ISO 228/1.Flow and pressure test conducted according to ISO 6358 test circuit. Mean measured flow values are provided at standard reference conditions.
7-113
How to select an air fuse
a) The port size of the air fuse should be nominally equal to that of thesupply lines e.g. a 1⁄2'' (12,7mm) air fuse should be used with a 1⁄2''(12,7mm) ID hose.
b) Always select the high flow model (91) if there is sufficient systempressure for the length of hose to be protected. See tables hose length vsminimum supply pressure.
c) If there is insufficient system pressure, or long hose lengths are to beprotected, use model 90.
d) After installation always test each valve for proper function. See sectionhow to check an air fuse below.
e) The pneumatic system must be capable of delivering the flow required toactivate the air fuse.
f) For use with spring coils consult table. See table flow vs pressure supply.
How to check an air fuse
* Install air fuse following the instructions supplied
* Connect tool or complete circuit to the air line
* Switch on operation to ensure a complete cycle isperformed
* If tool or complete circuit starts and runs satisfactorily,stop operation and drain air line. Disconnect hose fromtool or circuit and secure hose end. Turn on air supplyprogressively (to avoid decompression effect). Prior tofully reaching operation conditions, the valve shouldsuddenly activate and cut off the flow. A slight air flowwill remain as part of the automatic re-set function. If theair fuse is not activated the unit should be disconnectedand the lower flow range air fuse should be used.
T60C2890 T60C2891 T60C3890 T60C3891 T60C4890 T60C4891
Note: Where no figure is shown these spring coils cannot be protected by the air fuse
PA330600328
PA330600428
PA330600528
PA330600828
PA330601528
PA330800328 4,1
PA330800428 5,4
PA330800528
PA330800828
PA330801528
PA331000328 1.0 2,5 4,8
PA331000428 1,2 3,3 6,4
PA331000528 1,5 4,2
PA331000828 2,2 6,2
PA331001528 4,4
PA331200338 0,7 0,9 1,5 4,1
PA331200438 0,7 1,0 2,0 5,4
PA331200538 0,7 1,3 2,4
PA331200838 0,7 1,9 3,7
PA331201538 1,4 3,8
PA331500348 0,7 0,9 0,7 1,5 1,5 3,5
PA331500448 0,7 0,9 0,7 2,1 2,1 4,6
PA331500548 0,7 0,9 0,9 2,6 2,6 5,8
PA331500848 0,7 0,9 1,4 3,8 3,8
PU310600218
PU310600418
PU310600618
PU310600818
PU310800228 5,4
PU310800428
PU310800628
PU310800828
PU311000228 1,3 3,8
PU311000428 2,7
PU311000628 5,0
PU311000828 6,0
PU311200238 0,7 1,2 2,4 6,6
PU311200438 0,9 2,5 4,8
PU311200638 1,3 3,7
PU311200838 1,6 4,6
Spring coils and air fuse minimum required pressure (bar)
Spring coils Air fuse
7-114
AIR FUSES In-line excess flow shut-off valves1/4 to 1 1/2” BSPP
Hose length vs minimum pressure supply (1/4" ... 3/8")
Hose length vs minimum pressure supply (1/2" ... 3/4")
Hose length vs minimum pressure supply (1" ... 1 1/2")
450
400
350
300
250
200
150
100
50
01 2 3 4 5 6 7 8 9 10 1112 13 141516
78
9
10
6
11
— 6 - T60 * 6890
— 7 - T60 * 6891
— 8 - T60 * 8890
— 9 - T60 * 8891
— 10 - T60 * B890
— 11 - T60 * B891
— 1 - T60 * 2890
— 2 - T60 * 2891
— 3 - T60 * 3890
— 4 - T60 * 3891
— 4 - T60 * 4890
— 5 - T60 * 4891
1 - T60 * 2890 (ID = 6,6mm)
2 - T60 * 2891 (ID = 6,6mm)
3 - T60 * 3890 (ID = 9,0mm)
4 - T60 * 3891 (ID = 9,0mm)
— 9 - T60 * 8890 (ID = 25,4mm)
— 10 - T60 * 8891 (ID = 25,4mm)
— 11 - T60 * B890 (ID = 38,1mm)
— 12 - T60 * B891 (ID = 38,1mm)
5 - T60 * 4890 (ID = 13mm)
6 - T60 * 4891 (ID = 13mm)
7 - T60 * 6890 (ID = 19mm)
8 - T60 * 6891 (ID = 19mm)
60
55
50
45
40
35
30
25
20
15
10
5
01 2 3 4 5 6 7 8 9 10 1112 13 141516
65
70
1
2
3
4
5
75
12
11
10
9
8
7
6
5
4
3
2
1
00 1 2 3 4 5 6 7 8 9 10
13
14
1
2
3
4
6
5.5
5
4.5
4
3.5
3
2.5
2
1.5
1
0.5
00 � 2 4 � 6 8 10 12 14 16 18 20
6.5
7
7
5
8
6
7.5
8
9
10
11
12
3
�
2.5
�
2
�
1.5
�
1
�
0.5
�
00 � 2 4 � 6 8 10 12 14 16 18 20
�
3.5
�
�
Measurements
Flow and pressure tests conducted according to ISO-6358 test circuit
Mean measured flow values are provided at standard referencecondition (20°C, 1,01 bar).
Indicated pressure values are relative pressure in bar.
Hose lengths
Graphs are for indicated hose internal diameter in key.
Consult our Technical Service for hose lengths and internal diametersdifferent from the recommended one.
Minimum pressure required to shut off the air supply – check failure flow conditions
Flow (±10%) vs pressure supply (1/4 ... 1/2”)
Flow (±10%) vs pressure supply(3/4 ... 11/2”)
Flow required to shut off air supply – check normal flow conditions
Pre
ssu
re s
up
ply
(b
ar)
Pressure supply (bar) Pressure supply (bar)
Pre
ssu
re s
up
ply
(b
ar)
Pre
ssu
re s
up
ply
(b
ar)
Hose length (m)
Sh
ut
off
flow
(d
m3 /
s)
Sh
ut
off
flow
(d
m3 /
s)
Hose length (m) Hose length (m)
7-115
G 1/8 0,46 04 0431 02 000
Eliminates unwanted signals
Cannot duplicate a signal
Simple, reliable operation
TECHNICAL DATAMedium:
Compressed air, filtered, lubricatedand non-lubricated
Operation:
Piston valve, directly actuated
Mounting:
Through-holes in lugs on valvebody
Port Size:
G1/8
Operating Pressure:
2 - 10 bar
Signal Output Pressure:
90% input pressure
Impulse Duration:
0,2 - 0,4 ms
Operating Temperature:
-20°C* to +80°C
Consult our Technical Service for use below +2°C.
MATERIALZinc alloy body and top cover,brass piston, nitrile rubber seals
IMPULSE GENERATOR3/2 Piston Valve
G1/8
Size kg MODELS
Typical Performance Characteristics
Performance (basic unit)
2 3 4 5 6 7 8 9 100
1
2
3
4
5
Sec
ond
s
Pressure-bar
Total cycle time
Recovery time
Pulse time
Improved reset time circuit
Important: Under no circumstances should thebleed orifice in the piston be modified in an attemptto obtain a different impulse duration. To obtain alonger duration, connect a separate air reservoir tothe port in the top of the unit. To reduce the resettime, fit a non-return valve into the circuit as shownbelow. For any working conditions outside thosequoted, consult our Technical Service.
To reduce the reset or recovery time of the
generator, a non-return valve can be fitted in the
circuit as shown.
11
79
G 18/
50
53
5�
51
67
Impulse Generator
Auxiliary port plugged
Exhaust - do
not obstructINLET
The Impulse Generator is fitted
between a trip valve and directional
control valve when it is necessary to
eliminate a trapped or locked pilot
signal which would otherwise prevent
the control valve from resetting. When
an input signal is applied, it generates
a short duration output signal which is
then automatically exhausted. A
further output signal cannot be
generated until the input signal has
been removed.
The downstream volume should not
exceed 0,033 dm which is equivalent
to approximately 6,67 metres of 4 mm
o.d. nylon tube.
www.norgren.com/info/en7-115
For further information
7-116 www.norgren.com/info/en7-116
For further information
Pressure 1/4 04 0161 00
Vacuum 1/4 04 0162 00
1/8 04 0174 00
1/4 04 0175 00
3/8 04 0176 00
For use with a variety of fluids
7 bar maximum
50 r.p.m. maximum
SLOW ROTATING JOINTS
Pressure and vacuum models
For use with a variety of fluids
7 bar maximum
2000 r.p.m. maximum
FAST ROTATING JOINTS
BSPT Taper MODELS
Medium BSPT Taper MODELS
ADDITIONAL RANGES